Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6221 METROPOLITAN ST; ; AS090077; Permit
12/13/24, 4:09 PM AS090077 Permit Data City of Carlsbad Sprinkler Permit 6221 Job Address: METROPOLITAN ST Permit Type: SPRINK Parcel No: 2132600100 Lot #: 0 Reference No.: Permit No: AS090077 Status: ISSUED Applied 7/15/2009 Approved: 7/16/2009 Issued: 7/16/2009 PC #: Inspector: Project Title: DR. BRIAN REAGAN, MD T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: BRESSI RANCH MEDICAL PLAZA L L C DAVID DIRIENZO 1280 BISON AVE #B9-609 NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 Department of Consumer Affairs Contractors State LiiéBoard Contractor's License Detail - License # 577621 & DISCLAIMER: A license status check provides Information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. > CSLB complaint disclosure is restricted by law (8&P..7.12.46). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. >> Per B&P 7071 .17, only construction related civil judgments reported to the CSLB are disclosed. >> Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Boards license database. License Number: 577621 Extract Date: 07/15/2009 COSCO FIRE PROTECTION INC Business Information: 501 W SOUTHERN AVENUE ORANGE, CA 92865 Business Phone Number: (714) 974-8770 Entity: Corporation Issue Date: 09/22/1989 Expire Date: 09/30/2009 License Status: This license is current and active. All information below should be reviewed. CLASS DESCRIPTION Classifications: C10 ELECTRICAL C16 FIRE PROTECTION CONTRACTOR CONTRACTORS BOND This license filed Contractors Bond number 1000615732 in the amount of $12,500 with the bonding company AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/01/2009 Contra.ctors Bonding HwtQy BOND OF QUALIFYING INDIVIDUAL Bonding: 1. This license filed Bond of Qualifying Individual number 1000777972 for BARRY GLEN FIELDING in the amount of $12,500 with the bonding company AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/23/2008 2. This license filed Bond of Qualifying Individual number 100047175 for JOHN DAVID STROHECKER in the amount of $12,500 with the bonding company AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 05/02/2008 This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number: A1CW92320901 Workers' Compensation: Effective Date: 06/01/2009 Expire Date: 06/01/2010 Workers Compensation History- Personnel listed on this license (current or disassociated) are listed on other licenses. Conditions of Use I Primacy Polic Copyright © 2009 State of California https ://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 07/15/2009 cosco• .. ••... ••... .•• '.'• I Fire Protection A301ooT~ San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 Slate License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date:7/1/2009 DR REAGAN MD 2221 METROPOLITAN ST #100 CARLSBAD, CA 92009 JOB # 0906-1696 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: ALE Los Angeles 0 San Francisco 0 Orange • Fresno 0 San Diego • Seattle I .COSCO 'I ..• •. SI •' Fire Protection San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16-5 77621 www.coscofire.com TABLE OF CONTENTS FIRE SPRINKLERS PIPE FITTINGS HANGERS August 4, 2006 Sprinkler 41 a MICROFAST® AND MicrofastHPO NIKJNG* QUICK RESPONSE 0 PENDENT SPRINKLERS PRODUCT NAME MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com PRODUCT DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Note: Units of measure in parentheses may be approximations. Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 06666B.) Sprinkler 41 b August 4, 2006 TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES I ....' Pop Err ure Tpera Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 F (68 °C) 100 F (38 °C) Red Intermediate 175 °F (79 C) 150 °F (65 °C) Yellow Intermediate 200 F (93 °C) 150 F (65 °C) Green High 286 ¶ (141 °C) 225 °F (107 C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinkler 066628), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® Corrosion-Resistant Coatings3: White Polyester (White Poly finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 41 C. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers: Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table 1 above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) Order Microfast® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200/93° = E, and 286°/141 = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W/B. **A '/2" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) August 4, 2006 Sprinkler 41 c ic rof as an ot P Rn Pen ent S mkl rs _ r Nominal Listings and Approvals3 Base Part Thread Size Overall Length Number1 SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT BSP U.S. I metric' Inches mm cULus4 I FM5 I NYC6 I VdS LPCBJ I Standard Orifice 06662B I VK302 1 1/2" 115 mm [ 5.6 I 80,6 1 2-1/4 I 58 JA1X, B1Y1A4X, B4Y1A1X, 81Y1 F2 I A4X IC4X, D4Y121 C4X, D4Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115,2 2-3/8 1 60 1 A3X, 83Y A2X, 132Y A3X, B3Y -- E412 -- 12104 VK352 3/4" 1 20 mm 1 8.0 115,2 2-1/4 1 58 1 -- -- -- F2 -- - -- 06765B VK352 1/2 115mm 1 8.0 115,2 1 2-3/8 1 60 JA3X,B3YJ A3X, 133Y I - -- -- -- _________ Small Orifice8 06718139 VK329 1/2" 15 mm 2.8 40,3 2-3/16 56 A3X, B3Y I A2X A3X, 133Y -- - -- 06720139 VK331 1/2" 115 mm 1 4.2 60,5 2-1/4 X,B3YJ A3X, B3Y -- -- -- 06932B VK331 - 1 10 mm 4.2 60,5 2-3/8 60 - -- -- F2 - F213 -- Maximum 250 PSI (17,2 bar) WWP ____________ Standard Orifice Base Part Thread Size Nominal Overall Length Listings and Approvals3 Number' SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT BSP U.S. metric2 Inches mm cULus4 FM NYC10 VdS LPCB (( 12282 VK317 1/2" 15mm 5.6 80,6 2-1/4 1 58 A3X, 133Y I -- A3X - - - -- Maximum 250 PSI (17,2 bar) WWP Small Orifice8 122909 1 VK342 I 1/2" 115 mm 1 2.8 1 40,3 I 2-3/16 I 56 IA3X, 133YI - I A3X -- Approved Temperature Ratings A- 135 "F(57 "C), 155 "F (68 "C), 175 "F (79 "C), Approved Escutcheons 200 "F (93 "C), and 286 "F (141"C) Approved Finishes x - Standard surface-mounted escutcheon B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), I - Brass, Chrome-Enloy®, White Poly Finish 7, or the Viking Microfast® Model F-i and 200 "F (93 "C) Black Poly Finish 7, and Black Teflon 7 Adjustable Escutcheon" C -155 "F(68 "C),.175 "F(79 "C), 200 "F(93 "C), 2 - Brass and ChromeEnloye V - Standard surface-mounted escutch- and 286 "F (141"C) 3 - Brass, Chrome-Enloy®, White Polyester7, eon or the Viking Microfasta Model D - 155 "F (68 °C), 175 "F (79 "C), and 200 "F Black Polyester 7. and Black Teflon 7 F-i Adjustable Escutcheon" or re- (93 "C) 4 - Brass, Chrome-Enloy®, White Poly Finish, cessed with the Viking Micro- E - 155 "F (68 °C), 175 "F (79 "C), and 286 "F and Black Poly Finish matic® Model E-1 or E-2 Recessed (141-C) Escutcheon F - 155 "F (68 "C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. ' Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA cULus Listed as corrosion resistant. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice is bushed. 10Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. "The Viking Microfast5 Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. 14, MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats. ""A 1/2" ratchet is required (not available from Viking). Figure 2: Wrench 12144W/B for Installing Coated and/or and Recessed Pendent Sprinklers Sprinkler 41 d August 4, 2006 ., ,. 19"M cULus Listing Requirements: Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aonroval Requirements: Quick Response Pendent Sprinklers are FM Approved as indicated in the Approval Chart for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, min1n6rh and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Ii fl:::..JF Wrench 12144W/B** for installing coated and/or recessed sprinklers with protective caps. -------------- August 4, 2006 Sprinkler 41 e Ceiling Opening Size: 2-5/16° (59 mm) Minimum, 2-1/8" - 2-1/2"(64 mm) Maximum. (54 mm) (15mIr NPT 1-3/4" (44,5 mm) Pendent Sprinkler 06662B 1-3/4" (44,5 mm) i2 — i Pendent Sprinkler 06662B Installed with a Standard 1/8" (3,1 mm) Surface-Mounted Escutcheon FMin(M 3 1/2" W " (50,8 mm) 1 mm) Maximum inum 2 Pendent Sprinkler 06662B Installed with the Microfast® Model F-i Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: I 2-5/16" (59 mm) Minimum, I 2-1/8' _2-1/8" (54 mm) 2-1/2" (64 mm) Maximum. (54 mm) 1-3/4" 1-1/8" (28,6 mm) Minimum (44,5 mm) Maximum I 2 T 2' 1-1/8' (28,6 mm) (50,8 mm) Minimum Pendent Sprinkler 06662B Maximum Installed with the Micromatic® Pendent Sprinkler 066626 Model E-1 Recessed Escutcheon Installed with the Micromatic® Model E-2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons 0 SCHEDULE- 10/40 Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch- 10 (1'/4"- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. r! [0 Specifications1 NPS Nominal I.D. WI. Wt. (H20 Filled) Pc WI/Lift (21') WI/Lift (24') WI/lift (251) In; mm In; mm Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 l'/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1½' 1.610 2.720 3.61 44 2,513. 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2' 2.469 5.790 7.86 19 2,310 21640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 t'iSpecifications NPS Nominal I.D. Wt. WI. (11120 Filled) Pc WI/Lift (21') WI/lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1¼' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1½' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2- 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2' 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 - Listed Approved Listed Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American FV Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test 16100 S. Lathrop' Harvey, IL 60426 Customer Service: tqca/F/ow Control ( II'.I 11350 Norcom Rd. -Philadelphia, PA 19154 (800) 882-5543 TUBE &CONDUIT 2525 N. 27th Ave.. Phoenix, AZ 85009 Fax 708-339-1806 S5-3 VICTAULIC IS AN ISO 0001 CERTIFIED COMPANY Styles 920 and 920N Mechanical-T® Bolted Branch Outlets PRODUCT DESCRIPTION Victaulic Mechanical-T4' Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. own JkLlk 0 Styles 920 and 920N All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or polybutylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. - Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Style 920 Cross See Victaulic publication 10.01 for details. See c/ian' on page 4 for presseire ratings. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-395, grade 65-45-15. and ASTM A-536, grade 65-45-12, with orange enamel coating. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to +110°C), Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +1 5OoF (+66°C) or for hot dry air over +140°F (+60°C). *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: (Styles 920 and 920N) Heat treated carbon steel zinc plated to ASTM B-633, track-head conforming to physical properties of ASTM A-183 minimum tensile 110,000 psi (758340 kPa). S REGISTERED TRADEMARK OF VICTAULIC - © COPYRIGHT 2003 VICTAUUC - PRINTED IN U.S.A. . 1480 REV F Victaulic Company ol America ' Phone: 1-800-PlcK-vlc(1-800.]42-5842)• Fax: 610-250-8817• e-mail:pickvic@niclaulic.com VICEOUIIC company of canada• Phone: 905-884-7444' Fax: 905-884-9774 e-mail: viCcanada@nictaulic.com Victaulic Europe. Phone:32-9-381-1500' ran: 32-9-380-4438' e-mail: viceuro@viclauliC.be Victaulic America latina' Phone: 610-559-3300' Fan: 610-559-3608' e-mail: vical@victaulic.com -ictnuli ViClaIIliC Asia Paciflc•. Phone: 65-6235-3035' Fax: 65-6235-0535' e-mail: nicap@xiclaulic.com DIMENSIONS Y Z Styles 920 and 920N wlGrooved Outlet Styles 920 and 920N w/Female Threaded Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. ', Those new size Style - NW 920N products require a HOLESlZE different hole size than the Style 920 it replaces, for proper installation Use caution to assure the proper size hole is prepared for the spcci8c size and style used. Failure to use the proper hole SIZE Could result in joint leakage and property damage. Max. Dimensions - Inches/millimeters Aprx. SIZE Work. Wgt. Each Hole Fern. Run X Branch Press. Dia. Thd. Grv. LbsAg Nominal Inches Style PSI +0.13 V V Fern. mm No. We 4.00 1 # W V Z Thd. Grv. 2 X 1/2 (a) 920N 500 1.50 2.00 2.53 - 1.63 4.91 2.50 3.1 - 50 X 15 3450 38.1 51 64 - 41 125 64 1,5 - X 3/4 (a) 920N 500 1.50 1.97 2.53 - 1.63 4.91 2.75 3.1 - X 20 3450 38,1 50 64 - 41 125 70 1,5 - X 1(a) 920N 500 1.50 1.81 2.53 - 1.63 4.91 2.75 3.0 - )( 25 3450 38,1 46 64 - 41 125 70 1.4 - X 1'/4 (8) t 920N 500 1.75 2.04 2.75 3.00 1.63 4.91 3.00 3.5 3.2 X 32 3450 44,5 52 70 76 41 125 76 1,7 1.5 X 11/2 (a) t 920N 500 1.75 2.03 2.75 3.12 1.63 4.91 3.25 3.6 3.2 X 40 3450 44,5 52 70 79 41 125 83 1,7 1,5 21/2 X 1/2 (8) 920N 500 1.50 2.21 2.74 - 1.82 5.14 2.75 3.0 - 65 5 15 3450 38,1 56 70 .. 46 131 70 1,4 - X 3/4 (a) 920N 500 1.50 2.18 2.74 - 1.82 5.14 2.75 3.0 - X 20 3450 38.1 55 70 - 46 131 70 1,4 - X 1 (a) 920N 500 1.50 206 2.74 - 1.82 514 2.75 19 - X 25 3450 38,1 52 70 - 46 131 70 1.4 - 11/4 t(a) 0N 500 2.29 302 54 300 30 3.2 X 32 3450 . 47.5 58 76 83 46 131 76 1.7 1,5 X 11/2 t(8) 920N 500 2.00 2.27 3.00 3.25 1.82 5.14 3.25 3.6 3.3 X 40 3450 50,8 58 76 83 46 131 83 1,7 1,6 76,1 mm X /2 (a) 920 300 1.50 2.22 2.75 - 2.25 6.50 3.18 3.9 - X 15 2065 38,1 56 70 - 57 165 81 1.8 - X 3/4 (a) 920 300 1,50 2.19 2.75 - 2.25 6.50 3.18 3.9 - 5 20 2065 38,1 56 70 - 57 165 81 1,8 - X 1(a) 920 300 1.50 107 2.75 - 2.25 6.50 3.18 3.8 - 5 25 2065 38,1 53 70 - 57 165 81 13 - 1 Y, (a) t 920N3450 500 1.75 2.25 300 ioo 3.5 3.2 X 32 44,5 57 76 83 49 144 76 1.6 1.5 X 1/ (a) 920N 500 2.00 2.25 3.00 3.25 1.92 5.67 3.25 3.5 3.3 X 40 3450 50,8 57 76 83 49 144 1 83 1.6 1,5 3 X 1/2 (a) 920N 500 1.50 2.53 3.06 - 2.29 5.75 2.75 3.4 - 80 X 15 3450 38,1 64 78 - 58 146 70 1.6 - X 3/4 (a) 920N 500 1.50 2.50 3.06 - 2.29 5.75 2.75 3.4 - X 20 3450 38,1 64 78 - 58 146 70 1,6 - X 1 (a) 920N 500 1.50 2.37 3.06 - 2.29 5.75 2.75 3.3 - X 25 3450 38.1 60 78 - 58 146 70 1,6 - X 11/4 (a) 1' 920N3450 500 1.75:' 2.54 3.25 3.56 2.29 5.75 3.00 3.8 3.7 X 