Loading...
HomeMy WebLinkAbout3415 VIA MONTEBELLO; ; FPC2024-0130; Permit(hty of PERM IT REPORT Carlsbad Print Date: 02/03/2025 Permit No: FPC2024-0130 Job Address: 3415 VIA MONTEBELLO, CARLSBAD, CA 92009-8487 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2230531300 Track #: Applied: 09/27/2024 Valuation: $860,100.00 Lot #: Issued: 10/16/2024 Occupancy Group: Project #: Finaled Close Out: 02/03/2025 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Arroyo, Deisi Plan Check#: Valdes, Rebecca Project Title: Description: REl -ADDING ANEW FIRE ALARM SYSTEM (50 DEVICES) Applicant: FPContractor: STANDARD ELECTRONICS ACCENT ELECTRONICS JESUS LEDEZMA 613 W MAIN ST 9340 STEVENS RD EL CAJON, CA 92020-3323 SANTEE, CA 92071-2810 (619) 596-9950 (619) 596-9950 FEE AMOUNT FIRE New Alarm System $1,646.00 Total Fees: $1,646.00 Total Payments To Date: $1,646.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov (4:1i Standa Ph: (619) 596-9950 Fax: (619) 596-8850 613W. Main St. El Cajon, CA 92020 o:cs C7, do UC. #590876 BSISACO #AC01903 Electr UL Installer #S3570-1 StandardElecfronics.t SUBMITTAL SHEET September 16, 2024 PROJECT: REI Carlsbad FA - 3339 ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET . Addressable Fire Alarm Control Panel with Communicator I I SFM#7165-0075:0500 ES-200X Fire-Lite Remote Annunciator, 80-character Backlit Display 2 1 SFM#7120-0075 :02 11 ANN-80 Fire-Lite Dual Path Internet and 5G LTE-M Fire Communicator 3 1 SFM#7300-1402:0503 TG-7FE Telguard 4 1 Fire Alarm Document Storage Box SSU00690 Space Age 5 1 Battery Enclosure for ES 17-12 Batteries SSUOOSOS Space Age 6 2 12 VOLT 18 AH Sealed Lead Acid Battery ES17-12 MK Battery Addressable Photoelectric Smoke Detector, White 7 1 SFM# 7272-0075:0502 5D365 Fire-Lite Intelligent Duct Smoke Detector, Includes 5D365R Detector 8 7 SFM#3242-0075:0508 D365PL Fire-Lite 3" Sampling Tube for DNR (NO DATA SHEET) DST-3 FCI Key Activated Remote Test Station 10 SFM# 7300-1653:0212 RTS 151 KEY System Sensor Addressable Pull Station 11 1 SFM# 7150-0075:0184 BG-I2LX Fire-Lite Addressable Monitor Module 12 3 SFM# 7300-0075:0185 MMF-30 1 Fire-Lite Addressable Output Relay Module 13 7 SFM# 7300-0075:0185 CRF-300 Fire-Lite Ceiling Strobe, 12/24volt, red, multicandela 14 SFM#7300-1653:0525 SCRLED System Sensor Wall Strobe, 12/24volt, red, multicandela 15 9 SFM#7300- 1653:0525 SRLED System Sensor Ceiling Horn/Strobe 12/24volt, red, multicandela 16 14 SFM#7135-1653:0526 PC2RLED System Sensor Wall Horn/Strobe 12/24volt, red, multicandela 17 7 SFM#7135-1653:0526 P2RLED System Sensor Wall, Outdoor Strobe, 12/24volt, red, multicandela 18 1 SFM#7125-1653:0I 87 SRX System Sensor 19 1.5K 2 conductor, 16 AWG, Unshielded, Plenum Jacketed 162FP WCW Ph (619) 596-9950 Standa Fax: (619)596-8850 613W. Main St. I, El Cajon, CA 92020 C7, C1O UC. #590876 IUL o cs ESISACO #AC01903 Installer #S3570-1 StandardElectronics.us SUBMITTAL SHEET September 16, 2024 PROJECT: REI Carlsbad FA - 3339 ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 20 1.5K 2 conductor, 12 AWG, Unshielded, Plenum Jacketed I22FP WCW 21 1 0.3K 2 conductor, 16 AWG, Unshielded, Jacketed, Underground 142+162 ADL DF-60957:D ES-200X Series FlreuTeALarms Intelligent Addressable by Honeywell Fire Alarm Control Panels Addressable Fire Alarm Control Panels ltt:1 The ES-200X, ES-200XC, ES-200X1, and ES-200XP are the latest intelligent addressable Fire Alarm Control Panel (FACP) from Fire•Lite Alarms and is a direct replacement for the MS-9200UDLS. The ES- 200X support up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the ES-200X Series programs just like Fire'Lite's other addressable products, yet fits into applications previously served only by conventional panels. The ES-200X and ES-200XC feature a pre-installed IPOTS-COM, a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicators inter- net monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using an HW-TG7F Series Communicators or the CLSS Pathway. The ES-200XP features an integrated CLSS Pathway Pro Communi- cator, a dual-SIM (AT&T/ Verizon) 5G LTE-M Communicator with optional IP connection. The CLSS Pathway Pro transmits system sta- tus (alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-Ml networks, serving as a bridge between the fire system and the CLSS Cloud. The IP communicator's Internet monitoring capability sends alarm signals over the Internet, meeting requirements for backup communication. As an integrated communicator, the CLSS Pathway Pro, typically, can transmit data faster than dial capture meth- ods. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator (ES-200X and EX-200XC only). The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system voltages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabi- net. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmit- ter (4XTMF). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator (ES-200X and EX-200XC only) Optional Cellular Central Station Communicators over AlarmNet® (ES-200X and EX-200XC only) Integrated CLSS Pathway Pro Communicator; dual SIM AT&TNeri- zon networks with LTE-CAT-M1 5G technology (EX-200XP only) Cloud monitoring using Honeywell's Connected Life Safety Ser- vices (CLSS) Cloud solutions software (EX-200XP only) Automated activation of the ECC-50/100 Emergency Command Center ECC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable, Class A or Class B NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterf low selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumulation is excessive One-person audible or silent walktest with walktest log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via address- able modules or remote annunciator Upload/Download of program and data via USB with optional FS-Tools Programming Utility SLC (DCL) COMMUNICATION LOOP Supports LiteSpeedTm and CLIP protocols SLC (DCL) operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC (DCL) loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressable detectors and 99 modules) OF-60957:1) • 3/27/2023 - Page 1 of 4 Compatible with Fire'Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) Four independently programmable output circuits. Circuits can be configured for Class A or Class B wiring Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main cir- cuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Off line programming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS Fire Alarm (red) • CO Alarm (yellow) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) • Communication (yellow) Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad • Acknowledge Alarm Silence • Drill (Manual Evacuate) Four (4) programmabigfunction keys • Reset (lamp test) PRODUCJJNE11ORMATION ES-200X5ddressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. ES-200XC: Addressable Fire Alarm Control Panel with one DCL loop. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, dress panel, backbox with door, plastic bag containing screws, cables, key, etc. ES-200X1: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, dress panel, backbox with door, plastic bag containing screws, cables, key, etc. ES-200XP: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed CLSS Pathway Pro communicator, chassis with transformer, dress panel, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC computer. Available for download at www.firelite.com. lPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) (ES-200X and EX-200XC only) HW-AV-LTE-M: Optional CLSS Pathway HW-TG7FS-A/HW-TG7FS-V: CLSS-Enabled 5G /LTE-M Commercial Fire Alarm Communicators for AT&T® and Verizon® HW-TG7FE-A/HW-TG7FE-V: CLSS-Enabled 5G/LTE-M Dual Path Commercial Fire Alarm Communicators for AT&T and Verizon HW-TG7FP-A/HW-TG7FP-A: CLSS-Enabled 5G/LTE-M Sole Path Commercial Fire Alarm Communicators for AT&T and Verizon DP-ES-R: Optional dress panel for the. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. NOTE: CHG-120F or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trou- ble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. ANN-100: Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. For use in FM applications only. ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See OF- 6024 1.) ANN-RILED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365(A): Addressable low-profile photoelectric smoke detector. Lite- Speed only. SD365(A)-IV: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T(A): Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T(A)-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R(A): Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R(A)-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. LiteSpeed and CLIP mode. SD365C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection, LiteSpeed only. SD365CO-IV: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. Ivory. LiteSpeed and CLIP mode. Page 2 of 4— DF-609570 • 3/27/2023 H365(A): Low-profile 135°F fixed thermal sensor. LiteSpeed only. H365(A)-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R(A): Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R(A)-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT(A): Low-profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT(A)-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. LiteSpeed and CLIP mode. D365PL: Low-flow non-relay duct-detector housing; includes SD365R. Legacy Devices CP355(A): Addressable low-profile ionization smoke detector. SD355(A): Addressable low-profile photoelectric smoke detector. SD355T(A): Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R(A): Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355(A): Fast-response, low-profile heat detector. H355R(A): Fast-response, low-profile heat detector with rate-of-rise option. H355HT(A): Fast-response, low-profile heat detector that activates at 1900F1881C. AD355(A): Low-profile, intelligent, "Adapt' multi-sensor detector (13350LP base included). B200S(A)(-WH)(-IV): Programmable, addressable sounder base. B200SR(A)(-WH)(-IV): Addressable sounder base. B200S-LF(-WH)(-IV): Programmable, addressable sounder base, low- frequency. B200SR-LF(-WH)(-IV): Addressable sounder base, low-frequency. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL(A): InnovairFIex low-flow non-relay duct-detector housing; includes 5D355R. DNR(A): InnovairFiex low-flow non-relay duct-detector housing. (Order 5D355R(A)/SD365R(A) separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R(A)/5D365R(A) sepa- rately.) Addressable Modules MMF-300(A): Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0° (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A IDC. MDF-300(A): Dual Monitor Module. Same as MMF-300(A) except it provides two Class B-only IDCs. MMF-301(A): Miniature version of MMF-300(A). Excludes LED and Class A option. Connects with wire pigtails. May mount in device back- box. IvIMF-302(A): Similar to MMF-300(A). Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300(A): Addressable Control Module for one Class B or Class A zone of supervised polarized Notification Appliances. Mounts directly to a 4.0° (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300(A): Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0° (10.16 cm.) box, surface mount using the SMBSOO. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300(A): This module isolates the SLC loop from short circuit condi- tions (required for Class A or Class X operation). ISO-6(A): Six-fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chas- sis in a BB-6F cabinet. SMB500: Used to mount all modules except the MMF-301(A) and M301 (A). MMF-300-10(A): Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS- 6 chassis in a BB-6F cabinet. MMF-302-6(A): Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6(A): Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6(A): Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE(A): LiteSpeed Wireless Gateway W-SD355(A): LiteSpeed intelligent, wireless photo detector. W-H355R(A): LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T(A): intelligent wireless photo/heat detector. W-H355(A): LiteSpeed intelligent wireless fixed-temperature (1350) heat detector. W-MMF(A): LiteSpeed Intelligent wireless monitor module. W-CRF(A): LiteSpeed Intelligent wireless relay module. W-BG12LX(A): LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-200X, see the following data sheets (document numbers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMFICRF Series (DF-52 130), CP355 (DF-52383), H355 Series (DF- 52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), S0355/ 5D355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, 5D300(7)/SD350(7) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP proto- col. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the MMF-300(A), MDF-300(A), MMF-301(A), and CMF-300(A) module circuits. The 3.9k ohm assembly supervises the MMF-302(A) module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC (DCL) wiring be twisted-pair to minimize the effects of electrical inter- ference. Refer to the panel manual for wiring details. DF-60957:D • 3/27/2023— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits...................................................1 Addressable device capacity.....................................................198 Programmable software zones....................................................99 Annunciators................................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Non-power-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capac- ity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH batter- ies.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Class B or Class A. Special Application power. Power-limited, supervised circuitry. Maximum signaling current per cir- cuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Class B NAC; system capable of 1.9 K2 - 22 k2 ELR range. Refer to the Fire -Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A © 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring (TR-CE): 22.00' (55.88 cm.) high x 19.65' (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C * 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F. NFPA Standards The ES-200X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-200X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. ES-200X, ES-200XC, ES-200X1 UL: S624 FM approved CSFM: 7165-0075:0500 FDNY: COA #2021-TMCOAP-009618-AMD ES-200XP ETL: 5017286 CSFM: 7165-0075:0511 lnnovalrFlexlM and LlteSpeedTM are trademarks and AlarmNet®, Fire-Llte® Alarms, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. AT&T® is a registered trademark of the AT&T Properties, L.P.Verizon® is a registered trademark of Verizon Trademark Services LLC. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2023 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ISO 9001 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. b I MMuf1WT QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX:(877) 699-4105. Country of Origin: USA www.firelite.com Page 4 of 4— DF-60957:1) • 3/27/2023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-0075:0500 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC. One ire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa 203484ft105 Email: lisa.brant@honrl.com DESIGN: Models ES-50X, ES-200X, and *ES..locjo)( Addressable Fire Alarm Control Units. Automatic, manual, waterflow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The ES-50X is a compact version of the ES-200X. The ES-50X has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The ES-200X has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.oamps with Model PWRMOD24. *The ES-1000X has 954 addressable device capability and 4 Notification Appliance Circuits with 8.0 amps total 24VDC output in Alarm. The Model IPOTS-COM provides Phone and IP communication. *The optional suffix "I" indicates the depopulation of the [POTS-COM in the control unit. *The CELL- MOD or CELL-CAB-FL has the option to be configured by an ES-50X or ES-200X compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Models ES-50X, ES-200X, and *5..yJ)( system components are as follows: IPOTS-COM\tPOTS and lP Communicator 4XTMF Transmitter Module ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Interface Module ANN-RLY Form-C Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module Page 1 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE *Models ES-50X and ES-200X system components are as follows: CELL-MOD GSM Communicator CELL-CAB-FL\tGSM Communicator DP-ES-R Dress Panel Model ES-200X system components are as follows: PWRMOD24\tNAC Power Expander Module *Model ES-1 000X system components are as follows: SLC-3LS SLC Loop Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. *Models complies with the applicable requirements in UL 864, 10th Edition. NOTES: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. *Rev 07-14-23 DAL Page 2 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 3 of 3 ANN-80 80-Character Serial LCD Annunciator The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechanically locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4" square electrical box Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the panel Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators AC Power Alarm Trouble DF-52417:D • B-go (a HreLITeALarms by Honeywell Annunciators Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient temperature: 32°F to 120°F (0°C to 49°C) Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep For use indoors in a dry location All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. DF-52417:1) • 3/15/2018 - Page 1 of 2 WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 -2.08 mm2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:0211 MEA: 442-06-E Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. Iso 9001 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. = b I U .1 M0rlN; & MNtIFAC11fi1N QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. Country of Origin: USA www.firelite.com Page 2 of 2— DF-52417:1) • 3/15/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7120-0075:0211 CATEGORY: 7120 - ANNUNCIATORS LISTEE: FIRE-LITE ALARM NC. