Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2820 LOKER AVE; E; FPC2022-0192; Permit
PIEXT REPORT (L'City of Carlsbad I • 1:ic .w 4 Print Date: 03/24/2025 Permit No: FPC2022-0192 Job Address: 2820 LOKER AVE E, CARLSBAD, CA 92010-6608 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090831500 Track #: Applied: 10/13/2022 Valuation: $4,128,299.92 Lot #: Issued: 12/15/2022 Occupancy Group: Project #: DEV2022-0135 Finaled Close Out: 08/19/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Cheung, Nathaniel Project Title: ABSORPTION SYSTEMS Description: ABSORPTION SYSTEMS -REPLACE 548 ESFR HEADS TO REGULAR PENDENTS, ADD 6 DRY PENDENT ON LOW TEMP SPACE, ADD HEADS IN OFFICE/CORRIDOR AREAS Applicant: FPContractor: STEPHEN KOVACS TITAN FIRE PROTECTION INC 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services (first hour) $188.00 FIRE Hourly Services (first hour) $188.00 FIRE NFPA 13 or 13R System > 100 heads $774.00 Total Fees: $1,150.00 Total Payments To Date: $1,150.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Hydraulic Calculations for Project Name: ABSORPTION SYSTEMS-PHASE 2 Location: 2820 LOKER AVE, CARLSBAD CA 92010 Drawing Name: Design Remote Area Number: 3 Calculation Date: 10/4/2022 Occupancy Classification Ordinary Group I- AREA#3 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.15gpm/ft2 1500ft2 (Actual 1523ft2) 130ft2 Pendent 16 0 N/A gpm at Node: N/A 250.00 at Node: 1 Type Allowance at Source (Safety Margin = 93.129) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 592.67 @ 29.830 Type of System: WET Name of Contractor: TITAN FIRE PROTECTION Address: 1341 DISTRUBTION DRIVE, VISTA CA 92081 Phone Number: Name of designer: NM Authority Having Jurisdiction: CITY OF CARLSBAD Notes Automatic peaking results Left: N/A Right: N/A M.E.P.CAD, Inc. AutoSPRINK 2020 06.3.9.0 10/4/2022 8:10:57AM Page 1 13,9 12( 10 9c (I, 0. 75 a, 6C 45 45 30 15 0 Job Name: Remote Area Number: 150- Water f Supply mary Sheet Sum Node: I Available Static 592.67 4 Pressure Supply g 122.95— 123.000 000.00 @iiaoo - 426729.830 592.67 with Hose Allowance at Source System demand curve 1IJJJLj_jILIIIIFI-I IIIILII [II iiirt L ILL III I I I II I I I I I I I I I I I I (1_. 3100 .... 6200 _... 9300 12400 155 Hydraulic Graph N 1.85 Date: 10/4/2022 Do Flow - gpm (,© M.E.P.CAD, Inc. 0 AutoSPRINK 2020 06.3.9.0 10/4/2022 8:10:59AM Page 2 1111 Summary Of Outfiowing Devices Job Number: 1 Report Description: Ordinary Group I- AREA#3 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 2480 19.50 19.50 5.6 12.125 Sprinkler 2481 21.98 19.50 5.6 15.404 Sprinkler 2482 22.20 19.50 5.6 15.709 Sprinkler 2483 21.99 19.50 5.6 15.415 Sprinkler 2554 19.54 19.50 5.6 12.177 Sprinkler 2555 21.93 19.50 5.6 15.342 Sprinkler 2556 22.16 19.50 5.6 15.663 Sprinkler 2557 21.96 19.50 5.6 15.381 Sprinkler 2606 19.53 19.50 5.6 12.164 Sprinkler 2607 21.97 19.50 5.6 15.391 Sprinkler 2608 22.15 19.50 5.6 15.651 Sprinkler 2609 21.96 19.50 5.6 15.384 Sprinkler 2649 19.71 19.50 5.6 12.392 Sprinkler 2650 21.96 19.50 5.6 15.378 Sprinkler 2651 22.18 19.50 5.6 15.686 Most Demanding Sprinkler Data f, © M.E.P.CAD, Inc. AutoSPRlNK 2020 v16.3.9.0 10/4/2022 8:11:00AM Page 3 Job Name: Remote Area Number: Date: 10/4/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 123.000 118.000 8000.00 122.959 592.67 29.830 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 4-2 Supply 29.830 342.67 2480 9-0 Sprinkler 12.125 19.50 2481 9-0 Sprinkler 15.404 21.98 2482 9-0 Sprinkler 15.709 22.20 2483 9-0 Sprinkler 15.415 21.99 2554 9-0 Sprinkler 12.177 19.54 2555 9-0 Sprinkler 15.342 21.93 2556 9-0 Sprinkler 15.663 22.16 2557 9-0 Sprinkler 15.381 21.96 2606 9-0 Sprinkler 12.164 19.53 2607 9-0 Sprinkler 15.391 21.97 2608 9-0 Sprinkler 15.651 22.15 2609 9-0 Sprinkler 15.384 21.96 2649 9-0 Sprinkler 12.392 19.71 2650 9-0 Sprinkler 15.378 21.96 2651 9-0 Sprinkler 15.686 22.18 2652 9-0 Sprinkler 15.341 21.93 3 4-2 29.262 6 4-2 29.788 ,© M.E.P.CAD, Inc. iffiAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:01AM Page 4 Job Name: Remote Area Number: Date: 10/4/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 7 4-2 29.352 9 4-2 29.701 10 3-0 26.625 189 2961/2 12.647 191 29'9h/2 12.568 193 30-0 12.558 195 30-3 12.657 197 30-6 12.713 199 30-9 12.736 201 31-0 12.733 203 31-3 12.711 205 3151/2 12.676 207 31-3% 12.805 209 31-1 12.949 211 30-10 13.085 213 30-7 13.213 215 3041/2 13.337 217 30-2 13.449 219 29-11 13.562 221 2981/2 13.670 223 29-6 13.757 225 29-3% 13.845 271 30-11% 11.429 ,© M.E.P.CAD, Inc. 40 AutoSPRlNK 2020 v16.3.9.0 10/4/2022 8:11:01AM Page 5 Job Name: Remote Area Number: Date: 10/4/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 273 30'-6 11.541 275 30-9 11.438 277 30'-3 6.933 373 30-9 11.328 375 30-11% 11.313 377 30-6 11.433 379 30'-3 6.997 452 30-6 11.430 454 30-3 7.190 456 30-111A 11.309 466 30-9 11.325 522 30-3 7.486 524 30-9 11.357 528 30-6 11.464 532 30-11% 11.340 1121 29'-3% 13.632 1123 2961/2 13.529 1125 29-9% 13.429 1127 30-0 13.333 1129 30-3 13.242 1131 30-6 13.153 1133 30'-9 13.066 1135 31-0 12.981 ,© M.E.P.CAD, Inc. MAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:01AM Page 6 Job Name: Remote Area Number: Date: 10/4/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1137 31'-3 12.897 1139 3151/2 12.820 1141 31-3% 12.918 1143 31-1 13.043 1145 30-10 13.169 1147 30'-7 13.296 1149 3041/2 13.424 1151 30-2 13.547 1153 29-11 13.677 1155 2981/2 13.809 1157 29-6 13.921 1159 2931/2 14.037 ,© M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:01AM Paqe 7 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) ___________ Fitting/Device (Equivalent (q) Equiv. Length) Fixed Pressure Losses, Fitting (Foot) __________ Pf Friction Elev(Pe) ________________ Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total (Foot) (Q) (Foot) (Foot) (psi) Friction( directly to (Pt) and shown as 2480 9-0 5.6 19.50 1 (See 23-4 120 12.125 Route ..... Notes) Sprinkler, 9-0 -9.209 277 30-3 19.50 1.0490 0.124177 2E(2'-O), T(5'-O) 32-4 4.017 277 30-3 2 1401/2 120 6.933 0.004566 1401/2 379 30'-3 19.50 2.0670 0.064 379 30-3 19.54 2 11-8 120 6.997 Flow (q) from Route 3 0.016492 11-8 454 30-3 39.04 2.0670 0.193 454 30-3 19.53 2 8-6 120 7.190 Flow (q) from Route 2 0.034929 522 30-3 58.57 2.0670 8-6 0.297 522 30-3 19.71 2 (See 75- 11 120 7.486 Flow (q) from Route 4 20-0 0.415 Notes) 1121 29-3% 78.29 2.0670 0.059739 1(10-0), P0(10-0) 95-11 5.731 1121 2931/2 6 10-0 120 13.632 -0.105 1123 29-6 V2 78.29 6.3570 0.000251 101-0 0.003 1123 2961/2 39.97 6 10-0 120 13.529 Flow (q)from Route 7 -0.105 1125 29-9% 118.26 6.3570 0.000539 10'-O 0.005 1125 29-9% 40.04 6 10'-O 120 13.429 Flow (q) from Route 13 -0.105 1127 30'0 158.30 6.3570 0.000924 10-0 0.009 1127 30-0 39.04 6 10-0 120 13. 333 Flow (q) from Route 5 -0.105 1129 30-3 197.34 6.3570 0.001390 10-0 0.014 1129 30'3 17.35 6 10-0 120 13. 242 Flow (q)from Route 32 -0.105 1131 30'-6 214.69 6.3570 10,0 0.001624 0.016 1131 30-6 14.87 6 10,-U 120 13.153 Flow (q)from Route 6 -0.105 1133 30-9 229.56 6.3570 0.001839 10-0 0.018 © M.E.P.CAD, Inc. iSAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 8 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information El v1 es Flow added Fitting & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) _______________ (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total (Foot) (Q) (Foot) (Foot) (psi) Friction( directly to (PQ and shown as 1133 30'-9 12.73 6 10-0 120 13. 066 Flow (q) from Route 36 -0.105 1135 31'O 242.30 6.3570 0.002032 10-0 0.020 1135 31-0 10.89 6 10-0 120 981 Flow (q) from Route 33 -0.105 1137 31-3 253.19 6.3570 0.002204 10-0 0.022 1137 31-3 9.34 6 9-6 120 12.897 Flow (q) from Route 29 -0.100 1139 315h/2 262.53 6.3570 0.002357 9-6 0.022 1139 315h/2 8.13 6 91-11 1/2 120 12.820 Flow (q) from Route 31 0.074 1141 3131/2 270.66 6.3570 0.002494 9111/2 0.025 1141 3131/2 7.15 6 9-6 120 12.918 Flow (q) from Route 27 0.100 1143 31-1 277.81 6.3570 0.002617 9-6 0.025 1143 31-1 6.49 6 9-6 120 043 Flow (q) from Route 24 0.100 1145 30-10 284.30 6.3570 0.002731 9-6 0.026 1145 30-10 6.11 6 951/2 120 13.169 Flow (q) from Route 25 0.100 1147 30-7 290.41 6.3570 .002840 0.002840 '-5 951/ 0.027 1147 30-7 6.02 6 9-6 120 13.296 Flow (q) from Route 21 0.100 1149 3041/2 296.43 6.3570 0.002950 9-6 0.028 1149 304h/2 6.21 6 9'Q1/2 120 13.424 Flow (q) from Route 22 0.095 1151 30-2 302.64 6.3570 0.003066 90h/2 0.028 1151 30-2 6.61 6 9-6 120 13. 547 Flow (q) from Route 19 0.100 1153 29-11 309.24 6.3570 0.003191 9-6 0.030 1153 29-11 7.22 6 951/2 120 13.677 Flow (q) from Route 39 0.100 1155 298h/2 316.47 6.3570 0.003330 9-5V 0.032 , © M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 9 Job Name: Remote Area Number: Date: 10/4/2022. Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) __________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 1155 2981/2 7.98 6 8-0 120 13.809 Flow (q) from Route 20 0.003487 0.084 1157 29-6 324.45 6.3570 8-0 0.028 1157 29-6 8.71 6 821/2 120 13.921 Flow (q) from Route 17 0.003662 0.086 1159 2931/2 333.16 6.3570 82h/2 0.030 1159 2931/2 9.51 6 (See Notes) 80'7 120 14.037 Flow (q) from Route 18 3E(17'-7), CV(40-3), BV(12'-7) 105'-7% 0.003858 14.506 3 4-2 342.67 6.3570 186-21/2 0.718 3 4-2 6 (See Notes) 691/2 150 29.262 E(21-7) 21-7 0.003146 0.001 7 4-2 342.67 6.0900 28-41/2 0.089 7 4-2 8 (See Notes) 359'0 150 29.352 2E(27-2) 0.000844 -0.000 9 4-2 342.67 7.9800 413-3% 0.349 9 4-2 8 (See Notes) 7'2 120 29.701 E(21-1%) 2i11/z 0.001085 -3.107 10 3'-0 342.67 8.2490 28-3% 0.031 10 3-0 8 (See Notes) 14'0 140 26.625 BFP, 2E(30-6%) 61'-1 0.000751 3.107 6 4-2 342.67 8.3900 75-1 0.056 6 4-2 8 (See Notes) 22'7% 150 29.788 E(27'-2), S 27-2 0.000844 0.000 1 -4-2 342.67 7.9800 49'-9% 0.042 250.00 29.830 Hose Allowance At Source Total(Pt) Route I 1 592.67 2606 9-0 5.6 19.53 1 (See Notes) 23'-0 120 12.164 Route 2••••• Sprinkler, 3E(2'-O), P0(5-0) 0.124547 -9.209 454 30-3 19.53 1.0490 34-0 4.234 7.190 Total(Pt) Route 2 2554 91-0 5.6 19.54 1 (See Notes) 23'4 1 120 12.177 1 Route ..... 1 Sprinkler, 2E(2-0), P0(5-0) t 0.124663 -9.209 379 30'-3 19.54 1.0490 324 4.029 , © M.E.P.CAD, Inc. Q AutoSPRINK 2020 v16.3.9.0 10/4/2022 8:11:03AM Page 10 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total ________________ Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pt) and shown as (Foo t) 6.997 J Total(Pt) Route 3 2649 9-0 5.6 19.71 1 (See 22-11% J 120 12.392 Route 4•"•• Sprinkler, u-c) 1 -9.209 Notes) 522 30'-3 19.71 1.0490 0.126700 3E(2'-O), P0(5-U) 33-11% 4.303 7.486 Total(Pt) Route 4 2652 9-0 5.6 21.93 1 (See 249h/2 120 15.341 Route 5..... Sprinkler, -9.525 Notes) 532 30-11% 21.93 1.0490 0.154366 3E(2'-O), P0(5-0) 35-9 1/2 5.524 532 30-111/2 17.11 2 (See 76-8 120 11.340 Flow (q) from Route 9 20'-0 0.415 Notes) 1127 30-0 39.04 2.0670 0.016493 T(10'-O), P0(10-U) 96-8 1.578 13.333 Total(Pt) Route 5 2555 9-0 5.6 21.93 1 (See 24-0 120 15.342 "•• Route 6 ..... Notes) Sprinkler, -9.314 377 30-6 21.93 1.0490 0.154368 3E(2'-O), P0(5-0) 35-0 5.406 377 30-6 3.96 2 14-0 120 11.433 Flow (q) from Route 37 0.007715 273 30-6 25.89 2.0670 14-0 0.108 273 30-6 21.98 2 (See 8'g 120 11.541 Flow (q) from Route 11 20-0 0.415 Notes) 189 29-6% 47.87 2.0670 0.024049 T(10'-O), P0(10-0) 28'-9 0.691 189 29-6% 3 101-0 120 12.647 -0.105 191 29-9% 47.87 3.2600 0.002615 10-0 0.026 191 29-9% 48.65 3 10-0 120 12.568 Flow (q) from Route 14 -0.105 193 30-0 96.52 3.2600 0.009569 10'-O 0.096 193 30-0 48.80 3 101-0 120 12.558 Flow (q) from Route 8 -0.105 195 30-3 145.33 3.2600 0.020400 10-0 0.204 195 30'-3 3 101-0 120 12.657 -0.105 197 30-6 127.98 3.2600 0.016124 10-0 0.161 &©M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 11 Job Name: Remote Area Number: Date: 10/4/2022. Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) __________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 197 30-6 2 (See Notes) I 118.111/2 120 12.713 P0(10-0) 2T(10'-O), P0(10-0) 40'0 0.002766 0.000 1131 30-6 14.87 2.0670 158-11% 0.440 13.153 Total(Pt) Route 6 2650 9-0 5.6 21.96 1 (See Notes) 23-11 120 15.378 ••"• Route 7..... Sprinkler, 3E(2'-O), P0(5-0) 0.154704 -9.314 528 30'-6 21.96 1.0490 34-11 5.401 528 30'-6 18.01 2 (See Notes) 75-9% 120 11.464 Flow (q) from Route 10 T(10'-O), PO(10'-O) 2-0 0.017226 0.415 1123 29-6% 39.97 2.0670 ~975"9% 1.650 13.529 Total(Pt) Route 7 2557 9-0 5.6 21.96 1 (See Notes) 24-3% 120 15.381 ••••• Route 8..... Sprinkler, 3E(2-0), P0(5-0) 11-0 0.154729 -9.525 375 30-111/2 21.96 1.0490 35'-3% 5.458 375 30-11% 4.86 2 1401/2 120 11.313 Flow (q) from Route 38 0.008232 271 30-111/2 26.82 2.0670 1401/2 0.116 271 30-11% 21.99 2 (See Notes) 8'.8 120 11.429 Flow (q) from Route 12 T(10'-O), PO(10'-O) 20-0 0.024923 0.415 193 30-0 48.80 2.0670 28-8 0.714 12.558 TTotal(Pt) Route 8 2609 91-0 5.6 21.96 1 (See Notes) 24-2% 120 15.384 "" Route 9••••• Sprinkler, 3E(2-0), P0(5-0) 0.154762 -9.525 456 30111/2 21.96 1.0490 35 21/2 5.450 456 30111/2 2 8-9 120 11.309 0.003584 532 30'-11% 17.11 2.0670 8-9 0.031 11.340 Total(Pt) Route 9 2607 9-0 5.6 21.97 1 (See Notes) 23-7 120 15.391 Route 10 ..... Sprinkler, 3E(2'-O), P0(5-C) 0.154830 -9.314 452 30-6 21.97 1.0490 34-7 5.353 &@ M.E.P.CAD, Inc. JAutoSPRlNK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 12 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a r'•g'•" Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) _______________ _ Friction(Pt) _______ 452 _____________ 30-6 _______ 2 8-8 120 11.430 0.003942 528 30-6 18.01 2.0670 8-8 0.034 11.464 Total(Pt) Route 10 2481 9-0 5.6 21.98 1 (See Notes) 24'-2 120 15.404 ••-• Route 11•••• Sprinkler, 3E(2'-O), P0(5-0) 0.154951 -9.314 273 30-6 21.98 1.0490 35-2 5.451 11.541 Total(Pt) Route 11 2483 9-0 5.6 21.99 1 (See Notes) 24-81/2 120 15.415 Route 12 ..... Sprinkler, 3E(2'-O), P0(5-0) 0.155052 -9.525 271 30-111/2 21.99 1.0490 35-8 % 5.539 11.429 Total(Pt) Route 12 2608 9-0 5.6 22.15 1 (See Notes) 23'-4/2 120 15.651 ..... Route 13 ..... Sprinkler, 2E(2'-O), P0(5-0) 9-0 0.157241 -9.420 466 30-9 22.15 1.0490 32-4% 5.094 466 30-9 2 8'-5 120 11.325 0.003882 524 30-9 17.86 2.0670 8-5 0.033 524 30-9 22.18 2 (See Notes ) 76101/2 120 11.357 Flow (q) from Route 15 T(10'-O), PO(10'-0) 20-0 0.017282 0.415 1125 29-9% 40.04 2.0670 96-101/2 1.657 13.429 Total(Pt) Route 13 2556 9-0 5.6 22.16 1 (See Notes) 23-3% 120 15.663 Route 14 ..... Sprinkler, 2E(2'-O), P0(5-C) 9-0 0.157359 -9.420 373 30'-9 22.16 1.0490 32-3% 5.084 373 30'-9 4.29 2 13-9 120 11.328 Flow (q) from Route 35 0.008028 275 30-9 26.45 2.0670 13-9 0.110 275 30-9 22.20 2 (See Notes) 8'10 120 11.438 Flow (q) from Route 16 T(10'-O), PO(10'-0) 20-0 r28-10 0.024777 0.415 191 29-9% 48.65 2.0670 0.714 12.568 Total(Pt) Route 14 ©M.E.P.CAD, Inc. AutoSPRlNK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 13 Job Name: Remote Area Number: Date: 10/4/2022. Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 2651 91-0 5.6 22.18 1 (See Notes) 233h/2 120 15.686 ••"• Route I5 ..... Sprinkler, 2E(2-O), P0(5-0) 0.157572 -9.420 524 30-9 22.18 1.0490 32 31/2 5.091 11.357 Total(Pt) Route 15 2482 9-0 5.6 22.20 1 (See T Notes) 23-7% 120 15.709 "" Route 16 ..... Sprinkler, 2E(2'-O), P0(5-0) I 91-0 0.157784 -9.420 275 30-9 22.20 1.0490 I 32-7% 5.149 11.438 Total(Pt) Route 16 221 29-8% 3 8-0 120 13.670 "" Route 17..... 0.000438 0.084 223 29-6 18.22 3.2600 8-0 0.004 223 29-6 2 (See Notes) 118'11% 120 13.757 P0(10-0) 2T(10'-O), P0(10-0) 40-0 0.001028 -0.000 1157 29'-6 8.71 2.0670 158-11% 0.163 13.921 Total(Pt) Route 17 223 29-6 871 3 8'-21/2 120 13.757 Route 18 ..... Flow (q) from Route 17 0.000132 0.086 225 29-3% 9.51 3.2600 8-2% 0.001 225 29-3% 2 (See Notes) 118'-111/2 120 13.845 P0(10-0) 2T(10-0), P0(10-0) 40'-O 0.001210 -0.000 1159 29-3% 9.51 2.0670 158-111/2 0.192 14.037 Total(Pt) Route 18 217 30-2 40.03 2 (See Notes) 118-11% 120 13.449 Route 19 ..... PO(10'-O), Flow (q) from Route 23 2T(10'-O), P0(1 0-U) 40-0 0.000617 % ______________ 1151 30-2 6.61 2.0670 158-11 0.098 13.547 Total(Pt) Route 19 217 30-2 40.03 3 9'-6 120 13.449 ••••• Route 2O•"•. Flow (q) from Route 23 0.001345 0.100 219 29-11 33.42 3.2600 9-6 0.013 219 29-11 3 9-5% 120 13.562 0.000857 0.100 221 29-8% 26.20 3.2600 9-5% 0.008 ,©M.E.P.CAD, Inc. a AutoSPRlNK 2020 v16.3.9.0 10/4/2022 8:11:03AM Page 14 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total ________________ (Foot) (Q) (Foot) (psi) Friction(Pf) directly to (Pt) and shown as (Foot) npin, 221 29-8% 2 (See J 118'-1W2 120 13.670 Notes) P0(10-0) 40-0 -0.000 1155 29'-8Y2 7.98 2.0670 I 0.000874 2T(10-0), P0(10-0) 158-11/ 0.139 13.809 Total(Pt) Route 20 213 30'-7 52.26 2 (See I 118-11% 120 13.213 "" Route 21 ..... Notes) P0(10'-O), Flow (q) from Route 26 40'O 0.000 ______________ 1147 30-7 6.02 2.0670 0.000519 / 2T(10-0), P0(10-0) 158-11 0.083 13.296 Total(Pt) Route 21 213 30-7 52.26 3 9-6 120 13.213 ..... Route 22..... Flow (q) from Route 26 0.100 215 30-4'/2 46.24 3.2600 0.002452 9-6 0.023 215 3041/2 2 (See 118111/2 120 13.337 PO(10'-O) 40'-O 0.000 Notes) 1149 3041,4 6.21 F2.0670 0.000549 2T(10'-O), P0(10-0) 158-11% 0.087 13.424 Total(Pt) Route 22 215 3041/2 6.21 3 1 9-0% 120 13.337 Route 23 ..... Flow (q) from Route 22 0.095 217 30-2 40.03 3.2600 0.001878 90/2 0.017 13.449 Total(Pt) Route 23 209 31'-1 64.86 2 (See 118'-11% 120 12.949 Route 24 ..... Notes) P0(10-0), Flow (q) from Route 28 40'O 0.000 ______________ 1143 31-1 6.49 2.0670 0.000596 % 2T(10'-O), P0(10-0) 158-11 0.095 13.043 Total(Pt) Route 24 209 31-1 64.86 3 9-6 120 12.949 Route 25 ..... Flow (q) from Route 28 0.100 211 30-10 58.37 3.2600 0.003773 9-6 0.036 211 30-10 2 (See 118'11% 120 13.085 PO(10'-O) 40-0 0.000 Notes) 1145 30-10 6.11 2.0670 0.000533 2T(10'-O), P0(10-0) 158-111/2 0.085 13.169 Total(Pt) Route 25 211 30-10 6.11 3 9'-5% 120 13.085 Route 26 ..... Flow (q) from Route 25 0.100 213 30-7 52.26 3.2600 0.003075 9-5% 0.029 (.,©M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 15 Job Name: Remote Area Number: Date: 10/4/2022' Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 13.213 Total(Pt) Route 26 207 31-3% 72.00 2 (See Notes) I 118'-11'/2 120 12.805 "•• Route 27..... P0(10-0), Flow (q) from Route 30 2T(10'-O), P0(10-0) t 40-0 0.000713 % 0.000 ______________ 1141 3131/2 7.15 2.0670 158-11 0.113 12.918 Total(Pt) Route 27 207 31-3% 72.00 3 9-6 120 12.805 "•• Route 28..... Flow (q) from Route 30 0.004585 0.100 209 31-1 64.86 3.2600 9-6 0.044 12.949 Total(Pt) Route 28 203 31-3 89.48 2 (See Notes) 118'-11% 120 12.711 •••' Route 29..... P0(10-0), Flow (q) from Route 34 2T(10'-O), P0(1 0-a) b 40'-O 0.001170 0.000 1137 31-3 9.34 2.0670 158-111/2 ______________ 0.186 12.897 Total(Pt) Route 29 203 31'-3 89.48 3 9-6 120 12.711 Route 30 ..... Flow (q) from Route 34 0.006782 -0.100 205 31-5% 80.14 3.2600 9-6 0.064 205 31-5% 3 911h/2 120 12.676 0.005564 0.074 207 31-3% 72.00 3.2600 9-11% 0.055 12.805 Total(Pt) Route 30 205 31-51/2 2 (See Notes) J 118'11% 120 12.676 '••• Route 31..... P0(10-0) 2T(10'-O), P0(10-0) F 40-0 0.000906 0.000 1139 31-5% 8.13 2.0670 I 158-11% 0.144 12.820 Total(Pt) Route 31 195 30-3 2 (See Notes) I 118'111/2 120 12.657 Route 32 ..... P0(10-0) 2T(10-0), P0(10-0) t 40'-0 0.003678 0.000 1129 30-3 17.35 2.0670 158-11% 0.585 13.242 Total(Pt) Route 32 197 30'-6 14.87 3 T o'-o 120 T 12.713 ••••• Route 33..... Flow (q) from Route 6 0.012830 -0.105 199 30'-9 113.10 3.2600 10-0 0.128 &©M.E.P.CAD, Inc. InAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 16 1 Job Nme: 'Remote Area Number: Date: 10/4/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 199 30-9 3 10,-0 120 12.736 0.010287 -0.105 201 31-0 100.37 3.2600 10,-a 0.103 201 31-0 2 (See Notes) 118111/2 120 12.733 PO(1O'-O) 2T(10-0), P0(10-0) 40-0 0.001555 0.000 1135 31-0 10.89 2.0670 158'-111/2 0.247 12.981 Total(Pt) Route 33 201 31-0 10.89 3 10-0 120 12.733 ••••• Route 34 ..... Flow (q) from Route 33 0.008317 -0.105 203 31'-3 89.48 3.2600 10-0 0.083 12.711 Total(Pt) Route 34 466 30-9 17.86 2 12'-1 120 11.325 Route 35..... Flow (q) from Route 13 0.000278 373 30-9 4.29 2.0670 12-1 0.003 11.328 Total(Pt) Route 35 199 30'-9 2 (See Notes) 118-111/2 120 12.736 ' Route 36 ..... P0(10-0) 2T(10'-O), P0(10-0) 40'-0 0.002075 0.000 1133 30-9 12.73 2.0670 158-111/2 0.330 13.066 Total(Pt) Route 36 452 30-6 18.01 2 1191/2 120 11.430 Route 37 ..... Flow (q) from Route 10 0.000239 377 30-6 3.96 2.0670 11-9% 0.003 11.433 Total(Pt) Route 37 456 30'-111/2 17.11 2 11-10% 1 120 11.309 ••••• Route 38 ..... Flow (q) from Route 9 0.000349 375 30-11% 4.86 2.0670 11-10% 0.004 11.313 Total(Pt) Route 38 219 29-11 2 (See Notes) 118-111/2 1 120 13.562 "" Route 39..... P0(10-0) 2T(10'-O), P0(10-0) 40'0 t 0.000727 -0.000 1153 29-11 7.22 2.0670 158-111/2 0.116 13.677 Total(Pt) Route 39 LAk © M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:11:03AM Page 17 Job Name: Remote Area Number: Date: 10/4/2022' Equivalent Pipe Lengths of Valves and Fittings (C=120 only) (C Value Multiplier I Actual Inside Diameter 4.87 Factor Value Of C 100 130 140 150 I \ Schedule 40 Steel Pipe Inside Diameter J Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Car, ,© M.E.P.CAD, Inc. QMAutoSPRINK 2020 v16.3.9.0 10/4/2022 8:11:03AM Page 18 Hydraulic Calculations for Project Name: ABSORPTION SYSTEMS-PHASE 2 Location: 2820 LOKER AVE, CARLSBAD CA 92010 Drawing Name: Design Remote Area Number: 2 Calculation Date: 10/4/2022 Occupancy Classification Ordinary Group l-AREA#2 Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.15gpm/ft2 1500ft2 (Actual 877ft2) 130ft2 Pendent 11 0 N/A gpm at Node: N/A 250.00 at Node: I Type Allowance at Source (Safety Margin = 98.976) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 468.41 @23.997 Type of System: Name of Contractor: TITAN FIRE PROTECTION Address: 1341 DISTRUUTION DRIVE, VISTA CA 92081 Phone Number: Name of designer: NM Authority Having Jurisdiction: CITY OF CARLSBAD Notes Automatic peaking results Left: 23.997 Right: 23.997 © M.E.P.CAD, Inc. :AutoSpRlNK 2020 06.3.9.0 10/4/2022 8:23:04AM Page 1 Flow -gpm (hA,.