Loading...
HomeMy WebLinkAbout3115 MELROSE DR; ; AS060153; Permit1/29/25,12:36 PM AS060153 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS060153 Job Address: 3115 MELROSE DR Permit Type: SPRINK Parcel No: 2218801300 Lot #: 0 Reference No.: Status: ISSUED Applied 6/27/2006 Approved: 6/26/2006 Issued: 6/26/2006 PC #: Inspector: Project Title: OPUS POINT, LOT 25 FIRE SPRINKLER INSPECTIONS @ $60/EA Applicant: Owner: OPUS WEST CORP 4350 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 180 0 180 0 about:blank 1/1 City of Carlsbad 08-15-2006 Fire Department Permit Permit No: AS060153 Job Address: 3115 MELROSE DR CBAD Permit Type: SPRINK Subtype: COMM Parcel No: 2218801300 Lot #: 0 Fire Dept Ref#: AS060153 Building Permit#: CB053439 Location: Project Title: OPUS POINT, LOT 25 Description: FIRE SPRINKLER INSPECTIONS @ $60/EA Contractor: ADVANCE FIRE PROTECTION Phone: 714-526-2231 1451 W.• LAMBERT RD Fax: LA HABRA, CA 90631 Status: ISSUED Applied: 06/27/2006 Issued: 06/26/2006 Entered By: BSM Total Fees: $180.00 Total Payments To Date: $0.00 #of Systems I # of Additional Risers or Floors 0 Plan Check Fee $0.00 Additional Plan Check Fee $0.00 # of Heads 0 $0.00 Permit Fee $0.00 Additional Permit Fee $0.00 Re-Inspection Fee 0 $0.00 ByPass Meter Fee $0.00 ByPass Addtl Meter Fee $0.00 Other $180.00 Additional Fees $0.00 TOTAL PERMIT FEES $180.00 NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as"fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. El 4 I(-Z3 ~6 APPROVED 410 APPROVED FS NOTED' NOT APPROVED RESUBMIT K!NG IS ONLY FOR CGFORMAN THE D ES! G CGDOE I E THE ELT AND CCPUANOE iH THE IF3RftAflDD 0 IN THE CONTRACT DOU"ETS. CCNTR,ACTCR IS RESPONSIBLE Ffl LEDS!ODS ID BE CODFfRMED :) GGPflLPJED AT TIE JOB S, IF AD ftP COCNATION OF THE IRKOF AL IRA&ES. - - Fire Protection by Computer Design Advance Fire Protection Co. 1451 West Lambert Road La Habra CA 90631 Fax (562) 691-5482 562-691-0918 Job Name : OPUS POINT - LOT 25 Building : LOT 25 Location 3115 MELROSEDR.-CARLSBAD, CA. System 2ND FLOOR Contract : 06-0118 Data File : 06-0118.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Made By System Type (X) Wet Dry Deluge Preaction Other Date Sprinkler/Nozzle Make RELIABLE Model F1FR Size " ORIFICE K-Factor 5.62 Temp. Rat.155°F Advance Fire Protection Co. Page OPUS POINT - LOT 25 - Date 6-5-06 Hydraulic Design Information Sheet Name - OPUS POINT Date - 6-5-06 Location - 3115 MELROSE DR.-CARLSBAD, CA. Building - LOT 25 System No. - 2ND FLOOR Contractor - ADVANCE FIRE PROTECTION Contract No. - 06-0118 Calculated By - MATT KRIVOLAVY Drawing No. - FP-3 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 30' Occupancy - OFFICES (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 C ) 2 C ) 3 C ) Ex.Haz. NFPA 231 C ) NFPA 231C Figure Curve Other Specific Ruling Area of Sprinkler Operation - 1500 SF Density - .10 GPM Area Per Sprinkler - 168 SF Elevation at Highest Outlet - 29' AFF Hose Allowance - Inside - 100 GPM Rack Sprinkler Allowance - N/A Hose Allowance - Outside - N/A Note TWO HEADS CALCULATED OFF OF EVERY OUTLET FOR A TOTAL OF 18 HEADS Calculation Flow Required - 330.93 Press Required - 103 At BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 1-18-06 Cap. - T Time of Test - 9:18 AM Rated Cap.- Elev.- E Static Press - 150 PSI @ Press - R Residual Press - 140 PSI Elev. - Well Flow - 2632 GPM Proof Flow S Elevation - GRADE U P Location - EXISTING CITY WATER MAIN IN LIONSHEAD AVE. P L Source of Information - WATER FLOW TEST WITH MARK SODERGERG-CARLSBAD FIRE INS Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage C ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: S Y S T E M D E S I G N Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 0 VANCE FIRE PROTECTION CO, INC. 1451 W. Lambert Road La Habra, CA 90631 (562)691.0918 voice (562) 6915482 fax State License Number 259936 Witness of Flow Job Name Address 31 ctO Uo i-k9 City Location of Hydrants r1O') .- 3(q0 L)00$1t)9ç rA Pitot Reading i; )ç2... Orifice Size 2"b )c2 Static Pressure (0 Residual Pressure 140 Gallons Flowing 232 6f'V\ Witness i11!1,k_OD211E- Title /& /fU5f3Lrcr612 Company C4iI5/P1n_12EP7 Date /a 3i4 Time Water Supply Curve (C) Advance Fire Protection Co. Page 2 OPUS POINT - LOT 25 Date 6-5-06 - City Water Supply: Cl - Static Pressure : 135 PSI C2 - Residual Pressure: 126 PSI C2 - Residual Flow : 2632 GPM 150 130 R 110 E 100 90 80 U 70 R6° E 50 40 30 20 10 300 600 900 1200 1500 1800 2100 2400 2700 ) FLOW (NA 1.85 Dl -Elevation : 12.560 PSI D2 - System Flow : 330.94 GPM D2 - System Pres re : 112.328 PSI Hose(Demand) : GPM D3 - System Demand : 430.94 GPM Safety Margin : 22.356 PSI 140et - - - P 120DZ - 13 --Di a .us.Li..s I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram . Advance Fire Protection Co. Page 3 OPUS POINT - LOT 25 Date 6-5-06- A 4- 16.80 C 3 - 16.96 C 4- 33.76 DBLE 1 - 59.99 2 -+ 25.49 3 - 8.27 4 4- 42.12 5 -. 77.81 6 T 59.99 1 77.81 7 -* 60.54 8 - 25.83 9 - 8.12 10 4- 42.16 11 4- 78.03 13 1 120.52 14 0.24 15 - 22.36 16 - 22.36 12 - 32.21 17 1 8.24 1 30.60 15 - 30.60 18 1 218.65 19 4- 24.38 20 C 87.91 t 243.03 21 30.13 22 -1 57.77 1 57.77 23 4- 29.01 24 C 28.77 1 28.77 25 4- 28.77 26 1 4- 59.99 7 4- 120.52 14 - 112.28 19 4- 87.91 21 4- 57.77 23 4- 28.77 25 6 4- 77.81 13 4- 155.8417 4- 188.05 18 4- 218.6520 4- 243.0322 26 - 28.77 24 4- 57.77 22 4- 330.93 27 C 330.93 C 126.55 28 4- 18.99 29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram 1 18.99 1 18.99 30 <- 19.15 31 .1. 38.14 C 38.14 27 166.2432 33 <-. 24.08 34 .L 24.08 C 24.08 35 -. 24.28 36 .- 48.37 C 48.37 37 <- 25.00 38 39 <- 19.47 40 C 107.08 41 - 33.72 42 1' 330.93 C 126.55 28 - 18.99 30 -4 38.14 27 +- 126.55 39 C 8.99 1 19.15 1 66.24 t 19.47 29 - 18.9931 - 38.1432 - 204.38413 1 223.85 34 - 24.08 36 - 48.37 38 +-. 73.36 43 +.- 107.08 4 1 .- 73.36 37 - 48.37 35 #- 24.08 33 <- 223.85 43 1 297.21 <-. 297.21 42 -. 330.93 44 *- 330.93 TOR2 4_. 330.93 BOR2 4- 430.94 UG 430.94 CITY Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary Advance Fire Protection Co. OPUS POINT - LOT 25 Fitting Legend Abbrev. - Name Page 4 Date 6-5-06 A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90 Standard Elbow F 45' Elbow G Gate Valve K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow Q Flow Control Valve S Swing Check Valve T 90' Flow thru Tee V Detector Check Valve W Wafer Check Valve Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary Advance Fire Protection Co. OPUS POINT - LOT 25 Page 5 Date 6-5-06 Unadjusted Fittings Table 1/2 3/4 1 1 1/4 1 1/2 2 21/2 3 3 1/2 4 A 7.7 21.5 17.0 B 7.0 10.0 12.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 9.5 17.0 28.0 E 1.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 1.8 2.2 2.6 3.0 3.4 G 1.0 1.0 1.0 . 1.0 2.0 K 14.0 14.0 L 1.0 1.0 1.7 2.0 2.0 3.5 4.3 5.0 5.0 6.8 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 Q 18.0 29.0 35.0 S 4.0 5.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 V 14.0 14.0 w 10.3 Z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 F 4.2 5.0 5.0 11.0 . 13.0 17.0 19.0 21.0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 K 36.0 55.0 45.0 L 8.5 10.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 Q 33.0 S 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81.0, 91.0 101.0 121.0 V 36.0 55.0 45.0 W 13.1 ' 31.8 35.8 27.4 Z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Advance Fire Protection Co. Page 6 OPUS POINT - LOT 25 Date 6-5-06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. A 27.0 5.62 8.94 na 16.8 .1 168 8.94 B 27.0 5.62 9.1 na 16.96 .1 168 8.94 C 29.0 9.87 na 29.0 28.68 na 2 29.0 K=K@DBLE 12.27 na 34.5 3 29.0 K=K@DBLE 11.75 na 33.76 4 29.0 K=K@DBLE 11.82 na 33.85 5 29.0 K=K@DBLE 13.13 na 35.69 7 29.0 29.11 na 8 29.0 K = K @ DBLE 12.42 na 34.7 9 29.0 K=K@DBLE 11.89 na 33.95 10 29.0 K =K@DBLE 11.95 na 34.04 11 29.0 K =K@DBLE 13.27 na 35.87 14 29.0 30.66 na 15 29.0 30.87 na 16 29.0 30.74 na 12 29.0 K =K@DBLE 30.71 na 54.57 19 29.0 32.77 na 21 29.0 33.47 na 23 29.0 33.88 na 25 29.0 33.99 na 6 29.0 36.47 na 13 29.0 36.73 na 17 29.0 37.68 na 18 29.0 38.81 na 20 29.0 40.04 na 26 29.0 43.86 na 24 29.0 43.9 na 22 29.0 44.23 na 28 29.0 58.88 na 30 29.0 58.82 na 27 29.0 58.64 na 33 29.0 61.77 na 35 29.0 61.69 na 37 29.0 61.41 na 39 29.0 60.01 na 41 29.0 60.88 na 29 29.0 63.44 na 31 29.0 63.46 na 32 29.0 63.53 na 40 29.0 64.79 na 34 29.0 68.86 na 36 29.0 68.89 na 38 29.0 69.0 na 43 29.0 69.33 na 42 29.0 73.39 na 44 29.0 74.5 na TOR2 12.5 91.87 na BOR2 0.0 103.01 na 100.0 UG 0.0 103.05 na CITY 0.0 112.33 na The maximum velocity is 15.33 and it occurs in the pipe between nodes 11 and 13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 7 OPUS POINT - LOT 25 Date 6-5-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Fin A 16.80 1.049 2E 2.000 10.000 8.940 K Factor =5.62 to 120 IT 5.000 9.000 -0.866 C 16.8 0.0943 19.000 1.791 Ve! = 6.237 0.0 16.80 9.865 KFactor= 5.35 B 16.96 1.049 1E 2.000 10.000 9.102 K Factor = 5.62 to 120 IT 5.000 7.000 -0.866 C 16.96 0.0959 17.000 1.631 Vel = 6.296 C 16.80 1.049 IT 5.000 0.500 9.865 to 120 5.000 0.0 DBLE 33.76 0.3427 5.500 1.885 Ve! = 12.533 0.0 33.76 11.750 K Factor = 9.85 1 -59.99 1.442 IT 7.432 70.420 28.682 to 120 7.432 0.0 2 -59.99 -0.2108 77.852 -16.414 Vel= 11.785 2 34.50 1.442 12.000 12.270 K Factor @ node DBLE to 120 0.0 0.0 3 -25.49 -0.0433 12.000 -0.519 Ve! = 5.008 3 33.76 1.442 12.000 11.751 K Factor @ node DBLE to 120 0.0 0.0 4 8.27 0.0054 12.000 0.065 Ye! = 1.625 4 33.85 1.442 12.000 11.815 K Factor @ node DBLE to 120 0.0 0.0 5 42.12 0.1096 12.000 1.315 Ye! = 8.275 5 35.69 1.442 IT 7.432 61.000 13.130 K Factor @ node DBLE to 120 7.432 0.0 6 77.81 0.3411 68.432 23.344 Ye! = 15.286 0.0 77.81 36.474 K Factor = 12.88 7 -60.54 1.442 IT 7.432 70.420 29.109 to 120 7.432 0.0 8 -60.54 -0.2144 77.852 -16.693 Ye!= 11.893 8 34.71 1.442 12.000 12.418 K Factor @ node DBLE to 120 0.0 0.0 9 -25.83 -0.0443 12.000 -0.532 Yel = 5.074 9 33.95 1.442 12.000 11.886 K Factor @ node DBLE to 120 0.0 0.0 10 8.12 0.0052 12.000 0.063 Ye! = 1.595 10 34.04 1.442 12.000 11.948 K Factor @ node DBLE to 120 0.0 0.0 11 42.16 0.1098 12.000 1.317 Ve1= 8.282 11 35.87 1.442 IT 7.432 61.000 13.266 K Factor @ node DBLE to 120 7.432 0.0 13 78.03 0.3429 68.432 23.466 Ye! = 15.329 0.0 78.03 36.732 KFactor= 12.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 8 OPUS POINT - LOT 25 Date 6-5-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 14 8.24 1.682 2T 9.900 61.420 30.664 to 120 19.799 0.0 15 8.24 0.0025 81.219 0.206 Vel= 1.190 15 -30.60 1.682 8.000 30.870 to 120 0.0 0.0 16 -22.36 -0.0160 8.000 -0.128 Vet = 3.229 16 0.0 1.442 1.000 30.742 to 120 0.0 0.0 12 -22.36 -0.0340 1.000 -0.034 Vel = 4.393 12 54.57 1.442 IT 7.432 97.000 30.708 K Factor @ node DBLE to 120 7.432 0.0 17 32.21 0.0667 104.432 6.968 Vel = 6.328 0.0 32.21 37.676 K Factor = 5.25 15 30.60 1.442 1E 3.716 119.750 30.870 to 120 IT 7.432 11.148 0.0 18 30.6 0.0607 130.898 7.943 Vel = 6.011 0.0 30.60 38.813 K Factor = 4.91 19 24.38 1.442 2T 7.432 167.500 32.769 to 120 14.864 0.0 20 24.38 0.0399 182.364 7.268 Vet = 4.790 0.0 24.38 40.037 KFactor= 3.85 21 30.13 1.442 2T 7.432 167.500 33.471 to 120 14.864 0.0 22 30.13 0.0590 182.364 10.754 Vet = 5.919 0.0 30.13 44.225 KFactor= 4.53 23 29.01 1.442 2T 7.432 167.500 33.877 to 120 14.864 0.0 24 29.01 0.0550 182.364 10.026 Vel = 5.699 0.0 29.01 0 43.903 K Factor = 4.38 25 28.77 1.442 2T 7.432 167.500 33.989 to 120 14.864 0.0 26 28.77 0.0541 182.364 9.873 Vel = 5.652 0.0 28.77 43.862 K Factor = 4.34 1 59.99 2.157 14.420 28.682 to 120 0.0 0.0 7 59.99 0.0297 14.420 0.428 Vet = 5.267 7 60.53 2.157 14.420 29.109 to 120 0.0 0.0 14 120.52 0.1078 14.420 1.555 Vet = 10.582 14 -8.24 2.157 22.250 30.664 to 120 0.0 0.0 19 112.28 0.0946 22.250 2.105 Vet = 9.858 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 9 OPUS POINT - LOT 25 Date 6-5-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 19 -24.37 2.157 11.670 32.769 to 120 0.0 0.0 21 87.91 0.0602 11.670 0.702 Vel = 7.718 21 -30.14 2.157 14.670 33.471 to 120 0.0 0.0 23 57.77 0.0277 14.670 0.406 Vel = 5.072 23 -29.00 2.157 14.670 33.877 to 120 0.0 0.0 25 28.77 0.0076 14.670 0.112 Vel = 2.526 0.0 28.77 33.989 K Factor = 4.93 6 77.81 2.635 14.420 36.472 to 120 0.0 0.0 13 77.81 0.0181 14.420 0.261 Vel = 4.578 13 78.03 2.635 14.420 36.733 to 120 0.0 0.0 17 155.84 0.0655 14.420 0.944 Vel= 9.169 17 32.21 2.635 12.250 37.677 to 120 0.0 0.0 18 188.05 0.0927 12.250 1.135 Vel = 11.064 18 30.60 2.635 10.000 38.812 to 120 0.0 0.0 20 218.65 0.1225 10.000 1.225 Vel = 12.864 20 24.38 2.635 IT 16.474 11.670 40.037 to 120 16.474 0.0 22 243.03 0.1489 28.144 4.191 Vel = 14.298 0.0 243.03 44.228 KFactor 36.54 26 28.77 2.635 14.670 43.860 to 120 0.0 0.0 24 28.77 0.0029 14.670 0.042 Vel = 1.693 24 29.00 2.635 IT 16.474 14.670 43.902 to 120 16.474 0.0 22 57.77 0.0104 31.144 0.325 Vel= 3.399 22 273.16 3.26 2L 6.720 120.500 44.227 to 120 IT 20.159 33.599 0.0 27 330.93 0.0935 154.099 14.408 Vel = 12.720 0.0 330.93 58.635 KFactor= 43.22 28 18.99 1.442 2T 7.432 167.000 58.875 to 120 14.864 0.0 29 18.99 0.0251 181.864 4.566 Vel= 3.731 0.0 18.99 63.441 KFactor= 2.38 30 19.15 1.442 2T 7.432 167.000 58.824 to 120 . 14.864 0.0 31 19.15 0,0255 181.864 4.637 Vel = 3.762 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 10 OPUS POINT - LOT 25 Date 6-5-06 Hyd. Qa Die. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '"' Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 19.15 63.461 K Factor = 2.40 27 166.24 3.26 IT 20.159 167.000 58.635 to 120 P20.159 0.0 32 166.24 0.0262 187.159 4.896 Vel = 6.390 0.0 166.24 63.531 KFactor= 20.86 33 24.08 1.442 2T 7.432 167.000 61.773 to 120 14.864 0.0 34 24.08 0.0390 181.864 7.084 Vet = 4.731 0.0 24.08 68.857 K Factor = 2.90 35 24.28 1.442 2T 7.432 167.000 61.694 to 120 14.864 0.0 36 24.28 0.0396 181.864 7.194 Vel= 4.770 0.0 24.28 68.888 K Factor = 2.93 37 25.00 1.442 2T 7.432 167.000 61.407 to 120 14.864 0.0 38 25.0 0.0418 181.864 7.593 Vel = 4.911 0.0 25.00 69.000 K Factor = 3.01 39 19.47 1.442 2T 7.432 167.000 60.013 to 120 14.864 0.0 40 19.47 0.0263 181.864 4.782 Vel = 3.825 0.0 19.47 64.795 KFactor = 2.42 41 33.72 1.442 2E 3.716 150.000 60.879 to 120 2T 7.432 22.296 0.0 42 33.72 0.0726 172.296 12.513 Vel = 6.624 0.0 33.72 73.392 K Factor = 3.94 28 -18.99 2.157 14.670 58.875 to 120 0.0 0.0 30 -18.99 -0.0035 14.670 -0.052 Vel = 1.667 30 -19.15 2.157 14.670 58.824 to 120 0.0 0.0 27 -38.14 -0.0128 14.670 -0.188 Vel = 3.349 27 164.69 2.157 11.670 58.635 to 120 0.0 0.0 39 126.55 0.1180 11.670 1.377 VeI= 11.111 39 -19.47 2.157 10.000 60.013 to 120 0.0 0.0 41 107.08 0.0866 10.000 0.866 Vel = 9.402 41 -33.72 2.157 12.250 60.879 to 120 0.0 0.0 37 73.36 0.0430 12.250 0.527 Vet = 6.441 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 11 OPUS POINT - LOT 25 Date 6-5-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt P€/UL Eqv. Ln. Total Pf Pn 37 -24.99 2.157 14.420 61.407 to 120 0.0 0.0 35 48.37 0.0199 14.420 0.287 Vel = 4.247 35 -24.29 2.157 14.420 61.694 to 120 0.0 0.0 33 24.08 0.0055 14.420 0.079 Vel = 2.114 0.0 24.08 61.773 K Factor = 3.06 29 18.99 2.635 14.670 63.441 to 120 0.0 0.0 31 18.99 0.0014 14.670 0.020 Ve1= 1.117 31 19.15 2.635 14.670 63.461 to 120 0.0 0.0 32 38.14 0.0048 14.670 0.071 Vel = 2.244 32 166.24 2.635 11.670 63.532 to 120 0.0 0.0 40 204.38 0.1081 11.670 1.261 Vel = 12.024 40 19.47 2.635 IT 16.474 19.000 64.793 to 120 16.474 OM 43 223.85 0.1279 35.474 4.537 Vel = 13.170 0.0 223.85 69.330 K Factor = 26.88 34 24.08 2.635 14.420 68.860 to 120 0.0 0.0 36 24.08 0.0021 14.420 0.030 Vel = 1.417 36 24.29 2.635 14.420 68.889 to 120 0.0 0.0 38 48.37 0.0075 14.420 0.108 Vel = 2.846 38 24.99 2.635 IT 16.474 4.000 68.998 to 120 16.474 0.0 43 73.36 0.0162 20.474 0.332 Vel = 4.316 43 223.85 3.26 IT 20.159 26.130 69.330 to 120 1L 6.720 26.879 0.0 42 297.21 0.0766 53.009 4.063 Vel = 11.424 42 33.72 3.26 1L 6.720 5.170 73.393 to 120 6.720 0.0 44 330.93 0.0935 11.890 1.112 Vel = 12.720 44 0.0 3.26 41, 6.720 82.420 74.505 to 120 26.879 7.146 TOR2 330.93 0.0935 109.299 10.219 Ye! = 12.720 TOR2 0.0 3.26 1L 6.720 11.500 9.1.870 to 120 lB 13.440 49.727 5.414 BOR2 330.93 0.0935 1Z 9.408 61.227 5.725 Vel 12.720 IT 20.159 BOR.2 100.01 8.249 1L 19.228 15.000 103.008 Qa= 100 to. 140 19.228 0.0 UG 430.94 0.0013 34.228 0.043 Vel = 2.587 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Advance Fire Protection Co. Page 12 OPUS PONT - LOT 25 Date 6-5-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn UG 0.0 8.385 61, 23.657 60.000 103.051 to 150 IT 63.691 .212.900 9.000 Fixed loss = 9 CITY 430.94 0.0010 1G 7.279 272.900 0.276 Ve1= 2.504 .0 430.94 - 112.327 K Factor 40.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary Advance Fire Protection Co. Page 13 OPUS PONT - LOT 25 Date 6-5-06 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length 11 13 73.000 14 15 49.420 12 17 109.000 1 2 58.420 5 6 73.000 7 8 58.420 11 13 61.000 14 15 61.420 12 17 97.000 1 2 70.420 5 6 61.000 7 8 70.420 Flow Pressure Pressure Required Required Differential Area Calculated I 430.94 112.328 -0.576 Right 12.000 I 430.43 112.904 0.000 Right 24.000 I 429.72 112.897 -0.007 Typical Distance Between Heads = 12.000 Split Point Used in Worst Area Peaked = 3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary Split Point Used in Area Calculated = 3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Series 709DCDA and 909RPDA are designed to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of non-potable quality from being pumped orsyphoned into the safe drinking watersystem. Detects leaks . . . with emphasis on the cost of unaccountable water; incorporates a meter which allows the water utility to: Detect leaks underground that historically create great annual cost due to waste. It provides a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All 709DCDA sizes are standardly equipped with AWWA epoxy coated ULJFM listed OS&Y gate valves, CFM (cubic feet per minute) S x 3/4" meter and ball type test cocks. eries 909RPDA Reduced Pressure Detector Assembly: When applications call for maximum protection, use 909RPDA with relief vent to atmosphere. \ 50 100 .150 200 250 300 350 400 450 500 550 600 FLOW—G.P.M. s. 709DCDA Sizes 6," 8" 10" Double Check Detector Assembly/Reduced Pressure Detector Assembly Series 7090CDAI909RPDA No. 7090CDAOSYRW-CFM No special tools required for servicing Compact for economy combined with performance Design simplicity for easy maintenance Furnished with Recordall 3/4" bronze meter, model 25, see options DIMENSIONS-WEIGHTS (are approximate) OPEN I G DIMENSIONS (Inches) WEIGH1\(Lbs.) CS 1/ 1/ ize A A B C U E F F G H J OS&Y OS&Y 3" 24 26 12 7'/2 7 8 190 250 4" 34 37910 9 1/s 23h 6 15403490 6" 411/2 44 21 11 15 10½1/2 J4041/4 8Y2314 32% 8 16 727 820 8" 52 55 26 13 19 111/2 3/4 39% 9 17 1327 1656 10" 6467 32 16 22 13 5/8 48 101/4 18 2093 2250 Li FM approved backf low preventers must include FM approved OS&Y gate valves. New 99ORPDA Reduced Pressure Detector Assembly 4"- 8" Send for ES-99ORPDA. !MATERIALS Epoxy coated'cast irzo"fn body, brorze heat and disc holder; stainLess steel trim and durable, tiht-seatig rubber dhck valve discs. All sizes furiüshed with bronzebody ball valve test ... Eurnisediith outside' stem añd yoke (OS&Y) gate voIve. . ............... No 709DCDA by pass line unit consists of an ap proved No. 09döible check valve, assembly and water meter No. 909R8DA bypass line unit.conJstof a No 009Th'duced pFèsuie zone backfl6réventer ,and water, meter: . . 'rid tof PL-BPDL for. ilftistrated price list., 10PTI0NS (can be combined) Suttix . . CEM- ,-,rth cubr ftpern it t GPM - with gallons per- em Sr I 0 r .- LF iSthout shut-off \alv&s- . PRESSURE-TEMPERATUAE Size.3' thr6ugh10' areuitable -far supply -- prdssures up to 175 PSI and water tenperatu mc to 110Frnàxirjiurñ . . . -STANDARDS,'-'- -, .. . ,USCMãnual 8th,Editionf. 709DCDA meets or .00. exbd#efbllwing standrdfô(dóuble- check alveasmblies: A.S.S.E. Std. No. 1048,' (1047 f6r 9U9RPDA), AWWA Std. C51089Ic(C51189) for 9O9RPDA), UL clasified file No X3 E185, listed under CSA B634standard--- ... . -, . tDoes,not indicate ,approvatstaws. Refer to engineehtg iedifiction h'eet. for approved sizes aà.d1productnurTbers . . . CARA°CITY v.-. ........ - ._ .. .• 3 16 Jo9uC- Serie-709DC64 sizes 3"-'& -4" - 14 --- --- ----- ------------ - 12 1 10 o --__ - - a: 8 X /5 •- — w 6 - - W~ W ~F-PA-M~ I 11,411 'Is FEATURES Resilient wedge shut-offs Body construction epoxy coated cast iron Replaceable bronze seats Stainless steel iflteFitaliiarts Max. flow at low pressure drop