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Ljz (203) 484-6105 (203) 484-7309 ljisa.br@honeyweII.com DESIGN: Model ANN-80 and *ANN..80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. NOTES: *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational Ar requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Listing Expires: 06/3012025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 )OSE THE COMMUNICATO521AT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. HRE PRODUCTS I COMMUNICATION PATHWAYS INPUT POWER OPTIONS HARDWARE OPTIONS MODEL CELLULAR INTERNET J TELCO PANEL DC (12/24V) PLUG-IN AC UPGRADE BOARD TG-PEM TG-7FE -. TG-7FP TG-7FS - 24V needs TG-PE? - TG-7UBL INTERNET ó COMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FE offers two pathways to reliably transmit signals: a wired LAN connection to the Internet and 5G LTE-M cellular. It operates on panel power or via plug-in transformer. PRODUCT FEATURES I Dual communication paths - If the Internet connection is interrupted or the LAN goes down, always-on 5G cellular will immediately step in. P Powers directly from the fire panel's 12V/24V auxiliary power supply or via plug-in transformer (included). P Uses LTE-M bands for 4G and 5G network compatibility, better in-building penetration, and longest product life. I- Interfaces with panel over a single DACT connection for universal compatibility (use TG-PEM accessory when panel has no DACT). I Telguard communicators are compatible with more alarm formats than any other brand. The signal will reliably get to the central station. The world is changing. Copper POTS lines are disappearing, and calls are delivered over the Internet. This is a perfect example of where the TG-7FE steps in. Eliminate all Telco lines and run an Ethernet cable from the TG-7FE to the premises LAN for alarm signal delivery. And, to be sure signals get through to the central station you choose, the TG-7FE instantly falls over to reliable cellular service any time it's needed. Telguard puts nearly four decades of alarm communications expertise into every UL Listed communicator. You stay in control, with highly configurable options that meet your needs and the requirements of your AHJ. For the most current product specifications and UL Listings visit telguard.com/tg-7fe. In Canada, cellular data may be carried by Rogers, Bell. Telus or SaskTel 800.229.2326 1 3225 Cumberland Blvd SE • Suite 300' Atlanta, GA 30339 • USA I telguard.com ©2021 Telguard I Telguard and the Telguard Logo are registered trademarks of Telular Corporation. I Telular is a business Unit of AMETEK, Inc. All Rights Reserved. AMETEK 02021R,vO 9/17/24,4:22 PM LicenseBMLLINGLISTNEW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1402:0503 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP. 025 Cumberland Blvd, NE, Suite 300, Atlanta, GA, 30339 Contact: StewarVSean (800) 229-2326 (678) 945-1651 Email: DESIGN: Model TG-7FE Digital Cellular Radio Alarm Transmission Device. Models are suffixed with -A for AT&T networks and -V for Verizon networks. Product is used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. The control unit and TG-7FE communicator must be installed in the same room. Intended for indoor and dry locations. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 120 VAC; 12or24VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as digital cellular radio alarm tranmission device for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: Burglary and other non-fire functions were not examined. 9-22-21 VWW This listing is based upon technical data submitted by the applicant OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational 7 requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/06/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division 1/2 9/17/24,4:22 PM LicenseBMLLINGLISTNEW Page 1 of 1 2/2 Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 722013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). Space Age Electronics, Inc. MOO NFPA T PANY 800.486.1723 Toll Free ade 508.485.0966 Local In\U.S.A. 508.485.4740 Fax Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! JESPACEAGE ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector POpO6Y Info,m,tlon Minmorn, ReqoIrd D000n,ontotlo,, (SIG-FUN) CCndApproval, 16.1 SyGen, In01oIJetion Contractor: 0I. 0.00*II000060. 0,00.0000Ob*INFR,O,S00dMCh 4S.qc.&,p.0th00fl1.,.cjn,0c4cc.ece,ec.c..fen, 16.5 Acdhority Having J0iedioyion: It .0*0.0 C CCItt,, .0*11*0.1*0 0 Cc *,O*0Cl0Id*t1*kfl.lSn,.**l*,.*p.lC, NFPfl*0tt,fldh*001 C*0*MI*0**00000001CO*001N/*0It.*t,IO5.Slefl 01.000. I00010.C.d/..0.dd,*fl,00.flh.N,N0fl,N...t76 C.,flhNN 100 11 00010.S.fl*at.NONn,N10.n,n,1*.. Eqwpmoet Iflf*0rnaticn 1.000.*1*ltfll1* 0*0*0*0 000*0011*0 1010644 Rn,. I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED "\ S5U00690 Custom screening with your Logo EA03I 5 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0584 LT10641 Rev.A 2/2 Mini Battery Cabinet The MBC "BATTERY CABINET" is designed for the profes- sional installation of systems requiring battery storage and meets the requirement of NFPA 72 (1-5.2.9) stand-by battery storage for battery backup. The MBC allows for easy access and maintenance of the bat- teries while also assisting against unnecessary power drain, interference or degeneration of the battery. The unit can be mounted securely to a wall, preventing mechanical injury or damage to other equipment. The door of I lifts away for worry free wiring and battery change-out. Standard Features: 16 Gauge (.062 thk.) cold rolled steel White 2" lettering "BATTERY CABINET" Green ground screw with threaded insert Formed lift-a-way hinge Red or Black textured finish CAT 30 keyed door lock Dimensions: 17" wide x 8" high x 4" deep Six 1/2" and 3/4" EMT conduit knockouts located on both sides, top and back NFPA 72 National Electric Code NFPA Made In U.S.A. _..-1 0 0 ISO 9001 N AL RG1E1ED \ IV ADA Space Age Electronics, Inc. www.sae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0247 LT1 0247 Rev.B 1/2 No Excuses, Just Solutions! Removable formed lift-a-way hinge SPACE AGE ELECTRONICS, INC. Specifications: The MBC Mini Battery Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and finished with a durable red or black textured, heat-resistant baked-on enamel finish. The front cover is engi- neered with a removable formed lift-a-way hinge, displays "BATTERY CABINET" in 2" white screened lettering and includes a high security CAT 30 keyed door lock. The unit comes with a green ground screw with threaded insert. Overall dimensions measure 17" wide by 8" high by 4" deep. Six 1/2" and 3/4" EMT conduit knockouts are located on both sides, top and back. The battery cabinet meets NFPA 72 National Electric Code requirements. Batteries not included. Ordering Information: Part # Description SSU00505 MBC Mini Battery Cabinet - Red SSU00506 MBC Mini Battery Cabinet - Black Space Age Electronics, Inc. Www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0247 LT10247 Rev.B 2/2 ($1712 SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate (0.9A to 10.50V) 18Ah 10 hour rate ( 1.8A to 10.50V) 17.1Ah 5 hour rate (3.06A to 10.20V) 15.3Ah 1C (18Ato9.60V) 8.1Ah 3C (54A to 9.60V) 6.3Ah Weight Approx. 