Loading...
HomeMy WebLinkAbout2544 CAMPBELL PL; B; FPC2020-0003; Permit(City of PERMIT REPORT Carlsbad Print Date: 02/12/2025 Permit No: FPC2020-0003 Job Address: 2544 CAMPBELL P1, # BLDG B, CARLSBAD, CA 92009-1768 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132611800 Track #: Applied: 01/09/2020 Valuation: $0.00 Lot #: Issued: 01/24/2020 Occupancy Group: Project #: Finaled Close Out: 02/12/2025 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Salcedo, Felix Project Title: Description: CAMPBELL PLACE - 2ND SET OF REVISED PLANS FOR SPRINKLER TI (45 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System 7- 100 heads $553.00 FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Plan Review Per Hour - Office Hours $204.00 Total Fees: $1,211.00 Total Payments To Date: $1,211.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Opine PROTECTOH Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 19123 CAMPBELL PLACE 2544 CAMPBELL PLACE, BLDG. B Carlsbad, CA 92009 For Light Hazard Occupancies Only NOTE: As of May 2018 all logos have been removed from the wrench boss. WARNING: Cancer and Reproductive Harm- Specifications: www.P65Warnings.ca.gov Available since 2013. Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread sizes: 3/4" (20 mm) NPT Nominal K-Factors: 8.0 U.S. (115.2 metrict) t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) Refer to Approval Chart I and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESCRIPTION Viking EC/QREC Pendent Sprinkler VK602 is a small thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. This sprinkler has both standard response and quick response listings. The glass bulb operating element and special deflector char- acteristics meet the challenges of quick response extended coverage standards. The special Polyester coating can be used in decorative applications where colors are desired. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2020 Material Standards: Sprinkler Frame: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order EC/QREC Pendent Sprinkler VK602 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester M-/W, and Black Polyester M-/B Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) B, 175°F (79 °C) = D For example, sprinkler VK602 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18262BAB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017) Wrench for recessed pendent sprinklers: Part No. 13577W/B** (available since 2006) **A /2" ratchet is required (not available from Viking). Form No. F_102412 19.02.21 Rev 19.1 Replaces Form No. F_102412 Rev 18.2.P65 (Removed F-I Escutcheon.) Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5 OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands,causing the glass to shatter, releasing the pip cap and sealing springassembly. Water flowing through the sprinkler orifice strikes the sprinklerdeflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking ECIQREC Pendent Sprinkler VK602 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nonnal Maxinum Ambient - Classification Temperature 'Rating' CeIin TempeFature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester', and Black Polyester3 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. ..........—Wrench Flat Protective Sprinkler z Clip Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_102412 19.02.21 Rev 19.1 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Approval Chart I (UL) Temperature KEY Standard/Quick Response Extended Coverage Pendent Sprinkler FS For Light Hazard Occupancies Only. AIX + Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Areas of Coverage 4 Minimum Water Supply Requirements Listings and Approvals' Part No.' (Refer also to Design Criteria.) Inches mm U.S. metric' (Length x Width) Standard Response Applications' cULus5 18262 VK602 3/4 20 [8.0 115.2 20' x 20' (6.1 m x 6.1 m) 40 gpm @ 25.0 psi (151.4 L/min @ 1.72 Bar) A1Z Quick Response Applications 18262 VK602 3/4 20 8.0 115.2 16' x 16' (4.9 m x 4.9 m) 26 gpm @ 10.6 psi (98.4 11mm @0.73 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m x 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min © 1.17 Bar) C1Z 18262 VK602 3/4 20 8.0 115.2 20'x 20'(6.1 m x 6.1 m) 40 gpm @25.0 psi (151.4 L/min @ 1.72 Bar) I I j B1Y t.)ICE - Product i:ft Limited Availability Standard Response Applications6 cULus5 07077 1 VK602 3/4 20 8.0 115.2 20'x 20'(6.1 m x 6.1 m) 40 gpm @25.0 psi (151.4 LJmin @ 1.72 Bar) A1Z Quick Response Applications 07077 VK602 3/4 20 8.0 115.2 16' x 16' (4.9 m x 4.9 m) 26 gpm @ 10.6 psi (98.4 L/min @0.73 Bar) ' C1Z 07077 VK602 3/4 20 8.0 115.2 18' x 18' (5.5 m x 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) C1Z 07077 VK602 3/4 20 8.0 115.2 20' x 20' (6.1 mx 6.1 m) 40 gpm @25.0 psi (151.4 Llmin @ 1.72 Bar) B1Y Sprinkler Temperature Ratings Approved Finishes Approved Escutcheons A- 155°F (68 *C) and 175°F (79 °C) 1 - Brass, Chrome, White Y- Standard surface-mounted escutcheons B - 135 °F (57 °C) Polyester, and Black Z - Standard surface-mounted escutcheons or recessed with the C - 135°F (57 °C), 155°F (68 °C), and 175 °F (79 °C) Polyester Micromatic8 Model E-1 or E-2 Recessed Escutcheon Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per sprinkler. Listed by Underwriter's Laboratories, Inc. for use in the U.S. and Canada for Light Hazard occupancies with smooth, flat, horizontal ceilings only. 6 cULus Listings are limited to Light Hazard occupancies, where allowed by the installation standards being applied. Form No. F102412 19.02.21 Rev 19.1 Sprinkler Wrench 3577W/Bww must be used for installing recessed sprinkler VK600 and VK602 *A 1/2k ratchet is quireci (not available from Viking). Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. DESlGNCRITERlA.-,UL cULus Listing Requirements: Standard/Quick Response Extended Coverage Pendent Sprinkler SIN VK602 is cULus Listed as indicated in the Approval Chart for installation in ac- cordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers: Limited to Light Hazard occupancies, where allowed by the installation standards being applied, with smooth, flat, horizontal ceilings only. Minimum spacing allowed is 8 ft. (2.4 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured per- pendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Step 1 Carefi wrench sicle the sprinkle and protec (Note the orienuiion Di- the shield in the wrench.) ...p 2 Carefully press the wrench upward and ensure engagement with The sprinkler wrench flats Figure 2: Wrench 13577W/B for Recessed Pendent Sprinkler VK602 Form No. F_102412 19.02.21 Rev 19.1 Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Approval Chart 2 (FM) Temperature KEY I Quick Response Extended Coverage Pendent Sprinkler Firssh (if AIX 4- Escutcheon applicabre)I Maximum 175 PSI (12 Bar) WWP Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Areas of Coverage Minimum Water Supply Requirements4 FM Approvals' (Refer also to Design Part Number' Flow/Pressure Inches mm U.S. metric2 (Length x Width) Criteria below.) 18262 VK602 3/4 20 8.0 115.2 16'x 16'(4.9 m x 4.9 m) 26 gpm @ 10.6 psi (98.4 LJmin @0.73 Bar) A1Z 18262 VK602 3/4 20 8.0 115.2 18'x 18'(5.5 m 5.5 m) 33 gpm @ 17.0 psi (124.9 L/min @ 1.17 Bar) A1Z 18262 VK602 3/4 20 8,0T11 5.2 20'x 20'(6.1 m x 6.1 m) 40 gpm @25.0 psi (151.4 Limin @ 1.72 Bar) A1Z Sprinkler Temperature Ratings Approved Finishes Approved Escutcheons A - 135 'F (57 'C), 155 'F (68 'C), and 1 - Brass, Chrome, White Poly-ester, Z - Standard surface-mounted escutcheons or the Viking Microfast® Model 175 'F (79 'C) and Black Polyester F-i Adjustable Escutcheon, or recessed with the Micro- matic® Model E-1 or E-2 Recessed Escutcheon Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger area listed with sprinklers of similar K- factor. Flows and pressures listed are per sprinkler. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM ADnroval Requirements: Quick Response Extended Coverage Pendent Sprinkler VK602 is FM Approved as quick response Non-Storage extended coverage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F102412 19.02.21 Rev 19.1 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com. Ceiling Opening Size: 2-5/16" (58,7 rim) minimum 2-1/2" (63,5 mm) maximum 3; (60 ) it 35 mm) Standard 1/8" (3,1 mm) Pendent Sprinkler surface-mounted escutcheon 18262 (VK602) Figure 3: Sprinkler VK602 Dimensions with a Standard Escutcheon Ceiling Opening Size: 2-5/16" (58,7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" 2-1/8" (54 mm) (54 mm) _______ 1 1-1/8" 2" (28.6 mm) (51 mm) Minimum "- Maximum -U--". H 1-3/4" 1-1/8" (28,6 mm) (45 mm) Minimum Maximum Installed with a Micromatic Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Sprinkler VK602 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_102412 19.02.21 Rev 19.1 Replaces Form No. F_i 02412 Rev 18.2.P65 (Removed F-i Escutcheon.) FireLock® V27, K5.6 Models V270311 V27071 V27041 V2708 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 Aac_t a ~ul i d 40.10 I V2703/V2704 V2 /07/V2708 V2707/V2 708 Upright Pendent Rçessed Pendent Approvals/Listings: See Victaulic Publication 10.01 for more details, Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /41719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 Si.' Nominal Thread Size: ½' NPT/15 mm Max. Working Pressure: 175 psil1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Job/Owner Engineer Exaggerated for clarity System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 ictaukc victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: fl Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: Open End: V27 Recessed: V27-2 Sprinkler Finishes: El Plain Brass Chrome plated White painted3 LII Black painted3 Custom painted3 LII Proprietary Nickel Teflon2 coating3 VC-250 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 \04t3uIic victaulic.com I Sprinklers I FireLockw I K5.6, V27 I Publication 40.10 Approvals/Listings: APPROVALS/LISTINGS Model ____________ V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" i/f i/f 1/7" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor SI.