Loading...
HomeMy WebLinkAbout3259 LINCOLN ST; ; FPR2023-0084; PermitPERMIT C city of fl REPORT Carlsbad I Print Date: 02/19/2025 Job Address: 3259 LINCOLN ST, CARLSBAD, CA 92008-3131 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2041311500 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2023-0084 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 12/19/2023 Issued: 02/15/2024 Finaled Close Out: 02/19/2025 Final Inspection: INSPECTOR: Cheung, Nathaniel Robinson, Jarrod Project Title: Description: BLAUVELT RESIDENCE -INSTALLATION OF NEW 13D SPRINKLER SYSTEM FOR NEW SFR & ATTACHED ADU (40 HEADS) FPContractor: RIOS FIRE PROTECTION INC P0 BOX 1546 EL CAJON, CA 92022-1546 (619) 212-0956 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $157.00 FIRE NFPA 13D Single Family System (Plan Review) $310.00 Total Fees: $467.00 Total Payments To Date: $467.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov M&TI (0J'I liltI 31 go ON, January 16, 2024 HYDRAULIC CALCULATIONS FOR BEAU VELT RESIDENCE FILE NUMBER: 01-332 OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: 05 gpm/256 sq.ft. AREA OF APPLICATION: LIVING COVERAGE OF SPRINKLER: 16'X 16" NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.2 gpm TOTAL WATER REQUIRED (including hose): 31.2 gpm FLOW AND PRESSURE (@ BOR): 26.2 gpm @ 27.4 psi SPRINKLER ORIFICE SIZE: W inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION INC. DESIGNER: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT, CONTRACTOR CERTIFICATION NUMBER: Cl 6-1025305 WATER DEPARTMENT: CARLSBAD WATER 01ST. CONTACT: MARKUS MOKLER DATE: 12/7/23 STATIC: 85 psi BBB. 1l1 P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com 2 G B 60.0 100.0 E:IeRo] G A P R E S S U R E 20.0 p 5 i -14.7 40.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE 1/14/2024 C:;\USERS\CANDI\ONEDRIVE\DESKTOP\BLAUVELT RES.SDF JOB TITLE: BLAUVELT RES WATER SUPPLY ANALYSIS Static: 76.00 psi Resid: 75.00 psi Flow: 500.0 gpm LEGEND 1 jAvailable pressure 75.99 psi @ 31.2 gpm 2 qRequired pressure 66..42 psi @ 31.2 gpm Source Supply Curve System Demand Curve 100150 200 250 300 350 400 450 500 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE 1/14/2024 C:\USERS\CANDI\ONEDRIVE\DESKTOF\BLAUVELT RES..SDF JOB TITLE:. BLAUVELT RES NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 76.0 75.0 500.0 76.0 31..2 66.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5..0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 14 25.0 K= 4.90 7.0 13.0 13 25.0 K= 4.90 7..2 13.2 12 25.0 - - - - 7.7 - - - 11 25.0 - - - - 10..4 - - - 10 25.0 - - - - 12..1 - - - 9 25.0 - - - - 12.7 - - - 8 15.0 - - - - 16.9 - - - 7 15.0 - - - - 17.9 - - - 6 15.0 - - - - 23.2 - - - 5 9.0 HOSE STREAM 27.4 5.0 4 5.0 - - - - 30.6 - - - 3 3.0 - - - - 34.8 - - - 2 3.0 - - - - 60.8 - - - SOURCE 0.0 SOURCE 66.4 31..2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE:: 1/14/2024 C::\USERS\CANDI\ONEDRIVE\DESKTOP\BLAUVELT RES..SDF JOB TITLE:: BLAUVELT RES NFPA PIPE DATA 5 Pipe Tag K-fac Add Fl Add Fl To Fit:: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft..) T Pf/ft. (Pf) Pipe:. 1 Source 0.0 7.0 10.00 150 5.6 SOURCE 0.0 66..4 31..2 3 1.000 7.00 1.3 2 3..0 60.8 31.2 0.995 17.00 0.254 4.3 Pipe: 2 0..0 Fixed Pressure Loss Device 2 3..0 60.8 31.2 4 26.0 psi, 31..1 gpm 3 3.0 34.8 31..1 Pipe:. 3 0.0 0.0 3.0 65.00 150 4.2 3 3.0 34.8 31.2 5 1.250 3.00 0..9 4 5.0 30.6 31.2 1.394 68.00 0.049 3.3 Pipe: 4 H.S. 5.0 Disch 3.0 5.00 150 3.3 4 5..0 30.6 26.2 6 1.000 3.00 1.7 5 9.0 27.4 31.2 1.055 8.00 0.190 1.5 Pipe: 5 0.0 0.0 8.0 6.00 150 4.2 5 9.0 27.4 26.2 7 1.000 8.00 2..6 6 15.0 23.2 26.2 1.101 14.00 0.112 1.6 Pipe: 6 0.0 8.1 9 25..0 22.00 150 5.3 6 15.0 23.2 18.0 8 1.000 25.00 -0.0 7 15.0 17.9 26.2 1.101 47.00 0.112 5.3 Pipe:. 