Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1355 CYNTHIA LN; ; FPR2023-0083; Permit
Atz (City of Carlsbad "- 1111" Fail k Print Date: 05/01/2025 Job Address: 1355 CYNTHIA IN, CARLSBAD, CA Permit Type: FIRE-Construction Residential Parcel #: 1562317000 Valuation: $523,378.08 Occupancy Group: #f Dwelling Units: Bedrooms: Bathrooms: Work Class: Track #: Lot #: Project #: DEV2022-0043 Plan #: Construction Type: Orig. Plan Check #: Plan Check#: Permit No: FPR2023-0083 Applied: 12/19/2023 Issued: 01/04/2024 Finaled Close Out: 02/03/2025 Final Inspection: INSPECTOR: Cheung, Nathaniel Status: Closed - Finaled Single Family Fire Sprinki Project Title: HAGUE RESIDENCE Description: HAGUE RESIDENCE -INSTALLATION OF NEW 13D SPRINKLER SYSTEM (43 HEADS) Applicant: FPContractor: VANGUARD FIRE PROTECTION INC VANGUARD FIRE PROTECTION INC MICHAEL HICKMAN PO BOX 1300 2030 ALESSANDRO TRL VISTA, CA 92085-1300 VISTA, CA 92084-4220 (760) 727-8540 (760) 727-8540 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $157.00 FIRE NFPA 13D Single Family System (Plan Review) $310.00 Total Fees: $467.00 Total Payments To Date: $467.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov - Fife Protection by Computer Design VANGUARD FIRE PROTECTION INC P0 BOX 1300 VISTA, CA 92085 760-727-8540 Job Name : HAGUE RESIDENCE Building Location System Contract Data File : 23-131 HAGUE RES - 1 HD 15x15.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 VANGUARD FIRE PROTECTION INC Page 1 HAGUE RESIDENCE Date 11/12/2023 HYDRAULIC CALCULATIONS for Project name: HAGUE RESIDENCE Location: Drawing no: Date: 11/12/2023 Design Remote area number: Remote area location: BED Occupancy classification: RES Density: .05 - Gpm/SqFt Area of application: I HEAD - SqFt Coverage per sprinkler: 15x 15 - SqFt Type of sprinklers calculated: SENJU (SS8261) 3.7K 1/2" CONCEALED PENDENT No. of sprinklers calculated: 0 In-rack demand: - GPM Hose streams: 5-GPM Total water required (including hose streams): 17 - GPM © 33.71 -Psi Type of system: WET Volume of dry orpreaction system: -Gal Water supply information Date: 11/7/2023 Location: 1368 CYNTIA LN Source: CARLSBAD WATER DEPT Name of contractor: VANGUARD FIRE PROTECTION INC Address: P0 BOX 1300/ I VISTA, CA 92085 Phone number: 760-727-8540 Name of designer: J. BALCH Authority having jurisdiction: CARLSBAD FIRE DEPT. Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C VANGUARD FIRE PROTECTION INC Page 2 HAGUE RESIDENCE Date 11/12/2023 City Water Supply: Demand: Cl - Static Pressure : 49 Dl - Elevation : 10.143 C2 - Residual Pressure: 39.5 D2 - System Flow C2 - Residual Flow : 500 D2 - System Pressure : 33.709 Hose (Demand) :17 D3 - System Demand :17 Safety Margin : 15.273 150 140 130 p 12 R110 E100 90 80 u 70 R6° Cl 40 E5° D2 30 133 20 10 •- ..... .... .. -.....-. .. 50 100 150 200: 250 300 350 400 450 FLOW (NA 1.85) C2 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary VANGUARD FIRE PROTECTION INC Page 3 HAGUE RESIDENCE Date 11/12/2023 Fitting Legend Abbrev. Name 1/2 % 1 1~ 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 Ball B Ball MIIW BB-SCIOO 2.25 2 2.5 2.25 10 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90 Flow thru lee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD VANGUARD FIRE PROTECTION INC Page 4 HAGUE RESIDENCE Date 11/12/2023 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 21.42 10.78 na 2 21.42 10.78 na 3 21.42 10.5 na 12.0 Al 21.42 10.78 na A2 21.42 10.78 na A3 21.42 11.46 na A4 21.42 11.67 na B4 10.92 16.63 na B5 10.92 17.71 na TR 10.92 18.28 na BR 2.5 25.4 na 5.0 Ui -2.0 28.29 na MTR -2.0 29.77 na SRC -2.0 33.71 na The maximum velocity is 7.01 and it occurs in the pipe between nodes MTR and SRC Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams - 2007 VANGUARD FIRE PROTECTION INC Page 5 HAGUE RESIDENCE Date 11/12/2023 