Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5823 NEWTON DR; ; AS120067; Permit
1/24/25, 7:28 AM AS120067 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5823 NEWTON DR Permit Type: SPRINK Parcel No: 2120504300 Lot #: 0 Permit No: AS120067 Status: APPROVED Applied 6/20/2012 Approved: 6/26/2012 Reference No.: Issued: 6/26/2012 PC #: Inspector: Project Title: LIFE TECHNOLOGIES TI ADDITION TO AND RELOCATION OF EXISTING FIRE SPRINKLERS ON 1ST AND 2ND FL Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: LIFE TECHNOLOGIES CORP 5791 VAN ALLEN WAY CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 327 0 327 0 about:blank 1/1 AslzooG - coscoS ..9 00696 6 se....: I Fire Protection 'C•• .• San Diego Branch Office 10695 Treena Street, Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date: 06/18/12 LIFE TECHNOLOGIES T.I. 5823 NEWTON DRIVE CARLSBAD, CA 92008 S JOB #10.CA_5180 All material submitted, maybe substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. 0 Submitted By: M. KELLER Los Angeles 0 San Francisco 0 Orange 0 Fresno • San Diego • Seattle August 13, 2009 Sprinkler 54a MIRAGE® STANDARD AND NIIQNG* ____ TECHNICAL DATA QR CONCEALED PENDENT I SPRINKLER VK462 AND HP I SPRINKLER VK463 (K5.6) I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. t LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD40249 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water Viking Technical Data may be found on working pressures ranging from the minimum.7 psi (0.5 bar) to The Viking Corporation's Web site at 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) http://www.vikinggroupinc.com. sprinklers can be identified by locating "250" stamped on the deflec- The Web site may include a more recent tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 112" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Patents Pending *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C 19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). Sprinkler 54b August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT • SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = 0, 2000/930 = E For example, sprinkler VK463 with a 155 °F/68 °C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M4SW1004, Painted Ivory = M4SW1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 1350/570 UL (139°/59° FM) =A, 1650/740 = C For example, cover 13504 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 0F (57 0C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: S Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a 1/2" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. August 13, 2009 N41vjw4j Sprinkler 54c MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K56 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com 0 Sprinkler NPT ' Nominal Maximum Listings and Approvals4 Base SIN Thread Size K-Factor Water Working (Refer also to Design Criteria on page 54d.) Part No.' Inch mm U.S. metl.ic2 Pressure cULus' FM NYC6 I VdS LPCB j Standard _Response Applications 13503A VK462 1/2' 15 5.6 80.6 175 psi (12 bar) T -- AU1,BX1 -- AY1,CZ1 - -- 14697A VK462 1/2" 15 56 80.6 175 psi (12 bar) [ -- -_-- - AV2,BW2 AV2,BW27 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (l2bar) [AV1,BXI -- AV1,BWI - - AY2,CZ28 14697A VK462 1/2" 15 56J80.6 175 psi (12 bar) jAV1,BX1 -- AV1,BW1 - - - 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 AVI, BX1 -- AV1, BW1 -- -- -- Cover Plate Assembly Temperature Ratings' U -135 "F (57 °C) cULus Listed cover 135041, 136421 (large diameter), Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings or 153941 (square cover plate) FM Approved as 139 °F (59 °C) 1 - Polished Chrome, Brushed