13.82Lbs. (6.28kg) Internal Resistance (at 1KHz) 10 mQ Maximum Discharge Current for 30 seconds: 360A Maximum Discharge Current for 5 seconds : 720A Operating Temperature Range Charge 0°C (32°F ) to 40°C (104°F) Discharge -15°C (5°F) to 50°C (122°F) Storage -15°C ( 5°F ) to 40°C (104°F) Charge Retention (shelf life) at 20°C ( 68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use: Charging Voltage 14.4 to 15.OV Maximum Charging Current : 5.4A Standby Use: Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use : 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use: 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) Maintenance-Free Rechargeable Sealed Lead-Acid Battery DIMENSIONS mm(inch) 12 F2 F3 (FASTON TAB NO. 260) (M5 Boils) 11131 El 1814(7.134 - a--- ZrW 16 - CE fl 6807.12 91 V 120.1$10521116 —p— Pb Discharge Time VS. Discharge Current (20C) Terminal F2orF3 1 2 45618 10 1060 2 46810 20 I— 60)6100. —6 1— hoor. —.1 Discharge Time MK Battery V 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com SD365 Series Addressable Photoelectric Smoke Detectors FireLiTeAtarms by Honeywell . 1. Ii3.*1.I [I 'I.'A [.i3. The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke detectors are designed for both perfor- mance and aesthetics, and are direct replacements for the SD355 Series. A new modem, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The 5D365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with LiteSpeedTM and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the Fire•Lite panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (LiteSpeed systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation SD365 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Class "B" wiring only. When using relay or sounder bases, consult the 1300(A) installation sheet 156-3626 for device limitations between isolator modules and isola- tor bases. Construction These detectors are constructed of fire-resistant plastic. The 5D365 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each 5D365 Series detector uses one of the panel's addresses (total limit is panel dependent) on the Fire•Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an Fire-Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DF-61010:C • 5/28/2020 - Page 1 of 3 Product Line Ifo1mation NOTE: "-IV" suffijpdites CLIP and LiteSpeed device. NOTE: Z"Ix indicates Canadian version. SD365, low-profile intelligent photoelectric sensor, LiteSpeed only SD365A: Same as SD365 but with ULC listing SD365-IV: Ivory, low-profile intelligent photoelectric sensor SD365A-IV: Same as SD365-IV but with ULC listing SD365T: White, same as SD365 but includes a built-in 135°F (57°C) fixed-temperature thermal device, LiteSpeed only SD365TA: Same as SD365T but with ULC listing SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F (57°C) fixed-temperature thermal device SD365TA-IV: Same as SD365T-IV but with ULC listing SD365R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, LiteSpeed only SD365RA: Same as 5D365R but with ULC listing, for use with DNRA SD365R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW SD365RA-IV: Same as SD365R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B200SA-WH: Same as B200S-WH, ULC listing B200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base TR300-IV: Ivory, replacement flange for B21OLP(A) base RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00: Test magnet with telescoping handle base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing B224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound outpUt in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) Page 2 of 3— DF-61010:C • 5/28/2020 CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack SYSTEM SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0 (51 mm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g) Operating temperature range: SD365: 32°F to 122°F (0°C to 50°C) SD365T Series: 32°F to 100°F(0°C to 38°C) 5D365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (o ne communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ('ON") DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the SD365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listing: S1059 FM Approved CSFM: 7272-0075:0502 LiteSpeedTM is a trademark, and Fire-Lite® Alarms and System Sensor& are registered trademarks of Honeywell International Inc. ©2020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Ml All specifications are subject to change without notice. & MNflFTIR1N QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX:(877) 6994105. Country of Origin: Mexico www.firelite.com Page 3 of 3— DF-61010:C • 5/28/2020 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I . I OFFICE OF THE STATE FIRE MARSHAL I(_q@I FIRE ENGINEERING & INVESTIGATIONS DIVISION 1) BUILDING MATERIALS LISTING PROGRAM N~ LISTING SERVICE LISTING No.: 7272-0075:0502 PARENT LISTING No.: 7272-0028:0503 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALAR INC. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, L,ia 2034846105 Email: lisa.brap(@honeywell.com DESIGN: Models SD365, SD365R and SD3651 analog addressable, photoelectric smoke detectors for open area and duct installations. Model SD3651 has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *13501 *B2IOLP (CSFM Listing 7300-1653:0109), *B350LP (CSFM Listing 7300-0075:0192), B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. NOTES: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I' I OFFICE OF THE STATE FIRE MARSHAL II FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE *Revision 12-17- 19 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06130/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 4'1~ D365PL(A) and DNRW Intelligent Non-relay Photoelectric Duct Smoke Detectors DF-62033:B (a Fire ueearms by Honeywell AddressableDevices The Fire-Lite D365PL(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct - smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5 - 20.32 m/s), temperatures of -4°F - 158°F (-20°C - 70°C), and a humidity range of 0 - 93 percent (non-condensing). An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Fire•Lite D365PL(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accessories. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/mm —4,000 ft/mm (0.5 m/s —20.32 mIs) Versatile mounting options: square or rectangular configuration Broad ranges for operating temperature (-4°F - 158°F, -20°C - 70°C) and humidity (0% - 93% non-condensing) Sampling tube installs from front or back of the detector with no tools required Cover tamper signal Increased wiring space with a newly added 3/4" conduit knockout Easily accessible code wheels on sensor head (Included with D365PUD365PLA) Clear cover for convenient visual inspection (D365PL(A) only) Remote testing capability Requires com line power only Housing accommodates an addressable relay module, sold sepa- rately, (CRF-300) for applications requiring a Form-C relay Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F - 158°F (-20°C - 70°C) Storage Temperature Range: -22°F - 158°F (-30°C - 70°C) Operating Humidity Range: 0% - 93% relative humidity (non-con- densing) Air Duct Velocity: 100 —4,000 ft/mm (0.5 - 20.32 m/s) Accessories Fire•Lite provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. ACCESSORY CURRENT LOADS AT24 VDC Device Standby Alarm RA100Z OmA 12mAMax RTS151/RTS151KEY OmA 12mAMax Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. UL: S1059 ULC: S1059 CSFM: 3242-00 Z FM approved Product j,1nformation NOTE: indicates ULC listed model. D365PL(A): Intelligent non-relay photoelectric low flow smoke detector housing. Includes SD365R(A)-IV detector. DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated. SD365R(A)-IV: Remote test capable addressable low-profile photo- electric smoke detector; ivory; supports CLIP and LiteSpeed TM pro- tocols SD365R(A): Remote test capable addressable low-profile photo- electric smoke detector; white; supports LiteSpeed protocol only SD365(A)-IV: Addressable low-profile photoelectric smoke detector; ivory; supports CLIP and LiteSpeed protocols 5D365(A): Addressable low-profile photoelectric smoke detector; white; supports LiteSpeed protocol only 5D365T(A): Addressable low-profile photoelectric smoke detector with a built-in 135°F (57°C) fixed-temperature thermal device; white; supports LiteSpeed protocol only SD365T(A)-IV: Addressable low-profile photoelectric smoke detec- tor with a built-in 135°F (57°C) fixed-temperature thermal device; ivory; supports LiteSpeed protocol only DF-62033:B • 7/2/2021 - Page 1 of 2 DUCTCOV: Retrofit D355PL(A) cover for detectors manufactured prior to April 2014 DUCTCOVW: Retrofit DNRW cover for detectors manufactured prior to April 2014 DST1: Metal sampling tube duct width up to 1 ft (0.3 m) DST1.5: Metal sampling tube duct widths up to 1 ft - 2 ft (0.3 - 0.6 m) DST3: Metal sampling tube duct widths up to 2 ft —4 ft (0.6 - 1.2 m) DST5: Metal sampling tube duct widths up to 4 ft —8 ft (1.2 - 2.4 m) DST10: Metal sampling tube duct widths up to 8 ft - 12 ft (2.4 - 3.7 m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RAlOOZ(A): Remote annunciator alarm LED RT'Sl 51: Remote test station RTS1 51 KEY(-A): Remote test station with key lock LiteSpeedTM is a trademark; and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02021 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. g • All specifications are subject to change without notice. 