HomeMy WebLinkAbout6221 METROPOLITAN ST; ; AS090159; Permit12/13/24, 4:00 PM AS090159 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS090159
6221
Job Address:
METROPOLITAN ST
Permit Type: SPRINK
Parcel No: 2132600100
Lot #: 0
Reference No.:
Status: ISSUED
Applied 12/29/2009
Approved: 12/29/2009
Issued: 12/29/2009
PC #: Inspector:
Project Title: DR. SHELHAMER T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant:
WESTERN FIRE PROTECTION
13630 DANIELSON
P0 WAY CA
858-513-4949
Owner:
BRESSI RANCH MEDICAL PLAZA L L C
DAVID DIRIENZO
1280 BISON AVE #139-609
NEWPORT BEACH CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
130 0 130 0
about:blank 1/1
QUICK RESPONSE
RECESSED PENDENT
QUICK RESPONSE
RECESSED
HORIZONTAL SIDEWALL
QUICK RESPONSE
A UTOMA TI C SPRINKLERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinkler is a low profile
yet durable design which utilizes a 3mm frangible glass ampule as
the thermosensitive element. This provides sprinkler operation
approximately six times faster than ordinary sprinklers. While the
Quick Response Sprinkler provides an aesthetically pleasing ap-
pearance, it can be installed wherever standard spray sprinklers
are specified but offers the additional feature of greatly increased
safety to life. Quick Response Sprinklers should be used advisedly
and under the direction of approving authorities having jurisdiction.
The heart of Globe's GL Series sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fluid. When heat is
absorbed, the liquid within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal pressure
within the ampule exceeds the strength of the glass causing the
glass to shatter. This results in water discharge which is distributed
in an approved pattern depending upon the deflector style used.
The sprinkler and escutcheon are not factory assembled.
Assembly is done in the field.
TECHNICAL DATA
See reverse side for Approvals and Specifications.
'Temperature Ratings - 135°F (57°C), 155°F (680C), 175°F
(79°C), 200°F (93°C), 286°F (141°C).
'Water Working Pressure Rating -175 psi (12 Bars).
Factory tested hydrostatically to 500 psi (34 Bars).
'Maximum low temperature glass bulb rating is -67°F (-55°C).
'Frame - bronze • Deflector - brass • Screw - brass
'Bulb seat - copper • Spring - nickel alloy ' Seal - teflon
Bulb - glass with alcohol based solution, 3mm size.
'Escutcheon Assembly - steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES COLOR CEILING TEMPERATURE
ORDINARY 35Ffl55°F . 5Gi68C ORANGE/RED
INTERMEDIATE 75°F!200 F 79 0/93 C ;YELLOWIGREEN. 150 F 66,1C .
HIGH 86F i141 C , BLUE 225°F 07Q
4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231
DECEMBER 2006 A-24 BULLETIN GL2801, REV. #5
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES
2.8 (39 metric) 112° NPT 2 1/4" (5.7 cm) Factory Bronze
4.2 (59 metric) 1/2' NPT 2 1/4" (5.7 cm) Satin Chrome 2
Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4' (5.7 cm) White Polyester 7.8 (111 metric) 112" NPT 2 1/4" (5.7 cm) Black Polyester
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16.
2 FINISHES AVAILABLE ON SPECIAL ORDER.
3C-UL LISTED CORROSION RESISTANT -
POLYESTER MUST BE SPECIFIED ON ORDER.
APPROVALS
STYLE SIN
MODEL
K
FACTOR
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
°°286°F
141°C cULus FM LPC CE NYC -DOB
MEAIOI-92-E
GL2801 2.8 X X X X X X - - - X GL4201 4.2 X X X X X X - - - X PENDENT GL5601 5.6 X X X X X X X X X X RECESSED
GL810I 7.8° X X X X X X X - - X GL8106 8.1 X X X X X X X X X X
GL2826 2.8 X X X X X X - - - X HORIZONTAL GL4226 4.2 X X X X X X - - - X SIDEWALL
- RECESSED § GL5626 5.6 X X X X X X - - - X GL8127 8.1 X X I X X X X - - - -
§ HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12° BELOW THE CEILING.
t5.6K ORIFICE, 7.8K ORIFICE AND 8.1K ORIFICE LISTED FOR ALL HAZARDS.
C °7.BKX1/2"NPT. ROSS ECTIONS X*286XF cULus LISTED ONLY.
r.:i
lt 7.7/,-77. DIX. 'Jr it. ........_..
7/8 MAX
t t 1/2 RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS.
ORDERING INFORMATION
SPECIFY
Quantity • Model Number • Style
Orifice • Thread Sizes ° Temperature
° Finishes desired
Quantity - Recessed Wrenches - P/N 325391 (1/2');
PIN 325401, Rev. F ti (IN
Quantity - Protective Caps - PIN 327109-CAP
(Friction Fit Recessed)
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its own
manufactured products found to be defective in material
or workmanship for a period of one year from date of
shipment.
For specific details of our warranty please refer to
Price List Terms and Conditions of Sale (Our Price List).
4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583 FAX989-846-9231
1-800-248-0278 www.globesprinkIer.com
DECEMBER 2006 PRINTEDU.S.A. BULLETIN GI-2801, REV. #5
TRANSMITTAL
DATE 12
TO LLt2 iI
(25 A\f
- -
ATTENTION P14LJ _44'
coci 19K - S Cr ).
CONTRACT NO.#
REMARKS 1S
DRAWING NO.
>-
>-
S
NUMBER OF DESCRIPTION Wm uni CD
COPIES -A °- C)
W LU CD
<o:: LU < C) U- > L o. < 0
NOTE RETURN 2,—COPIES OF DRAWINGS
MARKED WITH YOUR STAMP OF
ACCFPTANcE AND / OR COMMENTS SIGNED