HomeMy WebLinkAbout3115 MELROSE DR; ; AS130203; Permit12/13/24, 4:17 PM AS 130203 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS130203 Job Address: 3115 MELROSE DR Status: ISSUED Permit Type: SPRINK Applied 11/13/2013 Parcel No: 2218801300 Approved: 11/22/2013 Lot #: 0 Reference No.: Issued: 11/22/2013 PC #: Inspector: Project Title: VALUATION VISION TI—INSTALLATION OF NEW FIRE SPRINKLER HEADS IN PREPARATION FOR NEW WALLS. FIRE SPRINKLERS WILL BE SUPPLIED FORM EXISTING FIRE SPRINKLER PIPING ABOVE SUSPENDED CEILING. Applicant: A& D FIRE SPRINKLERS 11465 WOODSIDE AV SANTEE, CA 619-448-1962 Owner: H R MELROSE LLC 11990 SAN VICENTE BLVD #200 LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 268 0 268 0 about:blank 1/1 • FIRE SPRINKLERS INC. VALUATION VISION 3115 MELROSE DR SUITE 120 CARLSBAD, CA FIRE SPRINKLER SUBMITTAL MANUFACTURER'S DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. AS13020014 O FIRE SPRINKLER SUBMITTAL TABLE OF CONTENTS FIRE SPRINKLERS. PIPE. HANGERS. S 0 1).- FIRE SPRINKLERS 0 [I QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL Oman um No FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT* PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. oTemperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) oWater Working Pressure Rating - 175 psi (12 Bars) 0 Factory tested hydrostatically to 500 psi (34 Bars) 0 Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass o Screw - brass Lodgement Wire - stainless steel Bulb seat - copper 0 Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLA5SII-IUAIIUN ana UULUK uuuiivu AVAILABLE SPRINKLER N. F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CEILING TEMPERATURE ORDINARY 136'F 1°F 57 C168 C ORANGE/RED 100 F 38°C INTERMEDIATE 17 F F1200 791C/931C YELLOW/GREEN 150 6 c HIGH 286F 141°C BLUE 25°F 107°C 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TOMA TI C SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL I DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safetyto life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA 0See reverse side for Approvals and Specifications. oTemperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) 0 Water Working Pressure Rating - 175 psi (12 Bars) 0 Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) 0Frame - bronze o Deflector - brass o Screw - brass Bulb seat - copper o Spring - nickel alloy • Seal - teflon Lodgement Wire - stainless steel Bulb - glass with alcohol based solution, 3mm size Escutcheon Assembly - steel QUICK RESPONSE RECESSED PENDENT QUICK RESPONSE RECESSED HORIZONTAL SIDEWALL QUICK RESPONSE LPC!CE RECESSED HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CEILING TEMPERATURE ORDINARY 135?Fi55°F 57°C/68°C ORANGE/RED 38"C INTERMEDIATE 174F -/200'F 39 GI9 C YELLOW/GREEN 15O 66 0 HIGH 286 F 141C BLUE L 225F 107 C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 JULY 2012 A-24 BULLETIN GI-2801, REV.#10 QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze 4.2 (59 metric) 1/2 NPT 2 1/4 (5.7cm) Chrome 5.6 (80 metric) 1/2 NPT 2 1/4 (5.7cm) White Polyester 7.8 (111 metric) 1/2 NPT 2 1/4 (5.7cm) Black Polyester 2,3 8.1 (116 metric) 3/4' NPT 2 7/16" (6.2cm) METRIC CONVERSIONS ARE APPROXIMATE. I HORIZONTAL SIDEWALL IS 2 9/16. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS SIN K 135°F 155°F 175°F 200°F 286°F cULus FM LPC CE NYC - DOB STYLE MODEL FACTOR HAZARD 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X - - - X GL4215 4.2 LH X X X X X X - - - x UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 7.8* LH/OH X X X X X X - - - X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X - - - X GL4201 4.2 LH X X X X X X - - - X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8° LH/OH X X X X X X X - - X GL8106 8.1 LH/OH X X X X X I X X X X X VERTICAL GL5632 5.6 LH X X X X X X X - - - SIDE WALLt GL8133 8.1 LH X X X X X X - - - - GL2826 § 2.8 LH X X X X X X - - - x GL4226 § 4.2 LH X X X X X X - - - X HORIZONTAL GL5626 § 5.6 LH/OH X X X X X X X - - X SIDEWALL GI-5627a 5.6 LH/OH X X X X X - - X X - GL8127 § 8.1 LH/OH X X X X X I X - - - - CONVENTIONAL GL5624 5.6 LH/OH X X X X X - - X X - (OLD STYLE) GL8125 8.1 LH IOH X X X X X - - X X - 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4 TO 6" BELOW THE CEILING. DINSTALL IN ACCORDANCE TO 