Loading...
HomeMy WebLinkAbout6221 METROPOLITAN ST; ; AS090159; Permit12/13/24, 4:00 PM AS090159 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090159 6221 Job Address: METROPOLITAN ST Permit Type: SPRINK Parcel No: 2132600100 Lot #: 0 Reference No.: Status: ISSUED Applied 12/29/2009 Approved: 12/29/2009 Issued: 12/29/2009 PC #: Inspector: Project Title: DR. SHELHAMER T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON P0 WAY CA 858-513-4949 Owner: BRESSI RANCH MEDICAL PLAZA L L C DAVID DIRIENZO 1280 BISON AVE #139-609 NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 QUICK RESPONSE RECESSED PENDENT QUICK RESPONSE RECESSED HORIZONTAL SIDEWALL QUICK RESPONSE A UTOMA TI C SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing ap- pearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (57°C), 155°F (680C), 175°F (79°C), 200°F (93°C), 286°F (141°C). 'Water Working Pressure Rating -175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). 'Maximum low temperature glass bulb rating is -67°F (-55°C). 'Frame - bronze • Deflector - brass • Screw - brass 'Bulb seat - copper • Spring - nickel alloy ' Seal - teflon Bulb - glass with alcohol based solution, 3mm size. 'Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 35Ffl55°F . 5Gi68C ORANGE/RED INTERMEDIATE 75°F!200 F 79 0/93 C ;YELLOWIGREEN. 150 F 66,1C . HIGH 86F i141 C , BLUE 225°F 07Q 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 DECEMBER 2006 A-24 BULLETIN GL2801, REV. #5 QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 112° NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2' NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4' (5.7 cm) White Polyester 7.8 (111 metric) 112" NPT 2 1/4" (5.7 cm) Black Polyester 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3C-UL LISTED CORROSION RESISTANT - POLYESTER MUST BE SPECIFIED ON ORDER. APPROVALS STYLE SIN MODEL K FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C °°286°F 141°C cULus FM LPC CE NYC -DOB MEAIOI-92-E GL2801 2.8 X X X X X X - - - X GL4201 4.2 X X X X X X - - - X PENDENT GL5601 5.6 X X X X X X X X X X RECESSED GL810I 7.8° X X X X X X X - - X GL8106 8.1 X X X X X X X X X X GL2826 2.8 X X X X X X - - - X HORIZONTAL GL4226 4.2 X X X X X X - - - X SIDEWALL - RECESSED § GL5626 5.6 X X X X X X - - - X GL8127 8.1 X X I X X X X - - - - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12° BELOW THE CEILING. t5.6K ORIFICE, 7.8K ORIFICE AND 8.1K ORIFICE LISTED FOR ALL HAZARDS. C °7.BKX1/2"NPT. ROSS ECTIONS X*286XF cULus LISTED ONLY. r.:i lt 7.7/,-77. DIX. 'Jr it. ........_.. 7/8 MAX t t 1/2 RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS. ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes ° Temperature ° Finishes desired Quantity - Recessed Wrenches - P/N 325391 (1/2'); PIN 325401, Rev. F ti (IN Quantity - Protective Caps - PIN 327109-CAP (Friction Fit Recessed) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 1-800-248-0278 www.globesprinkIer.com DECEMBER 2006 PRINTEDU.S.A. BULLETIN GI-2801, REV. #5 TRANSMITTAL DATE 12 TO LLt2 iI (25 A\f - - ATTENTION P14LJ _44' coci 19K - S Cr ). CONTRACT NO.# REMARKS 1S DRAWING NO. >- >- S NUMBER OF DESCRIPTION Wm uni CD COPIES -A °- C) W LU CD <o:: LU < C) U- > L o. < 0 NOTE RETURN 2,—COPIES OF DRAWINGS MARKED WITH YOUR STAMP OF ACCFPTANcE AND / OR COMMENTS SIGNED