Chrome, ° "C A - 155 F ( 68 ) V - 135 "F (57 "C) cULus Listed cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, °F °C) W - 165 (74 cover 135041 or 136421 (large diameter) Brushed Brass, Brushed Copper, oF B - 175 oF (79 C) and 200 (93 C) X - 165 °F (74 °C) cover 135041, 136421 (large diameter), or 153941 Painted White, Painted Ivory, or C - 200 "F (93 C) (square cover plate) Painted Black Y - 135 °F (57 °C) cover 135041 2- Polished Chrome, Painted White Z - 165 T(74 °C) cover 135041 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for an additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. ((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 ((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 °F cover has an orange label. The 165 °F cover has a white label. 1013ainted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 F(57C)cULus Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 'C) Yellow Intermediate 200 °F (93 °C) 150°F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. C-, Sprinkler 54d August 13, 2009 MIRAGE® STANDARD AND I QR CONCEALED PENDENT I S S4J I F(JNc - SPRINKLER VK462 AND HP I SPRINKLER VK463 (K5.6) I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition o f NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Anroval Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8NJ) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. Identiffication of Custom Paint Color: All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint clot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers DO NOT PAINT 3-5/16" (84,1 mm) Figure 2: Square Cover Assembly 15394 Sprinkler Wrench Flat Sprinkler Wrench (Port No. 047W/B)K* is shown) ly )r Ise NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. Sprinkler Frame Arms 2-1/4k (572 mm) diameter opening is required in the ceiling. August 13, 2009 NIKJW*i Sprinkler 54e MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com A 1/2" ratchet required (not ilable from Viking) Step 1: Carefully slide the wrench sideways around the deflector and pins. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats, DO NOT apply more than 25 ft. lbs, of torquie. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Correct Use of Wrenches 1/2 -s, (15 mm) - NPT 2-3/16' (65 mm) 52 mm) (55 mm) MQXIMUM r Minimum '•2s L_i ____ __4 1 3/4" (70 mm) or1 3-5/16" (84.1 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16" (20,6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation April 25, 2008 Sprinkler 51a MICROFAST® AND I N4 I Kj A MicrofastHP® QUICK I RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLERSI The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e103, 1E30401, and 1E30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, and 0786-CPD-40171 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 51d and Design Criteria on page 51e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vlkinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 06661B and 12281. Copper UNS-C19500 for Sprinklers 06665B, 06764B, and 07060. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) Sprinkler 51b April 25, 2008 MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND FIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 1350/680 = A, 155°/68° = B, 175°/79° = D, 2000/930 = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06661BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the 'Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. April 25, 2008 Sprinkler 51c MICROFAST® AND 1 MicrofastHP® QUICK I S4J I 1(1 Fs1G RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLERSI The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) ' Orange ' Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 'F (93 'C) 150 °F (65 'C) Green High 286 'F (141 °C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA0 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Protective Wrench Spriker Fo: ____t C CL p 9=1K:::M Figure 1: Standard SrinkIer Wrench 10896W/B 0 Sprinkler 51d 'JIKING April 25, 2008 MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND L SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com Upright-Standard Orifice 06661B I VK300 1 1/2" 1 15 mm 1 5.6 1 80.6 1 2-3/16 1 56 1 A2 I A3 I A2 I -- -- -- -- 07060 VK345 -- 15 mm 1 5.6 1 80.6 1 2-3/16 1 56 1 -- A3 I A3 I A3 I B312 1 B3'4 Conventional-Standard Orifice 06766B I VK310 I 1/2" 115 mm I 5.6 1 80.6 I 2-3/16 1 56 I A3 I -- I A3 I -- I A3 I B3'2 I B314 Ur!ight-Larçi Orifice ____________________________________________ 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 B312 -- 14817 1 VK350 I -- 20 mm 1 8.0 1 115.2 1 2-5/16 1 59 1 A2 I A3 I A2 I A3 I A3 I B3'2 -- 06764B I VK350 1 1/2" 1 15 mm 1 8.0 1 115.2 1 2-5/16 1 59 1 A2 I -- A2 I A3 I -- - Conventional-Large Orifice 06768B IVK354l 3/4" 120mmI 8.0 I 115.2 [2-5/16] 591 A2 I -- I A3 I -- I A3 18312 1 -- Upright-Small Orifice10 06717131' 1VK325 1/2" 15 mm 1 2.8 1 40.3 2-3/16 1 56 1 A2 I Al I A.2 I -- -- -- -- 0671913" 1VK327 1 1/2" 1 15 mm 1 4.2 1 60.5 1 2-3/16 1 56 1 A2 I -- A2 I - -- -- -- 06931 B1' I VK327 I - 10 mm 1 4.2 1 60.5 1 2-3/16 1 56 1 -- -- -- A3 I El 13 -- 1 Maximum 250 PSI (17 bar) WWP Upriqht-Standard_Orifice Base Part Thread Size Nominal T Overall Length Listings and Approvals3 SIN K-Factor _______________ (Refer also to Design Criteria on page 1e. Number NPT BSP U.S. metric2 Inches mm I cULus4 I FMI NYC- VdS I LPCB I E 0 12281 VK315 1/2" 15 mm 5.6 1 80.6 2-3/16 56 1 A2 -- p.2 -- -- -- -- Upright-Small Orifice10 1228611 I VK340 I 1/2" 115 mm I 2.8 I 40.3 I 2-3/16 56 I A2 I - I A2 Approved Temperature Ratings A - 135 °F (57 °(C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Approved Finishes and 286 °F (141°C) 1 - Brass and Chrome-Enloy® B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - Brass, Chrome-Enloy®, White Polyester' 6, Black Polyester56, C - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141°C) and Black Teflon®5 D - 135 °F (57 °C), 155 °F (68 °C), and 175 °F (79 °C) 3- Brass, Chrome-Enloy®, White Polyester56, and Black Polyester56 E -155°F (68 °C) I Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. '° Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 12(( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 14Ø MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. April 25, 2008 Sprinkler 51e MICROFAST5 AND I MicrofastHP® QUICK iIKI1G RESPONSE UPRIGHT AND I CONVENTIONAL SPRINKLERS) The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com cULus Listing Reauirements: Microfasts and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart f o r i n s t a l l a t i o n in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, r e f e r to the installation guidelines for old style (conventional) sprinklers. FM Aooroval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply re q u i r e m e n t s , hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and 0. standards, whenever applicable. I THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1-1/4" -8") pipe and Sch-40 (1"- 2-1,2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements. Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mex:co and Latin America. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM Al 35, Type E Grade A, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. - Tli.i.i. - NPS Nominal I.D. Wt. WI. (H20 Filled) CRR In; mm Lbs/Ft; kg/rn Lbs/Flg/m 1.049 1.680 2.05 1 26.6 - 3.05 - 11/4 1.380 2.270 2.93 1 _35.r 4.36 - 436 - 11/2 2.720 3.61 1 40 40.9 W 4.0 5,37 2.067 3.650 5.13 1 5-0 52.5 5.4. 