City of Carlsbad
Fire Alarm Permit
Job Address: 5810 NEWTON DR
Permit Type: FALARM
Parcel No: 2121301900
Lot #: 0
Permit No: FA110094
Status: APPROVED
Applied 10/25/2011
Approved: 11/2/2011
Reference No.: Issued: 11/2/2011
PC #: Inspector:
Project Title: DEA/NTF BUILDING CARLSBAD INSTALLATION OF NEW FIRE
ALARM SYSTEM
Applicant:
BERG ELECTRIC
650 OPPER ST
ESCONDIDO CA
760-746-1003
Owner:
KIM DOUGLAS W&HAE K
79683 ARNOLD PALMER
LA QUINTA CA
Fees ($) Add'I Fees ($) Total' ($) Balance ($)
385 0 385 0
about:blank ' 1/1
Page lof5
Record of Completion
U
Name of Protected Property: OEA!NTF Building Carlsbad
Address: 5810 Newton Drive Carlsbad, CA 92008
Rep. of Protected Prop. (Name/Phone): Lucia Shamshoian (760)931-1134
Authority Having Jurisdiction: Carlsbad Fire Dept
Address/Phone Number: (858)756-1126
Organization Name/Phone Representative Name/Phone
Installer Berpelectrlc!(760)8394377
Supplier GE! Edwards Systems Tech.
Service Organization Beruelectrlcl(760)839-8377
Location of Record (As-Built) Drawings:
Owner
Location of Owners Manuals:
Owner
Location of Test Reports:
Owner
A contract, dated Jan-12 , for test and inspection in accordance with NFPA
Standard(s) No(s). 72 dated 2003 , is in effect.
System Software
Operating System Software Revision Level(s): 25
Application Software Revision Level(s): 2.5
Revision Complete by: JeremyCothran BergelectricCorporation(FireDivision)
(name) (firm)
1. Type(s) of System or Service
X NFPA 72, Chapter 6 Local
If alarm is transmitted to location(s) off premises, list where received:
National Monitorin Center 1-800462-1711
NFPA 72, Chapter 8 - Remote Station
Telephone numbers of the organization receiving the alarm:
Alarm:
Supervisory:
Trouble:
If alarms are retransmitted to public fire service communications center or others, indicate location and
telephone number of the organization receiving alarm:
NFPA 72, Chapter 8 - Proprietary
Telephone numbers of the organization receiving the alarm:
Alarm:
Supervisory:
Trouble:
If alarms are retransmitted to public fire service communications center or others, indicate location and
telephone number of the organization receiving alarm:
How is alarm retransmitted:
Page 2 of 5
NFPA 72, Chapter 8- Central Station
Prime Contractor:
Central Station Location:
Means of transmission of signals from the protected premises to the central station:
McCulloh Multiplex One-Way Radio
X Digital Alarm Communicator Two-Way Radio
-
Others
Means of transmission of alarms to the public fire service communications center:
System Location:
NFPA 72, Chapter 9- Auxiliary
Indicate type of connection: Local energy:
-
Shunt:
- Parallel telephone: -
Location and telephone number for receipt of signals:
Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts,
ground faults, and improper branching, but prior to conducting operational acceptance tests.)