7 0.0 7.4 10 10.0 8.00 150 1.0 7 15.0 17.9 10.6 11 1.000 10.00 -0.0 8 15.0 16.9 18.0 1.101 18.00 0.056 1.0 Pipe: 8 0.0 0.0 36.0 36.00 150 5.3 7 15.0 17.9 8.1 10 1.000 36.00 4.3 9 25.0 12.7 8.1 1.101 72.00 0.013 0.9 Pipe: 9 0.0 26..2 12 47.0 59.00 150 6.6 8 15.0 16.9 -15.5 1.000 47.00 4.3 11 25.0 10.4 10.6 1.101 106.00 0.021 2.2 Pipe: 10 0.0 15.5 11 26.0 19.00 150 4.8 8 15.0 16.9 -8.1 1.000 26.00 4.3 10 25.0 12.1 7.4 1.101 45.00 0.011 0.5 Pipe: 11 0.0 15.5 11 19.0 25.00 150 0.6 9 25.0 12.7 -7.4 1.000 19.00 -0.0 10 25.0 12.1 8.1 1.101 44.00 0.013 0.6 Pipe: 12 0.0 26.2 12 16.0 25.00 150 1.7 10 25.0 12.1 -10.6 1.000 16.00 -0.0 11 25.0 10.4 15.5 1.101 41.00 0.043 1.7 Pipe: 13 0.0 13.0 14 10.0 14.00 150 2.7 11 25.0 10.4 13.2 13 1.000 10.00 -0.0 12 25.0 7.7 26.2 1.101 24.00 0.112 2.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE 1.114/2024 C::\USERS\CANDI\ONEDRIVE\DESKTOP\BLAUvELT RES..SDF JOB TITLE:: BLAUVELT RES Pipe Tag K-fac Add Fl Add Fl To Fit:: L C Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F To Node El (ft) PT Tot..(Q) Disch Act ID (ft.) T Pf/ft., Pipe:: 14 4.90 13.2 Disch 12.0 3.00 150 12 25.0 7.7 0.0 1.000 12.00 13 25.0 7.2 13..2 1.101 15.00 0.031 Pipe: 15 4.90 13.0 Disch 10.0 11.00 150 12 25..0 7..7 0..0 1.000 10.00 14 25..0 7..0 13..0 1.101 21.00 0.031 NOTES (HASS) Calculations were performed by the HASS 2023 D computer program in accordance with NFPA (2020) under license no.. 64916306 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.014 gpm and a maximum imbalance at any node of 0.182 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 75.99 psi with a flow of 35.57 gpm. PIPE FITTINGS TABLE User Pipe Table Name: CPVC PAGE: A MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C L B D N E45 TEE TRUN COUPLN L90 BRANCH -------------------------------------------------------- G F 1.101 1.00 5.00 1.00 2.00 7.00 4.00 0.00 0.00 0.00 0.00 (Pt) (Pe) (Pf) 0.5 -0.0 0.5 0.6 -0.. 0 0.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE:: 1/14/2024 C:'\USERS\CANDI\ONEDRIVE\DESKTOP\BLAtJVELT RES..SDF JOB TITLE:: BLAUVELT RES PAGE:: * MATERIAL:' Custom Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv ---------------------------------------------------------- BfyVlv GatVlv AlmChk DPVlv NPTee F45E11 0.995 1.55 3.87 1.55 3.87 4.64 0.77 7.73 1.55 3.87 0.77 1.055 2.06 5.14 2.06 5.14 6.17 1.03 10.28 2.06 5.14 1.03 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 1.58 RIOS FIRE PROTECTION, INC. January 16, 2024 HYDRAULIC CALCULATIONS FOR BLAUVELT RESIDENCE FILE NUMBER: 01-332 OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/400 sq.ft. AREA OF APPLICATION: LIVING COVERAGE OF SPRINKLER: 20'X 20" NUMBER OF SPRINKLERS: 1 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 20.0 gpm TOTAL WATER REQUIRED (including hose): 25.0 gpm FLOW AND PRESSURE (@ BOR): 20.0 gpm @ 32.8 psi SPRINKLER ORIFICE SIZE: ½" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION INC. DESIGNER: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD WATER DIST. CONTACT: MARKUS MOHLER DATE: 12/7/23 STATIC: 85 psi BBB. P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page :2 DATE:: 1.114/2024 C:\USERS\CANDI\ONEDRIVE\DESKTOP\BLAUVELT RES.SDF JOB TITLE:: BLAUVELT RES WATER SUPPLY ANALYSIS Static: 76.00 psi Resid: 75.00 psi Flow: 500.0 gpm 100.0 G 1 A U 2 G E 60.0 P R E S 40.0 S U R B 20.0 p S ± -14.7 LEGEND 1 gAvailable pressure 76.00 psi @ 25..0 gpm 2 qRequired pressure 68.77 psi @ 25.0 gpm A.. Source Supply Curve B. System Demand Curve 100150 200 250 300 350 400 450 500 FLOW (GEM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC, ANALYSIS Page 3 DATE: 1V14/2024 C:\USERS\CANDI\ONEDRIVE\DESKTOP\ELAUVELT RES..SDF JOE TITLE:. BLAUVELT RES NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL.. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS.. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 76.0 75.0 500..0 76..0 25.0 68.