7.63 21/2" 2.469 5.790 7.86 1 73 - NPS i;: Nominal I.D. Specifications Wt. Wt. (H20 Filled) CRR In; mm [I Lbs/Fl; kg/rn 11/4 1.442 1.810 2.525 7.0955 -- -. -- 1½" 1.682 2.080 3.04 5.6570 'w T5T 2.157 2.640 4.22 4.5827 54.8 3.9 - 21/2" 2.635 3.530 5.89 3.5196 t'' 66.9 53 8.77 3.260 4.330 7.94 2.5550 82.8T - 6.4 -11.82- 4.260 5.610 11.78 1.6020 108.2 8.3' 753 5.295 7.77 17.33 1.4874 l 34.5-T 11.56 20 6.357 9.290 23.03 1.0251 F_50 161.5 13.8 34.27 ' 8" 8.249 16.490 40.15 1.8365 E: 2L 5975 APPUOVID Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Comments: Customer Service (800) 882-5543 Fax (800) 659-7730 wwwalliedtube sprunklercom 161005 Lathrop Ave, • 11350 Norcom Rd • 2525 N 27th Ave. • 600 Dean Sievers Place Harvey, 1160426 Philadelphia PA 19154 Phoenix AZ 85009 Morrisville PA 19067 @2008-10 Tyco nt All Rights Reserved SW S5 4 1001 Locations: 4 cYallied TUBE & CONDUIT' C.I. THREADED FITTINGS FITTINGS .t Vikh,. q(Xm, Iip Ppothw( (0 * <tm> LISTED LISTED APPROVED For lire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAYIRON PERASTM A126 CLASS B. DIMEN-SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME B16.14. THREADS ARE NPT PER ANSI/ASME 131.20.1. ICAST IIRONIIe1 4:jiiT -DEGREE NOMINAL SIZE (INCH) ITB4 CODE * MAX. WORKING P.S.I. I)IMENSIONS WBGHT A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 1 CB900441 300 1.75 1.75 1.34 11/2 CR90055 300 1.94 1.94 1.80 2 CB90066 1 300 2.25 1 2.25 2.90 21/2 CR90077 300 2.70 1 270 4.75 CAST IRON RED. COUPLING NOMINAL SIZE (INCH) ITEM CODE 6 MAX. WORKING P.S.I. DIM B'lSION WEIGHT EACH PIECE A 1X1/2 CRC031 1 300 1.70 0.82 1X3/4 CRC032 1 300 4 1.70 0.80 CAST IRON RED. 90 DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE 6 MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH B PIECE A 1X1/2 .C11390031 300 1.26 1.36 0.64 1X314 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CR90041 300 1 1.34 1.53 1 0.96 1 1/4X3/4 CB90042 300 1 1.45 1.62 1.13 1 1/4X1 C090043 300 1 158 167 116 I 112x1 1/2 CR90051 300 1 1.41 1.66 1.17 1 1/2x314 CR90052 300 1 152 1.75 128 1 112X1 CR90053 300 1 1.65 1.80 1.51 )1!2X1 1/4 C11390054 300 1.82 1 1.08.1 1.62 ' 2X1/2 CR90061 300 1.49 1.88 2.00 2X3/4 CR90062 300 1.60 1.97 2.05 2X1 CR90063 300 1.73 2.02 2.10 2X1 1/4 CR90064 300 1.90 2.10 2.30 2X1 1/2 1 CR90065 300 2.02 2.16 2.60 Page 38 CAST IRON NOMINAL SIZE (INCH) ITEM CODE STRAIGHT MAX. WORKING P.S.I. TEE DIMENSIONS A B WEIGHTI EACH EACH PIECE 1 CT333 300 1.501 1.50 1.21 1114 C1444 300 1.75 1.75 1.87 11/2 CT555 1 300 1.94 1.94 2.51 2 C1666 300 2.25 225 3.96 2112 CTTfl 300 2.70 2.70 6.45 CASTtIIRON t.-! DEGREE :IIyAY NOMINAL SIZE (INCH) ITEM CODE 6 MAX. WORKING P.S.I. DIMENSIONS A B 1 CB45033 300 1.12 11/4 1.12 i CR45044 300 1.2911/2 1.29 CR45055 300 1.43 2 1.43 CR45066 300 1.66 1.68 CAST IRP.N I NOMINAL I SIZE (INCH) ITEM I CODE PLUGS WORKING P.S.I. MAX. IDlMENSIONj A WEIGHT I EACH PIECE 1/2 CPL001 300 0.94 0.10 3/4 CPLOO2 300 1.07 0.17 1 CPLO03 300 1.25 0.28 11/4 CPLOO4 300 1.36 0.44 11/2 CPLOO5 300 1.45 0.62 - 2 CPLOOS 300 1.56 0.91 LCASTg1IRON IREDUCING I NOMINAL ITEM MAX. DIM B1SIONS WEIGHT EACH (INCI 4 P.S.I. A PIECE 1X1X172 CT331 300 1.26 r 0.95 - 1X1X314 C1332 300 t3T 1.10 1X1I2X1 CT313 300 1.50 0 1.08 1X314X1 CT323 SIZE CODE WOWING - fiB 300 1.50 0 1.18 1XIX1 1/4 CT334 300 1.6 8 1.52 1X1X1 1/2 CT335 300 1.80 5 1.73 11/4X1X112 CT4313001.34 531.171 1/4X1X3/4 CT432 300 1.45 62 1.38 1 II4X1XI CT433 300 T58 57 1.47 1114X1X1 1/4 CT434 300 115 75 1.80 1 1143(111 1/2 CT435 300 1.88 1.80 1.82 2.05 1 114X1 114X112 