@ M.E.P.CAD, Inc. AutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:05AM Paqe 2 Job Name: Remote Area Number: 150- 105 13E 120 59 30 15 60 90 Water Supply Sum Node: I mary Sheet Available Supply - Static Pressure 123.000 168.41 IM 122.974- 000.00 @110.0000 18.41 23.997 468.41 with Hose Allowance at Source System demand curve_______ I.L.L.j.L. ._(1IIIItLt tIIIIIII IIIIIt ItIllIll 11111111 11111 II II I I I I I I Cl 3100 6200 _. 9300 12400 15 Hydraulic Graph N 1.85 Date: 10/4/2022 Job Name: Remote Area Number: Date: 10/4/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 123.000 118.000 1 8000.00 122.974 468.41 23.997 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4-2 Supply 23.997 218.41 3208 9-0 Sprinkler 12.125 19.50 3209 9-0 Sprinkler 12.512 19.81 3227 9-0 Sprinkler 12.282 19.63 3228 9-0 Sprinkler 12.293 19.63 3229 9-0 Sprinkler 12.133 19.51 3297 9-0 Sprinkler 12.935 20.14 3298 9-0 Sprinkler 12.914 20.12 3325 9-0 Sprinkler 12.454 19.76 3326 9-0 Sprinkler 12.568 19.85 3327 9-0 Sprinkler 12.877 20.10 3342 9-0 Sprinkler 13.217 20.36 2 4-2 23.752 4 4-2 23.791 6 4-2 23.979 9 4-2 23.941 10 3-0 20.848 1318 28-5 8.382 1319 28-5 8.390 ,© M.E.P.CAD, Inc. 3AutoSPRlNK 2020 06.3.9.0 10/4/2022 8:23:08AM Paqe 4 Job Name: Remote Area Number: Date: 10/4/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1329 28-8 8.386 1341 29-2 8.258 1347 28-11 8.357 1365 28-8 8.391 1375 29-2 8.263 1383 28-11 8.362 1388 28-5 8.447 1389 28-5 8.475 1417 28-8 8.405 1446 28-5% 8.799 1500 2751/2 9.298 1502 27-6 9.277 1503 28-8 8.697 1504 27-8% 9.195 1673 2781/2 9.241 1674 27-101/2 9.178 1676 27'111/2 9.139 (,© M.E.P.CAD, Inc. AutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:08AM Page 5 Job Name: Remote Area Number: Date: 10/4/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 123.000 118.000 8000.00 122.974 468.41 23.997 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4-2 Supply 23.997 218.41 3208 9-0 Sprinkler 12.125 19.50 3209 9-0 Sprinkler 12.512 19.81 3227 9-0 Sprinkler 12.282 19.63 3228 9-0 Sprinkler 12.293 19.63 3229 9-0 Sprinkler 12.133 19.51 3297 9-0 Sprinkler 12.935 20.14 3298 9-0 Sprinkler 12.914 20.12 3325 9-0 Sprinkler 12.454 19.76 3326 9-0 Sprinkler 12.568 19.85 3327 9-0 Sprinkler 12.877 20.10 3342 9-0 Sprinkler 13.217 20.36 2 4-2 23.752 4 4-2 23.791 6 4-2 23.979 9 4-2 23.941 10 3-0 20.848 1318 28-5 8.382 1319 28-5 8.390 ,©M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:08AM Page 4 Job Name: Remote Area Number: Date: 10/4/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1329 28-8 8.386 1341 29-2 8.258 1347 28-11 8.357 1365 28'-8 8.391 1375 29-2 8.263 1383 28-11 8.362 1388 28-5 8.447 1389 28-5 8.475 1417 28'-8 8.405 1446 28'-5V2 8.799 1500 27-5 V2 9.298 1502 27-6 9.277 1503 28'-8 8.697 1504 2781/2 9.195 1673 27-8% 9.241 1674 27-10% 9.178 1676 27'-111/2 9.139 &©M.E.P.CAD, Inc. AfflAutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:08AM Page 5 Job Name: 'Remote Area Number: Date: 10/4/2022 Pipe Information El v1 Flow added Fittings & Length C Factor Total(Pt) Notes Node I e ot) (Fo K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) ___________ Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total ________________ (Foot) (Foot) (Foot) (psi) Friction(Pt) directly to (Pt) and shown as 3208 91-0 5.6 19.50 1 (See 26'-8 120 12.125 Route I Notes) Sprinkler, -8.420 1318 28-5 19.50 1.0490 0.124177 3E(2'-O), P0(5-0) 37-8 4.677 1318 28-5 21/2 5-8 120 8.382 0.001400 1319 28-5 19.50 2.6350 5 -8 0.008 1319 28-5 19.81 21/2 (See 8 41/2 120 8.390 Notes) Flow (q) from Route 6 8-3 1389 28'-5 39.31 2.6350 0.005120 E(8'-3) 16-7% 0.085 1389 28-5 20.14 2% (See 12'-4/2 120 8.475 Notes) Flow (q) from Route 10 24-8% 0.415 1500 2751/2 59.45 2.6350 0.011006 E(8'-3), P0(16-5%) 37-1 0.408 1500 2751/2 6 2-0 120 9.298 -0.021 1502 27'-6 59.45 6.3570 0.000151 2-0 0.000 1502 27-6 20.36 6 8-0 120 9.277 Flow (q) from Route 11 -0.084 1504 27-8% 79.81 6.3570 0.000260 8-0 0.002 1504 27-8% 37.75 6 (See 30'-6 120 9.195 Notes)55-4 Flow (q) from Route 3 - -0.063 1674 27-101/2 117.56 6.3570 0.000533 E(17'-7), T(37'-8%) 85-10 0.046 1674 27'- 101/2 21.76 6 4-0 120 9.178 Flow (q) from Route 12 -0.042 1676 27-11% 139.32 6.3570 0.000730 4-0 0.003 1676 27111/2 39.49 6 10,-U 120 9.139 Flow (q) from Route 4 -0.105 1684 28-2% 178.81 6.3570 0.001158 10-0 0.012 1684 282h/2 39.60 6 (See 279'-111/2 11% 120 9.045 Notes) Flow (q) from Route 2 123-2% 14.031 2 -4-2 218.41 6.3570 0.001677 4E(17'-7), CV(40'-3), BV(12'-7) 403-2 0.676 2 -4-2 6 (See 6-9% 150 23.752 21'-7 Notes) 4 4-2 218.41 6.0900 0.001368 E(21'-7) 28- 41/2 0.039 , © M.E.P.CAD, Inc. Q AutoSPRINK 2020 v16.3.9.0 10/4/2022 8:23:09AM Page 6 Job Name: Remote Area Number: Date: 10/4/2022' Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _________________ Friction(Pf) 4 4-2 8 (See Notes) 356'-11% 150 23.791 2E(27'-2) 0.000367 -0.000 9 4-2 218.41 7.9800 411'-3Y2 0.151 9 4-2 8 (See Notes) 72 120 23.941 E(21'-1 %) 2111,4 0.000471 -3.107 10 3-0 218.41 8.2490 28'-3% 0.013 10 3-0 8 (See Notes) 14'-0 140 20.848 BFP, 2E(30'-6%) 61-1 0.000326 3.107 6 4-2 218.41 8.3900 75-1 0.025 6 4-2 8 (See Notes) 22'J1/2 150 23.979 E(27'-2), S 27-2 0.000367 0.000 1 -4'-2 218.41 7.9800 4991/2 0.018 250.00 23.997 Hose Allowance At Source Total(Pt) Route I 1 468.41 3229 9-0 5.6 19.51 1 (See Notes) 2811/2 120 12.133 Route ..... Sprinkler, 3E(2'-O), P0(5-U) 111-0 0.124253 -8.736 1341 29'-2 19.51 1.0490 39 11/2 4.861 1341 29'-2 21/2 3-2 120 8.258 0.001401 1375 29'-2 19.51 2.6350 3-2 0.004 1375 29'-2 20.10 21/2 (See Notes) 37'-9 120 8.263 Flow (q) from Route 8 T(16'-51/2), P0(16-5%) 32-11% 0.005191 0.415 1684 28-2% 39.60 2.6350 70-8% 0.367 9.045 Total(Pt) Route 2 3227 9-0 5.6 19.63 1 (See Notes) 25-10 120 12.282 ••"• Route 3..... Sprinkler, 3E(2'-O), P0(5-U) 111-0 0.125656 -8.525 1329 28'-8 19.63 1.0490 36-10 4.630 1329 28-8 21/2 2111/2 120 8.386 0.001416 1365 28-8 19.63 2.6350 0.004 1365 28'-8 20.12 21/2 2'-81/2 120 8.391 Flow (q) from Route 9 0.005227 1417 28-8 39.75 2.6350 2-8% 0.014 , © M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:09AM Page 7 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) __________ Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 1417 28-8 19.76 21/2 (See Notes) 10-0% 120 8.405 Flow (q) from Route 5 T(16'-51/4 16-5% 0.011027 1503 28-8 59.51 2.6350 26-6% 0.293 1503 28-8 2% (See Notes) U.111/2 120 8.697 P0(16-5%) 16-5% 0.004750 0.415 1504 2781/2 37.75 2.6350 17-5 0.083 9.195 Total(Pt) Route 3 3228 9,-U 5.6 19.63 1 (See Notes) 26'-4 120 12.293 "•• Route 4 ..... Sprinkler, 3E(2'-O), P0(5-0) 111-0 0.125769 -8.631 1347 28-11 19.63 1.0490 37'-4 4.694 1347 28-11 21/2 3-9 120 8.357 0.001418 1383 28-11 19.63 2.6350 3-9 0.005 1383 28-11 19.85 21/2 (See Notes) 37'O% 120 8.362 (q) from Route 7 T(16'-5%), P0(16-5%) 121 0.005163 0.415 Flow 1676 27-11% 39.49 2.6350 0.361 9.139 Total(Pt) Route 4 3325 9-0 5.6 19.76 1 (See Notes) 24'-2 120 12.454 Route 5 ..... Sprinkler, 3E(2'-O), P0(5-U) 111-0 0.127289 -8.525 1417 28'-8 19.76 1.0490 35'-2 4.476 8.405 Total(Pt) Route 5 3209 9-0 5.6 19.81 1 (See Notes) 24-7% 120 12.512 Route 6 ..... Sprinkler, 2E(2'-U), P0(5-C) 91-0 0.127839 -8.420 1319 28'-5 19.81 1.0490 33'-7% 4.297 8.390 Total(Pt) Route 6 3326 91-0 5.6 19.85 1 (See Notes) 23'-5% 120 12.568 Route 7 ..... Sprinkler, 3E(2'-O), P0(5-U) 111-0 0.128362 -8.631 1383 28-11 19.85 1.0490 34-5% 4.425 8.362 Total(Pt) Route 7 3327 9-0 5.6 20.10 1 (See Notes) 22-4% 120 12.877 "•• Route 8 ..... Sprinkler, 2E(2'-O), P0(5-U) 9-0 0.131284 -8.736 1375 29'-2 20.10 1.0490 31' 1/2 4.121 8.263 Total(Pt) Route 8 , © M.E.P.CAD, Inc. JAutoSPRlNK 2020 06.3.9.0 10/4/2022 8:23:09AM Page 8 Job Name: Remote Area Number: Date: 10/4/2022' Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings s & Device Equiv. Length (Foot) Length (Foot) __________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 3298 9-0 5.6 20.12 1 (See Notes) 21'-5 1 120 12.914 Route ..... Sprinkler, 2E(2'-o), P0(5-0) 9-0 1 0.131634 -8.525 1365 28'-8 20.12 1.0490 30-5 4.002 8.391 Total(Pt) Route 9 3297 9-0 5.6 20.14 1 (See Notes) 20-10 120 12.935 ••"• Route lO ..... Sprinkler, 2E(2'-O), P0(5-0) 9-0 0.131825 -8.420 1388 28'-5 20.14 1.0490 29-10 3.932 1388 28'-5 21/2 (See Notes) 2'-8 120 8.447 T(1 6-5V2) 16-5% 0.001486 1389 28'-5 20.14 2.6350 19-2 0.028 8.475 Total(Pt) Route 10 3342 91-0 5.6 20.36 1 (See Notes) 20-11 120 13.217 Route ll..... Sprinkler, 2E(2'-O), P0(5-0) 91 0 0.134487 -8.441 1446 2851/2 20.36 1.0490 29-11 4.023 1446 28-5% 21/2 (See Notes) 8-11 120 8.799 T(16-51/2), PO(16'-5%) 32111/2 0.001516 0.415 1502 27'-6 20.36 2.6350 41101/2 0.063 9.277 Total(Pt) Route 11 1673 2781/2 21.76 6 6-0 120 9.241 Route 12"... Flow (q) from Route 13 0.000024 -0.063 1674 27-10% 21.76 6.3570 6-0 0.000 9.178 Total(Pt) Route 12 1503 28'-8 21/2 (See Notes) 25-5% 120 8.697 Route 13 ..... T(1 6'-S%) T(16-51/2), P0(16-5%) 49-5 0.001715 0.415 1673 27-8% 21.76 2.6350 74-10% 0.128 9.241 Total(Pt) Route 13 f,© M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 8:23:09AM Page 9 Job Name: Remote Area Number: Date: 10/4/2022 I Equivalent Pipe Lengths of Valves and Fittings (C=120 only) IC Value Multiplier • Actual Inside Diameter 4.87 Factor Value Of C .100 130 140 150 ( \ = Schedule 40 Steel Pipe Inside Diameter J I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 221/20 Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. AutoSPRlNK 2020 06.3.9.0 10/4/2022 8:23:09AM Page 10 Hydraulic Calculations for Project Name: ABSORPTION SYSTEMS-PHASE 2 Location: 2820 LOKER AVE, CARLSBAD CA 92010 Drawing Name: Design Remote Area Number: 1 Calculation Date: 10/4/2022 Occupancy Classification Ordinary Group II (PRE-ACTION) Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 131ft2 (Actual 131ft2) 130ft2 Pendent 2 0 N/A gpm at Node: N/A 250.00 at Node: I Type Allowance at Source (Safety Margin = 86.313) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 302.15 @36.675 Type of System: PreAction Name of Contractor: TITAN FIRE PROTECTION Address: 1341 DISTRUBUTION DRIVE, VISTA CA 92081 Phone Number: Name of designer: NM Authority Having Jurisdiction: CITY OF CARLSBAD Notes Automatic peaking results Left: N/A Right: 36.675 M.E.P.CAD, Inc. AutoSPRlNK 2020 06.3.9.0 10/4/202211:09:52AM Page 1 Flow - gpm ,-© M.E.P.CAD, Inc. AutoSPRINK 2020 06.3.9.0 10/4/2022 11:09:54AM Page 2 Job Name: Remote Area Number: 150- 105 12C 13! 45 30 6C 15 9c 0 Water Supply Summary Sheet Node: I :Available Static 402.15 Pressure Supply 0 122.98 123.000 - 000.00 @ iiacoo 2.1536.675 30215 with Hose Allowance at Source System demand curve Z U 1111"tiI I 11 [[II El! I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I II I I I I i I I I I I I I I I I I I Q,,. 3100 6200 9300 12400 155 Hydraulic Graph N 1.85 Date: 10/4/2022 Isummary Of Outfiowing Devices I Job Number: 1 Report Description: Ordinary Group I Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Sprinkler 3725 26.15 26.00 5.6 21.801 . Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. MAutoSPRINK 2020 06.3.9.0 10/4/2022 11:09:54AM Page 3 Job Name: Remote Area Number: Date: 10/4/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 123.000 118.000 8000.00 122.988 302.15 36.675 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 4-2 Supply 36.675 52.15 3725 9-0 Sprinkler 21.801 26.15 3726 9-0 Sprinkler 21.556 26.00 5 4-2 36.658 7 4-2 36.661 9 4-2 36.674 12 4-2 36.671 13 3-0 33.565 1740 2841/2 22.529 1833 29-4 21.733 1846 9-6 24.004 1847 9-6 23.742 ,© M.E.P.CAD, Inc. MAutoSPRINK 2020 06.3.9.0 10/4/2022 11:09:56AM Paqe 4 Job Name: ,Remote Area Number: Date: 10/4/2022 Pipe Information Node I El (Fo v 1 e ot) K-Factor Flow added this step (q) Nominal ID Fitting & Device s s Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) __________ Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 3726 9-0 5.6 26.00 i (See Notes) 24 120 21.556 Route I ..... Sprinkler, 2E(2'-O), P0(5-0) 9-0 0.211435 -0.210 1847 9-6 26.00 1.0490 11-4 2.396 1847 9-6 11/2 9111/2 120 23.742 0.026249 1846 9'-6 26.00 1.6100 9-11 V2 0.261 1846 9-6 26.15 11,12 (See Notes) 362 120 24.004 Flow (q) from Route 2 4E(4'-O), DPV(-0.600), By, PO( 8-0) 24-0 0.095125 -8.595 1833 29-4 52.15 1.6100 60-2 6.325 1833 29'-4 21/2 (See Notes) 1111/2 120 21.733 T(16'-5%), P0(16-5%) 32111/2 0.008636 0.415 1740 28-4% 52.15 2.6350 44'-0% 0.381 1740 28-4% 6 (See Notes) 124-5 120 22.529 4E(17'-7), CV(40-3), BV(12'-7) 123-2% 0.000118 14.100 5 4-2 52.15 6.3570 247-8 0.029 5 -4-2 6 (See Notes) 691/2 150 36.658 E(21'-7) 0.003 21-7 0.000097 7 4-2 52.15 6.0900 28-4% 7 4-2 8 (See Notes) 3561111/2 150 36.661 2E(27-2) 0.000026 -0.000 12 -4'-2 52.15 7.9800 411-31/2 0.011 12 4-2 8 (See Notes) 7'2 120 36.671 E(21-1%) 21-1% 0.000033 -3.107 13 3-0 52.15 8.2490 28-3 % 0.001 13 3-0 8 (See Notes) 14'0 140 33.565 BFP, 2E(30'-61/2) 61-1 0.000023 3.107 9 4-2 52.15 8.3900 r75'-1 0.002 9 4-2 8 (1See Notes) 22'7% 150 36.674 E(27-2), S 27'-2 0.000026 0.000 1 4-2 52.15 7.9800 49-9 1/2 0.001 250.00 36.675 Hose Allowance At Source Total(Pt) Route 1 1 302.15 (,© M.E.P.CAD, Inc. AutoSPRlNK 2020 06.3.9.0 10/4/2022 11:09:58AM Page 5 Job Name: Remote Area Number: Date: 10/4/2022 Pipe Information El v1 Flow added Fittings & Length C Factor Total(Pt) Notes Node I e ot) (Fo K-Factor this step Nominal ID Devices (Foot) ___________ Fitting/Device (Equivalent (q) Equiv. Length) Fixed Pressure Losses, Fitting (Foot) Pf Friction Elev(Pe) Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to (Pt) and shown as 3725 9-0 5.6 26.15 1 (See I 231/2 120 21.801 Route ..... Notes) Sprinkler, 9-0 -0.210 1846 9-6 26.15 1.0490 I 0.213660 2E(2'-O), P0(5-0) 11'-3Y2 2.412 24.004 Total(Pt) Route 2 , © M.E.P.CAD, Inc. MAutoSPRINK 2020 06.3.9.0 10/4/2022 11:09:58AM Page 6 Job Name: Remote Area Number: Date: 10/4/2022 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) IC Value Multiplier • Actual Inside Diameter 4.87 ( \ =Factor Schedule 40 Steel Pipe Inside Diameter J Fittings Legend Value OfC 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve BalV Ball Valve C Cross Flow Turn 900 CV Check Valve E 900 Elbow Ee2 221/z0 Elbow FDC Fire Department Connection fig Flange g Gauge Ho Hose Hyd Hydrant Noz Nozzle PIV Post Indicating Valve PRV Pressure Reducing Valve sCV Swing Check Valve St Strainer U Union Z Cao AngV Angle Valve BFP Backfiow Preventer cplg Coupling DelV Deluge Valve EE 450 Elbow f Flow Device fE 90° FireLock(TM) Elbow FN Floating Node GloV Globe Valve Hose Hose LtE Long Turn Elbow P1 Pump In P0 Pipe Outlet red Reducer/Adapter SFx Seismic Flex T Tee Flow Turn 90° WirF Wirsbo b Bushing BV Butterfly Valve Cr Cross Run DPV Dry Pipe Valve Eel 111h° Elbow fd Flex Drop fEE 45° FireLock(TM) Elbow fT FireLock(TM) Tee GV Gate Valve HV Hose Valve mecT Mechanical Tee P2 Pump Out PrV Pressure Relief Valve S Supply Spr Sprinkler Tr Tee Run WMV Water Meter Valve ,© M.E.P.CAD, Inc. QAutoSPRINK 2020 06.3.9.0 10/4/2022 11:09:57AM Page 7 lit lit" - FIRE PROTECTION. Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS ABSORPTION SYSTEMS-PHASE 2 2820 LOKER AVE E, CARLSBAD CA 92010 Page 1 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Chart. LISTINGS AND APPROVALS c®us UL Listed: Category VNIV FM Approved: Classes 2017, 2015, 2043 Also approved for use in FM Approved vacuum dry sprinkler systems with a maximum supervisory vacuum pressure of -3 PSI (-207 mbar) ( ( CE: Standard EN12259-1, DOP_XT1A 0) LPCB Approved: reference no. 096m VdS Approved: Certificate no. G 422006 WARNING Cancer and Reproductive Harm- www.P65Wamings.ca.gov Refer to the Approval Chart and Design Criteria for requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 PSI (0.5 bar) Rated to: UL - 250 PSI (17 bar) WWP FM, CE, LPCB, and VdS - 175 PSI (12 bar) WWP Factory tested hydrostatically to 500 PSI (34.5 bar) Thread size: 1/2" NPT (15 mm BSPT) Nominal K-factor: 5.6 U.S. (80.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass CW602N, UNS-C84400 or QM Brass Deflector: Stainless Steel UNS S30400 Pip Cap Shell - Stainless Steel UNS-S44400 Pip Cap Disc - Stainless Steel UNS-530100 Belleville Spring - Nickel Alloy Pip Cap Seal - Polytetrafluoroethylene (PTFE) Compression Screw: Brass CW612N, CW508L, UNS-C36000 or UNS-C26000 Shipping Cap: Polyethylene Bulb: Glass, nominal 3 mm diameter Ordering Information: (Refer to Table I and the current Viking List Price Book.) INSTALLATION Refer to appropriate NFPA, FM Global, and/or any other applicable installation standards. JL•1IL Risk of permanent damage. Over-tightening the sprinkler can cause permanent damage. > Tighten the sprinkler to a MAXIMUM torque of 14 ft-lbs (19 N-m). OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Form No. F_110720 Rev 22.1 February 22, 2022 Replaces Form No. F 110720 21.3 (Added LPCB and VdS details) Page 3of7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com ' 1.. LE J the J.jrTh Sprinkler Size 1: Finishes the 2: Temperature Ratings Description Suffix, Nominal Rating Bulb Color Max. Ambient :: A b t Ceiling 3 Suffix Base Part NPT BSPT Number Inch mm Temperature 23870 1/2 Brass 135°F(57°C) Orange 100°F(38°C) A 23882 15 Chrome 155 °F (68 °C) Red 100 °F (38 °C) B White Polyester 4,6 M-IW 175°F (79 °C) Yellow 150°F (65 °C) D Black Polyester 4.6 M-/B 200 °F (93 °C) Green 150 °F (65 °C) E ENT 4.5,6 JN 286°F (141 °C) Blue 225°F (107 °C) G OPEN -- -- Z Example: 23870MB/W = VK3021 with white polyester finish and 155 °F (68 °C) nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): Standard Wrench: Part number 23559MB Recessed Socket Wrench: Part number 23560MB2 Sprinkler Cabinet: Up to 6 sprinklers: Part number 01724A 6-12 sprinklers: Part number 01725A Footnotes I. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Requires a 1/2" ratchet which is not available from Viking. Based on NFPA 13, NFPA 13R, and NFPA 130. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. UL Listed as corrosion resistant. FM Approved as corrosion resistant. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. UL Listed for 250 PSI (17 bar) WWP. ; A ae 0Top oView ) Figure 1: Sprinkler Wrenches Form No. F_110720 Rev 22.1 February 22, 2022 7116" (11 mm) Nominal Pipe Engagement I MR 1/2"NPT -LT 1 5mm BSPT 1-15/16" (49 mm) T Figure 2: Sprinkler Dimensions Page 4 of 7 'SJ l:II[.q..1•qM VK3021 QUICK RESPONSE I IQ :W :j PENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART Finish( es ) Viking Quick Response Pendent Sprinkler Temperature(s) j A1X KEY VK3021 K5.6 (80.6 metric) Escutcheon(s), If applicable Thread Size Listings and Approvals2 Sprinkler Base Part Number NPT BSPT cULus FM Inch mm Approval Specification Maximum WWP Approval Specification Maximum WWP 23870 1/2 -- Al, A2X, 133Y 250 PSI (17 bar) Al, B2X, B3Y 175 PSI (12 bar) 23882 -- 15 Al, A2X, 133Y 250 PSI (17 bar) Al, B2X, 133Y 175 PSI (12 bar) Additional Listings and Approvals Maximum WWP 175 PSI (12 bar) CE6 LPCBT VdS8 23870 1/2 -- Cl, D2X, D3Y Al, B2X, B3Y Al 23882 -- 15 Cl, D2X, D3Y Al, B2X, 133Y Al Approved Temperature Ratings A = 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C) and 286 OF (141 °C) B = 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 200 OF (93 °C) C = 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C) and 286 OF (141 °C) D = 155 OF (68 °C), 175 OF (79 °C), and 200 OF (93 °C) Approved Finishes I = Brass, Chrome, White Polyester 3,4, Black Polyester 3,4, and ENT4'5 2 = Brass, Chrome, White Polyester 3,4, and Black Polyester 3.4 3 = ENT4'5 X = Installed with Viking Recessed Escutcheons Models E-1, E-2, E-3, NP-I, NP-2, and NP-3, or Viking Standard Surface Mounted Escutcheons Y = Installed with Viking Recessed Escutcheons Models E-1 and NP-I, or Viking Standard Surface Mounted Escutcheons Footnotes 1 Base Part number is shown. For complete part number, refer to Viking's current price schedule. 2 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available upon request with the same Listings and Approvals as the standard colors. cULus Listed as corrosion resistant. FM Approved as corrosion resistant. 6 CE: Standard EN12259-1, Declaration of Performance DOP_XT1A. LPCB Approved; reference no. 096m 8 VdS Approved; Certificate no. G 422006 Form No. F_110720 Rev 22.1 February 22, 2022 Page 5of7 '4J II(IF11 VK3021 QUICK RESPONSE P ENDENT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA - UL cULus Listing Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is cULus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers shall be followed. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F .080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance With the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. DESIGN CRITERIA - FM FM AnrovaI Requirements: The Viking VK3021 Quick Response Pendent Sprinkler is FM Approved as quick response Non-Storage Pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from UL and/or NFPA criteria. IMPORTANT: Always refer to Form Number F_091699 - Care and Handling of Sprinklers. Also refer to Form Number F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_110720 Rev 22.1 February 22, 2022 Page 6 of 7 "J 11(1 lIG', VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. Install the escutcheon inner ring 2. Carefully slide the wrench** sideways onto the sprinkler threads. around the protective cap then push upwards to engage with the sprinkler wrench flats. 00 3. Install the sprinkler and escutcheon assembly into the pipe fitting. Be sure the escutcheon outer ring contacts the surface of the finished ceiling. Figure 3: Recessed Installation (with Recessed Socket Wrench) **A 1/2' ratchet is required (not available from Viking). 1. Install the escutcheon onto the 2. Carefully slide the wrench onto the 3. Install the sprinkler and escutcheon sprinkler threads. sprinkler wrench flats. assembly into the pipe fitting. Be sure the escutcheon contacts the surface of the finished ceiling. Figure 4: Installation (with Standard Wrench) Form No. F_110720 Rev 22.1 February 22, 2022 Ceiling opening size; Minimum: 2-5/16'159 mmI Maximum: 2-1/2' (64 6" rn) Page 7 of 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs©vlkingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Models E-I or NP-11 Recessed Escutcheon 2.1/8" (54 mm) Models E-2, E.3, NP-2 or NP-3 Thread. Recessed Coiling openingsize: 2-1/8" (84 mml. Escutcheon Minimum: 2-5/16" (59 mm) (E.3 and NP-3 Outer rings MaxImum: 2.1/2" (64 mm) have larger diameters) Max, 1-7/16' (37 mm) Mm. 13/16" (21 mm) Max. 1-3/4" (44 mm) -, Mm. 15/16" (24 mm) Standard Surface-Mounted Escutcheon 5: Installation Dimensions with Vi Form No. F 110720 Rev 22.1 February 22, 2022 Replaces Form No, F_I10720 21.3 AØ LPCS end V65 tail) Page 1 of 4 SJ I(J f%IG CA OF RE SPRINKLERSAND '- The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: Store sprinklers in a cool, dry place. Protect sprinklers during storage, transport, handling, and after installation. Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler operating elements. Protect sprinklers during handling and after installation, For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). SDrinklers with Protective Shields or Cans: DO NOT remove shields or caps until after sprinkler installation and there no longer Is potential for mechanical damage to the sprinkler operating elements, 'Sprinkler shields or caps MUST be removed BEFORE placing the system in service! Remove the sprinkler shield by carefully pulling it apart where it is snapped together. Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. DO NOT install sprinklers onto piping at the floor level. Install sprinklers after the piping is in place to prevent mechanical damage. DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. DO NOT attempt to remove drywall, paint, etc., from sprinklers. Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) (Original container used) (Placed loose ip bQx) (Protected with caps) tProtectiye aps not used) (Piping is in place at the (SpjlnkIert fi 9,9r level) ceiling) (Special installation (DesIgnated wrench not wrenches) used) ztWARNING: Cancer and Reproductive Harm- www.P65Wernin9s.ca.oy A WARNING Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should he destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid, Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance Instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Replaces Form No, F091699 Rev 16.1 (Added P65 Warning) Page 2 of 4 41KJF1cj CAg HANDLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vlklngcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handlln9 and Storgg: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap on shields and caps are factory Installed and are Intended to help protect the operating elements from mechanical damage during shipping, storage, and installation, NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MU ST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: The sprinkler has been installed*. The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST 'BE SPRI:RUgIRS 'PLACING THETM IN SERVI Figure 1: Sprinkler shield being removed from a pendent sprinkler. Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re- moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. To remove the cap, turn it slightly and pull It off the sprinkler. Refer to Figures 2 and 3. i.itt Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. I4ARN!NG1 Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are Included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No, F091699 18.10.11 Rev 16.1.P65 Concealed Sprinkler and Adapter Assembly (Protective Cap Removed) Concealed Sprinkler and Adapter Assembly with Protective Cap Cover Plate Assembly (Pendent Cover 12381 shown) Page 3 of 4 'N I KI W4i ;hhhh1ht CARE OF I1NG NKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs©vikingcorp.com àCAUflON j CONCEAL COVER ASMBUgS ARE FMGiLJ TO ASSAJILREAfl$FATQJY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARL GENERAL HANDLING AND STORAGE INSTRUCTIONS: Do not store in temperatures exceeding 100 'F (38 °C). Avoid direct sunlight and confined areas subject to heat. Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. -- Use original shipping containers. -- Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work Is being completed, Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. Do not over-tighten the sprinklers into fittings during Installation. Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. Do not attempt to remove drywall, paint, etc., from the sprinklers. Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MI BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICEI Refer to the appropriate current technical data pages for complete care, handling, and installation Instructions. Data pages are Included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. viklnggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Page 4 of 4 \HKIFtIG CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking's sprinklers are available with factory-applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers; Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) Store containers of wax-coated sprinklers separate from other sprinklers, Protect the sprinklers during storage, transport, handling, and after Installation. Use original shipping containers. Do not place sprinklers In loose boxes, bins, or buckets. Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). Take care not to crack the wax coating on the units. For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating, Thereafter, inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Spnnkl& Temperafure Rating (Fusing Point) Wax Part Number TABLE 1 Wax Melting e Point ' aximum Ambient Ceiling TTemperature'Wax Color 155 °F (68 °C) / 165 °F (74 °C) 02568A 148 °F (64 °C) 100 °F (38 °C) Light Brown 175 °F (79 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 200 °F (93 °C) 04146A 161 ¶ (71 °C) 150 °F (65 °C) Brown 220 °F (104 °C) 02569A 170 °F (76 °C) 150 °F (65 °C) Dark Brown 286 °F(141°C) 02569A 170°F(76°C) 150F(65°C) Dark Brown Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction, Refer to specific installation standards. [ARNINGf Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vlklnggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Replaces Form No. F091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 N11Q11G 'JM4 SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern, A closed or sealed sprinkler refers to a complete assembly, including the therrnosonsitivo operating element, An open sprinkler does not use an operating element and is open at all times. The distribution of water is intended to extinguish a fire or to control its spread. Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected. 2. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or WARNING: Cancer and Reproductive He approval agency listings. ww.P65Warnings.agov TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)], Sprinkler Identification: Viking sprinklers are identified and marked with the word Viking the sprinkler identification number (SIN) consisting of "VK" plus a three digit number*, the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion-resistant coatings or are fabricated from non-corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification. Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum-reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion, depending upon sprinkler location, occupancy classification, commodity classification, storage height, and other hazards. In all cases, the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors. The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-23. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER: A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella-shaped spray pat- tern downward. Marked "SSU" (Standard Sprinkler Upright) or "UPRIGHT" on the deflector, Viking Technical Data may be found on PENDENT SPRINKLER: A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at tor below the frame so water flows downward through the orifice, striking http:llwww.viklnggroupinc.com, the deflector and forming an umbrella-shaped spray pattern downward. The Web site may include a more recent Marked "SSP' (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER: An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent position, The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers, DO NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P" (Conventional Upright/Pendant) on the deflector, Form No, F,080814 18,12.06 Rev 14.1.P65 Replaces Form No, F 080814 Rev 14,1 (Added P85 Warning.) Page 2 of 3 TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com VERTlLSIDWALL$WRlNKLER; A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked "SIDEWALL" on the deflector with an arrow and the word "FLOW". (Note; Some vertical sidewall sprinklers can only be installed in the upright or pendent position—in this case, the sprinkler will also be marked UPRIGHT" or "PENDENT".) HQBIZQUT A sprinkler intended for installation near the wall and ceiling. The special deflector provides a water spray pattern outward in a quarter-spherical pattern, Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler. The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL" and "TOP" with an arrow and the word "FLOW'. A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listings Maximum area of coverage minimum flow rate, orifice size and nominal K Factor are specified in the individual listings. EC sprinklers are intended for Light-Hazard occupancies with smooth, flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard, Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED COVERAGEREC) PRINKLER A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response QREC sprinklers are only intended for Light Hazard occupancies The sprinkler is marked OREC FLUSH SPRINKLER A decorative spray sprinkler intended for installation with a concealed piping system The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP'. CONCEALED SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall, During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and TOP". RECESSD SPRINKLER; A spray sprinkler assembly intended for installation with a concealed piping system. The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON, CORROSION-RESISTANT SPRINKLER: A special service sprinkler with non-corrosive protective coatings, or that is fabricated from non-corrosive material, for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER: A special-service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklers are marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the ceiling or wall], LARGE DROP SPRINKLER; A type of special application sprinkler used to provide fire control of specific high-challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella-shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra-large orifice with a nominal K-Factor of 11.2. Marked "HIGH CHALLENGE" and "UPRIGHT". E61-Y SJPPRESSION FAST-RESPONSE (EER) SPRINKLER: A sprinkler intended to provide fire suppression of specific high- challenge fire hazards through the use of a fast response fusible link, 14.0, 168, or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high-momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Marked "ESFR" and "UPRIGHT" or "PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER; A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly, Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER; A sprinkler intended for use in the following occupancies; one- and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13, Form No, F080814 18.12.06 Rev 14.1,P65 Page 3 of S TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Residential sprinklers have a unique distribution pattern and utilize a "fast response" heat sensitive operating element, They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes. For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction. In addition to standard markings, the unit is identified as "RESIDENTIAL SPRINKLER" or "RES", INSTALLATION Refer to appropriate NFPA Installation Standards, OPERATION Refer to the appropriate sprinkler technical data page(s). INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT: Always referto Bulletin Form No. F_091699 -Care and Handling of Sprinklers and the appropriate sprin- klergeneral care, installation, and maintenance guide.Viking sprinklers areto be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and alsowiththe provisions of governmental codes, ordinances, and standards,wheneverapplicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No, F080814 18,12.06 Rev 14.1.P65 Replaces Form No, F 080814 Rev 141 (Added P65 Warning.) Page 1 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking wobsite for the latest edition of this technical data page. DESCRIPTION - STANDARD RESPONSE, QUICK RESPONSE, EXTENDED COVERAGE, AND DRY SPRINKLERS Viking thermosensitive spray sprinklers consist of a small frame and either a glass bulb or a fusible operating element, Available styles Include pendent, flush pendent, concealed pendent, upright, horizontal sidewall, vertical sidewall, or conventional, depending on the particular sprinkler model selected. Viking sprinklers are available with various finishes, temperature ratings, responses, and K-Factors to meet design requirementst. Used in conjunction with one of the corrosion-resistant coatings (for frame style sprinklers), the units provide protection against many corrosive environments In addition, the special Polyester or PTFE coatings can be used in decorative applications where colors are desired. t Refer to the sprinkler technical data page for available styles, finishes, temperature ratings, responses, and nominal K-Factors for specific sprinkler models, LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or approval agency listings. TECHNICAL DATA Specifications: WARNING: Cancer and Reproductive Harm- Refer to the appropriate sprinkler technical data sheet. wwwP65Warnings.cagov Material Standards: Refer to the appropriate sprinkler technical data sheet. INSTALLATION NOTE: Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT: 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) Care and Handling (also refer to Bulletin - Care and Handling of Sprinklers, Form No. F_091699.) Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature al- lowed (refer to the temperature chart on the sprinkler technical data page). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed immediately. (Note: Installing glass bulb sprinklers in direct sunlight (ultraviolet light) may affect the color of the dye used to color code the bulb. This color change does not affect the integrity of the bulb.) Sprinklers must be protected from mechanical damage during storage, transport, handling, and after installation. Sprinklers subject to mechanical damage must be protected with an approved sprinkler guard. Use only sprinklers listed as corrosion resistant when subject to corrosive environments. When installing corrosion-resistant sprin- klers, take care not to damage the corrosion-resistant coating. Use only the special wrench designed for installing coated or recessed Viking sprinklers (any other wrench may damage the unit). Concealed sprinklers must be installed in neutral or negative pressure plenums onlyl Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers whore they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. Wet pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to freezing must be listed dry sprinklers, upright, or horizontal sidewall sprinklers installed so that water is not trapped. For dry systems, pendent sprinklers and sidewall sprinklers installed on return bonds are permitted, where the sprinklers, return bend, and branch line piping are In an area maintained at or above 40 °F (4 °C). Installation Instructions - Standard Spray Sprinklers Viking sprinklers are manufactured and tested to meet the rigid requirements of approving agencies. They are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to sprinklers or cover plate assemblies after they leave the factory including, but not limited to: painting, plating, coating, or modification, may render them Inoperative and will automatically nullify the approvals and any guarantee made by The Viking Corporation, Form No. F080614 18.10.11 Rev 16.1.P65 Replaces Form No, F 080614 Rev 16.1 (Added P65 Warning.) Page 2 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384.5464 Fax: 269-818.1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Before installation, be sure to have the appropriate sprinkler model and style, with the correct K-Factor, temperature rating, and response characteristics, Sprinklers must be Installed after the piping is in place to prevent mechanical damage. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled, Ia. For frame-style sprinklers, install escutcheon (if used), which is designed to thread onto the external threads of the sprinkler. Refer to the appropriate sprinkler data page to determine approved escutcheons for use with specific sprinkler models. lb. For flush and concealed style sprinklers: Cut the sprinkler nipple so that the W or 3/4" (15 mm or 20 mm)* NPT outlet of the reducing coupling is at the desired location, and centered in the opening* in the ceiling or wall. depends on the sprinkler model used. Refer to the sprinkler technical data page. Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet, NOTE: Sprinklers with protective caps or bulb shields must have the caps or shields kept on them when applying pipe-joint compound or tape. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily.. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. DO NOT use the deflector or fusible element to start or thread the sprinkler into a fitting. Install the sprinkler onto the piping using the special sprinkler wrench only, taking care not to over-tighten or damage the sprinkler. For flush and concealed style sprinklers; the internal diameter of the special sprinkler installation wrench is designed for use with the sprinkler contained in the protective cap. Exception: For domed concealed sprinklers, remove the protective cap for installation, and then place it back on the sprinkler temporarily. Thread the flush or concealed sprinkler into the W' or 3/4" (15 mm or 20 mm)* NPT outlet of the coupling by turning it clockwise with the special sprinkler wrench. "Thread size depends on the particular sprinkler model used. Refer to the sprinkler technical data page. C. Installation Instructions - Dry Sprinklers WARNING: Viking dry sprinklers are to be installed in the 1" outlet (for dry and preaction systems), or run of malleable, ductile iron, or Nibco CPVC* threaded tee fittings (for wet systems) that meet the dimensional requirements of ANSI B16.3 (Class 150), or cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125), even at branch line ends. The threaded end of the dry sprinkler is designed to allow the seal to penetrate and extend into the fitting to a predetermined depth. This prevents condensation from accumulating and freezing over the sprinkler seal. *NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl. When selecting other CPVC fittings, contact Viking Technical Services. DO NOT install the dry sprinkler into a threaded elbow, coupling, or any other fitting that could interfere with thread penetration. Such installation would damage the brass seal. DO NOT install dry sprinklers into couplings or fittings that would allow condensation to accumulate above the seal when the sprinkler is located in an area subject to freezing. NEVER try to modify dry sprinklers. They are manufactured for specific 'A" or "B" dimensions and cannot be modified. The dry sprinkler must be installed after the piping is in place to prevent mechanical damage. Before installation, be sure to have the correct sprinkler model and style, with the appropriate "A" or "B" dimension(s), temperature rating, orifice size, and response characteristics. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. Exception: For concealed and adjustable recessed dry sprinklers, the protective caps and shields are removed for installation. To Install the dry sprinkler, refer to the instructions below and the appropriate sprinkler technical data page for illustrated instruc- tions. Dry upright sprinklers must be installed above the piping, in the upright position only. When installing dry upright or plain barrel style vertical sidewall sprinklers on piping located close to the ceiling, it may he necessary to lower the sprinkler into the fitting from above the ceiling. When installing dry upright or plain barrel vertical sidewall sprinklers from below the ceiling, verify that the opening in the ceiling is a minimum 1-1/2" (38.1 mm) in diameter. For dry upright or plain barrel vertical sidewall sprinklers in the upright position: First, install the escutcheon (if used) over the threaded end of the sprinkler barrel. Slide the escutcheon past the external threads. NOTE: When installing the dry upright or plain barrel vertical sidewall sprinkler from above the ceiling, It will be necessary to install the escutcheon after lowering the threaded end of the sprinkler through the ceiling penetration, A. For all dry sprinklers: Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler barrel only, taking care not to allow a build-up of compound or tape over the brass inlet and seal. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Form No, F080614 18.10.11 Rev 16.1,P65 Page 3 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email; techsvcs©viklngcorp.com Visit the Viking website for the latest edition of this technical data page. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Install the dry sprinkler on the piping using the special dry sprinkler wrench only, while taking care not to damage the sprinkler. NOTE; Thread the sprinkler into the fitting hand tight, plus 1/2 turn with the dry sprinkler wrench. For adjustable standard and adjustable recessed dry pendent and sidewall sprinklers: escutcheons can be installed after the sprinklers have been installed onto the piping. Refer to the appropriate sprinkler technical data page for escutcheon Installation instructions and Illustrations, D. Installation Instructions - Testing 4, After Installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation stand- ards. Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi (20,7 bar) for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. a, Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the sprinkler must be removed, new pipe-joint compound or tape applied, and then reinstalled, This Is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Air testing (do not exceed 40 psi (2.76 bar)] the sprinkler piping prior to testing with water may be considered in areas where leakage during testing must be prevented. Refer to the Installation Standards and the Authority Having Jurisdiction. b. Remove plastic protective sprinkler caps or bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating ele- ments. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS OR BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICEI Retain a protective cap or shield in the spare sprinkler cabinet. For flush style sprinklers: the ceiling ring can now be installed onto the sprinkler body. Align the ceiling ring with the sprinkler body and thread or push it on (depends on sprinkler model) until the outer flange touches the surface of the ceiling. Note the maximum adjustment is 1/4" (6.35 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple as required. For concealed sprinklers: the cover assembly can now be attached. Remove the cover from the protective box, taking care not to damage the cover plate assembly. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling. Push the cover plate assembly onto the sprinkler until the unfinished brass flange of the cover plate base (or the cover adapter, if used) touches the surface of the ceiling. Refer to the applicable technical data sheet to determin the maximum adjustment available for concealed sprinklers. DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler drop nipple. NOTE: If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See section 6. INSPECTIONS, TESTS AND MAINTENANCE and follow all warnings and instructions. 5. OPERATION Refer to the appropriate sprinkler technical data page(s). During fire conditions, the operating element fuses or shatters (depending on the type of sprinkler), releasing the pip cap and sealing assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. IMPORTANT: Always refer to Bulletin Form No. F091699 Care and Handling of Sprinklers. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appro- priate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No, F080614 18.10.11 Rev 16.1.P65 Page 4 of 4 IKJ INSTALLATION, AND '.1 II6 SPRINKLER GENERAL CARE, MAINTENANCE GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs©viklngcorp.com Visit the Viking website for the latest edition of this technical data page. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: Refer to NFPA 25 for Inspection, Testing and Maintenance requirements, NOTICE: The owner is responsible for having the fire-protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and Inspection requirements that must be followed. A. Sprinklers must be Inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. Frequency of inspec- tions may vary due to corrosive atmospheres, water supplies, and activity around the sprinkler unit. B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced im- mediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required, installation standards require sprinklers to be tested and, If necessary, replaced after a specified term of service. Refer to NFPA 25 and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be reassembled or re-used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies with identical performance char- acteristics. C. The sprinkler discharge pattern Is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern, All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve Instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. For frame-style sprinklers, use the special sprinkler wrench to remove the old sprinkler by turning it counterclockwise to unthread it from the piping. For flush and concealed style sprinklers: Remove the ceiling ring or cover plate assem- bly before unthreading the sprinkler body from the piping. Ceiling rings and cover plates can be removed ei- ther by gently unthreading them or pulling them off the sprinkler body (depends on the sprinkler model used). After the ceiling ring or cover plate assembly has been removed from the sprinkler body, place the plastic protective cap (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler wrench over the cap. Then use the wrench to unthread the sprinkler from the piping. Exception: Domed concealed sprinklers are removed without the plastic cap. 3. Install the new sprinkler unit by following the instructions in section 4. INSTALLATION. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct K-Factor, temperature rating, and response character- istics. A fully stocked spare sprinkler cabinet should be provided for this purpose. For flush or concealed sprinklers: stock of spare ceiling rings or cover plates should also be available in the spare sprinkler cabinet, E. Place the system back in service and secure all valves. Check for and repair all leaks. Sprinkler systems that have been sub- jected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements, 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation, 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No, F080614 18.10,11 Rev 16.1.P65 Replaces Form No, F 080614 Rev 16.1 (Added P65 Warning.) Page 1 of 1 Ki NG REGULATORY AND HEALTH :UJU*II WARNINGS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. AWARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to lead nickel, butadiene titaninum dioxide chromium carbon black and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No, F111218 18.11.15 Rev 18.1 New Bulletin Page 1 of 1 XTI Sprinkler and N41KJW4j XG Guard Assemblies The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com INTRODUCTION The purpose of this bulletin is to inform users of proper XG Guard usage for the Model XTI Sprinklers. The XG Guard assemblies are specifically listed and approved for use on Model XT1 Sprinklers; no other guard assemblies should be used. I A WARNING I Viking sprinklers are manufactured and tested to meet the rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: unlisted accessories, painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. Refer to the Authority Having Jurisdiction prior to installation. GENERAL INFORMATION: A potential product performance issue may exist when listed products are combined with unlisted product(s) that have not been evaluated together by a recognized approval laboratory. With the development of new products and existing products, it is extremely important to correctly match a sprinkler with a sprinkler guard. Please refer to the appropriate manufacturer's technical literature or call Viking Technical Services at 877-384-5464. IMPORTANT ._ Model XTI sprinklers are specifically listed and approved with XG Guard. The XG Guard, part number 22931, is listed and approved for use with the following XTI sprinklers: VKIOOI, VK1021, VK3001, VK3021, VK2002, VK2022, VK3502, VK3522, VK2001, VK2021, VK3501, VK3521. NOTE: Image is represetative only. Actual product appearance may vary. Listed and Approved XG GuardlXli Sprinkler Assembly Unlisted GuardIXT1 Sprinkler Assembly A Activation - element T-hinge - blocked Form No. F_091119 19.09.11 Rev 19.1 Page 1 of 9 STANDARD AND QUICK RESPONSE 'sJ II(II1Ei® CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Standard and Quick Response Concealed Pendent Sprinkler VK4621 is a small thermosensitive, glass-bulb sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The low-profile cover assemblies provide up to %" (13 mm) of vertical adjustment. Features: K5.6 (80.6 metric). Quick response glass bulb operating element. Integral threaded adapter cup accepts push-on or thread-on cover plates. Low-profile, small diameter, removeable cover plates offer almost flush appearance upon installation and allow ease of maintenance. Protective cap prevents damage during installation and finishing and keeps errant overspray from coating internal parts. Various finishes available to meet design requirements. Optional Electroless Nickel PTFE (ENT) coating provides corrosion resistance (see Approval Chart). 2. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2015 Also approved for use in FM Approved vacuum dry sprinkler systems with a maximum supervisory vacuum pressure of -3 psi (-207mbar) zt WARNING: Cancer and Reproductive Harm. www.P65WarnIngs.ca.gov Refer to the Approval Charts and Design Criteria on for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: FM - 175 psi (12 bar). UL - 250 psi (17.2 bar) Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" NPT or BSPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler body: QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-543000 Pip Cap and Insert Assembly: Copper UNS-C11000, SS UNS-S30400 and SS UNS-S31600 Compression Screw: UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel JIS G3141 and Carbon Steel UNS-G10100 (per JIS G3141) Shipping Cap: High Density Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-530400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: Refer to Tables I and 2. INSTALLATION Refer to appropriate NFPA Installation Standards and installation instructions in this document. Form No. F_092121 21.11.22 Rev 21.2 New form. Page 2 of 9 STANDARD AND .J I F1 F1G l:II[.u.7M QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE Instructions: Select a Sprinkler Base Part Number Add the suffix for the desired Finish Add the suffix for the desired Sprinkler Temperature Rating Order a cover plate (refer to Table 2) Example: 24682AE = 200 OF (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Size 1: Finishes 2: Temperature Ratings Base Part No. NPT BSPT Description Suffix' Sprinkler Temperature Nominal Bulb Max.Ambient Suffix Classification Rating Color Ceiling Temperature 24682 1 1/2" Brass A Ordinary 155°F(68°C) Red 100°F(38°C) B 22962 -- _1/2" ENT 3.4,6 JN Intermediate 175°F(79°C) Yellow 150°F(65°C) D Intermediate 200°F(93°C) Green 150°F(65°C) E Accessories Sprinkler Wrenches and Tools (see Figure 1): Installation wrench: 24339 Protective cap removal tool: 24340 Concealed Cover Plate Installer Tool Part Number: 14412 7 (available since 2007) Large Concealed Cover Plate Installer Tool Part No. 14867 7 (available since 2007) Sprinkler Cabinet: Part number 01731A. Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Based on NFPA 13, NFPA 13R, and NFPA 131). Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. UL Listed as corrosion resistant. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do rot represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. Require a 1/2" ratchet which is not available from us. FM Approved as a decorative finish. i. The installer tool is for push-on style cover plates only. Form No. F092121 21.11.22 Rev 21.2 Page 3 of 9 STANDARD AND 'sJ II(IIt1G 1 A A QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: Select a Cover Plate Base Part Number Add the suffix for the desired Finish Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC1W = 165 °F (74 °C) Temperature Rated 2-3/4" (70 mm) diameter Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a Finish ITThread-On ]I1Style Push-On IStyle Base Part Size Base Part Size Number Inch (mm) Type Number Inch (mm) Type Description Suffix, 23190 2-3/4(70) Round 23447 2-3/4(70) Round Polished Chrome F 23174 3-5/16(84) Round 23463 3-5/16 (84) Round Brushed Chrome F-/B 23179 1 3-5/16(84) Square 23482 3-5/16(84) Square Bright Brass B 23193k 2-3/4 (70) Stainless 23455 2-3/4 (70) Stainless Antique Brass B-/A Brushed Brass B-/B Steel Round Steel Round 231834 3-5/16(84) Stainless 23473 3-5/16 (84) Stainless Brushed Copper E-/B Painted White M-/W Steel Round Steel Round 231744CR 1 3-5/16 (84) Clean Room 234634CR 3-5/16(84) Clean Room Painted Ivory M-/I Stainless Stainless Painted Black M-/B 231834CR 3-5/16(84) Steel Round 23473-/CR 3-5/16(84) Steel Round Clean Room Clean Room 3: Temperature Rating Matrix' 2 Cover Plate Nominal Temperature Sprinkler Nominal Rating Sprinkler Maximum Ambient Suffix Rating (Required) Classification Ceiling Temperature UL: 135 °F (57 °C) FM: 139° F (59 °C) Ordinary 155 °F (68 °C) 100 °F (38 °C) A 165 °F (74 °C) Intermediate 175 °F (79 °C) 150 °F (65 °C) C 165 °F (74 °C) Intermediate 200 °F (93 °C) 150 °F (65 °C) C Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Stainless Steel versions are not available with any finishes or paint. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. Form No. F092121 21.11.22 Rev 21.2 Page 4 of 9 NjjQWg STANDARD AND QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Cha rt I 1-SprinklerTemperatureRang 4, i— Cover Plate Temperature Rang Concealed Pendent Sprinkler VK4621 Cover Plate Finish KEY Sprinkler Thread Size Nominal K-factor Maximum Listings and Approvals' Base Part SIN Water Working Pressure (Refer also to Design Criteria) No.' NPT BSPT U.S. metric' cULus FM cULus4 FM Standard Response Applications 24682A VK4621 1/2' -- 5.6 80.6 -- 175 psi (12 bar) -- AV1, BX1, AS2, BT2 24682JN78 VK4621 1/2' -- 5.6 80.6 -- 175 psi (12 bar) -- AV1, BX1, AS2, BT2 22962A VK4621 -- 1/2" 5.6 80.6 -- 175 psi (12 bar) -- AV1, BX1, AS2, BT2 22962JN7'8 VK4621 -- 1/2" 56 80.6 - 175 psi (12 bar) -- AV1, BX1,AS2, BT2 Quick Response Applications 24682A VK4621 1/2" -- 5.6 80.6 250 psi (17.2 bar) -- AV1, BX1, AS2, BT2, AY3, BZ3 -- 24682JN78 VK4621 1/2" -- 5.6 80.6 250 psi (17.2 bar) -- AV1, BX1, AS2, BT2, AY3, BZ3 -- 22962A VK4621 -- 1/2" 56 80.6 250 psi (17.2 bar) -- AV1, BX1, AS2, BT2, AY3, BZ3 -- 22962JN78 VK4621 -- 1/2" 56 80.6 250 psi (17.2 bar) -- AV1, BX1, AS2, BT2, AY3, BZ3 -- Sprinkler Temperature Ratings Cover Plate Assembly Temperature Ratings' Cover Plate Assembly Finishes S - 135 °F (57 °C) cULus Listed or 139 °F (59 °C) FM Approved Stainless Steel 1 - Polished Chrome, cover 23193 and 23455, or 23183 and 23473 (large diameter) Brushed Chrome, T - 165 °F (74 °C) Stainless Steel cover 23193 and 23455 or 23183 and 23473 Bright Brass, Antique (large diameter) Brass, Brushed Brass, V - 135 °F (57 °C) cULus Listed or 139 °F (59 °C) FM Approved cover 23190 Brushed Copper, A= 155°F (68 'C) and 23447, 23174 and 23463 (large diameter), or 23179 and 23482 (square Painted' White, B = 175°F (79 °C) and 200 'F (93 'C) cover plate) Painted' Ivory, or X - 165 °F (74 °C) cover 23190 and 23447, or 23174 and 23463 (large diameter) Painted' Black Y - 135 °F (57 'C) Clean Room Cover 23174A-/CR and 23463A-/CR or Stainless Steel 135 'F (57 'C) Stainless Steel Clean Room Cover 23183A1CR and Polished Chrome, 23473NCR Painted White, Painted Z - 165 °F (74 'C) Clean Room Cover 23174C-/CR and 23463C-/CR Ivory, or Painted Black Footnotes I. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. The 135 'F (57 'C) [139 °F (59 'C)] covers have an orange label. The 165 'F (74 'C) covers have a white label. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. cULus Listed as corrosion resistant. FM Approved as a decorative finish. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 2. Form No. F092121 21.11.22 Rev 21.2 Page 5 of 9 STANDARD AND QUICK RESPONSE N41K]I1I CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA -UL (Also refer to Approval Chart) cULus Listing Requirements: Concealed Pendent Sprinkler VK4621 is cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. DESIGN CRITERIA -FM (Also refer to Approval Chart) FM Aooroval Requirements: Viking Concealed Pendent Sprinkler VK4621 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. --- Form No. F092121 21.11.22 Rev 21.2 Page 6 of 9 STANDARD AND QUICK RESPONSE l:iIE•.7M CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com AB Installation Wrench Cap Removal Tool Figure 1: Sprinkler Wrench and Cap Removal Tool CUSl-04\ : j; All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 2: Identification of Custom Paint -.4 -4 3-5/16" (84 mm) Figure 3: Square Cover Assembly Form No. F092121 21.11.22 Rev 21.2 Page 7of9 STANDARD AND QUICK RESPONSE 41KJNG4N Im CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com WNPT orBSPT ;1 3 (76 mm) = a- (13 mm) If the bottom of the cover is flush with the surface of the ceiling when installed, the sprinkler adapter cup will be recessed 1/2" (15 mm). See Figure 5. Figure 4: Sprinkler Dimensions Minimum required opening in the ceiling 2'/" Nominal pipe engagement 1/'6"(11 mm) igagement - - im) 21/2 Ii (64 mm) Maximum - ----- Minimum required opening in the ceiling 2'/4" - (57 mm) Install the sprinkler so the finished surface of the ceiling lines up within the marked 1/2' (13 mm) range on the protective cap (A). Figure 5: Sprinkler Installation Dimensions Form No. F092121 21.11.22 Rev 21.2 C B Page 8 of 9 ' STANDARD AND 'I II(IF1G® QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com A USE ONLY the designated sprinkler wrenches shown in this document. Permanent damage to the sprinkler assembly can occur if the proper wrench is not used. Other sprinkler wrenches available from Viking may fit into the sprinkler adapter cup; however, only the wrenches shown here are designed to properly install this sprinkler. Step 1: Insert the wrench (A) into the slots (B) on the protective cap (C). Fil Step 2: Rotate the wrench slightly in either direction until the tines on the wrench (D) line up with the vent openings (E) on the adapter cup and lock into place. NOTE: A leak tight seal must be achieved. Turn the sprinkler clockwise I to 1-½ turns past finger-tight. Figure 6: Using the Sprinkler Wrench Step 1: Attach a piece of CPVC pipe as shown and tighten the thumb screw. (not shown); then, insert the tool (A) into the slots (B) in the protective cap (C). Form No. F092121 21.11.22 Rev 21.2 Step 2: Rotate the tool slightly to lock into place. Figure 7: Using the Cap Removal Tool Step 2: Gently, pull downward to remove the protective cap. The deflector will slide downwards on the pins. Page 9 of 9 STANDARD AND QUICK RESPONSE N II(IFrIG CONCEALED PENDENT 7 SPRINKLER VK4621 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Minimum Maximum Install the cover plate by inserting the adpater into the adapter cup and pushing or threading into place (depending on style). Snug the cover plate in place by rotating clockwise. Ensure the cover plate is flush with the ceiling as shown to allow airflow through the sprinkler assembly. Figure 8: Installing the Cover Plate Form No. F_092121 21.11.22 Rev 21.2 New Form. Page 1 of 4 1 CARE AND HANDLING 41KIW4j F SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcs©vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: Store sprinklers in a cool, dry place. Protect sprinklers during storage, transport, handling, and after installation, Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. Keep sprinklers separated at all times, DO NOT allow metal parts to contact sprinkler operating elements. Protect sprinklers during handling and after installation. For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). Sorinklers with Protective Shields or Caos: DO NOT remove shields or caps until after sprinkler Installation and there no longer Is potential for mechanical damage to the sprinkler operating elements. Sprinkler shields or caps MUST be removed BEFORE placing the system in service! Remove the sprinkler shield by carefully pulling it apart where it Is snapped together. Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. DO NOT install sprinklers onto piping at the floor level. Install sprinklers after the piping is in place to prevent mechanical damage. DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. DO NOT attempt to remove drywall, paint, etc., from sprinklers. Take care not to over-tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) 3/4" NPT 20 ft-lbs. (27.1 N-m) 1" NPT: 30 ft-lbs. (40.7 N-m) (Original container used) (Placed lqse in pox) (Protected with caps) (Protective caps not used) (Piping is In place at the (Spun icier at floor level) ceiling) (Special Installation (Designated wrench fiot wrenches) used) WARNING: Cancer and Reproductive Harm. wawP65Warnin9s.ca.9ov A WARNING Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should he destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must he replaced per NFPA 13. Protect sprinklers from paint and paint overspray In accordance with the installation standards, Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance Instructions, For additional product and system information Viking data pages and installation Instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 2 of 4 4I I K1I1G :iuiuuii CAOF tIJ!NG The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap. on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation, NOTE: It Is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: The sprinkler has been installed*, The wall or ceiling finish work is completed whore the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. ~11JELDS AND 0, P§ MU!$,T ;BE REMOVED Fa &CIING THE j5-aTEM IN :SERVKE Figure 1: Sprinkler shield being removed from a pendent sprinkler. Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re- moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove thorn! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1, To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. L.iti Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used, i AWARlNGj Never Install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and Installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vlkinggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.1265 Concealed Sprinkler and Adapter Assembly (Protective Cap Removed) Concealed Sprinkler and Adapter Assembly with Protective Cap Cover Plate Assembly (Pendent Cover 12381 shown) Page 3 of 4 N I KJ W4i CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877.384-5464 Fax: 269.818-1680 Email: techsvcs©vlklngcorp.com LCAUTJ CQNCALD COVER AM ARE FMGJL TO A. 3ATL15FATQRY PERFORMAN 0J THE PR0DV)T, HANDLE WITH CARE GENERAL HANDLING AND STORAGE INSTRUCTIONS: Do not store in temperatures exceeding 100 °F (38 °C). Avoid direct sunlight and confined areas subject to heat, Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. -- Use original shipping containers. -- Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed, Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers; NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. Do not over-tighten the sprinklers into fittings during installation. Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. Do not attempt to remove drywall, paint, etc., from the sprinklers. Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MQ.I BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F091699 18.10.11 Rev 16.1.P65 Page 4 of 4 'J I KI N6i CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking's sprinklers are available with factory-applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers; Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table I below.) Store containers of wax-coated sprinklers separate from other sprinklers. Protect the sprinklers during storage, transport, handling, and after installation. Use original shipping containers. Do not place sprinklers In loose boxes, bins, or buckets, Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). Take care not to crack the wax coating on the units. For touching up the wax coating after installation, wax is available from Viking in bar form, Refer to Table I below, The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. Use care when locating sprinklers near fixtures that can generate heat, Do not Install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. Inspect the coated sprinklers frequently soon after Installation to verify the integrity of the corrosion resistant coating. Thereafter, Inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Sprinkler Temperature Rating (Fusing Point) Wax Part Number TABLE 1 Wax MeltingPoint Maximum Abient m Ceiling Temperature' Wax Color 155 OF (68 °C) / 165 OF (74 °C) 02568A 148 OF (64 00) 100 OF (38 °C) Light Brown 175 °F (79 00) 04146A 161 OF (71 °C) 150 OF (65 0C) Brown 200 OF (93 °C) 04146A 161 OF (71 °C) 150 OF (65 °C) Brown 220°F(104°C) 02569A 170°F(76°C) 150°F(65°C) Dark Brown 286 OF (141 °C) 02569A 170 OF (76 °C) 150 OF (65 °C) Dark Brown l Based on NFPA-1 3, Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. [WARNING Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation Instructions. Data pages are Included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vlkinggroupinc.com. Form No. F 091699 18.10.11 Rev 16.1.P65 Replaces Form No. F091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern. A closed or sealed sprinkler refers to a complete assembly, including the thermosensitivo operating element, An open sprinkler does not use an operating element and Is open at all times. The distribution of water is intended to extinguish a fire or to control Its spread, Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles, finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or WARNING: Cancer and Reproductive Harm- approval agency listings. • www.P65Wamins.ca.gov TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)]. Sprinkler Identification: Viking sprinklers are identified and marked with the word "Viking", the sprinkler identification number (SIN) consisting of "VK" plus a three digit number*, the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion-resistant coatings or are fabricated from non-corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification. Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum-reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion, depending upon sprinkler location, occupancy classification, commodity classification, storage height, and other hazards. In all cases, the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors. The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER: A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella-shaped spray pat- tern downward. Marked "SSU" (Standard Sprinkler Upright) or "UPRIGHT' on the deflector Viking Technical Data may he found on PENDENT 5PRlN1J..EJ; A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at tor below the frame so water flows downward through the orifice, striking http://www.vikinggroupinc.com. the deflector and forming an umbrella-shaped spray pattern downward. The Web site may include a more recent Marked 'SSP" (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER: An 'old style" sprinkler intended to be installed with the deflector in either the upright or pendent position. The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers. DO NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P" (Conventional Upright/Pendent) on the deflector. Form No, F080814 18.12.06 Rev 14.1.P65 Replaces Form No, F 080814 Rev 14.1 (Added P65 Warning.) Page 2 of 3 The Viking Corporation, 210 N industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©viklngcorp.com Y&ICALSIPEWAL SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked "SIDEWALL' on the deflector with an arrow and the word "FLOW". (Note: Some vertical sidewall sprinklers can only be installed in the upright or pendent position—in this case, the sprinkler will also be marked "UPRIGHT" or 'PENDENT".) A sprinkler intended for installation near the wall and ceiling. The special deflector provides a water spray pattern outward in a quarter-spherical pattern. Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler. The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL" and "TOP" with an arrow and the word "FLOW". 9XIgN1211P CQVERAG (c) SPINKLR: A spray sprinkler designed to discharge water over an area having the maximum dimensions Indicated in the individual listings. Maximum area of coverage, minimum flow rate, orifice size, and nominal K-Factor are specified in the individual listings. EC sprinklers are intended for Light-Hazard occupancies with smooth, flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". QQJCK. RSPONS (OR) SPRlNKLR; A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED QOVERAGE (OREC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response. QREC sprinklers are only intended for Light Hazard occupancies. The sprinkler is marked "QREC". FLUSI4 5PRlNK1ER: A decorative spray sprinkler intended for installation with a concealed piping system. The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked 'SSP", "PEND", or "SIDEWALL" and "TOP". CONCEALED SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall, During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". RECESSED SPRINKLER: A spray sprinkler assembly intended for installation with a concealed piping system. The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON. CORROSION-RESISTANT SPRINKLER: A special service sprinkler with non-corrosive protective coatings, or that is fabricated from non-corrosive material, for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER: A special-service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklersare marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the coiling or wall]. LARGE DROP SPRINKLER: A type of special application sprinkler used to provide fire control of specific high-challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella-shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra-large orifice with a nominal K-Factor of 11,2. Marked 'HIGH CHALLENGE" and "UPRIGHT". EARLY SUPPRESSION FAST-RESPONSJ MEW SPRINKLER: A sprinkler intended to provide fire suppression of specific high- challenge fire hazards through the use of a fast response fusible link, 14.0, 16.8, or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high-momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Marked "ESFR" and "UPRIGHT" or 'PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER: A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly. Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER: A sprinkler intended for use in the following occupancies: one- and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13, Form No, F080814 18,12.06 Rev 14.1.P65 Page 3 of 3 N411aw*j II1M.4 7M SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs©vlklngcorp.com Residential sprinklers have a unique distribution pattern and utilize a "fast response" heat sensitive operating element. They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction, in addition to standard markings, the unit is identified as RESIDENTIAL SPRINKLER" or "RES" , INSTALLATION Refer to appropriate NFPA installation Standards. OPERATION Refer to the appropriate sprinkler technical data page(s). INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 jor inspection, Testing and Maintenance requirements. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT: Always referto Bulletin Form No. F_091699 -Care and Handling of Sprinklers and the appropriate sprin- kiergeneral care, installation, and maintenance guide. Viking sprinklers areto be installed in accordancewith the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,wheneverapplicable. The sprinkler technical data page may contain Installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to Installation. Form No, F080814 18.12.06 Rev 14.1.P65 Replaces Form No, F080814 Rev 14.1 (Added P65 Warning.) Page 1 of 1 N II(II1G REGULATORY AND HEALTH I WARNINGS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking websito for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided horin as they relate to legally mandated jurisdictional regions. A WARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to lead nickel, butadiene titaninum dioxide chromium carbon black and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more Information, go to www.P65WarnIngs.ca.gov WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No. F 111218 18.11.15 Rev 18.1 New Bulletin Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikIngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area, Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Etectroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®ui cULus Listed: Category VNlV FM Approved: Classes 2013 and 2015 zt WARNING: Cancer and Reproductive harm- www.P65Wamings.ca.gov NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart I and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34,5 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10,0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS.C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNSS30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Form No. F031793 19.10.14 Rev 19.2 Replaces Form F_031793 Rev. 19.1 (AflrlM FNT tinr1tr1 FM Innnimrip 'i VIKING o7297Q INA Sprinkler 'drench 7565'd/B** must be used for installing recessed dry sprinklers U- Step 2 Carefully press the wrench upward and turn slightly to ensur engagenent with the sprinkler wrench Flats, *wA 1/2' ratchet is required (Not avail- able From Viking.) Step 1 slide t sideways sprinkler -. - Page 2 of 6 QUICK RESPONSE NIIQ 1:c A DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkInggroupinc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ('A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The 'A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved In lengths from 1-1/2" to 45-1/2" (38,1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76,2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order' basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm), Adjustable Standard Dry Pendent up to 63-1/2' (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm), Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W. and ENT = JN Temperature Suffix: 155 OF (68 "C) B, 175 OF (79 "C) ID, 200 OF (93 "C) = E, 286 OF (141 "C) = G For example, sprinkler VK176 with a Chrome finish and a 155 OF (68 "C) temperature rating, and "A" length of 10" = Part No, 08383UFB10, Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book,) Sprinkler Wrenches: Standard Wrench; Part No. 07297W/B (available since 1991) Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) ""A 1/2"/ ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954), Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No, 07741 Recessed Dry Escutcheon Cup: Base Part No, 05459A INSTALLATION Refer to appropriate NFPA Installation Standards, OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 07297W/B Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F 031793 19.10.14 Rev 19.2 Page 3 of 6 'iJ II(IIIG ® QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N industrial Park Drive Hastings MI 49058 Telephone: 269.945-9501 Technical Services: 877384.5464 Fax: 269-818-1680 Email: techsvcscvikIngcorp,com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com ViT;II*AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES SprinIcler Temperature Sprinkler Nominal f6Samum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color Ordinary 155 9F (68 °C) 100 °F (38 )C) Red Intermediate - 175 9F (79 °C) 150 9F(65 °C) Yellow Intermediate 200 F (93 C) 150 F (65 °C) Green High 286 °F (141 °C) 225 iF (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3'4: White Polyester and ENT in all temperature ratings Footnotes The sprinkler temperature rating Is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies Indicated In the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When Installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For 'A' Dimension: 1. Deter-nine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2' (12,7 mm) between 1-1/2' and 45-1/2' (38,1 mm and 1,156 rim). NOTE: The deflector will be Located approximately 3-7/16' (87.3 mm) below the ceiling. with 1' (25.4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. NOTE: To locate the deflector at the minimum distance below the ceiling, with no downward adjustment A Minimum ceiling opening c\j_ ,4-'7/16' available, order the T t:;jp diameter: 1-3/4' (44.5 mm). (61.9 mm) dry pendent sprinkler ximum ceding opening JL_mum Mini I diameter: than the 'A' dimension. _____ NOTE Finished mm) To locate the deflector Ceiling I at the maximum distance 4-7/16' below the ceiling, with V 1-1/2'-------'-- Sleeve finish I 1(112.7 mm) no downward adjustment (38.1 mm)matches escutcheon. I,_J Maximum available, order the diameter dry pendent sprinkler 1" (25.4 rim) longer (77.8 mm) than the 'A' dimension, Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler Form No, F 031793 19,10.14 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877.384-5464 Fax: 269-818-1680 Email. techsvcsvikingcorp.com Visit the Viking webslte for the latest edition of this technical data page: www.vlkinggroupinc.com Approval Chart I (UL) j Temperature KEY Quick Response Dry Pendent Sprinkles Finish Maximum 175 PSI (12 bar) WWP ll X 1 - Escutcheon (if applicable) Sprinkler Thread Size NominalK.Factor Order Length Increment Listings and Approvals' Base Part No. SIN Style NPT BSP U.S. metric' Inches mm cULus5 NYC6 Vd$ L.PCB CE VK176 Adjustable Standard 1 --5,68Q 1/2" 1-2,,7-, A1A Al - 16457U 25 mm 8016 1/2' 12,7 All, A5 -- 08385U VKI8O Adjustable Recessed 1" SM 80.6 1/4" 6.35 82, 86 82 -- 16453U -- 25 mm 80,6 1/4" 6.35 82, 86 -- - -. - 08387U 17 VK 2 Plain Barrel 1" -- 5,6 80,6 1/2" 12.7 A3 A4 -- 16455U -- 25 mm -" 80,6 1/2" 127 A3 -- -- Approved Finishes and "A" Dimensions - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon Approved Temperature Ratings with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) A - 155 "F (68 "C), 175 "F (79°C), 200 "F (93 "C), 2 - Chrome or White Polyester7 with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) and 286 "F (141 "C) 3 - Chrome, Brass, White Polyester7, or ENT with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) B - 155 "F (68 "C), 175 "F (79°C), and 200 "F 4-Chrome or Brass with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) (93 "C) 5 - ENT sprinkler with an ENT7 Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) .6 . EN with "A" dimensions 3-1/4" to 47-1/2"(82.5 mm to 1,207 mm) Footnotes Part number shown Is the base part number, For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown Is when pressure Is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process, Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada, 6 Accepted for use City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. cULus Listed as corrosion resistant. DESIGN CRITERIA -_Uk (Also refer to Approval Chart I above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-5-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, Designed for use In Light and Ordinary Hazard occupancies. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed, IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F 031793 19.10.14 Rev 19.2 For "A" Dimension Determine the distance From face of tee to the finished ceiling. Round to nearest 1/4' (6.35 mm) between 3-1/4' (82.5 mm) and 47-1/2' (1,207 mm). JTE: Sprinkler will be recessed approximately 5/16' (7,9 mm) above the finished ceiling with 5/8' (15.8 mm) vertical adjustment available, ished ceiling lecqd Dry Pendent Sprinkler Minimum ceiling 2-1/8' (54 rim) Maximum ceiiin 2-1/2' (63.5 mr Adjustment: 5/16' (7.9 mr 5/16' (7.9 mr Minimum: 1' (25.4 mm) Maximum: 1-5/8' (42.1 m Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viklnr wPbsltA fnr the latest edition of this teihniaI data nanp wwwvlkinnnrn.inlni m Approval Chart 2 (FM) jTemperature KEY Quick Response Dry Pendent Sprmnklrs ' *f' FsniSh Maximum 175 PSI (12 bar) IP LjX4--Escutcheon(lfapphcabie) Sprinkler Base SIN Style Thread Size I Nominal K-Factor2 Order Length Increment FM Approvals' NPT ASP U.S. metric5 Inches mm Part No.' (Refer also) to Oesin Criteria below.) 083830 VK176 Adjustable Standard 46 1" 5,6 80.6 1/2" 12,7 Al 164570 mnd 806 i - - 083850 VK180 Adjustable Recessed 1" 5 6 80.6 1/4" 6.36 82 164530 25 mm - - 806 1/4 6 35 B2 083870 VK172 Plain Barrel 1" 60.6 1/2" 12.7 A3 164550 25mm - 806 1/2 127 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A- 155°F (68 °C" 175 °F(79 "C) 200°F (93 I - Brass, Chrome, White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or /4.44 an r p ENT5 Sleeve and Escutcheon with A dimensions 1-1 /2 to 45-1/2' (381 mm to 1156 mm) 2 Brass Chrome White Polyester, or ENT5 with A dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) B - 155°F (68 "C), 175°F (79°C). and 200°F (93 °C) 3- Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number, For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ('A" Dimensions indicated above), Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Aooroval Reauirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as Indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, L.PCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. E1__1B 41TFor 'A Dimension: A 1. Determine the distance from Outside -.. the face of the diameter: \ tee to the base 1-5/16 of the sprinkler. (334 mm) 2. Round up to the (same as next highest 1/2' 1' (25 mm) (12.7 mm) incre- Schedule ment between 3' 40 pipe). (76.2 mm) and 47' (1,194 mm). 1':48 . 1-5/8' 3 mm) Figure 5: Plain Barrel Dry Pendent Sprinkler Page 66 of 6 'II 11a:N7G QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email; techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggroupInc.com Ambient Exposed Barrel Ambient Temperature Temperature 40'F/4'C150'F/10C160'F/16C of Protected Area*t the Exposed Minimum Barrel Discharge End Lengthu Face of lee of the Sprinkle to Top of Ceiling ) Im mm) mm) 40T (4'0 0 1 0 0 30F (-PC) 0 0 0 20'F (-7'C) 4(100) 0 0 10F (-12'0 8(203) 1(254) 0 OF (-180 12 (305) 3(76) 0 -10F (-23'0 14 (356) 4(102) 1(25.4) -20F (-290 14(356) 6(152) 3(76) -30'F (-34'0 16 (406)8(203) 4(102) -40'F (-400 18 (457) 8(203) 4(102) -50F (-460 20 (508) 10(25(152) -60'F (-51'C, 20 (508) 10(254$6 (152) 1 inch NFl threaded /-Install Deflector at end of dry pendent sprinkler minimum distance into the 1 inch NPT outlet below ceiling of a mafleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting Up to 2' (50.8 mm) per ANSI 16.4 (Class 125) only. _ adjustment available. Note Minimum 'nimum ceiling opening diameter: M--- To locate the (Exposed /4'(44.5 mm) ______ ____ deflector at the Barrel) minimum distance rMaxi mum ceiling opening diameter: 2-1/4' (57 mm). 7/l6 below the ceiling. ___Y(61.9 mm) with no upward Seal the clear-arce adjustment avail- space around the able, order the sprinkler to avoid leak- -- inimum dry pendent sprink- ter 1' (25.4 mm) age of air into the :::::''cZ:::::_ shorter than the 13/16 protected area and ,,.,+formation 'A' dimension. j (20.6 mm) '""' Ceiling of condensate around the frame, which could Note: inhibit operation or To locate the 1-1/2' (38.1 mm) Sleeve finish cause premature opera- 4-7/16' deflector at the matches tion. Refer to Figure (112,7 mm) maximum distance Maximum with no nward diameter below the ceiling, escutcheon 7 below. IF humidity and temp- adjustm erature differential ent dow avail- able, order the causes condensation I dry pendent sprink- (Protected Area) (77.8 mm) on the exposed dry ter 1' (25.4 mm) sprinkler, consider longer than the wrapping the exposed Deflector at 'A' dimension. barrel with insulation, maximum distance Foam insulating tape, below ceiling or equivalent. 1( The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values Listed, use the next cooler temperature. wwlhe minimum required barrel length is not the same as the 'A' dimension. Refer to Figures 3-5 For the 'A' dimension. NOTE Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendant Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendant Sprinkler is Shown) Form No. F031793 19.10.14 Rev 19.2 Replaces Form F031793 Rev. 19.1 (Ar1r1M FNT sonrIWAH FM Pnnpppir,i c®us ILl$11IE <> APPROVED t4FPN " SCHEDULE ID PIPE SPECIFICATIONS - - -- .. - NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1820 91 1-114 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1(2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-114 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa GrandeAZ "Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket. pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 6M sales@bulImoosetube.com 1819 Clarkson Road Chesterfieki,MO GeraktMO Ken1WA Casa Grande, Z Dallas, IX Mas0H 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other, fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube.'sP Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM AI;23 standards. All products are stencilled to meet FM & UL specifications. BuR Moose Thbe'® Eddythread40 ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40° is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of t. • is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MlC preventative coating. EDDYTHREAD 4011 SPECIFICATIONS ONE NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LBJFT WEIGHT SIZE 1 1.295 1.083 1-114 1.650 1.418 1-1/2 1.900 1.654 2 2.375 2.123 *Corrosion Resistance Ratio per latest UL Directory Listing 1.00 1.461 1.860 70 1.00 2.070 2.754 51 1.00 2.547 3.468 44 1.00 3.308 4.842 30 LISTED <> APPROVED 0,01 omm NFPX PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips. grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com "W" Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerak!, MO Kent. WA Casa Grartde AZ Dallas, TX MasurA ON 63017 5 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wail thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness Less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UI. UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.100 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 *Corrosion Resistance Ratio per 'atest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fining used. For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 saJes@bullmoosetube.com 1819 coa Road 6M chest&liektMo GeraktMo Kent,wA Casa Grande,Az DaIa1X Masur0H LMOOSEtECWIPW 63017 Bull Moose Tube's Eddylite® is a lightwall threadable, pipe manufactured in NPS t" through 2". Eddy1ite' is a truly unique product within the fire protection industry, This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wail thickness, or standard outside diameter. Eddylite is manufactured to meet the requirements of AST, M35 and A795 specifications. This pipe product has been fully, approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada for use in fire protection systems with a working pressure of 300 psi or Less. ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD 110 MIC preventative coating. NPS O.D. EDDY FLOW" WEIGHT WATER FILLED BUNDLE EDDY FLOW SIZE (IN) (IN) (ID) CRR* PER Ft Wt SIZE 1.98 1.222 2.019 61 3.44 1.844 2.860 61 2.78 2.330 3.982 37 1.66 2.809 5.299 30 1.00 3.361 7.144 19 1.00 4.968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald. MO Kent, WA Casa Grande, AZ Dallas, TX Masurt0H 63017 7 Bull: Moose Tube's® Eddy Flowla is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (or U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery, costs and ease of handling. Furthermore. Eddy Flow' larger ID provides an opportunity for downsizing and further cost savings. 1-114 1.660 1.530 1-1/2 1.900 1.728 2 2.375 2.203 2-112 2.875 2.705 3 3.500 3.334 4 4.500 4.310 Dull MooseThbe's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY U a versatile product that can be • Certified to ASTM A135 and A795 Type E, Grade A. roil grooved, welded, and used with -. FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • Ui. listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule S tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS - O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FIU.EDWL SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 * Pressfit is a Registered Trademark of Victaulic Company of America Corrosion Resistance Ratio per latest UI Directory Listing c®us LISTED <> APPROVED (] 4 OMA NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande,AZ Dallas, TX Masat OH .LL T5cWNY 63017 NPS(tN) 1 1-114 1-1/2 2 2-112 3 4 c®usll.IS11EEtDi APPRM () 4 OMM NEPA 01)(in) 1.315 1.660 1.900 2.375 ID. (in) 1.201 1.546 1.786 2.261 ULTRA 1EDDY6 Empty Weight (b/ft), 0.868 1.107 1.274 1.604 11ter-RlfedWeight(tb/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 0.D.(in) 1.660 1.900 2.375 2.875 3.500 4.500 LD.(in) 1.530 1.728 2.203 2705 3.334 4.310 EDDY FLOW'm Empty Weight (lb/ft) 1.222 1.844 2.330 2.809 3.361 4.968 Water-Filled Weight, 0b/ftY 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 344 2.78 1.66 1.00 1.00 6. D. 1.315 1.660 1.900 2.375 2.875 3.500 4.500 LD n) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 10 SCHEDULE Empty Weight (lb/f 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Vter-RlledWeight(lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 CR.P, 15.27 9.91 7.76 6.27 4.92 3.54 2.50 aDL(n) 1.315 1.660 1.900 2.375 - i.D.(in) 1.137 1.482 1.712 2.177 EDDYLITE6 Empty Weight (b/ft 1.260 1.617 1.967 2.617 - tet4iL1edWeigffl(lWft) 1.700 2.364 2.965 4.230 C.R.R. 013 008 012 016 0.D.(in) 1.295 1.650 1.900 2.375 EDDYTHREAD f.a(in) 1.083 1.418 1.645 2.123 40® Empty vwight(Ib/ft) 1.461 2.070 2.547 3.308 Vter-R[Ied Weight (tb/fr) 1.860 2.754 3.468 4.842 - C.R.R. 1.00 1.00 1.00 1.00 O.D.(in) 1 315 1.660 1.900 2.375 2875 3.M 4.500 SCHEDULE 1.049 1.380 1.610 - 2.067 2.469 3.068 4.026 40 EmptyWeightab/ft) 1.680 2.270 2.720 . 3.660 5.800 7.580 10.800 Water Filled Weight (tMt) 2.055 2.918 3.602 5-114 7875 10.783 16.316 - C.R.R.100 100 100 100 100 100 100 For Additional Information Contact (800) 325-4467 www.buflmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1S19 Clarkson Road Chesterfield, MO Gerald, MO KentWA Casa Grande, AZ Dal141X MaauiYOH 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE c®Us ILlS1IE IDJ ULTRA EDDY® 0.868 91 1.659 1,896 1.975 SCHEDULE TO 1.410 91 2.695 3,079 3,208 1 EDDYLITE® 1.260 91 2.408 2,752 2,867 EDDYTHREAD4O® 1.461 70 2,148 2,454 2,557 SCHEDULE 40 ULTRA EDDY® 1.680 1.107 70 61 2.470 1,418 2,822 1,621 2.940 1.688 EDDY FLOW® 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2,760 1114 EDDYLITE® 1.617 61 2,071 2,367 2,466 EDDYTHREAD40 2.070 51 2.217 2,534 2.639 - - SCHEDULE 40 2.270 51 2,431 2.778 2.894 ULTRA EDDY® 1.274 61 1.632 1.865 1.943 EDDY FLOW® 1.844 61 2.362 2,700 2,812 SCHEDULE 10 2.090 61 2.677 3,060 3,187 I EDDYUTE® 1.967 61 2,520 2,880 3,000 EDIYYIHREAD 40® 2.547 44 2,353 2.690 2,802 SCHEDULE 40 2.720 44 2,513 2,872 2.992 ULTRA EDDY® 1.604 37 1,246 1.424 1,484 EDDY FLOW® 2.330 37 1.810 2,069 2.155 SCHEDULE 10 2.640 37 2,051 2,344 2,442 2 EDDYUTE® 2.617 37 2,033 2,324 2,421 EDDYrHREAD 40® 3.308 30 2.084 2,382 2,481 SCHEDULE 40 3.660 30 2,306 2,635 2.745 EDDY FLOW® 2.809 1,770 2,022 2.107 2-1/2 SCHEDULE 10 3.530 30 2.224 2,542 2,648 SCHEDULE 40* EDDY FLOw® 5.800 3.361 3.654 1,341 4,176 1,533 4.350 - 1.596 3 SCHEDULE 10 4.340 19 1.732 1,979 2,062 - SCHEDULE 40* 7.580 3,024 3,456 3,601 EDDY FLOW® 4.968 1,982 2.265 2.360 4 SCHEDULE 10 . 