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 25..0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE. STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 14 25.0 K= 4.90 16.7 20.0 13 25.0 - - - - 18.1 - - - 12 25.0 - - - - 18.1 - - - 11 25.0 - - - - 19.7 - - - 10 25..0 - - - - 20.8 - - - 9 25.0 - - - - 21.1 - - - 8 15.0 - - - - 25.4 - - - 7 15.0 - - - - 26..0 - - - 6 15.0 - - - - 29.2 - - - 5 9.0 HOSE STREAM 32.8 5.0 4 5.0 - - - - 35.5 - - - 3 3.0 - - - - 38..6 - - - 2 3.0 - - - - 64.6 - - - SOURCE 0.0 SOURCE 68.8 25.0 SPRINKLER SYSTEM HYDRAULIC. ANALYSIS Page 4 DATE:; 1/14/2024 C::\USERS\CANDI\ONEDRIVE\DESKTOP\BLArjvELT RES.SDF JOB TITLE:; BLAUVELT RES . * NFPA PIPE DATA 5 Pipe Tag K-fac Add Fl Add FL To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot..(Q) Disch Act ID (ft..) T Pf/ft.. (Pf) Pipe: 1 Source 0.0 7.0 10.00 150 4.2 SOURCE 0.0 68..8 25.0 3 1.000 7.00 1.3 2 3..0 64.6 25.0 0.995 17.00 0.168 2..9 Pipe: 2 0.0 Fixed Pressure Loss Device 2 3.0 64.6 25.0 4 26.0 psi, 25..0 gpm 3 3.0 38.6 25.0 Pipe: 3 0.0 0.0 3.0 65.00 150 3.1 3 3.0 38.6 25.0 5 1.250 3.00 0.9 4 5.0 35..5 25.0 1.394 68.00 0.033 2.2 Pipe: 4 H.S. 5.0 Disch 3.0 5.00 150 2.7 4 5.0 35.5 20.0 6 1.000 3.00 1.7 5 9.0 32.8 25.0 1.055 8.00 0.127 1.0 Pipe: 5 0.0 0.0 8.0 6.00 150 3.6 5 9.0 32.8 20.0 7 1.000 8.00 2.6 6 15..0 29.2 20.0 1.101 14.00 0.068 1.0 Pipe: 6 0.0 6.2 9 25.0 22.00 150 3.2 6 15.0 29..2 13.8 8 1.000 25.00 -0..0 7 15.0 26.0 20.0 1.101 47.00 0.068 3.2 Pipe: 7 0.0 5.7 10 10.0 8.00 150 0.6 7 15.0 26.0 8.1 11 1.000 10.00 -0.0 8 15.0 25.4 13.8 1.101 18.00 0.034 0.6 Pipe: 8 0.0 0.0 36.0 36.00 150 4.9 7 15.0 26.0 6.2 10 1.000 36.00 4.3 9 25.0 21.1 6.2 1.101 72.00 0.008 0.6 Pipe:. 9 0.0 20.0 12 47.0 59.00 150 5.7 8 15.0 25.4 -11.9 1.000 47.00 4.3 11 25.0 19.7 8.1 1.101 106.00 0.013 1.4 Pipe: 10 0.0 11.9 11 26.0 19.00 150 4.6 8 15.0 25.4 -6.2 1.000 26.00 4.3 10 25.0 20.8 5.7 1.101 45.00 0.007 0.3 Pipe: 11 0.0 11.9 11 19.0 25.00 150 0.3 9 25.0 21.1 -5.7 1.000 19.00 -0.0 10 25.0 20.8 6.2 1.101 44.00 0.008 0.3 Pipe: 12 0.0 20.0 12 16.0 25.00 150 1.1 10 25.0 20.8 -8.1 1.000 16.00 -0.0 11 25.0 19.7 11.9 1.101 41.00 0.026 1.1 Pipe: 13 0.0 0.0 10.0 14.00 150 1.6 11 25.0 19.7 20.0 14 1.000 10.00 -0.0 12 25.0 18.1 20.0 1.101 24.00 0.068 1.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE:. 1Y14•/2024 C:\USERS\CANDI\ONEDRIVE\DESKTOP\BLAUVELT RES..SDF JOB TITLE: BLAUVELT RES Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq..Ln.. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft..) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 12..0 3.00 150 0.0 13 25.0 18.1 0..0 1.000 12.00 -0.0 12 250 18.1 0.0 1.101 15.00 0.000 0.0 Pipe: 15 4.90 20.0 Disch 10.0 11.00 150 1..4 12 25.0 18.1 0.0 1.000 10.00 -0.0 14 25.0 16.7 20..0 1.101 21.00 0.068 1..4 NOTES (HASS) :: Calculations were performed by the HASS 2023 D computer program in accordance with NFPA (2020) under license no. 64916306 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.008 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.3 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 76.00 psi with a flow of 27.32 gpm. PIPE FITTINGS TABLE User Pipe Table Name: CPVC PAGE: A MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C L B D N E45 TEE TRUN COUPLN L90 BRANCH -------------------------------------------------------- G F 1.10: 1.00 5.00 1.00 2.00 7.00 4.00 0.00 0.