HomeMy WebLinkAbout6221 METROPOLITAN ST; ; AS100010; Permit12/13/24, 3:59 PM ASI000I0 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: ASI000I0
6221
Job Address:
METROPOLITAN ST
Permit Type: SPRINK
Parcel No: 2132600100
Lot #: 0
Reference No.:
Status: ISSUED
Applied 1/27/2010
Approved: 1/27/2010
Issued: 1/27/2010
PC #: Inspector:
Project Title: MICHELE LEE T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant: Owner:
Fees ($) Add'l Fees ($) Total ($) Balance ($)
130 0 130 0
about:blank 1/1
City of Carlsbad
02-09-2010 Fire Department Permit Permit No: ASI000I0
Job Address: 6221 METROPOLITAN ST CBAD St: 200
Permit Type: SPRINK Subtype: TI
Parcel No: 2132600100 Lot #: 0
Fire Dept Ref: ASI 0001 Building Permit#: CB091705
Location:
Project Title: MICHELE LEE
Description: T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS
Contractor:
AZTEC FIRE & SAFETY Phone: 619-464-5625
8107 COMMERCIAL ST Fax:
LA MESA, CA
91942
Status: ISSUED
Applied: 01/27/2010
Issued: 01/27/2010
Entered By: BSW
Total Fees: $130.00 Total Payments To Date: $0.00
# of Systems 1
# of Additional Risers or Floors 0
Plan Check Fee $65.00
Additional Plan Check Fee $0.00
#of Heads 0 $0.00
Permit Fee $65.00
Additional Permit Fee $0.00
Re-Inspection Fee 0 $0.00
ByPass Meter Fee $0.00
ByPass Addtl Meter Fee $0.00
Other $0.00
Additional Fees $0.00
TOTAL PERMIT FEES $130.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
Bulletin 014 Rev. C
Reliable Model Fl FR Series
Quick Response
Standard Spray
Model F1 FR 56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Model Fl FR 56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Model Fl FR 56 Concealed Sprinkler Types
Standard Pendent
Listing & Approvals
Underwriters Laboratories Inc. and Certified for
Canada (cULus).
Factory Mutual Approvals (FM)
- Light Hazard - No Limitations
- Ordinary Hazard Group 1 & 2, wet systems only.
Loss Prevention Council (LPCB, UK)
VdS SchadenverhUtung GmbH
UL Listing Category
Sprinklers, Automatic & Open (VNlV)
Quick Response Sprinkler
Product Description
Reliable Models F1FR Series Sprinklers are quick re-
sponse sprinklers which combine the durability of a stan-
dard sprinkler with the attractive low profile of a decora-
tive sprinkler.
The Models Fl FR Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers
have demonstrated response times in laboratory tests
which are five to ten times faster than standard response
sprinklers. This quick response enables the Model F1 FIR
Series sprinklers to apply water to a fire much faster than
standard sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside a pre-
cisely manufactured glass capsule. This glass bulb is
specially constructed to provide fast thermal response.
The balance of parts are made of brass, copper and be-
ryllium nickel.
At normal temperatures, the glass bulb contains the flu-
id in both the liquid and vapor phases. The vapor phase
can he seen as a small bubble. As heat is applied, the
liquid expands, forcing the bubble smaller and smaller as
the liquid pressure increases. Continued heating forces
the liquid to push Out against the bulb, causing the glass
to shatter, opening the waterway and allowing the deflec-
tor to distribute the discharging water.
Upright Pendent
Conventional Recessed
Pendent/Fl/F2
4
-.-----
t
,,
Recessed Concealed Pendent
Pendent/FP
FILE COPY
Application
Quick response sprinklers are used in fixed tire protec-
tion systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflec-
tor style and sprinkler type are in accordance with the lat-
est published standards of the National Fire Protection As-
sociation or the approving Authority Having Jurisdiction.
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should riot he intermixed.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler Identification Number
Nominal Thread Nominal K Factor Sprinkler Approval (SIN)
Orifice Size Height Organization
US Metric . Upright I Pendent
Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position
T) l24 LRA1425 "RAi4i4 80 2.25"(
Conventional-Install in Upright or Pendent Position
.._1L..LI)....
cULus listed corrosion resistant (Polyester coated) sprinkler.
(2) Polyester coated FM approved sprinkler.
Upright Pendent Conventional
Model Fl FR 56 Quick Response Recessed Pendent Sprinkler
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler Sprinkler Identification Number
Height (SIN) US Metric
½ (15mm) ½" NPT(RV2) 5.6 80 2.25 (57mm)L RA1414
i: Refer to escutcheon data table for approvals and dimensions.