CT441 300 13 1.34 1.53 1.37 1 114X1 114X314 CT442 300 1.45 1.62 --T34- 1 11491 114X1 7T443 300 1.58 1.58 -rr 1.65 1 114X1 114X1 1/2 CT445 300 1.88 1.88 12 2.21 I 114X1 114X2 CT446 300 2.10 2W 1W 255 1 112X1X112 CT531 300 1.41 1.34 1 1.65 1.41 1 1/2X1X314 CT532 300 1.52 1.37 1.'6 165 1 172X1X1 Cr533 - 300 1.65 1.50 180 1.65 I 112X1X1 1/4 CT534 300 1.82 1.67 tr 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 T 2.30 1 112X1 1/4X112 CT541 300 1.41 Th L66 1.58 I 112X1 1I4X314 CT542 300 1 1.52 T4 1.75 1.72 I 112)11 114)11 CT543 300 1.65 1.80 1.85 1 1/2x1 114x1 1/4 CT544 300 1.82 t751 1.88 2.22 I 1/2x1 114x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 112X1 1/4X2 CT546 300 2.16 2.10 2.02 ---2-W I 112X1 112X1/2 CT551 300 1.41 1.41 166 1.76 1 112X1 112X3/4 CT552 300 ir 1.52 1.75 1.87 1 112X1 1/2X1 CT553 300 165 1.65 1.80 1.94 I 112X1 112X1 1/4 C1554 300 1.82 182 1.88 2.29 I 112X1 1t2X2 C1556 300 2.16 2.16 :: 3.28 2X1X2 CT636 300 225 2.02 2.25 2X1 1/4X2 CT646 300 225 2.10 2X1 112X112 CT6S1 300 TW2X11/2X314 1.49 1.41 A T652 300 1 £0 1.52 1.97 2X1 1/2X1 CT653 300 1.73 2.02 2X1 1/2X1 1/4 CT654 300 1.90 2.10 2X1 112X1 112 CT655 300 1.49 1.41 1.88 2.24 2X1 1/21ff CT656 300 2.25 TW 2.25 3.75 2X2X1/2 C1661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 C1663 1 300 1.73 1.73 2.02 2.97 - 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 112 C1665 300 2.02 1 2.02 2.16 3.72 2x2x2 1/2 CT667 I 300 2.60 1 2.60 1 2.39 1 5.10 • 0 1) C.I. THREADED FITTINGS . FITTINGS )~.P. i.!%kvPkp / LEft LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON NOMINAL SIZE (INCH) CROSS ITEM I MAX. CODE WORKING 4 P.S.I. DIMBISIONS A B WEIGHT EACH PIECE 1 CX033 300 1.50 1 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 111/2 CX055 300 1.94 1.94 3.10 2 0X066 300 2.25 00 1 114X1 CX043 300 1.58 1.6705 1 1/2X1 CX053 300 1.65 2.2512.75 1.8040 2X1 CX063 300 1.73 2.02 Page 39 FireLock® Outlet-T Read and understand all instructions before attempting to install any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in serious personal injury and/or property damage. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Failure to follow this instruction could result in serious personal injury and/or property damage. The Style 922 FireLock Outlet-T is designed for direct connection of sprinkler heads, drop nipples, sprigs, drains, gauges, and other outlet products. The Style 922 FireLock Outlet-I is UL Listed and FM Approved up to 300 psi/2068kPa and VdS Approved up to 16 Bar/232 psi at ambient temperatures that are typical for fire protection systems. PRODUCT DATA z_1 114 ½ 1146 1.30 1.83 1.10 3.87 2.56 1.0 Yf T 32 15 30.2 330 Mi !465 1 0.45 w 20 30.2 .13.2.5 46.5 25 30.2 1 38.6 55.4 27.9 98.3 65.0 0.54 I i6 ½ 1A6 1.42 1 1.95 1.22 4.08 2.56 12 40 - 15 30.2 36.1 49.5 31.0 103.6 65.0 - 0.54 ~ 1A6 1.40 1.95 1.22 4.08 2.56 J 1.2 20 302 353 495 310 103 -653 054 1 13/16 1.64 1 2.30 1.22 4.08 2.56 1.3 25 7 0.59 2 1/2 13/16 1.66 i 2.19 - 1.46 1 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 1 116.8 65.0 0.59 .-/--._-. 3/4 164, 1.64 2.19 1 1.46 4.60 2.56 1.4 20 30.2 1 41.7 55.6 37.1 1 116.8 65.0 0.64 1 13/1. 1.88 2.54 -i 1.46 1 4.6T 2.56 1.5 25 3a2 47.8 64.5 37.1 116.8 I652 0.68 21/2 1/2 11' 1.91 2.44 1.71 5.40 1 2.56 1.6 65 15 30.2 485 62.0 43.4 1372 65.0 0.73 3/ 1 '/ 1.89 2.44 1.71 5.40 2.56 1.6 20 30-2483 L_62-° _4;4_ i?J 65.9__ 073 1 19~ 1 2.13 2.79 1.71 __ 5.40 2.56 I 1.6 25 30.2 _ 54.1 70.9 43.4 137.2 65.0 0.73 1/2 19¼ 1.91 2.44 1.71 550 256 1.6 76,1 mm x 15 30.2 48.5--1-- _ 14 1i4 1.89 2.44 1.71 5.50 f 2.56 1.6 .20 302 48.0 62.0 43.4 139.7 1 65.0 0.73 1 - 1 3A6 2.13 2.79 1.71 5.50 1 2.56 1.7 25. 