Loading...
HomeMy WebLinkAbout3115 MELROSE DR; 110; AS080070; Permit12/13/24, 4:16 PM AS080070 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3115 MELROSE DR Permit Type: SPRINK Parcel No: 2218801300 Lot #: 0 Reference No.: Permit No: AS080070 Status: ISSUED Applied 5/6/2008 Approved: 5/20/2008 Issued: 5/20/2008 PC #: Inspector: Project Title: OPUS POINT- SUITE 110 TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: SIMPLEX GRINNELL OPUS WEST CORP 3568 RUFFIN ROAD 2555 E CAMELBACK RD #800 SAN DIEGO CA PHOENIX AZ 858-633-9100 rFees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 tqC0 Fire & Building liProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB - 2.8, 42, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT)or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 314'NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I Page 2 of 10 ESCUTCHEON 7/16 (11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2 MAKE-IN NPT 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) TFPI7I STYLE 10 or 20 RECESSED * ESCUTCHEON SSU DEFLECTOR 6 7/16" 1 5 (11,1 mm) I NOMINAL I _ MAKE-IN 2 2-3/16" WRENCH FLATS (55,6 mm) 1/2" NPT SSP DEFLECTOR* h — 2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2" MAKE-IN NPT 2-3/16" \i (55,6 mm) 1-1/2" (38,1 mm) . STYLE 10 or 20 RECESSED 51* ESCUTCHEON DEFLECTOR 6* 7/16" I 5 (11,1 mm) NOMINAL MAKE-IN I 2-3/16" WRENCH FLATS _______ 55,6 mm) ______ 1 1/2" NPT SSP DEFLECTOR - 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 1/2" (12,7 mm) NOMINAL MAKE-IN I 2-1/4" (57,2 mm) CROSS SECTION TFPI7I ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2 NOMINAL SURFACE NPT MAKE-IN 2-3/16 (55,6 mm) I (38,1 mm) Page 3 of 10 STYLE 10 or 20 RECESSED SJ___ ESCUTCHEON DEFLECTOR 6* 7/16" 1 5 (1111,11 mm) NOMINAL LI _____ MAKE-IN 2-3/16" / WRENCH FLATS ________ 55,6 mm) ______ 1 3 1/2" NPT SSP DEFLECTOR * j--- 2-7/8" (73,0 mm) DIA PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE 3/4,,MAKE-IN NPT 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR WRENCH FLATS SSP DEFLECTOR ---- 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 1/2" NPT Ss1J * DEFLECTOR 7/16(11,1 mm) NOMINAL MAKE-IN 'I cl-I S .4- Page 4 of 10 TFPI7I _r__ 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) = .-.-... SsP* DEFLECTOR PENDENT 1 - Frame 3-Sealing 4- Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psil/2 (40,3 LPM/barl'2) K = 4.2 GPM/p5i1/2 (60,5 LPM/bari'2) K = 5.6 GPM/ps1112 (80,6 LPM/barl'2) K = 8.0 GPM/p51112 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflonj- Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL BRASS I WHITE LIQUID FCHROME LATED JPOLYESTER 2.8 1/2 PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F/57°C Orange 123,5 155F/68°C Red 175F/79C Yellow 200°F/93C Green 286°F/141C Blue NPT RECESSED (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 5 PENDENT 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231) Figure 7 135°F/57°C Orange 155F/68C Red 175°FI79C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (1Y2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155F/68°C Red 175F/79C Yellow 200F/93C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57°C Orange 155°F168°C Red 175F/79C Yellow 200F/93C Green RECESSED PENDENT (TY2231)** Figure 9 135F/57C Orange 155°F/68°C Red 175°F/79C Yellow 200F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LEAD LIQUID BRASS PLATED IPOLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) and 12,3,4,5,6,7 1,23,5 155F/68°C Red 175F/79°C Yellow UPRIGHT 200F/93°C Green 5.6 (TY3131) 28&F/141°C Blue 1/2 NPT 135°F/57C Orange RECESSED PENDENT (TY3231)* 1,2,4,5 N/A 155°F/68C Red 175F/79C Yellow Figure 10 200°F/93°C Green 135°F/57C Orange RECESSED PENDENT (TY3231) 12,3,4,5 N/A 155°F168°C Red 175F/79C Yellow Figure 11 200F/93C Green 135F/57°C Orange PENDENT (TY4231) and UPRIGHT 1, 2,3,4,5,6,7 1,2,5 155F/68C Red 175F/79°C Yellow 200°F/93C Green 8.0 3/4" '4131) 286°F/141°C Blue NPT 135F/57°C Green RECESSED PENDENT (TY4231)* 1,2,4, 5 N/A 155°F/68°C Orange 175F/79C Red Figure 12 200°F/93C Yellow 135°F/57°C Orange RECESSED PENDENT (TY4231)** 1,2,3,4,5 N/A 155°F/68C Red 175°F/79°C Yellow Figure 13 200°F/93°C Green 135°F/57°C Orange 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT 1,2,4,5,6 1, 2, 5 155°F/68C Red 175°F/79C Yellow 200°F/93°C Green (TY4831) 286°F/141C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 56 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT(TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57C to 3/32 inch (2,4 mm) for the 286F/141C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-7/8" DIA. (73,0 mm) 5/8±1/4" I 3/4" (19,1 mm) - (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) SPRINKLER PLATE FACE OF L_57'2 mm) MOUNTING FITTING 1/8" mm) \%< MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF ' MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) I / MOUNTING SURFACE/ I CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) SPRINKLEqR PLATE FACE OF mm) MOUNTING FITTING 1/8 SURFACE (32 mm) MOUNTIN 4 CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73,0 mm) 1/2"(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLEqR PLATE FITTING 1/8" (32 mm) MOUNTIN SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFPI7I - 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (159±6,4 mm) - 2-1/4' DIA. I 1/4" (6,4 mm) I FACE OF SPRINKLER - _57,2 mm) MOUNTING PLATE I FITTING 1/8" (3.2mJ MOUNTING t I SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF (57,2 mm) -H I I MOUNTING PLATE SPRINKLER FITTING ________ 1/8" _ ____________ (3,2 mm) __ _ _j 1 MOUNTING SURFACE ________ CLOSURE SERIES 1-5/16" (33,3 mmi T'(FRB 13/16(20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) [(12,7±3,2 mm) - 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF SPRINKLER - 57,2 mm) MOUNTING PLATE FITTING 1/8" (32mm) 1 _ _ 'hit MOUNTING SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TYfRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE FITTING I (2mm I f \ - MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 TFPI7I PIN 57-XXX-X-XXX I L MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) 1Y1231 340 4.2K UPRIGHT (1/2"NPT) 1Y2131 341 4.2K PENDENT (1/2"NPT) 1Y2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4"NPT) 1Y4131 391 8.0K PENDENT (3/4"NPT) 1Y4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0KPENDENT(1/2"NPT) TY4931* I I - I SPRINKLER L 135 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED I 155 175 200 286 TEMPERATUF RATING ___ 155°F/68°C 175°F/79°C 2000F/93*C 286*F/141*C * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship, when paid for and properly installedand maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a oar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin-ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446