HomeMy WebLinkAbout1250 CARLSBAD VILLAGE DR; ; FPC2024-0164; PermitIF1Ii 4lii1Zs] il city of Carlsbad CARLSBAD, CA 92008-1949 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2024-0164 Status: Closed - Finaled Applied: 11/08/2024 Issued: 12/20/2024 Finaled Close Out: 02/19/2025 Final Inspection: INSPECTOR: Valdes, Rebecca Robinson, Jarrod Print Date: 02/19/2025 Job Address: 1250 CARLSBAD VILLAGE DR, Permit Type: FIRE-Construction Commercial Parcel #: 1561804600 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: CARLSBAD COLE LIBRARY -FIRE ALARM SYSTEM PANEL REPLACEMENT Applicant: STANDARD ELECTRONICS JESUS LEDEZMA 9340 STEVENS RD SANTEE, CA 92071-2810 (619) 596-9950 FEE AMOUNT - FIRE Plan Resub (3rd&Subsequent Submittal/hr) $176.00 FIRE TI Fire Alarm System $807.00 Total Fees: $983.00 Total Payments To Date: $983.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Ph: (619) 596-9950 September 20, 2024 Fax: (619) 596-8850 Revised November 04, 2024 613W. Main St. El Cajon, CA 92020 C7, CIO UC. #590876 BSISACO #AC01903 UL Installer #S3570-1 StandardElectronics.us SUBMITTAL SHEET PROJECT: Cole Library FA Replacement - 3344 ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET Fire Alarm Control Panel, 198 Points 1 1 SFM# 7165-0559:0502 6808 Silent Knight Remote Annunciator 2 1 SFM# 7165-0559:0502 5860R Silent Knight Dual Path Internet and Cellular Commercial Fire Communicator 3 1 SFM# 7300-1402:0503 TG-7FE-V Telguard 4 1 High Gain Antenna for Cellular Communicator 388-3 DMP 5 1 Cellular Antenna Cable 387-25 DMP 6 1 Fire Alarm Document Storage Box SSU00690 Space Age Addressable Smoke Detector, White 7 64 SFM#7272-0559:0 149 SK-PHOTO-W Silent Knight Addressable Heat Detector, White 8 1 - SFM#7270-0559:0 147 SK-HEAT-ROR-W Silent Knight 6' Base, Flanged for use with analog sensor - White 9 65 SFM#7300- 1653:0109 B300-6 System Sensor Intelligent Air Duct Smoke Detector 10 4 SFM# 3240-0559:0162 SK-DUCT Silent Knight Addressable Pull Station 11 10 SFM#7 150-0559:0161 SK-PULL-DA Silent Knight Addressable Mini-Monitor Module 12 4 SFM#7300-0559:0 155 SK-MINIMON Silent Knight Addressable Relay Module 13 7 SFM#7300-0559:0 155 SK-RELAY Silent Knight 14 1 Supplementary NAC Panel SK-PS10 Honeywell SFM#7315-0559:0522 Ceiling Strobe, 12/24volt, white, multicandela 15 18 SFM#7300-1653:0525 SCWLED System Sensor Wall Strobe, 12/24volt, white, multicandela 16 2 SFM#7300-1653:0525 SWLED System Sensor Wall Horn/Strobe 12/24volt, white, multicandela 17 2 SFM#7 135-1653:0526 P2WLED System Sensor Ceiling Horn/Strobe 12/24volt, white, multicandela 18 10 SFM#7135-1653:0526 PC2WLED System Sensor Replacement Backflow Tamper Switches, Corrosion Resistant rl 2 SFM# 7770-0328:0010 OSYSU-2 CRH Potter Ph: (619) 596-9950 Standard Fax: (619) 5948850 613W. Main St. I, o:cs El Cajon, CA 92020 C7, dO LIC. #590876 Electr UL BSISACO #AC01903 Installer #S3570-1 StandardElectronics.us SUBMITTAL SHEET September 20, 2024 Revised November 04, 2024 PROJECT: Cole Library FA Replacement - 3344 ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 20 2 12 Volt 7 AH Sealed Lead Acid Battery ES7-12 MK Battery 21 1 2 12 VOLT 18 AH Sealed Lead Acid Battery E517-12 MlKBattery Intelligent Fire Alarm Control Panel with Communicator The 6808 features a built-in SLC circuit, four output circuits, dual-Line DACT, powerful software features, and connectivity for up to 17 panels. The 6808 is the latest intelligent addressable FACP (Fire Alarm Control Panel) from Silent Knight and is a direct replacement for the 5808 FACP. The 6808 has one SLC (signaling line circuit) loop for connecting addressable detectors, which can support 99 System Sensor® SK sensors and 99 SK modules or 127 Hochiki® SD devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone tines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available. The 6808 has four onboard output circuits that can be configured as notification outputs or auxiliary power. There are four types of Aux power available: door holder, constant power, resettable power and sounder sync power. The 6808 also has form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. The 6808 supports a variety of devices, including 6860,5860, or 6855 remote annunciators, 5824 serial/parallel printer interface modules (for printing system reports), 5895XL power modules, and SK, SWIFT® wireless, or SD devices. FEATURES AND BENEFITS Complies with UL 864 10th Edition • Four line LCD display with 20 characters per • Connectivity for up to 17 sites Built-in support for up to 99 IDP/SK line • Network card allows copper network detectors and 99 lDP/SK modules or 127 • Built-in USB interface for quick and easy SD SLC devices programming Four output circuits (3 amps max) for NAC • JumpStart® auto programming reduces outputs or auxiliary power installation time Selectable strobe synchronization for • 13 preset notification cadence patterns Amseco®, System Sensor, Wheetock®, and (including ANSI® 3.41) connection with a multi-mode or single- mode fiber connection Programmable date setting for Daylight Savings Time History file with 1,000 event capacity Can be surface or flush-mounted Gentex® devices 250 software zones and 250 output groups for flexible design options Built-in dual phone line, digital alarm communicator/ transmitter (DACT) with IP and optional cellular technologies Allows up to 20 SBUS devices Two programmable relays and one fixed trouble relay Convenient field-upgradeable firmware Supports up to four SWlFlwireless gateways which can foster up to 49 wireless devices each Honeywell DsILEsT. KNIGHT USER INTERFACE LED INDICATORS General Alarm (Red) Supervisory (Yellow) System Trouble (Yellow) System Silenced (Yellow System Power (Green) I 1 •Ji 1] 12-key numeric pad Acknowledge Alarm Silence System Reset F1-F4 Programmable Function Keys PROGRAMMING The 6808 system offers several options to simplify and expedite programming. JumpStart auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on-site access to current system programming. System programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6808: Addressable fire alarm control panel, red COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 5860R: 420 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators can display up to 30 LEDs (15 red and 15 yellow) 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED I/O module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: Serial/Parallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same system. Refer to the Device Compatibility Document and SLC Wiring Manual for more information. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1351F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1901F), white SK-H EAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MlNlMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10-input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PHOTO-T: Photoelectric smoke detector with fixed thermal heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detector with fixed thermal heat (1350F), white SK-PTIR-W: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module SK BASES B21OLP: 6" mounting base B501: 4' Flangeless mounting base B2005: Intelligent sounder base B200S-LF: Low-frequency intelligent sounder base B224RB: Relay base B224Bl: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same system. 5D505-6A8: Addressable 6' base 5D505-6113: Addressable 6' short circuit isolator base 5D505-6RB: Addressable 6' relay base 5D505-6SB: Addressable 6' sounder base SK-BEAM-T: Reflected beam smoke detector with test feature SDSOO-AI M: Addressable input module (switch input) OSI-RI-SK: Reflected beam smoke detector, SK protocol SD500-ANM: Addressable notification module SK-CONTROL: Supervised control module SD500-ARM: Addressable relay module SK-CONTROL-6: Six circuit supervised control module 5D505-DTS-K: Remote test switch/LED indicator for the SK-DUCT: Photoelectric duct smoke detector with extended air 5D505-DUCTR speed range 5D505-DUCT: Addressable Duct Smoke Detector SK-FIRE-CO: Four criteria fire and carbon monoxide detector 5D505-DUCTR: Addressable Duct Detector housing with relay base Page 2 of 4— 351608:D • 5/22/2023 SD505-H EAT: Absolute temperature heat detector. Trip point range from 1350F-150°F (0°C-370C) SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK- PH OTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-H EAT: Wireless, fixed heat detector (135°F) with B50IW base WSK-H EAT-POP: Wireless rate-of-rise heat detector and B50IW base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.farenhyt.com SYSTEM EXPANDERS 5895XL: 6A power supply with six Flexput circuits and two Form C relays 5496: GA NAC power expander with four power-limited output circuits OPTIONAL COMMUNICATORS HWF2A-COM: Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T HWF2V-COM: Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I P -2: Remote reporting via the Internet. Requires a