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/790C 155°F/68°C 155°F/68°C 155°F/680C 135°F/57°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 175°F/79'C 1750F/79°C 175°F/79°C 175°F/79°C 286°F/1410C 286°F/141°C 200° F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/1820C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/570C 1350F/570C 135°F/57°C 135°F/57°C FM 175°F/79°C 1750F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C200°F/93°C 360°F/1 82°C 360°F/182°C 2°F/141°C 86 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C NYC/MEA 62-99-E 175°F/79°C 175°F/790C 155°F/68°C 175°F/790C 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/930C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 1350F/57°C 135°F/57°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 1550F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 2860F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 1550F/68°C 135°F/570C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 1750F/79°C 286°F/1410C 200°F/930C 360'F/182°C 1350F/57°C 135°F/570C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/570C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/790C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141 °C 286 °F/141°C 200°F/93°C 200°F/93°C 200'F/93°C 200°F/93°C 360°F/182°C 360°F/1820C 286°F/141°C ° 286F/141°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 155°F/68°C 1750F/79°C VdS 200°F/93°C None None 175°F/79°C None None 286°F/1410C 360°F/182°C 135°F/57°C 155°F/68°C 175°F/79°C CE 200°F/93°C None None 175°F/79°C None None 286°F/1410C 200°F/930C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victauliccom 3 \JtauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: PA6I 37 mm _______ 1W! 2/e 'Tff 60 mm / 41 mm 60 mm I 41mm Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max Hole 2/51 mm Mm. Hole - mom ~YW/ -TTTIE~, I I Typical Ceiling Tile 30 Surface MAXIMUM RECESS 25117 - 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) -- 24 mm 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 4 jltaukc victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V270 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory ••• N t '%4 4 L4 I -----1— -1-- —1— -1-- ,.: L.. —4 -- \— -I - 7p*i 48 kPa 15 psi 103 kPa 30p11 a...... 207 kPa Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 1 % •_._ - I $1 24n,6_t_'_ 6 I iBm I I_I _'•--- I_t_4_-4 ----- _ •••t•_•4_* I _10, 12' i( 16' O.6mm1 1.21n 1.8rn 24n1 3.Om 33nm 43rn 49m 7ps1 48 kPa 15 psi 103 kPa 30p21: a. 207 kPa NOTES Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as Information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 \JtuIIc victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 Ff57 C 100 Ff38 C Orange Ordinary C 155 Ff68 C 100 Ff38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F193 C 150 Ff65 C Green High J 286 F/1 41 C 225 F 8f107 C Blue Extra High 7 K 360 F/1 82 C 300 Ff149 C Purple - M Open - No Bulb Standard resonse only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707,V2708Pendent V2707, V2708 Recessed Pendent ,( - V2703, V2704 Upright A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. O The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: ME AN 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in POP format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 6 \j6taulic SCHEDULE 10 PIPE sPEciPicArloNs NOMINAL PIPE 0,0, WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR" WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1,41 lbft 1.820 91 1.660 1,442 9.91 1.31 IbA 2.518 61 11/2 1.900 1.682 7.76 2.09 (bsItt 3.053 61 2 2.375 2.157 627 2.64tbft 4.223 37 2'112 2.875 2.635 4.92 3.53 1 be/ft 5.893 30 3 3.500 3.260 3.54 4.341bs/ft 7.957 19 4 4.500 4.260 2.90 5.62 IbsIft 11.196 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAtPIPE OD I.D 'fl WATERFILLED BUNDLE SIZE(IN) (IN) (IN) WEIGHT!FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 IbIft 2.055 70 11/4 1.660 1360 1.00 21nIbøt 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2,067 1.00 3.631b0t , 5.114 30 2-12" 2.375 2.468 1.00 5.80 lbs/It 7375 30 3 3500 3.068 1O0 7.58lbslft 10.783 19 4' 4.500 4.026 1.00 10.30 lbs/ft 16.316 19 Bull Moose Tube's' Schedule 10 and Schedule 40 are FM Approved and lit Listed (for U.S. and Canada), even thoh these products do not require separate approvals and listings. 8uIIF Moose Tube' made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been througb the same rigorous testing as our other one pipe products. Schedule 10 can be supplied roll grooved or plain end. 8u11 Moo eTube's'Scheduii 10 and Schedule 40 pipes are hot dipped galvanized to meet ASIM A123 standards; All products are stencilled to meet FM & UL specifications. Ris pdUt41 Dftwey ftmo c€us LISTED ] 4 OFS4 NFPA 4 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. in order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and proectiorisfrom the end of the pipe to the groove All loose paint, scale, dfr1 chips, grease, and rust must be removed prior to installation, Failure to take these impotiarri steps may result In improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used, ( For Additional Informatlar, Contact (800)325-4467 wwwbuiimoosetube.com O Cr From Canada Call (800) 882-4666 saiesbuIJmoosetube.cam 18190aksoioad *I1eI4M0 G4M0 nr,WA (0snAZ oaffar.flc Mao* 63017 utl ADVANTAGES OF BULL MOOSE TUBE' EODYTHREAD 40 Is a lightweight replacement for • Has a Corrosion Resistance Ratio of 14, Sche&fe 40 that has a Corrosion • Has a pressure rating of 300 psi, Resistance Ratio of t,. • Is lighter weight than Schedule 40, Is approved by Factory Mutual and listed by Underwriters Laboratories, Is produced in accordance to ASIM A135 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fi1tJrsçs couplings, and valves Is produced from steel with excellent properties of strength and threadabi111y, Can be used In wet, preaction, and deluge type sprinkler systems, Can be hot dipped galvanized to meet FM's requirement for dry systems Offers lower freight costs Supplied with EDDY GUARD U MIC preventative coating cus LISTED A?PL1WO NFPK •'='-. EDDYTI-fREAD 40 SPECIFICATIONS NOMINAL PIPE OD ID WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LBJFT WEIGHT SIZE 1 51295 1O83 tOO 1A65 1460 70 14/4 150 iA16 500 2070 2,754 51 11/2 t900 1.654 t' 01) 2.547 3,468 44 ZaT5 2,123 1100 31-100 4.842 30 ew Peri ILlfrorrr PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to instalietion, In order to providu a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove All loose paint scale dirt chips grease and rust must be removed prior to installation. Failure to take these important steps may reeutin improper coupling assembly, causing leakage. Alsq check the mariufacture(s instructions for the specific fitting used. For Additional Information Contact (860) 325'4467 wwwbulimoosetube.com Or From Canada Call"(860) 881.4666 salesebuilmoosetube,com U IereCaronad Ceusff4M0 0Erd,MO LncWA CmGmrxkAZ O41JX Mur Oft 63017 - 5 B%Mow Tuber EddyfitO is a fittwa9 threadablé pipe mantñactued in NPS r tPwoph 2'. Eddyfile Is a truly unique product within the fire protection industiy. This product has been en9inecred to provide tower cost fire protection systems without compr0mi5i09 service life, adequate wall thickness, or standrd outside diametec ddytite is manufactured to meet the requirements of AS1M A135, and A795 sped ttons. This pipe product has been fully approved by Factory Mutual, and fisted by Vride,writers Laboratories (for LLS and Canada) for use in fire protection systems with a working pressure of 300 psi or 'ess, c®us LISTED 4owsA NFPK 6 ADVANTAGES OF BULL MOOSE TUBE° EDDVLITEe Standard outside diameter, unlike some other IiØ1twall threadable pipe products. Lighter inweightthan Schedule 40. Superior burst strength and corrosion resistance ratio compared to other 11ghtwa threadable pipe products. 'Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplinqs fittings and valves. Freight savings. tower sprinkler system costs without compromising service life, Better hydraulics than Schedule 40, lAtriJ thickness and welght close to Schedule 30; compare to other ligfmtwail threadabie water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) - I 777M NOMINAL STANDARD INSIDE UL UL WEIGHT - WATER BUNDLE PIPE SIZE (JNJ 0D (IN) DIAMETER (IN) THREADED UNTHREADED PER fl FILLED SIZE 1,315 1.137 0113 7,47 1.260 1.700 91 1.660 1,462 0.08 6.73 1.617 2,364 61 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2,375 2,177 ,.L 4.31 W7 4,30,27 crrr Ce uatwr wolt PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove All loose paint, scale, dirt, chips. grease and rust must be removed prior to installation. Failure to take these Important steps may result In Improper coupling as5emNy, causing leakage. Also check the manufacturer's instructions for the specific fitting used. ( * For Additional Information Contact (800) 325-4467 wwbuI1moosetube.om Or from Canada Cat (800) 882-4666 sates@buflmoosetube.com 10rban,4 CefirfrjM0 G&,M0 Kw4wk Cwa&in*.Z 0e11alX rhawrwoH 63017 c®us LISTED [i;] ho MFPK "===— ADVANTAGES OF BULL MOOSE TUBES EDDY FLOW Certified toASTM A139 and A795 Type F, Grade A. FM approved for roll grooving and welding for use in wet systems Iii Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preartlon, and deluge type sprinkler systems. Lightweight '-saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psI. Can be supplied roil grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD II' MIC preventative coating. NPS O.D. EDDY FLOWS' EDDY FLOW WEIGHT WATER FILLED BUNDLE SIZE (JH) (ID) iR PER FT. WTI 5J7 14/4 1.660 11530 1.98 1.222 2,019 61 11/2 1.900 1,728 3.44 1.644 2.660 61 2 2.375 2.203 2.78 2.330 3.982 37 24/2 2.675 2,705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4.500, 41 I 4,960 .0 19 Cmt ui PIPE PREPARATION For proper operation, all pipe surfca should be cleaned prior to installation, in order to provide a teak-tight seat for the gasket pipe surfaces should be he from Indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, ctiedc the manufacturers instructions fOr the specific fitting used, (6'~ For Additional Information Contact (800) 3254467 wwvThullmoosetube,com Or From Canada Cafl (800) 882.4666 salesbuIlrnoosetubecom 1519 Jrion hfieLLMO' GrauLMO cw&sidAZ O&,TX Maswvou 63057 iFA Bull Moose Tube's' eddy FlOW' is a specialty engineered replacement for Schedule l0 offering better flow characteristics while providing design flexibility, This product Is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it Is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore. Eddy Flow's' larger ID provides an opportunity for downsizing and further cost savings. Buii Moose bnItrEddy'i ADVANTAGES OF BULL MOOSE TUBE ULTRA EDDY6 a versatile product that can be Certified toASTM A15 and A75 Type E Grade A. roll grooved, welded, and used wfth FM approved for roll grooving and welding for use In wet systems. pressfit* Ptoducts. UL listed (for (14 and Canada) for joining by welding or by fisted rubber gasketed fittings for use in wet, dry, preaction, and deluge We sprinkler systems. Lightweight saves shipping costs offers easier handling. MullIdImensionO, Can be used with all Schedule 5 approved roll grooved, welding and Pressfit Products for pressures up to 175 psi. Oetigned to generic Schedule tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger 10 than other products on the market today, Ultra EWoffers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings Can be hot dipped galvanized to meet FM's requirement for thy systems. p NP$ 0D. ULTRA ULTRA EPD WEIGIIT WATER BUNDLE (IN) (IN) EDDY' 00) cllRt PER FT FILLED WK SIRE 11315 1.201 2.17 AS 1.353 91 11/4 s,00 1,546 lAD 1.107 1.020 61 1.1/2 1.600 1.786 Iii 1274 2.360 61 2 2375 2.261 100 1604 3,344 37 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation, in order to provide a leak-tight seat for the gasket, pipe surfaces should be he from Indentations and prolectlorrs from the end of the pipe to the groove All loose paint, scale dirt thrps. grease, and rust must be removed prior to installatIon. Failure to take these Important steps may result in improper coupling c LISTED I assembly, causing leakage. Also check the manufacturer's instructions for the specific fitting used. AMM I I ForAdditiorral Information Contact (800) 325.4467 wwbuiimoosetube.com Or From Canada Calk (800)882 4666 sales@builmoosetube.com NFPA '' j ,. .. cefidMo 0raktM0 (are,W4 caa&a,thAz Deffa1X Ma&iry0I4 65017 8 c€)us LISTED [i;] 4oM NFP - NPS (IN) 11F4 1-10 2 2-1/2 315 1.660 1.900 2.375 LD.6n) 1.201 1.546 1.786 2.261 ULTRA EDDY' *40çb4 0.868 1.107 1.274 1.604 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 1.600 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2203 2.705 3.33.4 4310 EDDY FLOW Ea"Miftwo 1.222 1,444 2.330 2.809 3361 41968 2.019 2.860 3.982 5.299 7.144 11.290 C.RR. 1.98 3.44 2.78 1.66 100 1100 1.315 1.660 2,375 2.875 3.500 4.500 1.497 1.442 1.682 2.157 2.635 3260 4.260 SCHEDULE Empy?tb1f 1410 1.810 2.490 2440 3.530 4.340 5.620 10 idq*ft 1420 21518 3.053 4.223 5.993 7.957 11.795 IM 15.27 9.91 7,75 627 4.92 3.54 2.50 MW 1.315 1460 1.900 2.375 1.137 1.482 1.717 2,127 EDDYLTE 1.260 1.617 1.907 2.617 edV*lMt) 3,700 2.364 2.965 4.230 0113. 0.09 0112 0.16. 1.295 1.650 t900 2.375 EDDYTHREAO 1.083 1.418 1,645 2.123 400 Epiywb/f 1.461 2.070 2.547 3.308 W41b/f 1.860 2.754 3.468 4.842 CJt& 1.00 1.00 1.00 1.00 o.j) 1.315 1,660 1900 2,375 2.875 3500 4,500 1,049 1380 1,610 2,067 2,469 3068 4026 SCHEDULE Et 13J/M $,68D 2274 2,720 3860 5.800 7580 30800 40 2,055 2,918 3602 5,114 7,975 10783 16310 CR4.P0...00 ,104 1.00 1100 3.00 1.00 ('f For Mdoria1 tnformaton Contact (800) 325-4467 wwbuflmoosetube.com Cia,L, Or From Canada (aft (800) 882.4666 sFesbuflrnooetube.com B, C1I1dM0 4ea,M0 t* .WA Cosa&MAZ DeHiX Mur3Q1 63637 9 NPS PIPE TYPE WEIGHT PER FOOT PIECES PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE WJRAEDO? 0.868 91 1,659 1,896 11975 SCHEDULE ID 1.410 93 21695 31079 31208 EDonrrE' 1,260 91 2,408 2,752 2,867 EDDYTHREAD 400 1.461 70 2,146 2,454 2,557 SCNEDULE40 3.680 70 2,470 2,822 2,940 ULTRA EDDY* 1.107 61 1,438 11621 1,688 EDDY FLMO 1,222 61 1,565 1,769 1,664 11/4 soioiii ø 1.830 61 2,319 21650 2,760 EMM 1.617 63 2,071 2,367 2,466 ED7HREA040 2.070 51 .,217 2,534 2,639 SCKIDULE 40 2.270 51 2,431 2,778 2,594 - W.TRAEDOY' : 3.274 63 1,632 11855 1,943 EDDY FLOW 1.844 61' 21352 21700 2,832 1 1' /2 SCHEDULE 10 2.090 61 2,677 31060 3,187 EDDYUTE* 1.967 61 2.520 2,880 31000 WDYWRED40 2,547 44 21353 2,690 2,802 V-.HEDLXF 40 : 2.720 44 21513 21872 2,992 ' ULTRA EDOY 1.504 - 37 1,246 1,424 1,484 EDDY FLOW' 2 330 37 1 530 2,069 211,55 2 SCHEDULE 18 2,640 37 2.051 2,344 2,442 EDOYUTL'. 2.617 37 2,033 2,324 2,421 EDDYTHREAD4O' 3.308 30 2,084 2,382 2,461 j. SCHEDVLE40 3.660 30 2,306 2,535 7,745 2.809 1.0 2,022 21107 21t2 SCHEDULE 18 3.530 30 2,224 2,542 2,648 SCHEDULE 40 5.800 3.654 4,376 4,350 r !0' FLOW' 3.361 1,341 3,533 11595 3 SCHEDULE 10 4.340 19 1,732 3,979 2.062 - SCKEDULE4O 7.580 . 3,024 3,496 31601 - -4- F , F/ FLOW' , 4.968 1,982 2,265 2,364 4 SCHEDULE 10 5.620 19 2,242 2,563 2,670 - SCHEDULE 40* 30.800 4,309 4,925 5,130 ~ME To 91M 14 1,951 2,229 2,322 s _] sctEi.uuo 16.940 7 2,490 2,846 21965 UL Moon= In CMPANV 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325'41467 FAX: (636) 537-2645 www.bullmqosmbe.cqm seIe©buIImoosetub.corn Bull Moose Tuba EDDY FLOW Steel Pipa Joined by Threading, Handing or Campreiian1Grooved Couplings Max Zona of Influence Load (Jaw) Iba. Max. Trarvaraa and 4-way Brace Spafng (It.) According to I'ILF for the 2006 & 2089 IBC C ASC 7.05 ) & Cp for NFPA13 ahown In BOLD TYPE Pipe anavaraa Brace Pfl9' Size 201t. 26 ft, 301t. 301t. 40ft, 0.25 0,50 0.75 1.00 1 1,25 11,50 1,751 2.00 1 2,25 2,50 12,751 3.00 1114 136 109 89 76 64 40 40 37 32 1 29 26 24 23 21 20 19 18 1112 232185 152 130 109 40 40 40 35 31 29 27 2523 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 256 40 40 40 40 38 32 30 26 26 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 ~25 6 25 24 4 1544 1235 1012 857 726 40 40 40 40 40 37 34 32 30 9 28 26 Hull Macac Tuba EDDYTHREAD 40 Steel Pipe Joined by Threading Bonding or Compreaaion/Grooved Coupipn9a MaxZone be, of Influence Wad 17 Max, Transveree and 4-way Brace Spacing (ft.)" According to LF for the 2006 & 2009 IRC (ASC 7-05) & Cp for NFPA.13 shown in BOLD TYPE Pipe 'rranvcree Brace Spacing' Size 201t. 25 ft. 30 ft, 35 ft 14811. 0.25 0.50 0.75 1.60J 1.25 [1.50 1.75 2.00 2.25 2.50 2.75 f 3.00 1 1119 85 78 1 67 55 40 40 36 31 J._28 25 24 22 21 20 19 [ 18 1114 218 175 143 123 1 103 1 40 40 40 35 31 1 28 26 25 23 22 21 I 20 11/2 $12 251) 205 L 175 I 147 40 40 40 31 33 I30 28 26 25 23 22 j_21 2 516 414 339 I 291 2431 40 40 40 40 36 I 33 30 29 27 26 24 I 23 cus LISTED (] 4 Qi* NFPX •==-. ( FOr Additional Information ft (800) 325-4467 wwwbullmoosetube.com . Or From Canada Cat (800) 8824666 saIesbufimoosetubecom thrstafildM8 GEraM0 I*W4 c&aridAZ O&Ia1X Masuç0 63017 11 MechanicaIi STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a 'holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe GD. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections, NOTE Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- bu:ylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe, Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I' in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating; Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket-. (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical: services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrite Nitrile (Orange color code). Temperature range —20°F to +I80°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved Date www.vlctaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF VCTAULC COMPANY 0 2011 vlcTAIJLIC COMPANY. ALL RIGHTS RESERVED. EVJJ Para__________ Jtauu.cr CARBON STEEL pgp - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings cannot be matec to one another to achieve cross connections. lob jrs m½s m4rsa 8 tz4 ' 2 ½ (a) P 920¼ 500 .50 2.00 2.53 - .61 5.35 2J5 3.1 50 15 3450 38.1 51 64 41 136 70 1,5 920¼ 500 1.50 1.97 2.53 1.61 5,35 2]5 3,1 - 20 3450 38.1 50 64 - 41 136 70 - 1.5 1 a 920¼ 500 1.50 1.85 2,53 1.61 5.35 2.75 3,0 - 25 3450 383 47 64 - 41 136 70 1.4 IA (a) ' 90"l 500 1.75 2.05 2.75 3.00 1.61 5.35 3,00 3.5 -4 3.2 32 3450 44.5 - 52 - 70 76 41 136 76 1.7 1,5 420 500 1.75 203 2.75 312 1.61 - 5,35 3.25 - 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1,7 1.5 21/2 . ½ (a) §n"oN x L 500 1,50 2.21 2.74 1.82 5,64 2,75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - Y4 (a) §Q 9201' 500 1.50 238 2.74 - 1.82 5.64 2,75 3.0 20 3450 38.1 55 70 46 143 70 1,4 - 9201" 500 1,50 - 2.06 2.74 .82 ' 5.64 2.75 - 2.9 25 3450 38.1 52 70 - 46 143 70 1,4 - 1¼ 5(a) a ' 500 1,75 230 3.00 3,25 1.82 6,29 3.00 3.5 3.2 32 - 920 '' , 3450 44.5 58 76 83 46 160 76 1.7 , 1.5 1h 5(a) a . 920i 500 2,00 2.28 3.00 5.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 --- ,- 83 46 159 83 -.'- 1.7 1,6 7 1 ½ )a) 9201' ' 300 1,50 2.22 2.75 . 2.25 648 ---4 3.18 3.9 15 2065 38.) 56 70 - , 57 164 81 18 - , 3/. )a) 300 1,50 2.19 2.75 2.25 6.46 3.18 3.9 20 9201' 2065 38.1 56 70 57 164 81 1.8 - 920N 300 - 1.50 2.07 2,75 ' 2.25 ' 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 - 1¼ (a) P 920¼ 500 1.75 2.30 3.00 3.31 1,92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 15 1½ (a) a '¼ 500 2.00 2.28 300 3.31 1.92 6.29 ,- 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1,6 1,5 3 ½ (a) 923¼ 500 1,50 2,52 3.05 - 2.28 6.15 2.75 3,4 - 80 15 3459 38.1 54 78 58 156 73 15 34(a) 923¼ 500 1,50 249 335 - 2.28 6.15 2.75 3.4 20 ' 3450 38,1 63 78 58 156 70 , 1.6 1(a) 500 1.50 2.38 3.06 2,28 6.15 2.75 3.3 25 ' , 3450 38.1 61 78 58 156 70 1.6 - 1¼(a)ta 9z0¼ 500 1.75 2,55 3.25 3,56 2.28 6,15 3.00 3.8 3.7 32 (b' 3450 44.5 65 83 90 58 156 76 1.8 1.8 1½(a)i-a 920N 500 - 2.00 2.78 . 3.50 3.56 .-.- 2.28 6,15 325 ..........4. 