302 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (Optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinkler heads, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com - - vIcTAULIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2004 vlcTAuuc COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. •ctaul.c REV_C 1-922_I 1-922 INSTALLATION INSTRUCTIONS . FireLock® Outlet-T STYLE 922 PIPE PREPARATION NOTICE Victaulic hole cutting tools are recommended for proper hole preparation. Cut a hole on the centerline of the pipe. Refer to table on page 1 for hole requirements. 2. Insert a bolt into the outlet housing and lower housing, and thread a nut loosely onto the bolt (nut should be flush with end of bolt) to allow for the swing-over" feature, as shown above. C 4. Insert the other track bolt into the outlet housing and lower housing. Install the nut finger-tight. \4taUIic REV_C www.victaulic.com VICTAuLIC is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2004 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. l-922_2 Exaggerated for clarity Ensure that a 1/2-inch/13-mm area around the hole is clean, smooth, and free from indentations and/or projections that could affect gasket sealing (refer to the sketch above). Remove any burrs and sharp or rough edges from the hole that might affect assem- bly, proper seating of the locating collar, flow from the outlet, or gasket seating. INSTALLATION 3. Install the outlet housing onto the pipe by centering the locating collar in the hole. To check for proper engagement, slide the outlet housing back and forth while pushing down. A properly positioned outlet housing can be moved only a small amount in any direction. 3a. Rotate the lower housing around the pipe, while holding the outlet housing in place to make sure the locating collar remains seated properly in the hole. 1. Install the gasket into the gasket pocket, as shown above. Press the gasket along the full circumference to ensure that it fully seats in the gasket pocket. DO NOT LUBRICATE THE GASKET. 1-922 INSTALLATION INSTRUCTIONS FireLock® Outlet-T STYLE 922 5. Tighten the nuts evenly to an approximate torque value of 20ft-lbs/27.1-Nom to ensure proper gasket compression. NOTE: To avoid over-tightening the nuts, use a wrench with a maximum length of 8 inches/200mm. DO NOT over-tighten the nuts. The outlet housing, near the gasket, should not make metal-to-metal contact with the pipe. In addition, a small gap is expected between the outlet housing and the lower housing, as shown above. DO NOT over-tighten the nuts. Over-tightening the nuts can over-compress the gasket and distort the outlet housing and lower housing. Over-tightening does not enhance product per- formance. Failure to follow this instruction could cause product failure, resulting in serious personal injury and/or property damage. www.victaulic.com VIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2004 VICTAUC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVC Ac-t-sulid 1-9223 STYLE 922 I 1I1II1II1IlIIIIIlIIIIII liii ItlIllIlIllEl WCAS-65GJLA For complete contact information, visit www.victaulic.com 1-922 3393 REV C Z100922000 UPDATED 3/2004 vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02004 vicrAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. X04—c—tu —ul i C~ -922 c®us usia Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed gjy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 /1 'I 1/ .. 1; .