5781 VAN ALLEN WAY; ; AS120133; Permit
1/31/25, 4:15 PM AS120133 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5781 VAN ALLEN WY Permit Type: SPRINK Parcel No: 2121304400 Lot #: 0 Reference No.: PC #: Permit No: A5120133 Status: APPROVED Applied 10/11/2012 Approved: 10/18/2012 Issued: 10/18/2012 Inspector: Project Title: LIFE TECHNOLOGIES MFP T.I. Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: THE G C NET LEASE (CARLSBAD) INVESTORS L L C C/O LIFE TECHNOLOGIES CORP 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) L Balance ($) 268 0 268 0 about:blank 1/1 San Diego Branch Office .00696 I CO 10695 Treena Street, Suite #105 .. I.... San Diego, CA 92131 .... I.' Fire (858) 444-2000 fax: 444-2056 Protection State License No: C-16-5 77621 www.coscofire.com MATERIAL SUBMITTAL Date: 10/5/12 Life Technologies MFP 5781 Van Allen Way Carlsbad, CA 92008 JOB # 10.CD-5418 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: Linda Collier Los Angeles 0 San Francisco • Orange 0 Fresno • San Diego • Seattle 0~' &I RA i &X1 7kA Aw#Af 'VAn Schedule-1O/Schedule-40 - ABFII Fully Listed and FM Approved Sprinkler Pipe When you specify Allied Schedule-10/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (lh/4"_ 8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. > Galvanized Pipe Schedule-10/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII". In scientific labOratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* > American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Schedule-1 0/Schedule-40 - ABFII pipe are in compliance with the following: ASTM A-135, Type [Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture * See ABFII warranty 1 1[.]lI. NPS In; mm Nominal I.D. In; mm Wt. Wt. (H20 Filled) CRR - Lbs/Ft; kg/rn Lbs/Ft; kg/rn 25 1.049 26.6 1.680 2.5 2.05 3.05 1 - 1¼" 32 1.380 35.1 2.270 2.93 - - 4.36 4.36 1112" 40 1.610 40.9 2.720 4.0 3.61 5.37 1 - 50 2.067 3.650 5.4 -513 1 52.5 21/2" 2.469 62.7 5.790 7.86 11.73 1 - 65 8.6 1 li.iii. NPS In; mm Nominal I.D. In; mm Wt. Lbs/Ft; kg/rn Wt. (H20 Filled) CRR - Lbs/Ft; kg/rn 11/a" - 32 1.442 - 1.810 2.7 2.525 3.75 7.0955 36.6 - 11/2 40 1.682 2.080 3.1 3.04 4.52 5.6570 - 42.7 2.157 2.640 3.9 4.22 6.28 4.5827 - 50 54.8 21/2" 2.635 3.530 - 5.3 5.89 8.77 3.5196 - 65 66.9 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 - 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 - 59.75 - flVID Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 9~alhed • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 ***O 02011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1 105 C.I. THREADED FITTINGS V .5 FITTINGS A Di'jth,n ,fSW.rPip Products CASTIIRON 90 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIM IONS WEIGI-IT I A B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 1 2.25 2.90 21/2 CB90077 300 2.70 1 2.70 4.75 ff L CAST IRED. COU I t•] [C NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 I (' CAST :.u;i: I.eI'J,J4CUI;I.)Y! NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A - B 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1 1.13 1 1/4X1 CB90043 300 1.58 1.67 1 1.16 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1 1/2X1 CB90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 38 (q (~~ <t~> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CASTIIRON STRAIGHT TEE NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENS IONS WEIGHT I EACH PIECE - A - B 1 CT333 300 1.50 1.50 1.21 11/4 C1444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1.94 1 2.51 2 CT666 300 2.25 2.25 3.96 21/2 C1777 300 2.70 2.70 6.45 ICASTIIRONElDEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 1 CB450551 300 1 1.43 1.43 1.80 2 1 CB450661 300 1 1.68 1 1.68 2.79 E A CASTIl :t.] IPLUGS NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 1 300 1 1.25 1 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPLOO5 300 1.45 0.62 2 CPL006 300 1.56 0.91 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME B16.14. THREADS ARE NPT PERANSI/ASME 131.20.1. C.I. THREADED FITTINGS FITTINGS A Divfrio, ,fS far Pipe Prod LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIM B4SIONS WBGHT EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST1IRON1REDUCING T NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. ' DIMRISIONS I W8GHT' EACH PIECE A B C 1X1X1/2 CT33T 300 1.26 1.26 1.36 0.95 1X1X314 300 1.37 1.37 1.45 1.10 1X1/2X1 -F31 300 1.50 1.36 1.50 1.08 1X3/4X1 300 - 1.50 1.45 1.50 1.18 1X1X1 1/4 T4 300 - .r 1.67 1.58 1.52 1X1X1 1/2 300 - ff 1.80 1.65 1.73 1 114X1X112 CT4T 300 - ..4 1.26 1.53 1.17 1 114X1 X314 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1172F-CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 114X1 114X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 114X3/4 CT442 300 1.45 1.45 1.62 1.54 1 114X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 114X2 CT446 300 2.10 2.10 1.90 2.55 1 1/2X1X1/2 1,T531 300 1.41 1.34 1.66 1.41 1 1/2X1 X314 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1 X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1 X1 114 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1 X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 112X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 T 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22- 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 1 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 C1646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 C1664 300 1 I.F0_1 1.90 2.10 3.32 2X2X1 1/2 C1665 300 1 2.02 1 2.02 2.16 2x2x2 1/2 CT667 300 2.60 2.60 2.39 35.72 .10 Page 39 March 14, 2008 Sprinkler 41 a MICROFAST® AND '4J I FI FuuIGu l.1:IIEu'Jw. MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating 11250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http:/Iwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C 19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B, Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 MICROFAST® AND MicrofastHP® QUICK l:II[.1u'Lw RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 2002/930 = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A 1/2' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fats Protective Sprinkler Cap 1D:=106 96 Figure 1: Standard Sprinkler Wrench 10896013 March 14, 2008 Sprinkler 41c MICROFAST® AND NiKi MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 00) ' Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 00) 150 °F (65 00) Green High 286 °F (141 00) 225 °F (107 00) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. lii IH -Sprinkler 'french 12144'd/B** For installing coated and/or recessed pendent sprinklers Carefully slide the with protective cops ---------- wrench sideways around the protective cap, ensuring engage- ' rient with the sprinkler **A 1/200 ratchet is required wrench flats, (not available from Viking). Sprinkler 41d March 14, 2008 MICROFAST® AND "J I FI l:II[.u'7M MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com I I Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No." NPT BSP U.S. metric2 Inches mm cULus4 T FM5 NYC- VdS LPCB CE Standard Orifice 06662B VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 ] AIX, BIY I A3X, B3Y AiX, B1Y A3 A3X, 133Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4" 20 mm 80 115.2 2-3/8" 60 A1X, BIY A2X, B2Y AiX, B1Y -- A3X C313 -- 