19111111131111111 & FiWIIMtflRIN QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. Country of Origin: Mexicc www.firelite.com Page 2 of 2— DF-62033:B • 7/2/2021 ONE& CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 3242-0075:0508 CATEGORY: 3242 - DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: FIRE-LITE ALARC. One Fire-Lite Place, Nohford, CT, 06472 Contact: Brantjtsa (203) 484-6105 (203) 484-7309 Email: Iisa.ba1it©honeywell.com DESIGN: Model D365PL Photoelectric duct analog smoke detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric duct analog smoke detector for use with System Sensor Model B501 base (CSFM Listing 7300-1653:0109) and separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTES: 08-01-19 gt This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test f\ results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational i ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Listing Expires: 06/3012025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 SYSTEM $ SENSOR Duct Smoke Detector Accessories Expand the versatility of the Inn ovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn,White RA1 OOZ/RA 100ZA Remote Annunciator RTS151 ote Test Station RTS1S1KEY Remote Test Station with Key RTS2 Multi-Sianalina Accessory Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA1S1 plezo annunciator, which replaces the APA45 1 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. AOS RTS2-AOS Add-On Strobe The MHR and MHW SpectrAlerf Advance mini-horns feature Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired., The RA100Z and RA100ZA remote ayI 'ciators are designed for both conventional and intelligey'pplications.Their red LED provides visual indication of an rm condition. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS15 1 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. Agency Listings The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accassor Voltage Regulated 24 VDC OperalingVoltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49't (32°F to 120°9 Relative Humidity 10 to 93% non-condensing Wire Gauge 12 to 18AWG Dimensions 4.6H x 29-Wx .45D Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33VDC (9 to 33VDC with Sync-Circuit' Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max at8to 17.5 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3kHz Wire Gauge 12 to 18AWG Dimensions 4.6H x 2.9Wx 045D Voltage Range Conventional System: 3.1 to32VDC Intelligent System: 18 to32VDC Maximum Alarm Current 12 mA Dimensions 4.6 H x 2W x13"D RTS151 UL S4011 RTS1S1 KEY ULS2S22 ra Vow ro - RA100Z UL 52522 MI-lW UL S4011 les RTS151 Remote TestSta bon Power Requirements Alarm LED: 2.8to32VDC 12 mA max. Total Current: 105 mA max. Test Switch 10VA@32VDC Reset Switch 10 VA @ 32VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.8Hx 2.90Wx 1.4D Power Requirements Power LED (Green): 14 to 35VDC. 12 mA max. Alarm LED (Re: 2.8 to 32VDC. 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions RTS2 and RTS2-AOS Multi Voltage 4.6Hx2.75Wx 1.8D -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to22AWG Dimensions 4.8Wx5.3Hx 1.6D For the very latest product specifications and listing infcrmation, please visit the System Sensor Web site at vw.systemsensor.com. SMOKE - La ~A` APA151 UL S4011 RTS2-AOS UL S2522 MHRULS4O11 AOS S)'S7'EII,1 3825 Ohio Avenue. St. Charles IL 60174 P t tb "°° 5,IJsoRe Phone: 800-SENSOR2 Fax: 630-377-6495 the bbnafthdatasheet. AD5.0423.001 .2flO-23OO CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM Nzr LISTING SERVICE LISTING No.: 7300-1653:0212 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated D!y'f Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 / Contact: Brant, Lisa 20348461 9 Email: Iisa.brant©honeyw2Aom DESIGN: Models RTS1 51, RTSI 51 KEY and RAIOOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTES: 04-03-09 bh This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 DF-52013:1) • E-100 BG-1 2LX - FlreuTeALarms Addressable Manual Pull Station by Honeywell Addressable Devices The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-la or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, 0r4° (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-1 2LX will mount semi-flush into a single-gang, double- gang, or standard 4° (10.16 cm) square electrical outlet box, or will surface mount to the model SB-b 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-520130 • 4/13/2012 - Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0075:0184. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite® Alarms® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 1I We cannot cover all specific applications or anticipate all requirements. MCINEEIIIIIIII & MANIF*C11RIN QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.tirelite.com Page 2 of 2— DF-52013:D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I I OFFICE OF THE STATE FIRE MARSHAL , FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N LISTING SERVICE LISTING No.: 7150-0075:0184 PARENT LISTING No.: 7150-0028:0199 CATEGORY: 7150- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALMS INC. One Fire-Lite Place, Northford, CT, 06472 Contact: Brapl, Lisa 2034846105 Email: lisa)5rant@honeywell.com DESIGN: / ModeiBG-12, BG-125, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-12LWP, BG-12L BG-I2LX, BG-I2LA, BG-I2PS, BG-I2LSP, BG-I2SP, BG-I2LR, BG-I2LRA, BG- I2LAO, BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-12LPS, BG-I2LPSP, BG-I2SL, UT- PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12L0B are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTES: *Updated 08-17- 09 fm Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I I OFFICE OF THE STATE FIRE MARSHAL II FIRE ENGINEERING & INVESTIGATIONS DIVISION I"", BUILDING MATERIALS LISTING PROGRAM Nzr LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test resultsand/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/08/2024 Listing Expires: 06130/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 DF-52121:C • E-325 MMF-300(A) Series, MDF-300(A) (9F1M-L1TffALWMS Addressable Monitor Modules IJY I IJI Iy VVII Addressable General Four different monitor modules are available for FiresLite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standaj4zed module (typically mounts to a 4 [10.16 cm] squa'6ox) that supervises either a Style D (Class A) or S B (Class B) circuit of dry-contact input devices. MMF-301( is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75 (6.985 cm) W x 0.5 (1.270 cm) D used to super- vise a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301 (A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTm is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. designs. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit nsups(., 3LC(•)T2 MMF-300(A) (Type H) may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 450 (11.43 cm) high x 40 (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 40 (10.16 cm) square x 2.1250 (5.398 cm) deep box. DF-52121 :C • 10/06/2010 - Page 1 of 4 MMF-301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS 0 11 4 0.." 0'~. " L:: TENS ONES II III... II I oil 11w _jll IIi 1 ..jll IIQ II lI Ico The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 (A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF- 302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125 (5.398 cm) deep box. Page 2 of 4— DF-521 21:C • 10/06/2010 MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses 26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 40 (10.16 cm) square, 2.1250 (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM Approved CSFM: 7300-0075:0185 MEA:72-01-E Product Line Information NOTE: "A" suffix indicatej,JJ;sted model. MMF-300(A): Mpidinodule. MMF-301 (A)lIonitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-521 21 :C • 10/06/2010 - Page 3 of 4 Fire-Lite® and UteSpeed® are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. 