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 1/14/2024 C:\USERS\CANDI\ONEDRIVE\DESKTOP\BLUvELT RES..SDF JOB TITLE:. BLAUVELT RES PAGE: * MATERIAL: Custom Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AimChk DPVlv NPTee F F45E11 0.995 1.55 3.87 1.55 3.87 4.64 0.77 7.73 1.55 3.87 0.77 1.055 2.06 5.14 2.06 5.14 6.17 1.03 10.28 2.06 5.14 1.03 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 1.58 Worldwide t-qcaa Contacts www.tyco-fire.com Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe System IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp446 General Description The TYCO Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY2534) are decorative, glass bulb sprinklers, available in both ordinary 155°F (68°C) and intermediate 200°F (93°C) temperature rated configura- tions. They are designed for use in res- idential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers provides 3/4" (19,1 mm) vertical adjustment. This adjust- ment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: Wet pipe residential sprinkler sys- tems for one and two family dwell- ings and mobile homes per NFPA 13D Wet pipe residential sprinkler sys- tems for residential occupancies up to and including four stories in height per NFPA 13R Wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY2534) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. The Series LFII Residential Concealed Pendent Sprinklers (TY2534) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY2534 Technical Data Approvals UL and C-UL Listed Australian WaterMark Certified The TYCO Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII Concealed Cover Plates having factory-applied finishes. Sprinklers and Cover Plates are separately ordered. See the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Page 1 of 4 AUGUST 2022 TFP446 SUPPOR CUP WIT ROLL FOR THREAD SEALIN( ASSEMBI GUIDE PIN BRIDGE FRAME 1/2 NPT) RINKLER tJRENCH FLATS BUTTON BULB APRESSION SCREW DEFLECTOR I I I I I I I DEFLECTOR I I I I II II (OPERATED I I POSITION) II I I ii I THREAD INTO SPRINKLER ASSEMBLY RETAINER SUPPORT WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS FLUSH WITH CEILING EJECTION SPRING SOLDER TAB —" COVER PLATE ASSEMBLY '- COVER PLATE FIGURE 1 SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY2534) TFP446 Page 2 of 4 WET PIPE SYSTEM Maximum Maximum Minimum Flow and Residual Pressure 2,3 Coverage 1 Area Spacing Temperature ft Rating Flow Pressure Minimum ft x ft (m) GPM PS Installation Spacing (m x m) (LPM) (bar) to Ceiling g Type ft (m) 12x12 (3,7x3,7) 12 (3,7) 13 (49,2) 7.0 (0,48) Smooth Ceilings 318to1 1/8 in. 14x14 14 13 7.0 (4,3 X 4,3) (4,3) 155°F (68°C), (49,2) (0,48) Beamed Ceilings per NFPA 13Dor Concealed 8 16x16 16 13 7.0 (4,9 x 4,9) (4,9) 200°F (93°C) (49,2) (0,48) 13R, or 13. Installed in beam (2,4) 18 x 18 18 17 12.0 (5,5 x 5,5) (5,5) (64,3) (0,83) 3/8 to 1 1/8 in. below bottom of 20 x 20 20 20 16.7 Al x 6,1 (6,1) (75,7) beam) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 GPM/ft° over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY2534) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Discharge Coefficient K=4.9 GPM/psi½ (70,6 LPM/bar) Temperature Rating Ordinary 155°F (68°C) Sprinkler 139°F (59°C) Cover Plate Note: Maximum Ambient Ceiling Tempera- ture for the ordinary temperature configura- tion is 100°F (38°C). Intermediate 200°F (93°C) Sprinkler 165°F (74°C) Cover Plate Note: Maximum Ambient Ceiling Tempera- ture for the intermediate temperature con- figuration is 150°F (65°C). Vertical Adjustment 3/4 in. (19,1 mm) Finishes See the Ordering Procedure section Physical Characteristics Frame .............................Brass Support Cup ...................Plated Steel Guide Pins .................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb...............................Glass Button ...................Phosphor Bronze Sealing Assembly. . Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer ......................Plated Steel Cover Plate Election Spring . . . . Stainless Steel Bridge ............................Bronze Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector, supported by the Guide Pins, then drops down to its operated position. TFP446 Page 3 of 4 2-1/2" DIA. 3/4" (19,1 mm) FACE OF SPRINKLER- (63,5 mm) THREADED SPRINKLER SUPPORT CUP ADJUSTMENT FITTING ASSEMBLY SPRINKLER 3/32 GAP 21'318' I (54,0 mm COVER PLATE ±9,5 mm) RETAINER (2,4 mm) OPERATED 9/16 (14,3 mm) COVER- SPRINKLER- 5/32 j MOUNTING REPLACE AFTER INSTALLATION RETAINER SUPPORT CUP I ASSEMBLY ASSEMBLY (4,0 mm) SURFACE / 1-5/16' (33,3 mm) 3-1/4" DIA._______ DISPOSABLE DEFLECTOR IN (82,6 mm) PP PROTECTIVE CAP TIP OPERATED POSITION FIGURE 2 SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY2534) INSTALLATION DIMENSIONS, PROTECTIVE CAP, AND ACTIVATED DEFLECTOR The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Design Criteria The TYCO Series LFII Residential Con- cealed Pendent Sprinklers (TY2534) are UL and 0-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area A minimum discharge of 0.1 GPM/ft2 over the design area comprised of the four most hydraulically demand- ing sprinklers for actual coverage areas protected by the four sprinklers Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (see Table A) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The TYCO Series LFII Residential Con- cealed Pendent Sprinklers (TY2534) must be installed in accordance with this section. WRENCH RECESS OE1/2' SQUARE U DRIVE SOCKET FIGURE 3 W-TYPE 42 SPRINKLER WRENCH General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb, With the sprin- kler held horizontally, a small air bubble should be present. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under-or over- tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads and using the W-Type 42 Wrench shown in Figure 3, position the wrench recess to first straddle the deflector guide pins from the side and then push the wrench into TFP446 Page 4 of 4 the support cup to engage the sprin- kler wrench flats. Rotate clockwise to tighten the Sprinkler/Support Cup Assembly into the fitting. The W-Type 42 Wrench will accept a 1/2 in. ratchet drive. Note: Do not engage the sprinkler frame arms by the wrench, engage only the sprinkler wrench flats. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceil- ing installation and/or during applica- tion of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2 1/2 in. (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in con- tact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO Series LFII Residential Con- cealed Pendent Sprinklers (TY2534) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is an air gap between the lip of the Cover Plate and the ceiling. The Cover Plate assembly has a nominal 3/32 (2,4 mm) air gap, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situ- ation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-firecom.. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFll (TY2534) 4.9K Res- idential Concealed Pendent Sprinkler, P/N (specify): 155°F (68°C) ..................51 -549-1-155 200°F (93°C)..................51-549-1-200 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFll Concealed Sprinkler Cover Plate Assembly, temperature rating (specify), (specify) finish, P/N (specify): 139°F (59°C) Ivory (lRAL1015) ...............56-891-0-135 Bright Chrome ...............56-891-9-135B Beige (RAL1001)...............56-891-2-135 Pure White (RAL9O1O). .......... 56-891-3-135 Signal White (RAL9003)°° .......56-891-4-135 Grey White (RAL9002) ..........56-891-5-135 Brown (RAL8028)..............56-891-6-135 Black (RAL9005) ..............56-891-7-135 Brushed Brass ................56-891-8-135 Brushed Chrome ..............56-891-9-135 Custom Paint .................56-891-X-135 165°F (74°C) Ivory (RAL1015) ...............56-891-0-165 Bright Chrome ...............56-891-9-1658 Beige (RAL1001)...............56-891-2-165 Pure White (RAL9O1O). .......... 56-891-3-165 Signal White (RAL9003)**56-891-4-165 Grey White (RAL9002) ..........56-891-5-165 Brown (lRAL8028) .............. 