HomeMy WebLinkAbout6221 METROPOLITAN ST; ; AS100010; Permit12/13/24, 3:59 PM ASI000I0 Permit Data City of Carlsbad Sprinkler Permit Permit No: ASI000I0 6221 Job Address: METROPOLITAN ST Permit Type: SPRINK Parcel No: 2132600100 Lot #: 0 Reference No.: Status: ISSUED Applied 1/27/2010 Approved: 1/27/2010 Issued: 1/27/2010 PC #: Inspector: Project Title: MICHELE LEE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 City of Carlsbad 02-09-2010 Fire Department Permit Permit No: ASI000I0 Job Address: 6221 METROPOLITAN ST CBAD St: 200 Permit Type: SPRINK Subtype: TI Parcel No: 2132600100 Lot #: 0 Fire Dept Ref: ASI 0001 Building Permit#: CB091705 Location: Project Title: MICHELE LEE Description: T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Contractor: AZTEC FIRE & SAFETY Phone: 619-464-5625 8107 COMMERCIAL ST Fax: LA MESA, CA 91942 Status: ISSUED Applied: 01/27/2010 Issued: 01/27/2010 Entered By: BSW Total Fees: $130.00 Total Payments To Date: $0.00 # of Systems 1 # of Additional Risers or Floors 0 Plan Check Fee $65.00 Additional Plan Check Fee $0.00 #of Heads 0 $0.00 Permit Fee $65.00 Additional Permit Fee $0.00 Re-Inspection Fee 0 $0.00 ByPass Meter Fee $0.00 ByPass Addtl Meter Fee $0.00 Other $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $130.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. Bulletin 014 Rev. C Reliable Model Fl FR Series Quick Response Standard Spray Model F1 FR 56 Sprinkler Types Standard Upright Standard Pendent Conventional Model Fl FR 56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Model Fl FR 56 Concealed Sprinkler Types Standard Pendent Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) - Light Hazard - No Limitations - Ordinary Hazard Group 1 & 2, wet systems only. Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1FR Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decora- tive sprinkler. The Models Fl FR Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FIR Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a pre- cisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The balance of parts are made of brass, copper and be- ryllium nickel. At normal temperatures, the glass bulb contains the flu- id in both the liquid and vapor phases. The vapor phase can he seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push Out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflec- tor to distribute the discharging water. Upright Pendent Conventional Recessed Pendent/Fl/F2 4 -.----- t ,, Recessed Concealed Pendent Pendent/FP FILE COPY Application Quick response sprinklers are used in fixed tire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should riot he intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Identification Number Nominal Thread Nominal K Factor Sprinkler Approval (SIN) Orifice Size Height Organization US Metric . Upright I Pendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position T) l24 LRA1425 "RAi4i4 80 2.25"( Conventional-Install in Upright or Pendent Position .._1L..LI).... cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. Upright Pendent Conventional Model Fl FR 56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Sprinkler Identification Number Height (SIN) US Metric ½ (15mm) ½" NPT(RV2) 5.6 80 2.25 (57mm)L RA1414 i: Refer to escutcheon data table for approvals and dimensions. 2 I IOIIOIS 14,92-1 VA - TURN Co""R r -- .' /2 sEDuces UNM 716,17 II1ENEN 1022 I FACE OF FIrTINC TO~') 2 5/8 0/A. [66. 7rs,s] ..... HOLE IN CEILING 2 5/I6 014. [58.751,,-] CUP I I" X /./2 REDUCER L FACF OF FACE OF !J CRUNr L TO iIT AIFNT :: (1) REFER TO FP ESCUTCHEON DATA TARE FOR APPROVALS AND DIMENSIONS. Model F1FR 56/Fl:1 H 2 27/J2 01.1. ] 014FC01 (i) RICER IC Cl A F. CSCI.'TCHEON aSIA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR 56/Fl or F2 2. Model Fl FR Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K" Factor Nominal -.-.- .--.---.-...-- Thread Temp. Rating --------.