43 3.8 40(b) 3450 50,8 71 39 90 58 156 83 1.9 1.8 2 (a) a 920¼ 500 2.50 2.75 350 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63,5 70 89 90 58 172 99 23 2.1 31h x 2 920½ 500 2.50 3.00 1 3,75 2.44 6,72 3.88 ] - 3.8 90 50 3450 63.5 76 95 62 171 99 1,8 TABLE CONTINUED ON PG. 3 " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), S Available with grooved or female threaded outlet, Specify choice on order. S Center of run to end of fitting. It Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order For 76.1 mm threaded outlet, specify 2½' BSPT clearly on order, § Jds approved for fire protection services El -PCB approved for fire protection services 0 Approved for use in Chna by Tianjin Approvals Company, F-Y-~~J r-r- Z 7-11 t5- ~ I GROOVED OUTLET F i i~ FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm www.victaulic.com /ctauIic VICTAUJC IS REGISTERED TRADEMARK OF VIcTAuLIC COMPANY, 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED, 11.02.2 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x ½0/50 x 15mm. through 8 x 4/200 x 100mm CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 9201'I housings cannot be mated to one another to achieve cross connections. Will)0 ci - dDI ira2m rovr js TABLE CONTINUED FROM PAGE 2 4 ½(a) 920N 500 1.50 303 3.56 - 2.59 7,01 2,75 3.7 100 15 3450 38,1 77 90 68 178 70 1.8 3K (a) 920N 5001.50 3.00 3.56 - 2.69 7.0-1 2.75 3.7 20 3450 38] 76 90 68 178 70 1,8 1(a)a 920N5001.51 2.88356 2.69 701 2-75 3.6 - 25 3450 38.1 73 90 68 178 70 1.8 - 1¼1a)ta 920N 500 175 3,08 3,78 400 2,69 7,01 3.00 4,0 36 32 (b) 34510 44,5 78 96 102 68 178 75 1.9 1.8 11/' 920N 500 2.00 3,28 400 4.00 2.69 7.01 3.25 4.2 3.9 401,0) 3450 50.8 83 102 102 68 178 83 2,0 1.9 2 (a) to 92014 500 2.50 3.25 4.00 4,00 2.69 7,01 3.88 5,0 4.6 SO 3450 63.5 83 102 102 68 178 99 2.3 2] 2,6a) 920 500 27 288 400 400 29 734 463 58 50 55 3450 59.9 73 102 102 68 186 116 2.6 2,3 76,1 mm 920 50] 75 288 400 259 734 4,63 5A 3450 69.9 73 - 102 68 186 , 118 2.9 3)a)t 920 500 3.50 3.31 4,50 - 4.12 - 2,69 7.73 4 5.12 8,4 5.4 80 , - , 3450 88.9 84 114 105 68 196 130 3.8 2,9 1080 1/ (a,s Y. 920F 00 7 308 378 253 764 05 50 32 , 3450 44,5 78 - 96 - 67 194 78 23 - 1½(a(a 9201\1 500 20 ' 3.28 4.00 2.63 ' 7.64 5.25 5.0 40 , 3450 50.8 83 102 , - 57 194 83 2.3 - 2(a) 9201'] 500 2,50 3.25 4,00 2.63 754 t.00 4.0 50 - 3450 63.5 83 - 102 , 67 194 ':02 1.9 76.1 mm 920 500 2,75 2.88 4,00 4,00 2.63 7.64 ,29 8.0 7.8 3450 69.9 73 102 102 67 194 '09 3.6 35 3(a) 920 500 3.50 ' 3.31 4.50 4.50 2.63 7.63 .88 6.8 6.5 80 , 3450 88.9 84 114 11467 194124 3,1 3.0 5 , 11/2(a)t 920 500 2.00 4.03 4,75 4.75 3.16 9,70 0.69 7.4 7,6 125 0 3450 50,8 102 121 121 80 246 94 3.4 3,4 2 it 920 00 20 400 475 - 475 316 970 438 82 80 50 - 3450 , 835 102 , 121 , , 121 - 80 246 III , 3.7 3.5 214 (a) 920 500 2.75 3.53 4.75 4.75 3,15 9,70 4,63 8.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76-J mm a 920 500 , 3450 2.75 69.9 3.75 95 - 4,75 121 3.16 80 9.70 246 4.63 118 - 8.0 ___3.6- 3 (a) t 920 500 350 3.81 5.00 4.63 3.16 9,70 5.31 8.4 8.8 60 3450 88.9 97 127 118 80 246 '35 3.8 4.0 2 x. 920N 500 250 3.75 4.50 3.17 800 3.88 8.0 , 50 3450 63.5 95 114 - 81 203 99 3.6 920 Soo 3.50 3,81 5.00 3.00 9.46 ' 531 8.0 80 3450 88.9 97 127 76 240 '35 3.6 - 'TABLE CONTINUED ON PG. 4 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications, @ See page 7for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" cleahy on order, (b)For 76,1 mm threaded outlet, specify 21/2' BSPT clearly on order. Vds approved for fire protection services LPCB approved for fire protection services 0 Approved' for use in China by Tianjin Approvals Company www.victauflc.com j(ctauIac' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2017 VICTAUUC COMPANY. ALL RIGHTS RESERVED, REV)1 11.02.,3 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS T '! T Z1 Fl .•1rj ' P 4-Z 4 TABLE CONTINUED FROM PAGE 3 139.7 x T920N - 30 823 3 84 209 s23 40 3450 50 8 96 114 - 500 2.50 3.75 4.50 3.30823 3.88 9.0 -- 50 345063.5 95114 84 20999 4, - 1 W 6 1¼(a) 500 1.75 4,43 5.13 5.13 3.79 9.15 3.25 5,1 4,8 150 32(b) 92. 3450 44.5 112 130 :30 96 232 53 2.3 2.2 GROOVED OUTLET 920N 500 2,00 440 513 5,13 379 915 3.25 54 51 40(b) 3450 50.8 112 130 130 96 232 83 - 2,4 2.3 2(a) ta WON 500 250 4.38 5,13 5.13 3.79 9,15 3,88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 g p - _-I _______ 2½ 500 2.75 4,01 5.13 5.12 3.69 0,51 4.63 83 7.6 ______ r-i 920 3450 69.9 110 130 139 94 267 118 3.6 3.4 V 500 2.75 4.15 5.21 3.69 10,51 4.63 8.4 T 76,, mm 920 3450 69.9 105 132 94 267 118 - 3.8 - - 3(a)t 920 50Q 350 431 550 53 369 1051 531 99 84 w 80 , 3450 88.9 110 140 130 94 267 135 4.5 ,3.8 4 () tin 500 4.50 3.81 5.75 5,38 3.69 10.51 6.25 10.1 10,1 100 920 3450 1143 97 146 137 94 267 159 4.6 4,6 FEMALE THREADED OUTLET . - - -- + - - - . - - - 1½ N (a) 2 500 2,00 441 ,13 3,63 9.40 3.25 7.8 - 40 3450 50.8 112 130 92 239 23 3.5 2(a) . 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 Provides a direct branch connection at 50 920 3450 63.5 , 111 130 - 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 ' 5.50 5.13 3.63 9,40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 43 4.3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 531 8.1 14.0 A pressure responsive gasket provides 80 -. 3450 88.9 110 140 130 92 239 - 135 3.7 , 6.4 the seal iorl 020 500 4.50 4.45 - 5,38 3.63 9,40 612 - 10.0 3450 114,3 113 , 137 92 239 155 45 Request Publication 11.03 for 5004.503.81 5.75 3.63 9.40 625 8.0 Mechanical-T cross assemblies 920 3450 114.3 96.80 46 92 239 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HOPE pipe t Center of run to end of fitting. Sizes from 2 x ½750 x 15mm 8 Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4/200 x 100 mm. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (h)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order, § Vds approved for fire protection services o LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use In China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections.. www.victaulic.com iiiAtauIic vIcTAULIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 02017 VICTAULIC COMPANY, ALL RIGHTS RESERVED 11,024 REt1j4 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-Tb Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS .3 .: r2 43A5t 535 P-1 W-1-4 :0% 4 7~rl !-svlrek 4liI' FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11,03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm 165' X 2 11 5 .1 920N 500 1.50 3.88 4.56 3.79 9.34 2J5 8.0 3450 38.1 - 99 116 - 96 237 70 3,6 - 1¼a 9 N 500 1.75 443 - 57 3 3.79 - 9.34 3 .25 8.4 32 3450 44,5 113 130 - 96 237 33 3.8 - 1 1/2 Kal t 920N 500 2.00 4.41 5.13 0.13 3.79 9.34 3.25 8,4 5,4 40 3450 50.5 112 130 130 96 237 33 3.8 2,4 2(a) t 920N 500 2.50 438 5.13 5.13 3.79 9.34 ' 3.88 8.5 6.0 50 , 3450 63.5 111 130 130 96 237 99 3.9 2.7 mm 76 1 920 500 2.75 4.01 5.13 5.21 3.63 10.51 - 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3,9 3.4 (a) t o 920 500 350 4.311 550 51 363 051 53 02 84 80 _ , 3450 839 110 140 130 92 267 35 4.6 3.8 920 500 450 ' 3.81 538 3.63 1351 625 10,5 8.4 100 3450 1143 97 146 137 92 267 159 4.8 3.8 8 2)) 920 69 625 481 1442 450 16 116 200 53 , 3450 699 - 138 157 159 122 316 114 5.3 5.3 2,Ya) 920 500 2/5 5,07 6.19 6.19 4.81 1242 450 11.6 1 6 65 , - 3450 699129157 157 122 316 114 5.3 5.3 761 mm 920 500 475 525 625 481 1242 456 1 4 3450 69.9 133 - 159 122 316 116 - 5,3 3(a) ta 920 500 3.50 5.31 6,50 6,50 4,81 12,42 5,31 12,6 11,6 80 , 3450 88.9 135 165 165 122 316 55 5.7 5.3 4 (ai t 920 500 4,50 4.81 6,75 6.38 4,81 12,2 6.25 15.3 12,5 100 3450 114.3 122 171 162 122 316 139 6,9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are availaCle to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clear y on order (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianj!n Approvals Company. IMPORTANT NOTES: Style 920 and Style 9201\1 housings cannot be mated to each other to achieve cross connections. www.victauIiccom A~C__tauhor VICTAULIC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY, © 2017 VICTAIJLIC COMPANY, ALL RIGHTS RESERVED. Isk REV_" 11,025 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanicall-r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalTa fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values I Values for flow of water at +60F/+1 °C are shown in the table below. 0 Formulas for 4 ,K Values: AP = Q2 Where: - p = Q2 Where: Q = Flow (GPM) - K 2 Q = Flow (m3/hr) AP = Pressure Drop (psi) AP = Pressure Drop (Bar) Q = C x ç = Flow Coefficient Q = K x K = Flow Coefficient Exaggerated for clarity Equwalent Length Outlet Sue ScI of OUTLET SIZE -- ... 40 Caffion Steel (C 120)1 F Pipe I- C,/K, Values - ½ 0.840 2 11 15 213 . - -9,4 3/4 1,050 4 16 20 267 . - 13.7 1.315 — -- - ----- 8 -' - 21 25 33.7 - - 1.8 1 ¼ 1.660 / 6 50 48 32 427 42.9 41.1 1½ 000 53 -. 53 40 983 45.4 45.4-- 2 2.375 9 10 . 112 ]o4 - 50 60.3 96 89.1 2½ 2,875 20 12 h 119 - - 50 - -. 65 73.0 102 - 128.5 - 3.000 76.1 mm 16 161 76.1 138.1 - - 3 3.500 - 14 15 V 249 237 80 . 88.9 - . - 213.4 203.1 4.500 20 1 421 401 - -. 100 114.3 , 3608 343.6 Hazen-Williams coefficient of friction is 120, Pipe with a wall thickness of 0.165in14,2mm, 1 FireLock Innovative Groove System (IGS) outlet www.vktaullc.com iJ(ctauIicr vlcrAuLIc Is A REGISTERED TRADEMARK OF VITAULl 82 COMPANY. 2017 VICTAULIC COMPANY ALL RIGHTS RESERVED, 11.026 REVM CARBON STEEL PIPE 11.02 Mechanical-Tb Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. . W-4 . . '5 21/2 -6 2.875 - 6625 Al 10 40 400 400 400 290 65- 50 73.0 - 168,3 2755 2755 - 2755 1999 21/2 -4 2.875 - 4.500 A OF - 300 - 300 300 290 65-100 730-114,3 2065 2065 2065 1999 21/2-4 2.875 -4.500 At SF 300 300 300 290 65-100 73.0-1143 2065 2065 2065 1999 6 6.625 34 10 300 300 250 290 50 168.3 2065 2065 1724 1999 6 6,625 '040 300 300 300 290 150 168.3 2063 2065 2065 1999 8 8.625 21/2 10,40 400 - - 200 219,1 2755 ' 8 - 8,625 34 - 10 - 300 250 200 219.1 - 2065 1724 8 8.625 3040 300 300 200 219,1 2065 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe, OF refers to Listed/Approved Dyne-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation 232 362 1599 2496 232 362 1599 2496 232 362 1599 2496 232 362 1599 2496 232 362 1599 2496 145 1000 145 1000 45 1000 VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4. 