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- -- G3 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AiX, B1Y - AiX, B1Y A3 -- - -- Small Orifice' 067181311 VK329 1/2" 15 mm 28 40.3 2-3/16" 56 AiX, BIY A2X AiX, B1Y -- -- -- -- 06720B1° VK331 1/2" 15 mm 42 60.5 2-1/4" 58 AiX, B1Y -- AiX, B1Y -_ -- -- -- 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- -- A3 -- G2'4 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN - K-Factor Length (Refer also to Design Criteria onpage 41e.) Part No' NPT BSP US. metric2 Inches cULus4 FM NYC" VCIS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, B1Y - AiX - -- - -- Maximum 250 PSI (17 bar) WWP Small Orifice9 1229010 VK342 1 1/2" 1 15 mm 2.8 1 40.3 2-3/16" 56 1 AIX, B1Y - AiX -- -- -- -- Approved Temperature Ratings Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 "C) Approved Finishes x - Standard surface-mounted escutcheon or and 286 oF (141 oC) B - 135 °F (5; C) 155 °I (68 °C), 175°F (79 °C), and 200 °F (93 °C) 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F ester78, Black Polyester7'8, and Black Escutcheon12 (141 °C) Teflon®7 Y - Standard surface-mounted escutcheon or D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2 - Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 °C) 3- Brass, Chrome-Enloy®, White Polyester8, Escutcheon12 or recessed with the Viking 0g and and Black Polyester' Micromatic® Model E-i or E-2 Recessed Escutcheon °F °C) G - 155 (68 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is Men pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. 8 Qther colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12 The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the V( to be recessed behind the face of the wall or ceiling. 13(( Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. * March 14, 2008 Sprinkler 41e MICROFAST® AND N41KJM4 l:II[.u.7M MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com cULus Listing Reguirements: Microfast' and MicrofastHP11 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Anoroval Reguirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size 2-5/16" (58.7 mm) flifliflUfl 2-1/8" 2-1/2" (63.5 mm) mamum (54 mm) 1/2' (15 rim) _ NPT T 19221& 2-1/4" 1-5/8' (58 mm) (41 rip,) Pendent Sprinkler 06662B (VK302) 1-3/4" (44,5 mm) Installed with a standard 1/8" surface- mounted escutcheon. 1-1/2" (38.1 mm) Minimum Maximum Installed with a Microfast Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Sprinkler 41f March 14, 2008 MICROFAST® AND MicrofastHP® QUICK 4.J I F(J I1J RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com 2-1/8" CeiUng Opening Size 2-1/8" (54 mm) 2-5/16" (58,7 mm) minimum (54 mm) 2-1/2" (63,5 mm) maximum 1-3/4" (44.5 mm) 1~2 Maximum 1-1/8" (28,6 mm) Minimum (50,8 mm) 1~2 Maximum 1-1/8" (28,6 mm) Minimum Instaec with a Micromatic Mode( E-1 Recessed Escutcheon Instafleci with a thread on Mode' E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F 081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE - Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) August 13, 2009 Sprinkler 54a MIRAGES STANDARD AND '4. QR S CONCEALED PENDENT J I FJ I1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD-40249 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinkler VK463 is rated for use with water The Viking Corporation's Web site at working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) http://www.vikinggroupinc.com. sprinklers can be identified by locating "250" stamped on the deflec- The Web site may include a more recent tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65 °F (-55 C) Patents Pending *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G 10080, Finish: Clear Chromate over Zinc Plating Form No. F103005 Replaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). Sprinkler 54b August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT "sJ I FI F1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass LJNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix ("F/°C): 155"/68° = B, 175°/79° = D, 200"/93° = E For example, sprinkler VK463 with a 155 "F/68 "C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/5W1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 135"/57° UL (139°/59° FM) =A, 165°/74" = C For example, cover 13504 with a Polished Chrome finish and a 165 "F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a %" ratchet (not available from Viking). """Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. August 13, 2009 Sprinkler 54c MIRAGE® STANDARD AND QR CONCEALED PENDENT "4iI I I'I I416 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com I Sprinkler NPT Nominal Maximum Listings and Approvals4 Base SIN Thread Size K-Factor Water Working (Refer also to Design Criteria on page 54d.) Part No.' Inch mm U.S. Imetric2 Pressure cULus5 I FM I NYC6 I VdS I LPCB I CE StandardResponse Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) -- AU1,BX1 -- AY1,CZ1 - -- 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) -- - -- - AV2, BW2 AV2, BW27 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 -- AV1, BW1 - - AY2, C 2 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 -- AV1, BW1 - - - 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 -- AV1, BW1 -- -- -- Cover Plate Assembly Temperature Ratings9 U - 135°F (57 °C) cULus Listed cover 135041, 13642' (large diameter), Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings or 153941 (square cover plate) FM Approved as 139 °F(59 °C) 1 - Polished Chrome, Brushed Chrome, A 155 °F '68 / V- 135 °F (57 °C) cULus Listed cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, °F °C) W - 165 (74 cover 135041 or 136421 (large diameter) Brushed Brass, Brushed Copper, oF B - 175 (79 C) and 200 oF (93 C) x - 165 °F (74 °C) cover 135041, 136421 (large diameter), or 153941 Painted White, Painted Ivory, or C - 200 F (93 C) (square cover plate) Painted Black Y - 135 °F (57 °C) cover 135041 2- Polished Chrome, Painted White Z - 165 °F (74 °C) cover 135041 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for an additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. '((Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 °F cover has an orange label. The 165 °F cover has a white label. 10Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. AVAILABLETABLE 1: J rnoro Ordinary 100°F(38°C) 135°F(57°C)cULus Red I 139°F(59°C)FM Intermediate 175°F(79°C) I 150°F(65°C) I 165°F(74°C) I Yellow Intermediate 200°F(93°C) I 150°F(65°C) 165°F(74°C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler 54d August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT IF(IIs1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com cULus Listing Requirements: Mirage® Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Aooroval Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group Il. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. GUSi IL 1101% Identifi cation of Custom Faint Color All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint clot) of the paint on the label. Figure 1: Identification of Custom Paint Color for Concealed Covers DU NOT PAINT 3-5/16" (84.1 Figure 2: Square Cover Assembly 15394 Sprinkler Frame Arms Sprinkler Wrench Flat NEVER ins-tall the sprinkler by applying the installation wrench across the frame arms. August 13, 2009 Sprinkler 54e MIRAGE® STANDARD AND QR CONCEALED PENDENT "41I Il(AIF1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com 2-1/4" (57,2 rim) diameter opening is required in the ceiling. 