5.620 19 2,242 2,563 2,670 SCHEDULE 40* 10.800 4,309 4,925 5,130 6 SCHEDULE 10 9.289 10 1,951 2.229 2.322 L8 SCHEDULE 10 AZ. 16.940 7 2,490 2,846 2.965 * Only Available in Casa Grand®, APPHOVED njo 4_ pwpx - 10 Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (FpwI lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Bra~e Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 14 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 112 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 1 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20ff. 25ff. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1 1/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 f 40 40 40 36 33 30 29 27 26 24 23 BULL IVIDOSE TUBE COIVIRANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.buflnioosetube.com sales@bullmoosetube.com c®us LISTED APPROVED [4,01 44!!4 - For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road 6M Chesterfiekl,MO GeraktMo Kent WA Casa GrandeAZ Daibs,TX Masui0H 63017 11 MechanicaIT0 STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a 'holefinder" locating collar which secures the outlet in position permanently, A pressure responsive gasket seals on the pipe 0,0. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical.T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts, Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe, Standard piping practices dictate that the Mechanical.T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45.12, with orange enamel coating, Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOSIOWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect - Para_________ Location Date Approved Date_____________________________________ www.victaullc.com VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 V!CTAUUC COMPANY. ALL RIGHTS RESERVED. REV_N .,J6tauIic CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 MechanicalP Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. (1W-h 00Wit r ntht5 r h 2 5 (a) 2< 920¼ 500 1.50 2.00 2.53 .61 5.35 2.75 3.1 50 15 3450 381 51 64 41 136 70 1.5 ~ ,a> 920¼ 500 .50 1.97 2.53 - 1.61 5.35 2,75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a) 920¼ 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 - 70 (.4 1 1/4 (a) tu 920¼ 500 1,75 2,05 2,75 3.00 1 61 5.35 3.00 3.5 3.2 32 3450 445 52 70 76 41 136 - 76 1.7 1.5 1½ (a) 55 2 500 ' 1,75 2.03 2.75 3.12 1.61 ' 5.35 3.25 3,6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2½ ½ (alta 2< ¼ °' - Soo 150 ' 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 381 56 70 46 143 70 1.4 YA (a) te 020's 500 1.50 2.18 2.74 1.82 5.64 2.75 ' 3.0 20 3450 381 55 70 ' 46 143 70 14 1(a) 500 1.50 2.06 2.74 1.82 5.64 - 2,75 2.9 25 3450 38.1 52 70 , 46 143 70 1.4 1½ 5(a) P 20 500 (.75 2.30 3.00 3.25 1.82 6.29 3,00 3.5 3.2 32 3450 44.5 , 58 76 83 46 160 76 1.7 1 1½t(a) a 9 201 500 2.00 2.28 300 3,25 ' 1,82 6,26 3.25 3.6 ' 33 40 3450 50,8 58 76 83 46 i59 83 1,7 1.6 20716.1 300 .50 2.22 2.75 2.25 ' 6.46 ' 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 1.8 - '/4 920¼ 300 ' 1.50 2.19 - 2.75 2.25 ' 5.46 3.18 3.9 20 , 2065 38.1 56 70 57 164 , 81 1.8 - 1 IPi 920¼ 300 1.50 2,07 2.75 2.25 6,46 3.18 ' 3.8 25 2065 , 38.1 53 70 , -- 57 IrA , 81 1,7 (¼ (a) C 920¼ - 500 1.75 2.30 3.00 3.31 1,92 6.29 3.00 3.5 3,2 32 , 3450 44.5 58 76 , 84 - 49 160 76 , 16 1.5 (½ (a) n 500 -- 2.00 2.28 3.00 331 1,92 6.29 3.25 3.5 3.3 40 , 3450 50.8 58 75 84 49 160 83 1.6 1.5 - 3 ½ (a) P 2< 9 "ON 500 1,50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - N (a) C ,. 500 1,50 2.49 3.05 - 2,28 ' 5.15 2,75 3,4 20 92'uN ' 3450 38.1 63 78 - 58 156 70 1.6 1(a) 920¼ 500 1.50 2.33 3,06 2.28 6.15 2,75 3,3 25 3450 38.1 , 61 , 78 - 58 156 70 1.6 I ¼ 131 Sri , 9 500 - 1,75 2.55 3,25 3,56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 ½ )a) to -. - , 500 2.00 2.78 -4 - 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 L9 (.8 920¼ ' 500 2.50 2.75 3.50 3.56 ' 2.28 6.75 3.88 4.9 4,6 50 3450 635 70 89 90 58 172 99 2.3 2.1 3/2 2 2< 923¼ 500 250 300 j' 370 244 672 388 F at 90 50 ' ' 3450 63.5 76 I 95 52 171 99 I 1.8 TABLE CONTINUED ON PG. 3 ° Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order, * Center of run 10 end of fitting. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings, (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order (b)For 76,1 mm threaded outlet, specify 2½" BSPT clearly on order. 'Ids approved for fire protection services C PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. -Y Z F 11 1 1 t - +V~ r-r_ :-71 IR GROOVED OUTLET V 0 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 1103 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 47200 x 100 mm www.vlctaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY, C 2017 VICTAULIC COMPANY, ALL RIGHTS RESERVED. uctaubc 11.02.2 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-To Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 4 ½ (a) a I 9201 500 1.50 303 3.56 2.69 7,01 2.75 37 100 15 3450 38.1 77 90 68 178 70 1.8 ~(a) 500 1 .50 3.00 3.56 2.69 7,01 2.75 3,7 20 j 3450 38.1 76 90 68 178 70 1 8 (a) a 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 48 178 70 1,8 1¼(a)± 920N 500 1.75 3.08 3.76 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 '78 76 1.9 1.8 1 ½ (a) tp 920N 500 2.00 3.28 4.00 4.00 269 7,Qi 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 '78 83 2.0 1,9 2 (a) ta 920N 500 2.50 3.25 4.00 4.00 2.69 7101 3,88 5.0 4,6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 2½ (a) S 920 500 2.75 188 4.00 400 2.69 7.34 - 4.63 5.8 5.0 65 3450 69.9 73 - 102 102 68 186 119 2.6 2.3 76.1 mm 500 2,75 2.88 4.00 2.69 734 ' 4.63 6.4 3459 69.9 73 - 102 68 186 , 118 ,• , 2.9 a Ia; C 90 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 , 88.9 84 114 105 , 58 196 , 130 3.8 2.9 mao y 1 920N 500 1.75 3.08 3,76 2.63 7.64 3.05 5.0 - so 44.5 78 99 , 67 134 78 2.3 ½ (a)a 20N 500 2,00 3.28 4.00 2,63 7,54 3.25 5.0 43 3453 50.6 83 102 67 194 83 2.3 - 2(a) 920V ' 500 2.50 3,25 4.00 2.63 7.54 4,00 4.0 50 3450 63.5 83 102 - 67 194 102 L9 - 76.1 mm 920 ' 2.75 2 88 4.00 4.00 ' 2.63 7.64 4.29 8.0 7.8 3450 69.9 73 102 , 102 67 194 109 3.6 3.5 3)a) 920500 3,503.31 4,53 4.50 2,63 7.63 4.88 6.8 r.5 80 3450 86.9 84 114 114 67 194 124 , 3,1 3.0 5 1,5 a) t 20 Soo 200 403 475 475 16 979 69 74 76 125 40 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a) 6 -0 500 2.50 - 4...... 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 345063,5(02 121 121 80 246 111 3.7 3.6 2½ (a) - o 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3453 69.9 -4- 92 121 121 80 246 118 3.8 3.6 920 500 2.75 3.75 - 4.75 316 9.70 - , 4.63 - 8,0 3450 69.9 95 121 80 246 18 3.6 7~8~ao)t 500 3.50 3,81 5.00 4.63 3,16 9.70 5.31 8,4 8,8 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 ' 5002.503.75 4.50 3.17 8.003.888.0 b3.0 x 9201 3450 63.5 , 95 114 - 81 203 99 3.6 - 3 -. ' 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 3450 88.9 97 127 - 76 240 135 3,6 - Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 21/Y" BSPT clearly on order. § Vds approved for fire protection services u LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company, Y rr- z 7-11 GROOVED OUTLET * hl~Z-51'11 1 4111 no-s-, FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½'YSO x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.vlctaullc.com ictsulid vicauuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 201 VICTAUL;C COMPANY, ALL 9101-ITS RESERVED, EVJ 1.1,02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 MechanicalP Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 1) i1YIb O3' ' I4 WD ~' c tg 0 0 V j Ifl 4 )4-Z--- Vo O TABLE CONTINUED FROM PAGE 3 1½ 500 2 0 375 4,50 30 23 325 7.0 40 3450 508 96 114 84 29S 83 3.2 2t 20¼ 500 2,50 3,75 4.50 3.30 820368 9.0 -- - 50 3450 63.5 95 14 84 209 99 4.1 - W - 6 1 ¼ (a) 920¼ 500 (.75 4.43 5.13 5,13 3.79 9.15 3,25 5.1 4.8 150 32(b) 3450 445112130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'/2 (a) tto 92ON 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 49(b) 3450 50.8 112 130 130 96 232 83 2.4 - 2.3 2(a) t ., 9231 500 2.50 4,38 5.13 5.13 3.79 915 3.88 6,3 5.6 3450 63.5 lii 130 130 96 232 99 2.7 2.5 2 112 500 2.75 4.01 5,13 5.12 3.69 10.51 4.63 8.3 7.6 92 . 3450 699 110 130 130 94 267 118 38 3.4 V ' 920 500 2,75 4.15 ' 5.21 359 0.51 ' 4.63 5.4 761 T ' ° 345069.9 105 13294267 115 3.8 - -- - 3(a)3 920 500 ' 3,50 4,31 5.50 5.13 3.59 10,51 5.31 9.9 8.4 w 80 , 3450 88.9 i 1 , 140 , 130 94 , 267 135 4.5 3.8 4 (a) to ' 500 4,50 3.81 5.75 5.38 3.69 10,51 6,25 ' 10.1 10.1 100 3450 114.3 97 146 (37 94 267 159 4.6 4.6 FEMALE THREADED OUTLET -'' < i/2 - (/2(a) 923'4 500 2.00 4.41 5.13 63 9.43 .2.25 7.8 40 3450 50.8 112 130 - .. 92 239 33 3,5 - 4 . - 2(a) , 500 2.50 4.38 513 3.63 9,40 3.88 8.3 Provides a direct branch connection at so 923N 3450 63.5 111 130 - 92 239 99 3.6 - any location where a hole can be cut 761 920 500 2.75 4.38 5.50 - 523 3.63 9.40 4,63 9.5 9.5 in the pipe - 3450 699 U 11 140 hO 92 239 118 43 43 3 L .. 500 3.50 4,31 5.50 5,13 3.63 9.40 5.31 8.1 14.0 A pressure responsive gasket provides 80 3450 88.9 ((0 140 (30 92 239 135 3.7 6.4 the seal 108 Oem 920 500 4.50 4,45 - 5.38 3,63 9,40 6.12 - 10.0 3450 114,3 113 , 137 92 239 155 4.5 Request Publication 11.03 for a 920 500 450 3.81 5,75 - 3,63 9.40 6,25 - 18.0 Mechanical-T cross assemblies 100 - 3450 , 114.3 96,80 46 92 239 , 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order, with HDPE pipe * Center of run to end of fitting. Sizes from 2 x ½'YSO x 15mm # Female threaded outlets are available to NPT and BSPT specifications, through B x 4/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order. (b)For 76,1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot he mated to one another to achieve cross connections. www.vlctaullc.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY, 0 2017 ViCTAUUC COMPAN'6 ALL RIGHTS RESERVED. iCtauIC i1O2,4 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi13450 kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x 1/2/50 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 MechanicalT'' Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS _;r fJ rI4ir 7 8 °:'AM ii Z TABLE CONTINUED FROM PAGE 4 1 155.1 >r 920,\l 500 1.50 388 4.56 3.79 2.34 2.75 80 25 3450 38.1 99 116 96 237 70 3.6 500 175 4,43 5,13 - 3.79 9.34 - 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 1½(a)t 904 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2(a)t 920"4 500 ' 2.50 4.38 5.13 5.13 3.79 9,34 3.88 8.5 6.0 50 3453 53.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 - 4,01 5.13 5.21 3.63 10.51 4,63 8.6 7.6 3450 699 110 130 132 92 287 118 3.9 3.4 920 500 3.50 4.31 5.50 ' 513 3,63 1,511 5.31 10,2 8.4 80 3450 85.9 110 140 130 92 267 135 4.6 3.8 4(a)w 920 500 450 - 3,81 5,75 5.38 363 1151 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 ;59 4.8 3.8 5 2 (a) t 92 500 2.75 5.44 6,19 6.25 4.81 12,42 4.50 11.6 11.6 200 50 3450 69.9 138 157 159 122 316 114 , 5.3 5.3 920 500 275 5.07 6.19 6.19 4,81 12.42 4,50 11.6 11.6 65 3450 , 69.9 129 157 157 122 516 114 5.3 5.3 76 .lmm ' 920 100 2.75 5.25 6.25 4,81 342 4.56 11.6 3450 69,9 133 159 122 316 116 -53 3ta) t ' 920 500 3.50 5.31 6.50 6.50 4.81 2.42 ' 5,31 2.6 11.6 80 ' 345088.9 '35 165 165 122316 135 5.7 5.3 4(a) t 920 500 4.50 4.81 8.75 6.38 4,81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 318 159 69 5.7 ' Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet, Specify choice on order. * Center of run to end of fitting, S Female threaded outlets are available to NFl and BSPT specifications, @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" 8SPT clearly on order, S Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company IMPORTANT NOTES: Style 920 and Style 9201\1 housings cannot be mated to each other to achieve cross connections. www.vlctaulic.com Ateuba VICTAULIC IS A REGISTERED TRADEMARKOF VICTAIJLIC COMPANY, 2017 VICTAULIC COMPANY, ALL RI ic GHTS RESERVEO, REV_" . I1.02 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 MechanicalP Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T fittings can best be expressed in terms of the pressure difference across the inlet and branch, The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/--1°C are shown in the table below. TL Formulas for Cv 1K, Values: AP =Q2 Where: p = Q2 Where: 44 141 V c2 Q= Flow (GPM) jT Q= Flow (m3/hr) () ) Q = :Pressure Drop si) AP Pressure Drop (Bar) C, Flow Coefficient Q = K x j F K, Flow Coefficient Exaggerated for clarity OUTLET SIZE mah 11 140 catbon Steel Pipe 'm ' 0,840 - 5 213 94 N 1.050 4 6 20 - 157 . 37 1 1,315 .. a 21 25 337 - 1.8 1 ¼ - - 1 660 - - 6 50 48 32 427 42.9 41,1 1½ 1.900 Ii 53 53 40 98 45.4 45.4 2 ' 2,375 . . 12 104 50 60.3 96 89.1 2 1/2 2.875 20 12 V2 '• 119 150 65 73,0 102 128,5 3.000 76,1 mm 16! 76,1 '38 3 3.500 . -. 1 15 3 249 - - 237 80 889 23.4 203,1 ' 4,560 20 11 421 401 100 114.3 360.8 343,6 8 Hazer-Williams coefficient of friction Is 120, Pipe with a wall thickness of 0,165in 14.2mm. 1', FireLock' Innovative Groove System (IGS) outlet www.vlctaullc.com vlcrAuuc IS A REGISTERED TRADEMARK OF VIC1AUc COMPANY, 0 2017 VIcTAuLIC COMPANY, ALL RIGHTS RESERVED, X*41C—t a —U1 i ::f 11.02,6 REVJ CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 MechanicalP Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies, Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2875. 6,625 All 10,40 400 400 400 290 65.150 73.5.168.3 2755 2755 - - 2755 1995 21/2,4 2.875 4.500 All DF 300 300 300 290 65.100 730.1143 2065 2065 2065 1995 21/2-4 2875-4.500 All SF 300 - 300 300 290 65.100 73.0.114.3 2065 2065 2065 1995 6 6.625 3,4 0 300 - 300 250 290 ISO 168.3 2065 2065 1724 1995 6 6.625 34 30,40 300 300 300 290 150 68,3 ' . 2065 2065 - 2065 1995 8 8.625 21/2 10 40 400 - 200 219.1 2755 8 8.625 34 10 - 300 -- - 250 200 219.1 2065 1724 - 8 8,625 -- 3040 300 - 300 200 219.1 2065 2065 - NOTES; 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC-TAP II HOLE CUTTING TOOL FOR 4- 81100 . 200 MM CARBON STEEL PIPE The Vie-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical.T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vie-Ball Valve. The Vie-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical.T unit is a full port ball valve which can be mounted on 4/100mm, 57125mm, 6/150mm and 81200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.vlctaullc.com VICTA)JLIC IS6 REGISTERED TRADEMARK OF VICTAUUC COMPANY. 6)2017 VlCTAULlC COMPANY, ALL RIGHTS RESERVED, sctaulic 232 1599 232 1599 232 1599 232 1599 232 1599 145 1000 145 000 145 1000 362 2496 362 2496 362 2496 362 2496 362 2496 MechanicaI-T STYLES 920 AND 920N INSTALLATION Reference should always be made to the 110Q Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com, WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations, For complete contact information, visit www.victauliccom \4tauho' 11,02 1480 REV N UPDMW 12/2017 'IICTAULPC PS A REGISTERED TRADEMARK OF VICTAULIC COMPANY, © 2017 VICTALILIC COMPANY. ALL RIGHTS RESERVED. _________________ 1L02_L FireLock' STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1715, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. RIEVA \4taulic IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock'O Out1etT STYLE 922 DIMENSIONS a am L 32 15 30.2 . _ x 1.0 3 465 110 37 26 T -Y4 1Yi6 1.28 1.83 1.10 3.87 2.56 1.1 27.9 983 65.0 0.45 -. 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 6 w 1 1 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1'!, ½ 13'16 1.42 1.95 1.22 4,08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 1 3A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 1036 65.0 0.54 1 1 3A6 1.64 2.30 1.22 4.08 2.56 1.3 25 302 41.7 58.4 31.0 103.6 65.0 0.59 2 1/2 1 3A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 '/4 1 3A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3A& 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 x ½ 1,/'6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 Y4 1 3A6 1.89 - 2.44 1.71 5.40 2.56 ' 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3A6 2.13 2.79 1.71 5.40 2.56 - 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 761 mm X ½ 1/rn 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/~ 1 1,89 2.44 ' - 1.71 5.50 2.56 1.6 20 30.2 480 62.0 43.4 1397 65.0 0.73 1 1 3/16 2.13 - 2.79 1.71 5.50 2.56 r 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc, should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. 0 2009 VICTAuLIc COMPANY. ALL RIGHTS RESERVED. ictaul.c 10.922 IRS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock' Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com /tauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. _______________ REV-6 10,52.,3 FireLock' STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 Ictaulic vicrAulic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1042 D I I t.., I, p:''• SM1TH,.,C00PE1W INTERNATIONAL Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 cULus LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 FM Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 c®us ? Fig. 35E 3-90° Elbow LISTED Size in Part Number A in Packing Weight lb Inner Mãstér 1/2 35E 3004 1.13 100 200 0.2 3/4 35E3006 1.31 70 140 0,3 1 35E 3010 150 40 80 0.5 1-1/4 35E3012 1.75 25 50 0.8 1.1/2 35E 301 4 1.94 18 36 1,1 2 35E 3020 2.25 10 1 4 20 * 1.8 2.1/2 35E 3024 2.70 8 3.2 Fig. 33RE3 - 90° Reducing Elbow Size Part P rt Number A in B in Piiiii Weight lb -Inner I Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1x 1/2 358E3010004 1.26 1.36 1.45 70 140 100 0,4 0.4 1 x3/4 35FRE3010006 1.38 50 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 358E3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1,58 1.67 30 60 0,7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2xR 35RE3014006 1.52 1.75 25 20 50 07 1-1/2x1 35RE3014010 - 1.65 1.80 40 0.8 1-1/2 x 1-1/4 35RE3014012 1,82 1.88 18 36 1.0 2x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 ' 35RE3020012 1.90 2.10 12 24 1.3 2x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 11/2 35RE3024014 2.16 251 6 12 2,2 2-1/2 x 2 35RE3024020 1 2.39 1 2.60 1 6 1 12 2,5 Size in Part Number A in Packing Weight lb 'Inner I Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 35F3012 1.29 25 50 - 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F3024 1,95 4 8 2.7 t\I Fig. 35F 3-45° Elbow Fig. 35T 3- Tee Size in Part Number a e A Packing Weight lb 'ie,' .: Master - 1/2 35T 3004 113 80 160 0.3 3/4 - 35T3006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 1.1 1-1/2 35T3014 1.94 10 20 1,5 2 351 3020 2,25 6 12 24 2-1/2 351 3024 1 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 www.smirhcooper.com Size Part Number A ,Jn B in C in Packing Weight lb .. I Inner Master . 