- Max. Ambi- Bulb Sprinkler Orifice US Metric Size d Moe Sprinkler Cover ent Temp Color Approvals Identification Number(SIN) ½" (15mm) 5.6 80 ½' NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 155°F/68°C 135°F/571C 1000F/38CC Red 1, 2,4/1) RA 1414 ½' (15mm) 5.6 80 ½' NPT F1FR 175°F/79°C 165°F/74°C 100°F/380C Yellow 11.2- RA1414 ½" (15mm) 5.6 80 ½" NPT FlEA 200°F/93°C 165°F/74°C 100°F/38°C Green 1,2 R. A.1.4.1.4 For VdS only = 155°FI68C Norbuib and 1/2' [127mm] adjustment. 1" 1/2' REDUCING TEE OR ELBOW ii 2 5/16 0/A - HOLE IN CEILING CUP I 1/2" MAX. FACE OF FITTING - - TO FACE OF CEILING CEILING 1 COVER ADJUSTMENT 15/16" COVER PLATE' 4555M8 3 5/16 0/A. SPRINKLER 1/2" ADJUSTMENT . Or1O Figure 1 Installation Aid A protective cap is included for use during installation. irnpi1ant The F.1FR 56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR 56 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to he used with the Model F1FR 56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR 56 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for installing F1FR 56 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can he obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. The Model Fl FR 56! COP Concealed Sprinkler uses the ½" orifice, ½" NPT (R1/2), 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C) Model F1FR 56 Pendent I'. I/2 REDUCING TEE OR ELBOW ___ A 2 5/1& "DM- H _ HOLE IN CEILING CU FACE OF FITTING TO FACE OF CELL/NC CEILING I -' 1MENSION 5116- MAX, 314 COVERADX'T.E NJ COVER PLATE L/ ASSEMBLY 3 5/16 OIA SPRINKLER 5/16" ADJUSTMENT 01-02 Figure 2 Sprinkler with a threaded Model COP cup which is fac- tory attached to the sprinkler. The assembly is complet- ed by the installation of the attractive, low profile, 135°F (57°O) or 165°F (74°C) rated Model COP push on cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either '/2 (13mm) or (8mm) of cover adjustment. Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon" based thread sealant should be applied to the sprinkler threads only. The Model R01 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. 3 After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate/cup assembly with the Model F1FR 56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place, REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Sprinkler Max Ambient Classification +em Bulb Color Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F(66°C) Yellow Intermediate 93 200 150°F (66°C) Green High 141 286 225°F (107°C) Blue Not available for recessed sprinklers. Escutcheon Data Face ofFrthng Esc eon Approvals AdjustmentMcdel Dimension to Ceiling or Wall Dimension Fl 1 3 4 Max Recess 1W (38.lrmi) 116' - Min Recess 19. J..:tffti F"' 1 3 4 Max Recess 1 Y2' (38.lm) '"' Min Recess 1 (2Emn) (5mm- 17rrrn) FF' ,h<rr/ 1,4 Max Recessed /i6' (llni'n) 1'k" (38.lnrn) ThIeff..............................Mi5c.ed ,4g_ j5Ani'n) Maintenance The Models F1FR 56 and F1FR 56 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other clean- ing fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should he maintained to allow quick re- placement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for dam- age to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate Bronze Brass Chrome Plated Chrome Chrome White Polyester Plated White Coated °XE) White Painted Special - Application Finishes Sprinkler Escutcheon F Cover plate Bright Brass ' Bright Brass Bright Brass Black Plated Black Plated Satin Black Paint 2) Black Paint Off White Off White 2) Off White Black Paint SatinChrome SatinChrome BlackPlated 1) Other finishes and colors are available on special order. Consult the factory for details. (2) cULus Listed only. 3) 200°F (93°C) maximum. ° cULus listed "corrosion resistance" applies to SIN Numbers RA1425 (Upright) and RA1414 (Pendent). FM Approvals finish as 'Polyester coated" applies to SIN Number RA1414 (Pendent). Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Li. Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model F1FR 56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled G el- ,le (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EU. Printed in U.S.A 12/09 P/N 99999/0300