11 ap Dr se Sprinkler Wrench (Part No O47W/B** is shown) '(A 1/2" ratchet ; required (not ilable from Viking), Step 2: Carefully press the Step I: Carefully slide the wrench upward and turn slightly wrench sideways around to ensure engagement with the the deflector and pins, sprinkler wrench flats. DO NOT over-tighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. DO NOT apply more than 25 ft. lbs. of torquie. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Correct Use of Wrenches 1/2" (15 rim) NPT 2-3/16" (55 mm) 2-1/16" (52 mm) Minimum -3/4" (70 mm) or 3-5/16" (84,1 mm) Note: Upon sprinkler activation the deflector descends to approximately 13/16" (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation January 27, 2012 Sprinkler 136g CLEANROOM SPRINKLER \1II(II%1G® COVER ASSEMBLY 136424CR The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 1. DESCRIPTION Viking Cleanroom Cover Assembly 136424CR is a low-profile cover intended for use in cleanroom environments with Viking Mirages Concealed Pendent Sprinkler VK462, MRI Sprinkler VK462 (listed as quick response), or Sprinkler VK464 (listed as standard re- sponse for this application). Note: Adding the seal does NOT change sprinklers VK462 OR listing. The silicone cover gasket is pre.-assembled with the concealed cover for an accept- able sprinkler seal for use in a cleanroom or clean zone. The cover assembly is installed flush with the ceiling to provide a smooth appearance, and is available in several stan- dard decorative finishes to meet design requirements. Viking concealed cover plate assemblies may also be custom ordered with any color by any paint manufacturer. The low-profile cover assembly is designed with a threaded adapter and provides up to 1/2 (12.7 mm) of vertical adjustment. The two-piece sprinkler and cover plate design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing tem- porary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 13 LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to the Approval Chart and Design Criteria on page 136i for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2009. Refer to the appropriate sprinkler technical page for sprinkler specifications. Material Standards: Cover Plate: Copper UNS-C1I000 Base: Brass UNS-C26000 or UNS-C26800 Gasket: Silicone Springs: Nickel Alloy Solder: Eutectic Viking Technical Data may be found on The Viking Corporation's Web site at http:/Iwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Ordering Information: (Also refer to the current Viking price list.) Cleanroom Sprinkler Cover Assembly: Base Part No. 136424CR (3-5/16" diameter) for Sprinkler VK462, VK464, and MRI Sprinkler VK462. Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-AN, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135°F (57 °C) =A, 165°F (74 °C) = C For example, cover 136424CR with a Painted White finish and a 165 °F (74 °C) temperature rating = 13642MC1W/CR. Available Cover Plate Finishes And Temperature Ratings: Refer to Table 1. INSTALLATION A. After installation of Mirage Concealed Pendent Sprinkler VK462 or VK464, testing of the system, repairing of all leaks, and installation and painting of the ceiling, the concealed sprinkler cover plate assembly may be attached. Remove the plastic protective cap from the sprinkler. Remove the cover plate assembly from the protective box, taking care not to damage the assembly. Gently place the base of the cover plate assembly over the sprinkler protruding through the 2-1/4" (57.2 mm) ceiling opening. Carefully push the cover plate assembly onto the sprinkler until the cover plate flange fits tightly against the ceiling surface. The maximum adjustment available is %" (12.7 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler nipple. B. DISASSEMBLY: Cover plates can be removed by gently unthreading them from the sprinkler body. C. RE-ASSEMBLY: The push-on feature of these cover plate assemblies allows easy installation of the cover plates. Gently place the base of the cover plate assembly over the sprinkler. Push the cover plate assembly onto the sprinkler until the cover plate flange fits tightly against the surface of the ceiling. Form No. F_022409 Replaces page 136g-j, dated June 24, 2011. (Added Sprinkler VK464.) (Protective Cap is removed for Installation--use Wrench 14031w0 2-1/4' (57.2 mm) diameter opening is required in the ceiling. Sprinkler Wrench (Part No, 4047/B)K* is shown) 1/2' ratchet required (not ble from Viking). a Sprinkler 136h January 27, 2012 CLEANROOM SPRINKLER COVER ASSEMBLY 136424CR The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to ihatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Concealed Sprinklers VK462 and VK464 and Cleanroom Cover Assemblies are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. CUST Q 0 Identification of Custom Point Color All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint dot) of the point on the label. Figure 1: Identification of Custom Paint Color - Concealed Covers COVER pPLATE ASSEMBLY TEMPERATURE RATINGS liIFINISHES II Ordinary F (38 °C) J 135 °F (57 C) Red Intermediate F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 150°F(65°C) I 165°F(74°C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Step 1: Carefully slide the Step 2 Carefully press the wrench wrench sideways around upward and turn slightly to the deflector and pins, ensure engagement with the sprinkler wrench flats. Sprinkler t Adapter Assembly NEVER Install the sprinkler Lj by applying the Installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047V/B or 14031. DO NOT apply more than 25 ft. tbs. of torque. A leak-tight seal should be achieved by turning the sprinkler clock- I wise 1 to 1-1/2 turns beyond finger tight. Figure 2: Sprinkler Installation and Correct Use of Wrenches Sprinkler Frame Arms Sprinkler Wrench Flat January 27, 2012 Sprinkler 1361 CLEANROOM SPRINKLER "J IF(II'1GJ l:ll[1U.7M COVER ASSEMBLY 136424CR The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Nominal I Maximum Water I Listings and Approvals3 (Refer also to Design Criteria below and Sprinkler Base I NPT Thread Size K-Factor Working Pressure I SIN SIN on the applicable sprinkler data page.) Pa Number' mm U.S. metric2 psi bar cULus4 FM NYC Quick Response Applications 13503A I VK462 1/2" I 15 I 5.6 I 80.6 175 I 12 I AWl, BX1 15480A VK462 (MRI) 1/2" 15 5.6 80.6 175 12 AWl, BX1 -- - Standard Response Applications 13614A VK464 3/4" 20 8.0 115.2 175 12 AWl, BX1 -- - Sprinkler Temperature Ratings Cover Plate Assembly Temperature Ratings5 Finishes of the Cover Plate Assemble A- 155 °F (68 °C) 1W - 135°F (57 °C) cleanroom cover assembly 13642-NCR' 1 - Polished Chrome, Painted White, B -175 °F (79°C) and 200 °F(93 °C) X -165 °F(74 *C) cleanroom cover assembly 13642-C/CR1 Painted Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. The 135 °F (57 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 6 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. cULus Listing Requirements: Viking Cleariroom Sprinkler Cover Assembly 136424CR is cULus Listed for use with the Mirage® Concealed Pendent Sprinklers VK462 (OR), VK464 (SR), and MRI Sprinkler VK462 (QR) in a cleanroom or clean zone for installation in accordance with the latest edition of NFPA 13 for cleanrooms when the following conditions are met: Wet systems shall be provided throughout the facility containing cleanrooms and clean zones. Sprinklers shall be installed in the plenum and interstitial space above cleanrooms and shall be hydraulically designed for a density of 0.2 gpm (8.15 L/min m2) over a design area of 3000 ft2 (278.8 m2). Sprinklers installed in duct systems shall be hydraulically designed for a density of 0.5 gpm (1.9 L/min) over an area derived by multiplying the distance between the sprinklers in a horizontal duct by the width of the duct. Minimum discharge shall be 20 gpm (76 Llmin) per sprinkler from the five (5) hydraulically most remote sprinklers. Sprinklers installed in ductwork shall be spaced a maximum of 20 ft (6.1 m) apart horizontally and 12 ft (3.7 m) apart vertically. A separate indicating control valve shall be provided for sprinklers installed in ductwork. The sprinklers shall be acessible for periodic inspection and maintenance. NOTE: Sprinkler VK464 is cULus Listed as a standard response sprinkler when using Cleanroom Sprinkler Cover Assembly 13642-A/CR. However, it is listed as a quick response sprinkler as indicated on sprinkler technical data page 55a-e when using Cover Assembly 13642 (for non-cleanroom applications). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the sprinkler data page (54a-e for Sprinkler VK462, 54p-t for MRI Sprinkler VK462, or 55a-e for VK464), and page QRI -3 or SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. (54 mm) Minimum Sprinkler 136j January 27, 2012 CLEANROOM SPRINKLER N41KJNG4 l:IIIUIjf COVER ASSEMBLY 13642-ICR The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 1/2" (15 mm) NFl 2-3/16" (56 mm) Gasket _\\\ 115I1i11 Cover AssemblyY 3-5/16" (84,1 mm) Note Upon sprinkler activation, the deflector descends to approximately 13/16" (20.6 mm) below the sprinkler body. Figure 3: Sprinkler VK462 Dimensions and Cover Installation 3/4" (20 mm) NFl 2-1/4" (57,2 mm) Gasket Cover Assembly 2-3/16" (56 mm) Minimum 3-5/16" (84.1 mm) Note Upon sprinkler activation, the deflector descends to approximately 13/16" (20,6 mm) below the sprinkler body. Figure 4: Sprinkler VK464 Dimensions and Cover Installation Form No. F_022409 Replaces page 136g-j, dated June 24, 2011. (Added Sprinkler VK464.) C@ US USTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed niy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786 5266 www.tolco.com Fig. 78 - All Steel Ceiling Plate Size Range - 3/8 rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 CIJS USTED UL Listed Fastener Table Pipe Size Qty Fastener Type Material 1/2-2 21/2 -4 1/2 -2 2 2 2 #14 x 1'/4 A-point hex-washer-head sheet metal screw 1/4 x 11/2 wood screws* 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2-2 1/2 -2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood thru 5/8 gyp board * No pre-drilling Dimensions • Weights Pipe Size A B C D E Max. Rec. Approx. Load Lbs.* Wt./100 1/2-2 5 - 6 3 21/8 11/8 5/16 3/8 Consult factory for data 150 15 * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH. 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com Component of State of California OSHPD Approved Seismic Restraints System FIG. 98 Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Plannina and Development (OSHPD). For additional load, spacing and placement information relatina to OSHPD oroiects. olease refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8 thru 7/8' rod in 1 'increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100- All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 3/8 1/2 240 730 1350 12 29 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737 0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2 thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2' thru 8') Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 2/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 2/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 1112 3/8 8mm or 10mm 3/8 27A 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 5/8 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 7/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 -- - 8 1/2 12mm 131/o 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com Wood Not less than Wood Flooring 2" nominal width Double She Ceiling Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. 1/4" 8002957 GST 100 1/4 xl" 25 125 #14 Black Nut Driver Part#8113910 1/4" 8003957 GST 200 1/402" 1760 (Fir) 25 125 1/4" 8004957 GST 300 114x3" 2060 (F) 25 125 1 3/8 8006957 GST.75 1/4x3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 1/40 10 210 (7/16" OSB) 300 25 12] 3/8" 8008957 GST 20 1/4x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/40 2" 1760 F)/) 850 25 125 1 3/8" 8009925 GST25-380 3/8x2-l/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 J 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 3/8" 8011925 GST4O 1/4x4" 2180 (Fir) 25 125 1 3/8' 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 - 1/2" 80/3925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1 #14SWRed 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (f)) 25 125 1 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 F 1/2 8017925 GST6 1/4x6" 2230 (Fir) 25 125 ] Nut Driver Part # 8114910 34 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com Product Features Eliminates distortion of threaded rod. "Saves time from traditional methods. Accommodates up to 3 %" x 12 pitch roof. • Reduces installation cost. Allows 17° deflection from vertical. • Made in the U.S.A. Rod Part Screw Ultimate UL Test FM Test Min Box Case Approvals Size Number Model Descriptions Pullout (Ibs Load (Ibs) Load (Ibs) Thickness Qty Qty 8139957 SH.GST2O 1/4x2" /257 (Fi) 1050 1475 25 125 125] 3/8° 8141957 SH.GST30 1/4o3" 1720 (Fir) 1500 1475 25 125 Not less than 2" nominal width (1-1/2") up to 3-1/2 pipe; not less than 3" (2-1/2) nominal width 4" & 5" pipe I Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bottom for main toes. Exception: This requirement shall not apply to 2" or thicker nailing ships resting on top of steel beams. Product Features No pre-drilling required. IN Floor Joist Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. i- #14 SW Red Nut Driver Part # 8114910 1/4 8018957 SWG 100 114x1" 622 (Eiri 25 125 1/4 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8 8020957 SWG 10 114 x V 622 ()ç) 300 25 125 3/8 8021957 SWG 20 1/4 x 2' 1725 (Fir) 1050 25 125 E• 3/8' 8073925 SWG 20-SS 1/402" 1725 (Fir) 850 25 125 1 3/8' 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Insert the appropriate nut driver into a 3/8"or 1t2' portable drill. Insert the SAMMYS into the #14 (black) nil driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver fight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4". 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2' requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. ii)f1 II11ik Insert the appropriate nut driver into a 3/8" or 112"porfable drill. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each bme. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. San Diego Branch Office .00006 cosco 10695 TreenaStreeL, Suite #105 1IIISs. San Diego, CA 92131 see • S • •• •.