87100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/345OkPa. The Style 931 Vic-Tap IF Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 4t 57125mm, 67150mm and 87200 mm diameter pipe. The Style 931 comes with a 2 ½'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. P7 For more information, refer to publication 24.01. www.vktaulic.com 'jctauiic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-04 11.027 STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at wwwvictaulic,com, WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com '%_,4tauIc' I.02 480 REV N UPDATED 12/2017 VICTAULIC IS REGISTERED TRADEMARK OF VICTAI.JLIC COMPANY. © 2017 /iCTAULIC COMPANY. ALL RIGHTS RESERVED. 11.O2L ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwal), Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 1001 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para___________ Location Date Approved Date www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. O 2009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. JtauIic 10,521 DIMENSIONS IRS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 1 1/4 ½ 1 /e 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 1/6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 4-- . - 1 1/6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 - 55.4 27.9 98.3 65.0 0.54 1½ ½ 13/16 1.42 1.95 - 1.22 4,08 2.56 1.2 40 15 30.2 .4- 36.1 49.5 31.0 103.6 65.0 0.54 '/4 1 3/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 650 0.54 -4- - 1 1 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 ½ 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 650 0.59 3/4 1 3/16 1.64 2.19 1.46 - 4.60 2.56 - 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 - 0.64 1 13/, ' 1.88 - 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 - 65.0 0.68 21/2 ½ 1 3/16 1.91 - 2.44 1.71 5.40 2.56 - 1.6 65 15 30.2 , 48.5 62.0 43.4 137.2 - 65.0 - 0.73 - ~ 1 146 - - 1.89 2.44 - 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 - 65.0 0.73 1 1 3A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm 1/2 X 13/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1 /o 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 1397 65.0 0.73 ----4- . 1 1146 2.13 2.79 1.71 5,50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 FireLock OutletT STYLE 922 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com ictsu IC VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 6 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. x./ic 1052,.2 REV.G IP$ CARBON STEEL PIPE. HOLE CUT PRODUCTS 10.52 FireLock' Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com \j 'tauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RELG 1O.923 FireLoW OutIetT STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 /ictaulie VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10,52 U fl n SMITH .--, COOPEIW I NTERNATIONAL Ductile Iron Threaded Fittings [Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP cULus Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 c®us APPROVIM Fig. 35E 3-90° Elbow USTED Size in Part N b umber A in Packing weight lb inner Master 1/2 35E 3004 1713 100 200 0.2 3/4 35E 3006 131 70 140 0.3 35E 3010 1.50 40 80 0.5 1-1/4 35E3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 1 18 36 1 1.1 2 35E 3020 225 10 20 16 2-1/2 35E 3024 1 2.70 1 4 1 8 3.2 Fig. 35RE3 -.90* ReducIng Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1,36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 11/4x1/2 35RE3012004 134 1.53 35 70 05 1-114x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 18 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1,75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1,82 1.88 18 36 1.0 2x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2x1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-114 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 358E3020014 2.02 2.16 10 20 1.5 2-1/2x1-1/2 35RE3024014 2.16 2.51 6 12 2,2 1 2-1/2 x 2 35R83024020 2.39 2.60 6 12 2.5 10 Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 160 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 3SF 3010 1.13 40 80 0.5 1-1/4 - 35F3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35F 3-45° Elbow Fig. 35T.3 - Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1,13 80 160 0.3 3/4 35130O6 1.31 30 so 0.5 1 3513010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 20 1.1 1-1/2 3573014 1.94 10 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 I p 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • www,mirhcooperom Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1/2 35R73006004 1.20 1.20 1,2260 120 0.4 11/2 35R73010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x3/4 35813010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35813010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 358T3010006010 1.50 1.45 1.50 25 20 50 0.7 0.8 1-114x1/2 358T3012004 1.34 1.34 1.53 40 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 1'1/4/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1I/4x3/4x1-1/4 358T3012006012 1.75 1.62 1.75 ' 20 40 1.0 1-1/4x1 35813012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 11/4xlxl 358T3012010010 158 150 169 20 40 09 1-1/4xlx1-1/4 35813012010012 1.75 1.69 1.75 15 30 1.0 1-112x112 358T3014004 1411.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35813014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 358T3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x 3/4 35813014006 1.52 1.52 1.75 16 32 1.1 -1-1/2 x 3/4 x 1 1/4 35RT3014006012 194 166 188 20 40 11 1-112x3/4x1-1/2 358T3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 358T3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35813014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1 x 3/4 358T3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35813014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-112 358T3014010014 1.94 1.80 1.94 12 24 ' 1.3 1-1/2x1-1/4 358T3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 11/2x11/4x3/4 35RT3014012006 152 145 175 16 32 10 1-1/2x1-1/4x1 i 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35813014012014 1.94 1.88 1.94 14 28 1.4 2 x 112 35RT3020004 1.49 T. 1.88 10 20 1.5 2x3/4 35813020006 1.60 1.60 1.97 10 20 1.6 2x1 35813020010 173 1.73 2.02 8 ' 16 1.7 2 x 1 x 2 358T3020010020 2.25 2.02 2.25 8 16 1.9 -2x1-1/4 35R13020012 1 1.90 2.10 8 15 1.9 2x1-1/4x2 358T3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 358T3020014 2.02 2.02 2.16 8 -16 2.1 2x1-1/2x1/2 35813020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 732 1.97 , 10 20 1.4 2x1-1/2x1 35F13020014010 1.73 1.65 2.02 8 16 1.5 2x1-112x1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 358T302004014 2,02 1 1.94 2.16 1 8 16 1.8 c®vS <~> APMOVM Fig. 35RT3 - Reducing Tee LISTED Fig. 358T3 -Bull Head Tee Size in Part Number A in B in C in Packing , Weight I lb I I Master 3/4x1 ' 35B13006010 1.45 1.45 1.37 30 60 0.6 lx1_1/4 35BT3010012 167 _167 158 20 40 09 Ix1-1/2 35913010014 1.80 1.80 1.65 15 30 1.0 11f4x1x11/2 35BT3012010014 188 180 182 15 30 12 1-1/4x1-1/2 , 35913012014 1,88 1.88 1,82 15 1 30 1.3 1_1/4x2 35BT3012020 210 210 190 _10 20 16 1-1/2x1-1/4x2 359T3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 358T3014020 2,16 2.16 2,02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • swwsmthcfiopr.com 112 Fig. 3503 - Straight Coupling with Ribs c®uS <e> APPROVED LISTED Size in Part Number u er A in Packing - Weight lb Inner Master 1/2 35CP3004 138 200 400 0.1 - 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 3CP3012 200 35 70 05 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 30 1,2 35CP3024 3.00 9 18 2.2 Size in Part Number [ A in Packing Weight lb Inner I Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 I 35SP3010 [ 1.25 200 400 0.1 1-1/4 35SP3012 [ 1.37 1 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35RC3 - Hex Reducing Coupling Size Part Number A in Packing -- Wefghi lb Info! Master lx 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 80 0.4 1-1/4x3/4 35RC3012006 2.06 - 40 0.6 2x1 (not hex) 35RC3020010 1 2.81 1 20 40 1 1.0 Fig. 35HB3 - Hex Hushing Size irt Part Number 1.a A _____in ______ Packing Weight lb Inner __ Master 1 x 1/2 35-1B30100Q4 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0,1 1-114x1 35H33012010 1.19 90 180 0.2 1-1/2x1 35H83014010 1.25 75 150 0.4 1-1/2x 1-1/4 35HB3014012 1.25 75 150 0.3 2x1 35HB3020010 1.38 40 80 0.6 2x1-i/4 35HB3020012 1.38 40 80 0.6 11 2x1-1/2 35H93020014 1.38 40 80 0.6 Fig. 3503 - Square Head Plug Fig. 35U.3 - Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35L)'3010 2.19 20 40 1.0 1-1/4 35U3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U020 1 3.12 1 6 12 2.4 113 SN/UTH-COOPER 1NTERNAT1ONAL • TOLL FREE 1-$00766-0076 9 FAX (323)890-4356 0 wwsrnthcoopercom C@US APPROVED <e> LISTED Size in a u r Part Number A in Packing Weight lb Inner Master 135X 3010 1.50 20 40 0.9 1-1/4 35X3012 175 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 1 3X3020 2.25 6 12 2.8 Fig. 35X 3- Cross Fig. 35R13 - Reducing Cross Size in Part Number T A in B in Packing Weight lb inner I Master 1-1/4 x I 35RX3012010 167 158 15 30 1.2 1-1/2x1 35RX3014010 1.80 165 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number b A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-114 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0,5 2 35C 3020 1.45 25 50 0,8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 3580 - Hewn Clamp Size in Part Number A in Packing Weight lb Inner Master 3/8r 359C3003 0.75 100 200 0.3 1/2 358C3004 0.75 80 -. 160 0.5 SMITH-COOPER INTERNATIONAL' 9 TOLL FREE I00766-0076 9 FAX (323) 890446 • wwwsmithcooper,com 114 Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYl into the #14 (black) nut driver (pill 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the rut driver spins freely on the SAMMYS, stop drill and remove. 