Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4588 ADAMS ST; ; FPR2023-0024; Permit
city of Carlsbad Print Date: 05/01/2025 Job Address: 4588 ADAMS ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2061923800 Track #: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2023-0024 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 03/14/2023 Issued: 04/05/2024 DEV2017-0098 Finaled Close Out: 04/05/2024 Final Inspection: INSPECTOR: Cheung, Nathaniel Project Title: ADAMS RESIDENCE Description: CHAMBERS RESIDENCE -NEW 13D SPRINKLER SYSTEM FOR NEW SFR Applicant: JOSE BARAJAS FIRE PROTECTION JOSE BARAJAS 2159 GREEN BRIAR DR FALLBROOK, CA 92028-4387 (760) 419-1269 FEE - AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $148.00 FIRE NFPA 13D Single Family System (Plan Review) $292.00 Total Fees: $440.00 Total Payments To Date: $440.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: ADAMS STREET RESIDENCE Contract No. : 0013 City: CARLSBAD, CA 92008 Project Location: 4588 ADAMS STREET Date: 3/7/2023 Contractor Information -- Name of Contractor: JB FIRE PROTECTION Address: P0 BOX 1711 City: FALLBROOK, CA 92028 Phone Number: (760) 419-1269 E-mail: JBFIREPROTECTION@GMAIL.COM Name of Designer: JB FP Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 1 Remote Area Location MASTER BATH Occupancy Classification NFPA 13D Density (gpm/ft2) 0.05 Area of Application (ft2) 400 Coverage per Sprinkler (ft2) 400 Number of Calculated Sprinklers 1 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 25 Required Pressure at Source (psi) 71.3 Type of System Wet Volume - Entire System (gal) 58.5 gal Water Supply Information Date 3/6/2023 Location ADAMS STREET Source 1 Notes File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water © 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 81 500 76 Static Pressure Residual I I I Flow I Available I I I Total Demand Required Pressure Node at Source (psi) I Pressure I I I (gpm) I Pressure I I I (gpm) I (psi) (psi) i (psi) 1 81 76 500 81 25 71.3 Hoses Inside Hose Flow / Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 20 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 20 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 42 BOR -Flow (gpm) 20 Demand w/o System Pump(s) N/A File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: I Supply v System Demand 0 AvailableAt Source 150- 140- 130 120 110 100 81 @25 Psi 94 73 (I) 70 COD 0. 60 50 — 40 20 10•— 0• 0 200 300 400 500 600 Flow, gpm File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright ©2002-2012 Tyco Fire Protection Products Page 3 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 - Static 0 81 S2 Supply point #2 - Residual 500 76 Dl Elevation Pressure 0 24.5 D2 ISystem Demand 25 71.3 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I Pressure (psi) I Flow (gpm) I Pressure (psi) I © Flow (gpm) Supply 81 27.7 9.7 1 25 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi'/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead Sprinkler 400 4.9 0.05 20 16.7 0.05 20 16.7 File: E:\jobs\jobs\13—ADAMS STREET\1 3_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 4 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 101 29.5 4.9 20 1 2x(BM.Tee-Run)=2 8.31 150 16.7 061 30 20 1.101 2x(BM.90)=10 12 0.0679 -0.2 20.31 1.4 061 30 -8.5 1 4x(BM.Tee-Run)=4 20.13 150 17.9 068 30 11.5 1.101 4 0.0244 0 24.13 0.6 068 30 -2.4 1 3x(BM.Tee-Br)=15 15.05 150 18.5 041 20 9.1 1.101 2x(BM.90)=10 25 0.0157 4.3 40.05 0.6 041 20 -1.7 1 5x(BM.Tee-Run)=5 36.23 150 23.4 031 20 7.4 1.101 lx(BM.Tee-Br)=5 10 0.0107 0 46.23 0.5 031 20 12.7 1 llx(BM.90)=55 65.78 150 23.9 R-O 4.5 20 1.101 4x(BM.Tee-Run)=4 69 0.0679 6.7 2x(BM.Tee-Br)=10 134.78 9.2 R-O 4.5 0 1 0.5 39.8 CPVC CHECK R-I 4 20 0 0 2 0.2 *** 0.5 1 R-I 4 0 1 2 150 41 BOR 2 20 1.101 0 0.0679 0.9 2 0.1 BOR 2 0 1 lx(us.Tee-Br)=6.75 1 150 42 3B 1 20 1.025 6.75 0.0962 0.4 7.75 0.7 3B 1 5 1 2x(us.90)=5.4 4 150 43.2 3A -1 25 1.025 5.4 0.1454 0.9 9.4 1.4 3A -1 0 2 4x(BM.45)=8 245.32 150 45.4 2A -27 25 2.003 lx(BM.90)=10 18 0.0056 11.3 263.32 1.5 2A -27 0 1 0.5 150 58.1 BF-0 -27 25 1.025 0 0.1454 0 0.5 0.1 BF-0 -27 0 1 0.5 58.2 950XL BF-I -27 25 0 0 11.2926 0 *** 0.5 5.6 BF-I -27 0 1 0.5 150 63.9 2-0 -27 25 1.025 0 0.1454 0 0.5 0.1 2-0 -27 0 1 0.5 63.9 WATER METER 2-1 -27 25 0 0 6.0002 0 0.5 3 2-I -27 0 1 lx(us.Tee-Br)=5.84 20 150 66.9 1A -27 25 0.995 5.84 0.168 0 25.84 4.3 1A -27 0 10 1 150 71.3 1 -27 25 9.8 0 0 0 1 0 1 71.3 File: E:\jobs\jobs\13-ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) Wpm) (in) (ft) (ft) (psi) (psi) Path No: 2 G5 1 5 1 0.5 150 43.2 3B 1 5 1.025 0 0.0074 0 0.5 0 3B 43.2 Path No: 3 061 30 0 1 2x(BM.Tee-Run)=2 30.59 150 17.9 057 30 8.5 1.101 2x(BM.Tee-Br)=10 17 0.0139 0 lx(BM.90)=5 47.59 0.7 057 30 2.4 1 lx(BM.Tee-Br)=5 11.62 150 18.5 052 20 10.9 1.101 2x(BM.90)=10 15 0.0222 4.3 26.62 0.6 052 20 1.7 1 1x(BM.Tee-Run)=1 9.73 150 23.4 031 20 12.7 1.101 lx(BM.Tee-Br)=5 6 0.0291 0 15.73 0.5 031 23.9 Path No: 4 068 30 0 1 4x(BM.Tee-Run)=4 35.27 150 18.5 057 30 2.4 1.101 lx(BM.Tee-Br)=5 19 0.0014 0 2x(BM.90)=10 54.27 0.1 057 18.5 Path No: 5 041 