01111191111111111 A MMIMCIIRIN8 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121 :C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N~r LISTING SERVICE LISTING No.: 7300-0075:0185 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC. One ite Place, Nohford, CT, 06472 Contact: Brant, Lisa 20348461,05 Email: lisa.brant@honeYwej,6om DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VOC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTES: *Rev. 05-06-05 Jw This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/01/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 CRF-300(A) Relay Module General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedm is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. df-60379:A1 • E-400 (a Flrelrre®ALarms by Honeywell LIMED na,..,n TIC stcl.Ir, TENt? TStT•flN?NT SLCL.Ifl CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LJR=5ms) Coded 30 VDC 0.5 A Inductive (LIR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LfteSpeedTM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. is0 00i We try to keep our product information up-to-date and accurate. - • 1=1 We cannot cover all specific applications or anticipate all requirements. ENCINEENIG & MMUM131111111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— dt-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-0075:0185 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE AJLRMS INC. One Fire-Lite Place, Northford, CT, 06472 Contact: B~rit, Lisa 2034846105 Email: lisbranthoneywell.com DESIGN: / Mod4f MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTES: *Rev. 05-06-05 Jw This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/01/2024 Listing Expires: 06/3012025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 1 of 1 Li L-Series and L-Series with SYSTEM SENSOR / LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper-resistant construction Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use Agency Listings SIAIG SIGNAUNO LOM (9 @ APPROVED C(DIIIS Horn Strobes Horns: Horns: 3057072 7300-1653:0525 and Strobes: S4011 S4011 FM23FPtJS0195 1135-1553:0503 S5512, S4011 7135-1653:0526 The System Sensor L.Series and L.Series with LED platform otters the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology otters significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification appliances otter a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. AVDS916-01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Current Draw Data, Horn Tones, and Sound Output Data Candela Rating 1633 Volts Wall Ceiling Candela 15 18 18 Range 30 22 22 75 70 70 95 75 75 110 85 - 115 - 90 135 105 - 150 - 110 177 - 115 185 120 - Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hicih 42 43 54 IJ Will -pDraw (mA) and Sound Output (dBA) Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 Cd) Sound Output (dBA) Switch Pos. Sound Pattern Volume Setting 15cd 30cd 75cd 95cd 16-33 Volts llOcd 115cd WALL CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd WALL 16-33V DC 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916.01 • 10)03/2023 • Page 2 (64mm) II 6.83" diam. (173.5 mm) 6.92" 4ia,m (175. L-Series with LED Dimensions: Wall-Mounted Equipment 297 1.55" m 3.46 53mm) 3.46" Be mm (3.9-)) - 1.25" 3.57" (31.8 m) iii LIP 10 I: r 88 MM 32mm (9.1 cm) 1m (1&7 cm) 3.27" 133.9 mm , A0617.00 A0547-00 A0557.00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) A0613.00 nI t85. (4.69 cm) 0 A0554-01 Strobes, Horn Strobes Horn Surface Mount Back Box for Walls for Walls ( SBBRLJSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment A0608-OO A0546.00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDSS 15.01 • 10)03/2023 • Page 3 L-Series with LED: Ordering Information L-Series with LED Horn Strobes P2RLED 2-Wire, Horn Strobe, Wall, Red P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual P2GWLED 2-Wire, Compact Horn Strobe, Wall, White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, Bilingual P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO PC2RLED 2-Wire, Horn Strobe, Ceiling, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual PC2WLED 2-Wire, Horn Strobe, Ceiling, White PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual L-Series with LED Strobes SRLED Strobe, Wall, Red SRLED-B Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, WjfrRed, FUEGO SWLED-CLR- ALERT Strobp'all, White, ALERT 7' SWLED-ALER.,'Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red SCRLED-B Strobe, Ceiling, Red, Bilingual SCRLED-P Strobe, Ceiling, White, Plain SCWLED Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- ALERT Strobe, Ceiling, White, ALERT L-Series Horns HRL* Horn, Red HRLA* Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC Model Description LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-B3 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White TRC-2 Universal Ceiling Trim Ring, Red TRC-2W Universal Ceiling Trim Ring, White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Bezelst BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. All -B models have "FIRE/FEU" marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: Horn-only models are listed for wall or ceiling use. Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). f SYSTEM $ SENSOR 3825 Ohio Avenue • St. Charles, IL 60174 USA Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada Phone: 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca System Sensor is a registered trademark of Honeywell International, Inc. 102023 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data street. AVDS916.01 • 10103/2023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N:;r LISTING SERVICE LISTING No.: 7300-1653:0525 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant, Lisa 2034846105 Email: Iisa.brant©honeywell.com DESIGN: Models SRLED, SWLED, SRLED-B, SW D-B, SRLED-P, SWLED-P, SRLED-SP, SWLED-SP, SWLED-CLR-ALERT, SCRLED, SCWLED, SCRLED-B, SCWLED-B, SCRLED-P, SCWLED-P, SCWLED-CLR-ALERT, SGRLED, SGWLED, SGRLED-B, SGWLED-B Ceiling or Wall Strobes. The 2-wire strobes come with 8 field selectable tone combinations and 7 field selectable candela settings. Models maybe mounted on the wall or ceiling as indicated and are intended for indoor dry/damp use only. Language designators: "-B" are bilingual (English/French). "-P" are plain versions (no wording). "-SP" are marked "FUEGO". Refer to listee's data sheet for additional detailed products description and operational considerations. RATING: 16-33 VDC Candela Ratings (cd): Wall Strobes: 15, 30, 75, 95, 110, 135, 185 Ceiling Strobes: 15, 30, 75, 95, 115, 150, 177 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's Name, Model Number, Rating, and UL Label. APPROVAL: Listed as strobes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Model complies with the applicable requirements in UL 1638, 6th Edition and UL 1971, 3rd Edition. NOTES: 9-18-23 DAL Page 1 of 2 00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/29/2024 Listing Expires: 06130/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 SYSTEM ~~~ SENSOR® L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper-resistant construction Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115,150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use The System Sensor L.Series and L.Series with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without C©US USTED Horn Strobes and Strobes: 55512, $4011 SIGNALING LISTED Horns: 54011 LISTED Horns- 54011 APPROVED 3057072 FM23FPUS0195 7000-1653:0525 7135-1653:0603 7135-1653:0526 removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting. AVDS91E-01 • 10/0312023 • Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG ULIULC Current Draw Data, Horn Tones, and Sound Output Data Candela Rating 16-33 Volts Wall Ceiling Candela 15 18 18 Range 30 22 22 75 70 70 95 75 75 110 85 - 115 - 90 135 105 - 150 - 110 177 - 115 185 120 - 8-17.5Volts 16-33Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UIJULC MaximumiHorn iiCurrentiDrawI ISound Ou Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 Cd) Sound Output (dBA) Switch Pos. Sound Pattern Volume Setting 15cd 30cd 75cd 95cd 16-33 Volts llOcd 115cd WALL CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd 16-33V WALL DC 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916.01 • 10/03/2023 • Page 2 A0613-OO Horn Strobes, Horn Strobes for Walls 32 non ( 442 '1224cm) (4.69 