32(b) 65 83 90 58 146 76 1,8 1,8 X 11/2 (a) t 920N3450 500 2.00 2.77 3.50 356 2.29 5.75 3.25 4.1 3.8 5 40 (b) 50,8 70 89 90 58 146 83 1,9 1.8 2(a) 920N 0 300 2.74 300 4.6 X 50 3450 63,5 70 89 90 58 146 99 2.3 2,1 31/2 X 2 920N 500 2.50 - - 3.75 2.44 6.30 3.88 - 3.8 90 X 50 3450 63,5 - - 95 62 160 99 - 1.8 4 X l/ (a) 920N 500 1.50 3.03 3.56 - 2.69 6.69 2.75 3.7 - 100 X 15 3450 38.1 77 90 - 68 170 70 1,8 - X 3/4 (a) 920N 500 1.50 3.00 3.56 - 2.69 6.69 2.75 3,7 - X 20 3450 38,1 76 90 - 68 170 70 1,8 - X 1(a) 920N 500 1.50 288 3.56 - 2.69 6.69 2.75 3.6 - X 25 3450 38,1 73 90 - 68 170 70 1,8 - X 11/4 (a) t 920N 500 7 ,1.75'. 3.07 3.78 4.00 2.69 6.69 3.00 4.0 3.6 X 32 (b) 3450 '44 78 96 102 68 170 76 1,9 1.8 X 11/2 (a) t 920N 500 2.00 3.28 4.00 4.00 2.69 669 3.25 4.2 3.9 X 40 (b) 3450 50.8 83 102 102 68 170 83 2,0 1,9 X 2 (a) t 920N 500 2.50 124 4.00 4.00 2.69 6.69 3.88 5.0 4.6 X 50 3450 63.5 82 102 102 68 170 99 23 2,1 X 21/2 (a) t 920 500 2.75 3.06 4.00 4.00 2.69 7.25 4.63 5.8 5.0 X 65 3450 69,9 78 102 102 68 184 118 2,6 2.3 X 76,1 mm 920 500 2.75 - - 4.00 2.69 7.25 4.63 - 6.4 3450 69,9 - - 102 68 . , 184 118 - 2.9 X 3 (a) t 920 500 3.50 3.50 4.50 4.13 2.69 7.25 5.25 8.4 6A X 80 3450 88,9 89 114 105 68 :-. 184 133 3,8 2,9 108,0 mm X i1/ (a) 920N 500 1.75 3.06 3,78 - 2.63 7.25 3.13 5.0 - X 32 3450 44,5 78 96 - 67 184 80 2,3 - X 1 / (a) 0N 500 2.00 3.28 4.00 - 2.63 7.25 3.38 5.0 - 5 40 3450 1 50,8 83 102 - 67 184 86 2,3 - Table continued on page 3. See notes on page 3. Styles 920 and 920N Mechanical-I® Bolted Branch Outlets VF i y Z Styles 920 and 920N wlFemale Threaded Outlet Max. Dimensions - Inches/millimeters Aprx. SIZE Work. Wgt. Each Hole Fern. Run X Branch Press. Dia. Thd. Grv. LbsJkq Fern. Nominal Inches Style PSI +0.13 V V Actual mm No, kPa -0.00 T t 8 f W V 2 Thd. Gm 108,0 mm X 2 (a) 920N 500 2.50 3.24 4.00 - 2.63 7.25 4.00 5.6 - X 50 3450 63.5 82 102 - 67 184 102 2.5 - X 2/ (a) 920 500 2.75 3.06 4.00 - 2.63 7.25 4.41 5.6 - 5 65 3450 69,9 78 102 - 67 1 184 112 2,5 - X 3 (a) 920 500 3.50 - - 4.00 2.63 7.25 5.00 - 6.5 X 80 3450 88.9 -- -, 102 67 184 127 - 3,0 5 X 11/2 (a) t 920 500 2.00 4.06 4.75 475 3.25 8.38 3.75 7.4 7.6 125 5 40 3450 50,8 103 121 121 83 213 95 3.4 3.4 2(a) t 920 500 150 406 475 &Th 125 88 4.38 8 ao X 50 1 3450 63,5 103 121 121 83 213 111 3.7 3.6 X 21/2 (a) t 920 500 2.75 3.81 4.75 4.75 3.25 8.38 4.63 8.3 7.9 1< 65 3450 69,9 97 121 121 83 213 118 3,8 3,6 X 76,1 mm (a)(b) 920 500 2.75 3.81 4.75 - 3.25 8.38 38 - - 3450 69.9 97 121 - 83 213 137 - - X 3 (a) t 920 500 3.50 4.00 5.00 j 4.63 3.25 8.38 5.38 8.4 8.8 X 80 3450 1 88.9 102 127 118 83 213 137 3.8 4,0 139,7 mm X 11/2 t 920 500 2.00 4.06 4.75 - 3.25 8.38 3.75 7.4 - X 40 3450 50,8 103 121 - 83 213 95 3.4 - X 2 t 920 500 2.50 4.06 4.75 - 3.25 838 4.38 8.3 - X 50 3450 63,5 103 121 - 83 213 111 3.7 - X 76,1 mm (a)(b) 920 500 3.50 - - 4.63 325 838 5.38 - 88 3450 88,9 - - 118 83 213 137 - 4,0 3 920 500 3.50 - -4.63 -8.8 X 80 3450 88.9 - - 118 83 213 137 - 4,0, 6 X 1 1/1 920N 500 175, - - 5.13 3.79 9.13 3.25 - 4.8 150 X 32(b) 3450 '44,5. - - 130 96 232 83 - 2,2 X 11/2 (a) t 920N 500 2.00 4.40 5.13 5.13 3.79 9.13 3.25 5.4 5.1 X 40 (b) 3450 50,8 112 130 130 96 232 83 2.4 2.3 X 2 (a) I 920N 500 250 4.37 513 5,13 179 9.13 3.88 0 56 X 50 3450 63,5 111 130 130 96 232 99 23 2.5 X 21/2 (a) t 920 500 2.75 4.19 5.13 5.13 3.69 938 4.63 8.3 7.6 X 65 3450 69.0 106 130 130 94 238 118 3,8 3,4 X 76,1 mm (a)(b) 920 500 2.75 - - 5.21 3.69 938 5.38 - BA 3450 69.9 - - 132 94 238 137 - 3,8 X 3 (a) t 920 500 3.50 