• (858) 444-2000 fax: 444-2056 Fire Protection State License No: C-16-5 77621 www.coscofire.com MATERIAL SUBMITTAL Date: 10/5/12 Life Technologies MFP 5781 Van Allen Way Carlsbad, CA 92008 JOB # lO.CD-5418 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: Linda Collier Los Angeles 0 San Francisco 0 Orange • Fresno • San Diego 0 Seattle V Sch _edu.1e=10/Schedu11e=40 ABF11 When you specify Allied Schedule-10/Schedule-40 - ABFII sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 - ABFII gives you the extra quality assurance you demand. Our Sch-10 (11/4"- 8") pipe and Sch-40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. > Galvanized Pipe Schedule-10/Schedule-40 -ABFII product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-i 23. > Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFll". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* > American Made Able to meet "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ) Specifications & Approvals Schedule-10/Schedule-40 -ABFII pipe are in compliance with the following: ASTM A-135, Type [Grade A, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture * See ABED warranty k.iii - NPS Nominal I.D. - Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/m' - 25 1.049 - 266 1.680 25 - 2.05 305 1 • 11/4 2.270 2.93 4.36 1 4.36-i 1½" 40 1.610 2.720 4.0 3.61 537 1 - 40.9 2" 50 2.067 52.5 3.650 . 5.4 5.13 7.63 1 - 21/2 2.469 5.790 7.86 8.6. 1 65 . 62.7 f r.ii - NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR .In; mm ln;dm ' LbslFt;kglm Lbs/Ft;kg/rn - 11/4 1.810 2.525 7.0955 32. 36.6 2.7 375 11/2 2.080 3.04 4:52 5.6570 - 40 . 42.7 3.1 2.157 2.640 4.22 4.5827 50 1 54.8 3.9 - 6.28 2½" 2.635 3.530 5.89 - - 3.5196 --g -- 3.260 4.330 7.94 2.5550 75 82.8 6.4 11.82 4.260 5.610 11.78 1.6020 100 7108.2 8.3 1753 5.295 7.77 17.33 1.4874 125 '-134.5 11.56 . 25.80 - - 6.357 9.290 23.03 1.0251 150 .1613 . 13.8 34.27 8" 8.249 16.490 40.15 - 1.8365 200 2095 245 5975 - ® Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube.sprinkler.com !' " 0 110 • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 °"" I'(9! 02011 Atkore International, Inc. All Rights Reserved. STP-S5-3-1 105 C.I. THREADED FITTINGS. FITTINGS (j Q LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTMA126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME B16.14. THREADS ARE NPT PER ANSI/ASME 131.20.1. tCAST IIRON 90 DEGREEELBOW1 NOMINAL SIZE (INCH) ITEM CODE I MAX. 1. WORKING P.S.I. DIMENSIONS WEIGHT - A - B EACH PIECE 1 CR90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CR90055 300 1.94 1.94 1.80 2 CR90066 300 2.25 2.25 2.90 21/2 CR90077 300 2.70 2.70 4.75 CASTIIRONIRED. COUP I [C NOMINAL SIZE (INCH) ITEM CODE I # MAX. WORKING P.S.I. DIM B4SION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST lIIRON I:1: DIMENSIONS WEIGHT EACH PIECE NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. - A 1 - B 1X1/2 CR90031 300 1.26 1.36 1 0.64 1X314 I CR90032 300 1.37 1.45 1 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 145 1.62 1.13 1 1/4X1 CR90043 300 1.58 1.67 1.16 1 1/2x1 1/2 CR90051 300 1.41 1.66 1.17 1 1/2x3/4 CR90052 300 1.52 .1.75 1.28 1 1/2X1 CR90053 300 1.65 1.80 1.51 1 1/2X1 1/4 CR90054 300 1.82 1.88 1.62 2X1/2 CR90061 300 1.49 1.88 2.00 2X3/4 CR90062 300 1.60 1.97 2.05 2X1 CR90063 300 1.73 2.02 2.10 2X1 1/4 CR90064 1 300 1 1.90 2.10 2.30 2X1 1/2 CR90065 1 300 1 2.02 1 2.16 1 2.60 Page 38 CAST IRON iISTRAIGHT TEE NOMINAL SIZE (INCH) EM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 C1333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 1 CT555 1 300 1.94 1.94 1 2.51 2 CT666 300 2.25 2.25 3.96 2 1/2 CT777 300 2.70 2.70 6.45 CAST IIRON L DEGREE 1!:Ii1'A' NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSIONS WEIGHT EACH PIECE - A - B 1 CR45033 300 1.12 1.12 0.84 1114 CR45044 300 1.29 1.29 1.40 11/2 CiTS-O551 300 1.43 1.43 1.80 2 CR45066 300 1.68 1.68 2.79 Ll CAST IRON PLUGS NOMINAL SIZE (INCH) I ITEM CODE MAX. WORKING P.S.I. IDIMENSION I WEIGHT' EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPL004 300 1.36 0.44 1 1/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 C.I. THREADED FITTINGS FITTINGS (L)iviciou ofStarPipe Products LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 J% IIRON CROSS NOMINAL SIZE (INCH) IT CODE # MAX. WORKING P.S.I. DIM BSIONS WBGK EACH PIECE A B 1 CX033 300 1.501 1.50 1.54 11/4 CX044 300 1.75 1 1.75 2.40 11/2 CX055 300 1.94 1 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 112X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 t'-'IIRON REDUCING 1 NOMINAL SIZE (INCH) ITEM CODE # MAX. ' WORKING P.S.I. DIM alSIONS 'WBGIrT I EACH PIECE A B C 1X1X1/2 CT331 300 --TN- 1.26 1.36 0.95 1X1X3/4 CT332 300 TT 1.37 1.45 1.10 1X1/2X1 CT313 300 13 1.36 1.50 1.08 1X3/4X1 CT323 300 1.45 1.50 1.18 1X1X1 1/4 CT334 300 T7 1.67 1.58 1.52 1X1X1 1/2 CT335 300 -T-80 -1-.80 1.65 1773 1 114X1X112 CT431 300 14 1.26 1.53 1.17 1 114X1X3/4 CT432 300 1.37 1.62 1.38 1 1/4X1X1 CT433 300 T3W 1.50 1.57 --f.-47-- 1 1/4X1X1 114 CT434 300 .75 1.67 .75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 -1 - 1.82 2.05 1 114X1 1/4X1/2 Cr441 300 1.34 -1-.W- 1.53 ---T.37 I 1/4X1 114X3/4 CT442 300 1.45 i43 1.62 1.54 1 1/4X1 1/4X1 CT 443 300 1.58 1.58 1.67 -7.0- 1 114X1 114X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 114X1 114X2 C1446 300 2.10 2.10 2.55 1 112X1 X112 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 C1532 300 1.52 1.37 17 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.65 1 1/271X1 1/4 CT534 300 1.82 1767 Tä 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 2.30 1 1/2X1 1/4X1/2 C1541 300 1.41 1.34 138 1 112X1 1/4X314 CT542 300 1.52 1.45 t7 1.72 1 1/2X1 1/4X1 C1543 300 1.65 1 1.58 TW 1.85 1 1/20 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 C1545 300 1.94 1.88 1• 2.49- 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 - 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 C1554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 C1556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 C1663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 1 2.02 2.16 3.72 2x2x2 1/2 C1667 300 1 2.60 1 2.60 1 2.39 1 5.10 Page 39 March 14, 2008 Sprinkler 41a The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar riumer 2-1946-SA and iv1/ Volume ]b ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40 170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C 19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B, Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com For TeflonO Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy' = F, White Polyester = M-NV, Black Polyester = M-/B, and Black Teflon = N Temperature Suffix (°F/°C): 135°/570 = A, 1550/68° = B, 175°I79° = 0, 2000/930 = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 ¶168 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A 1/2 ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fo.