3/4x 1/2 35RT3006004 120 1.20 1.22 60 120 0.4 0.6 lx 1/2 35R13010004 1.26 1.26 1.36 30 30 60 1x1/2x1 1 x3/4 1 x3/4x3/4 35RT3010004010 1.50 1.36 1.50 60 0.6 35Rt3010006 1.38 1.38 1,45 145 25 50 0.6 06 35R13010006006 138 131 35 70 1x 3/4 x1 35RT3010006010 1.50 1.45 1.34 1.50 25 20 50 0.7 0.6 1-114x1/2 35RT3012004 1.34 1.53 40 1-1/4 x 112 x 1-1/4 - 1-1/4x3/4 35RT3012004012 175 153 1.45 17 25 50 09 35RT3012006 1.45 1.62 15 30 0.9 1-1/4x 3/4 x1-114 1-1/4x1 35R13012006012 1.75 1.62 1.58 1.75 1.67 20 40 1.0 1.0 35R13012010 1.58 15 30 1-1/4 x 1 x 1/2 35RT3012010004 134 126 153 25 50 07 1-1/4 x 1 x3/4 35RT3012010006 145 138 163 20 40 08 1-1/4x1x1 35813012010010 1.58 1.50 1.69 1.75 - 20 40 0.9 1.1/4x1x1.1/4 358T3012010012 1.75 1.69 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 24 32 48 1.0 1.1 1-1/2,x1/2x1.1/4 35R13014004012 1.81 1.56 1.88 1-1/2x112x1-1/2 35R13014004014 1.94 1.66 1.94 12 24 32 40 1.2 1-1/2x314 35813014006 1.52 1,52 1.75 16 1.1 1-112x3/4x1-1/4 35RT3014006012 7 94 1,66 188 20 1.1 1-1/2x3/4x1-1/2 358T3014006014 1,94 1,75 1,94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 20 24 40 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 0.8 1-1/2x1x3735RT3014010006 1.0 1.44 ' 1.751632 16 32 0.9 1-1/2xlx1 35R13014010010 1.65 1.50 1.80 1.0 1-1/2x1x1-1/4 35R13014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 358T3014010014 1,94 1,80 1.94 12 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.88 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014612006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35813014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1.1/4 35RT3014012012 182 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 358T3014012014 1.94 1.88 1.94 14 28 1.4 2x 1/2 35RT3020004 1.49 1.49 ' 1.88 10 10 20 1,5 2x3/4 35813020006 1.60 1.60 1.97 20 1.6 2 x I - 35RT3020010 1.73 1.73 2.02 2.25 8 16 1,7 2x 1 x2 35813020010020 2.25 2.02 S 16 1.9 2x1-114 35RT3020012 190 1.90 2.10 8 16 1.9 2x1-1/4x2 35813020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 358T3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2x 1-1/2 x 3/4 35RT3020014006 160 152 197 10 20 14 2x1-1/2x1 358T3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 358T3020014012 1,90 1.82 2.10 2.16 8 16 1.7 1.8 2x1112x1-1/2 35813020014014 2.02 1.94 8 16 F] c®uS Fig. 35RT3 - Reducing Tee LISTED Fig. 35873 - Bull Head Tee Size in Part Number A , B C Packig Weight lb Inner Master 3/4 x 35613006010 1.45 1.45 1.37 30 .0 0.6 1x1114 356T3010012 167 167 158 2 40 09 1 x 1-1/2 35613010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 358T3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35B13012014 188 1.88 1.82 15 30 1.3 1-1/4 x2 35613012020 2.10 2.10 1.90 10 20 20 1,6 - 1-1/2x1-1/4x2 35813014012020 2.16 2.10 2,02 10 1,8 1-1/2x2 35BT3014020 2.16 2.18 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL 9 TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 9 ww.smiLhcooperom 112 c®us PMVED Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 1.75 100 200 0.2 1 35CP3010 60 120 0.4 1-174 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 2 35CP3020 2.62 15 9 1.2 2-1/2 35CP3024 3.00 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35H93010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1.1/4 35H83014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0,6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 3HB3020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 353P3004 0.94 600 1200 0.07 35SP3006 1.12 350 700 0.1 1 355P3010 1.25 200 400 0.1 1-1/4 353P3012 •' 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 ' 45 90 1 0.6 -iN INNER \1 =m iI A Z. NO , - - ~ M~A-~Ll Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner I Master lx 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 169 60 120 0.4 1-1/4 x3/4 35R03012006 2.06 40 90 0.6 12 xT(not hex) 35RC3020010 1 2,81 20 40 - 1.0 Fig. 35HB3 - Hex Bushing Fig. 35U 3- Union with Brass Seat Size in 1 Part Number ______________ 35U3010 A in 2,19 Packing Weight lb 1.0 inner 20 Master 40 1-1/4 35U3012 20 15 30 1.2 1-1/2 36U3014 2.62 10 20 1.7 2 35U3020 1 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL 9 TOLL FREE 1-800.766-0076 0 FAX (323) 8904456 9 www.smithcooper.com ®s ? Fig. 35X 3— Cross LISTED Size Part Number A in Packing Weight lb inner Master 1 35X 3010 1.50 20 40 0.9 1-114 35X 3012 175 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 225 6 12 28 A Fig. 35RX3 - Reducing Cross Size In J Part Number r A in B in Packing . J Weight lb Inner I Master j 1-1/4 x1 35RX3012010 1.67 158 15 30 1.2 1-1/2x1 35RX3014010 180 1.65 12 8 24 1.4 2 x 1 35RX3020010 2.02 - 1.73 16 20 Fig. 35C 3— Cap Size in Part Number A in Packing Weight lb inner Master 1/2 350 3004 0,87 300 600 0.1 3/4 35C 3006 0.97 200 400 - 0.1 - 1 3503010 1.16 110 220 0.2 174 35C 3012 1.28 70 140 0.4 1-1/2 3503014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0,8 2-1/2 350 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Size in Part Number A in Packing Weight I lb I inner -[Master 3/8 35B03003 0.75 100 200 0.3 1/2 35B03004 0.75 80 ' 160 0.5 SMITH-COOPER INTE RNATIOIN ALI • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 0 wwcsmirhcoopercom 114 Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the lace of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock, (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for meximumpullout in purlin steel. 1, Insert the appropriate not driver into a 3/8" or 1/2"portable drill 2. Insert the SAMMYS into the #145W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3, When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4", 3/8", MW, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximum pullout in purlin steel. z -1L7A1 -- [INSTALLATION STEPS INTO CONCRETE: 1 Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin Insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 6. The concrete screw is ready to receive 1/4", 3/8 , 1/2", or metric all thread rod or bolt stock. (#14SWrd nut driver used with 1/2"screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in Impact mode doing so will destroy the pullout factor of the screw. [INSTALLATION STEPS - 1jj% INTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilting has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion, When the nut driver spins free on the SWC screw, installation is complete, Stop and remove drill, The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode doing so will destroy the pullout factor of the fastener. PEM, HUT DRYER ZYSTW, The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into coitact with the material you are installing Into, continue trifling until nut driver spins free. Installation 13 then complete. Warranty requires the use of the appropriate nut driver for installations, Fig. 25 - Surge Restrainer C® US USTED Size Range One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function Designed to be used in conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer Is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as Indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4,1 and 9,2.3,4..4 Can be used to restrain either steel pipe or CPVO plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Paterfl #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 9 800.786.5266 • FAX: 951.737.0330 Size Range Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note— Available in Electro•Gaivanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSI-IPO Approved c 1k us usrw Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). taints Catalog approved by the State of Ca.ornia çn.ice of Statewide Health Plan ning and PmenI(QHPPLF.oradditionaHoaØ spacing and plgcement inform.ation re..ating to OSHPD projects. pleas .er to tothe TOLCO Seismic. Restraint Systems Guidelines Finish Electro Galvanized Note Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F -- Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750° F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish D OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. •CORONA, CA 92879 • PH: 951.137.5599 • FAA: 951.731.0330 CUSTOMER SERVICE . 800.186,5266 wwwwlco,cwa Fig. 200-21/ to 200-8 Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Flu, B3170NF) @TO= Fig. 200 Fig, 2005 Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Une Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes, Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily 44 installed around pipe, For hanger with non-captured nut order Fig. 2008. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed, Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig, 2001 to 200-2 Factory Mutual Engineering Approved (FM) 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-I 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58. Type 10. Maximum Temperature: 650°F (3439C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FMDS2-0. Fig. 200C Fig. 200F flik4. Part 200.1 /2 Pipe 1/2" Size (15) Rod Size /8"-16 A !I. 31/8° (79.4) 2/8" B I lifflil (66.7) .Iti)Yi aTi ii. 11 (5.0) 200-/4 3/4' (20) /8' 16 31/8' (794) 21/2 (635) 11 (50) 200-1 1" (25) /8"-16 33/9" (85.7) 2/8" (66.7) 12 (5.5) 20011/4 11/4" (32) /8"-16 33/4" (94.0) 2I" (73.0) 13 (5.9) 200.11/2 11/2" (40) I8"-16 37/9" (98.4) 2/8" (73.0) 14 (6.4) 200-2 (50) /a"-16 41/2" (1143) (76.3) 15 (6.9) 200-21/2 21/2" (65) /811-16 55/8" (142.9( 41/8" (104.7) 27 (12.3) 200-3 3" (75) /a"-16 57/9" (149.1) 4" (101,6) 29 (13.3 200.31/2 31/2" (90) /8"-16 73/9" (187.3) 51/4' (133.3) 34 (15.6) 200-4 4" (100) /8"-16 73I" (187.3) 5" )127.0 35 (16.0) 200-5 5" (125) 1/2",.13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 112"_13 101/8" (257.2) 614" (171.4) 73 (33.4) 200-8 8" 1 (200) 1/2"..13 131/9" (333.4) 8i4" (222.2) 136 (62.3) COOPER B-Line y Fig. 200-1/2, 200-/4 Fig. 200-21/2 to 200-8 Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range; Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pro-Galvanized to G90 specifications Function; For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation, Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease Installation for all pipe 44 types and protect CPVC plastic pipe from abrasion, Captured design keeps adjusting nut from separating with hanger. Hanger is easily Installed around pipe, (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely In hanger before installation. Adjusting nut is easily removed. Approvals; Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) 2001 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved /4" (20mm) thru 8" (200mm). Conforms to Federal Specifications WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10, Maximum Temperature; 650"F (3439C) Finish: Pre-Galvanized, Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. 200M8-1/2 . Size 1/2" (15) Rod Size • M8 A I 31/s" (79.4) 2I8" B (66.7) jJy1 ii Approx. . 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2I8" (66.7) 11 (5,0) 200M8-3/4 3/4" (20) MB 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M8-1 1" (25) MB 3/8' (85.7) 2I8" (66,7) 12 (5.5) 200M1 -1 1" (25) M10 3%" (857) 2I8" (66.7) 12 (5.5) 200M8-11/4 11/4' (32) MB 33/4" (94.0) 2/8" (73.0) 13 (59) 200M10-11/4 11/4" (32) M10 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2' (40) MB 37/8" (98.4) 2I8" (73.0) 14 (6.4) 200M10-11/2 1/" (40) MiD 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 (50) MB 41/2" (114,3) (76.3) 15 (6.9) 200M10-2 2' (50) MiD 41/2' (114,3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) MiD 5/8' (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) MiD 5/8" (149.1) 4' (101,6) 29 (13.3) 200M-3112 31/2' (90) MiD 73/8' (1873) 51/4" (133,3) 34 (15.6) 200M-4 4 (ioo) MiD 73/8' (187.3) 5" (127.0) 35 06.01 200M-5 (125) M12 91/8" (231.8) 61/4 (158,7) 66 (30.2) 200M-6 (150) M12 101/8 ' (257.2) 6/4" (171,4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333,4) 8/4" (222.2) 136 (623) AU dimensions in charts and on drawings are In inches, Dimensions shown in parentheses are in millimeters unless otherwise specified. PP- 00 COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size, Used extensively to support trapeze Installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with 3/'16 or 1/2.13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL.) and Canada" (cUL). Conforms to Federal Specification WWH-171E & A.A1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended, L Li 200H-2-3/8 Pipe 1 2" Size (50) Rod Size 3/8"-16 A I. 4/16 (115,9) H. 3/32 B . •Y1 I I (fl3) TM11 ): (81.7) 48 ' (21.8) 200H-2-1/2 2" (50) 1/2 .13 423/32' (119.8) 3/8" (85.7) 45 (20.4) 200H-2112-318 21/2" (65) /8"-16 5f16" (134.9) 323/32" (94.4) 59 (26.7) 200H-2112-112 21/2' (65) 1/2 .13 515/32" (138.9) 3I8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4" (146,0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2".13 5/" (148,1) 331/32" (100,8) 60 (27.2) 200H-4-318 4" (100) /11-16 6/8" (174.6) 4I1" (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2 .13 71/32" (178.6) 4 /32" (1116.7) 73 (331) ° Select trapeze pipe size based on section modulus required for span of trapeze per information provided In NFPA 13. All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13, For 6° (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches, Dimensions shown In parentheses are in millimeters unless otherwise specified. COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions. LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1 -quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSFIEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPI, LubeRt® are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Mastet®, RowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 0 SAN DIEGO SEAL, INC. 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858278-2950 E-MAIL: salessandiegoseai. corn • VISIT US AT: www.sandiegoseal.com PTFE Thread Sealant Tapes Made in the USA ir thread sealant tape breaks clean without shredding warping, identifying it as a product that can be trusted perform reliably when the job is completed and the assure is on. EM Standard Grade - £'• UA444, 4 Our standard grade PTFE Thread Sealant Tape is for those applications that do not require the sealing properties of a premium grade thread sealant. This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, . / economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. is effective and efficient so you can use less tape. Tears cleanly. ..seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI, Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique i rT----' blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or L defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Installation Specifications Recommended Use Make sure that the threads are free Water Air from burs and other debris. Apply Appearance: Dense, paste-like consistency, Refrigerants Natural Gas Pipef it® liberally to the male pipe off white in color. Mild caustics Steam threads. Make sure that the thread Kerosene LP Gases sealant is brushed into the "root" of Packaging: Acids Gasoline the threads. Do not wipe off excess 16 oz. brush in cap 32 Diesel Fuel Ammonia material until fitting has been "made 32 oz. BIC on" to the pipe thread. The threading 1 gi. Use for threaded connections on action of the fitting to the pipe will 55g. steel, aluminum, brass, PVC, CPVC allow the proper amount of sealant and ABS. Operating temperature to remain in the connection. Wipe off CAUTION: See MSDS for first ranges -50 f to 500 f. excess sealant. Pipef it® will not dry aid instructions. Wash hands thoroughly after each use. out under normal conditions. Never use dope and tape together. Keep See Material Safety Data FBC/;-.covered when not in use to avoid Sheet for additional safety and contamination. Some settling of disposal information at www.fppi.com *FBC System Compatible indicates the product may occur. Occasional this product has been tested by stirring may be necessary. Two year Lubrizol Advanced Materials and shelf life. is monitored on an on going basis to assure chemical compatibility with Disclaimer FlowGuard Gold®, BlazeMaster®, and DO NOT ALTER THE CONSISTENCY Corzan® pipe and fittings. OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact 3198 LiONSHEAD AVE occurs, flush with water for 5 minutes. CARLSBAD, CA 92010 TEL+ 1 760 599-1168 , If discomfort persists get medical + 1 800 344-1822 attention. F(+1800344-3775 -U © 2012 Fire Protection Products, Inc. FPPI5, LubeRtO are registered trademarks of Fire Protection Products, Inc. registered trademarks of Noveon IP Holdings Co LA FBC, BIazeMaster, FlowGuard Golde and Co,zane are rp. U.S.A. Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it Ideal for use in high speed threading applications. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. © 2013 Fire Protection Products, Inc. FPPI5, ThreadRO are registered trademarks of Firs Protection Products, Inc. wu CA MACI IN Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBC' SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Golds, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAO, CA 92010 TEL + 1 760 599-1168 + 1800 344-1822 FAX + 1 800 44-3775 Installation ThreadFit0 can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling Information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 191, (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician Immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product Is registered with CHEMTREC, a 24-hour emergency hotilne. They may be reached at 1 800 424-9300. Victaulic® FireLockTM Fittings /ac—t-n—ulicr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 - 8/DN32 - DN200 Maximum Working Pressure Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials Carbon steel 2.0 CERTIFICATION/LISTINGS unn EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: (specify choice) Orange coating. O Red coating (standard for EMEA-1 and Asia Pacific). Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 10.03 01539 Rev 0 updated 10/2021 © 2021 Victaulic company. All rights reserved. 1 Licctaullfcr victaulic.com 4.0 DIMENSIONS ICtoE.1 k..- I to C 0 C to E to No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 450 Elbow Straight Tee Cap_________ Approximate Approximate Approximate Approximate Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 1¼ 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 1 ½ 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 - - 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 1 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 - - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - - 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com \/6taulIC victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee Nominal Outside No. 001 No. 003 Size Diameter 900 Elbow 450 Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 11/4 1.660 - - - - DN32 42.4 - - - - 1½ 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 0N80 - 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 - 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 0N125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 1 1. 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic Company. All rights reserved, victaulic.com Aictsulic victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZ'" couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLock' No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic® FireLock°M Rigid Coupling Style 009N 10.02: VictauliClEt FireLock°M Rigid coupling Style 005H with Vic:Plus°M Gasket System 29.01: Victaulic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design in intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installutionrassembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be muds to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available is POE format on our websife at www.oictaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. andIor other countries. 10.03 01539 Rev 0 Updated 10/2021 © 2021 Victaulic company. All rights reserved. victaulic.com Aictaulicf