This system has been installed in accordance with the NFPA standards as shown below, was inspected
by on , includes the devices shown below,
and has been in service since
X NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply)
X NFPA 70, National Electric Code, Article 760 C) X Manufacturer's Instructions
Other (specify):
Signed: Jeremy Cothran Date: 12/812011
Organization: Bergelectric Corp. (Fire Division)
Record of System Operation
All operation features and functions of this system were tested by Jeremy Cothran
on 1217/2011 , and found to be operation properly in accordance with the requirements of:
X NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) () X NFPA 70, National Electric Code, Article 760
XManufacturer's Instructions
Other (specify):
Signed: - Jeremy cothran
Organization: Bergelectrlc Corp. (Fire Division) Date: 12/8/2011
Signaling Line Circuits
Quantity and Class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1):
Quantity: I Style: 4 Class: B
Page 3 of 5
5. Alarm-Initiating Devices and Circuits
Quantity and Class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1):
Quantity: I Style: 4 Class: B
MANUAL
Manual Stations: Noncoded _Transmitters Coded Addressable
Combination Manual Fire Alarm and Guard's Tour Coded Stations
AUTOMATIC
Coverage: Complete: Partial:
Selective: Nonrequired:_________
Smoke Detectors I Ion Photo I Addressable
Duct Detectors Ion Photo Addressable
Heat Detectors FT RR FT/RT RC Addressable
Sprinkler Waterfiow Indicators: Transmitters Noncoded Coded Addressable
The alarm verification is disabled X or enabled , changed from seconds to
Other (list):
6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices)
GUARD'S TOUR
Coded Stations
Noncoded Stations, Activating Transmitters
(C) Compulsory Guard Tour System Comprised of Transmitter Stations and
Intermediate Stations
NOTE: Combination devices recorded under 5(b) Manual, and 6(a), Guards Tour.
SPRINKLER SYSTEM
Check if provided
X Valve Supervisory Signaling Attachments
Building Temperature Points
(C) Site Water Temperature Points
Site Water Supply Level Points
Electric Fire Pump:
Fire Pump Power
Fire Pump Running
Phase Reversal
Engine-Driven Fire Pump:
Selector in Auto Position
______ Engine or Control Panel Trouble
Fire Pump Running
Engine-Driven Generator:
(k) Selector in Auto Position
(I) Control Panel Trouble
Transfer Switches
_Engine Running
Other Supervisory Function(s) (specify):
Page 4 of 5
7. Annunciator(s)
Number: 2 Type: LCD Location: 1ST Floor Lobby, 2nd Floor DEA Reception
8. Alarm Notification Appliances and Circuits
NFPA 72, Chapter 6 Emergency Voice/Alarm Service
Quantity of voice alarm channels: Single: Multiple:
Quantity of speakers installed: Quantity of speaker zones:
Quantity of telephone or telephone jacks included in the system:
Quantity and class of indicating appliance circuits connected to the system (see NFPA 72, Table 6.7)
Quantity: 4 Style: V Class: B
Types and quantities of alarm indicating appliances installed:
Bells I
Speakers With Visible
(C) Horns 17 With Visible 17
Chimes With Visible
Other: With Visible
Visual appliances without audible 23
(9) 1 Local Annunciator
9. System Power Supplies
Fire Alarm Control Unit: Nominal Voltage: 120 VAC Current Rating: 20 Amp
Overcun-ent Protection: Type:Breaker Current Rating:20 Amp Location: Rm 243
Secondary (Standby):
Storage Battery: Amp-Hour Rating 12 Ah
Calculated capacity to drive system, in hours: 24 His
Engine-driven generator dedicated to fire alarm system:
Location of fuel storage:
(C) Emergency or Standby System used as backup to Primary Power Supply, instead of using a
Secondary Power Supply:
Emergency System described in NFPA 70, Article 700
Legally Required Standby System described in NFPA 70, Article 701
Optional Standby System described in NFPA 70, Article 702, which also meets the
performance requirements of Article 700 or 701
10. Comments:
Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s)
System deviations from the referenced NFPA standard(a) are:
x /installation Foreman I Tech. 12/8/2011
contractor/supplier (title) (date)
X t4-1T /installation Foreman! Tech. 121812011
for alarm service company (title) (date)
x
(signed) for Central Station (title) (date)
Page 5 of 5
Upon gmpletion of the system's) satisfactory tests) witnessed (if required by the Authority Having Jurisdiction):
Carlsbad Fire Dept 12/8/2011
of the Authority Having Jurisdiction (title) (date)
Reprinted with permission from NFPA 72, National Fire Alarm Code, Copyright @2002, National Fire Protection
Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on
the referenced subject which is represented only by the standard in its entirety.