VisorALARM® receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6808 SK-N IC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode PBB: Remote battery box accessory cabinet SK-SCK: Seismic compliance kit to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows®-based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel's USB port using a flash drive. Requires a PC running Microsoft® Windows®. Page 3 of 4— 351608:D • 5/22/2023 6808 TECHNICAL SPECIFICATIONS SYSTEM CAPACITY TEMPERATURE AND HUMIDITY Intelligent Signaling Line Circuits: 1 RANGES Addressable device capacity: 198 (SK) or 127 (SD) Programmable software zones: 250 Output circuits: 4 (expandable) SBUS Devices: 20 (12 annunciators, 8 LED modules) ELECTRICAL AC Power: 120 VAC, 60 Hz, 3.3 A Standby Current: 190 mA Alarm Current: 250 mA output Circuits: Terminal block provides connections for(four Class B or two Class A) NACs or auxiliary power. Power-limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End-of-line resistor: 4.7k ohm, 1/2 watt for Class B NACs Communication Loop: Supervised and power-limited, Class A or Class B, 32VDC, 150mA Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A @ 27.4 VDC (resistive), Form C Battery: Cabinet holds maximum of two 18 AH batteries Battery Charger Capacity: 17-55 AH PHYSICAL Dimensions: 16.4"W x 26.4" H x 4.1" D (41.66cm W x 67.06cm H x 10.41cm D) Weight: 45 lbs. (20.4 kg.) Color: Red This system meets NFPA requirements for operation at 0— 49°C (32— 120°F) and at a relative humidity 93°/c ± 2°/c RH (non- condensing) at 32°C ± 2°C (90°F ± 31F). However, the useful life of the system's standby batteries and the electronic components maybe adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 271C/60 - 80°F NFPA STANDARDS The 6808 complies with the following NFPA 72 FireAlarms Systems requirements: NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72 Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-0559:0502 FDNY: COA# 2023-TMCOAP-001168- PEN L FM Approved Seismic: (CA) VMA-45894-05C Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com 351608 I D 05-23 ©2023 Honeywell International Inc. Honeywell 3 sLLENT. KMGHT 9/27/24,12:57 PM LicenseBMLLlNGLlSTNEW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0559:0502 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURI One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Lisa (203y484-6277 (203) 484-7309 Email:_Iisa.brant@hop'ywell.com DESIGN: Ae- Silent Knight Model 6808, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6808 System Components 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16'WX10"HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 1/2 9/27/24,12:57 PM LicenseBMLLlNGLlSTNEW 120VAC, 60HZ, 3.25A Secondary Operating Power Supply: 24VDC, 750mA, 55Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 2/2 SILENT 5860 Remote Annunciator 1:30 KNIGHT by Honeywell Bring the power to control an InteIIiKnight fire alarm control panel to every area within your facility Now you can operate and program your lntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to twelve 5860s per 5820XL/EVS or 5808 system Install up to eight 5860s per 5700 system Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color 5860R: Red 5860: Gray 5860 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Compatibility The 5860 is compatible with the following FACP's: 5820XL Addressable Fire Control Panel 5820XL-EVS Fire Control Panel with Emergency Voice System 5808 Addressable Fire Control Panel 5700 Addressable Fire Control Panel PN 350224 Rev G © 2014 Honeywell International Inc 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP SBUS 6860 6860 6860 Up to 12 5860s Per IFP-IOOIECS or IFP-I000IECS System Up to Eight 5860$ Per 5700 System Compatible lntelliKnight FACP Listings Ordering Information NFPA72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559:135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America 9/27/24,12:57 PM LicenseBMLLlNGLlSTNEW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0559:0502 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Lisa (203) 484-6277 (203) 484-7309 Email: Iisa.brant@honeywell.com DESIGN: Silent Knight Model 6808, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6808 System Components: 5860 Remote Annunciato 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NiC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10'HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 1/2 9127/24,12:57 PM LicenseBMLLINGLlSTNEW 120VAC, 601-11Z, 3.25A Secondary Operating Power Supply: 24VDC, 750mA, 55Ati INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTES: *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational '7 requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 2/2 DUAL PATH (((i))) INTERNET 5G LTE-M iAAL Id b IN it 13 COMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FE offers two pathways to reliably transmit signals: a wired LAN connection to the Internet and 5G LTE-M cellular. It operates on panel power or via plug-in transformer. PRODUCT FEATURES P Dual communication paths - If the Internet connection is interrupted or the LAN goes down, always-on 5G cellular will immediately step in. I- Powers directly from the fire panel's 12V/24V auxiliary power supply or via plug-in transformer (included). I- Uses LTE-M bands for 4G and 5G network compatibility, better in-building penetration, and longest product life. I Interfaces with panel over a single DACT connection for universal compatibility (use TG-PEM accessory when panel has no DACT). Telguard communicators are compatible with more alarm formats than any other brand. The signal will reliably get to the central station. The world is changing. Copper POTS lines are disappearing, and calls are delivered over the Internet. This is a perfect example of where the TG-7FE steps in. Eliminate all Telco lines and run an Ethernet cable from the TG-7FE to the premises LAN for alarm signal delivery. And, to be sure signals get through to the central station you choose, the TG-7FE instantly falls over to reliable cellular service any time it's needed. Telguard puts nearly four decades of alarm communications expertise into every UL Listed communicator. You stay in control, with highly configurable options that meet your needs and the requirements of your AHJ. UL Lifi1ijXT& andjFi)J 864 Gommercial Fe 1610 G''t Station ULC Litings (AT&T c5lV) S559 GommerI Fire S3Jie2ciI Bugy Cetifications GaUf3iT_Sta e Fire jilal UEDNYIapproval penn rsififions 4OmA 12VEC iII'Accessories 'onsumption I5%'11D1ifl 18VC 9r1r89crn) Tsmi1ii0mA @ • 2dbrm @ 12Y.QC arying lengths o antenãt3ies .ornpatiTFFts • EMM ntcs (P _ rvkntenna CHOOSE THE COMMUNICATOR THAT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. 12V; 24V needs TG-PEM TG-7UBL For the most current product specifications and iJL Listings visit teiguard.com/tg-7fe. in Canada, cellular data may be carried by Rogers, Bell, Talus or SaskTei. 800.229.2326 1 3225 Cumberland Blvd SE • Suite 300 'Atlanta, GA 30339 • USA I telguard.com ©2021 Telguard I Telguard and the Teiguard Logo are registered trademarks of Teiuiar Corporation. I Teiuiar is a business unit of AMETEK, inc. All Rights Reserved. AMETEK 10202 1R,0 9/17/24,4:22 PM LicenseBMLLINGLISTNEW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM NX LISTING SERVICE LISTING No.: 7300-1402:0503 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP. 335 Cumberland Blvd, NE, Suite 300, Atlanta, GA, 30339 Contact: Stewart ean (800) 229-2326 (678) 945-1651 Email:_sean.st,zart@ametek.com DESIGN: Model TG-7FE Digital Cellular Radio Alarm Transmission Device. Models are suffixed with -A for AT&T networks and -V for Verizon networks. Product is used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. The control unit and TG-7FE communicator must be installed in the same room. Intended for indoor and dry locations. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 120 VAC; 12or24VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as digital cellular radio alarm tranmission device for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: Burglary and other non-fire functions were not examined. 9-22-21 VWW This listing is based upon technical data submitted by the applicant OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an j endorsement or recommendation of the item listed. This listing should not be used to verify correct operational J' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/06/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division 1/2 9/17/24,4:22 PM LicenseBMLLINGLISTNEW Page 1 of 1 2/2 SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 722013 7.2.1). loll Space Age Electronics, Inc. 