4, The SAMMYS is now ready to receive 1/4' 318", 1/2" or metric all thread rod, bolt stock. (The 1/2' requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maxim umpullout in purlin steel. 911i E1 :i1 Insert the appropriate nut driver into a 318"or 1/2"portable drill. Insert the SAMMYS into the #148W (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", 1,110, MB or metric all thread rod or bolt stock, Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximum pullout in purlin steel, INSTALLATION STEPS -IJJJ INTO CONCRETE: 1 L/sirg an SOS 250 carbide tip bit or a HEX RECEI VER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pro-drilled hole, turn impact'drlll unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 5 The concrete screw is ready to receive 1/4", 3/8", 1/2' or metric all thread rod or bolt stock. (#14SWred nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw, [INSTALLATION STEPS - INTO CONCRETE: 1 1, Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drlll the concrete member to a depth of 2' with a hammer/ rotary hemmer drill set on impact mode. After pre-driiing has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pro-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5, The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener _____ - A4uiM ui1Uii1u11liilii k1i1 OEM MY DMIM—MIN.. The nut drivers were designed with unique spinoff feature which provides a fast and safe Installation each time, When the face of the driver comes into, contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations, pV SAMMYS° FOR STEEL Made with Teksv self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1)2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 02500. Made in the U.S.A. Wafth a ida rie,,anvm(jon al www.itwbulldex.com i - #14 Black Nut Driver Part #8113910 - !A1HI.iIt[I1IiL - ---', 1(4 8024957 DSTR100" 114-20x1" TEKS 3 1510 (20 go.) G36'-20 go 3(16" 25 125 - 117 8025957 DST 100 1/4-14 x V TEKS 3 446 (209a) - .036"-20 91_ 3/16 25 257 114" 8026957 DST 150 1/4-14x1-112"TEKS3 970 (16 go.) - .036"-2G go 3116" 25 125 1/4 8027957 DST 200 1/414x2 TEKS 3 446 (20 go.) edI89a3/16 25 125 j 114' 8030957 7EK500 12-24x1-1/2"TEKS5 3125 (3/16') -- .1881-3/16" 1/211 25 125 F87 8038957 DSTR1 1/420x1 TEKS3 1510 (20ga) 15001475 .036L20 9t 3/16 25 125 .' 3/8" 8037957 DSTR l-1/2"12-24 *1-Il2 TEKS 5 1510 (3/16') 1500 1475 .060"-16 go. 112 25 125 3/8" 8039957 DSTR516 5/16-18 x 1-114' TEKS 3 2200 (20ga) 15001475,036"-20 go 3/16" 25125 ] 3/8" 8040957 DST 10 1/4-14 xl" TEKS 3 446 (20 .036"-20 go 3/16" 25 125 3/8."8077925 DST IO-SS1/4-14x1"TEKS3 446 (20 .036"-20ga3/16"2512] 3/8" 8041957 DST 15 1(4-14 x 1-112" TEKS 3 446 (20 .036'-20 go 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14x1-1/2"TEKS3 446 (20 go.) .036"-20 go 3/16" 25 125 970 (16 go.) 3/8" 8042957 DST 20 1/4-14 x2"TEKS3 446 (20 .036-20ga 3/16" 25 125 3/8 8043957 DST 25 1/4-14 x2-1/2' TEKS 3 446 (20 .036'-20 go 3/16" 25 121 3/8" 8044957 DST 30 1/4-14 a 3" TEKS 3 446 (20 036"-20 go 3/16" 25 125 970 (116 go.) 3/6"8045957 DST S165I16-18x1-1/4 TEKS3150013/16")15001475.125"-1/6" 3/16" 25 125 3/8"8046957TEK 5012-24a1-1(2" TEKS 53125(3/16")15001475.250-1/4' 1/2"-25125 1/2' 8031925 DST 2.0 1/4-14x2TEKS3 446 (20 .188'-3/16" 1/4" 25 12j 1/2" 8033925 DSTRI.0" 1/4-20 x 1 " TEKS 3 1510 (20ga.) .036"-20 go 3/16" 25 125 1/2"8034925DSTR5.16"5/16-18x_1-1/4" TEKS3_2220(20ga.) -.03&-20 725-1 1/2" 8055925 DST 5.16 5/16-18x1-1(4TEKS3 1500(3/16") .125'-118" 3/16" 25 125 1/2 8036925 TEK5.0 12-24x1-1/2"TEKS5 3125 (3/16") .188"-3/16" 1/2" 25 125 "Includes retaining nut SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation , }j$ each time. When the face of the driver comes Into contact with the material you are installing into continue drilling unIt nut dnver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Made with Tks® seIfdrilling fasteners no pro-drilling required. 'Installs into steel range from 20 gauge - 1/2" thicknesses, rn g 'A standard screwgun with a depth sensitive nosepiece should be used to B - - eJ install Teks. For optimal fastener performance, the screwgua should be a " minimum of 6 amps and have an RPM range of 02500. 'Saves time from traditional methods. Reduces installation coats. Quick to install using the Samrnys Nut Driver with an 18V cordless drill/driver. Wtch video domoasfraon at Made in the U.S.A. ,,.. www.ltwbuito'ezcarn 114" 8047957 SWO 100 1/4-14x1"TEKS3 1477 (16 go.) .060"-16ga 3/16' 25 125 114 8049957 I6 T&i 1/42001 TENS 3 - {020ga) 3/8 8050957 SWDIO 1/444x1"TEKS3 1477 (l6ga) .060"-16ga 3/16 25 125 3/8 8080925 SWfl 10-58 1/4-14 x 1 TENS 3 1477 AT-1 6 9a 3/16 25125 j ' 3/8" 8051957 SWO 15 1/444e 1-1/2"1'EKS3 1477 (16ga ,060"-16ga 3/16' 25 125 - 3/8 8052957 SWO 20 1/414x2 TEKS3 1477 (16ga) .060"-16 ga 3/16 25 1251 1 3/8" 8053957 SWD 516 5/16-18x1-1/4TEKS3 2480 (20 go.) ,036'-20ga 3/16' 25 125 8055957 SWORI 1/420x1 TEKS3 1900 (LO 9a.) 1500 1475 ögaW 25 12 $145. ed 3/8" - 8054957 SWER 1-112 • 12-24 * 1-1/2"TENS5 2375 (3/16') 1500 1475 18&"-3/16" - 112" 25 125 - Jt47)ri*er 3/8 8056957 SWOR 516 5/1618x11/4TEKS3 2480 120 ga) 1500 1475 036"-20 ga 3/16 251j tj$$il49i0 3/8 8057957 SWT15 12-24o1-1/7TENS5 2375(3/16') .188"-3/16" 1/2" 25 125 Includes retaining nut Eliminates distortion of threaded rod In sloped roof applications. Accornrodates 3-1/2x 12 pitch. lostalte into angled z-puriin; allows threaded rod to hang plumb. 'Allows 117° deflection from vertical. * Made in the LISA Watch i videO dementtreuion at wwwjvwbulWexcom #14 Black Nut Driver Part #8113910 3/8" 8137957 S11-DSTR 1 3/8" 8268957 SN-TEN 50 12-24x-3/4' TEKS 5, 3220(3/16) 1500 2368(1/2' steel Vertical) 1308(45° off Vertical) 1500 (Vertical) 2281(3/16" HSS) 850(45' off Vertical) 1585(3/16" HSS45" off Vertloal) 1475 035' 3/16' 25 1251 3/16' 1'I2' 25 125 3/16" 112" 25 125 2368(1/2' steel Vertical) 1/2' 8270957 SN-TEN 5,0 12-2401-3/4' 1306(45' off Vertical) TENS 5 2281 (3/16" NSS) 1585 (3/16" i1S545 off Vertical) 'Does not comply with ROH$ requirentento / Includes, retaining nut 3/8' 8293957 SWXP 35 1798 (16 ga) 80 (Lurninaire) -Pres~ 35 416 .CQndi/I & S A Mu/i V X- P R E S S Installs into Metal Deck, Purlin, or Tubular Steel The Sammy XPress expands to provide direct vertical attachment in: light gauge steel deck or purtin (22 go. 1/8"), Installs in seconds with Sammy X-Press It Tool, saving time & installation costs. Use in applications where access to the back of the Installed fastener is prohibited, ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility, Made in the U.S.A Wwwuh a video de,nanttration a! w.1twbutIdexcom 1/4' 8181922 XP 200 Sammy tl48)2Zga) 195 (Luminaire) 2' .125' 25 125 Metal Deck X-Press 200 250 (Luminaire) .056" 850 (2W Pipe) .027" 940 (2" Pipe) 029' 3/0" 8150922 XP 20 Sammy 1146 (22 ga) 185 (Luminalre) .027" 1475 (4' Pipe) .104' .125' 25 125 Metal Deck X-Press 20 250 (Luminaire) .056" 283 (Conduit 0 Cable( .029' 1500(4' Pipe) .060" 4 '€' 3/8' 8153922 XP 35 Sammy1783 (16 185 (Luminaire) .125" 25 125 Purl/i X-Press 35 250 (Luminaire) '056, 1475 (,V'Pipe) 104' 41& (Conduit &Cable) .059' r I Pre-Pour Structural Concrete@ 3000 psi MASI Dec ..4 j 8150922 XP 20 1146(22ga) 850(2'/aPipe) 25 125 (Pro-pour) L L _____________ X-Press 20 Post-Pour Range II LWC~ 35 PCF (lbs/ft) Metal PrePour Structural Concretag 3000 pal Poat.Pour Range It LWCS 35 PCF (Ibs! ft') 'JLJ 'H The SidewtnderX.Press expands to provide • Less jobsite material needed. horizontal attachment in: -16 ga - 3/16' steel- purlin, tubular steel. No retaining nut required. f(SWXqP) 'Installs In, seconds with Sammy X-Press Ita Tool, 'Provides design flexibility. saving time & installation costs. 'Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; ie, metal roof deck, tubular steel, or vapor barrier fabric. Watct a ridao demanafralian at wwwitwbu(tdex,cam ZTLIZENl yff I The Sw1veIXPess allows you to hang plumb in extreme roof pitches: 89' In z-pudin 4 ° in metal deck for 12/12 pitch Installs in seconds with $anrrny X-Press It' Tool, saving time & Installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required, Provides design flexibility. Made in the U.S.A. Weth a vida'demonsfredqn a www.ltwbuitdex,com 750(2' Pipe) 4. > Swivel 3/9' 6294922 SXP 20 170 Vertical ILuminairel 1061 (22 a Vert) 80 45' (Luminaire) .029' 635 IT Pipe) 022' X-Press 20 829(4S Off Veil) 283 Vertical (Conduit & Cable) 233 @ 46' (Conduit & Cable) - 1260 (31/2' Pipe) Swivel 4 €' 3/8" 8295922 SXP 250 Vertical (Luminaire) 1675 (16 ga Vert) 80 90' nal 029° X-Press 35 .059' 635 (2" Pipe) 1568 (89' Off Vert) 500 Vertical (Conduit & Cable) 33@ 82' Conduit 8 Cable) I Swivel 1061 (22ga Vert) 1/2' 8272957 SXP 2.0 X-Press2 829 )45' Off Veil) 125° 25 125 Metal Deck 126' 25 125 Purlin 25 125 Metal )a Swivel 1675 (16 ga Vert) 1/2" 8271957 SXP 3,5 X-Press 3.5 1558(89" Off Vert) .060' .126' 25 125 Put/n The Sammy X-Press expands to provide direct vertical attachment in: metal deck (22-16 gauge) - z-purliri (18-16 gauge) Made in the USA Watch a video den, onstravov ai\ wwwItwbu1W co eLmJ 8194910 Universal X-Press It Tool 8152910 25/64' 0th Bit ]°ool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25194° DIII Bit. APPROVALS Part Number Model Rod Size ~ount Direction UL Max Pipe Size UL Test Load (lbs) UL Min Wood Thickness FM Max Pipe Size Thickness FM Test Load (lbs) FM Min Woo, 8007957 GST 10 3/5" Vertical CPVC 1-1/2' 300 1.1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 308 1.1/2" 8008957 G$T20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 081 20-SS 3/8" Vertical 2.1/2" 850 1.1/2" 8010957 0T 38 3/8" - Vertical 4" 1500 1-1/2" 4" 1475 14/2" 8009925 08125-380 3/8" Vertical 4" 1500 8022925 SWG 25-380 3/8" Horizontal 3.1/2". 