Loading...
HomeMy WebLinkAbout5810 NEWTON DR; ; FA110094; Permit12/13/24, 4:24 PM FA110094 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 5810 NEWTON DR Permit Type: FALARM Parcel No: 2121301900 Lot #: 0 Permit No: FA110094 Status: APPROVED Applied 10/25/2011 Approved: 11/2/2011 Reference No.: Issued: 11/2/2011 PC #: Inspector: Project Title: DEA/NTF BUILDING CARLSBAD INSTALLATION OF NEW FIRE ALARM SYSTEM Applicant: BERG ELECTRIC 650 OPPER ST ESCONDIDO CA 760-746-1003 Owner: KIM DOUGLAS W&HAE K 79683 ARNOLD PALMER LA QUINTA CA Fees ($) Add'I Fees ($) Total' ($) Balance ($) 385 0 385 0 about:blank ' 1/1 Page lof5 Record of Completion U Name of Protected Property: OEA!NTF Building Carlsbad Address: 5810 Newton Drive Carlsbad, CA 92008 Rep. of Protected Prop. (Name/Phone): Lucia Shamshoian (760)931-1134 Authority Having Jurisdiction: Carlsbad Fire Dept Address/Phone Number: (858)756-1126 Organization Name/Phone Representative Name/Phone Installer Berpelectrlc!(760)8394377 Supplier GE! Edwards Systems Tech. Service Organization Beruelectrlcl(760)839-8377 Location of Record (As-Built) Drawings: Owner Location of Owners Manuals: Owner Location of Test Reports: Owner A contract, dated Jan-12 , for test and inspection in accordance with NFPA Standard(s) No(s). 72 dated 2003 , is in effect. System Software Operating System Software Revision Level(s): 25 Application Software Revision Level(s): 2.5 Revision Complete by: JeremyCothran BergelectricCorporation(FireDivision) (name) (firm) 1. Type(s) of System or Service X NFPA 72, Chapter 6 Local If alarm is transmitted to location(s) off premises, list where received: National Monitorin Center 1-800462-1711 NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving the alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving the alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: How is alarm retransmitted: Page 2 of 5 NFPA 72, Chapter 8- Central Station Prime Contractor: Central Station Location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-Way Radio X Digital Alarm Communicator Two-Way Radio - Others Means of transmission of alarms to the public fire service communications center: System Location: NFPA 72, Chapter 9- Auxiliary Indicate type of connection: Local energy: - Shunt: - Parallel telephone: - Location and telephone number for receipt of signals: Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by on , includes the devices shown below, and has been in service since X NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) X NFPA 70, National Electric Code, Article 760 C) X Manufacturer's Instructions Other (specify): Signed: Jeremy Cothran Date: 12/812011 Organization: Bergelectric Corp. (Fire Division) Record of System Operation All operation features and functions of this system were tested by Jeremy Cothran on 1217/2011 , and found to be operation properly in accordance with the requirements of: X NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) () X NFPA 70, National Electric Code, Article 760 XManufacturer's Instructions Other (specify): Signed: - Jeremy cothran Organization: Bergelectrlc Corp. (Fire Division) Date: 12/8/2011 Signaling Line Circuits Quantity and Class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: I Style: 4 Class: B Page 3 of 5 5. Alarm-Initiating Devices and Circuits Quantity and Class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: I Style: 4 Class: B MANUAL Manual Stations: Noncoded _Transmitters Coded Addressable Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: Partial: Selective: Nonrequired:_________ Smoke Detectors I Ion Photo I Addressable Duct Detectors Ion Photo Addressable Heat Detectors FT RR FT/RT RC Addressable Sprinkler Waterfiow Indicators: Transmitters Noncoded Coded Addressable The alarm verification is disabled X or enabled , changed from seconds to Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR Coded Stations Noncoded Stations, Activating Transmitters (C) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 5(b) Manual, and 6(a), Guards Tour. SPRINKLER SYSTEM Check if provided X Valve Supervisory Signaling Attachments Building Temperature Points (C) Site Water Temperature Points Site Water Supply Level Points Electric Fire Pump: Fire Pump Power Fire Pump Running Phase Reversal Engine-Driven Fire Pump: Selector in Auto Position ______ Engine or Control Panel Trouble Fire Pump Running Engine-Driven Generator: (k) Selector in Auto Position (I) Control Panel Trouble Transfer Switches _Engine Running Other Supervisory Function(s) (specify): Page 4 of 5 7. Annunciator(s) Number: 2 Type: LCD Location: 1ST Floor Lobby, 2nd Floor DEA Reception 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 Emergency Voice/Alarm Service Quantity of voice alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephone or telephone jacks included in the system: Quantity and class of indicating appliance circuits connected to the system (see NFPA 72, Table 6.7) Quantity: 4 Style: V Class: B Types and quantities of alarm indicating appliances installed: Bells I Speakers With Visible (C) Horns 17 With Visible 17 Chimes With Visible Other: With Visible Visual appliances without audible 23 (9) 1 Local Annunciator 9. System Power Supplies Fire Alarm Control Unit: Nominal Voltage: 120 VAC Current Rating: 20 Amp Overcun-ent Protection: Type:Breaker Current Rating:20 Amp Location: Rm 243 Secondary (Standby): Storage Battery: Amp-Hour Rating 12 Ah Calculated capacity to drive system, in hours: 24 His Engine-driven generator dedicated to fire alarm system: Location of fuel storage: (C) Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 700 Legally Required Standby System described in NFPA 70, Article 701 Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 10. Comments: Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s) System deviations from the referenced NFPA standard(a) are: x /installation Foreman I Tech. 12/8/2011 contractor/supplier (title) (date) X t4-1T /installation Foreman! Tech. 121812011 for alarm service company (title) (date) x (signed) for Central Station (title) (date) Page 5 of 5 Upon gmpletion of the system's) satisfactory tests) witnessed (if required by the Authority Having Jurisdiction): Carlsbad Fire Dept 12/8/2011 of the Authority Having Jurisdiction (title) (date) Reprinted with permission from NFPA 72, National Fire Alarm Code, Copyright @2002, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard in its entirety.