6S5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6 MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9 MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °112' NPT n ORDERING INFORMATION SPECIFY 'Quantity • Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired 'Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) glio mo a FIRE SPRINKLER CORPORATION JUNE2012 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com BULLETIN GI-5615, REV. #9 989-846-4583 1-800-248-0278 PRINTED U.S.A. QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES O RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES 2.8 (39metric) 1/2' NPT 2 1/4' (5.7cm) Factory Bronze 4.2 (59metr1c) 1/2" NPT 2 1/4' (5.7cm) Chrome 5.6 (80 metric) 1/2' NPT 2 1/4' (5.7cm) White Polyester3 7.8 (111 metric) 1/2' NPT 2 1/4' (5.7cm) Black Polyester23 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) METRIC CONVERSIONS ARE APPROXIMATE 1 HORIZONTAL SIDEWALL IS 2 9/16. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD' 135°F 155°F 175°F 200°F **286F cULus FM LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEAIOI-92-E GL2801 2.8 LH X X X X X X - - - X GL4201 4.2 LH X X X X X X - - - X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X RECESSED GL8101 7.8° LH/OH X X X X X X X - - X GL8106 8.1 LH/OH X X X X X X X X X X GL2826 2.8 LH X X X X X X - X HORIZONTAL GL4226fl 4.2 LH X X X X X X - - - X SIDEWALL GL5626 5.6 LH/OH X X X X X X - - - X RECESSED GL5627a 5.6 LH/OH X X X X X - - X X - GL8127 8.1 LH/OH X X X X X X I - 11 1SPNKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. MIN. MP.X. PENDENT ORDERING INFORMATION SPECIFY Quantity . Model Number . Style Orifice • Thread Sizes • Temperature • Finishes desired Quantity - Recessed Wrenches - P/N 325391 (1/2"); PIN 325401 (3/4") Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) 014MM FIRE SPRINKLER CORPORATION JULY 2012 **2860F cULus LISTED ONLY BRASS FINISH ONLY OR ORDINARY HAZARD LH: LIGHT HAZARD *1/2 NPT LPCICE HORIZONTAL SIDEWALL GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12' BELOW THE CEILING. U INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tt 1/2" RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS CROSS SECTIONS HORIZONTAL SIDEWALL 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com PRINTED U.S.A BULLETIN GL2801, REV.#10 ci (.)•• •fl FIRE SPRINKLER CORPORATION ,,THE INCH" QUICK RESPONSE A U TO MA TIC SPRINKLERS MODEL GL5606 ONE INCH ADJUSTABLE DESCRIPTION AND OPERATION CONCEALED PENDENT The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2%" diameter ceiling plate colorfinished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burstallowing the deflectorto drop down and distributewater in an approved pattern to extinguish or control the fire. TECHNICAL DATA See reverse side for Approvals and Specifications. oTemperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 35/16" diameter plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate oWater Working Pressure Rating -175 psi (12 Bars) 0 low temperature glass bulb rating is -67°F (-55°C) Factory tested hydrostatically to 500 psi (34 Bars) 0 Frame - bronze • Deflector - brass • Screw - brass Bulb seat - brass o Spring - nickel alloy • Seal - teflon 23/4" diameter plate Bulb - glass with alcohol based solution, 3mm size QUICK RESPONSE Drop Pin - stainless steel WHITE ADJUSTABLE 0 Cover Plate - brass CONCEALED PENDENT 0 Upper Escutcheon Assembly - plated steel NOTE: Globe's wrench PIN 332765 must be used to install this sprinkler. SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE BULB N.F.P.A. MAXIMUM CEILING CLASSIFICATION SIF SPRINKLER TEMPERATURES COLOR TEMPERATURE ORDINARY 135TI15°F 5. 57°C/68°C. ORANGE/RED 00'F. 3851C I INTERMEDIATE 175P1200F 79°C/93°C YELLOW/GREEN 150 F .- 666C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989) 846-4583 • FAX 989-846-9231 MAY 2012 A-38 BULLETIN GL5606 REV#6 QUICK RESPONSE A UTOMA TIC SPRINKLERS MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES Bright Chrome White Painted 5.6 (80 metric) 1/2 NPT 2 1/2" (6.4 cm) Bright Brass' Satin Chrome' Other Painted Finishes' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. APPROVALS **1350F (57°C) 155°F (68°C) **1550F (68°C) 175°F (79°C) 200°F (93°C) NYC-DOB STYLE SIN K with plate with plate with plate with plate with plate cULus *FM MEA MODEL FACTOR 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) 101-92-E Adjustable Concealed GL5606 5.6 X X X X X X X X Pendent *FM APPROVED AS STANDARD RESPONSE **NO FM APPROVALS CROSS SECTIONS H- 2 1/4 DIR. MIN. I HOLE IN CEILING NA. 1, x l/2 REDUCER 2 3f4 MAX. 17/8" MIN. DROP PIN SUPPORT SHELL- CEILING COVER OPTIONAL COVER PLATE SIZE WHITE 135°F PART # WHITE 155°F PART # CHROME 135°F PART # CHROME 155°F PART # 23/4" 332726 332731 332724 332729 35/16" 332706 332711 332704 332709 522PM CEIUE ORDERING INFORMATION SPECIFY Quantity . Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Adjustable Concealed Wrenches - P/N 332765 gE,4 , D s, FIRE SPRINKLER CORPORATION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com MAY 2012 PRINTED U.S.A. BULLETIN GL5606 REV#6 QUICK RESPONSE A U TO MA TI C SPRINKLERS GL SERIES UPRIGHT o PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design QUICK RESPONSE requirements. Quick Response Sprinklers should be used advisedly UPRIGHT CONVENTIONAL and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results . in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL *See reverse side for Approvals and Specifications. SIDEWALL oTemperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) oWater Working Pressure Rating - 175 psi (12 Bars) oFactory tested hydrostatically to 500 psi (34 Bars) oMaximum low temperature glass bulb rating is -67°F (-55°C) 0 Frame - bronze • Deflector - brass • Screw - brass 0 Bulb seat - copper o Spring - nickel alloy o Seal - teflon QUICK RESPONSE oBulb - glass with alcohol based solution, 3mm size HORIZONTAL SIDEWALL o SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CEILING TEMPERATURE ORDINARY 1350F/155°F 570C/680C ORANGE/RED 100°F 38°C INTERMEDIATE 1750F/200°F 790C/930C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4077 Al RPARK DRIVE, STANDISH, MICHIGAN 48658 989-8464583 9 FAX989-846-9231 MAY 2011 A-20 BULLETIN GL5615, REV. #7 I I QUICK RESPONSE A U TO MA TI C SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL e CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2 NPT 2 1/4 (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2 NPT 2 1/4' (5.7 cm) Bright Chrome Satin Chrome 2 5.6 (80 metric) 1/2' NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4' (5.7 cm) Black Polyester 2.3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2.3 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. hUIILON IP,L IUVVLL 1,)2W10 . 2FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F. M. LPC CE NYC - DOB MEA MODEL FACTOR 57°C 68°C 79°C 93°C 141°C 101-92-E GL2815 2.8 X X X X X X -- -- --- X GL4215 4.2 X X X X X X -- - --- X UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8* X X X X X X -- - -- X GL8118 8.1 X X X X X X X X X X GL2801 2.8 X X X X X X - -- X GL4201 4.2 X X X X X X --- -- --- X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8* X X X X X X X - --- X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X -- --- -- SIDEWALLt GL8133 8.1 X X X X X X - -- -- -- GL2826 2.8 X X X X X X -- -- --- X HORIZONTAL GL4226 4.2 X X X X X X -- -- -- X SIDEWALL § GL5626 5.6 X X X X X X X - --- X GL8127 8.1 X X X X CONVENTIONAL GL5624 5.6 X X X X X -- --- X X -- (OLD STYLE) GL8125 8.1 X X X X X -- -- X X - S ORDERING INFORMATION SPECIFY Quantity • Model Number . Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) al4mm FIRE SPRINKLER CORPORATION MAY2011 *1/2 NPT t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-8464583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #7 From: 01/13/2014 17:51 #129 P.005/007 n Contractors Material and Test Certificate for Aboveground Piping PROCEDURE Upon completbn of work, Inspection and tests shall be made by the contractor's representative and witnessed by an owners representative. AD dsfds shall be corrected and system left In service before contractors personnel finally leave the Job. A certificate shalt be filled out and signed by both representatives. Copies shalt be prepared for approving authorities, owners, and contractor. It Is understood the owner's representative's signature In no way prejudiceS ay claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Propertynarne V;o IDate Property address 35 /20 Accepted by approving authorities (names) O'cC..i5 ã Address Plans Installation conform to accepted plans )s E No Equipment used Is approved f Yes 0 No if no, explain deviations Has person In charge of fire equipment been Instructed as [i'as ED No to location of control valves and care and maintenance of this new equipment? If no, explain? Instructions Have copies of the blowIng been left on the premises? 