'S09 001 NFPA COMPANY .1723 Toll Free .0966 Local ade '508'485.4740 Fax Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface _— Requires Standard USB-B Connector Properly Information MtnleotteRequired s000nnnntatlon (SIG-FUN) n. o a.ysesenpr Certifications and Approvals 16.1 System Installation Connector sFvvnffl.n..IeM sn.thnnl.ruoom.,.snsn0000s,00 5000 .100000050 0.1.0 nroom005r.rn.nv.wsoaaos0501.nsosose 50". POn000 _______________ lentm055nlev.Fvn o5 agososm______ in. 55510500000500bn.dvn0.dn.0510005.e.uve.anv1.m.I,n.nnn 16.5 Avthotity Having J0risdlotivn rli00l5i0rot.i OnIon. 5010511 kd.l000.10.1st0000Ii Vovmr.tnsi.reos1005n.pnoe.000a Nrpvmlviithv505n.5 0000nti.ai.osvan00000.sns0050osov.nv.n.1re00a712 P05.00.0, _____________ t000e0050l.005000n0000ll.soethnnelit.,n,00iov morn______ II Equipment lnlo,nlalton Is 50050 lostoOti 00e055 00048&i023 osesi...vsn LT10644 600.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description 88U00689 System Record Documents Cabinet RED Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SSUOO69O Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0584 LT10641 Rev.A 2/2 > SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lntelliKnight Fire Alarm Control Panels (FACPs). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161. Desçli ption SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features Sleek, low-profile design Base included Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the SK-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 VDC Standby Current: 300 IJA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 320 - 120°F (0°C - 49°C) SK-Photo-T: 32° - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) SK-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal SK-Photo (Base included) Compatibility The SK-Photo and SK-Photo-T are compatible with the following lntelliKnight FACPs: 5700 5808 5820XL 5K-Photo and SK-Photo-T are compatible with the following detector bases: B21OLP (included) 6" base B501 2 wire base B501BHT-2 Temporal base B224RB Relay base B224B1 Isolator base B501BH-2 Sounder base SILENT KNIGHT yHnl Model SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B2IOLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. W11$n9 $K-Se&v I$r MoInu Nom D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA )IG1JT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject FORM# 350118 Rev A, to change without notice. For more information, contact Silent Knight 12 © 2009 Honeywell International Inc. by Hpn%qNefl Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com ..,, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL 1Ii.iI FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7272-0559:0149 PARENT LISTING No.: 7272-0028:0206 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITY One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa 2034846105 Email: lisa.branthoneyweIl.com DESIGN: Models lDP-PHOTO, lDPPHOTOR*, I DP-PHOTO-T, I DP-ACCLIMATE, SK- PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 3242- 1653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTES: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 02-01-10 fm Page 1 of .,......,. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational I' requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/15/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 D SILENT KNIGHT ® by Honeywell SK-Heat, SK-Heat-HT and SK-Heat-ROR Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight lntelliKnight series Fire Alarm Control Panels (FACPs). lntelliKnight heat detectors are an essential component in virtually any lntelliKnight installation. The lntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description SK-Heat, SK-Heat-HT and SK- Heat-ROR are intelligent sensors that utilize a state-of-the art thermistor sensing circuit for fast response. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Heat is a fixed temperature sensor that uses a thermistor sensing circuit to produce 135°F (57°C) fixed temperature alarm. SK-Heat-HT is a variable high temperature detector that provides high temperature detection at 135°F - 190°F. (57°C - 88°C) SK-Heat-ROR is a rate-of-rise temperature sensor with 135°F (57°C) fixed temperature alarm Features Reliable analog communications for trouble-free operation Age resistant polymer housing Innovative thermistor sensing circuit Superior EMI resistance for reliability Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate maintenance is required Plug-in mounting provides ease of installation Optional remote LED annunciator (System Sensor® PN RAIOOZ) Tamper-proof feature available on mounting bases Rotary address switches for fast installation UL Listed Specifications Physical Height: 2.0" (51 mm) Diameter: 6.1" (155 mm)installed in B21OLP base Shipping Weight: 4.8 oz (137 g) Electrical Operating Voltage: 15 to 32 Volts DC Peak Standby Current: 300pA @ 24 VDC LED Current: 6.5 mA@ 24 VDC Environmental Operating Temperature SK-Heat & SK-Heat-ROR: -4° - 100°F (-20°C— 38°C) SK-Heat-HI: -41- 150°F (-20°C - 66°C) Humidity: 10% - 93% noncondensing Thermal Ratings SK-Heat: Fixed temperature alarm 135°F (57°C) SK-Heat (base included) 5K-Heat-HI: High temperature heat sensor 135°F - 190°F (57°C - 88°C) SK-Heat-ROR: Rate-of-rise detection 150F/mm (8.31C/mm) Compatibility The SK-Heat-HT and SK-Heat- ROR are compatible with the following lntelliKnight FACP's: 5820XL 5805 5700 The SK-Heat is compatible with the following lntelliKnight FACP's: 5820XL 5808 5700 5600 (Rev 2.0 or higher) The SK-Heat, SK-Heat-HT and SK- Heat-ROR are compatible with the following detector bases: B2IOLP 6" base (included) B501 2 wire base B224B1 Isolator base B224RB Relay base B200SR Sounder base Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be 132101-P. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Wiring SK-Series Detector Mounting Bases Accessories RA100Z - Remote LED Annunciator. RMK400 - Recessed Mounting Kit. Provides low profile for use with B501. XR213 - Detector Removal Tool. A removal and re- placement tool for SK plug-in detectors. Includes the T55-127-000. M02-04-01 - Replacement Test Magnet. M02-09-00 - Test Magnet with Telescoping Handle. XP-4 - Extension Pole for XR2B. Extends from 5 - 15 ft. T55-127-000 - Detector Removal Head. BCK-200B - Black Detector Kit. For SK-series detectors. * Unless otherwise noted, specifications apply to all SK thermal detectors. KTT' This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SIL ENT L keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350120 Rev. D subject to change without notice. For more information, contact Silent Knight © 2011 Honeywell International Inc. by Honeywell 12 Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION irTI OFFICE OF THE STATE FIRE MARSHAL IJA1 FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7270-0559:0147 PARENT LISTING No.: 7270-0028:0196 CATEGORY: 7270 - HEAT DETECTOR LISTEE: SILENT KNIGHT4'CURITY One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Xisa 2034846105 Email: lisa.bft@honeyweIl.com DESIGN: / Models IØ-HEAT and SK-HEAT* (fixed temperature), IDP-HEAT-ROR,IDP-HEAT-HT, SKHEATROR*, and SKHEAT.HT*(fixed temperature with Rate-of-Rise) electronic heal detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 135°F fixed temperature for Models IDP-HEAT, IDP-HEAT-ROR, SK-HEAV and SK- HEATROR* 190°F fixed temperature for Model IDP-HEAT-HT and SK-HEAT-HT INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with *Iistees separately listed compatible base and fire alarm control units. Refer to listee's Installation Instructions Manual for details. NOTES: *Rev. 07-14-09 fm Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I I OFFICE OF THE STATE FIRE MARSHAL I I FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/15/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 INTELLIGENT BASES Standard, Relay, Isolator, Sounder, and Low Frequency Sounder Bases To meet local code and application requirements, Gamewell-FCI® offers standard 4" and 6" bases, as well as specialty base designs including relay, isolator, sounder and low frequency / - sounder bases that are UL listed for low frequency operation and comply with N FPA 72 ( ,4' "? \ ( i • \ requirements for sleeping spaces for the new Gamewell-FCI Series of addressable detectors 1 ) • as well as previous generations. The standard 4" and 6' bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and —), and remote annunciator B300-6 Standard 6" B200S-WH Sounder connections. Communication takes place over the power (+ and -) lines. The 4" base offers a Base (White) Base (White) compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface- mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. 