4.50 5.50 5.13 3.69 9.38 5.38 9.9 BA X 80 3450 88.9 114 140 130 94 238 137 4,5 3,8 X 4(a) t 920 500 X 100 3450 114,3 114 146 137 94 238 159 4.6 4,6 159,0 mm X 71/7 (a) 920N 500 2.00 4.41 5.13 - 3.63 9.25 3.38 7.8 - X 40 3450 50,8 112 130 - 92 235 86 3,5 - 2(a) 920N o 250 437 Th - 363 925 00 80 - X 50 3450 63,5 111 130 - 92 235 102 3,6. - X 21/2 (a) 920 500 2.75 4.56 5.50 - 3.63 9.25 4.75 8.6 - X 65 3450 69.9 116 140 - 92 235 121 3,9 - X 108,0 mm 920 3450 114,3 -. - 137 92 235 159 - 4.5 165,1 mm X 1'/2 (a) t 920 500 2.00 4.44 5.13 5.13 3.69 9.38 3.75 7.9 6.9 X 40 3450 50,8 1 113 130 130 94 238 95 3.6 3.1 X 2(a) 1 920 500 2.50 4.44 5.13 5,13 3.63 9.38 4.38 8.0 7.0 X 50 3450 63,5 113 130 130 92 238 111 3,6 3,2 X 2112 t 920 500 2.75 4,19 5,13 5.13 3.69 9.38 4.63 8.6 7.6 X 65 3450 69,9 106 130 130 94 238 118 3,9 3,4 920 500 2.75 4.08 5.13 5.21 3.69 9.38 5.38 8.6 7.6 X 76,1 mm (a)(b) 3450 69.9 104 130 132 94 238 137 3,9 3.4 X 3 (a) 1 920 500 3.50 4.50 5.50 5.13 3.69 938 5.38 10.2 84 5 80 3450 88,9 1 114 140 130 94 238 137 4,6 3,8 X 4 (a) T 920 500 4.50 4.50 5.75 5.38 3.63 9.38 6.25 10.5 8.4 5 100 3450 114.3 114 146 137 92 238 159 4.8 3,8 8 X 2 (a) 920 500 2.75 5.19 6.25 - 4.88 12.00 4.50 11.6 - 200 X 50 3450 69,9 132 159 - 124 305 114 5.3 X 2 /2 (a) 1 920 500 2.75 5.19 6.25 6.25 4.88 12.25 4,50 11.6 11.6 X 65 3450 69,9 132 159 ''159 124 311 114 53 53 X 76,1 mm (a)(b) 920 500 2.75 519 625 - 488 12130 5.38 - - 3450 69,9 132 159 ' .' 124 305 137 X 3(a) 1 920 500 3.50 550 650 6.25 4.88 12.00 5.38 12.6 11.6 5 80 3450 88,9 140 165 159 124 305 137 5,7 5,3 X 4(a) 1 920 500 4.50 5.31 6.75 6.38 4.88 12.00 6.25 15.3 12.5 X 100 3450 1143 135 171 162 124 305 159 6.9 5.7 See notes at left. DIMENSIONS filv Styles 920 and 920N wlGrooved Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. -' These new size Style NEW 920N products require a HOLE size different hole size than the Style 920 it replaces, for proper installation Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. NOTES Center of run to engaged pipe end, female threaded outlet only (Dimen- sions approximate). Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. # Female threaded outlets are avail- able to NPT and BSPT specifications. British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. For 76,1 mm threaded outlet, spec-ify 21/2' BSPT clearly on Order. Styles 920 and 920N Mechanical-T11 Bolted Branch Outlets FLOW DATA Exaggerated for Clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 900N and 929 Mechanical-T11 fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. OUTLET SIZE Equivalent Length Feet/meter of Pipe Nominal Actual Diameter Out. Die. Female InJmm InJmm Grooved Threaded 1/2 0.840 - 2.0 15 21,3 - 0,6 3/4 1.050 - 4.0 20 26,7 - 1,2 1 1.315 - 5.0 25 333 - 1,5 11/4 1.660 5.5 6.0 32 42.4 13 1,8 11/2 1.900 7.0 8.0 40 48,3 2,1 2.4 2 2.375 9.0 10.5 50 60,3 23 3,2 21/2 2.875 11.0 12,5 65 73,0 3,4 3,8 3 3.500 13.5 15.5 80 88.9 4,1 43 4 4.500 20.0 22.0 100 114.3 6,1 63 Cv Values Values for flow of water at +60F (+16CC) are shown in the table at right. Formulas for CV Values AP -Qf C17 Q = Where: Q = Flow (GPM) AP = Pressure Drop (PSI) Cv = Flow Coefficient Pipe Size Pipe Size Pipe Size Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Diameter Diameter Cv Diameter Diameter Cv Diameter Diameter Cv Inches/mm Inches/mm Values Inches/mm Inches/mm Values Inches/mm Inches/mm Values 1/2 0.840 17 1'/4 1.660 45 21/2 2.875 135 15 21.3 32 42,4 65 73.0 1.050 21 11/2 1.900 60 3.500 200 20 26,7 40 48,3 80 