4" 1500 1-1/2" 8021957 $WG 20 3/8" Horizontal 2-1/2" - 3`1 1050 1-1/2" 8073925 SWG 20-S$ 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GSI/C8120 3/8" 45 Angle off Vertical 211/2" 850 1-1/2" 8269957 H-GS1/CS120 3/8" 45" Mole off Vertical 4" 1500 1-1/2" 8139957 $H-GSI2O 3/8" 17" Angle off Vertical 1Q50 1.1/2" 4" 1475 1.1/2' Ag ICE= - 8038057 OUR 1 315" Verticai 1500 035" 4 1475 .105" 8037957 OSTR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 OSIR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .10 8845957 081516 3/8" Vertical 4" 1500 .198" 4" 1475 .188" 8046957 TEK5O 3/9" Vertical 4" 1500 .250" 4" 1475 .188' 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .068" 8056857 SWDR 516 3/8' Horizontal 4" 150Q .037" 4" 1475 060" 8054957 SWOR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 $11 DSTR 1 3/8 17 Angle off Vertical 4 1500 035 4 1475 105 8268957 SH-IEK 50 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4" 1500 •. 8150922 XP 20 3/8" Vertical 2.1/2" 850 .027" 2" 940 .0igr ,, 1475 IQF 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029 ,, 4 1475 .125" 8294922 SXP 20 Wr Vertical or up to 45 2 750 027" 2" 635 029 8295922 SXP 35 3/8" Vertical or up to 89* 3-1/2" - - 1250 .060" 2" - 635 .029" 8293957 - SWXP35 3/8" Hoduontat 3.1/2." 1250 060" 8059957 csi 20 3/8" Vertical 4" 8061957 SWC 20 3/8" Horizontal . - 8150922 XP 20 3/8 Vertical 21/2 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranqe II LWC35 PCF 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .02T' 250 .035" 8181922 XP 200 1/4" Vertical 185 027" 250 .035" - 8294922 SXP 20 3/8" - - Vertical .170 8295922 SXP 35 318 vertical 250 060 8280957 SWXP 35 3/8" Horizontal 80 .060" Pan Model Rod Number Mount UL Load UL Min, Steel Listed Application SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/81, Vertical 283 027" Max trade size EMI RMC and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical - 500 .060" Max 4 trade size EMT &6trade szeRMC, IMC, and rigid PVC conduit - 8294922 SXP 20 3/8 Vertical 283 027 Max 4 trade size EMI RMC and IMC & S trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" - Max trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit - 8293957 SWXP 35 3/8 Horizontal 500 060 Max trade size EMT & S trade aze RMC MC and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod - - UI. Usted4S16 - Cable Hanger, Cat N. C-Z2000 Plenum Rated, Complies Sheet Steel Gauges w/ NEC Standards GES€NO. 22ga 20 P. 1Ba 169a. 149L 128. 1/8'YIVI 1I4 Nominal Decimal Equivalent .030" .035" .046" .060" .075" .105" .125" .188" .250" SW25-380 Maximum pipe size in composite wood Joist allowed by UI. isa-4127 UL compliance with NEC Standards 25-380 Maximum pipe awe in wood timber or joist allowed by UL 1* 4 SW20 Maximum pipe size in composite woo mat allowed by tiLe 2-1/2 UI. and FM teats were performed in compliance, with NFPA 13 Standards Featuring requirement 5 tries weight of water-filed schedule 40 pipe plus 250 pounds. 1475 3000 SPECIAL NOTES Engineering Note In 1996, the anchors listed by LJL were tested in plate steel that measured .188" and .118". Subsequent testing was done fr z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press was completed using (.030") or 22 gauge steel metal deck. SammysO Nut Drivers Special nut drivers were designed to be used with Sammys When the appropriate nut drivers are used for installation the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 5001500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammy* for Seismic Please visit www.itwbuitdex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments special care should be taken not just for building attachments but also for the hangers or assemblies being supported Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 182" 1/8" GST 25-380 .280" 7132" SWG2O .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAINEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local' (ANJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com PPENANdER .LsoLnoasco'cu,Moca"ws 4L2OLITEOA*ANCHORFQLU%NAfl 0R21 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products EN Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads ,running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/AoDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor IndeDendent code evaluation IBC®/ IRC® 2015 IBC®/ IRC®2012 IBC®/ IRC®2009 IBC®/ IRC®2006 Hilti, Inc. (US) 1.800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Nominal anchor Setting diameter 1/4 information Symbol Units Nominal bit diameter dbt in. 1/4 Nominal embedment h 0,0 in. 1-5/8 2-1/2 Effective embedment h0f in. 1.18 1.92 Minimum hole depth In. in. 2 2-7/8 ft-lb 18 Installation torque T. (Nm) (24) Wrench size in. 7/16 1 T0 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size - .. da ( .,.• / -. fanch y ') he h nom - 00, h0 Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 7-3,4,5 Nominal Nominal Tension - cN0 Shear - 4V anchor embed. f', = 2,500 psi I = 3,000 psi f = 4,000 psi f' = 6,000 psi f'c = 2,500 psi f' = 3,000 psi f', = 4,000 psi f',, = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 14 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2'3'4'5 Nominal Nominal Tension - 4N0 Shear - anchor embed. f = 2,500 psi f', = 3,000 psi f', = 4,000 psi f', = 6,000 psi I',, = 2,500 psi f'c = 3,000 psi f' 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1/4 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A,, = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - ;,,,,,,, = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors' .2 Nominal anchor Nominal internal Tensile' Shear' Seismic shears diameter thread diameter cN,,,, in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension ON. = 4,A,,,,f,,, as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4W,,,, <0.64,A,,,, f,,,,, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with 4W,,, :5 (P 0.60 A se, ,, f,,,, as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1.800.363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .1. toward edge from edge factor in shear' uncracked concrete IAN 1RN 'AV f" 'Rv 'IW Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a j 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 8 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 0.98 5-1/2 (140) 0.83 0.72 0.93 _6 (152) 1.00 0.86 0.74 _______ _______ _______ _______ 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CZ 10 (254) 0.89 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete12 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear' cracked concrete IAN 'RN lAy fRy 1RV 1HV Embedment in. 1.5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a , 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 1 0.74 0.98 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 a 10 (254) 0.90 11 (279) 0.94 12 (305) 0.98 _______ - 14 (356) 1.00 T 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fA, assumes an influence of a nearby edge. If no edge exists, then I AV = 4 Concrete thickness reduction factor in shear, f,,.,, assumes an influence of a nearby edge. If no edge exists, then f,,,, = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800.363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2A,4,5,6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - qN Shear - cV Tension - 4N Shear -cV anchor thread embed. '= 3,000 Psi 4,000 psi '= 3,000 psif= 4,000 psi ', 3,000 Ps = 4,000 Ps f= 3,000 Psi ' 4,000 Psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"2'3'4'5'67'8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - 4N Shear - _pV Tension -(pN Shear - _pV anchor thread embed. f'= 3,000 psif= 4,000 psif,= 3,000 psif'= 4,000 psi 3,000 psif'= 4,000 psif= 3,000 psif'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 1 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 I Hilti (Canada) Corp. 1-800.363-4458 1 www.hdti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2- Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm, 3/4' C )..#'-'J h1weight rete (fC-,- 3-.),) ,)_ O_j .I çJ SJ - Q2f"4 ?LY'.t Minimum 20 gauge steel deck (typ(cal) Mm. 1-1/4 - 1 Anchors maybe placed In the upper or lower flute of the sleet deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be Installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. II 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex 0, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I N carbon steel screw anchor',' Nominal Internal anchor thread Tensile' Shear' Shear4 diameter diameter N V r V in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements, 3 Tensile N r = A N 4 f,, R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v, < A 4 q, 0.6 f R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with vr < A 4 0.6 ç R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. da in. 1/4 (mm) (6.4) Effective embedment h0 in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h in. 1-5/8 2-1/2 nom (mm) (41) (64) Minimum concrete thickness 4-1/8 in. 3-1/4 (mm) (83) (105) Critical edge distance in. 2.00 2.78 C,(mm) (51) (71) Minimum spacing at critical edge distance Srflfl in. 1.5 (mm) (38) Minimum edge distance in. 1.50 Cftn (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 (mm) I (51) (73) Minimum specified ultimate strength f.. psi 125,000 (N/mm2) (862) Effective tensile stress area A SON in2 0.045 (mm2) (29.0) Steel embed, material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension N lb 3, 370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear Vsar lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V q (kN) (1.5) Factored steel resistance in shear V sar lb 725 D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V r (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k0 ,cr - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete kc,cr - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 Lyc.N - 1.0 D.6.2.6 Anchor category - - 3 1 1 D.5.3 (c) Concrete material resistance factor qc - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete6 Npruncr lb 665 1 1,645 D.6.3.2 (kN) (3.0) (73) Factored pullout resistance in 20 MPa cracked concrete6 IN p,r lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 N5,,eq lb 275 815 D.6.3.2 (kN) (1.2) (3.6) 1 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. 2 See figure 1 of this section. 3 The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex D section D.2. 