58-891-6-165 Black (RAL9005) ..............56-891-7-165 Brushed Brass ................56-891-8-165 Brushed Chrome ..............56-891-9-165 Custom Paint .................56-891-X-165 * Eastern Hemisphere sales only ** Previously known as Bright White Note: All Custom Cover Plates are painted using SHERWIN-WILLIAMS Interior Latex Paint. Contact Johnson Controls Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 42 Sprinkler Wrench, P/N 56-000-1-079 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 ii ? 02022 Johnson Controls. All rights reserved. All specifications and other information shown wars current as of document revision date and are subject to change without notice. Johnson 11 ( NAtiONAL FIRE PROTECTiON ASSOCIATION c,d NFPA are rngistnred trednma,t,s Notional Fire Protection Asciotlon; TEFLON is e tr000mcr1, of T1, Chernoc,e Conrpuny FC, LLC SHERWIN-WILLIAMS iso rngisforrd fradenrarl, Of SWIMC LLC Controls tqC00 Worldwide Contacts I www.tyco-fire.com TFP446 Change History Appendix ISSUE DATE NOTES Page 1, updated OR code and URL; Page 4, changed corporate address and telephone number to 1467 08-22 Elmwood Avenue, Cranston, RI 02910 I Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700. Removed RAPID RESPONSE branding throughout; Page 1, Technical Data Approvals sub-section, 06-22 added Australian WaterMark Certified; Page 2, Technical Data Physical Characteristics sub-section, removed Ejection Spring; Pages 2 and 3, Figures 1 and 2, updated illustration to depict re-designed Bridge without Ejection Spring; Reduced page count to 4, formerly 6 pages in length. 11-21 Added OR code and URL to allow convenient access to electronic version from printed document. 09-21 New Technical Data Sheet TFP447 describes Rapid Response Series LFIl Residential TY2534 4.9 K-fac- tor Flat Plate Concealed Pendent Sprinkler. 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 Johnson 02022 Johnson Controls. All rights reserved. All specifications and other information Shown were Current at of document revision date and are subject to change Without notion. Controls • tqco® Worldwide www.tyco-fire.com Contacts Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp400 General Description TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers (TY2234) are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable Approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. Page 1 of 6 AUGUST 2022 TFP400 TFP400 Page, 2. of 6 7/16" (11,1 mm) 1/2" ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA._________ 1 - Frame 2 - Button MAKE IN SURFACE (73,0 mm) 4-Bulb 5 - Compression 2 2-1/4" Screw 6 - Deflector* 3 - Sealing Assembly 1 - t ESCUTCHEON (57,2 mm) 1-5/8° STYLE 20 (41,3 mm) WRENCH RECESSED * Temperature rating is 6* FLATS indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) ESM The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compli- ance with this document and the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe systems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 Australian WaterMark Certified Note: Sprinklers with a polyester finish are UL Listed as corrosion-resistant sprinklers. See the Design Criteria section for details on these approvals. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi/2 (70,6 LPM/bar'/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White Polyester Coated, Signal White Polyester Coated, or Chrome Plated Physical Characteristics Frame .............................Brass Button ...........................Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb (3 mm) ........................Glass Compression Screw .................Bronze Deflector ..........................