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 1 0.0 1.101 R 1.0 9.750 10.784 to 150.0 0.0 1.000 0.0 2 0.0 0.0 0.0 10.750 0.0 Vel = 0 2 0.0 1.101 0 5.0 0.660 10.784 to 150.0 0.0 5.000 0.0 Al 0.0 0.0 0.0 5.660 0.0 Vel =0 0.0 0.0 10.784 K Factor = 0 3 12.00 1.101 0 5.0 5.750 10.500 Qa = 12 to 150.0 0.0 5.000 0.0 A2 12.0 0.0264 0.0 10.750 0.284 Vel = 4.04 0.0 12.00 10.784 K Factor = 3.65 ** Al 0.0 1.101 2R 2.0 8.420 10.784 to 150.0 0.0 2.000 0.0 A2 0.0 0.0 0.0 10.420 0.0 Vel = 0 A2 12.00 1.101 3R 3.0 17.420 10.784 to 150.0 0 5.0 8.000 0.0 A3 12.0 0.0264 0.0 25.420 0.672 Vel = 4.04 A3 0.0 1.101 N 7.0 1.160 11.456 to 150.0 0.0 7.000 0.0 A4 12.0 0.0265 0.0 8.160 0.216 Vel = 4.04 A4 0.0 1.101 0 5.0 10.500 11.672 to 150.0 0.0 5.000 4.548 B4 12.0 0.0265 0.0 15.500 0.410 Vel = 4.04 B4 0.0 1.101 20 10.0 29.870 16.630 to 150.0 R 1.0 11.000 0.0 B5 12.0 0.0264 0.0 40.870 1.081 Vel = 4.04 B5 0.0 1.101 R 1.0 13.500 17.711 to 150.0 N 7.0 8.000 0.0 TR 12.0 0.0264 0.0 21.500 0.568 Vel = 4.04 TR 0.0 1.101 Fsp 0.0 8.420 18.279 to 150.0 S 9.563 9.562 6.647 * Fixed Loss = 3 BR 12.0 0.0264 0.0 17.982 0.475 Vel = 4.04 BR 5.00 1.025 3E 8.1 5.000 25.401 Qa=5 to 150.0 0.0 8.100 1.949 UI 17.0 0.0714 0.0 13.100 0.935 Vel = 6.61 UI 0.0 1.36 3E 12.666 70.000 28.285 to 150.0 0.0 12.667 0.0 MTR 17.0 0.0180 0.0 82.667 1.489 Vel = 3.75 MTR 0.0 0.995 Ball 2.628 15.000 29.774 to 150.0 T 5.841 8.469 2.000 * Fixed Loss = 2 SRC 17.0 0.0824 0.0 23.469 1.935 Vel = 7.01 0.0 33.709 K Factor = 2.93 Computer Programs by Hydratec Inc. Revision: 50.52.1 - Fire Protection by Computer Design VANGUARD FIRE PROTECTION INC P0 BOX 1300 VISTA, CA 92085 760-727-8540 Job Name : HAGUE RESIDENCE Building Location System Contract Data File : 23-131 HAGUE RES -2 HD 14x14.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 VANGUARD FIRE PROTECTION INC Page 1 HAGUE RESIDENCE Date 11/12/2023 HYDRAULIC CALCULATIONS for Project name: HAGUE RESIDENCE Location: Drawing no: Date: 11/12/2023 Design Remote area number: Remote area location: M. BED Occupancy classification: RES Density: .05 - Gpm/SqFt Area of application: 2 HEAD - SqFt Coverage per sprinkler: 14x14 - SqFt Type of sprinklers calculated. SENJU (SS8261) 3.7K 1/2" CONCEALED PENDENT No. of sprinklers calculated: 0 In-rack demand: - GPM Hose streams: 5-GPM Total water required (including hose streams): 25- GPM @ 42.44 -Psi Type of system: WET Volume of dry or preaction system: -Gal Water supply information Date: 1117/2023 Location: 1368 CYNTIA LN Source: CARLSBAD WATER DEPT Name of contractor VANGUARD FIRE PROTECTION INC Address: P0 BOX 1300/ I VISTA, CA 92085 Phone number: 760-727-8540 Name of designer: J. BALCH Authority having jurisdiction: CARLSBAD FIRE DEPT. Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C VANGUARD FIRE PROTECTION INC Page 2 HAGUE RESIDENCE Date 11/12/2023 City Water Supply: Demand: Cl -Static Pressure : 49 Dl - Elevation : 10.143 C2 - Residual Pressure: 39.5 D2 - System Flow C2 - Residual Flow : 500 D2 - System Pressure : 42.443 Hose ( Demand) : 25 D3 - System Demand : 25 Safety Margin : 6.519 150 140 130 p120 R0 E100 S90 S80 u 70 R6° Cl E50 •D7 40 __________ ________ 30D 20 10 5F .I I I I I 50 100 150 200 250 300 350 400 450 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 C2 Fittings Used Summary VANGUARD FIRE PROTECTION INC Page 3 HAGUE RESIDENCE Date 11/12/2023 Fitting Legend Abbrev. Name 1/2 ~ 1 1% 11/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 Ball B Ball Milw BB-SCIOO 2.25 2 2.5 2.25 10 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N CPVC9O'EllHarvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and C Factors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD VANGUARD FIRE PROTECTION INC Page 4 HAGUE RESIDENCE Date 11/12/2023 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 21.42 7.3 na 10.0 2 21.42 7.5 na 10.0 3 21.42 8.6 