am) t55 LIP Y OP 0 Ij L-n 125 - 5.78' (14.65cm) — 0 "M Lo~~ A0549-00 A0554-01 Surface Mount Back Box for Walls ( SBBRLISBBWL) 6.63 am. (173.5 mm) 6.92 141m (175; L-Series with LED Dimensions: Wall-Mounted Equipment 2.Or OM M) SImm t25 3$7• t55 88 MM (31.1) 32 MM (9.1 cm) (3.9cm) 0, a 334 MM OCE- A0617-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls (SBBGRL, SBBGWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment A0608-OO A0546-OO Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDSI1601 • 10/0312023 • Page 3 L-Series with LED: Ordering Information L-Series with LED Horn Strobes P2RLED 2-Wire, Horn Strobe, Wall, Red P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual P2GWLED 2-Wire, Compact Horn Strobe, Wall, White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, Bilingual P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain P2WLED-P 2-Wire, Horn Strobe, Wall, White, Plain P2RLED-SP 2-Wire, Horn Strobe, Wall, Red, FUEGO P2WLED-SP 2-Wire, Horn Strobe, Wall, White, FUEGO PC2RLED 2-Wire, Horn Strobe, Ceiling, Red PC2RLED-B 2-Wire,Jn Strobe, Ceiling, Red, Bilingual PC2WLED 2-üc Horn Strobe, Ceiling, White PC2WLED-B ,'I -Wire, Horn Strobe, Ceiling, White, Bilingual L-Series )vjWCED Strobes SRLED Strobe, Wall, Red SRLED-B Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- ALERT Strobe, Wall, White, ALERT SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red SCRLED-B Strobe, Ceiling, Red, Bilingual SCRLED-P Strobe, Ceiling, White, Plain SCWLED Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- ALERT Strobe, Ceiling, White, ALERT L-Serles Horns HRL* Horn, Red HRLA° Horn, Red, Plain, ULC HWL° Horn, White HWL.A* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-B3 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White TRC-2 Universal Ceiling Trim Ring, Red TRC-2W Universal Ceiling Trim Ring, White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Bezeist BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceilina White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no 'FIRE' marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. All -B models have "FIRE/FEU" marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: 'Horn-only models are listed for wall or ceiling use. Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). 3825 Ohio Avenue • St. Charles, IL 60174 USA Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com F' 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada 5EAISOR Phone. 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca System Sensor* is a registered trademark of Honeywell International. Inc. /02023 system sensor. Product specifications subjectto strange wittmut noOce. Visit systemsenscr.can for curent product nformahori, fostud,g the latest yeoman of this data sheet AV05916-01 • 10/03/2023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N;r LISTINGS RVIC LISTING No.: 7300-1653:0525 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, L41 'incorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 / Contact: Brant /Lisa 2034846105 Email: jisa. _nt@honeywell.com DESIGN: Models SRLED, SWLED, SRLED-B, SWLED-B, SRLED-P, SWLED-P, SRLED-SP, SWLED-SP, SWLED-CLR-ALERT, SCRLED, SCWLED, SCRLED-B, SCWLED-B, SCRLED-P, SCWLED-P, SCWLED-CLR-ALERT, SGRLED, SGWLED, SGRLED-B, SGWLED-B Ceiling or Wall Strobes. The 2-wire strobes come with 8 field selectable tone combinations and 7 field selectable candela settings. Models maybe mounted on the wall or ceiling as indicated and are intended for indoor dry/damp use only. Language designators: "-B" are bilingual (English/French). "-P" are plain versions (no wording). "-SP" are marked "FUEGO". Refer to listee's data sheet for additional detailed products description and operational considerations. RATING: 16-33 VDC Candela Ratings (Cd): Wall Strobes: 15, 30, 75, 95, 110, 135, 185 Ceiling Strobes: 15, 30, 75, 95, 115, 150, 177 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's Name, Model Number, Rating, and UL Label. APPROVAL: Listed as strobes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Model complies with the applicable requirements in UL 1638, 6th Edition and UL 1971, 3rd Edition. NOTES: 9-18-23 DAL Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM N;r LISTINGS RVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/29/2024 Listing Expires: 06130/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 SYSTEM $ SENSOR® L.Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features LED technology provides lower current draw Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes Common aesthetics across the L-Series platform Standard and compact sizes Tamper-resistant construction Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switches for candela, tone and volume selections Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module Horns, Strobes and Horn Strobes listed for wall or ceiling use The System Sensor L-Serlos and L.Series with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations. Flexible design options meet virtually any application requirement: wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches. The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed. In addition, the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without SIALG c®us SIGNAliNG removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which USTED APPROVED enable faster troubleshooting and end of line (EOL) voltage checks USTED USTED Horn Strobes Horns: HOrnS. 3057072 7300.1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: S5512,S4011 S4011 S4011 FM23FPUS0I95 7130.1653:0003 7135-1653:0526 during troubleshooting. AVDS916.01 • 10/03/2023 • Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Current Draw Data, Horn Tones, and Sound Output Data Candela 16-33 Volts Rating Wall Ceiling Candela 15 18 18 Range 30 22 22 75 70 70 95 75 75 110 85 - 115 - 90 135 105 - 150 - 110 177 - 115 185 120 - 8-175 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 - 29 54 Coded High 43 47 54 3.1 KHz Coded Hiqh 42 43 54 UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA) Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 Cd) Sound Output (dBA) Switch Pos. Sound Pattern Volume Setting 15cd 30cd 75cd 95cd 16-33 Volts llOcd 115cd WALL CEILING 135cd WALL 150cd CEILING 177cd CEILING 185cd 16-33V WALL DC 1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-0 • 10/03/2023 • Page 2 6.83 diam. (173.5 mm) 6.92 fmm. (175, L-Series with LED Dimensions: Wall-Mounted Equipment as MM h? A0617-OO Compact Strobe, Horn Strobe for Wall k— 348 a mm 32 mm -347'- 1 t55. (3.1cm) (3.9cm) t I uP= 5.38• I33 mm F?gf (13.7cm) A0547.00 A0557.00 Compact Horn Compact Surface Mount Back Box for Walls (SBBGRL, SBBGWL) 1.25 4.92 - 32 mm (1224 cm) I I k-4-- ts• - 3.78• (1&cm) A0549-00 A0554-01 Surface Mount Back Box for Walls ( SBBRL/SBBWL) Strobes, Horn Strobes for Walls A0613.00 Horn L-Series with LED Dimensions: Ceiling-Mounted Equipment A0608-OO A0546-OO Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings (SBBCRL, SBCWL) AVDS916.01 • 10103/2023 • Page 3 L-Series with LED: Ordering Information L-Series wltkED Horn Strobes P2RLED 2-Wire, Horn Strobe, Wall, Red P2RLED-B 2-Wire, Horn Strobe, Wall, Red, Bilingual P2WLED 2-Wire, Horn Strobe, Wall, White P2WLED-B 2-Wire, Horn Strobe, Wall, White, Bilingual P2GRLED 2-Wire, Compact Horn Strobe, Wall, Red LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-B3 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-133 Lens LED Red Wall/Ceiling Accessories P2GRLED-B 2-Wire, Compact Horn Strobe, Wall, Red, Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire, Compact Horn Strobe, Wall, White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire, Compact Horn Strobe, Wall, White, SBBRL Wall Surface Mount Back Box, Red Bilingual SBBWL Wall Surface Mount Back Box, White P2RLED-P 2-Wire, Horn Strobe, Wall, Red, Plain SBBGRL Compact Wall Surface Mount Back Box, Red P2WLED-P 2-Wire,J10rn Strobe, Wall, White, Plain SBBGWL Compact Wall Surface Mount Back Box, White P2RLED-SP 2Ke, Horn Strobe, Wall, Red, FUEGO TRC-2 Universal Ceiling Trim Ring, Red P2WLED-SP -12-Wire, Horn Strobe, Wall, White, FUEGO TRC-2W Universal Ceiling Trim Ring, White PC2RLED 2-Wire, Horn Strobe, Ceiling, Red SBBCRL Ceiling Surface Mount Back Box, Red PC2RLED-B 2-Wire, Horn Strobe, Ceiling, Red, Bilingual SBBCWL Ceiling Surface Mount Back Box, White PC2WLED 2-Wire, Horn Strobe, Ceiling, White Bezeist PC2WLED-B 2-Wire, Horn Strobe, Ceiling, White, Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe, Wall, Red