20 0 1 4x(BM.Tee-Run)=4 35.29 150 23.4 052 20 1.7 1.101 2x(BM.Tee-Br)=10 14 0.0007 0 49.29 0.0 052 23.4 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 10.33 ft/s occurs in the following pipe(s): (1A-2-I) '"" Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: E:\jobs\jobs\1 3-ADAMS STREE13ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: ADAMS STREET RESIDENCE DeviceGraphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 15 - 10 - 55 - 50 - 55 - 50 - 55 - $O - 55 30 - 25 20 - 15 - 101 - 5 — N en Flow, gpm Pressure Loss Function Design Area: 1; BFP Ref.: 168 (950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 5.6 psi @25 gpm N N Flow, gpm File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 Job: ADAMS STREET RESIDENCE Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 167 (WATER METER, Size = 1); Inlet Node: 2-I; Outlet Node: 2-0 3psi25gpmfl 2.9 - U) 2.4 - I- U) U) - 1.9- CL 1.4 - 0.9 0.4 - 00 0 v N '0 00 0 oi '0 00 N N Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 169 (CPVC CHECK, Size = 1); Inlet Node: R-l; Outlet Node: R-O 1psi@2Ogpm 0 0 0 0 0 — N N Flow, gpm File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 HYDRAULIC CALCULATIONS for Job Information Project Name: ADAMS STREET RESIDENCE Contract No. 0013 City: CARLSBAD, CA 92008 Project Location: 4588 ADAMS STREET Date: 3/7/2023 Contractor Information Name of Contractor: JB FIRE PROTECTION Address: P0 BOX 1711 City: FALLBROOK, CA 92028 Phone Number: (760) 419-1269 E-mail: JBFIREPROTECTION@GMAIL.COM Name of Designer: JB FP Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 2 Remote Area Location KITCHEN Occupancy Classification NFPA 13D Density (gpm/ft2) 0.051 Area of Application (ft2) 512 Coverage per Sprinkler (ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 31.2 Required Pressure at Source (psi) 75.5 Type of System Wet Volume - Entire System (gal) 60.1 gal Water Supply Information Date 3/6/2023 Location ADAMS STREET Source 1 Notes File: E:\jobs\jobs\113—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 41 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 2 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 81 500 76 Static Pressure Residual Flow I Available I I Total Demand Required Pressure Node at Source (psi) Pressure I I (gpm) Pressure I (gpm) i (psi) (psi) (psi) I 1 81 76 500 81 31.2 75.5 Hoses Inside Hose Flow I Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 26.2 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 26.2 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 40.5 BOR -Flow (gpm) 26.2 Demand w/o System Pump(s) NIA File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 2 File: E:\jobsobs\13_ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 3 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 - Static 0 81 S2 Supply point #2 - Residual 500 76 Dl Elevation Pressure 0 22.3 D2 System Demand 31.2 75.5 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I Pressure (psi) I Flow (gpm) I Pressure (psi) I @ Flow (gpm) Supply 81 32.9 5.5 31.2 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.051 13 7 202 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.052 13.3 7.3 File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 4 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 201 24.5 4.9 13 1 lx(BM.Tee-Run)=1 14.16 150 7 081 25 13 1.101 2x(BM.90)=10 11 0.0304 70.2 25.16 0.8 081 25 13.3 1 2x(BM.Tee-Run)=2 22.22 150 7.5 073 30 26.2 1.101 lx(BM.Tee-Br)=5 17 0.1119 -2.2 2x(BM.90)=I0 39.22 4.4 073 30 -8.3 1 2x(BM.Tee-Run)=2 5.75 150 9.8 057 30 17.9 1.101 2 0.0551 0 7.75 0.4 057 30 -3.5 1 2x(BM.Tee-Br)=10 11.62 150 10.2 052 20 14.3 1.101 2x(BM.90)=10 20 0.0366 4.3 31.62 1.2 052 20 2.2 1 lx(BM.Tee-Run)=1 9.73 150 15.7 031 20 16.6 1.101 lx(BM.Tee-Br)=5 6 0.0479 0 15.73 0.8 031 20 9.6 1 llx(BM.90)=55 65.78 150 16.4 R-O 4.5 26.2 1.101 4x(BM.Tee-Run)=4 69 0.1119 6.7 2x(BM.Tee-Br)=10 134.78 15.1 R-O 4.5 0 1 0.5 38.2 CPVC CHECK R-I 4 26.2 0 0 2 0.2 *** 0.5 1 R-I 4 0 1 2 150 39.5 BOR 2 26.2 1.101 0 0.1119 0.9 2 0.2 BOR 2 0 1 lx(us.Tee-Br)=6.75 1 150 40.5 3B 1 26.2 1.025 6.75 0.1585 0.4 7.75 1.2 3B 1 5 1 2x(us.90)=5.4 4 150 42.2 3A -1 31.2 1.025 5.4 0.219 0.9 9.4 2.1 3A -1 0 2 4x(BM.45)=8 245.32 150 45.1 2A -27 31.2 2.003 lx(BM.90)=10 18 0.0084 11.3 263.32 2.2 2A -27 0 1 0.5 150 58.6 BF-0 -27 31.2 1.025 0 0.219 0 0.5 0.1 BF- O -27 0 1 0.5 58.7 950XL BF-I -27 31.2 0 0 12.2205 0 0.5 6.1 BF-I -27 0 1 0.5 150 64.8 2-0 -27 31.2 1.025 0 0.219 0 0.5 0.1 2-0 -27 0 1 0.5 64.9 WATER METER 2-1 -27 31.2 0 0 8.0006 0 0.5 4 2-I -27 0 1 lx(us.Tee-Br)=5.84 20 150 68.9 1A -27 31.2 0.995 5.84 0.2531 0 25.84 6.5 File: E:\jobs\jobs\13_ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/psi'/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 1A -27 0 10 1 150 75.5 1 -27 31.2 9.8 0 0 0 1 0 1 75.5 Path No: 2 202 24.5 4.9! 