4 For all design cases, 45 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k0) or uncracked concrete must be used. 5 For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. 6 For all design cases, qi, = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in uncracked concrete' 2,3,4,5 Nominal __________ Tension - N Shear - V f', = 20 MPa f' = 25 MPa I = 30 MPa I , = 40 MPa f' = 20 MPa f . = 25 MPa f = 30 MPa I = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in cracked concrete' 2,3,1,5 Nominal Tension - N __________ ___________ Shear - V I',, = 20 MPa f'c = 25 MPa I' = 30 MPa f'c = 40 MPa I' = 20 MPa f' = 25 MPa I = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNses = 0.75 See section 3.1.8.7 for additional information on seismic applications. Huh, Inc. (U5)i -800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 1,3,11,5,6,7 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Nr Shear - Vr Tension - N Shear - Vr anchor thread embed. f' = 20 MPa f' = 30 MPa f' = 20 MPa = 30 MPa f = 20 MPa f'c = 30 MPa f'c = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 / UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1'2'3''5'6'7'8 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N, Shear - V, Tension - Nr Shear - Vr anchor thread embed. I = 20 MPa I = 30 MPa I = 20 MPa I = 30 MPa I = 20 MPa f = 30 MPa I = 20 MPa I = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 / UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,9e1e 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - a,, = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 kWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress desian values for installations into hollow core eonernt nanAls12 Hanger rod size Min. effective embedment hef in. Allowable load3 Ultimate load Tension lb Shear lb 4.5 Tension lb Shear lb 4,5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 Installation of HlItI KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 33.7,4 installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty / box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 13/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800.363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F. Load Lbs.t WtJ100 3/8 16 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 11.30 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.t WtJ100 3/8 1A6. 1¼ 1 7/16 1 610 28 1/2 11h 1¼ 1 9/16 11/4 1130 55 5/8 11/2 1¼ 1 9/16 114 1130 55 * Max. loads for clamp with sot screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2' and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66. Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig.. 65 Patent #4,570,885 Component of State of California OSHPD Approved c Vi. us usno Seismic Restraints System D OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 'FAX: 951.737.0330 CUSTOMER SERVICE • 800.788, 5269 wwwWko.co,n Fig. 25 - Surge Restrainer C@1111I LISTED Size Range - One size fits 3/4" thru 2" pipe Material Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer Is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2,14,4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2. 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2", Patent #5,344,108 COOPER B-UNE 1375 Sampson Ave • Corona, CA 92879 9 800.786.5266 • FAX; 951.737.0330 Size Range - Secures 318" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Etectro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog apprpved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750° F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish OFFICE/MANUFACTURING FACILITY ' 1315 SAMPSON AVE. . CORONA, CA 92879 PH: 951.1375599 'FAX: 9517370330 CUSTOMER SERVICE 800.7tV.5266 www.tolco.com Fig. 200.21/2 to 200-8 Fig. 200 Fig. 200$ Flu. 200 - "Trimline" Adlustable Band Hanoer (Cooper B-Line Fla. B3170NA TQLQ Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B3170NFF Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Une Fig, B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pro-Galvanized to 090 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2 ' (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger Is easily !'j \, installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig, 200.1 to 2002 Factory Mutual Engineering Approved (FM) 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSl/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) - O Finish: Pro-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By-, Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F ;fliI1ft 200_1/2 Pipe lM. 1/2" Size (15) Rod Size /8"•16 A in. 0D ' 31/a" (79.4) ' 2/8' B Approx. Vit./l 00 - ' ii (5.0) 200-I4 3/4" (20) /81-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 it, (25) 1'-16 3/8' (85.7) 2I8' (66.7) 12 (5.5) 200-1 1I4 11/4" (32) i8"-16 33/4" (94.0) 2/8" (73.0) 13 (5,9) 200-1I2 11/2" (40) i8"-16 37/8" (98.4) 2/" (73.0) 14 (6,4) 200-2 2" (50) 1"-16 41/2" (114,3) 3" (76.3) 15 (6.9) 200_2112 21/2" (85) I8'-16 5/" (142,9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /a"-16 571" (149.1) 4" (101.6) 29 (13.3) 200_3112 31/2" (90) 3/8"-16 7/" (187.3) 51/4' (133.3) 34 1 (15,6) 200-4 4" (100) ia"-i6 718" (187,3) 5" (127.0) 35 (16.0) 200-5 (125) 11/2'..13 91/8" (231.8) 61/4' (158,7) 66 (30.2) 200-6 (150) i/2',.13 10118" (2572) 614" (171.4) 73 (33.4) 200-8 1 8" (200) i/2"_13 131/B' (333.4) 8/4' (222.2) 136 (62.3) PP_ 00 COOPER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig, 200 1/2" (16mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2 (15mm) thru 2' (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) Fig, 21)0-1 to 200-2 in the USA UL and Canada (cUL.) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS $P-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel /71 materials will be supplied with (2) hex nuts in place of a knurl nut. 1 Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. Fig. 200-1/2.200-3/4 Fig. 200-2/2 to 200-8 200M8-1/2 ' ½" (15) M8 ' 31/8" (79.4) ' 2/8" (66.7) 11 (5.0) 200M10-1/2 ½" (15) MID 31/8" (79,4) 25/8' (66.7) Ii (5.0) 200M8-3/4 3/4' (20) MB 31/8 ' (79,4) 21/2' (63.5) 11 (5.0) 200M10-3/4 3/4" (20) MID 3118' (79.4) 21/2" (63.5) 11 (5,0) 200M8-1 1" (25) MB 3I8" (85.7) 2/8' (66.7) 12 (5.5) 200M1-1 1° (25) MID 33f8" (85.7) 2/8' (66.7) 12 (5.5) 200M8-11/4 11/4' (32) MB 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) MID 33f4" (94.0) 21" (73.0) 13 (5,9) 200M8-11/2 11/2 ' (40) Ma 3 /8" (98.4) 2/' (73.0) 14 (6.4) 200M10-11/2 112" (40) MID 3/8" (98.4) 2/s" (73.0) 14 (6.4) 200M8-2 (50) MB 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 2" (50) MID 41/2" (1143) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) MID 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) MID 57f" (149,1) 4' (101.6) 29 (13.3) 200M-3112 31/2" (90) MID 7 /8' (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) MID 73/' (187.3) 5" (127,0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158,7) 66 (30.2) 200M-6 6" 050) M12 101/8" (2572) 34 (171,4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8/4' (222.2) 136 (62.3) All dimensions in charts and On drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PIP- 00 COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range; 2° (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pro-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with 3/"16 or 1/213 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 050OF (343°C) Finish: Pro-Galvanized Order By: Figure number, pipe size and rod size, Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 1Il1II_ 200Il-2-/8 Pipe ' 2" Size (50) Rod Size ' fa'-16 ' A in. FJ._ 4/16' ' (115.9) ' 3/32" B (81.7) sIilE.Y1p i 48 (21.8) 200H-2-1/2 2" (50 1/2°13 423/32° (119.8) 3/a" (85.7) 45 (20.4) 20011-2112-318 21/2" (65) /a'-16 5/16" (134.9) 323/32 (94.4) 59 (26.7) 200K _21/2_1/2 21/2' (65); 112"_13 515/32° (138,9) 3/8" (98,3) 56 (25.4) 200H-3-3/8 3" (75) 3/8"-16 53/4' (146.0) 327/32" (97.6) 63 1 (28.6) 200H-3-1/2 3" (75) 1/2°_13 5/8" (148.1) 331/32" (100.8) 60 (7.2) 200H-4-3/e 4" (100) /a"-16 67/8" (174,6) 4/16" (112.7) 76 (34.5 200H-4-1/2 4" (100) 112°13 71/32" (178.6) 419/32" (1116,7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13, For 6° (150rnr) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and or drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp— go COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°E LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G *FBCI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. © 2012 Fire Protection Products, Inc. FPPI®, LubeRt® are registered trademarks of Fire Protection Products, Inc.Nu FGG/BM/CZ', Blaze-Master, FlowGuard Goloe and Corzan® are registered trademarks of Noveon IP Holdings Corp. MDR IN U.S.A. Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications, 3198 LIONSHEAD AVE THREAD CUTTING OILS OR CARLSBAD, CA 92010 TEL + 1760 599-1168 CONTAMINANTS. + 1 800 344-1822 FAX + 1800 344-3775 Nu © 2013 Fire Protection Products, Inc. FPP/', ThreadFit are registered trademarks of Fire Protection Products, Inc. kA MADE 1$ V4.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBC/A S'STEM COMPATiBLE *FBCTI System Spears® Compatible Compatible indicates indicates that this product has been ThreadFit® CLEAR tested by Lubrizol has been tested Advanced Materials by Spears® and is monitored on Manufacturing to an on going basis be compatible with to assure chemical Flameguard® pipe and compatibility with fittings. FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER Specifications Appearance: Clear amber liquid. Packaging: I gi. (6/case) 5g1, Pail 55-gi drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water, Eye contact: flush eyes with water for at least 15 minutes and seek medical attention, Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC. a 24-hour emergency hotline. They may be reached at 1 800 424-9300. Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPI5, LubeFit are registered trademarks of Fire Protection Products, Inc. F8C', BIazeMaste,, FlowGuard Gold5 and Co,zan5 are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A.