-'' OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.con, Fig. 78 - All Steel Ceiling Plate c®usumo Size Range - 3/8" rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2-2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw Wood 21/2 -4 2 1/4 x 1½ wood screws' Wood 1/2 -2 2 1/4 x 1 tek screws Metal (18 gauge) 1/2-2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw Wood 1/2 -2 2 #14 x 2 A-point-hex-washer-head sheet metal screw Wood thru 5/8' gyp board * No pre-drilling Dimensions • Weights Max. Rec. Approx. A B C D E Pipe Size Load Lbs.* WtJ100 1/2-2 3 21/8 11/8 5/16 3/8 150 15 5 - 6 1Consult factory for data * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 .PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com Component of State of California OSHPD Approved Seismic Restraints System -- Size Range - Secures 3/8" thru 7/8" rod in 1° increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCQ Seismic Restraint Systems Guidelines Finish - Electro Galvanized I Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number FIC Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 - All Thread Rod Full Lncith Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1112 13800 510 M OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 2" Fig. 200 - "Trimline" Fig. 200R (Import) - Adjustable Band Hanger "Trimline" Adjustable Band Hanger w/Retainer Ring C®US LIED Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 ' thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or10mm 31A 2/8 400 11 3/4 3/8 8mm or 10mm 31/8 21h 400 11 1 3/8 8mm or 10mm 3/8 2/8 400 12 11/4 3/8 8mm or 10mm 33/4 27A 400 13 1½ 3/8 8mm or 10mm 3/e 27A 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21/2 3/8 10mm 55A 41A 600 27 3 3/8 10mm 57A 4 600 29 3½ 3/8 10mm 7/8 51/4 600 34 . 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951-737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www,tolco.com 25 125 25 125 9~amffl yg Not less than 2' nominal width (1-112') up Is 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe Floor Joist Minimum 2-1/2' from bottom for branch tines. Minimum 3' frsm hot- II tom for mainlines. Exception: This requirement shall not apply t02' or thicker nailing strips resting on top of steel beams. A~ No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Wvith a video domonshalioo vi wwwitwbuiidex.com -u 1/4' 8019957 3j8' 8020957 e 3/8 8021957 3/8 8073925 3/8" 8022925 #14 SW Red I - 3/8 8023925 Nut Driver Part #8114910 * May require pre-drilling; csnuut joist manufacturer. SWG 200 1/4s 2' 1725 (Fir) 25 125 SWG 10 114x1' 622f ir). 300 .25 125 SWG 20 1/4x2" 1725 (Fir) 1050 25 125 SWG 20-SS 1/4x2' 1725r. 850 25 125 SWG 25-380 3/8 x 2-1/2 2249 (Fir) 1500 25 125 'Eliminates distortion of threaded rod. 'Accommodates up to 3 %" x 12 pitch roof. 'Allows 170 defection from vertical. 'Saves time from traditional methods. Reduces installation costs. 'Made in the U.S.A. # 14 Black - ti,'' 3/8' 8139957 SH-GST 20 1/4 x 2' 1257 (Fir) 1050 1475 5 Driver - 141( /8t{GjT 1 ut 78J 14Th - 1903 Dim. Lumber GL 3/8' 8269957 SH-GST/CST20 1500 5/16x1-3/4' 1406@45'off vertical , 850 Dim. Lumber © 903Dm Lumer ,1127 8303957 SI-I GSTiCST2 0 L 5/16x 1-214 1406 @S overlIcal Dim Lumber May require pre-drilling; consul joist manufacturer. #14SHOrange Nut Driver Part #8273910 APPROVALS 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 1957 GST2 3/8" VèticaI 2-1/2' 850 1-1i 4" 145 1-172_j] 8068925 GST2O-SS 3/8' Vertical 2-1/2" 850 1-1/2' [j957G530 3/8' Vertical 41 - 1809 111)2' 4' 1475 1-1/2' - 8009925 GST25-380 3/8' Vertical 4' 1500 1-1/2' [I925 SWG 25-380 3/8' _Hoñzontl 3-112" - 1500 1-1/2" 8021957 SWG 20 3/8' Horizontal 2-1/2" - 3"" 1050 1-1/2 Etii?WG20SS 3/8' . Horizontal 2-1/2' 850 8269957 SH-GST/CST 20 3/8' 45" Angle off Vertical 2-1/2" 850 1-1/2 L8269957 - SH-GSI/CST2O 3i8 45" Angle off Vertical 4" 150 1-1/2" 8139957 SH-GST2O 3/8" 17' Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2° 8037957 DSTR 1-1/2 3/8" Vertical 4' 1500 .035" 4' 1475 .105" L80.9957_ DSTR 516 3/8° VertIcal. 