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers are UL and C-UL Listed for instal- lation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R.. The number of design sprinklers speci- fied in NFPA 13D and 13R for wet pipe systems is to be applied when design- ing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. TFP400 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area () 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing Flow Pressure Flow Pressure ft x ft Ceiling Type ft (m x m) gpm psi gpm Psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 (3,7 x 3,7) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) Smooth Ceilings 1-1/4 in. to 4 in. 14 x 14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Ceilings per Recessed using Style 20 Escutcheon or 8 16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, (2,4) 18 X 18 17 12.0 17 12.0 1-1/4 in. to 13R, orl3 (5,5 X 5,5) (64,3) (0,83) (64,3) (0,83) 1-3/4 in. below bottom of beam. 20 X 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. For 'JFPA 13 residential applications, the greater of 0.1 gprn/ft° over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure (2)(3) Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area ( 155°F (68°C) 175°F (79°C) Minimum ftxft Deflector to Installation Spacing (m x m) Flow Pressure Flow Pressure Ceiling Type ft gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 in. to 4 in. 14 x 14 14 8.2 14 8.2 (43 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Ceilings Recessed using Style 20 Escutcheon or 8 6 x 16 15 9.4 15 9.4 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D or 13R non-recessed per NFPA 13D, (2,4) 18 X 18 18 13.5 18 13.5 1-1/4 in. to 13R, or 13 (5,5x5,5) (68,1) (0,93) (68,1) (0,93) 1-3/4 in. below bottom of beam. 20 X 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft° over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 4 of 6 2-7/8 DIA. (73,0 mm) 7/16±1/8 1/2 (12,7 mm) - (111±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER / MOUNTING FITTING PTE H-- . MOUNTING I ___ __ ___ / \t\ll.'J (3,2 1/8" SURFACE/ mm) /. .1-3/8"(34,9mm) CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII RESIDENTIAL PENDENT SPRINKLER A minimum discharge of 0.1 gpm/ft2 over the design area comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 in. to 4 in. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. Installation TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. 7CH RECESS ND "A USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 5 of 6 Care and Maintenance TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII 4.9K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .................51-201-1-155 Pure White (RAL 9010) Polyester12 ..................51-201-3-155 Signal White (RAL 9003) Polyester' ....................51-201-4-155 Chrome Plated ................51-201-9-155 175°F (79°C) Natural Brass .................51-201-1-175 Pure White (RAL 9010) Polyester1.2 ..................51-201-3-175 Signal White (RAL 9003) Polyester' ....................51-201-4-175 Chrome Plated ................51-201-9-175 UL Listed as corrosion-resistant. Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 02022 Johnson Controls. All rights macmad. All specifications and Other Information shown were current as of document revision data and are subjoctto change Without notice. Johnson NATiONAL FIRE PRoTECTiON ASSOCIATION and NFPA arc ocqistored trodernorks of hvtlovvl Fire Prorsotlon AsnooioIlvv TEFLON is Irodorrrortt of The Chevrourn Company FC, LLC Controls tqco® Worldwide Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp172 General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IA!Li)t(i The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT TY323.... Pendent 5.6K, 1/2 in. NPT Technical Data Approvals See Table A -. ,- ,1 :.. wT'1r; Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi½ (80,6 LPM/bar½) Temperature Rating See Table A Finishes Sprinkler: See Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb ................................Glass Compression Screw ..................Bronze Deflector ..........................Bronze Page 1 of 4 SEPTEMBER 2022 TFPI72 2 (50,8 mm) I 1-3/8 I (34,9 m WF _________ Fl DEFLECTOR * f'-.