88.9 1 1.315 25 50 2 2.375 100 4 4.500 400 25 60,3 100 1143 APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressures Run Size PSi/kPa Actual Nominal Outside Diameter Diameter Pipe Inches/mm Inches/mm Schedule UL ULC FM 21/2 6 2.875 - 6.625 400 400 400 65-150 73,0-168,3 ' 10,40 2755 2755 2755 21/2 - 4 2.875 - 4.500 DF 300 300 300 65-100 73.0-114,3 2065 1 2065 1 2065 21/2 4 2.875 - 4.500 F 300 300 300 65-100 73,0-114,3 2065 2065 2065 1 IV fVIQ1b io LIS4CU11OVO0 cnoouie IV steei sprinKler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. -, DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 4 . -- .. Styles 920 and 920N Mechanical-I® Bolted Branch Outlets c®u$ LISTED Fig. 25 - Surge Restrainer Size Range — One size fits 3/4" thru 2' pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters' Laboratories Listed galy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951,737.0330 I CUSTOMER SERVICE • 800.786.5266 www.folco.com Fig. 69 - Beam Clamp Retaining Strap Size Range - 3/8 thru 7/8 rod by 4" thru 16' length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1". Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 1/2 9/16 Specify Specify 2 5/8 11/16 3/4 13/16 Specify Specify 3 3/8 -7/8 Specify Specify * Longer lengths are available, consult factory. -- Component of State of California OSHPD Approved c@ us Seismic Restraints System OEFICEJMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com FIG. 98 I to Length 11116, Dimensions od Max. Rec. Load Lbs. For Service Temp 3/8 730 112 N*44hh.,2160 1350 5/8 U U Component of State of California OSHPD Approved Seismic Restraints System 98 - Rod Stiffener Fl . B - Rod Stiffener w/Break-off Bolt Head Size Rand116L Secures 3/8 thru 7/8 hanger rod Material - Ca Steel Function - Secur annel to hanger rod for vertical seismic bracing. Approvals - Include our Seismic Restraints Catalog approved by the State of California e of Statewide Health Planning and Development (OSHPD). For'11111kional load, spacing and placement information relating to OSHPD p ts, please refer to the TOLCO Seismic Restraint Systems Guidelin Finish - Electro Galvanized Note - Available in HDG finish or Stainless I materials. Order By - Figure number Fig. 99 — All Thread Rou Size Range - Secures 3/8 thr rod in 1 increments Material - Carbon Stee Maximum Temperat - 750°F Finish - Plain Note - Ava in Electro-Galvanized and HDG fini Stainless Steel materials. Orde - Figure number, rod diameter, rod le and finish Fig. 100- All Thread Rod Full Length Size Range - Secures 3/8 thru 11h rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wtf100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 : 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1½ 13800 510 U OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951,737.5599 • FAX: 951.737.0330 - CUSTOMER SERVICE 800.786.5265 - www.toko.com Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8 pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thru 2) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2 ' thru 8) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4' thru 8). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. I Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/a 400 11 3/4 3/8 8mm or10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3% 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/81 10mm 7% 51/4 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/s 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE '800786.5266 - . - vww.tolco.com