41 Relay bases (B224RB-WH/B224RB-IV) provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 B501-WHITE Flangeless 6501-BL Flangeless milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin 4" Base (White) 4" Base (Black) headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224Bl-WH/B224B1-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent Studies show that a lower frequency, centered around 520 Hz, is the most idealto wake sleeping occupants, even those with mild to severe hearing loss. FEATURES AND BENEFITS Bases enable quick and secure detector • Standard white color with ivory and black • Sounder bases both UL268 and UL464 plug-in SEMS Screws provide easy wiring connection UL 268 compliant Support for 12-24AWG provides options Mechanical locking feature restricts removal of attached sensor head Specialty Base Features: Pre-wired mounting plate simplifies installation Application driven feature sets compliant installation flexibility Multiple base formats meet application requirements Honeywell The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/ B224RB-IV: Ivory, relay base B200S-LF-WH/B200S-LF-IV) adopt the same address as the B224B1-WH: White, isolator detector base detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder - or a group of sounders - to activate. The command set from the FACP can be tailored to multiple event- driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal - along with other System Sensor AV appliances - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200SR sounder and LF sounder bases (B200SR-WH/ 8200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal or Continuous) through ajumper. PRODUCT LINE INFORMATION INTELLIGENT BASES -IV" suffix indicates Ivory color model. "-BL" suffix indicates Black color model. "-WH" and "-WHITE" suffix indicates White color model. B2IOLP: Flanged mounted base B21OLPA: Same as B21 listed. B21OLPBPU15< of B2IOLP, contains 10. B3OO-6:ite, 6" base, standard flanged low-profile mounting base B224B1-IV: Ivory isolator detector base B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti® protocol B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti® protocol B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +1- 10°/o with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz '-I- 100/0 with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone; Intended for retrofit applications B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone; Intended for retrofit applications B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement; intended for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applications. MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300: White, replacement flange for B2IOLP, B300-6 base B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. TR300-IV: Ivory, replacement flange for B2IOLP, B300-6-IV base B501-WHITE: White, 4" standard European flangeless mounting RAIOOZ: Remote LED annunciator, 3 - 32 VDC, mounts to a U.S. base. UL/ULC listed single-gang electrical box; For use with B501 and B300-6 B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B501-BL: Black, 4" standard European flangeless mounting base B501-IV: Ivory color, 4" standard European flangeless mounting base B224RB-WH: White, relay base JUNCTION BOX SELECTION GUIDE Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Square 4.0" Square with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No 6300-6 Yes No Yes Yes Yes Yes No No No No B22481, B224R6 Yes Yes Yes Yes Yes Yes No No No No Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Applies to all model variants "BL", "-LE", "-IV", "-WH", and "-WHITE". See Product Line Information for detailed model description. Page 2 of 3 — 902 1-60540:K • 7/8/2019 M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 INTELLIGENT BASES TECHNICAL SPECIFICATIONS ELECTRICAL For B300-6 Series bases: Operating voltage: 15 to 32 VDC Standby current: 170 p4 maximum For B501 Series bases: Operating voltage: 15 to 32 VDC Standby current: 150 p4 maximum For B200 Series bases: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 p4 maximum Alarm current for B200S(-IV)(-WH): 35 m4 maximum at high-volume setting 15 mA maximum at low-volume setting Alarm current for B200S-LF(-IV)(-WH) High- volume setting: 70 mA maximum® 33.0 VDC 90 mA maximum @24.0 VDC 140 mA maximum @16.0 VDC Alarm current for B200S-LF(-IV)(-WH) Low- volume setting: 15 mA maximum @ 33.0 VDC 20 mA maximum ® 24.0 VDC 25 mA maximum @ 16.0 VDC Alarm current for B200SR(-IV)(-WH): 35 mA maximum Alarm current for B200SR-LF(-IV)(-WH): 65 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 125 mA maximum @16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) For B224BI, 6224RB (-IV) (-WH) bases: Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 p4 maximum® 24 VDC Set time: (B224RB(-IV)(-WH) only): short delay 60-100 msec; long delay 6-10 seconds Reset time: (B224RB/-IV/-WH only): 20 milliseconds maximum Relay characteristics: (8224RB/-IV/-WH only): two-coil latching relay; one Form-C contact; ratings (UL/C54): 0.94 @ 125 VAC, 0.9 A® 110 VDC, and 3.0 A® 30 VDC PHYSICAL Note: Specifications applies to all modelvariants -BL", "-LF",'-IV", -WH, -WHITE. See Product Line Information for detailed model description. Diameter: B501-WHITE: 4 (10.16 cm) B300-6, B21OLP: 6.1(15.49cm) 8224B1, B224RB: 6.2W (15.748 cm) B200S, B200SR: 6.875W (17.46 cm) Wire gauge: B224B1, B224RB: 14to 24AWG B300-6, B21OLP, B501, B200S, B200SR12to 244WG Temperature range: B224B1, B224RB, B200S, B200SR: 32°F to 120°F (0°C to 49°C) B300-6, B21OLP, B501: -4°F to 150°F (-20°C to 66°C) Humidity range: 10°Io to 93°Io RH, non- condensing System temperature and humidity ranges: This system meets NFPA requirements for oper- ation at 0°C to 49°C (32°F to 1201F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the use- ful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80017). AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S911 FM Approved CSFM: 7300-1653:0109,7300-1653:0126, 7300-1653:0213,7300-1653:0238 Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 wwwgamewell-fci.com 902160540 I K 107/19 02019 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1653:0109 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant, Lisa 2034846105 Email: lisa.brant@honeywell.com/ DESIGN: / Models B401, B401 B, B401I3(401BR, B401BR-750, B401R-750, B402B, B404B, B404BT, B406B, B501, B510'IB, 14506587-002, BSOIBH, B501 BHT, B40IBH, BIIOLP, BIIORLP, B110RLP75Yj112LP, 13114LP, 131I4LPBT, 131 161-P, B2IOLP, B501-BL, B50 IV, "B501-WHITE, B300-6, B300-6-IV, B300-6-IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTES: Formerly 7300-1209:128 *Rev 04-03-18 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational " requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Listing Expires: 06/3012025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 3 SILENT 0 KNIGHT by Honeywell > SK-DUCT Intelligent Air Duct Smoke Detector Detect smoke in air handling systems and air handling equipment with Silent Knight's addressable duct smoke detector The SK-Duct Intelligent air duct smoke detector is used with SK-PhotoR (included) for detecting smoke and products of combustion present in air moving through an HVAC air handling system. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. The duct housing allows for mounting of SK-Relay addressable relay module. Now there's even more power and flexibility available to the IntelliKnight family of products! Description h The Model SK-Duct Air Duct Smoke Detector utilizes photoelectric technology for the detection of smoke. It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial and Industrial applications. The SK-Duct is in a heavy duty gray steel back box with a - nIn,r rn,,nr If fn.,,+. .me nk,n+nr. I,n, .cnn +k,,+ f+e kn+, %.1 %IVVIUI. IL ICa I CO U pi VIJLII I I¼JUOII i3 LU 1W uULO IJULI I square and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily. The unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). Features Versatile mounting options: square or rectangular configuration New Cover tamper signal LED alarm indication and communication on sensor head Detects and limits the spread of smoke Rugged steel back box with clear plastic cover Easy to clean Large terminal connection screws Transparent cover for convenient visual inspection Patented sampling tube installs from front or back of the detector with no tools required Available space within housing to accommodate mounting of relay module UL listed SK-DUCT Specifications Physical (Rectangular): 14.38 in (37 cm) Length; 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square): 7.75 in (19.7cm) Length; 9 in (22.9cm) Width; 2.5 in (6.35cm) Depth Weight: 1.61b (0.73kg) Environmental Operating Temperature: -4°F - 158°F (-20°C - 70°C) Humidity: 0% - 95% (non-condensing) Air Velocity 100 to 4000 ft/mm (0.5 - 20.3 rn/sec.) Electrical (using SK-Photo or SK-PhotoR) Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC max. Alarm Current: 6.5 mA @ 24 VDC max (with LED on) M02-04-00 Test Magnet P48-21-00 Replacement End Cap for Metal Sampling Tube APA151 Remote annunciator with piezo alarm Important Notes: The use of either RTS15I or RTS1S1 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the SK-Duct installation instructions for more information The RTSI5I/RTSI5IKEY test coil circuit requires an external 24VDC power supply which must be UL listed. Accessory Current