2 I IOIIOIS
14,92-1
VA -
TURN Co""R
r
--
.' /2 sEDuces
UNM 716,17
II1ENEN 1022 I
FACE OF FIrTINC TO~')
2 5/8 0/A. [66. 7rs,s] .....
HOLE IN CEILING
2 5/I6 014. [58.751,,-]
CUP
I I" X /./2 REDUCER
L
FACF OF
FACE OF
!J
CRUNr
L
TO
iIT AIFNT
::
(1) REFER TO FP ESCUTCHEON DATA TARE FOR APPROVALS AND DIMENSIONS.
Model F1FR 56/Fl:1
H 2 27/J2 01.1. ] 014FC01
(i) RICER IC Cl A F. CSCI.'TCHEON aSIA TABLE FOR APPROVALS AND DIMENSIONS.
Model F1FR 56/Fl or F2
2.
Model Fl FR Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
"K" Factor
Nominal -.-.- .--.---.-...-- Thread Temp. Rating
--------.- Max. Ambi- Bulb Sprinkler
Orifice US Metric Size d Moe
Sprinkler Cover ent Temp Color Approvals Identification
Number(SIN)
½" (15mm) 5.6 80 ½' NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414
½" (15mm) 5.6 80 ½" NPT F1FR 155°F/68°C 135°F/571C 1000F/38CC Red 1, 2,4/1) RA 1414
½' (15mm) 5.6 80 ½' NPT F1FR 175°F/79°C 165°F/74°C 100°F/380C Yellow 11.2- RA1414
½" (15mm) 5.6 80 ½" NPT FlEA 200°F/93°C 165°F/74°C 100°F/38°C Green 1,2 R. A.1.4.1.4
For VdS only = 155°FI68C Norbuib and 1/2' [127mm] adjustment.
1" 1/2' REDUCING
TEE OR ELBOW
ii
2 5/16 0/A - HOLE IN CEILING
CUP
I 1/2" MAX.
FACE OF FITTING
- -
TO FACE OF CEILING
CEILING
1
COVER ADJUSTMENT 15/16"
COVER PLATE'
4555M8 3 5/16 0/A.
SPRINKLER
1/2" ADJUSTMENT . Or1O
Figure 1
Installation Aid
A protective cap is included for use during installation.
irnpi1ant The F.1FR 56 Sprinkler with Model COP cover
plate is not an FM Approved combination.
Installation
Quick response sprinklers are intended for installation
as specified in NFPA 13. Quick response sprinklers and
standard response sprinklers should not be intermixed.
The Model F1FR 56 Recessed Quick Response Sprin-
klers are to be installed as shown. The Model Fl or F2 Es-
cutcheons illustrated are the only recessed escutcheons
to he used with the Model F1FR 56 Sprinklers. The use
of any other recessed escutcheon will void all approvals
and negate all warranties.
When installing Model F1FR 56 Sprinklers, use the
Model D Sprinkler Wrench. Use the Model GFR2 Wrench
for installing F1FR 56 Recessed Pendent Sprinklers. Any
other type of wrench may damage these sprinklers.
NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can
he obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m).
Do not tighten sprinklers over maximum recommended
torque. It may cause leakage or impairment of the sprin-
klers.
The Model Fl FR 56! COP Concealed Sprinkler uses the
½" orifice, ½" NPT (R1/2), 135°F (57°C), 155°F (68°C),
175°F (79°C) or 200°F (93°C) Model F1FR 56 Pendent
I'. I/2 REDUCING
TEE OR ELBOW
___
A
2 5/1& "DM- H _
HOLE IN CEILING
CU
FACE OF FITTING
TO FACE OF CELL/NC
CEILING I -'
1MENSION
5116- MAX, 314
COVERADX'T.E
NJ
COVER PLATE L/
ASSEMBLY 3 5/16 OIA
SPRINKLER
5/16" ADJUSTMENT 01-02
Figure 2
Sprinkler with a threaded Model COP cup which is fac-
tory attached to the sprinkler. The assembly is complet-
ed by the installation of the attractive, low profile, 135°F
(57°O) or 165°F (74°C) rated Model COP push on cover
plate assembly. The cover plate and sprinkler cup as-
semblies are joined using a cover plate skirt with flexible
tabs for threaded engagement. A choice of two cover
plate assemblies provide either '/2 (13mm) or (8mm)
of cover adjustment.
Do not install these sprinklers in ceiling which have
positive pressure in the space above.