0 Yes Cl No System components Instructions 0 Yes 0 No Care and maintenance Instructions 0 Yes 0 No NFPA2S C) v 0 No Location of system Supplies buildings Year of orifice Temperature Make Model manufacture size Quantity rating GLbL 0.2. SL.til.. 2oi t/" __ ISIS, Spriniders i t,tS I Pipe and Type of pipe 30 fittings Type of fittings %>,c.ê& 4r4.cJ Maximum time to operate Alarm valve Or flow Alarm device through test connection Type Make 'Model Minutes Seconds iniôator Dry valve Q.O.D, Make Model Serial no. Make Model -Serial no. Dry pipe operating test - - Timetop through test connection'l Water pressure Air pressure Trip point air pressure Time water reached tastoutlett Alarm operated properly - Minutes Seconds pal psi psi Minutes Seconds Yes I No V11 out Q________ If no, explain FIRF PRflTIrTlfli\f lMr From 01/13/2014 17:51 #129 P.006/007 Operation S [J Pneumatic E] Electric D Hydraulics Piping supervised ED Yes [] No Detecting media supervIsed D Yes No Does valve operate from the manual trip, remote, or both EJ Yea D No control stations? Deluge and preactlon valves Is there an accessible facility in each circuit for testing? 1:JYas C3 No if no, explain Make Model Does each circuit operate supervision loss alarm? Does each circuit operate valve release? Maximum time to operate release Yes No Yes No Minutes Seconds Pressure Location and floor Make and model Setting Static pressure Residual pressure (flowing) Flow rate valve test reducing inlet (psi) Outlet (psi) J Inlet (psi) Outlet (psi) Flow (gpm) Test description Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4bsr) above static pressure in excess of 150 psi (10.2 bat) for 2 hours. Differential thy-pipe valve clappers strati be left open during the list to prevent damage. All aboveground piping leakage shall be stopped. Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1½ psi (0.1 bar) In 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1½ psi (0.1 bar) In 24 hours. AN piping hydrostatically lasted at -psi (_ bar) for _. hours If no, state reason Dry piping pneumatically tested D Yes El No Equipment operates properly 0 Yes j) No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brle, or other corrosive chemicals were not used for testing systems or stopping leaks? Elves No Tests Drain I test Reading of gauge located near water supply test connor1• psi (_ bar) Residual pressure with valve in test I connection open wide_ psi (_ bat) Underground mains and lead In connections to system risers flushed betori connection made to sprinkler piping Verified by copy of the U Form No. 858 0 Yes El No Other Explain flushed by Installer of underground sprinkler piping El Yes El No If powder-driven fasteners are used In concrete, has Yes No if no, explain representative sample testing be satisfactorily completed? Blank leafing Number used Locations Number removed gaskets Welding piping El Yes No If yes. Do you certify as the sprinkler contractor that welding procedures comply El Yes CJ No with the requirements of at least AWS 82.1? Welding Do you certify that the welding was performed by welders qualified In C3 Yes El No compliance with the requirements of at least AWS 82.1? Do you certify that the welding was carried out in compliance with a documented El Yea D No quality control procedure to ensure that all discs are retrieved, that openings In piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) Do you certify that you have a control feature to ensure that :Yes El No all cutouts (discs) are retrieved? I• fl r r fl — — a a n a • • a * fl From: 01/13/2014 17:51 #129 P.007/007 Hyd rate data rtam Nameplate provided c:eplae Yes S E] No I If no, explain Rernas Date left In service with all control valves open Signatuas Name of sprinkler contractor ç cct. crY..t*_r5 .5 Tests witnessed by For property owner (signed) Title . Date . ned) TM%W; Date Additional eplanatlons and noise kfl FIRE PROTECTION INC. 11465 Woodside Ave. 1st. Floor Santee CA 92071 Office 6191448-1962 Fax 6191448-1265 E Mall: andcorpl@aol.com