Loads at 24 VDC Device Standby Alarm RA100Z OmA 12mA Max. RTS151 OmA 12mA Max. RTS151KE7 12mA 12mA Max. Model SK-DUCT Air Duct Smoke Detector Engineering Specifications The air duct smoke detector shall be a SK-Duct photoelectric duct smoke detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4000 ft/mm (0.5 m/sec to 20.32 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTSI 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18AWG wiring. The unit housing shall be capable of mounting a relay module. Ordering Information SK-Duct Intelligent non-relay duct smoke detector SK-Photo Addressable Photo Detector SK-PhotoR Addressable Photo Detector with remote test capability (included with SK-Duct) SK-Relay Addressable Relay Module, must be added if relay function is required, (fits in housing) Accessoriest DST1 Metal Sampling Tube Duct Width up to 1' DST1 .5 Metal Sampling Tube Duct Widths V - 2' DST3 Metal Sampling Tube Duct Widths 2'- 4' DSTS Metal Sampling Tube Duct Widths 4'- 8' DST10 Metal Sampling Tube Duct Widths 8'— 12' DH4000E-1 Weatherproof Enclosure ETX Metal Exhaust Tube Duct width 1' RA100Z Remote LED Annunciator DCOIL Duct accessory coil, required if using with SK-Photo and not SK-PhotoR (included) with SK-Duct RTS151 Magnetic Remote Test station RTS1 51 KEY Key-Activated Remote Test station D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com MADE IN AMERICA FORM# 350122 Rev D © 2010 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 3242-0559:0162 PARENT LISTING No.: 3240-1653:0209 CATEGORY: 3240 - DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SILENT KNIGH/SE TY One Fire-Lite Place, Northford, CT,06472 Contact: Brant, 4846105 Email: lisa.brantwell.com DESIGN: Models SKDUCT* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: *Rev. 07-14-09 fm This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06/30/2025 Page 1 of 2 .•.., CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION i1rI OFFICE OF THE STATE FIRE MARSHAL 1119 FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: David Castillo , Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 D SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intellicient Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight lntelliknight series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA / SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following lntelliKnight FACP's: 5600 5700 5808 5820XL Model SK-Pull-DA and SK-Pull-SA Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 321 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Accessories BG-TR Optional trim ring. SB-I/O Surface backbox This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350135 Rev A 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, © 2009 Honeywell International Inc. by Honeywell Fax: (203) 484-7118. www.siIentknight.com __ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION i OFFICE OF THE STATE FIRE MARSHAL JI FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7150-0559:0161 PARENT LISTING No.: 7150-0028:0199 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY One Fire-Lite,P1ce, Northford, CT, 06472 Contact: Brant, Lisa 2034846105 Email: lisa.brant@honeywell.com __________________________________________ DESIGN: Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTES: 04-16-09 This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06/30/2025 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 S K-M in im on D SILENT KNIGHT by Honeywell > SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the lntelliKnight fire alarm control panels (FACP5). The SK-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features Single contact monitor SK-Minimon support for Class B (Style B) contact monitor wiring Small and lightweight size allows for flexible mounting options Rotary address switches for fast installation UL listed Specifications Electrical Standby Current: 400 uA max 24 VDC with comm. Voltage Range: 15 - 32 VDC End of Line Resistance: 47 k Ohms Physical Dimensions: 2.75" W x 1.3' H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Compatibility The SK-Minimon is compatible with the following lntelliKnight Systems: 5820XL 5808 5700 5600 (Rev 2.0 or higher) SK-FFT Approvals UL approved CSFM FM Approved SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The device shall be capable of Styles A and B supervised wiring to the load device. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Other Devices Wiring the SK-Minimon D SILENT This document is not intended to be used for installation purposes. We MADE IN AMERICA try to keep our product information up-to-date and accurate. We cannot KNIGHT cover all specific applications or anticipate all requirements. All FORM# 350133 Rev C specifications are subject to change without notice. For more information, by Honeywell contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2011 Honeywell International Inc Phone: (800) 328-0103, Fax: (203)484-7118. www.siIentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-0559:0155 PARENT LISTING No.: 7300-0028:0219 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa 2034846105 / Email: lisa.brant@honeywell.com/ DESIGN: Models IDP-Relay-6, , relay module, IDP-Control-6, SK -Control-6, /,IDP- supervising control m Monitor-10, SK-Mon-10, input monitor module, IDP- Zone-6, SK-Zone-6 si rface module, I DP-Monitor, IDP-Minimon, lDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK- Control, SK-Relay, control modules, lDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTES: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-25-11 mt Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to 1istees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 20f2 - SK-Relay Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the lntelliknight system, or to locate you nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161. Description The SK-Relay is an addressabe relay module for use with Silent Knight lntelliKnight series fire alarm control panels (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK-Relay is programmed with a unique sigialing line circuit (SLC) loop address. When an event occurs that controls the SK-Relay, the SK-Relay relay is triggered by the FACP.. Features Two sets of Form C contacts Installation The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box Rotary address switches for fast installation (System Sensor® PN SM13500) is available Contacts are rated for a variety of amps (see Specifications) from Silent Knight Panel controlled status LED that flashes green in normal state and is solid red in alarm Compatibility The SK-Relay is compatible with the following Relay programming is completely flexible—can be mapped to InteIIiKnight FACP's: zone conditions 5700 5808 Polling LED visible through the cover plate 5820XL Attractive ivory cover plate SEMS screws for easy wiring SILENT UL Listed KNIGHT 21 by Honeywell Model SK-Relay If Any Wiring to Terminals 3-9 Is Not Power Limited, the C8500 Barrier Is Required. The C13500 Includes a NonPowerLlmfted Label, Which Must Be Placed Over the Power Limited Terminal information on the Name Plate Label. To Next Device Ido0 Relay Common ij' 5• ° Normally Closed 2 I I Normally Open 2 ,•. 2 Relay Common I ' : Normally Closed lJa j' 4 0 _, _, - From Compatible FACP + or Previous Device Module Does Not Supervise ' Normally Open I Controlled Circuits 0 Wiring the 5K-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA (with LED latched on) Deoth: 1.1" SLC Loop Resistance: 40n max. Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15— 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 230 pA (LED flashing) direct pci1 255 pA (LED flashing) group poll Relay Contact Ratings 3.OA @ 30 VDC resistive 0.9A @ 110 VDC resistive 0.9A @ 125 VAC resistive 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350127 Rev © 2009 Honeywell International Inc. .j•,, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1I FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-0559:0155 PARENT LISTING No.: 7300-0028:0219 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY 93(e Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa 20348461,5 Email: lisa.brant@honeyweI,6om DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP- Zone-6, SK-Zone-6 six zone interlace module, IDP-Monitor, IDP-Minimon, IDP-Zone, 5K-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, I DP-Relay, SK- Control, 5K-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTES: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-25-11 mt Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N~r LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resuitsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06130/2025 Authorized By: David Castillo , Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 SK-PSG I SKmPS104--~ 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Silent Knight and is direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supplywith battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A(requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS Up to five (6 amp model) or seven (10 amp model) independently-configurable, power- limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power Optional addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Configurable for ANSl® Temporal 3or Temporal 4 coded output UL-Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet Ability to cascade up to four power supplies Two (6 amp model) or three (10 amp model) fully-isolated input/control circuits which can be programmed to any output Two Form C normally-closed trouble relays for AC Trouble and General Trouble 6 or 10 amp full load output, respectively, with 3 A maximum/circuit Individual NAC power and trouble LEDs for diagnostic efficiency Trouble history mode for diagnostic support Wide range end-of-line supervision value (normal: 2-27K ohms) Selectable earth fault detection (enable or disable) AC trouble report delay timer Completely configurable via onboard DIP switches, no extra software required Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring Includes integral battery charger capable of charging up to 33 AH batteries Cabinet can house two 7 Al-I or 18 AH batteries Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit ¶•I I 'd 4I(fl ORDERING INFORMATION SK-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six-circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two TAH or two 18AH batteries. Page 2 of 3 - SK-61095:C • 3/10/2021 SK-PS6 I SK-PS10 TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER SK-PS6: 120 VAC, 50/60 Hz, 5.04 maximum SK-PS10: 120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9- 16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS 24 VDC filtered SK-PS6: T138-TB9 - 1A Regulated, 34 special applications; TBIO-TB12 - 0.3A Regulated, 3A special applications SK-PSI0:T138-TB11 - 1.5A Regulated, 3A special applications; TBI2-TB14 - 0.3A Regulated, 3A special applications 6.0 A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs SECONDARY POWER (BATTERY) CHARGING CIRCUIT Supports lead-acid batteries only Float-charge voltage: 27.6 VDC Maximum current charge: 1.5 A Maximum battery capacity: 18 AH (inside cabinet) Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) Weight with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved HoneyweU Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com SK-61095 I c 1 03/21 @2021 Honeywell International Inc. Honeywell DSILENT' KNIGHT 11/5/24,12:44 PM LicenseBMLLINGCROSOSS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 1/2 11/5/24,12:44 PM LicenseBMLLINGCROSOSS This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listees data sheet, installation instructions and/or other suitable information sources. Listing Expires: 06/30/2025 Date Issued: 05/08/2024 Authorized By: Michael Huang , Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 212 System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. SYSTEM SENSOR® L.Series and L.Series with LED Indoor Selectable Horns, Strobes and Horn Strobes Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper-resistant construction Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use Agency Listings SIGNALING CI&US SIGNALING @ @ 0 LISTED LISTED LISTED APPROVED Horn Strobes and Strobes: S5512, S4011 Horns: S4011 Horns: 54011 3057072 FM23FPUS0195 730®1653:0525 7135-1653:0503 7135-1653:0526 The System Sensor L-Series and L-Series with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. AVDS916-01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG ULJULC Current Draw Data, Horn Tones, and Sound Output Data !JILIItsI1flTL117iIiTl7ThI '7 31 Leiviiimimum'Hoin Current Candela 16-33 Volts 8-17.5Volts 16-33Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 ---------- 75 70 70 95 75 75 110 85 - 115 - 90 135 105 - 150 - 110 177 - 115 185 120 - iemporai LOW 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 Cd) Sound Output (dBA) Switch Pos. Sound Pattern Volume Setting 15cd 30cd 75cd 95cd 16-33 Volts llOcd 115cd WALL CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd 16-33V WALL DC 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01 • 10/03/2023 • Page 2 6.83 diam. (173.5 mm) 6.92 4i3m (175. L-Series with LED Dimensions: Wall-Mounted Equipment I fl or SAV I ______ us. (39 cm) 58mm mm) L 58mm 32 mm I (91 cm) 5.27 1339 mm iss mm (13.7 cm) Q I isle A0617-00 A0547.00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) 2.OV I 47• 1.25 I— 4.82 118mm, t.25 195W 119mm (319 m ___________ (4.69 cm) - ___ ___ I op0110 t __ (1 CM) ON 5.6T 32 mm (1214 cmj 5.78 144 mm _________ I44m _____ A0613-00 A0549-00 A0554-01 Strobes, Horn Strobes Horn Surface Mount Back Box for Walls for Walls ( SBBRL/SBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDS9I6-01 • 10/03/2023 • Page 3 L-Series with LED: Ordering Information L-Series with LED Horn Strobes P2RLED 2-Wire, Horn Strobe, Wall, Red P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual P2GWLED 2-Wire, Compact Horn Strobe, Wall, White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO PC2RLED 2-Wire, Horn Strobe, Ceiling, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual PC2WLED 2-Wire, Horn Strobe, Ceiling, White PC2WLED-B 2-Wire,)I&n Strobe, Ceiling, White, Bilingual L-Series with LED Stj,øes SRLED ,4frobe, Wall, Red SRLED-B ,/ Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- ALERT Strobe, Wall, White, ALERT SWLED-ALERT Strobe, WajJ(hite, ALERT, Amber Lens SCRLED Strob?Ceiling, Red SCALED-B Ceiling, Red, Bilingual SCALED-P ,-Strobe, Ceiling, White, Plain SCWLEDk Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- Strobe, Ceiling, White, ALERT ALERT L-Series Horns HRL* Horn, Red HRLA* Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC Model Description LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-B3 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White TRC-2 Universal Ceiling Trim Ring, Red TRC-2W Universal Ceiling Trim Ring, White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Bezeist BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceilina White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. All -B models have "FIRE/FEW marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: *Hornonly models are listed for wall or ceiling use. Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). 3825 Ohio Avenue • St. Charles, IL 60174 USA System Sensor* isa registered trademark Phone: 800-SENSOR2 • Fax: 630-377-6495 at Honeywell international, Inc www.systemsensor.com SYSTEM Unity Drive, Mississauga, ON L5L 3S6 Canada t02523 system sensor. for current product Information, including the latest version of this data sheet. SENSOR' Phone. 800-SENSOA2 • Fax: 905-812-0771 subject to change without notice. tastsystemsenscccom www.systemsensor.ca AVD5916-01 • 1010312023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FI FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1653:0525 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporaild Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 / Contact: Brant, Lisa 203446105 Email: lisa.brant@hon.Swell.com /D-P. DESIGN: Models SRLED, SWLED, SRLED-B, SWLED-B, SRWLED-P, SRLED-SP, SWLED-SP, SWLED-CLR-ALERT, SCRLED, SCWLED, SCRLED-B, SCWLED-B, SCRLED-P, SCWLED-P, SCWLED-CLR-ALERT, SGRLED, SGWLED, SGRLED-B, SGWLED-B Ceiling or Wall Strobes. The 2-wire strobes come with 8 field selectable tone combinations and 7 field selectable candela settings. Models maybe mounted on the wall or ceiling as indicated and are intended for indoor dry/damp use only. Language designators: "-B" are bilingual (English/French). "-P" are plain versions (no wording). "-SP" are marked "FUEGO. Refer to listee's data sheet for additional detailed products description and operational considerations. RATING: 16-33 VDC Candela Ratings (cd): Wall Strobes: 15, 30, 75, 95, 110, 135, 185 Ceiling Strobes: 15, 30, 75, 95,115, 150, 177 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's Name, Model Number, Rating, and UL Label. APPROVAL: Listed as strobes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Model complies with the applicable requirements in UL 1638, 6th Edition and UL 1971, 3rd Edition. NOTES: 9-18-23 DAL Page 1 of 2 ...,. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/29/2024 Listing Expires: 06/3012025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (All SYSTEM $ SENSOR® L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper-resistant construction Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use Agency Listings SIGNAUIIG C&US SIGNALING @ @ 0 LISTED LISTED LISTED APPROVED Horn Strobes and Strobes: 05512, 54011 Horns: 54011 Horns: S4011 3057072 PM23FPUS0195 7300-1653:0525 7735-1653:0503 7135-1653:0526 The System Sensor L-Series and L.Serles with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. AVDS9I6-01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG ULILJLC Current Draw Data, Horn Tones, and Sound Output Data Candela Rating 16-33 Volts Wall Ceiling Candela 15 18 18 Range 30 22 22 75 70 70 95 75 75 110 85 - 115 - 90 135 105 - 150 - 110 177 - 115 185 120 - Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 Cd) Sound Output (dBA) Switch Pos. Sound Pattern Volume Setting 15cd 30cd 75cd 95cd 16-33 Volts 110cd 115cd WALL CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd 16-33V WALL DC 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01 • 10/03/2023 • Page 2 6.83w diam. (173.5 mm) 6.92w ,0am (175. L-Series with LED Dimensions: Wall-Mounted 2.07 -j tW 125 (9.1 cm) t25 4.4E-. I (53mm) 53mm 32 mm F ______ (3.9 cm) so MM (31.9 mm); up 1 00000 0 0000a 5.53. (13.7 cm) 5.27• 1 5.2r I339mmII V 33.9mm A0617-00 A0547-00 A0557.00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) A0613-00 Strobes, Horn Strobes Horn Surface Mount Back Box for Walls for Walls ( SBBRL/SBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment A0608-OO A0546-OO Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDS916-0 • 10/03/2023 • Page 3 L-Series with LED: Ordering Information lirII L-Series with LED Horn S)irces P2RLED 2)Wit' Horn Strobe, Wall, Red P2RLED-B -'2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED k( 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual P2GWLED 2-Wire, Compact Horn Strobe, Wall, White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, Bilingual P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO P2WLED-SP 2-Wire, H9nrobe, Wall, White, FUEGO PC21RLED 2-Wjeiorn Strobe, Ceiling, Red PC2RLED-B -'Wire, Horn Strobe, Ceiling, Red, Bilingual PC2WLED 2-Wire, Horn Strobe, Ceiling, White PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual L-Series with LED Strobes SRLED Strobe, Wall, Red SRLED-B Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- ALERT Strobe, Wall, White, ALERT SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red SCRLED-B Strobe, Ceiling, Red, Bilingual SCALED-P Strobe, Ceiling, White, Plain SCWLED Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- ALERT Strobe, Ceiling, White, ALERT L-Series Horns HRL* Horn, Red HRLA° Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL° Compact Horn, Red HGRLA° Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-83 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White TRC-2 Universal Ceiling Trim Ring, Red TRC-2W Universal Ceiling Trim Ring, White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Bezelst BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. All -B models have "FIRE/FEU" marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: "Horn-only models are listed for wall or ceiling use. Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). SYSTEM SENSOR° 3825 Ohio Avenue • St. Charles, IL 60174 USA Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada Phone: 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca System Sensor is registered trademark of Honeywell International, Inc 02023 System Sensor. Product specifications subject to change without notice. ti'oit oystemuensor.000r for current product information, Including the latest verona of this data sheet, AVDS916-01 • 10103/2023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7135-1653:0526 CATEGORY: 7135 - AUDIBLE DEVICES LISTEE: System Sensor, Unincorporaéd Div of Honeywll Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 / Contact: Brant, Lisa 203446105 Email: lisa.brant@honee4ell.com DESIGN: - - - Models P2RLED P2WLED P2RLE B, P2WLED B P2RLED P, P2WLED P, P2RLED SP, P2WLED-SP, PC2RLED, PC2WLED, PC2RLED-B, PC2WLED-B, P2GRLED, P2GWLED, P2GRLED-B, P2GWLED-B Ceiling or Wall Horn Strobes. The horn strobes come with 8 field selectable tone combinations and 7 field selectable candela settings. Models maybe mounted on the wall or ceiling as indicated and are intended for indoor dry/damp use only. Language designators: "-B" are bilingual (English/French). "-P" are plain versions (no wording). "-SP" are marked "FUEGO". Refer to listee's data sheet for additional detailed products description and operational considerations. RATING: 16-33 VDC Candela Ratings (Cd): Wall Horn Strobes: 15, 30, 75, 95, 110, 135, 185 Ceiling Horn Strobes: 15, 30, 75, 95, 115, 150, 177 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's Name, Model Number, Rating, and UL Label. Page 1 of 2 ..... CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION iTI OFFICE OF THE STATE FIRE MARSHAL 1JA9 FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Model complies with the applicable requirements in UL 464, 11th Edition, UL 1638, 6th Edition, and UL 1971, 3rd Edition. 9-18-23 DAL This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational i" requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 (E)POTTER The Symbol of Protection Features NEMA 4X* (IP 65) and 6P (IP 67) *Enclosure is 4X For additional corrosion protection of mounting hardware, use model OSYSU-2 CRH -40° to 1400 (-40°C to 60°C) operating temperature range Visual switch indicators Two conduit entrances Adjustable length trip rod Accomodates up to 12AWG wire Three position switch detects tampering and valve closure Knurled mounting bracket prevents slipping Fine adjustment feature for fast, easy installation RoHS compliant One or two SPDT contact models (-1,-2) Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. OSYSU Series Outside Screw and Yoke Vqlv Supervisory Switch SgG L I I L LISTED APPROVED Important: This document contains important information on the installation and operation of OS&Y valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS&Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as '/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device. Testing The operation of the OSYSU and its associated protective monitoring system shall be inspected, tested, and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Jurisdiction (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve wheel towards the closed position. The OSYSU shall operate within the first two revolutions of the wheel. Fully close the valve and ensure that the OSYSU does not restore. Fully open the valve and ensure that the OSYSU restores to normal only when the valve is fully opened. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Technical Specifications Dimensions See Fig 8 Weight 1.6 lbs (0,73 kg) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Tamper Resistant Screws Cover Tamper Optional Cover Tamper Switch Available OSYSU-1: One Set of SPDT (Form C) OSYSU-2: Two Sets of SPDT (Form C) Contact Ratings 10.0 Amps at 125/250 VAC 2.0 Amps at 30VDC Resistive 10 mAmps minimum at 24 VDC -40° F to 140°F (-40°C to 60°C) Environmental NEMA 4X (IP 65) and NEMA 6P (IP 67) Enclosure Limitations (Use suitably rated conduit and connector) Indoor or Outdoor Use (See OSYSU-EX Bulletin 5400705 for Hazardous locations) Conduit Two Knockouts for 1/2" conduit provided Entrances (See Notice on Page 6 and Fig. 9 on Page 5) Service Use NFPA 13,13D, 13R, 72 Specifications subject to change without notice Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 540i525- REV G • 6/19 PAGE IOF6 OSYSU Series @POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Theory of Operation The OSYSU is a 3 position switch. The center position is the normal installation position. Normal is when the switch is installed on the OS&Y valve, the valve is fully open and the trip rod of the OSYSU is in the groove of the valve stem. Closing the valve causes the trip rod to ride up out of the groove and activates the switches. Removing the OSYSU from the valve causes the spring to pull the trip rod in the other direction and activates the switches. Visual Switch Status Indication There are 3 visual indicators to determine the status of the switches. Fig I; the actuator button of the micro switches are on the raised section of the switch actuator. Fig 2; the trip rod is perpendicular to the base and lined up with the alignment mark on the mounting bracket. Fig 3; the white visual indicator is visible through the window on the back of the switch actuator. A final test is to meter the contacts marked COM and N.O. to ensure they are an open circuit when the valve is open and that they close and have continuity within 2 revolutions of turning the valve handwheel towards the closed position and the contacts remain closed as the valve is completely closed and until the valve is completely opened when the trip rod drops back into the groove in the valve stem. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525 - REV G • 6/19 PAGE 2 0F6 OSYSU Series () POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Small Valve Installation - 1/2" Through 2 1/2" Sizes Fig uu CILii Slotted mounting holes and micro-adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Small Valve Installation NOTE: If the valve stem is pre-grooved at 1/8" minimum depth; proceed to step 7. Remove and discard "E' ring and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 6 if possible to avoid creating a pinch point between the wheel and the OSYSU. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 10). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. Utilizing a 3/16" or 1/4" diameter straight file, file a 1/8" minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16" can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 6, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2 , to aid in initially locating the OSYSU. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. Tighten the adjustment screws and all mounting hardware securely (20 in-lbs minimum). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. JO. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV G • 6/19 PAGE 3OF6 (E)POTTER The Symbol of Protection OSYSU Series Outside Screw and Yoke Vqlv Supervisory Switch = Slotted mounting holes and micro- adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Large Valve Installation NOTE: If the valve stem is pre-grooved at 1/8" minimum depth; proceed to step 6. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far from the valve gland as possible so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 7 if possible to avoid creating a pinch point between the wheel and the OSYSU. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw,but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 10). Reinstall trip rod and repeat Step 3 procedure. Mark the valve stem at the center of the trip rod. Remove the OSYSU. Utilizing a 3/8" or Y2" diameter straight file, file a 1/8" minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16" can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 7, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2 , to aid in initially locating the OSYSU. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. Tighten the adjustment screws and mounting hardware securely (minimum 20 in-lbs). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in ala/se valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV G • 6/19 PAGE 4OF6 Rod retracted and 1.17 breakaway section removed Cover Tamper Switch 305 [77.47 2.25 57.13 (E)POTTER The Symbol of Protection OSYSU Series Outside Screw and Yoke Vqlv Supervisory Switch Dimensions Fig 8 I (2)o.886 Knockouts For I Electrical Condu Connections Ground l/4"-20 Hardw Clamp Ba Knockout Removal Fig 9 To remove knockouts: Place screwdriver at inside edge of knockouts, not in ved the center. NOTE: Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV G • 6/19 PAGE 5OF6 OSYSU Series () POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Breaking Excessive Rod Length Fig 10 Switch Terminal Connections Clamping Plate Terminal Fig 11 WARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8' of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. All conduit and connectors selected for the installation of this product shall be suitable for the environment for which it is to be used and shall be installed to the manufacturer's installation instructions. For NEMA 4, 4X, 6, 6P installations, the cover screws are recommended to be tightened to 15 in- lbs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 12 EOLR CMNC N NONCCOM ,I..I—I..I—I—I—I TO FIRE ALARM PANEL Ordering Information Model Description Stock No. OSYSU-1 Outside Screw & Yoke 1010102 Supervisory Switch (Single switch) OSYSU-2 Outside Screw & Yoke 1010202 Supervisory Switch (Double switch) OSYSU-2 Outside Screw & Yoke Supervisory 1010210 CRH Switch (Double Switch). Corrosion resistant hardware of 316 stainless steel Cover Screw 5490424 Hex Key for Cover Screws and 5250062 Installation Adjustments Optional Cover Tamper Switch Kit 0090200 Engineering Specifications: OS&Y Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches shall be furnished and installed on all OS&Y type valves that can be used to shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure.. The enclosure shall be held captive by tamper resistant screws. The device shall contain two V2" conduit entrances and one or two Single Pole Double Throw (SPDT) switches. There shall be a visual indicator to display the status of the switches. To aid in installation, it shall be possible to make fine adjustments to the position of the switch on the valve without loosening the mounting bracket from the valve. The device shall contain an adjustable length trip rod and roller, the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at bA, 125/250VAC and 2A, 30VDC. OS&Y Valve supervisory switch shall be model OSYSU-1 for the single switch model and OSYSU-2 for the two switch model manufactured by Potter Electric Signal Company LLC Supervisory switches have a normal service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 150 9001:2015 1 DESIGNING, MANUFACTURING, M ' &DISTRIBUTING QUALITY SYSTEMS 5401525-REV G • 6/19 PAGE 6 OF 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM Nzr LISTING SERVICE LISTING No.: 7770-0328:0010 CATEGORY: 7770 - VALVES/SWITCHES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO, 63042 Contact: Lakomiak, Neil 314-816-8679 Email: neillpottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W WLS-S PS-40A Zz PS-120A OSYSU-2 OSYS-B PMS PTS-B 0SYSU-1 GVS PC VS-i PIVS-B ITS-S TTS-W PCVS- 2 WLS PTS-C PS40 PSI20 RBVS *PSI5 *PS25 RATING: INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTES: Formerly 7738-0328:010 *Revision 09-07- 2016 dc Page 1 of 2 ..,, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ri OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/02/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 DIMENSIONS mm(inch) 'A~' v F1 F2 (FAB1ON TAB NO. 187) (FABTON TAB NO. 5A) 65±I(2.561.O4) 151±1(5.9410.04) r i L MOM l - B8O .II!Wu. Pb E $ 7- 12 SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate ( 0.36A to 10.50V) 7.2Ah 10 hour rate ( 0.72A to 10.50V) 6.84Ah 5 hour rate (1 .22A to 10.20V) 6.12Ah 1 C (7.2A to 9.60V) 3.24Ah 3C (21.6A to 9.60V) 2.52Ah Weight Approx. 5.39Lbs. (2.45kg) Internal Resistance (at 1KHz) 22 mQ Maximum Discharge Current for 30 seconds: 144A Maximum Discharge Current for 5 seconds : 288A Operating Temperature Range Charge 0°C (32°F ) to 40°C (104°F) Discharge -15°C ( 5°F ) to 50°C (122°F) Storage -15°C ( 5°F ) to 40°C (104°F) Charge Retention (shelf life) at 20°C ( 68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use : Charging Voltage 14.4 to 15.OV Maximum Charging Current : 2.16A Standby Use: Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use : 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use : 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) Terminal Fl or F2 Maintenance-Free Rechargeable Sealed Lead-Acid Battery MK Battery 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com Nominal Voltage (V) 12V Nominal Capacity 20 hour rate ( 0.9A to 10.50V) 18Ah 10 hour rate ( 1.8A to 10.50V) 17.1Ah 5 hour rate (3.06A to 10.20V) 15.3Ah 1C (18Ato9.60V) 8.1Ah 3C (54A to 9.60V) 6.3Ah Weight Approx. 13.82Lbs. (6.28kg) Internal Resistance (at 1KHz) 10 mQ Maximum Discharge Current for 30 seconds: 360A 7 V a ($1712 SPECIFICATIONS Maintenance-Free Rechargeable Sealed Lead-Acid Battery Maximum Discharge Current for 5 seconds: 720A Operating Temperature Range Charge 0°C (32°F ) to 40°C (104°F) Discharge -15°C ( 5°F ) to 50°C (122°F) Storage -15°C (5°F) to 40°C (104°F) Charge Retention (shelf life) at 20°C (68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use : Charging Voltage 14.4 to 15.OV Maximum Charging Current : 5.4A Standby Use : Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use : 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use : 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) Terminal F2orF3 DIMENSIONS mm(inch) 12 FEW F3 (FASTON TAB NO. 25) (MS Bolts) el A 181±(7.13±( 76±(2.99* - CE Pb 5511-12 Vii 41 ..._4tlT43J 12V.1525121311 MK Battery 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com V 144LW- i:: t i I I Invoice #1897 InvOice DATE 11/06/2024 INVOICE# 1897 TERMS Cash On Delivery 11/6/24, 1:59 PM (JJJ~k Standard o:cs 613 W Main St El Cajon, CA 92020 (619) 596-9950 service@standardelectronics.us BILL TO SERVICE LOCATION GROSSMONT HIGH SCH. DIST. MT. MIGUEL HIGH SCHOOL 1100 Murray Dr 8585 Blossom Ln El Cajon California 92020-5664 Spring Valley California 91977-3765 (619) 644-8000 (619) 318-7480 JOB# DATE PO/REF# DESCRIPTION 1014275219 11/06/2024 Please make sure MSF has admin rights to computer Keith to install remote link and grant access for Alison Ford Tech Notes: Programmed remote link. Showed MSF how to program system. Job Charges Qty Rate Total * SERV LABOR 2.00 $120.00 $240.00 * Fuel Sur Charge 1.00 $20.00 $20.00 Job Subtotal $260.00 Job Total $260.00 PRE-WORK SIGNATURE POST-WORK SIGNATURE Signed B . F Signed By: [ 1 CUSTOMER MESSAGE Invoice Total: $260.00 Deposits (-): $0.00 Payments (-): $0.00 Total Due: $260.00 https://admin.servicefusion.com/accounting/printlnvoice?id=eRsaMmi25vKnAN-3AVZbsg1 hi 97EPFC5247g449FXBY ill