After a 2/8" (67mm) diameter hole is cut in the ceil-
ing, the sprinkler is easily installed with the Model RO1
Wrench. A Teflon" based thread sealant should be
applied to the sprinkler threads only. The Model R01
Wrench is then used to engage the sprinkler wrenching
surfaces and to install the sprinkler in the fitting. When
inserting or removing the wrench from the sprinkler/cup
assembly, care should be taken to prevent damage to
the sprinkler. DO NOT WRENCH ON ANY OTHER PART
OF THE SPRINKLER. The cover plate is then pushed
onto the cup. Final adjustment is made by hand turning
the cover plate until the skirt flange makes full contact
with the ceiling. Cover plate removal requires turning in
the counter clockwise direction.
3
After installation, inspect all sprinklers to ensure that there
is a gap between the cover plate and ceiling and that the
four cup slots are open and free from any air flow impedi-
ment to the space above.
Concealed cover plate/cup assemblies are listed only
for use with specific sprinklers. The use of any other con-
cealed cover plate/cup assembly with the Model F1FR 56
Pendent Sprinkler or the use of the Model CCP Concealed
cover plate assembly on any sprinkler with which it is not
specifically listed my prevent good fire protection and will
void all guarantees, warranties, listings and approvals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and in-
stallation. REMOVE THIS PROTECTION AT THE TIME THE
SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
PROTECTION. Removal of the protectors before this time
may leave the bulb vulnerable to damage. RASCO wrench-
es are designed to install sprinklers when covers are in
place, REMOVE PROTECTORS BY UNDOING THE CLASP
BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO-
TECTORS.
Temperature Ratings
Sprinkler Max Ambient Classification +em Bulb Color
Ordinary 57 135 100°F (38°C) Orange
Ordinary 68 155 100°F (38°C) Red
Intermediate 79 175 150°F(66°C) Yellow
Intermediate 93 200 150°F (66°C) Green
High 141 286 225°F (107°C) Blue
Not available for recessed sprinklers.
Escutcheon Data
Face ofFrthng Esc eon Approvals AdjustmentMcdel Dimension to Ceiling or
Wall Dimension
Fl 1 3 4 Max Recess 1W (38.lrmi) 116' -
Min Recess 19. J..:tffti
F"' 1 3 4 Max Recess 1 Y2' (38.lm)
'"' Min Recess 1 (2Emn) (5mm- 17rrrn)
FF' ,h<rr/ 1,4 Max Recessed /i6' (llni'n) 1'k" (38.lnrn)
ThIeff..............................Mi5c.ed ,4g_ j5Ani'n)
Maintenance
The Models F1FR 56 and F1FR 56 Recessed Sprinklers
should be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean
sprinklers with soap and water, ammonia or any other clean-
ing fluids. Remove dust by using a soft brush or gentle
vacuuming. Remove any sprinkler which has been painted
(other than factory applied) or damaged in any way. A stock
of spare sprinklers should he maintained to allow quick re-
placement of damaged or operated sprinklers. Prior to
installation, sprinklers should be maintained in the original
cartons and packaging to minimize the potential for dam-
age to sprinklers that would cause improper operation or
non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Finishes (1)
Standard Finishes
Sprinkler Escutcheon Cover plate
Bronze Brass
Chrome Plated Chrome Chrome
White Polyester Plated White
Coated °XE) White Painted
Special - Application Finishes
Sprinkler Escutcheon F Cover plate
Bright Brass ' Bright Brass Bright Brass
Black Plated Black Plated Satin
Black Paint 2) Black Paint Off White
Off White 2) Off White Black Paint
SatinChrome SatinChrome BlackPlated
1) Other finishes and colors are available on special order.
Consult the factory for details.
(2) cULus Listed only.
3) 200°F (93°C) maximum.
° cULus listed "corrosion resistance" applies to SIN Numbers
RA1425 (Upright) and RA1414 (Pendent).
FM Approvals finish as 'Polyester coated" applies to SIN Number
RA1414 (Pendent).
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Li. Deflector Type
Temperature Rating
Sprinkler Finish
Escutcheon Type
Escutcheon Finish (where applicable)
Cover plate Model
Cover plate Thread size
Cover plate Temperature
Cover plate Adjustment
Cover plate Finish
Note: When Model F1FR 56 Recessed sprinklers are ordered, the
sprinklers and escutcheons are packaged separately.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Productsmanufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc. Recycled
G el- ,le (800) 431-1588 Sales Offices Paper
(800) 848-6051 Sales Fax Revision lines indicate updated or new data.
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address EU. Printed in U.S.A 12/09 P/N 99999/0300