13.3 1 1x(BM.Tee-Br)=5 4.16 150 7.3 081 25 13.3 1.101 lx(BM.90)=5 10 0.0316 -0.2 14.16 0.4 081 7.5 Path No: 3 G5 1 5 1 0.5 1501 42.2 3B 1 5 1.025 0 0.0074 0 0.5 0 3B 42.2 Path No: 4 073 30 0 1 1x(BM.Tee-Br)=5 29.52 150 9.8 068 30 8.3 1.101 2x(BM.Tee-Run)=2 17 0.0134 0 2x(BM.90)=10 46.52 0.6 068 30 3.5 1 2x(BM.Tee-Br)=10 15.05 150 10.4 041 20 11.9 1.101 2x(BM.90)=10 20 0.0258 4.3 35.05 0.9 041 20 -2.2 1 5x(BM.Tee-Run)=5 36.23 150 15.6 031 20 9.6 1.101 1x(BM.Tee-Br)=5 10 0.0175 0 46.23 0.8 031 16.4 Path No: 5 057 30 0 1 5x(BM.Tee-Run)=5 50.72 150 10.2 068 30 3.5 1.101 2x(BM.Tee-Br)=10 20 0.0028 0 lx(BM.90)=5 70.72 0.2 068 10.4 Path No: 6 041 f 20 0 1 4x(BM.Tee-Run)=4 35.29 150 15.6 052 I 20 2.2 1.101 2x(BM.Tee-Br)=10 14 0.0012 0 49.29 0.1 052 15.7 File: E:\jobs\jobs\13-ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 12.88 ft/s occurs in the following pipe(s): (1A-2-I) "p" Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job: ADAMS STREET RESIDENCE Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: 1; Supply Name:1 15-i- 00 ('1 Flow, gpm Pressure Loss Function Design Area: 2; BFP Ref.: 168 (950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 6.1 psi© 31 .2 g pm 2 0 Flow, gpm File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 Job ADAMS STREET RESIDENCE Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 167 (WATER METER, Size = 1); Inlet Node: 2-I; Outlet Node: 2-0 4 psi @31.2 gpmj I I II 00 en 00 ' 00 0 - N N N N en en en en N en Flow, gpm Pressure Loss Function Design Area: 2; Valve Ref.: 169 (CPVC CHECK, Size = 1); Inlet Node: R-I; Outlet Node: R-0 @26.2gpm psi 0.6 0.1- - 0 0 0 0 0 0 Flow, gpm File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 copyright © 2002-2012 Tyco Fire Protection Products Page 9 HYDRAULIC CALCULATIONS for Job Information Project Name: ADAMS STREET RESIDENCE Contract No. 0013 City: CARLSBAD, CA 92008 Project Location: 4588 ADAMS STREET Date: 3/7/2023 Contractor Information - Name of Contractor: JB FIRE PROTECTION Address: P0 BOX 1711 City: FALLBROOK, CA 92028 Phone Number: (760)419-1269 E-mail: JBFIREPROTECTION@GMAIL.COM Name of Designer: JB FP Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 3 Remote Area Location MASTER BEDROOM Occupancy Classification NFPA 13D Density (gpmlft2) 0.051 Area of Application (ft2) 512 Coverage per Sprinkler (ft') 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 31.1 Required Pressure at Source (psi) 72.9 Type of System Wet Volume - Entire System (gal) 58.4 gal Water Supply Information Date' 3/6/2023 Location ADAMS STREET Source 1 Notes File: E:\jobs\jobs\1 3ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 1 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 3 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lbs/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water © 60F (1.5.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 81 500 76 Static Pressure I Residual I Flow I Available I Total Demand I Required Pressure Node atSource (psi) Pressure (gpm) Pressure (gpm) I (psi) (psi) I (psi) I 81 76 500 81 31.1 72.9 Hoses Inside Hose Flow / Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers - Ovehead Sprinkler Flow (gpm) 26.1 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 26.1 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 38.1 BOR -Flow (gpm) 26.1 Demand w/o System Pump(s) N/A File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 3 U Supply D System Demand 0 Available At Source 150- - 140- 130- 120- 110- 1001 81 psi @31.1gpm CL 73 0 7T4-~- 50 Dl 0 200 300 400 500 600 Flow, gpm File: E:\jobs\jobs\1 3 ADAMS STREET\13 ADAMS STREET.dwg Date 3/7/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job: ADAMS STREET RESIDENCE Hydraulic Analysis for: 3 Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 - Static 0 81 S2 Supply point #2 - Residual 500 76 Dl Elevation Pressure 1 0 24.5 D2 I System Demand 31.1 72.9 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin Pressure (psi) I Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 81 33.8 8.1 1 31.1 Open Heads Required ____________ Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 301 Overhead 256 4.9 0.05 12.8 7 0.051 13 7 Sprinkler 302 Overhead 256 4.9 0.05 12.8 7 0.051 13.1 7.2 Sprinkler File: E:\jobs\jobs\i 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 4 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 301 29.5 4.9 13 1 lx(BM.Tee-Br)=5 3.38 150 7 060 30 13 1.101 lx(BM.90)=5 10 0.0304 -0.2 13.38 0.4 060 30 -0.8 1 lx(BM.Tee-Run)=1 21.94 150 7.2 057 30 12.2 1.101 lx(BM.Tee-Br)=5 11 0.0272 0 lx(BM.90)=5 32.94 0.9 057 30 2.2 1 lx(BM.Tee-Br)=5 11.62 150 8.1 052 20 14.4 1.101 2x(BM.90)=10 15 0.037 4.3 26.62 1 052 20 2.1 1 lx(BM.Tee-Run)=1 9.73 150 13.4 031 20 16.5 1.101 lx(BM.Tee-Br)=5 6 0.0475 0 15.73 0.7 031 20 9.6 1 llx(BM.90)=55 65.78 150 14.2 R-O 4.5 26.1 1.101 4x(BM.Tee-Run)=4 69 0.1107 6.7 2x(BM.Tee-Br)=10 134.78 14.9 R-O 4.5 0 1 0.5 35.8 CPVC CHECK R-I 4 26.1 0 0 2 0.2 *** 0.5 1 R-I 4 0 1 2 150 37 BOR 2 26.1 1.101 0 0.1107 0.9 21 0.2 BOR 2 0 1 lx(us.Tee-Br)=6.75 1 150 38.1 3B 1 26.1 1.025 6.75 0.1569 0.4 7.75 1.2 3B 1 5 1 2x(us.90)=5.4 4 150 39.7 3A -1 31.1 1.025 5.4 0.2171 0.9 9.4 2 3A -1 0 2 4x(BM.45)=8 245.32 150 42.7 2A -27 31.1 2.003 lx(BM.90)=10 18 0.0083 11.3 263.32 2.2 2A -27 0 1 0.5 150 56.1 BF-0 -27 31.1 1.025 0 0.2171 0 0.5 0.1 BF-0 -27 0 1 0.5 56.2 950XL BF-1 -27 31.1 