±s Protective Sprinkler Cap 10896 Figure 1: Standard Sprinkler Wrench 10896W/B March 14, 2008 Sprinkler 41c MICROFAST® AND 'sJ I FJ I1G I:II[u'YM MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269945-4495 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 00) Red Intermediate 175 'F (79 'C) 150 'F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 'F (65 'C) Green High 286 'F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. "I - Sprinkler wrench 12144V/B** for installing coated and/or recessed pendent sprinklers with protective cups. w*A 1/2' ratchet is required (not available from Viking). Carefully slide the wrench sideways around the protective cup ensuring engage- ment with the 'sprinkler wrench flats, Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41 d March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN j K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT I BSP Lu.s.methc2j Inches mm cULus4 FM5 NYC' VdS LPCB I Standard Orifice 06662B I VK302 1/2" 115 mm 5.6 80.6_] 2-1/4" 58 1 AiX, BIY I A3X, 133Y A%B1Y A3 A3X, 133Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4" 20 mm J80 115.2 2-3/8" 60 AiX, B1Y A2X, 132Y AiX, BIY -- A3X C313 -- 12104 VK352 3/4" 20 mm 8.0 115.2 f2-1/4" 58 -- -- -- (33 - -- -- 06765B VK352 1/2" 15_mmj8.0 115.2 _2-3/8" 60 A1X,B1Y - AiX,B1Y A3 -- - -- Small Orifice' 0671813Jk329 1/2" 15 mm 28 40.3 2-3/16" 56 A1X,B1fA2X A1x,B1Y -- -- -- -- 06720B1° VK331 1/2" 15 mm 42 60.5 2-1/4" 58 AiX,BiY -- Aix,BiY -- -- - -- 06932B VK331 -- 10 mm 42 60.5 2-3/8" 60 -- -- -- A3 -- G214 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X,131Y - Aix -- ________ Maximum 250 PSI (17 bar) WWP Small Orifice' 1229010 VK342 1/2" 1 15 mm 1 2.8 1 40.3 2-3/16" 56 _Aix,BiY _-_ Aix Approved Temperature Ratings Approved Escutcheons A 135°F (57 "C) 155°F (68 °C), 175 °F (79 °C), 200°F (93 °C), Approved Finishes x - Standard surface-mounted escutcheon or B - 135 °F (57 0c, 155°F (68 °C), 175 "F (79'C), and 200 °F (93 °C) 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F ester'.-, Black Polyester78, and Black Escutcheon 12 (141 °C) Teflon®7 Y - Standard surface-mounted escutcheon or D - 135 "F (57 °C), 155 "F (68 °C), 175 °F (79 °C), and 286 "F 2 - Brass and Chrome-Enloy® the Viking Microfast® Model F-i Adjustable (141 °C) 3-Brass,Chrome-Enloy®, White Polyester8, Escutcheon 12 or recessed with the Viking - 155 oF (68 :g F (79 :' and 200 oF Q, and 286 4O) and Black Polyester' Micromatic® Model E-i or E-2 Recessed G -155°F(68°C) I Escutcheon Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. ° Other colors are available on request with the same Listings and Approvals as the standard colors. ° Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 10The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12 The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13 CE Certified, Standard EN 12259-1, EC of conformity 0832-CPD-2001 and 0832-CPD-2003. -certificate 14 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-401 30 and 0786-CPD-401 70. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008. March 14, 2008 Sprinkler 41e The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com cULus Listing Requirements: Microfast® and MIcrofastHP5 Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Anroval Reouirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/8" 2-1/2" (63.5 rim) maximum (54 ) 1/2' <15 ____ NPT -f 2-1/4" 1-5/8' (58 mm) (41 mm) L Pendent Sprinkler 06662B (VK302) 1-3/4" (44.5 mm) Instoflec1 with ci standard 1/8" surface- mounted escutcheon. ft) (I1J) L_J 2" II UI 1-1/2" (381 mm) (50.8 mm) ) fl/ Minimum Maximum L Ins-tolled with ci Microfast Model F-i Adjustable Escutcheon I Figure 3: Sprinkler VK302 Dimensions with a Standard, Escutcheon and the Model F-I Adjustable Escutcheon Sprinkler 41f March 14, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com 2-1/8" Ceiling Opening Size 2-1/8" -a (54 rim) 2-5/16" (58.7 rim) minimum (54 rim) 2-1/2" (63,5 rim) maximum 1-3/4" Minimum 1-1/8" (28.6 mm) (44,5 mm) Maximum Installed with a Micromatic Model E-1 Recessed Escutcheon 2" \jK 33 )j/1_1/8" (28,6 rim) (50,8 mm) \j2 iJJ Minimum Maximum •I III _________ Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE - Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) August 13, 2009 Sprinkler 54a The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD-40249 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water Viking Technical Data may be found on working pressures ranging from the minimum 7 psi (0.5 bar) up to The Viking Corporation's Web site at 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) http:/Iwww.vikinggroupinc.com. sprinklers can be identified by locating "250" stamped on the deflec- The Web site may include a more recent tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2' (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65 "F (-55 "C) Patents Pending *cuLus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetnc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_i 03005 Replaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). Sprinkler 54b August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 2000/930 = E For example, sprinkler VK463 with a 155 °F/68 °C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16' diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/5W1634, Painted Black = M-/SW1007 Temperature Suffix (°FI°C): 135°/57° UL (139°/59° FM) =A, 165°/74° = C For example, cover 13504 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) —Requires a 'A" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. August 13, 2009 Sprinkler 54c The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Sprinkler ' NPT ' Nominal Maximum Listings and Approvals4 Base SIN Thread Size K-Factor Water Working (Refer also to Design Criteria on page 54d.) Part No.' Inch j mm U.S. ImetIic2 Pressure clJLus5 I FM NYC6 VdS LPCB I CE Standard Response Applications 13503A ] VK462 1/2" 15 5.6 80.6 175 psi (12 bar) -- AU1,BX1 -- AY1,CZ1 - -- 14697A j_VK462 1/2" 15 5.6 80.6 1 175 psi (12 bar) -- - -- - AV2, BW2 AV2, BW27 Quick Response Applications 13503A VK462 1/2" 15 80.6 175 psi (12 bar) AV1, BX1 - AV1, BW1 - - AY2, CZ28 14697A VK462 1/2" 15 t5. 80.6 175 psi (12 bar) AV1, BX1 -- AV1, BW1 - - - 13667A VK463 1/2" 15 80.6 250 psi (17.2 bar)3 AV1, BX1 -- AV1, BW1 -- -- -- Cover Plate Assembly Temperature Ratings' U -135°F (57 °C) cULus Listed cover 135041, 136421 (large diameter), Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings or 153941 (square cover plate) FM Approved as 139 °F (59 °C) 1 - Polished Chrome, Brushed Chrome, A 155F (68 C) V - 135 OF (57 °C) cULus Listed cover 135041 or 136421 (large diameter) Bright Brass, Antique Brass, °C) W- 165°F (74 cover 135041 or 136421 (large diameter) Brushed Brass, Brushed Copper, B - 175 OF (79 C) and 200 OF (93 C) x - 165 OF (74 °C) cover 135041, 136421 (large diameter), or 153941 Painted White, Painted Ivory, or C - 200 OF (93 C) (square cover plate) Painted Black V - 135 OF (57 °C) cover 135041 2 - Polished Chrome, Painted White Z - 165 OF (74 °C) cover 135041 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 (( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. The 135/139 OF cover has an orange label. The 165 OF cover has a white label. 10Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 OF (68 °C) 100 OF (38 °C) 135 1F(57C)cULus Red Intermediate 175 OF (79 °C) 150 OF (65 °C) 165 OF (74 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) 165 OF (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler 54d August 13, 2009 MIRAGE® STANDARD AND QR CONCEALED PENDENT NIIQNG* SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com cULus Listina Reauiremants: Mirage® Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 rn). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Aoorovat Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 or QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. CUSi NNW ((0)) Identifico:tion of Custom Paint Color All custom color painted cover plates wilt have an identifying label affixed to the inside of the cover that indicates custom color and will, have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint Color for Concealed Covers 00 NOT PAINT 3-5/16" (84,1 nn) Figure 2: Square Cover Assembly 15394 2-1/4" (57.2 mm) diameter opening Is required in the ceiling. 11 op 45e Sprinkler Frame Arms Sprinkler Wrench Flat Sprinkler Wrench (Port No 4047 is shown) NEVER install the sprinkler by applying the installation wrench across the frame arms DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031, August 13, 2009 Sprinkler 54e The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A 1/2" ratchet s required (not ,liable from Viking) Step 1: Carefully slide the wrench sideways around the deflector and pins Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. DO NOT apply more than 25 ft. lbs, of torquie. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Correct Use of Wrenches - 1/2" (15 mm) NPT 2-9/16" 2-1/16" (55 mm) maximum Minimum _ 1 II 2-3/4" (70 mm) or 3-5/16" (84.1 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16" (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation January 27, 2012 Sprinkler 136g The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Cleanroom Cover Assembly 136424CR is a low-profile cover intended for-use in cleanroom environments with Viking Mirages Concealed Pendent Sprinkler VK462, MRI Sprinkler VK462 (listed as quick response), or Sprinkler VK464 (listed as standard re- sponse for this application). Note: Adding the seal does NOT change sprinklers VK462 QR listing. The silicone cover gasket is pre-assembled with the concealed cover for an accept- able sprinkler seal for use in a cleanroom or clean zone. The cover assembly is installed flush with the ceiling to provide a smooth appearance, and is available in several stan- dard decorative finishes to meet design requirements. Viking concealed cover plate assemblies may also be custom ordered with any color by any paint manufacturer. The low-profile cover assembly is designed with a threaded adapter and provides up to 1,4" (12.7 mm) of vertical adjustment. The two-piece sprinkler and cover plate design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing tem- porary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV Refer to the Approval Chart and Design Criteria on page 136i for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2009. Refer to the appropriate sprinkler technical page for sprinkler specifications. Material Standards: Cover Plate: Copper UNS-C 11000 Base: Brass UNS-C26000 or UNS-C26800 Gasket: Silicone Springs: Nickel Alloy Solder: Eutectic Viking Technical Data may be found on The Viking Corporation's Web site at http:llwww.vikinggroupinc.com. The Web site may Include a more recent edition of this Technical Data Page. Ordering Information: (Also refer to the current Viking price list.) Cleanroom Sprinkler Cover Assembly: Base Part No. 13642-/CR (3-5/16" diameter) for Sprinkler VK462, VK464, and MRI Sprinkler VK462. Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135°F (57 °C) =A, 165°F (74 °C) = C For example, cover 13642-/CR with a Painted White finish and a 165 °F (74 °C) temperature rating = 13642MC1W/CR. Available Cover Plate Finishes And Temperature Ratings: Refer to Table 1. INSTALLATION A. After installation of MirageO Concealed Pendent Sprinkler VK462 or VK464, testing of the system, repairing of all leaks, and installation and painting of the ceiling, the concealed sprinkler cover plate assembly may be attached. Remove the plastic protective cap from the sprinkler. Remove the cover plate assembly from the protective box, taking care not to damage the assembly. Gently place the base of the cover plate assembly over the sprinkler protruding through the 2-1/4" (57.2 mm) ceiling opening. Carefully push the cover plate assembly onto the sprinkler until the cover plate flange fits tightly against the ceiling surface. The maximum adjustment available is %" (12.7 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler nipple. B. DISASSEMBLY: Cover plates can be removed by gently unthreading them from the sprinkler body. C. RE-ASSEMBLY: The push-on feature of these cover plate assemblies allows easy installation of the cover plates. Gently place the base of the cover plate assembly over the sprinkler. Push the cover plate assembly onto the sprinkler until the cover plate flange fits tightly against the surface of the ceiling. Form No. F_022409 Replaces page 136g-j, dated June 24, 2011. (Added Sprinkler VK464.) Sprinkler 136h January 27, 2012 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to ihatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Concealed Sprinklers VK462 and VK464 and Cleanroom Cover Assemblies are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. CUS1â4 Identification of Custom Paint Color All custom color' painted cover plates will have an identifying label affixed to the inside of the cover- that indicates custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint Color- Concealed Covers TABLE 1: AVAILABLE COVER PLATE ASSEMBLY TEMPERATURE RATINGS AND FINISHES ILI l o L 10I L -. -I - Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow 136424CR Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Step 1: Carefully slide the wrench sideways around the deflector and pins. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler & Adapter Assembly (Protective Cap Is removed for installation--use Wrench 140310) NEVER Install the sprinkler by applying the Installation wrench across the frame arms. DO NOT overtlghten. Use only the designated sprinkler wrench. liking Part Number 14047V/D or 14031. DO NOT apply more than 25 ft. tbs. F torque. A leak-tight seal should be :hieveci by turning the sprinkler clock- e 1 to 1-1/2 turns beyond finger tight. 2-1/4' (57.2 rlm)—\ L diameter opening is required in the ceiling. J...._ Sprinkler Wrench (Part No, O47V/B)Kw is shown) 1/2' ratchet required (not ible from Viking), Sprinkler Frame Arms Sprinkler Wrench Fiat r January 27, 2012 Sprinkler 1361 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Size . Nominal I Maximum MWater Listings and Approvals3 Sprinkler Base NPT Thread (Refer also to Design Criteria below and SIN K-Factor Working Pressure I on the applicable sprinkler data page.) Pa Number' L Inch mm U.S. metric2 psi bar cULus' FM NYC Quick Response Applications 13503A I VK462 I 1/2" I 15 I 5.6 I 80.6 175 I 12 AWl, BXI -- I - 15480A VK462 (MRI) 1/2" J 15 5.6 J 80.6 I 175 J 12 AW1,BX1 Standard Response Applications 13614A VK464 20 1 8.0 1 115.2 1 175 12 AWl, BXI -- - Sprinkler Temperature Ratings I Cover Plate Assembly Temperature Ratings' Finishes of the 1w Cover Plate Assemble I A - 155 °F (68 °C) - 135 °F (57 °C) cleanroom cover assembly 13642-A/CR1 B - 175 °F (79°C) and 200 °F (93 °C) X - 165 °F (74 °C) cleanroom cover assembly 13642-C/CR1 1 - Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. ltThen pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3lhis chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 'I Listed by Underwriter's Laboratories for use in the U.S. and Canada. The 135 °F (57 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 6 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. cULus Listing Requirements: Viking Cleanroom Sprinkler Cover Assembly 136424CR is cULus Listed for use with the Mirage® Concealed Pendent Sprinklers VK462 (QR), VK464 (SR), and MRI Sprinkler VK462 (QR) in a cleanroom or clean zone for installation in accordance with the latest edition of NFPA 13 for cleanrooms when the following conditions are met: Wet systems shall be provided throughout the facility containing cleanrooms and clean zones. Sprinklers shall be installed in the plenum and interstitial space above cleanrooms and shall be hydraulically designed for a density of 0.2 gpm (8.15 Limin m2) over a design area of 3000 ft2 (278.8 m2). Sprinklers installed in duct systems shall be hydraulically designed for a density of 0.5 gpm (1.9 Limin) over an area derived by multiplying the distance between the sprinklers in a horizontal duct by the width of the duct. Minimum discharge shall be 20 gpm (76 L/min) per sprinkler from the five (5) hydraulically most remote sprinklers. Sprinklers installed in ductwork shall be spaced a maximum of 20 ft (6.1 m) apart horizontally and 12 ft (3.7 m) apart vertically. A separate indicating control valve shall be provided for sprinklers installed in ductwork. The sprinklers shall be acessible for periodic inspection and maintenance. NOTE: Sprinkler VK464 is cULus Listed as a standard response sprinkler when using Cleanroom Sprinkler Cover Assembly 13642-A/CR. However, it is listed as a quick response sprinkler as indicated on sprinkler technical data page 55a-e when using Cover Assembly 13642 (for non-cleanroom IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the sprinkler data page (54a-e for Sprinkler VK462, 54p-t for MRI Sprinkler VK462, or 55a-e for VK464), and page QRI -3 or SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. V Sprinkler 136j January 27, 2012 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com NPT 2-5/8" 2-1/8' 2-3/16" c:riw 1 (67 mm) (54 mm) (56 mm) L Maximum I 1- -R 11 . Minimum r1 1 fl— I .1t Gasket IOU 90r Cover Ass emblyY Note Upon sprinkler activation, the deflector descends to approximately 13/16" (20,6 mm) below the sprinkler body. Figure 3: Sprinkler VK462 Dimensions and Cover Installation 3/4' (20 mm) - NPT (57,2mm) L 2-11/16" 2-3/16' (68 mm) (56 mm) —1 Maximum - Minimum Gasket r°' - 3-5/16" Cover AssemblyY (84,1 mm) Note Upon sprinkler activation, the deflector descends to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler VK464 Dimensions and Cover Installation Form No. F_022409 Replaces page 136g-j, dated June 24, 2011. (Added Sprinkler VK464.) C@ Us USTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed gfliy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com cus usno Fig. 78 - All Steel Ceiling Plate Size Range - 3/8" rod Material - Carbon Steel Features - Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Patent #5,702,077 UL Listed Fastener Table Pipe Size Oty Fastener Type Material 1/2-2 21/2 -4 1/2-2 2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw 1/4 x 1½ wood screws' 1/4 x 1 tek screws Wood Wood Metal (18 gauge) 1/2-2 1/2 -2 2 2 #14 x 11/4 A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood thru 5/8' gyp board * No pre-drilling Dimensions • Weights Pipe Size A Max. Rec. Approx. B C D E Load Lbs.* WtJ100 1/2-2 5 - 6 3 21/8 11/8 5/16 3/8 Consult factory for data 150 15 * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.780.5260 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System ( FIG. 98 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 -All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1½ 13800 510 M OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599. FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 2" Fig. 200 - "Trimlifle" Fig. 200R (Import) - Adjustable Band Hanger "Trimline" Adjustable Band w/Retainer Ring Hanger C@ US USIIO Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8'). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or10mm 31/8 400 11 3/4 3/8 8mm 0r10rnm 31/8 21h 400 11 1 3/8 8mm or 10mm 33/8 25/s 400 12 11/4 3/8 8mm or 10mm 1 33/4 27/8 400 13 1112 3/8 8mm or 10mm 3/s 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/5 41/8 600 27 3 3/8 10mm 57/5 4 600 29 3½ 3/8 10mm 7 /8 51/4 600 34 4 3/8 10mm 73A 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.7375599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com D Not less than 2' nominal wdth Wood Flooring 11-lf2'l Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. a 9 Wood 114' 8002957 GST 100 1/4 x11" 25 125 1/4' 8003957 GST 200 1/4x2' 1760 (Fir) 25 125 #14 Black Nut Driver Part #8113910 1/4 800495 GST 3 1/4 x 2060 (F)) 25 12] 3/8 8006957 GST .75 1/4x 3/4' 564 (3/4' Ply) 25 125 318 8007957 GST 10 114x1 210 (71161 OSO) 300 25 125 670 Ply) 3/6' 8008957 GST 20 1/4x2' 1760 (Fir) 850 1475 25 125 !8 8068925 GST2O-SS 1/4x2'_ 1760 iFJy) 850 25 125 1 3/6' 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 3/6' 801W7 GST 30 1!4x8' 2060. (Fir) 1550 1475 2 175 3/8' 8069925 GST30SS 1/4x3' 2060 (Fir) 25 125 3/6 85ll9 5T40 1/4 x4' 285 (Fir) 5 15 3/8' 8012925 GST 60 114x6" 2230 (Fir) 25 125 - 1/2 801395 GST 2 114x2" 179, (Fir) 25 l2 I #14SWRed 1/2 8014925 GST 2.5-380 3/8x2-1/2' 2113 (Fir) 25 125 1/2' BDI6925 1Ax 2275{F7) 25 1251 1/2' 8016925 GST4 114x4" 2180 (Fir) 25 125 f7'65 /STh 71x5 rf - Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. Saves time from traditional methods. Accommodates up to 3 '4" a 12 pitch roof. • Reduces installation cost Allows 17" deflection from vertical. 'Made in the U.S.A SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each fme. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 21 &ueeeiu.s.* !' #144 Black Nut Driver Part # 8113910 LI Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. Not less than? nominal width / (1-Il7) up to 3-1/2" pipe; not loss than 3" (2-1/?) nominal width 4 65" pipe I Minimum 2-V? from bottom for branch lines. Minimum 3" from bottom for main toes. Except= This requirement shall not app to 2" or thicker nailing ships resting on top of steel beams. ii IN Floor Joist - #14 SW Red Nut Driver 1 114" §Q18957 SWG 100 1114.11' 622 /Fir. '' - 251J 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 i: 38 8020957 WG 10 11A x1 622 (Ftr,) jw 25 I 3/8" 8021957 SWG 20 1/4 x2" 1725 (Fir) 1050 25 125 3" 0073925 'SW 20-SS 114x2" 1725 )1 9.50 25 1W1 . 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 [, F/61 925 SW 30 1/4 x .31 1884 (9.) 25 125 Pad #8114910 - Insert the appropriate nut driver into a 3/8 or 112"portable drill Insert the SAMMYS into the #14 (black) nut driver (rVn 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2"or metric all thread rod, boll stock. (The 1t2" requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. - rwo I Lrm Insert the appropriate nut driver into a 3/8" or 1t2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or boll stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purl/n steel. ENT t "N 17, SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.