na Al 21.42 7.89 na A2 21.42 8.6 na A3 21.42 10.33 na A4 21.42 10.88 na 84 10.92 16.48 na 85 10.92 19.26 na TR 10.92 20.73 na BR 2.5 28.6 na 5.0 Ui -2.0 32.46 na MTR -2.0 35.49 na SRC -2.0 42.44 na The maximum velocity is 10.32 and it occurs in the pipe between nodes MTR and SRC Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams - 2007 VANGUARD FIRE PROTECTION INC Page 5 HAGUE RESIDENCE Date 11/12/2023 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 10.00 1.101 R 1.0 9.750 7.300 Qa = 10 to 150.0 0.0 1.000 0.0 2 10.0 0.0189 0.0 10.750 0.203 Vel= 3.37 2 10.00 1.101 0 5.0 0.660 7.503 Qa = 10 to 150.0 0.0 5.000 0.0 Al 20.0 0.0680 0.0 5.660 0.385 Vel = 6.74 0.0 20.00 7.888 K Factor = 7.12 3 0.0 1.101 0 5.0 5.750 8.597 to 150.0 0.0 5.000 0.0 A2 0.0 0.0 0.0 10.750 0.0 Vel = 0 0.0 0.0 8.597 K Factor = 0 ** Al 20.00 1.101 2R 2.0 8.420 7.888 to 150.0 0.0 2.000 0.0 A2 20.0 0.0680 0.0 10.420 0.709 Vel = 6.74 A2 0.0 1.101 3R 3.0 17.420 8.597 to 150.0 0 5.0 8.000 0.0 A3 20.0 0.0681 0.0 25.420 1.730 Vel = 6.74 A3 0.0 1.101 N 7.0 1.160 10.327 to 150.0 0.0 7.000 0.0 A4 20.0 0.0680 0.0 8.160 0.555 Vel = 6.74 A4 0.0 1.101 0 5.0 10.500 10.882 to 150.0 0.0 5.000 4.548 B4 20.0 0.0680 0.0 15.500 1.054 Vel = 6.74 84 0.0 1.101 20 10.0 29.870 16.484 to 150.0 R 1.0 11.000 0.0 B5 20.0 0.0680 0.0 40.870 2.781 Vel = 6.74 B5 0.0 1.101 R 1.0 13.500 19.265 to 150.0 N 7.0 8.000 0.0 TR 20.0 0.0680 0.0 21.500 1.463 Vel = 6.74 TR 0.0 1.101 Fsp 0.0 8.420 20.728 to 150.0 S 9.563 9.562 6.647 * Fixed Loss = 3 BR 20.0 0.0680 0.0 17.982 1.223 Vel = 6.74 BR 5.00 1.025 3E 8.1 5.000 28.598 Qa = 5 to 150.0 0.0 8.100 1.949 UI 25.0 0.1456 0.0 13.100 1.908 Vel = 9.72 UI 0.0 1.36 3E 12.666 70.000 32.455 to 150.0 0.0 12.667 0.0 MTR 25.0 0.0367 0.0 82.667 3.038 Vel = 5.52 MTR 0.0 0.995 Ball 2.628 15.000 35.493 to 150.0 T 5.841 8.469 3.000 * Fixed Loss = 3 SRC 25.0 0.1683 0.0 23.469 3.950 Vel = 10.32 0.0 25.00 42.443 K Factor = 3.84 Computer Programs by Hydratec Inc. Revision: 50.52.1 - Senju Sprinkler Model RC-RES K-Factor: 3.7 o SIN: SS8261 Residential Lead Free Flat Concealed Sprinkler, Pendent C®US LISTED IN5F/ANWCAN61&12I GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 131); wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 1313; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 3.7 (53.3 LPM/barh12) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The installation and maintenance of Model RC-RES must strictly adhere to the guidelines specified in this document, as well as comply with the standards and regulations set forth by the National Fire Protection Association (NFPA) and any other applicable Authorities Having Jurisdiction. Additionally, it is crucial that the final approval for installation is obtained from Authorities Having Jurisdiction. Failure to comply with these requirements may result in a compromise to the integrity and functionality of the devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. TECHNICAL DATA Approvals: cULus Listed NSF/ANSI/CAN 61, NSF/ANSVCAN 372 Sprinkler Identification Number (SIN): SS8261 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K = 3.7 GPM/psi112 (53.3 LPM/bar1 Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (720C): Uncolored 205°F (960C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (720C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes: White, Ivory, Beige, Brown, Black, Nickel, Copper, Wood Grain Custom Finishes: Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1.1 112°NPT 2-1/16° (052 mm) Lot No. I Year of Manufacture I— SIN: SS8261 3 I- K-Factor: K3.7 1 F 1— Temperature Rating: 4 I 162°F (7'2°C) or I 205°F (96°C) UL Mark 2 1— Control No.: 6P37 6 I- ALS Mark: NSF 611372 L_RESSPKR )) Body (Copper Alloy) ') Deflector (Phosphor Bronze) 2-518' (068 mm) @ Gasket (PIFE) or 3.1/4' (083 mm) @ Fusible Metal (Solder) or 2-518° square (068 mm) t: Heat Collector (Copper) :; Cover Plate Assembly Figure 1: Model RC-RES K =3.7 Color Code Marking (Deflector) 1A ,'•••- SIN: S58261 K-Factor 1(3.7 :• - / - Temperature Rating: . I •.