0 0 12.1932 0 0.5 6.1 BF-I -27 0 1 0.5 150 62.3 2-0 -27 31.1 1.025 0 0.2171 0 0.5 0.1 2-0 -27 0 1 0.5 62.4 WATER METER 2-1 -27 31.1 0 0 8.0062 0 0.5 4 2-I -27 0 1 lx(us.Tee-Br)=5.84 20 150 66.4 1A -27 31.1 0.995 5.84 0.2509 0 25.84 6.5 1A -27 0 10 1 150 72.9 1 -27 31.1 9.8 0 0 0 1 0 1 72.9 File: E:\jobs\jobs\1 3-ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 Job ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 302 29.5 4.9 13.1 1 1x(BM.Tee-Run)=1 2.17 150 7.2 061 30 13.1 1.101 lx(BM.Tee-Br)=5 6 0.031 -0.2 8.17 0.3 061 30 0.8 1 4x(BM.Tee-Run)=4 20.13 150 7.2 068 30 13.9 1.101 4 0.0344 0 24.13 0.8 068 30 -2.2 1 3x(BM.Tee-Br)=15 15.05 150 8 041 20 11.6 1.101 2x(BM.90)=10 25 0.0249 4.3 40.05 1 041 20 -2.1 1 5x(BM.Tee-Run)=5 36.23 150 13.4 031 20 9.6 1.101 1x(BM.Tee-Br)=5 10 0.0173 0 _______ 46.23 0.8 031 14.2 Path No: 3 G5 1 5 1 0.5 150] 39.7 3B 1 5 1.025 0 0.00741 0 0.5 L 0 3B 39.7 Path No: 4 060 30 0 1 1x(BM.Tee-Br)=5 8.65 1501 7.2 061 30 0.8 1.101 5 0.0002 0 13.65 0 061 7.2 Path No: 5 068 30 0 1 4x(BM.Tee-Run)=4 35.27 150 8 057 30 2.2 1.101 lx(BM.Tee-Br)=5 19 0.0012 0 2x(BM.90)=10 54.27 0.1 057 8.1 Path No: 6 041 20 0 1 4x(BM.Tee-Run)=4 35.29 150 13.4 052 20 2.1 1.101 2x(BM.Tee-Br)=10 14 0.001 0 49.29 0.1 052 13.4 File: E:\jobs\jobs\13-ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: ADAMS STREET RESIDENCE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi½) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 12.82 ft/s occurs in the following pipe(s): (1A-2-I) " Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: E:\jobs\jobs\13—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 Job: ADAMS STREET RESIDENCE Device Graphs Pressure vs. Flow Function Design Area: 3; Supply Ref.: 1; Supply Name:1 45 - 40 - 35 - 30 - 15 10 Flow, gpm Pressure Loss Function Design Area: 3; BFP Ref.: 168 (950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 6.1 PSI @ 31.1 gpm 7. - _______ - - 2 0 2 Flow, gpm File: E:\jobs\jobs\1 3—ADAMS STREET\13_ADAMS STREET.dwg Date 3/7/2023 Copyright © 2002-2012 Tyco Fire Protection Products 0 '0 Page 8 Job: ADAMS STREET RESIDENCE Device Graphs Pressure Loss Function Design Area: 3; Valve Ref.: 167 (WATER METER, Size = 1); Inlet Node: 2-I; Outlet Node: 2-0 4psi @31.1 gpm I I I II Q. 2.4 I- C', 1.9- 0. 1 .4- 0.9• 0.4 00 0 en en O 00 e n e \O 00 0 — N N N N en en en en N en Flow, gpm Pressure Loss Function Design Area: 3; Valve Ref.: 169 (CPVC CHECK, Size = 1); Inlet Node: R-l; Outlet Node: R-0 fipsi @26.1 g — 0.6- - 0.1• - 0 0 0 0 0 0 - N en en Flow, gpm File: E:\jobs\jobs\1 3—ADAMS STREE13_ADAMS STREET.dwg Date 3/7/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 9 Model 950XLT2 Top Access Double Check Valve Assembly Application Ideal for use where LeadFree* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. A test cock plug is provided to protect against fouling caused by insects, dirt and debris. Assembly shall provide protection where a potential non-health hazard exists. Standards Compliance (Unless otherwise noted, applies to 3/4" thru 2" Horizontal) ASSE® Listed 1015 (Vertical flow-up:1 1/4" thru 2") IAPMO® Listed CSA® Certified (Vertical flow-up:1 1/2" & 2") AWWA Compliant C510 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI/CAN 61 *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Low Lead Cast Bronze ASTM B 584 Access covers Low Lead Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone Buna Nitrile Polymers NorylTM Springs Stainless steel, 300 series Test cock cover Plastic Ball valve handles Stainless steel ' \ 49,7 I IN ~ No 9 C LEAD FREE NSF/ANSI/CAN 61 Features Sizes: 3/4", 1", 1 1/4", 1 1/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131 .20.1 Options (Suffixes can be combined) O FT - with "Fast Test" test cocks 0 5 - with Model SXL lead-free bronze "Y" type strainer Accessories O Repair kit (rubber only) 0 Thermal expansion tank (Model XT) o QT-SET Quick Test Fitting Set OPTIONAL LEAD-FREE STRAINER (MODEL SXL) oI'ID A Dimensions & Weights (do not include pkg.) DIMENSIONS (approximate) MODEL SIZE in. mm A in. mm B in. mm C in. mm D in. I mm E in. mm F in. mm G in. mm WITH BALL VALVES lbs. I kg 3/4 20 13 330 83/4 222 23/8 60 25/16 59 35/16 84 3/4 19 175/8 448 6 2.7 1 25 14 356 83/4 222 21/2 64 25/16 59 35/16 84 3/4 19 193/4 502 12 5.4 11/4 32 195/8 499 133/4 349 4 102 35/8 92 43/8 111 1 5/16 33 243/4 629 22 10 11/2 40 205/16 516 133/4 349 53/8 137 35/8 92 43/8 111 1 5/16 33 2515/16 659 22 10 2 50 213/8 543 13 3/4 349 513/16 148 35/8 92 43/8 111 15/16 33 28 5/16 719 29 13.2 Zurn Industries, LLC I Wilkins Rev. J 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 8/20 In Canada I Zurn Industries Limited Document No. BF-950XLT2 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 Product No. Model 950XL12 www.zurn.com Patent zurn.com/patents Pagel of 2 103 U) 69 U) —J uJ DIRECTION OF FLOW Flow Characteristics 0 Rated Flow (established by approval agencies) MODEL 950XLT2 314", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (lis) 2.52 3.8 5.0 15 3.2 6.3 9.5 I 1 I 10 5 0 1.26 NFEAN I '1i 11 12.6 15.8 I DI PIMP— I j1 III' 1.1' 