SRLED-B Strobe, Wall, Red, Bilingual SWLED Strobe, Wall, White SWLED-B Strobe, Wall, White, Bilingual SGRLED Strobe, Compact, Wall, Red SGRLED-B Strobe, Compact, Wall, Red, Bilingual SGWLED Strobe, Compact, Wall, White SGWLED-B Strobe, Compact, Wall, White, Bilingual SRLED-P Strobe, Wall, Red, Plain SWLED-P Strobe, Wall, White, Plain SRLED-SP Strobe, Wall, Red, FUEGO SWLED-CLR- ALERT Strobe, Wall, White, ALERT SWLED-ALERT Strobe, Wall, White, ALERT, Amber Lens SCRLED Strobe, Ceiling, Red SCRLED-B Strobe, Ceiling, Red, Bilingual SCRLED-P Strobe, Ceiling, White, Plain SCWLED Strobe, Ceiling, White SCWLED-B Strobe, Ceiling, White, Bilingual SCWLED-P Strobe, Ceiling, White, Plain SCWLED-CLR- ALERT Strobe, Ceiling, White, ALERT L-Series Horns HRL* Horn, Red HRLA* Horn, Red, Plain, ULC HWL* Horn, White HWLA* Horn, White, Plain, ULC HGRL* Compact Horn, Red HGRLA* Compact Horn, Red, Plain, ULC HGWL* Compact Horn, White HGWLA* Compact Horn, White, Plain, ULC BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit Notes for L-Series With LED Horn Strobes and Strobes: All -P models have a plain housing (no 'FIRE marking on cover). All -SP models have "FUEGO marking on cover. All -ALERT models have 'ALERT marking on cover. All -B models have "FIRE/FEU" marking on cover for use in Canadian applications. Amber lenses are not for use in Canadian applications Notes for L-Series Horns: 1-forn-only models are listed for wall or Ceiling use. Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options: -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -FR (FEU), -PG (FOGO), -SP (FUEGO), -SPE (FUEGO/FIRE). 3625 Ohio Avenue • St. Charles, IL 60174 USA System Sensor Is a registered trademark Phone: 800-SENSOR2 • Fax: 630-377-6495 of Honeywell International, Inc. www.systemsensor.com "STEM 3333 Unity Drive, Mississauga, ON L5L 3S6 Canada 02023 System Sensor. ELSOR Phone: 800-SENSOR2 • Fax: 905-812-0771 Prodactspeca0ons subject to change dce.stsystenoensor.can 1st crerent product sforma0st including the latest version of this data street www.systemsensor.ca AvDs916-01 • 10103/2023 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC LISTING No.: 7135-1653:0526 CATEGORY: 7135-AUDIBLE DEVICES LISTEE: System Sensor, incorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL, 60174 CntactBran2 203484 DESIGN: Email: lisa.@1o29ffcom Models P2RLED, P2 D, P2RLED-B, P2WLED-B, P2RLED-P, P2WLED-P, P2RLED- SP, P2WLED-SP, PC2RLED, PC2WLED, PC2RLED-B, PC2WLED-B, P2GRLED, P2GWLED, P2GRLED-B, P2GWLED-B Ceiling or Wall Horn Strobes. The horn strobes come with 8 field selectable tone combinations and 7 field selectable candela settings. Models maybe mounted on the wall or ceiling as indicated and are intended for indoor dry/damp use only. Language designators: "-B" are bilingual (English/French). "-P" are plain versions (no wording). "-SP" are marked 'FUEGO". Refer to listee's data sheet for additional detailed products description and operational considerations. RATING: 16-33 VDC Candela Ratings (cd): Wall Horn Strobes: 15, 30, 75, 95, 110, 135, 185 Ceiling Horn Strobes: 15, 30, 75, 95, 115, 150, 177 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's Name, Model Number, Rating, and UL Label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Model complies with the applicable requirements in UL 464, 11th Edition, UL 1638, 6th Edition, and UL 1971, 3rd Edition. NOTES: 9-18-23 DAL This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Listing Expires: 06/30/2025 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 4 ~ SYSTEM ~4, SENSOR®VV Outdoor Selectable= Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert Advance outdoor audible visible products are rich with features that cut installation times and Ir!,sy sor maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15,15/75,30,75,95,110,115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNAUNG corrosion. Knock-outs located on the back eliminate the need to drill 01 holes for screw-in mounting. Plastic and metal weatherproof back IE1A 7300.1653187 (Outdoor strobes) boxes come with 34-inch top and bottom conduit entries and 34-inch USTED approved 7125-1653:188 (horn strobes, knock-outs at the back. A screw-in NPT plug with an 0-ring gasket S4011 (chimes, horn strobes, horns) ov S3593 (outdoor and alert strobes) 3023572 chime strobes) M6A452-05-E 7135-1653:189 (horns, chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit ° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder, The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6'L x 4.7"W x 1.3"D (142 mm Lx 119 mm x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1"W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSO12O1 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal - High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output (dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 83 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS0201 Strobe sITf I J Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 1 177 185 1185 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams -w Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t _ Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. I-Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM Ohio Avenue • St. Charles, IL 60174 @2012 System Sensor. $YSTE Product specifications subject to change without notate. Visit Systemsensor.corn SENSOR Phone: 800-SENSOR2 • Fax- 630-377-6495 05 current product information, including the latest version of this data sheet. AVD501201 .3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1653:0187 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant, Lisa 2034846105 Email: lisa.brant©honeywell.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 660C)* rating and are NEMA4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTES: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22- 10 fm This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational 7 requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Listing Expires: 06/30/2025 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 Fire/Life Safety SmartWireTM UL Listed and Rated Type CMP or FPLP Multi-Conductor Non-Shielded Plenum Fire Alarm 162FP - 16 AWG 2 Conductor Non-Shielded Plenum Fire Alarm Description [16 AWG 2 conductor Bare copper, Non- Shielded Plenum Fire 1Alarm, UL C(UL) CMP or FPLP UL Conductor Description 1r16 (Solid Bare - _______ jcopper) Insulation Low-Smoke PVC L .o1 o" color Code acWRed backet Low-Smoke PVc Marking FIRE/LIFESAFEIY' CABLE IcONTROL INIT. / IND. DEVICE / ZONE A B c ID E 0 1 23456789 16 AWG UL C(UL) CMP OR FPLP UL ROHS MADE IN THE USA r Overall Diameter .178 Nom ,Capacitance Temperature and iO Cto oitage Rathig - jOO Volt Cable Weight 26 Lbs/Mft. Flame Rating: Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test Agencies Approvals: NEC Article 800, 760; UL C(UL) CMP or FPLP UL, RoHS Compliant, Made in the USA C® Fire/Life Safety SmartWireTm UL Listed and Rated Type COP or FPLP Multi-Conductor Non-Shielded Plenum Fire Alarm 122FP - 12 AWG 2 Conductor Non-Shielded Plenum Fire Alarm : Fire Alarm, UL inductor Description Color Code Jacket CL3P or FPLP UL JTS~o ic Bare Copper) Low-Smoke PVC .010 018' Marking FIRE/LIFE SAFETY CONTROL CABLE INIT. I IND. DEVICE I ZONE A B C D E 0 2 3 4 5 6 7 8 9 12 AWG UL C(UL) CUP OR FPLP UL ROHS MADE IN THE rall Diameter 1[238 Nom. ICapacitance 1[34PF/FLNom. - I emperature and Voltage Rating 0 Cto 75C/300 Volt - Cable Weight f3 Lbs/Mft. Flame Rating: Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test Agencies Approvals: NEC Article 800, 760; UL C(UL) COP or FPLP UL, RoHS Compliant, Made in the USA UL Listed and Rated Type TC, PLTC, FPL OR NPLF Multi-Conductor Non-Shielded Non-Plenum Cable CSFM# 7161-1727:0100 H2+162 Ccr Non-Shielded Non-Plenum Quad Rated Fire Alarm Description 1 16 AWG 2 Conductor Bare Copper, Non-Shielded Non- Plenum Quad Rated Fire lAlarm UL Type TC, PLTC, LorNPLF i(19 Strand Bare Copper) with Nylon 1'Cond- uctor Insulation 7PVC olor Code Black/Red [Jacket rC040Norn ] Marking WINDY CITY WIRE A B C D 0 1 2 3 45 6 789 16AWG (UL) TYPE TC 600V 90C DRY 75C WET 'DIR BUR' 'SUN RES PLTC, FPL OR NPLF MADE IN THE USA SMART WIRE jNTERWARRIOR®' Diameter 1 34 Nom. Impedance 7, Ohms/Mft. iYS fternperature and i!OCtoio5c/600 jVoltage Rating CableW&ght 1,42 Lbs/Mft. 1 Agencies Approvals: UL Standard 1277, UL 1424 Power limited fire alarm cables, UL 1425 Non-power limited fire alarm cables, UL 13 power limited circuit cables, NEC Articles 340, 725, 760, Made in the USA