--- 2-7/8' (73,0 mm) DIA. TFPI 72 Page 2, of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16° (11,1 mm) Assembly 6 - Deflector * DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE - STYLE 15or20 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) 2-1/4" DIA. SPRINKLER FITTING FACE OF (57,2 mm) 5/8" (15,9 mm) FLUSH 3/8±5/16' I (9,5±7,9 mm) MOUNTING SURFACE/" - (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) (7,9:t6,4 mm) *(3,2 1/2" (12,7 mm) FLUSH MOUNTING " SURFACE/m) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON ,,~^WRENCH RECESS (USE ONLY END "A") FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3, of 4 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyesterc 5.6 1/2 in. NPT UPRIGHT (TY313) and PENDENT (TY323) ________________ 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY323) Figures 4a and 5b 135°F (57°C) Orange 1,2,3,4,7 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. EAC Approved. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire proteá- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench as shown in Figure 2. Apply the W-Type 6 Sprinkler Wrench to the wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench as shown in Figure 3. Apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI 72. Page 4 of 4 P/Na 77—XXX—X—XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS I 370 I 5.6K UPRIGHT (1/2 in.NPT) 1Y313 1 NATURAL BRASS 135 135°F (57°C) 371 5.6K PENDENT (1/2 in.NPT) TY323 POLYESTER PURE WHITE (RAL901O)a 155 155°F (68°C) Notes: a. Use suffix "I for ISO 7-1 connection; for example, 4 SIGNAL WHITE (RAL9003) 175 175°F (79°C) 77-370-4-175-I POLYESTER - JET BLACK (RAL9005) 200 200°F (93°C) POLYESTER 9 CHROME PLATED 286 286°F (141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet 1FP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 02022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision dale and are subject to change Without notice. Johnson 'I NATIONAL FIRE PnoTucnos ASSOCIATION and NFpAorv,00iotomd t,udr,00,kc of NMI onel Fire Pmfccon Aeeoclefion TEFLON iso fredernef, of The Chornoors Company FC, LLC Controls tqC00 Worldwide I www.tyco-fire.com Contacts TFPI 72 Change History Appendix ISSUE DATE NOTES 09-22 Page 1, updatedr OR code and URL; Page 3, Table A, added EAC Approved; Page 4, changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 I Telephone +1-401-781- 8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700. 11-21 Added OR code and URL to allow convenient access to electronic version from printed document. 08-18 Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer stating specifications and information subject to change without notice; Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300. 02-18 Changed Recessed Pendent (TY313) to Recessed Pendent (TY323) in Type column of Table A. 07-17 Added Table Ato organize Laboratory Listings and Approvals; Changed existing Part Number Selection table designation to Table B; Added Jet Black (RAL9005) Polyester sprinkler finish option. 02-14 Added note to indicate sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion Resistant Sprinklers; Added LPCB Approval. 01-13 Changed note in Ordering Procedure Part Number Selection table to indicate special order ISO thread sprinklers may be ordered by adding an I suffix code to Part Numbers, formerly described as prefix. 12-12 Rev A Added C-UL Listings and reference to Intermediate Level sprinkler data sheets. 12-12 New Technical Data Sheet TFP172 describes Series TY-FRB Quick Response 5.6 K-factor (K80) Stan- dard Coverage TY313 Upright and TY323 Pendent and Recessed Pendent Sprinklers 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 0 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current on of document revision date and are Subject to change without notice. Johnson 'Jj Controls