'un FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Un- less otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. If installed below grade, be certain adequate drainage is provided to prevent the device from being submerged. Capacity thruSchedule 40 Pipe Pipe size 5 Wsec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8' 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4° 23 35 47 70 1 1/2' 32 48 63 95 52 78 105 167 OPTIONAL LEAD-FREE STRAINER (MODEL SXL) PROTECTIVE ,/ENCLOSURE (PROVIDED BY OTHERS) T 0 DIRECTION OF FLOW OUTDOOR INSTALLATION PIT INSTALLATION Specifications The Double Check Type Backf low Preventer shall be certified to NSF/ANSI/CAN 61, shall be ASSE Listed 1015, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be NorylTM and the seat disc elastomers shall be SILICONE. The first and second check shall be located at a 45° angle and accessible for maintenance from the top of the device, without removing the device from the line. Each check shall have separate access covers and test cocks shall be accessible from the top of the device. Test cocks shall be protected from debris by a plug. The Double Check Type Backflow Preventer shall be a ZURN WILKINS Model 950XLT2. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 tqcce Worldwide I Contacts I www.tyco-fire.com BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFPI9I5 TFPI9I5 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 @2018 Johnson Controls. All rights reserved. All specifications and other Information shown were current as of document revision dots and are subject to change without notice. Johnson "1 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA ore regiurervd trcdunrurku of National Fire Protection Association; BLAZEMASTER is ctrcdenrurk of The Lobricol Corporation Controls tqcae Worldwide www.tyco-fire.com Contacts Series LFII Residential Sprinklers 49 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/series-lfii- res-4_9-k-domed-pen-wet-dry General Description The TYCO Series LFll Residential Domed-Plate Concealed Pendent 4.9 K-factor Sprinklers (TY2234) are dec- orative, fast response, frangible bulb sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. The Cover Plate/Retainer Assembly conceals the sprinkler operating com- ponents above the ceiling. The domed profile of the cover plate provides aes- thetically appealing sprinkler design with lower flow rates than can be achieved by lower profile cover plates. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprinklers and pressure testing of the fire protec- tion system prior to the installation of the ceiling or application of a finish coating. Also, the separable "push-on and thread-off" two-piece design of the Sprinkler provides for 1/2 in. (12,7 mm of vertical adjustment. The Series LFII Residential Sprinklers (TY2234) are intended for use in the fol- lowing scenarios: wet and dry pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFll Residential Sprin- klers have been designed with heat sensitivity and water distribu- tion characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFll Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) are shipped with a Dispos- able Protective Cap. The Protective Cap is temporarily removed for instal- lation, and it must be replaced to protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Protective Cap. When ceiling installa- tion is complete, the Protective Cap must be removed and the Cover Plate Assembly installed. The Protective Cap must be removed to ensure proper performance of the sprinklers. Dry Pipe System Application The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) Listing offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Domed- Plate Concealed Pendent Sprin- klers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is customary for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFll Resi- dential Domed-Plate Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. IiLI)lIW The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the NATIONAL FIRE PRO- TECTION ASSOCIATION, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Page 1 of 6 MARCH 2022 TFP450 TFP45O Page 2 of 6 SEALING / FRAME ASSEMBLY (1/2" NPT) / WRENCH / BUTTON FLATS It SUPPORT I - CUP WITH SPRINKLER I I 0 ROLL FORMED STRAP (SEE II THREADS INSTALLATION I SECTION) BULB DEFLECTOR COMPRESSION SPRINKLER/SUPPORT CUP SCREW ASSEMBLY THREAD INTO 0 RETAINER SUPPORT CUP 0 WITH THREAD UNTIL MOUNTING TABS SURFACE IS FLUSH WITH EJECTION CElLlNG\ SPRING SOLDER COVER TABS (3) PLATE COVER PLATE/RETAINER ASSEMBLY FIGURE 1 SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TY2234) (Shown with Sprinkler Strap) Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NYC Approved under MEA 44-03-E The Series LFII Residential Domed- Plate Concealed Pendent Sprinklers are only listed with the Series LFII Residential Domed-Plate Concealed Pendent Cover Plates having a factory applied finish. For details on these approvals, refer to the Design Criteria section. All listed cover plates and correspond- ing part numbers having factory applied finishes can be found in the Ordering Procedure section of this data sheet. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 4.9 GPM/p5i½ (70,6 LPM/bar") Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 in. (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Frame .............................Brass Button ............................Bronze Sealing Assembly. Beryllium Nickel WI TEFLON Bulb (3 mm) .........................Glass Compression Screw ..................Brass Deflector .........................Copper Button Ejection Spring ........Stainless Steel Support Cup ........................Steel Cover Plate .........................Brass Retainer............................Brass Cover Plate Ejection Spring . . . . Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the Sprinkler Assem- bly. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to acti- vate and flow water. Design Criteria The TYCO Series LFII Residential Domed-Plate Concealed Pendent 4.9 K-factor Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturers recommendations that may be accept- able to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rate are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. TFP45O Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure b, C Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area' Ft 155°F (68°C) ___________ Minimum Ft x Ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type Ft GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings /4 in. to 3/4 in. 14x14 14 13 7.0 (4,3 X 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 (2,4) 16x16 (4,9x4,9) 16 (4,9) 13 (49,2) 7.0(0,48) 13R Installed in 18 x 18 18 17 12.0 (5,5 x 5,5) (5,5) (64,3) (0,83) Beam 1/4 in. to 3/4 in. below bottom of 20 x 20 20 20 16.7 (6,1 x 6,1) (6,1) (75,7) (1,15) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next high- est coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEMS SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure b,C Maximum Maximum Coverage Spacing Ordinary Temp Rating Minimum Area' Ft x Ft Ft 155°F (71°C) __________ __________ Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings /4 in. to 3/4 in. 14x14 14 14 8.2 (4,3 X 4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 130 or Concealed 8 (2,4) 16x16 (4,9 x 4,9) 16 (4,9) 15 (56,8) 9.4 (0,65) 13R Installed in 18 x 18 18 20 16.7 (5,5 x 5,5) (5,5) (75,7) (1,15) Beam 1/4 in. to 3/4 in. below bottom of 20 x 20 20 22 20.2 (6,1 x6,1) (6,1) (83,3) (1,39) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL DOMED-PLATE CONCEALED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP45O Page 4 of 6 2-1/2 DIA. SPRINKLER- (63,5 mm) 1/2 (12,7 mm) FACE OF SUPPORT CUP ASSEMBLY 1/2 / THREADED SPRINKLER COVER NPT ADJUSTMENT FITTING 3/32 GAP PLATE 1-3/16±1/4 RETAINER mm) - (30,2 mm ±6,4 mm) MOUNTING SURFACE COVER- SPRINKLER- 15/16 RETAINER SUPPORT CUP (23,8 mm) 1/4 (6,4 mm) OPERATED 3/4 (19,1 mm) SPRINKLER ASSEMBLY ASSEMBLY 3-5/16 DIA. PROTECTIVE (84,1 mm) TIP CAP FIGURE 2 DOMED CONCEALED COVER FOR USE WITH SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLERS (TY2234) (Shown with Protective Cap) Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area. A minimum discharge of 0.1 gpm/ft2. over the design area comprised of the four most hydraulically demand- ing sprinklers for the actual coverage areas being protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Pendent Sprinklers (TY2234) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. The Series LFll Residential Domed- Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Sprinkler Spacing The minimum spacing between sprinklers is 8 ft (2,4 m). The maxi- mum spacing between sprinklers cannot exceed the length of the cover- age area (Table A or B) being hydrauli- cally calculated (e.g., maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area). Installation The TYCO Series LFII Residential Domed-Plate Concealed Pendent 4.9 K-factor Sprinklers (TY2234) must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler in the pendent position and with the center- line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Refer to NFPA 13 for guidance regard- ing removal of protective straps and caps Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 7 Wrench shown in Figure 3, install and tighten the Sprinkler/Support Cup Assembly into the fitting. The W-Type 7 Wrench will accept a 1/2 in. ratchet drive. TFP45O Page 5 of 6 Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Pro- tective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. As long as the Sprinkler Strap (Figure 1) or the Protective Cap (Figure 2) remains in place, the system is considered to be "Out Of Service." Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Pro- tective Cap and the Sprinkler Strap. NOTE: Refer to Technical Data Sheet TFP700 regarding instructions for the removal of the Sprinkler Strap. Step 6. Push the Cover Plate/Retainer Assembly into the Support Cup, and as necessary, make the final adjust- ment of the Cover Plate with respect to the ceiling by turning the Cover Plate/ Retainer Assembly clockwise until its flange just comes in contact with the ceiling. If it becomes necessary to remove the Cover Plate, it can be removed by unscrewing in a counter-clockwise direction. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer Assembly cannot be engaged suffi- ciently to contact the ceiling, the Sprin- kler Fitting must be repositioned. Care and Maintenance The TYCO Series LFII Residential Domed-Plate Concealed Pendent 4.9 K-factor Sprinklers (TY2234) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of a Cover Plate may delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does not seal off any of the air gap. Failure to do so may impair sprin- kler operation. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (e.g., NFPA 25), in addi- tion to the standards of any authorities having jurisdiction. Contact the install- ing contractor or product manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (TY2234), K = 4.9, Residential Domed-Plate Concealed Pendent Sprinkler without Cover Plate Assembly, P/N 51-873-1-155 Cover Plate Assembly Specify: Series LFII (TY2234), K = 4.9, Residential Domed-Plate Concealed Pendent Sprinkler Cover Plate Assem- bly with (specify) finish, P/N (specify): Pure White* (RAL9010) .....PIN 56-873-3-135 Signal White (RAL9003).....P/N 56-873-4-135 Chrome..................P/N 56-873-9-135 Custom .................P/N 56-873-X-135 * Eastern Hemisphere sales only. Do not pull the Cover Plate relative to Sprinkler Wrench the Retainer. Separation may result. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or overheated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation section for additional information. TFP45O Page 6 of 6 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Otto © 2022 Johnson Controls. All rights reserved. All specifIcatIons and other information shown were current as of document revIsion date and ore subject to change Without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademark, of Notional Fire Protection Association; Controls TEFLON isatradenrurk of The Cheeroorc Company FC. LLC Worldwide I tqC170 Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2236) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2236) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet pipe residential sprinkler sys- tems for one- and two-family dwell- ings and mobile homes per NFPA 13D wet pipe residential sprinkler sys- tems for residential occupancies up to and including four stories in height per NFPA 13R wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings when used with one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by either Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable Approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2236) described herein must be installed and maintained in compli- ance with this document and the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. SEPTEMBER 2020 Sprinkler Identification Number (SIN) TY2236 TY2236 is a replacement for the TY2234. Technical Data Approvals UL and C-UL Listed Certified to all requirements of NSF/ANSI 61 Note: Sprinklers with a polyester finish are UL Listed as corrosion-resistant sprinklers. See the Design Criteria section for details on these approvals. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi"° (70,6 1pm/bar½) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White Polyester Coated, Signal White Polyester Coated, Jet Black Polyester Coated, or Chrome Plated TFP4O3 TFP4O3 Page 2 of 4 7/16 (11,1 mm) 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 1 - Frame 2 - Button MAKE-IN SURFACE 3 - Sealing Assembly 4 -Bulb 1 / 5 - Compression Screw 2 2-1/4" 6 - Deflector* , (57,2 mm) 4 1-5/8 (41,3 mm) * Temperature rating is indicated on 6* Deflector. CROSS SECTION PENDENT 2-7/8' DIA. (73,0 mm) WRENCH ~W) STYLE 15or20 FLATS RECESSED ESCUTCHEON RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2236) 2-7/8" DIA. 3/8±5/16" (73,0 mm) 5/8" (15,9 mm) (9,5±7,9 mm) 2-1/4" DIA. FLUSH - FACE OF (57,2 mm) SPRINKLER MOUNTING FITTING PLATE MOUNTING q, J 1/8" (3,2 mm) SURFACE /..1-9/16" (39,7 mm) CLOSURE TY2236 15/16" (23,8 mm) FIGURE 2 SERIES LFII RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON WRENCH RECESS (END "A" USED FOR TY2236) FIGURE 4 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. (73,0 mm) - 5/16±1/4" 1/2(12,7mm) (7,9±6,4 mm) 2-1/4" DIA. FLUSH FACE OF SPRINKLER 57 2 mm) MOUNTING FITTING PLATE MOUNTING / (3,2 mm) SURFACE / 1-9/16" (39,7 mm) CLOSURE TY2236 1-1/16" (27,0 mm) FIGURE 3 SERIES LFII RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP4O3 Page 3 of 4 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (1) 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing ft x ft Flow Pressure Flow Pressure Ceiling Type ft (m x m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 (3,7 x 3,7) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) Smooth Ceilings 1-1/4 in. to 4 in. Recessed us- 14 X 14 13 7.0 13 7.0 (4,3 X 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Ceilings per ing either Style 15 or Style 20 8Escutcheon 16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R 1-1/4 in. to or non-recessed per NFPA 13D, (2,4) 18 x 18 17 12.0 17 12.0 (5,5 X 5,5) (64,3) (0,83) (64,3) (0,83) 1-3/4 in. below bottom of beam. 13R, or 13 20x20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2236) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Physical Characteristics Frame .............................Brass Button ...........................Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb (3 mm)........................Glass Compression Screw .................Bronze Deflector ..........................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- ers recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing and the C-UL Listing, wet pipe systems may be utilized. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the design area comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1 1/4 in. to 4 in. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. TFP4O3 Page 4 of 4 Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, as shown in Figure 4. With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install the recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing either the Style 15 or the Style 20 Mounting Plate over the sprinkler threads, and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, as shown in Figure 5. With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed, or the finish coat has been applied, slide on either the Style 15 Closure or the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION, such as NFPA 25, in addi- tion to the standards of any authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII 4.9K Residential Pendent Sprinkler (TY2236), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .................51-212-1-155 Pure White (RAL 9010) Polyester', 2 51 -212-3-155 Signal White (RAL 9003) Polyester' ....................51 -212-4-155 Jet Black (RAL 9005) Polyester' ....................51 -212-5-155 Chrome Plated ................51-212-9-155 175-11'(79-10) Natural Brass ..................51-212-1-175 Pure White (RAL 9010) Polyester1.2 ..................51-212-3-175 Signal White (RAL 9003) Polyester1 ....................51 -212-4-175 Jet Black (RAL 9005) Polyester' ....................51 -212-5-175 Chrome Plated ................51 -212-9-175 UL Listed as corrosion-resistant. Eastern Hemisphere sales Only. Recessed Escutcheon Specify: Style 15 Escutcheon with (specify*) finish, P/N (specify*) or Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 e 2019 Johnson Controls. All rights reserved. All specifications and Other Information shown were current as of document revision date and are subject to change without notice. Johnson '1 VO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA am,egivle,od t,eden,neknol Nelivnvl Fine Protection Avco*ietion; TEFLON is a nogivienod t,ude,ne,k of DuPont Controls Worldwide I tqcuo Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/ series-ty-frb-5-6K General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. FTOTM The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.61K, 1/2 in. NPT TY323 .... Pendent 5.61K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi/2 (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze Page 1 of 4 NOVEMBER 2021 TFPI72 2-7/8 (73,0 mm) DIA. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN 7/16 (11,1 mm) NOMINAL 2 MAKE-IN ______ (50,8 mm) 2 1-3/8 (50,8 mm) (34,9 mm) WF L_ F1 1/2 NPT** DEFLECTOR* STYLE 15or20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) 5/8 (15,9 mm) SPRINKLER FITTING FLUSH 3/8±5/16 I (9,5±7,9 mm) MOUNTING / 1/8 ] SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4 1/2 (12,7 mm) (7,9±6,4 mm) FLUSH 17, MOUNTING / I (3,2 mm) SURFACE ,// / \ CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED POLYESTERC 135°F (57°C) Orange UPRIGHT 155°F (68°C) Red (TY313) 175°F (79°C) Yellow and 1, 2,3,4, 5, 6 PENDENT (TY323) 200°F (93°C) Green 5.6 1/2 in. NPT ________________ 286°F (141°C) Blue 135°F (57°C) Orange PENDENT RECESSED 155°F (68°C) Red (TY323) 1,2,3,4 175°F (79°C) Yellow Figures 4a and 5b 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01 -E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15(1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI72 Page 4 of 4 P/Na 77_XXX_X_XXX I I SIN SPRINKLER FINISH 370 5.6K UPRIGHT (1/2 in.NPT) TY313 1 NATURAL BRASS TEMPERATURE RATINGS 135 I 135-F (57-C) 371 1 5.6K PENDENT (1/2 in.NPT) I TY323 Notes: a. Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-1 PURE WHITE (RAL9010)a POLYESTER I SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) I POLYESTER I 9 I CHROME PLATED 155 155°F(68°C) 175 175°F (79°C) 200 200°F (93°C) 2861 286-F (141-C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 401 02018 Johnson Controls. All rights reserved. All speellicatlons end Other infensation shown were current unol document revision date and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA,e registered trademarks of National Finn Promotion Association; TEFLON is trodnnodr of The Chnrnoors Company FC, LLC Controls