4. 1500 ,037" - 4' 1475 .105' 8045957 DST 516 3/8' Vertical 1500 .188" 4" 1475 .188" E8o469s7TEK50 -. 3/ Vertical 4" ioo_ ,250" 4" 1475 8055957 SWOR 1 - 3/8' Horizontal 4' 1500 .037" 4' 1475 .060" LQ695L. SWDR 516 3/8" l-lorizontal 4' - 1500 .037" 41 1475 - .060" J 8054957 SWOR 1-1/2 3/8" - Horizontal 4' 1500 .037" 4" 1475 .060" L8137957_sH-I1 3/8'L .7°Ange off Vertical 4"- 1500 - _..oW 4'T 1475 8268957 SH-TEK 50 3/8' Vertical 70' Angle off Vertical 2-1/2" 4" 850 1500 1 8150 XP 2O ' Vertical .°. 2-1/2"• ., 850 .0J ____ 8153922 XP 35 3/8" Vertical 4" 1500 .060" 94 2 SXP 20 _3/i" Vertical ic45" 2"iiL° .029" 82959.22 8295922 SXP 35 3/8' Vertical orupts89' 3-1/2" 1250 .060" 2" 635 .029" SAMMYS FOR QONTE 'PIPE HANGER LQ9957 CST 2o 3/8' _Vertical __4'1475 -3000 8061957 SWC 20 3/8" Horizontal . 4" 1475 3000 8150922 XP 20 /8' Vertical 2-1/2' _850 _Pce-ral3000ps1 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC :5 35 PCF (lbs/tt°) 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" [922 --XP200 1/4°, Vertical 07' 11 - 8294922 SXP 20 3/8" Vertical 170 .027" 45" 80 .027" 8295922 SXP 35 3/8" VértTcal 250 90* 517 tO60' 80 8293957 SWXP35 3/8" Horizontal 80 .060' 8153922 XP 35 3/8" Vertical 500 .060' Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit I29492Z S20 3/8° Vertical 293 .027'Max 4 trade Size EMT, W" and IITC & 5 trade size rid 8295922 SXP 35 3/8" Vertical 500 .060' Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod Complies w/ NEC Standards Nominal Decimal Equivalent .030" .036' 'SWG 25-380 Maximum pipe size in composite wood mist allowed by UL is 3-1/2' "SWG 25-380 Maximum pipe size in wood limber or joist allowed by UL is 4' '"SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" '"SWG 20 Maximum pipe size in wood timber or joist allowed by UL 1s3' .048' .060' .075" .105" .125' .188' .250' 1)1 compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement 5 limes weight of water-filled schedule 40 pipe plus 250 pounds. The AGE Manufacturing Inc. Model 10IIA TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 101 IA complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 101 IA TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 34' to 2' NPT and BSPT, with all specifiable orifice sizes 3/a" (2.8K), 7A6" (4.2K), ½' (5.6K), 17/32" (8.0K), 5/' (11.2K, ELO), 3%" (14.0K, ESER), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). The included ULJFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. - Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRAIN is a registered trademark of AGE Manufacturing Inc. cs1011A 10/09 DIMENSIONS MODEL 1011 - FRONT VIEW Orifice Size Available: /8", 7A6", ½", 17,52", ELO (%)*, ESFR (3/4)* & Q5** SIZE A B C D E F G H 76" 1½" 23/16 35W 33/&' 113/16" 4A6" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79A" 1/" 23A6' 3/8" 3/8" 11/6" 4A6" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715A6" 111A6" 29A6" 41/4" 35/8" 11 /6" 59A6" 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½' 815/16" 113A6" 31/4" 51/16" 3 /8" 25W 8¼" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815A6' 113A6" 31/4 51A6" 3/8" 25A" 81/4" 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 11/4" to 2" size units only ** Available on 1112" and 2" size units only THE MODEL 1011 PROVIDES ALL OF THE FOLLOWING... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 . & 8.16.2.4.3 Drain connections, interior sectional or floor control valve(s) - shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve MODEL 1011 - PLAN VIEW MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: