3115 MELROSE DR; ; FA070011; Permit
1/29/25,12:36 PM FA070011 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA070011 Job Address: 3115 MELROSE DR Status: ISSUED Permit Type: FALARM Applied 1/31/2007 Parcel No: 2218801300 Approved: 1/31/2007 Lot #: 0 Reference No.: Issued: 1/31/2007 PC #: Inspector: Project Title: OPUS POINT 2. LOT 25 TWO FIRE ALARM INSPECTIONS @ $62/EA Applicant: BERG ELECTRIC 650 OPPER ST ESCONDIDO CA 760-746-1003 Owner: OPUS WEST CORP 4350 LA JOLLA VILLAGE DR #110 SAN DIEGO CA rFees ($) Add'I Fees ($) J Total ($) Balance ($) 124 0 124 0 about:blank 1/1 Bergelectric Corp. Contractors & Engineers OPUS POINT 2, LOT 25 3115 MELROSE DRIVE CARLSBAD, CA 92009 PERMIT # CB053439 APPLICANT: BERGELECTRIC CORP. 650 OPPER STREET ESCONDIDO, CA 92029 (760) 746-1003 CONTACT: GRAIG RHODES FIRE ALARM SUBMITTAL F-1 APPROVED.PAj 1/0 67 APPROVED PS NOTED NOT APPFOED, RESUBMIT CIiCY 0 iS CL FOP CU)MAN . SG I ucpL; ME THE CUACT - TE fi FRi.TOR iS 'ESN1HSU?LE YS'.S IU dE COFRMED A0 •. t.L) AT ThE JOB S1F OP COORATON OF THE "'wRv ur /U. RAM. APPROVED $S Ca rITTED CARLSBAD PIVE frPARTMENT FOR REVIEW AND APPROVAL MARK1NCi 650 Opper Street • Escondido, CA 92029 9 Tel (760) 746-1003 9 Fax (760) 746-4619 • C10485046 S C Bergelectric Corp. tractors & Engineers TABLE OF CONTENTS FIRE ALARM SUBMITTAL ITEM TABNO FIRE ALARM CONTROL PANEL INITIATING DEVICES 2 INPUT/OUTPUT DEVICES 3 NOTIFICATION APPLIANCES 4 BATTERIES 5 C 650 Opper Street 9 Escondido, CA 92029 9 Tel (760) 746-1003 9 Fax (760) 746-4619 • C10485046 Bergelectric Corp. Contractors & Engineers S II FIRE ALARM CONTROL PANEL S S 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 • Fax (760) 746-4619 • C10485046 GE EST Fire & Life Safety S Security Control Panels S Overview GE Security's QS1 life safety control panel brings big-system intel- ligent control to small applications. Designed for easy setup and simple installation, QuickStart lives up to its name in every respect. QS1's exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Devices come on-line in no time as well, thanks to 051's built-in barcode scanner port. A simple pass of the optional scanner is all it takes to store device in- formation in the QuickStart database. The scanner can also be used for quick and easy text entry when assembling custom messages. QS1's setup routine is deceptively simple, considering this sys- tem's robust features. Supporting up to 250 intelligent detectors and modules, QS1 takes full advantage of GE Security's exclusive Signature Series technology, which provides electronic addressing, automatic device mapping, environmental compensation, and true multisensor detection. QuickStart's innovative design makes it easy to add a dialer or extra auxiliary relays. Quick-Lok option cards snap onto QS1's easily-ac- cessible DIN mounting rails. QS1 also supports as many as eight remote annunciators and up to 30 programmable front panel switches with dual LEDs for system control and display. QS1 is as simple to operate as it is to set up. Its large 14-line backlit LCD display provides easy-to-understand details concerning up to 1.000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. Four password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 ac- cess without a password to management and emergency personnel. Standard Features Supports up to 250 Signature Series intelligent devices Combines the Signature intelligent releasing module with Signa- ture multisensor detectors for reliable suppression Failsafe mode ensures uncompromised reliability Class A (Style 7) or Class B (Style 4) wiring options Capacity for eight serial annunciators Four built-in system relays Optional dualline dialer supports Contact ID and 4/2 formats Three methods of programming: QuickStart "auto-learn," front panel and personal computer (PC) Supports optional barcode scanner for direct device data entry Optional bank of 30 front panel switches with dual LEDs Up to 20 adjustable pre-alarm settings for Signature smoke detectors Wallboxes available in red or gray with optional trim ring for semi-flush mounting. Large 14-line 1224 character) backlit LCD display Four password levels, plus priority access keyswitch Message routing by event type or by individual message Alarm sensitivity by time of day or manual selection 1,000 event history buffer, plus alarm history counter 6 amp Power Supply, 4.75 amps available for external use Envoy graphics compatible Compare utility identifies system changes and simplifies testing S Intelligent Single Loop Life Safety Control Panel QS1 77 : )•---- L_ Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 1 of 8 Application Thanks to its flexibility and simple setup and operation, QS1 is ideal for new installations in schools, apartment buildings, hospitals, of- fice buildings, and retail facilities. The benefits brought by QS1 to retrofit applications underscores the true potential of this powerful system. As an intelligent panel, QS1 supports Signature Series devices, which can use existing wiring in most retrofit applications. This makes upgrading from a conven- tional system to analog control a simple operation with minimal disruption to normal operations at the site. Which Quickstart Pansi is right for you' QS1 -QS4 Signature Series devices supported 0 1 x 250 4 x 250 Conventional class B circuits supported 3 x 16 0 3 x 16 Conventional class A circuits supported 5 x 8 0 5 x 8 LCD display (lines x characters) 4 x 20 14 x 16 14 x 16 Optional Zone Switch/LEDs on front panel 2 x 30 1x30 2 x 30 Option card spaces 5 or 12 1 Sot 12 Dimensions o 0 0 18 (45.72 cm) 0 * 0 For more information, see Data Sheet ._85005 -0112 85005 -0113 85005-0114 (36.2 cm) CPU / LCD Display The QS1 front panel display provides 14 lines by 16 characters of Mounting text detailing event, device, diagnostic, and programming infor- 2.2" motion. Its large backlit LCD screen is easy to read and always (5.6 Cm) provides at-a-glance indication of the system's state of operation. 8" 1(6.8 2 6 cm)*H I 4.88 (12.4 cm) The CPU/Display Unit houses the CPU cord and mounting space for one optional LED/Switch card .1 Optional Vandal- I A sOO - Resistant Door .•. I- Oti L R1'1Tli5_ I PDi CSI 5515 - Dais. snssr -i Ross I I s sss s Q 155 I I OI OI D5'I 'f'R I, Tso t 1 Semi flush mount- 0 L SF TSSL ROS a W' II (427m ing requires an LJ Wail • optional trim ring, J1 which adds Y4" Semi-flush Surface to all sides of the Mounting panel. Mounting Display with two alarms shown Specifications Control Panel Standby Current: 199 mA Alarm Current: 235 mA Remote annunciator Standby Current 154 mA (Full control versions) Alarm Current: 166 mA SRA Series Standby Current: 70 mA Alarm Current: 90 mA Operating Temperature: 32-120°F (0-49 °C) environment Humidity: 93 %RH, non-condensing Failsafe Mode If the CPU loses communication with other circuit cords, the power supply card continues to monitor the system for any alarm events. If on alarm occurs on any device or circuit during a communica- tions failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. Data Sheet 85005-0113 Issue 6 Not to be used for instaflation purposes. Page 2 of 8 Mounting .,._ Field wiring Electrical box Class B Wiring I 0 CH2(-)OUT 0 CH2(-)OUT 0 CH2-)OUT 0 CH2(D)OUT 0 CH2(-)IN I CH2(-)IN I 0 CH2I+IIN I 0 CH2I.IIN 9 CHI(-)OUT 0 CHI(-)OUT PSG 1 I 0 CHI(D)OUT CHIIDIOUT 0 CHl-lIN I R5485- 0 0 cH1(-)]N RS485 0 CHI(D)IN I CH1(D)IN 9 +24VOC OUT 0 D24vDC OUT LISTED 24 VDC SUPPLY 9_CT 0 COMMON OUT 0 o 24 VDC 0 0 0 D24VDC IN 24 VDC-O Ø~ !7- OCOMMONIN ? ?EARTHGND S Class A Wiring X485 CH2 CH2 RA RA CHI CHI S Remote Annunciators QS1 supports up to eight remote annunciators, which provide mirrored or customized annunciation of front panel messages and status indicators. Two models are available: The QSA Series, and the SRA Series. QS1 Annunciator I[i19rifl QS1 remote annunciators connect directly to the PS6 Power Supply Card or an external 24 Vdc filtered supply. They are available with wailboxes for flush or surface mounting. Annuncia- tors are available with one annuncia- tor option space for a display card with 30 dedicated switches and LEDs. See the Ordering Table for more information. Class B Wiring 24VDC RISER> I PS6TB1-13> I PS6TB1-14 :FYII1 i SRA Annunci Ifor The QuickStart SRA Remote Annunciator is a single-loop standalone unit that can be powered by the control panel or by an approved power supply. Annunciators support Class A or Class B connection to the sys- tem RS-485 data line, but do not provide ground fault isolation. The SRA annunciator includes an RJ-12 modular jack to allow sys- tem database downloads from a laptop computer. Connection requires a programming cable (model number PROGCABLE-1, ordered separately). Annun- ciators are mounted to North American 2-gang or 4-inch square electrical boxes. +—+-- CH2 CH1 Dimensions Model -- Height Width Depth QSA-1-S 7.6'(19.46 cm) 14.25"(36.20 cm) 2.9"(7.3 cm) QSA-1-F (rough in) 6.56'116.66 cm) 13.25"(33.66 cm) 2.1"(5.33 cm) QSA-1-F (finished) 7.8"(19.81 cm) 14.42'(36.63 cm) 1.38"(3.49 cm) Rough-in dimensions reflect the size of the cabinet where it enters the wall. Finished dimensions reflect the size of the cabinet that protrudes from the wall. XGD Graphics Driver Card The XGD Graphics Driver Card is an interface device that connects a QuickStart annunciator to an Envoy Graphic Annunciator. The XGD provides the electronics required to support 24 LEDs and 12 switches on the Envoy display panel. Multiple XGD cards can be chained together in one graphic annunciator cabinet to control larger displays. The QuickStart SRA Series annunciators can support a maximum of six XGD cards. Class A Wiring I I I I I Annunciator I ) I -------------Annunciator 9 CH2(-)OUT I 0 CH2(-)OUT 0 CH2(D)OUT I 0 I2l;11N I 0 CH2( )IN I I CHI(D)OUT I 0 CHI (-)IN I OCH1(+)IN NT-A 9 CH2(*)OUT RS-485 CARD __ I I I I 0 CH2(-AN 0 CH2(+)IN 9CH1(-lONT I I I I I I II I I I I CH2- CH2 * CHI- 0 CH2* 0 I CH1I*)OUT I CHI(-)IN CHI(*)IN I I I I I I LISTED 24 C SUPPLY 24 VOC 0 24VOC- 0 9_*24 OUT 0 24C OUT I O COMMON OUT I I 0*24VDIN COMMON IN EARLLT .Ii 9COMMONOUT I 0 *24V0C IN COMMON IN _T_° I _____________ I I I Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 3 of 8 Operation Indicators Text display and 1 controls: Displays system messages, status information, & and programming menus. Arrow buttons move the display cursor. Alarm LED: Indicates a fire or life threatening emergency. Supervisory LED: Indicates an off-normal condition with the fire suppression system or related equipment. Disable/Test LED: Indicates part of the system is disabled or be- ing tested. Disabled components also signal a system trouble. Monitor LED: Indicates the operation of an ancillary system function (door closures, fan pressure switches). Trouble LED: Indicates an off-normal condition or wiring fault that compromises the integrity of the system. Ground Fault LED: Indicates a ground fault in the system wir- ing. Ground faults also signal a system trouble. CPU Foil LED: Indicates an unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. Power LED: Indicates the panel has power. Help button: Provides additional information about the device selected on the display. Status button: Displays the Status Menu from which you can identify active or disabled points in the system. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. (Q15 16 1 18 Controls Reset button: Allows devices or zones in alarm or trouble to restore to their standby condition. The LED 7 - indicates that the U0 Q9 panel is resetting. Alarm Silence button: Turns active notification appliances off depending on panel programming. Pressing Alarm Silence a second time turns them bock on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill Mode. Menu button: Displays the operator menus. Delete button: Returns to the previous menu or backspaces the cursor. Enter button: Press the Enter button to accept information or continue to the next item. Numeric keypad: Numbered buttons for entering values and making menu selections. Barcode scanner jack: Input for optional barcode scanner. Priority Access keyswitch: Enables control functions reserved for access level 2 and above without requiring a password. Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 4 of 8 Class B Signature Data Circuit 24 Vft Horn and Strobe Synchronization with Audible Silence ccis Signature Fire Circuit (1 pr.) Damper Horn and Strobe Control 2 pr) S Class B Notification Appliance Circuit with Genesis Signals and Signal Master for " Independent Horn and Strobe Control and Synchronization over two conductors. 2nd Floor S .@..-.I '?' Critical Process Monitoring - with Control Wateritow Switch - Sprinkler Supervisory r LSwitch Elevator - Capture CR1 Class A Notification Appliance Circuit Typical Wiring RM UM I T T:!.E.. Class A Fire Signature Data Damper Class A Signature Data Circuit Class A Notification Appliance Circuit with Genesis Signals and Signal Master for Independent Horn and Strobe Control and Synchronization over two conductors. 2nd Floor Class gNo fition CC1 anceCircuit \ I LEGEND I Enhanced Integrity End-of-Line tJ Horn-Strobe Resistor Genesis tj] Programmable I,J Horn-Strobe I/O Module No Genesis Fu—ml Universal U Signal Master I/O Module 2 Smoke Dual Circuit Detector Input Module 2-Wire M Control Relay €t) Smoke Detector Module Smoke Detector M Signal 'hrrfl' with Relay Base Module 5' Smoke Detector Signal Module '.V with Isolator Base (synchronization) Manual [] Riser Monitor LU Pull Station Module Junction R1 Monitor Module Box More wiring suggestions can be found in the QSI Fire Alarm Control Panel Installa- tion, Operation, and Maintenance Manual, P/N 3100184. z.v Critical Process . Watertlow, . • Monitoring F-- CT2 Switch Sprinkler Supervisory - Switch CR Si G Capture Notification Appliance Circuit: C Horn and Strobe Synchronization with Audible Silence QS1 Panel S Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 5 of 8 Standard Components and Option Cards QS1 panels come standard with a CPU/Display Unit an SLIC Signature Loop Controller, and a P56 Power Supply (see ordering information for details). Available QS1 option cards provide dialing capability or extra relays for ancillary control. Quick-Lok option cards snap onto DIN mounting rails for fast, no-fuss installation. One op- tion card space is available. --P Cabinet with option C / and batteries in / PS6 Power Supply Card .- -I.- - 9W Standard Component Description The PS6 provides primary dc power to all the circuit cards installed in the cabinet. There are four 24 Vdc power output circuits - three for powering auxiliary applications, and one for powering four-wire smoke detectors - and a charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. Wiring *00104133 CON 000 CON - T132 9L IllI 04- I0ø0000®00ø0ø 00 ®øITB1 08 OX CON * - * - NO C NC C NO C 00 C NO RELAYS 001032 804.533004.504 SOME 05485 03333 MCOO TO CCC P018 Relay 1: Form C. Contacts change position when the control panel processes on alarm signal and remain changed until all active alarm inputs restore and the control panel resets. Relay 2: Form A. Contacts change position when the panel processes a supervisory signal and remains changed until all active supervisory inputs restore. Relay 3: Form A. Contacts change position when the panel loses power or processes a trouble signal and remains changed until power returns or the trouble clears. Relay 4: Form A. Relay closes and opens according to panel programming. Smoke/Accessory Power: Jumper setting determines if the 24 Vdc is constant or resettable. - *00 SLIC Signature Loop Intelligent Controller Specifications Main supply circuit AC input: 115 or 230 vac, 50/60 Hertz DC input: 24 Vdc batteries Charge current: 2 amps Battery charging circuit Charge capacity: 40 amp hours luLl 30 amp hours IULCI Smoke/Accessory Voltage: 24 Vdc, regulated Current 250 mA power output circuit Wire se: 12 to 18 75 to 2.5 mml Auxiliary power output Quantity: 3 Voltage: 24 vdc full wave rectified circuits Current: 1.5 amps each Sty: Form C Common alarm relay Contact rating: 1 amp Wire size: 12 to 18 AWG 10.75 to 2.5 mm') Trouble, Supervisory Style: Form A IN/Ol and programmable Contact rating: 1 amp relays Wire size: 12 to 18 AWG 10.75 to 2.5 mm') Operating environment Temperature: 32 - 1200 F 10- 490 Cl Humidity: 93 %RH, non-condensing Current requirements Standby current: 72 mA Alarm current 96 mA Standard Component Description The SLIC provides one Class A or Class B data circuit (loop) for connecting Signature Series detectors and modules. The SLIC also provides two programmable Class A or Class B notifica- tion appliance circuits (NACs) for connecting polarized 24 Vdc notification appliances such as horns and strobes. QS1 supports one SLIC. Wiring Class Class OUT IN LOOP 4r1 '4r_i AC A- B. B-. COIl IEOIl I ØØ®ØØ®Ø®ITB2 I I II I II II 5 I I I I ION II Il 00 00000ØJTB1 B. B- AC A- Bo B-. AO A- NACI NAC2 Class 11 B2 Signaling Line Circuit and NACs are super- vised and power- limited. Specifications Configuration: Class B (Style 41 or Class A IStyle 71 Signaling line Capacity: 125 Signature detectors circuit 125 Signature modules Wire size: 18 to 12 AWG (0.75 to 2.5 mm) Circuit resistance: 65 ohms Circuit capacitance: 0.3 1jf Configuration: class B or class A Notification Output voltage: 24 vdc, nominal appliance Output current: 2.0 A at 24 Vdc for #1 circuits #1 and 0.8 A at 24 Vdc for #2 and #2 Wire size: 18 to 12 AWG (0.75 to 2.5 mm2) End of line resistor: 10k ohms, ½W NAC power Voltage: 24 Vdc, nominal input circuit Wire size: 18 to 12 AWG 10.75 to 2.5 mm) Operating Temperature: 32 - 1200 F 10 - 49° Cl environment Humidity: 93 %RH. non-condensing Current Standby current: 33 mA requirements Alarm Current: 57 mA (Both NACs on) Card spaces Requires one card space. Data Sheet 85005-0113 issue 6 Not to be used for installation purposes. Page 6 of 8 Description The NT-A, which includes the X485/ RS-485 card and QS-232/UART port, provides one Class A serial remote an- nunciator bus for connecting remote annunciator panels. Control panels require the X485 card and QS-232 port, which also serves as a laptop or printer port. The X485 occupies one card space on the chassis rail. The OS- 232 port plugs into the panel CPU. Wiring CH2 CH1 -, S SL-30-'1, SL20L5S, SL30L LED/Switch Cards Description - The SL30 and SL30-1 provide thirty circuits for -- zone annunciation. Each circuit comprises two LEDs and a push button switch. The SL30 push button switches are numbered from 1 to 30 and the SL30-1 push button switches are numbered from 31 to 60. The SL20L5S provides 20 cir- ,eb nbfaoa cuits for point annunciation and five circuits for -- I custom control functions. The SL30L provides S 30 circuits for point annunciation. SL20L5S and SL30L circuits are labeled using inserts provided with the cards. - - Option Card DLD Dialer Description Specifications The DLD is a ULl/ULC listed dual line Digital Alarm Communicating Operating Temperature: 32 - 120 F 10-49 C) Transmitter (DACT). It provides two phone line connections for send- environment Humidity: 93% RH, non-condensing ing system messages to a compatible Digital Alarm Communicator Standby: 13 mA Receiver. The OLD supports 4/2 and Contact ID formats. It occupies Current Alarm: 20 mA one card space on the chassis rail. requirements Dialing: 26 mA PR MIJRGI OR RING Two loop start lines on switched telephone network. Wiring - TB1 Phone Lines Pulse or DTMF dialing. TIP Wall Connector RJ31X/CA31A equiv. or RJ38X/CA38A equiv. Communications Contact ID (SIA DC-05),4/2 (SlA DC-02 P3). PHONE LM fi Protocol t Programming Via QuickStart, Front Panel or PC. fl4!L0EI2 Communications Communications Canada CS-03FCC,CFR 47 Parts Compliance 15 and 68, NFPA 72. ULI 864, ULC S527-M87 Signals can be transmitted to either or both of two S-4 PER0VTED Receivers receivers. 0 0 0000 0TB Z Telephone #s Two 24-digit numbers per receiver. T1RNG T1wG IN wG11G Card spaces Requires one card space. LINE I UNE2 Optidi Card 1ZR8Rè)ayCard Description ---- Specifications The ZR8 provides eight dry-contact relays that T131 Style: Form A (Nb) or Form B IN/Cl (jumper configurable) can be independently configured as Form A or ________ Output relays Contact rating: 1 amp © 30 Vdc resistive. Form B relays. It occupies one card space on the Wire size: 18 to 12 AWG (0.75 to 2.5 mm') chassis rail. Operating Temperature: 32 - 1200 F (0- 490 Cl ______ environment Humidity: 93 %Rft non-condensing Wiring ORE- +R6- +R7- +R8- Current Standby current: 11 mA 0 00000 requirements Alarm current: 18 ma per active relay \( Card spaces Requires one card space. 100000000T _________ 182 X 485 CIassARS 485 Card andQS 232 Port pion crr s Specifications Wire size 12 to 18 AWG (0.75 to 2.5 mm') twisted pair (6 twists per foot minimum) Circuit resistance 100 Ohms Circuit capacitance 0.4 iF Operating Temperature: 32 - 1200 F 10- 490 Cl environment Humidity: 93 %RH, noncondensing Current Standby: 60 mA requirements Alarm: 60 mA Card Spaces Requires one space for the NT-A Option Cords Specifications Temperature: 32 - 120°F 0-49° Cl Operating environment Humidity: 93% RH, non-condensing Current requirements Standby: imA Alarm: 075 mA per active LED Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 7 of 8 GE Ordering Information S .Part ecuri Dt.sLri ptiOfl Ship wt. Y Number lb (kg) Basic Package - Enclosure, SLIC, Power Supply, CPU and Display... U.S. Q51-1-G-1 Single loop system. 1 option card space. Gray enclosure, 115v transformer. 17.0 (7.71) 1888-378-2329 QS1-1-R-1 Single Loop System. 1 option card space. Red enclosure, 115v transformer. 17.0 17.711 F 866-503-3996 Note: SUC Card includes One Signature Loop Intelligent Controller for up to 250 devices and one Class A or two Class B NACs. Canada 15193762430 EnclosureAccessorit F 519 376 7258 QS4VR Vandal-resistant cabinet door. gray 3.0111.361 Asia QS-i-VR-R Vandal-resistant cabinet door, red 3.011.361 1852 2907 8108 TRIM-1 Trim Kit - gray 5.012.271 F 852 2142 5063 TRIM-111 Trim Kit - red 5.012.271 Option Cords - DLD Dual Line Dialer. Supports 4/2 and Contact ID formats. 1.0 10.451 ZR8 Relay Card. 8 programmable Form A contacts. 1.0(0.45) Display Options SL30 Annunciator module. Numbered ito 30. Two LEDs and one switch per zone. 1.010.451 SL20L5S Annunciator module. 20 circuits for point or zone annunciation, 5 1010451 circuits for custom functions. Circuits labeled with insert card. SL30L Annunciator module. 30 circuits. Circuits labeled with insert card. 1.0(0.45) QS1-CPU-1 Single Loop CPU/Display, one annunciator option space -- 4.0 (1.81) EST-SRA1 Intelligent/Conventional CPU/Display with integrated LCD and control 4.0 (1.811 switches. 4 square box mount. RS-485 option card. Required for Class A remote annunciation. Includes 1010451 NT - A UART card. QS-232 UART option card. Plugs into CPU. Required for PC Programming / 101045) printerport. Included in NT-A package Remote Annunciator Cabinets (c/w Interface Assembly; Require CPU/Display)... QSA-1-S Surface Remote Annunciator Cabinet. Space for one SL3O display card. 4.0)1.81) QSA-i-F Flush Remote Annunciator Cabinet. Space for one SL30 display card. 4.0)1.81) Surface Remote Annunciator Cabinet. Vandal Resistant. Space for one 40)181) SA-1-S-VR SL30 display card. SA-1-F-VR Flush Remote Annunciator Cabinet. Vandal Resistant. Space for one 4.0(1.81) SL30 disolav cord. Programming Tool OS-CU QuickStart Panel Configuration Utility. 1.0110.451 OS-Scan QuickStort scanner and programming guide. 2.0)0.91) Progcable-1 Scanner port upload/download cable 1.010.451 260097 Programming cable (PC to QSC, 051, QS4) 1.010.451 Accessories PT- is System Printer - Desktop Style 14.016.351 BC-1(R) Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 19.981 MFC-A MultiFunctionCabinet. 7.0(3.1) 10133A RS-232 Isolator Module. 3.011.361 RPM Reverse Polarity Module. 3.011.361 2-CTM City Tie Module. - 1.0(0.45) API-8/232ME Alphanumeric Pager Interface. 11.0(5.0) BPS6A 6.5 Amp Booster Power Supply, 110 V 13.0(5.9) BPS10A 10 Amp Booster Power Supply, 110 V 13.0 15.91 CDR3 PSNI Coder Module 1.0(0.45) Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 www.gesecurity.com © 2006 General Electric Company All Rights Reserved QuickStart and Signature Series ore Trademarks of GE Security. Ordering options (Apply to basic packages and CPU/displays only) Languages No suffix = American English SP = Spanish 1230v or 115v1 PG = Portuguese 1230v only) FR = French Canadian (120v only) Power Supplies 1 = 115v transformer 2 = 230v transformer Colors G = Grey enclosure (230v or 115v) R = Red enclosure (115v only) Examples QS1-1-G-2-SP = 051 basic package with one option card space, grey enclosure, 230v transformer, Span- ish language. QS1-CPU-FR = 051 CPU/display, French Canadian. imagination at work Data Sheet 85005-0113 Issue 6 Not to be used for installation purposes. Page 8 of 8 S LISTING No. CATEGORY: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-1657:207 Page 1 of I Control Unit (Non High-Rise) LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941)739-4358 FAX (941) 308-8123 DESIGN: Models QSC, -QS1 and -QS4 fire alarm control units, followed by —1 or —2 followed by -BR, -SP, - FR, -PG or no suffix. Local, local with shunt, auxiliary, remote station, releasing service or central station. Power limited. Non-coded, coded, shunt, reverse polarity, DAd, manual, automatic waterfiow, and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System Components: QSC, QSI, QS4 7200001-01, -02; 7200004-01, -02 7200005-01, —02 PS6 ZB16-4 ZA8-2 DLD ZR8 NT-A QS232, 232 SL3O SL-30-1 SLIC QS-1-VR, -R, QS-2-VR, -R SL3OL SL2OLSS Control Units Enclosures Enclosures Power supply Class B zone card Class A zone card Dialer (DACT) card Relay card Class A, RS485 communications card Port for download or printer functions LED/Switch card with switch 1-30 LED/Switch card with switch 31-60 Signature expansion loop card. Vandal resistant doors LED Cards 30 Zones LED/Switch Cards 25 Zones RATING: INSTALLATION: MARKING: APPROVAL: NOTE: 120/220 VAC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to listee's Installation Instruction Manual for details. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Formerly 7165-1591:207 and 7165-1388:237 08-1 7-05KK I.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ... .'. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-1657:206 Page 1 of I CATEGORY: Annunciators LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models QSA remote annunciator cabinets, followed by —1 or —2, followed by —F or —S. Stands for I or 2 zone, Surface or Flush mount, which includes the RAI, remote interface subassembly. Models QSA key locked annunciator enclosures, followed by-1 or —2, followed by —F or - 5, followed by —yR. Stands for I or 2 zone, Surface or Flush mount and VR stands for key locked, which includes the RAI, remote interface subassembly. Models EST-SRA1 single loop and EST-SRA4 multiple loop remote annunciators. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. S MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as annunciators for use with listee's separately listed Models QSC, -QSI and -Q54 (CSFM Listing No. 7165-1657:207) fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7120-1591:206 and 7120-1388:236 08-17-05 VL.• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. S Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers .. II INITIATING DEVICES S S 650 Opper Street • Escondido, CA 92029 9 Tel (760) 746-1003 • Fax (760) 746-4619 • C 1048504 , AppIicoton Notes Aooiloble Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 1 of 4 GE EST Fire & Life Safety S Security Intelligent Initiating Devices S Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sensing ele- ment and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated. The microprocessor in each detector provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detec- tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being rein- stalled (after cleaning etc.) in a different location from where it was originally. Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communica- tions fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards S Intelligent Photoelectric Smoke Detector ," SIGA-PS Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep..They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. I I J0.8'(2omm) 2.0'(51 mm) = I I 4.4' (112 mm) - Tamper-Resist Lever Arm - Break off to disable - . 1J (Located on Bose) - Access Slot for Tamper-Resist Mechanism : .--.. ..--I-.-.- Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity measure- ments which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent an the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detector operation should be planned to meet the requirements of the Au- thority Having Jurisdiction lAHJl. Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or an the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31h inch or 4 inch octagon boxes, 1112 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-1B4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. I rrl~` SIGA-AB413 SIGA-SB SibA-18 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA- RB can be operated as a control relay if programmed to do so at the control panel (E5T3 V.2 only). The relay base does not support the SIGA-LED Remote LED, Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SlGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-I134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop con- troller. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 2 of 4 Normally- Normally- DA1 DATA IN (+) From Signature Controller or Previous Device Term Description 1 Not Used 2 DATA IN/OUT 3 DATA INi-i 4 Not Used 5 Not Used 6 DATA OUT i-i 7 Not Used OUT(-) Volume sell Default = High volu Cut for low volu 24 Vdc In From power Supply or previous base Data In From Signature controller or previous device tone setting Default = Temporal pattern u1 for steady tone - To configure output volume or tsne, cut the circuit board as Shown. 24 Vdc out To next base or EOL relay Data out To next Signature device DATA OUT (+) To Next Device Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. S GE Security recommends that this detector be installed according to latest recognized edition of notional and local fire alarm codes. SlGA-HRS and SIGA- HFS Rate-of-Rise/;SIGA-PHS SIGA-IPHS TestFire SIGA-IS Ion SIGA-PS Photo Fb<ed Temp. Photo Heat 30 Ion/Photo/Heat4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG 11.5mm21, and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG 10.75mm21 are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SlGA-RB4 Term Description 1 Not used 2 DATA IN/OUT 1+1 3 Not used 4 DATA IN I-i 5 Remote LED I-) 6 Remote LED 1~1 7 Not used 8 DATA OUT I-i — 1=' 13 .) I Ir.xsiuiro DATA IN (+) DATA OUT (+) From Signature controller To Next Device or Previous Device DAT . S.-, From Sgnoture controller or Previous Device Term Description 1 Normally Open 2 DATA IN/OUT 1+1 3 common 4 DATA IN i-I S Not Used 6 Normally-closed 7 DATA OUT CONTACT RATING 1.0 Amp @30 VDC OUT (-) (Pilot Duty) OUT (+) To Next Device Remote LED (SIGA-LED) Max. Resistance per Wire - + Must NOT Exceed 100 Isolator Detector Base, SIGA-113, SIGA-1134 Audible Detector Base, SlGA-AB4G Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 3 of 4 Specifications Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Air Velocity Range: 0 to 5,000 ft/mm 10 to 25.39 m/s): Humidity: 0 to 93% Environment RH, Non-Condensing Operating Temp: 32°F to 120°F 10°C to 490Cl: Stor- age Temp: -4°F to 140°F l-20°Cto 60°Cl Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot User Selected Alarm Most Sensitive: 1.0%/ft.: More Sensitive: 2.0%/ft.: Normal: 2.5%/ft.; Less Sensitivity Settings Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. U.S. 1888-378-2329 F 866-503-3996 Canada 15193762430 F 519 376 7258 Asia 1852 2907 8108 F 852 2142 5063 Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Australia T 613 9259 4700 Operating Voltage 15.2 to 1995 Vdc (19 Vdc nominal) F 61 392594799 Operating Current Quiescent: 45pA © 19 V; Alarm: 45pA © 19 V Emergency Stand-alone Alarm Made: 18mA Pulse Current: 100 pA 1100 msecl: During Communi- Europe cation: 9 mA max. T 32 2 725 11 20 32 2 72186 13 Construction & Finish High Impact Engineering Polymer - WhiteF Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator Base, SIGA- Latin America Bases AB4, SIGA-AB4G Audible Bases 1305 593 4301 LED Operation On-board Green LED - Flashes when polled: On-board Red LED - Flashes F 305 593 4300 when in alarm Both LEDs - Glow steady when in alarm (stand-alone) wwwgesecurity.com . Compatible Remote Red LED (model_SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop Controller © 2006 General Electric company Address Requirements Uses one Device Address All Rights Reserved Agency Listings UL, ULC, MEA, CSFM UL_ Listed _Spacing 30_ft Signature Series is a Trademark of GE Security. Ordering Information Lotulog Dcription ..hip t Nurnbr . lbs (kl SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.51.231 -. -- Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt - SIGA-RB Detector Mounting Base w/Relay SlGA-RB44-inch Detector Mounting Base w/Relay,c/wSIGA-TS4 Trim Skirt 0.21.091 SIGA-113 Detector Mounting Base w/Fault Isolator SlGA-1134 4-inch Detector Mounting Base w/ Fault Isolator. c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3(0.15) SIGA-TS4 Trim Skirt supplied with 4-inch bases) .11.04) imagination at work Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 4 of 4 GE EST Fire & Life Safety S Security Intelligent Initiating Devices Overview Signature Series Model SIGA-HFS and SIGA-HRS Intelligent Heat Detectors gather analog information from their fixed temperature and/or rate-of-rise heat sensing elements and converts it into dig- ital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital fil- ters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Lag, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Opera- tion Guide for details. 70 foot (21.3 meter) spacing 15° F (9° Wmin rate-of-rise/135° F (57°C) ft. and 135° F 157 ° C) fixed temperature type Intelligent detector c/w integral microprocessor Non-volatile memory Automatic device mapping Electronic addressing Identification of defective detectors Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Intelligent Heat Detectors SIGA-HFS & SIGA-HRS @1 Applicatios Notes Aesiloble Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 1 of 6 Installation Spacing - The SlGA-HFS (fixed temperature) and the SIGA-H RS fixed temperature/rate-of-rise combination) intelligent heat detectors are rated for installation at up to 70 foot (21.3 meter) spacing. These detectors may be installed in rooms with ambient temperatures up to 100°F (380C). Status LEDs - Twin LEDs are visible from any direction. A flashing GREEN LED shows normal system polling from the loop controller. A flashing RED LED means the detector is in alarm state. Both LEDs on steady shows alarm state - stand-alone mode. Normal GREEN LED activity is not distracting to building occupants, but can be quickly spotted by a maintenance technician. Quality and Reliability - GE Security detectors are manufactured in North America to strict international ISO 9001 standards. All electronics utilize surface mount technology (SMT) for smaller size and greater immunity to RF noise. A conformal coating is used for humidity and corrosion resistance. All critical contacts are gold plated. Installation Signature Series detectors mount to North American 1-gong boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gong boxes with 60.3 mm fixing centers. J 0.8'(20 mm) 2.0'(51 mm) II Ii 4.4'(112 mm) Tamper-Resisf Lever Arm - Break off to disable - (Located on Base) Access Slot for Tamper-Resist Mechanism Signature Series Overview Self-diagnostics and History Log - Each Signature Series detec- tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. This information is accessible for review any time at the control panel, PC, or by using the SlGA-PRO Signature Program/Service Tool. In the unlikely event that an unwanted alarm does take place, the control panels history file can be called up to help isolate the prob- lem and prevent it from happening again. Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. This mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. The history log for the detector remains relevant and intact regardless of its new location. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing wire branches (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communica- tions fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Each detector on the circuit continues to collect and analyze information from its surroundings. Both the SlGA-HRS and SIGA-HFS detectors alarm if the ambient temperature increases to 135°F (57°C) or for the SIGA-HRS only, the temperature increases at a rate exceeding 15°F 1900/minute. If the detector is mounted to a relay base, the relay operates. Similarly, if it is mounted to on audible base, the on-board horn sounds. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the control panel when it has something new to report. This provides very fast control panel response time and allows a lower baud rate (speed) to be used for communication on the circuit. The lower baud rate offers several advantages including: - less sensitivity to circuit wire characteristics - less sensitivity to noise glitches on the cable - less emitted noise from the data wiring - twisted or shielded wiring is not required Electronic Addressing - The loop controller electronically addresses each detector, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each detector has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the circuit and assigns a "soft address to that device's serial number. If desired, detectors can be addressed using the SIGA-PRO Signature Program/Service Tool. Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 2 of 6 Remote LED (SIGA-LED) Max, Resistance per Wire Must NOT Exceed IOn Term Description 1 Not Used 2 DATA IN/OUT 1~1 3 Not Used 4 - ) DATAINI 4 Remote LED C-) 5 Remote LED 1+1 6 Not Used 7 DATA OUT Isolator Detector Base, SIGA-IB, SIGA-1B4 OUT (+) To Next DevIce DA1 DATr IN 1.1') From Signature Controller or Previous Device s Description Not Used DATA IN/OUT 1+1 DATA IN I-I Not Used Not Used DATA OUT I-I Not Used OUT(-) Application The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single S sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. Test Fire SIGA-IS Ion SIGA-PS Photo SlGA-HRS and SiGA- HFS Rate-of-Rise! Fixed Temp. SIGA-PHS Photo Heat 3D SIG A-IPHS Ion/Photo/Heat 40 Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2). and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Adk000 Relay Detector Base, SIGA-RB, SIGA-RB4 CAT DAT,- From Signature Controller or Previous Device Normally- Normally- IN (-) I '.. (-,n) fl V I DATA OUT (.) DATA IN (+) DATA OUT (+) From Signature Controller To Next Device or Previous Device Term Description 1 Normally-Open 2 DATA IN/OUTl+l 3 Common 4 DATAlNl - l S Not Used 6 Normally-Closed 7 DATAOUTI - l CONTACT RATING —] 1.0 Amp @30 VDC IPilot Duty) OUT (-) OUT (+) To Next Device Audible Detector Base, SIGA-AB4G Volume setting Tone setting Default = High volume Default = Temporal pattern Cut for tow volume aD (111 Cut for steady tone jiiwo w tone. cut the it board To configure output volume as Shown. 24 Vdc In II p. previous base To nest base or EOL relay From power supply or _________________________ 24 Vdc out Data In From Signature controller or Data out previous G.M.W. To next Signature device ic Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 3 of 6 Accessories All detector mounting bases have wiring terminals that are acces- sible from the 'room-side' after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11h inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SlGA-1134 mount to North American four inch square electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the 'mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. '•5 :' __ SIGA-AB4G SIGA-SB SI,-lB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SlGA-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SlGA-RB4 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relays position is supervised to ovoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V. 2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses on alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the some 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SlGA-113, SIGA-1134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - if the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop control- ler. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SlGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where heat cannot reach the detector. Heat from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it The heat sensor in this device only provides a source of informa- tion to supplement the information provided by photoelectric or ionization smoke detectors which may be located nearby. The heat detector by itself does NOT provide life safety protection. Under no circumstances should heat detectors be relied on as the sole means of fire protection. Compatibility The SIGA-HFS and SIGA-HRS detectors are compatible only with GE Security's Signature Loop Controller. Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 4 of 6 L 77, Fixed Temperature Fixed & Temperature! Rate-of-Rise Heat Sensing Element Alarm Point Alarms at 135°F (57°C) Ambient Alarms at 135°F 157°Cl Ambient or Temp. increase above 15°F (9°C) per mm. UL Listed Detector Spacing 70 feet (21.3 meters) center to center spacing Operating and Storage Environment Operating Temp: 32°F to 100°F (0°C to 38°C) Storage Temp: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH, Non-Condensing Operating voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Current Quiescent: 45pA © 19 V Alarm: 45pA © 19V Emergency Stand-alone Alarm Mode: 18mA Pulse Current 100 IJA (100 msec) Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases SIGA-SB Standard Base, SlGA-RB Relay Base, SlGA-IB Isolator Bose, SIGA-AB4, SIGA-AB4G Audible Bases LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm: Both LEDs - Glow steady when in alarm (stand-alone) Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one device address Agency Listings UL, ULC, MEA, CSFM S ca Specifications Nv~ Ordering Information CataIog Number Description Ship Wt Ibs(kg) SIGA-HFS Intelligent Fixed Temperature Heat Detector - UL/ULC Listed 0.5 (0.23) SlGA-HRS Intelligent Fixed Temperature/Rate-of-Rise Heat Detector - UIJULC Listed sries SIGA-SB Detector Mounting Base -- -- SIGA-5B4 4-inch Detector Mounting Bose c/w SIGA-TS Trim Skirt SIGA-RB Detector Mounting Bose w/Relay 02 1091 . SIGA-RB4 4-inch Detector Mounting Base /w Relay c/w SIGA-TS Trim Skirt SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-I134 4-inch Detector Mounting Base w/ Fault Isolator c/w SlGA-TS Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base 0.3 (0.15) SlGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 1.041 Data Sheet 85001-0243 Issue 6 Not to be used for installation purposes. Page 5 of 6 S U.S. 1 888-378-2329 F 866-503-3996 Canada 1 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 www.gesecurity.com © 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. imagination at work Nottobeused Data Sheet 85001-0243 Issue 6 for installation purposes. Page 6 of 6 * MEA 'atented SIGA-278 SIGA-270 SERIES Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 1 of 4 GE EST Fire & Life Safety S Security Intelligent Initiating Devices Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of GE Security's Signature Series system. The SlGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cost zinc and finished with red epoxy pow- der-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models (SlGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. GE Security's double action single stage SIGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance SIGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models SIGA-270 models are available for one or two stage alarm sys- tems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism, Break glass operation An up-front visible glass rod on the SIGA-270 discourages tam- pering. Intelligent device c/w integral microprocessor All decisions are made at the station allowing lower communica- tion speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. Non-volatile memory Permanently stores serial number, type of device, and job num- ber. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop controller regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (49 °Cl. Manual Pull Stations SIGA-270, SIGA-270P, SIGA-278 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or 'Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop con- troller when the station's pull lever is operated. The alarm condition is latched at the station. Compatibility Signature Series manual stations are compatible only with GE Secu- rity's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The SIGA-270 series are opened with a tool; the SIGA-278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Au- thority Having Jurisdiction (AHJI. Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller cata- log sheet for detailed wiring requirement specifications. Wiring Notes Zil Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW — of SIGA-278 2 0 TB2 7 • Red LED Gn LED (Maim/Active)2 Oee MOD 1 o 181 -. r DATA IN 1*)> DATA 01111.) DATA IN(-) > p DATA OUT(.) From signature Coniroler To Next Device or Previous Device Figure 4. Single Stage Systems 0 f DATA IN(v))- • DATA OUT 1 DATA IN(-) >- p. DATA OUT I-) From Signature Controller Y To Next Device or Previous Device A Figure 5. Two Stage Systems Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 2 of 4 REAR VIEW of SIGA-270P. SIGC-270PB Red LED (Jorm/Aclle) Green LED (Normat Compatible Electrical Box Cover 4 Release Screw Bock Plate @ Toggle Switch 0 L511 Glass Rod Release Lever ENT19-fil MEN Key-Latch Cover Release Glass Rod Compatible Electrical Box Back Plato Toggle Switch " Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 2112 inch (64 mm) deep 1-gang boxes . Two stage presignal l270Pl models require 11/2 inch (38 mm) deep 4-inch square boxes with 1-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model Cl-52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm21 wire size. GE Security recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system commission- ing. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SlGA-PRO Signature Program/Service Tool. Figure 1. SlGA-278 installation Figure 2. SIGA-270, SlGC-270F, SIGC-270B installation Cover Release Glass Rod Release Lever Figure 3 SlGA-270P, STGC-270P8 installation Data sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 3 of 4 [I Specifications HK 2IGA 270 SIGC 2 OF IGA 270P CatalogNurnber SIGC 2708 SlGC 270P8 SlGA-278 Description Single Action Single Action -Two Double Action - One Stage Stage lPresignall - -One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396pA Standby = 250pA Activated =LIOOpA Activated=6801JA ' Activated = 400pA - Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc 119 Vdc nominal) Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH On-board Green LED - Flashes when polled LED Operation On-board Red LED - Flashes w hen in alarm Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use With: Signature Loop Controller__________ Agency Listings UL ULC Incite 1), MEA, CSFM Note: SIGC-270F. SIGC-2708 and SIGC-270P8 are ULC listed only. Suffix "P indicates French markings. Suffix "B "indicates English/French biting ual markings. U.S. T 888-378-2329 F 866-503-3996 Canada 15193762430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F 32 2 72186 13 Latin America 1305 593 4301 F 305 593 4300 www.gesecurity.com © 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. Ordering information Catalog SHp V.'t. Numble r Description lbs (kg) SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SIGA-270P Two Stage IPresignall Fire Alarm Station, English Markings - UL/ULC Listed 10-5) SIGC-270PB Two Stage IPresignall Fire Alarm Station, French/English Markings - ULC Listed SIGA-278 Double Action (One Stage) Fire Alarm Station, English Markings - UL/ULC Listed Accessories 32997 GA Key w/Tag - for pre-signal station (CANADA ONLY) 276-K2 GA Key - for pre-signal station (USA ONLY) 27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY) 0.11.051 270-GLR 20 Glass Rods - for SIGA-270 series lUSA ONLY) 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 110.61 imagination at work Data Sheet 85001-0279 Issue 7 Not to be used for installation purposes. Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7272-1657:126 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SIGA-PS and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: 1. Model SIGA-PHS is not intended for use in lieu of a required heat detector. 2. Formerly 7272-1591:126 and 7272-1388:186 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7270-1657:125 Page 1 of 1 CATEGORY: Heat Detector LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Model SIGA-HFS and SIGA-HRS heat detectors. Model SIGA-HFS is a 1350F fixed temperature detector and Model SIGA-HRS is a 135°F fixed temperature and a 15°F/mm rate of rise detector. Refer to listee's data sheet for detailed model descriptions and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible bases (CSFM S Listing No. 7300-1657:120) and fire alarm control units. NOTE: Formerly 7270-1591:125 and 7270-1388:185 08-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:120 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Detector Bases. Refer to listee's data sheet for detailed product description and operational considerations. Base models are as follow: BASES 5963B, 5964 B/BR 6241 B-002, 6249B-001 6251, 6251B-001A, -001, -002, -003, -004, 6251B-100, -200, -R100, -R200 and 6251-2 Models 6251 B-001, -002, -003 and -004 suitable for releasing device service. P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047 SIGA-SB, -SB4, -RB, -RB4, -IB, -1134 and -AB4 S The -RB series are suitable for releasing device service. Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 08-15-05 4. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ... . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7150-1657:129 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SIGA-270, SIGA-270P, and SIGA-278 noncoded, intelligent manual pull stations. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. 0 NOTE: Formerly 7150-1591:129 and 7150-1388:194 08-15-05 h. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ... .. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 5 Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers . II, INPUT/OUTPUT DEVICES S 650 Opper Street 9 Escondido, CA 92029 9 Tel (760) 746-1003 • Fax (760) 746-4619 9 Cl0-#85046 ran EST Fire & Life Safety Security Intelligent Input/Output Overview The SIGA-CT1 Single Input Module and SIGA-CT2/SlGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personality code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configuration. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1 and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advan- tage of the modular flexibility and easy installation that character- izes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in GE Security enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the module through the loop controller. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop control- ler, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Non-volatile memory Permanently stores serial number, type of device, and job number. Stand-alone operation The module makes decisions and inputs an alarm from initiating devices connected to it even if the loop controller's polling interro- gation stops. (Function availability dependent upon control panel.) Ground fault detection by address Detects ground faults right down to the device level. Input Modules SIGA-M, SIGA-CT2 & SIGA-MCT2 Pt SIGA-MCT2 i . :24 El Us MEA Application Notes Available Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 1 of 4 S Signature Series Overview The Signature Series intelligent analog-addressable system from GE Security is an entire family of multi-sensor detectors and mount- ing bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four addi- tional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This informa- tion is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping -The Signature Data Controller (SDCl learns where each device's serial number address is installed rela- tive to other devices on the circuit. The SDC keeps a map of all Sig- nature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-tops), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1 and SlGA-CT2: modules mount to North American 21h inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm') wire size. SlGA-MCT2: mount the UIO motherboard inside a suitable GE Secu- rity enclosure with screws and washers provided. Plug the SlGA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm2) wire size. UIO Motherboard 6-32 Self-tapping screws - - Plug-in (UlO) >capuve Module screws 11tl 1 #6 FIat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two person- ality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1)- As- sign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Personality Code 2)- Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3)- Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4)- Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condi- tion is latched at the module. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 2 of 4 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. S Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. i..tting (Slue) Device rctht Wire SpeThcations__________________________ Maximum Allowable Wire Resistance 50 ohms 125 ohms per wire) per Circuit Maximum Allowable Wire Capacitance O.lpF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm') #16 AWG 11.00 mm') 4,000 ft (1,219 ml #14 AWG 1.50 mm') #12 AWG 11.50 mm') Typical N.O. Initiating Device Typical N.C. Initiating Device INPUT 1 INPUT 2 A AAstyie B (class B) Ti T82 •. . • 47 EOL UL/ULC Listed Style B (Class B) 6 5 7 . UL/ULC usted 471<0 EOL 47K0 EOL A A A uL/uLc Listed Red LED Green LED _____________ _____________ (Alarm/Active) © _ ___________ (Normal) Red LED Green LEO ( 4 3 2 1 (Alarm/Active) (Normal) TB1 TBlt _______________ _________ DATA IN I ________ DATA IN > DATA OUT I . {DATAlN(+) DATA OUT(-) } { DATA IN (-) I DATA OUT (+)} DATA OUT (-) From signature Controller i To Next Device From Signature Controller Next Device er or Previous Device or Previous Device A A SlGA-CT1 SIGA-CT2 Typii NO inWUn9 Dovlo NOTES UUULC LJeod ULAJLC ue02 47KflEOL 1 4r525 EOI. Maximum 25 Ohm resistance per wire. Maximum #12 AWG 2.5 mm') wire; Minimum #18 AWG 10.75 mm2l. Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @350 pA The SIGA-UIOGR and the SIGA-U102R do not come with T614. 123 4 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. : N. Data I sIOA4ACT2 Oth cvwt -,&d. rpft Data OW + Warnings & Cautions G,nLEDiNoWl This module will not operate without electrical power. As fires fre- RLW(A) 31 L7 quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. N000nnorNp.,w6 roqi,od SIGMCT2. Compatibility SIGAMCT2 The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Data Sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 3 of 4 GE Security Specifications SIL,A LIZ J SIGA MCTZ Description Single Input Module Dual Input Module Type Code 48 factory set) Four 49 (factory set) Four sub-types (personality sub-types (personality codes) are available codes) are available Address Requirements Uses One Module Ad- Uses Two Module Addresses dress Operating Current Standby = 250pA; , Standby = 396pA: Activated = 680(JA Activated =, Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21h inch (64 mm) deep one-gang U102R/6R/6 Mother- boxes and 1½ inch (38 mm) deep 4 inch square I board boxes with one-gang covers and SlGA-MP mounting plates Storage and Operating Operating Temperature: 32°F to 120°F 10°C to 49°Cl Storage Temperature: Environment -4°F to 140°F 1-20°C to 60°Cl; Humidity: Oto 93% RH LED Operation On-board Green LED - Flashes when polled: On-board Red LED - Flashes when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA. CSFM Ordering Information Lc1taIoJ 'ccrlption Ship t Number SIGA-CT1 Single Input Module - UL/ULC Listed 0.4(0.15) SIGA-C12 Dual Input Module - UL/ULC Listed 0.410.151 SIGA-MCT2 Dual Input Plug-in (UlO) Module - UL. ULC Listed 0.1(0.05) Related Equipment, 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White. 1-gang 1.0(0.6) SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) - Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 10.281 - Six Module Positions SlGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56)0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0)3.1) Mounting Plates SlGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 10.701 SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.510.231 SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 10.461 U.S. T 888-378-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia 1852 2907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F32 2 72186 13 Latin America T 305 593 4301 F 305 593 4300 www.gesecurity.com tO 2006 General Electric Company All Rights Reserved Signature Series is a Trademark of GE Security. SIGA-CT1 imagination at work Data sheet 85001-0241 Issue 6 Not to be used for installation purposes. Page 4 of 4 GE EST Fire & Life Safety S Security Intelligent In put/Output S Overview The SIGA-MM1 Monitor Module and SIGA-WTM Waterfiow/Tamper Module are part of GE Security's Signature Series system. They are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits llDC). The function of the SIGA-MM 1 and SIGA-WTM is determined by the factory loaded 'personality code". The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The microprocessor in each module provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Standard Features Monitor and waterfiow/tamper applications Includes Alarm with delayed latching (retard) for waterflow applications, Supervisory, and Monitor. Non-volatile memory Permanently stores serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each module transmits wiring information to the loop controller regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stares programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SlGA-PRO Signature Program/Service Tool. Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time. Less sensitive to line noise and circuit wir- ing properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (490C). Input Modules SIGA-MM1 & SIGA-WTM k et 85001-0297 Issue S Not to be used for installation purposes. Page 1 of 4 Application The duty performed by the SIGA-MM1 and SIGA-WTM is determined by their factory assigned sub-type code or "Personality Code'. SIGA-WTM NORMALLY-OPEN ALARM - DELAYED LATCHING (Fac- tory set Personality Code 2) - Assigned to one circuit. Configures circuit 1 for Class B normally-open Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. SIGA-WTM NORMALLY-OPEN ACTIVE - LATCHING (Factory set Personality Code 4) - Assigned to one circuit. Configures circuit 2 for Class B normally open dry contact Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the mod- ule. SIGA-MM1 NORMALLY-OPEN ACTIVE - NON-LATCHING (Factory set Personality Code 3) - Assigned to one circuit. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module.Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance pro- gram shows the current state of each module and other pertinent messages. Single modules may be turned off (de-activated) tempo- rarily, from the control panel. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction lAHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Availability of maintenance features is dependent on the fire alarm system used. nsta II ati on The SlGA-MM1 and SIGA-WTM modules mount to North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SlGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mm') wire size. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Personality codes are assigned by the factory. No user configura- tion is required for these modules. 00 701 Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes. Page 2 of 4 Typical N.O. Monitor Contact A AA Style B (Class B) TB2 Red LED (Alarm/Active) UL/ULC Listed 471(0 EOL Green LED (Normal) Typical Wiring The module will accept #18 AWG (0.75mm2), #16 11.0mm21, #14 AWG (1.50mm2), #12 AWG (2.50mm1 wire sizes. Note: Sizes #16 AWG 11.0mm2l and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Maximum Allowable Wire Resistance 50 ohms 125 ohms per wire) per circuit Maximum Allowable Wire Capacitance 0.1pF per circuit For Design Reference: Wire Size Maximum Distance to EOLR — S #18 AWG 10.75 mm') #16 AWG 11.00 mm') #14 AWG (1.50 mm') #12 AWG (1.50 mm') Typical N.C. Waterfiow Contact Typical Supervisory Contact INPUT 1 INPUT 2 I style B(ClassB) lB2r UL/iJLCUsted • UL/ 9d ed R LED Green LED (Am/Ace) : (Normal ) TB1FJ IXE I DATA IN ()> r I I I I DATA OUT (+)} { DATA IN (+)> 1. DATA IN (-) > DATA OUT (-) DATAIN(-) P _ From Signature Controller To Next Device From Signature Controller or Previous Device A or Previous Device 4,000 ft 11219 ml DATA OUT (+) DATA To Next Device Model SIGA-WTM Model SIGA-MM1 Notes Al Maximum 25 ohms resistance per wire. Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 10 Vdc © 350pA. 51 All wiring power limited and supervised. 61 This module will NOT support 2-wire smoke detectors. Data Sheet 85001-0297 issue 5 Not to be used for installation purposes. Page 3 of 4 S GE Security U.S. 1888-378-2329 F 866-503-3996 Canada T 519 376 2430 F 519 376 7258 Asia T 852 2907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 13227251120 F32272186 13 Latin America 13055934301 F 305 593 4300 v.ww.gesecurity.com © 2006 General Electric Company All Rights Reserved Specifications Catciloy Number SIGA MM1 SIGA WTM Description Monitor Module Waterflow/Tomper Module Type Code 48 (factory set 49 (factory set personality Code 3) personality code 24) Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250lJA: Standby = 396pA: Activated = 400pA Operating voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction & Finish High Impact Engineering Polymer one-gong front plate - White Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Agency Listings Use With Signature Loop Controller UL, ULC, CSFM, MEA Mounting North American 2-1/2 inch (64 mm) deep one-gang boxes and 1- 1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. Signature Series is a Trademark of GE Security. Ordering Information Catcion - Description Number SIGA-MM1 Monitor Module - UL/ULC Listed SIGA-WTM Waterfiow/Tamper Module - UL/ULC Listed Ship Vlt lbs lkc:l O.4l.i Accessories 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gong MFC-A Multifunction Fire Cabinet 7.0(3.1) - Red, supports Signature Module Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SlGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 10.461 imagination at work Data Sheet 85001-0297 Issue 5 Not to be used for installation purposes. Page 4 of 4 sIGA-McRx Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 1 of 6 MEA CS GE EST Fire & Life Safety Security Intelligent Input/Output Overview The Control Relay Module and the Polarity Reversal Relay Module are port of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The SlGA-CR/MCR Control Relay Module provides a Form "C" dry relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in the proper ON/OFF state. Upon com- mand from the loop controller, the SlGA-CR/MCR relay activates the normally open or normally-closed contact. The SlGA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of SIGA- AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (SIGA-CR and SIGA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (SIGA-MCR and SIGA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the mother- board. UIO assemblies may be mounted in GE Security enclosures. Standard Features Provides one no/nc contact (SlGA-CR/MCR) Form "C" dry relay contact can be used to control external appli- ances such as door closers, fans, dampers etc. Allows group operation of sounder bases The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower communica- tion speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. S Control Relay Modules SIGA-CR, SIGA-MCR, SIGA-CRR, SIGA-MCRR Installation SIGA-CR and SIGA-CRR: modules mount to North American 22/2 inch (64 mm) deep 1-gong boxes and 1112 inch (38 mm) deep 4 inch square boxes with 1-gong covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. 11 SIGA-MCR and SIGA-MCRR: mount the UlO motherboard inside a suitable GE Security enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). U 1 motherboard terminals are suited for #12 to #18 AWG 12.5 mm2 to 0.75 mm2) wire size. UIO Motherboard L 6-32 Self-tapping screws I Plig-in (UlO) Captive I Modul screws #6 Flat washers —Cabinet or electrical enclosure Application The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (SIGA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp © 24 Vdc; 0.5 amp © 120 Vac (or 220 Vac for non-UL applications). Personality Code 8 is assigned at the fac- tory. Na user configuration is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (SIGA- CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility The Signature Series modules are compatible only with GE Securi- ty's Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance pro- gram shows the current state of each module and other pertinent messages. Single modules may be turned off (deactivated) tempo- rarily, from the control panel. Availability of maintenance features is dependent an the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 2 of 6 Typical Wiring Modules will accept #18 AWG l0.75mm21. #16 11.0mm21, #14 AWG 11.50mm1 and #12 AWG 12.5mm21 wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG l0.75mm21 are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed Red LED (Alarm/Active) TB2 876 . . S - —4C) © 4321 TB1 Green LED (Normal) Notes f DATA IN (+) > 1 DATA IN(-) > From Signature Controller or Previous Device DATA OUT (+) DATA To Next Device .\ Refer to Signature Loop Controller Installation Sheet for wiring specifications. NFPA 72 requires that the SIGA-CR/SlGA-MCR be installed in the same room as the device it is control- ling. This requirement may not apply in all markets. Check with your local AHJ for details. The SIGA-UI06R and the SlGA-U102R do not come with TB14. The SIGA-U106 does not come with TB8 through TB13. Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). S SIGA-CR Control Relay Normally Open Common Normally Closed A 1234 Data In + + - \ No connections required for Data Out ) SiGA-MCR. Other modules - / may require connections. 14 Green LED (Normal) . . Red LED (Active) T515 1234 No connections required for SIGA-MCR. Other modules may require connections. SIGA-MCR Control Relay Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 3 of 6 I-. Q Audible Bases + < < (120)000 6254A-003 EOL Relay required for supevision Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. SIGA-AB4G SIGA-AB4G SIGA-AB4G Audible Base Audible Base Audible Base Listed 24 VDC Nominal Power Supply Signature Controller SIGA-CRR Schematic Power r Posrer Out PouyRenerses - - Wt,enrictrvotod 4321 Optional SlGA-CR for disabling/disconnecting sounder base SIGA-MCRR Schematic Power In Power Out Polarity reverses - + when activated. 0 SIGA-MCRR Notes Refer to the Signature controller installation sheet for wiring. A One Pair of Wires 24 Vdc power). One Pair of Wires (Signature Data). Single Wire (24 Vdc power). A The SIGA-uI06R and the SIGA-UIO2R do not come with TB 14. The SGA-U106 does not come with TEE, through TB13. A Supervised and power-limited. lithe source is nonpower-lirnited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG 12.5 mm') wire; Minimum #18 AWG 10.75 mm'). 10 End-of-Line Relay must monitor and report power sup- ply trouble to control pane). 11 Class B Data wiring may be "T-topped.' Signature Data Data Out + Circa: Vdc power IVI For normal operation For General Fire Alarm Operation ULJIJLC Listed 24 supply or ii 1234 .234 series motherboard Data Out nature Sig No II connections required for SIGA-MCRR. Other modules 'ta 2 TB14 may require connections. 1 TB7 1K CK .. Data In to Green LED (Normal) 3 Red LEO (Active) No connections required for Green LED (Normal) . SIGA-MCRR. Other modules Red LED (Active) may require connections. Optional SIGA-MCRR or SIGA-MCR for disabling/disconnecting No connections required for SIGA-MCRR. an audible base Other modules may require connections. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 4 of 6 S S SIGA-CTI Specifications -. .'Coalog Number -.-,- SIGA-CR SIA-MC SiGA-CRi :. SIGA-MCRR Control Relay T Polarity Reversal Relay Description Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby = 100pA Activated = 1001JA Operating voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C" 24 VDC = 2 amps (pilot duty) 120 Vac = 0.5 amps 220 Vac (non-UL) = 0.5 amps Mounting North American 21h inch (64 mm) deep 1-gang boxes and 11h inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA-MP mounting plates Plugs into U102R, UI06R or U106 Motherboards North American 21h inch 164 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA-MP mounting plates Plugs into U102R. UI06R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA - - - Ordering Information Catalog Number SIGA-CR . Descriptipn ControlRelay Module (Standard Mount) - UL/ULC Listed Ship Weight- lbs (kg) 0.4)0.15) SIGA-MCR Control Relay Module )UIO Mount) - UL Listed 0.18)0.08) SIGA-CRR • Polarity Reversal Relay Module (Standard Mount) - UL/ULC Listed - 0.4)0.15) SIGA-MCRR Polarity Reversal Relay Module (UIO Mount) - UL Listed 0.18)0.08) 27193-11 Related Equipment Surface Mount Box - Red, 1-gang 1)0.6) 27193-16 Surface Mount Box - White, 1-gang 1(0.6) SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) SIGA-U106R SIGA-UI06 Universal Input-Output Module Board w/Riser Inputs - Six Module Positions Universal Input-Output Module Board - Six Module Positions 0.62 (0.28) 0.56)0.25) S(GA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) MFC-A Accessones Multifunction Fire Cabinet - Red, supports Mounting Plates _Signature _Module 7.0)3.1) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) S Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page of 6 S GE Security Signature Series Overview 1888-378-2329 F 866-503-3996 The Signature Series intelligent analog-addressable system from GE Security is an entire Canada family of multi-sensor detectors and mounting bases, multiple-function input and out- T519 376 2430 put modules, network and non-network control panels, and user-friendly maintenance F 519 376 7258 and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature Asia 1852 2907 8108 device measures and analyzes the signal and decides whether or not to input an alarm. The F 852 2142 5063 microprocessor in each Signature device provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Corn- Australia munication. 161392594700 F 61 392594799 Self-diagnostics and History Log - Each Signature Series device constantly runs self- Europe checks to provide important maintenance information. The results of the self-check are T 32 2 725 1120 automatically updated and permanently stored in its non-volatile memory. This information F 32 272186 13 is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Latin America Program/Service Tool. The information stored in device memory includes: T 305 593 4301 e Device serial number, address, and type F305 593 4300 Date of manufacture, hours of operation, and last maintenance date' www.gesecurlty.com Number of recorded alarms and troubles' © 2006 General Electric company e Time and date of last alarm' All Rights Reserved Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Signature Series is a Trademark of GE Security. Automatic Device Mapping -The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing informa- tion showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configura- tion and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. On- board intelligence permits the device to operate in 1EST3 V.2 only. 'Retrievable with SIGA-PRO programming tool. a imagination at work Data Sheet 85001-0239 issue 7 Not to be used for installation purposes. Page 6 of 6 RELAY ENERGIZED LED 77 BLIJ c YEL N C 10.0 AMP CONTACTS %:fO:RG: N.O. 115 VAC @ 15 mA —24 VAC @15 mA 24 VDC @15 mA GE EST Fire & Life Safety Security Accessories Overview The PAM-1 Relay is encapsulated multi-voltage device providing 10 Amp Form C contacts. The relay may be energized by one of three input voltages: 24 Vac, 24 Vdc, or 115 Vac. A red LED is provided which, when illuminated, indicates the relay coil is energized. The PAM-1 may be mounted by using the double-sided adhesive tape, the self-drilling screw, or loosely placed in a back box. The PAM-1 is ideal for applications where remote relays are re- quired for control or status feedback. They are suitable for use with HVAC, Temperature Control, Fire Alarm, Security, Energy Manage- ment. and Lighting Control Systems. Standard Features Completely encapsulated 10 Amp relay Relay may be energized by one of three input voltages Contains a red LED which illuminates when relay coil is ener- gized May be mounted by double-sided adhesive tape, self-drilling screw or placed in back box Convenient 6 in (150mm) wire leads for electrical connections Wiring Multi-Voltage Control Relay Model PAM-1 Data Sheet 270066 Issue Li Not to be used for Installation purposes. Page 1 of 2 Security Specifications 1888-378-2329 F 866-503-3996 Power Requirments 15 mA per position © 24 Vdc, 24 Vac, 115 Vac Canada Relay IJL Recognized SPDT 15193762430 Contact Rating 10 Amps © 115 Vac F 519 376 7258 Ambient Temperature -58°F to 185°F (-50°C to 85°C) Asia Approvals UL Recognized components __________--_____________ 1852 2907 8108 1.5 H x W.875 D inches (38.1 x 24.5 x 22.2 mm) Dimensions F 852 2142 5063 with 6 inch (150mm) wire leads 18 AWG (1.00mm2) Australia T 613 9259 4700 F 613 9259 4799 Ordering Information Europe 13227251120 Model Descri tion p.. F 322 72186 13 PAM-1 Single SPDT relay with LED double-sided adhesive tape, mounting screw and Gin (150 mm) leads Latin America 13055934301 F 305 593 4300 www.gesecurlty.com iSP 2006 General Electric Company All Rights Reserved imagination at work Data Sheet 270066 Issue 1.1 Not to be used for installation purposes. Page 2 of 2 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:121 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CTI, SIGA-CT2, SIGA-CR, SlGA-CRR, SIGA-UM, SlGA-MMI, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SIGA-MCR, SlGA-MCRR remote transponders. Models SIGA-AA30, SIGA-AA50 audio amplifier. Models SIGA-APS, SIGA-APS-220 power supply. Models SIGA-MB4, *SIGA..Mp1 *SIGA..Mp2 *SIGAMP2L mounting plates; Models SIGA-UlO2R, SlGA-U106, SlGA-Ul06R motherboards. Model CS-SlGA-CC1 P releasing module. Models SIGA-CC1S and SIGA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev. 09-07-2005 ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager / CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM /LISTING SERVICE LISTING No. OO.c0 Page 1 of 1 CATEGORY: Z71 .Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: Richard Steele (248) 332-3900 FAX (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR-201/C, MR-201/CX, MR-204/C, MR-204/CX, PAM-1, PAM-2, PAM-2X, PAM-3, PAM-4, PAM-SD, RICA, RIC-2, *Rlc.3 *Rlc4 *MR..Rlc301 *MR..RIc..305 *MR..Rlc..401 and *MR..Rlc..405 relay modules. Models MR-101/C, -201/C and -201/CX may employ suffix -R or -S. *The MR-RIC series relay modules will employ /T, IC, or /C/R suffixes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. S APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. Rev. 03-01-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. S Date Issued: MARCH 21, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Bergelectric Corp. tb rs & Engineers . NOTIFICATION APPLIANCES S S 650 Opper Street 9 Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 • C10485046 ire & Life Safety 9 Security Notification Appliances Overview The Genesis line of signals are among the smallest, most compact audible-visible emergency signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, GE Security Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts em- ploying this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "T° pattern, significantly exceeding UL-1971 and ULC-S526 light distri- bution requirements. Genesis strobes and horn-strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unau- thorized tampering. Genesis signals feature textured housings in architecturally neutral white or traditional fire red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occupants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Unique low-profile design - The most compact UL-1971/ULC-S526 listed strobe available - Ultra-slim - protrudes less than one inch from the wall - Attractive appearance - No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 cd model available Easy to install - Fits standard 1-gang electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribution - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improves wall penetration - Industry's first temporal strobe output Field Configurable Horns and Strobes Genesis Series A pending 'x. \One or more " patents pending. CE • L-- Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 1 of 6 - Application Genesis strobes are UL 1971-listed for use indoors s ountei public-mode notification appliances for the hearing impoie Prevailing codes require strobes to be used where ambient noise Eond1ior.s.exceedJfl5.da4 (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Although all Genesis strobes are self-synchronizing, when installed with an optional synchronization module, strobe flashes from devices on the same circuit synchronize to within 10 milliseconds of each other indefinitely. This exceeds the two-hour minimum specified in the UL standards. Only one synchronization module is required per circuit. The following guidelines are based on ANSI/NFPA 72 National Fire Alarm Code 119991. When applied and installed in accordance with that code, GE Security strobes meet or exceed the illumination pro- duced by the ADA-specified 75 candela (cd) strobe at 50 feet.* Non-Sleeping Rooms and Corridors: GE Security strobes rated at less than 110 cd per UL 1971 are intended for use in non-sleeping areas only. Install with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches 12.4 ml above the finished floor. No point in any space (including corridors) required to have strobes should be more than 50 feet (15.2 ml from the signal (in the horizon- tal plane). Non Sleeping Rooms Use One Wall bunted t1odl Up to 20'x 2016.1 x 6.1ml One 15 cd strobe Up to 30'x 30'19.1 x 9.1ml One 30 cd or two 15 cd strobes Up to 40'x 40'(12.2 m 12.2 ml One 75 cd or two 30 cd strobes Up to 50'x 50115.2 x 15.2m) One 110 cd or two 75 cd strobes Corridors V/all Mounted Model Any Length x Max. 20 15 cd strobes spaced at 100' 130.5 ml 16.1ml Wide max. Strobes must be placed within 15 (4.5m) of each end of the corridor. * ADA suggests using 75 cd strobes throughout an area, with spacing that never exceeds 50 ft from the strobe to any point in the protected space. Sleeping rooms: GE Security 110 cd strobes are intended for use in sleeping rooms and should be installed along with a smoke detec- tor. It must be wall mounted at least 80" (2.03 ml above floor level, but no closer than 24" (610 mm) to the ceiling. The distance from the strobe to the pillow must not exceed 1614.8 ml. Sleeping Rooms Use One Wall Mounted Model Any Size 110 cd within 16 feet of pillow For 177 cd ceiling horn-strobes, please refer to data sheet 85001-0559 Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent wall pen- etration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 d above the maximum sound level having a duration of at east60 seconds, whichever is greater, measured 5 feet (1.5 ml above the ambient sound level is, A-weighted sound pressure measured over a Doubling the distance from the *will theoretically result in a 6 dB reduction of the received sound pressurt ef- fect depends on the acoustic properties of materials in the sp dBA difference represents a barely noticeable change in volume. Application Notes - USA Audible signals in the public mode should never have a sound level less than 75 dBA at 10'13 ml per NFPA 72. Signals cannot exceed 120 dBA per ADA and NFPA 72 at the minimum hearing distance to audible appliance. Strobe and combination horn/strobe devices should be installed with the bottom of the device at least 80 inches (2.0 ml and no more than 96 inches 12.4 ml above the finished floor. Horns should be installed with their tops not less than 6 inches (152 mm) below the ceiling and not less than 90 inches (2.3 ml above the finished floor. Strobes must be used to supplement audible signals wherever the average ambient sound level exceeds 105 dBA. Combination audible/visual signals must be installed in accordance with NFPA guidelines established for strobes. ADA requires visible signals in the following areas: rest rooms, meeting rooms, and other common use areas. sleeping rooms intended for use by persons with hearing impair- ment (in accordance with Title 1 of ADA). work areas used by a person with a hearing impairment (per Title 1 of ADA). Application Notes Canada (Based in part on 1995 Canada National Building Code) The fire alarm signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from an audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambi- ent levels, and never less than 65 dBA. In sleeping rooms the sound pressure level from on audible signal shall not be less than 75 dBA when any intervening doors between the device and the sleeping room are closed. Audible signal devices shall be installed not less than 1.8 m to the center of the device above the floor (per CAN/ULC S524l. The fire alarm audible signal shall be supplemented by fire alarm strobes in any floor area where the ambient noise level exceeds 87 dBA, or where the occupants of the floor area use ear protective devices, are located within on audiometric booth, or are located within sound insulating enclosures. This also applies to assembly occupancies in which music and other sounds associated with performances could exceed 100 dBA Strobes shall be installed in a building so that the flash from one de- vice is visible throughout the floor area or portion thereof in which they are installed. For maximum safety, GE Security recommends that strobes be installed as per the guidelines shown here under Strobe Spacing. Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 2 of 6 Genesis Horn/Strobe with optional trim plate Installation Genesis horns and strobes mount to any standard one-gang sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pie-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. ured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal cir- cuit. A Genesis Signal Master is required when horn-strobe models are configured for coded systems. Non-temporal, horn-only models sound a steady tone. Genesis strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be config- Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. Note: Strobes must have continuous voltage. WARNING: These devices will not operate without electrical power As fires frequently cause power interruptions, we suggest you discuss further safeguordswith your local fire protection specialist These visual signal appliances flash intensity may not be adequate to alert or waken occupants inthe protected area Research indicates that the intensity af strobe needed to awaken 90% of sleeping persons is approximately 100cd GE Security r ds that strobes in sleeping rooms be 110 ad minimum S® Polarity alarm a 0 next device end of line device Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 3 of 6 Horns Wall Temporal Horns (G1-HD UL High dB (RMS), Lea dB (RMS) 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16 Vfwr 51 37 24 Vfwr 69 - 52 33 Vfwr 76 70 Typical High dB Current RMS Mean Low dB RMS Mean 16 Vdc 22 1 17 17 14 20 Vdc 24 19 19 16 24 Vdc 27 21 22 18 33 Vdc 32 25 26 22 16 Vfwr 34 15 1 30 14 20 Vfwr 40 19 34 16 24 Vfwr 45 21 - -38 18 33 Vfwr 52 24 47 22 Wall Horns (G1-P) Max. Current, UL Designation Voltage Range' FillS Regulated 24 Vdc 16-33Vdc 13mA 24fwr ,j 16-33Vfwr 11mA 24 Vdc 10 10 24 Vdc 11 11 31 Vdc 12 12 20 Vfwr _J 8 24 Vfwr 10 9 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. GE Security recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean cur- rent) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. Z. Current Draw Strobes, Horn-Strobes Multi-cd Wall Strobes (G1-VM) UL 15 cd 30 cd* 15/75 cd 75 cd llocd* Rating RMS RMS RMS RMS RMS 16 Vdc 103 141 106 255 311 16 Vfwr 125 179 170 346 392 *G1_VM multi-cd: **G1F_V1575 fixed 15/75 cd Typical 15 cd 30 cd H Current RMS Mean RMS Mean - RMS Mean RMS Mean RMS Mean 16 Vdc 85 79 127 124 150 140 245 243 285 283 20 Vdc 71 66 98 96 123 114 188 186 240 238 24 Vdc 59 55 82 80 104 97 152 150 191 190 33 Vdc 46 44 64 63 84 77 112 111 137 136 16 Vfwr 119 64 169 97 223 126 332 203 376 240 20 Vfwr 103 51 143 76 189 100 253 150 331 198 24 Vfwr 94 44 129 65 169 85 218 121 262 152 33 Vfwr 1 87 37 112 1 52 1 148 1 68 1 179 89 205 106 Wall Temporal Horn-strobes - High dB Setting UL 15 5 1 _30 11'O 15/75 *G1_HDVM multi-cd Rating cd* I cd cd cd* cd" **G1F4DV1575 fixed 15/75 cd RMS RMS 167 1761230 RMS 281 397 I RMS tRMS 337 172 443 16 Vdc 129 16 Vfwr Typical 15 cd 30 cd 15/75 75 cd ' 110 cJ Current RMS Mean RMS Mean RMS Mean RMS Mean RMS I Mew 16 Vdc 102 89 135 129 160 152 246 242 309 1 305 20 Vdc 88 77 109 104 137 129 193 190 248 243 24 Vdc 81 71 94 90 122 114 161 158 203 200 33 Vdc 74 64 72 74 106 98 124 121 154 151 16 Vfwr 144 77 182 106 247 143 352 212 393 249 20 Vfwr 141 68 162 87 220 120 274 158 362 210 24 Vfwr 1 136 65 152 76 203 106 235 133 282 1 165 33 Vfwr 1 125 54 144 65 196 94 201 101 232 1 123 Wall Temporal Horn-strobes - Low dBSetting 15 1 30 75 110 15//5 UL Ratfng cd* cd* cd* cd* cd' RMS RMS RMS RMS RMS 16 Vdc 122j 160 .274_1._130 146 *G1HDVM multi-cd 16 Vfwr 1621216 383J 429 231 **G1FHDV1575 fixed 15/75 cd typical 15 cd 30cd .15/75 :75 Cd '110 cd Current RMS Mean RMS Mean RMS Mean ,RMS Mean RMS Mean 16 Vdc 96 84 130 124 158 1149 243 240 302 297 20Vdc 79 70 104 99 133 124 189 186 241 237 24 Vdc 68 61 88 84 119 110 156 154 197 193 33 Vdc 56 52 71 68 100 93 118 116 146 143 16 Vfwr 128 69 180 104 241 139 344 204 389 244 20 Vfwr 118 60 157 84 213 115 266 156 343 200 24 Vfwr 113 54 144 74 195 101 230 128 279 161 33 Vfwr 112 48 137 64 1-82—F 87 197 99 226 117 Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 4 of 6 S utput 1eriiral Horns, Horn-strobes (Gl-HD, G1-HDVM series) • UL464 Average . Peak High ds Setting - Temporal Steady, Temporal! Steady- -Temporal/ Steady 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 1 96.9 - 99.5 464 erag Lo wdB Temporal! Temporal! Setting Temporal Steady Steady Steady 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at loft) Light output - (effective cd) S Percent of UL rating versus angle Steady Tone Horns (G1-P series) UL464 [age Peak 16 Vdc 77 dBA, min 85 dBA 91 dBA 16 Vfwr 77 dBA, min 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet 13.01m). UL464 values measured in reverberation room. Average and Peak values are measured in onechoic chamber. . "'"" ' - Specifications Housing. Red or white textured UV stabilized, color impregnated engineered pl a s t i c . E x c e e d s 9 4 V - 0 U L f l a m m a b i l i t y r a t i n g . Lens Optical grade polycarbonate (clear) M • mounting Flush mount: 2½ inch (64 mm) deep one-gang box (indoor wall mount only) Surface mount: Model 27193 surface mount box, wiremold box, or equivale n t s u r f a c e - m o u n t b o x With optional trim plate: One-gang, two-gang, four-inch square, oct a g o n a l , o r E u r o p e a n s i n g l e - g a n g b o x Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG 1 0 . 7 5 m m 2 to 2.5 mm2) wire size Operating environment Indoor only. 32-120F 10-49°C) ambient temperature. 93% relative hum i d i t y Agency listings/approvals UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CSFM, CE, FCC, (MEA, F M p e n d i n g ) . (All models comply with ADA Code of Federal Regulation Chapter 2 8 P a r t 3 6 F i n a l R u l e . ) Dimensions )HxWxD) Signal: 4-1/2" x 2-3/4" x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5"(127 mm): Height - 5-7/8"(149 mm): Depth - 1h"(13 mm) G1-HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unf i l t e r e d 1 6 - 3 3 V d c F W R ( or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes: non-coded, filtered 16-3 3 V d c o r u n f i l t e r e d 1 6 - 3 3 V d c F W R ) o r c o d e d ( a u d i b l e NAC only) when used with optional G1M Genesis Signal Master) G1-VM series strobes: non-coded, filtered 16- 33 Vdc or unfiltered 16-33 Vd c F W R G1-P series steady-tone horns: coded or non-coded, filtered 20-31 V d c o r u n f i l t e r e d 2 0 - 2 7 v f w r UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 c d o u t p u t Strobe output rating UL 1971: 15 cd (fixed 15/75 cd mode)sl UL 1638, ULCS526: 75 cd )fixed 15/75 cd models) G1-VM strobes and G1-HDVM series temporal-tone horn-strobes: one flash p e r s e c o n d s y n c h r o n i z e d w i t h o p t i o n a l G 1 M Strobe flash rate Genesis Signal Master indefinitely within 10 milliseconds )or self-synchr o n i z e d w i t h i n 2 0 0 m i l l i s e c o n d s o v e r t h i r t y m i n u t e s on a common circuit without G1M Genesis Signal Master) Temporal s e t t i n g ( p r i v a t e m o d e o n l y ) : s y n c h r o n i z e d t o t e m p o r a l output of horns on same circuit Compatible synchronization G1M, G1M-RM, SlGA-CC1S, SIGA-MCC1S modules* G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-st r o b e s : t e m p o r a l r a t e s y n c h r o n i z e d w i t h o p t i o n a l Horn pulse rate G1M Genesis Signal Master indefinitely within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without G1M Genesis Signal Master) G1-P s t e a d y - t o n e h o r n s : c o n t i n u o u s , s t e a d y t o n e o n l y Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF. ½ sec ON, 11h sec OFF, then repeat cycle * Not compatible with G1-P Series horns. Data Sheet 85001-0573 Issue 6 Not to be used for Installation purposes. Page of 6 GE Security U.S. T 888-378-2329 F 866-503-3996 Canada 1519 376 2430 F 519 376 7258 Asia 1 852 2907 8108 F 852 2142 5063 Australia T 613 9259 4700 F 613 9259 4799 Europe 1 32 2 725 1120 F 32 2 72186 13 Latin America 13055934301 F 305 593 4300 svw.gesecurity.com © 2006 General Electric Company All Rights Reserved Ordering Information "Etciog Numb e r Ship Wt.. White Red Description Finish Finish GI-HDVM G1R- Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, HDVM selectable high/low dB output) G1-VM G1R-VM Genesis Strobe (selectable 15, 30. 75, or 110 cd output) G1-HD G1R-HD Genesis Temporal Horn (selectable high/low dB output) G1-P G1R-P Genesis Steady Horn (not compatible with Genesis Signal Master) G1F- G1RF- Genesis Horn-Strobe (selectable 15, 30, 75, or 110 cd output, HDVM HDVM selectable high/low dB output) -wfth "FIRE" marking G1F-VM G1RFVM Genesis Strobe (selectable 15, 30, 75, or 110 cd output) 0.25 -with "FIRE" marking (0.11) G1F-HD G1RF-HD Genesis Temporal Horn (selectable high/low dB output) -with "FIRE" marking G1F-P G1RF-P Genesis Steady Horn with "FIRE" marking (not compatible with Genesis Signal Master) G1F- G1RF- 15/75 cd temporal horn-strobe, hi/lo dB-24V HDV1575 H0V1575 - with "FIRE"marking (see note 1) G1F- G1RF- 15/75 cd strobe - with FIRE marking (see note 1) V1575 V1575 Genesis Series is a Trademark of GE Security. Mounting Accessories G1T GIRT Genesis Trim Plate (for two-gang or 4" square boxes) 0.15 (0.7) G1T-FIRE GIRT- Genesis Trim Plate (for two-gang or 4" square boxes) 015 10.71 FIRE with "FIRE" markings 27193-16 27193-11 One-gang surface mount box 1(0.4) SynchronioPon Modules . G1M JenesisgnolMaster - Snap-on Mount G1M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2(0.1) SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 10.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18(0.08) Note 1: These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd out put component complies with UL1971, while the 75 cd output component complies with UL 1638, I FIRE ! Genesis Horn-Strobes may be ordered in red or white, with or without 'FIRE' marking. Order matching trim plates separately. imagination at work Data Sheet 85001-0573 Issue 6 Not to be used for installation purposes. Page 6 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:218 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models GI-VM, GIR-VM, GIF-VM, GIRF-VM, GI41575, GIR41575, GIF-V1575, and GI RF-V1575 synchronizable type strobe lights. The suffix R refers to red rather than white housing and the suffix F refers to the word "FIRE" refers to a silk-screened word "FIRE" on the strobe housing. Refer to listee's data sheet for additional detailed p r o d u c t description and operational considerations. RATING: Electrical: 16-33 V dcNFWR Candela: G1-VM series 15cd, 30cd, 60cd, 75cd, 110cd Selectable GI-V1575 series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & o r d i n a n c e s and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control u n i t s . Units are synchronizable when used with Models G1 or G1M-RM sync module (C S F M Listing No. 7300-1657:201) which may employ Models SIGA-CC1 S or SIGA-MCC1 S Auto-Sync output modules as an accessory (CSFM Listing No. 7300-1657:121). For indoor use and wall mount only. NOTE: Formerly 7125-1591:218 08-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listi n g i s n o t a n e n d o r s e m e n t o r ... ., recommendation of the item listed. This listing should not be used to verify correct operational re q u i r e m e n t s o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sour c e s . Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING , BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-1657:202 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: GE Security, Inc., 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 DESIGN: Models "EST' GI-HV15, -HV30, -HV60, -HV-75, GI-HOVI5, -HOV30, -HOV60, -H0V75, -HOVI10, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOVIIO, GIRF-HOVIS, -HOV30, -HOV60, -H0V75, -HOVIIO, GI-HDVM, G1R-HDVM, GIF-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, GI- HDV1575, GIR-HDV1575, GIF-HDV1575, and GIRF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 VdcNfwr - Models GI-HDVM, GIR-HDVM, G1F-HDVM, G1RF- HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCF-HDVMH, G1-HDV1575, GIR-HDV1575, G1F-HDV1575, GIRF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, ll0cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, Gi R-HDV1575, Gi F-HDV1575, S GIRF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135- 1657:230). For indoor use and wall mount only. Models GC-HDVM and GCF-HDVM for ceiling mount only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Formerly 7125-1591:202 08-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listing is not an endor s e m e n t o r recommendation of the item listed. This listing should not be used to verify correct operational requirem e n t s o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Bergelectric Corp. Contractors & Engineers S II BATTERIES S S 650 Opper Street • Escondido, CA 92029 • Tel (760) 746-1003 9 Fax (760) 746-4619 • C1O-#85046 UB12350 (12V35Ah) NOTE S Nominal Voltage 12V Nominal Capacity (20HR) 35Ah Length 197 +/-lmm(7.76 inches) D. Dimensions Width 130 +/-lmm(5.12 inches) Height 156 +/-lmm(6.14 inches) Total Height 180 +/-lmm(7.09 inches) Weight Approx. 11.107 kg (24.441bs) Standard Terminal B1-M5 bolt & nut Dimensions (inm):+/.mm 130 ni 156 180 196 Standard Tenninal tam B! 16 8.75 ri 16 1 (IS bolt & nut) 0 UB12350 (12V35Ah) Max. Discharge Current (5 sec.) 180A 20 hour rate (1.7A) 35 Ah 10 hour rate (3.0A) 30.5 Ah Capacity Cycle 14.4 to 15.0V (-30mV/°C) 5 hour rate (5.4A) 21.6 Ah Constant 1 hour (20A) 18 Ah Voltage Charge Internal Resistance Fully charged battery (20°C, Standby 13.5 to 13.8V (-20mV/°C) 68°F) 10milliohms - - 2571 - - - 13,0 = 12.0 171 R 9.0 I ------ 8.0 .1 2A 62A 4A 1 2 3 5 10 20 30 60 2 3 5 10 20 30 h. DdiargeTiine - - - - Dischar2ecaracteristics 0C,32 L - 13.0 12.0 '1lo 17A - \ \ LL 102A 62i 4A 1 2 3 5 10 20 30 60 2 3 5 10 20 30 nn Discharge Time