- - I I -- •' '. UL Mark , N. Cover Plate Sprinkler (lop View) (Bottom View) Figure 1.1: Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge Figure 2: Operation Process (For illustrative purposes only) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Notes Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no bhnd spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13D, 13R, or 13) must be kept as few as possible while observing all guidelines relating to obstructions and spacing. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 130 and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 130, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1 GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. Table A. NFPA ThD & 13R Wet Pipe Hydraulic Design Criteria for Model 5S8261 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Maximum Ordinary Temperature IntennediateTemperature Coverage Spacing Rating 1627 (nC) Rating 205F (96C) Deflector to Installation Minimum Area(g) Ft xFt Ft. Ceiling Type Spacing Ft. (m) Flow°" GPM Pressure FIowmGPM Pressure (mx m) (m) (LPM) PSI (bar) (1PM) PSI (bar) 12x12 12 10 7.3 10 73 Smooth (3.7 x 3.7) (3.7) (37.9) (0.50) (37.9) (0.50) Ceilings 3/8 to 7/8 Inches. Beamed 14x14 14 10 7.3 10 7.3 (4.3 x 4.3) (4.3) (37.9) (0.50) (37.9) (0.50) Ceilings per _ NFPA 130, 13R or 13. Concealed (2.4) 8 15 x 15 15 12 10.5 12 10.5 (4.6 x 4.6) (4.6) (45.4) (0.72) (45.4) (072) Installed in beam 3/8 to 7/8 inches below bottom 1 16x16 16 13 12.3 13 12.3 (4.9 X 4.9) (4.9) (49.2) (0.85) (49.2) (0.85) of beam For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft1bs (9.5 to 19.0 Nm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Removal Tool for RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installation Steps Step 1: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2: With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3: If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Groove on the Spn Protective Cap Tooth on the Socket Socket NR-H Ratch I Correct I llncorrectl Figure 3: Installation Figure 4: Ratchet & Socket Step 4: Use the Cap Removal Tool for RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Sprinkler Head Protective Cap 1,1 Cap Removal Tool -- -3 I Pull down Step 1 Step 2 Step 3 Figure 5: Protective Cap Removal N Mounting \Surface Cover Plate Assembly L... -8amJ_ I or 3-1/4° (083 mm) or 2-518° square (068 mm) Figure 6: Installation (Cover Plate Assembly) Incorrect] I Correct I Incorrect I Figure 7: Installation (Correct and Incorrect) CARE & MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. Notes Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a-heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non- factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. LIMITED WARRANTY For details of warranty, refer to Sales Contract. ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES SIN: SS8261, Residential Flat Concealed Sprinkler, Pendent, K3.7, Temperature: 162°F (72°C) or 205°F (96°C) Cover Plate Assembly 2-5/8 inch (4)68mm) or 3-1/4 inch ((p83mm) or 2-5/8 inch square (068mm), Order separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. White Ivory I Beige 1Standard I Brown I Black I Nickel IFinishes Custom I Copper I Wood Custom Color Custom Grain I Pattern 2-5/8° Round, 140°F 0 3-1/4° Round, 140°F 0 0 0 0 0 0 0 0 0 0 2-5/80 Square, 140°F 0 - - - - - 2-5/8° Round, 162°F 3-1/4" Round, 162°F 2-5/8° Square, 162°F Tools & Accessories Socket NR-H for use with a 3/8° drive ratchet (not included) Socket NA-H Plastic for use with a 1/20 drive ratchet (not included) Cap Removal Tool for RC Cover Plate Installation Tool