Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5781 VAN ALLEN WAY; ; FPC2017-0213; Permit
Print Date: 01/31/2025 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Permit Type: FIRE-Construction Commercial Work Class: Parcel 4: 2121304400 Track #: Valuation: $1,047,079.63 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPC2017-0213 Status: Closed - Finaled Fire Sprinklers Applied: 08/02/2017 Issued: 08/14/2017 Finaled Close Out: 01/31/2025 4L City of Carlsbad Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Wong, Cindy Plan Check #: Project Title: Description: THERMO FISHER SCIENTIFIC -SPRINKLER TI >100 HEADS (116) Applicant: FPContractor: MILLENNIUM FIRE PROTECTION CORP DCA CAPITAL PARTNERS JOAQUIN CONTRERAS 2218 FARADAY AVE, # STE 120 2950 SAN LUIS REV RD CARLSBAD, CA 92008-7234 OCEANSIDE, CA 92058-1241 (760) 722-2722 (760) 722-2722 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $634.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $821.00 Total Payments To Date: $634.00 Balance Due: $187.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov 'NiMAJILe" MILLENNIUM FIRE PROTECTION CORP. Th ermo Fisher ScientVic TI 17-028 Overhead Fire Sprinkler Material Submittal 7/28/2017 FILE Copy FPC20I7-0213 5781 VAN ALLEN WAY I V, FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. L- IL Ii II - II w• 1 1.315 1.097 1.41 lbs/ft 2 2.375 2.64 lbs/ft 37 3 3.500 4.500 Schedule 40 Pipe 3.260 4.260 4.34 lbs/ft 5.62 lbs/ft 19 1 11 amn IF MvAl II I 1 1.315 1 1/4 1.660 11/2 1.900 1.049 1.380 1.610 1.68 lbs/ft 2.27 lbs/ft 2.72 lbs/ft 70 -- 51 44 I Cr3 1 OCT 3 03 lL IL 30 3.300 1 :1 Ec_0: 3.33 0 1 000 t.vv lVWFL ZI 0Olft 10 PIPE PREPARATION For proper opertion, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturers instructions for the specific fitting used. 1819 Clarkson Road For additional information, c®US Chesterfield, MO 63017 contact your salesperson (800) 325-4467 BULL MDOSE TUBE C today at (800) 325-4467 or LISTED FAX: (636) 537-2645 (636) 537-2600 in the USA, www.bullmoosetube.com or from Canada _______ AC company e-mail: sa1es.bu11moosetube.com call (800) 882666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 7/09 I Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description [vds} (üj See Fire Protection V.A Submittal Sheet for Pressure Rating and Listing/Approval Information The Figure 40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wellas with theapplicablestandards of the National Fire Protection Association, in addition to the standards of any otherauthorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their lire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershould be contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing / Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade F" EPDM green color code. (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "F" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of theirfire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractororproduct manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards of any otherAuthorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumefor it, anyotherobligation in connection with the sale of products or parts of products. Tyco Fire Products shallnot be responsibleforsprinklersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALLTYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY a'MWE IN LIEU OF ANY AND ALL OTHER WARRAWIlES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTIcULAR PURPOSE. Page 1 of 2 September 2004 TFP172O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/40 x 1/2" 2.00 1.50 3.50 1.20 1/16 0.84 50.8 38.1 88.9 30.5 1 30.2 0.4 11/4"X3/4" 2.00 1.50 3.50 1.20 1/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4 1' 2.31 1.68 3.50 1.20 13A6 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X 1/20 2.12 1.62 3.50 1.32 1/16 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2 X3/4" 2.12 1.62 3.50 1.32 1/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/2 2.43 1.80 3.50 1.32 13A6 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2" x 1/20 2.36 1.86 3.74 1.55 1/16 0.88 59.9 47.2 95.0 39.4 30.2 1 0.4 2" x 3/" 2.36 1.86 3.74 1.55 13A6 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" x 1' 2.67 2.04 3.74 1.55 1/16 1.16 67.8 51.8 95.0 39.4 30.2 0.5 2/2' X 1/2" 2.61 2.11 4.25 1.80 13A6 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2 X3/4° 2.61 2.11 4.25 1.80 1/is 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2 i 2.92 2.29 4.25 1.80 13A6 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 11/4" X 1" 8 V/20 x 1" 6' 2"x 1" 6 21/2" x 1" 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2of2 TFP1720 Figure 40.5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (1141000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Technical Description 0Data ® <S> See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI B16.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: /2" - 21/2" Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. r3Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. 11 Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable, standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 -2- Size Inches A inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/8 /16 86206 0.24 240 3/4 1/i6 3/4 86205 0.40 120 1 11/2 13/16 86200 0.64 70 11/4 1/4 11/16 86201 0.95 1 40 11/2 115/16 13/ 16 86202 1.24 30 2 21/4 11/2 86203 1.74 20 21/2 211/16 1/16 86204 3.28 10 Figure 815 Reducing Tee P I-F - L1 Size Inches A Inches B Inches C Inches 0 Inches E Inches F Inches Part Number Wt Lbs. Box Qty. 3/4 X3/4X 1/2 1/16 1/16 11/4 /8 /8 11/16 86235 0.46 95 3/4X3/4 X 1 1/16 1/16 1/8 /8 /8 11/16 86755 0.68 65 1 x1/2 x 1 11/2 13/8 11/2 13/16 13/16 13/16 86236 0.70 55 1 x3/4X 1/2 11/4 1/16 1/8 /16 /8 13/16 86756 0.63 80 1 x 3Ix 3/ 1I8 1/16 1I16 11/16 3/4 /8 86757 0.68 65 1 X3/4X 1 11/2 1/16 11/2 13/16 /e 13/16 86237 0.77 55 lxi XV2 11/4 11/4 1/8 /16 /16 13/16 86238 0.66 65 lxi X3/4 1/8 1/8 i/16 11/16 11/16 7/8 86239 0.73 60 1 X x 11/4 111/16 111/16 19/16 1 1 Is 86240 0.97 45 lxix 1112 113/16 113/16 1/a 11/8 11/8 1 7/8 86241 1.141 35 11/4 X X 1/2 115/16 11/4 1/16 /8 /16 1 86242 0.81 50 11/4 X 1 x3/4 li/is la/a 1/8 3/4 11/16 11/16 86243 0.90 50 11/4 X X 1 /6 11/2 111/16 /8 13/16 1 86244 1.03 45 11/4X lx 11/4 i'4 111/16 1/4 11/16 1 11/16 86245 1.10 40 11/4x1 X11/2 17/8 113/16 113/16 1/16 11/8 11/16 86246 1.43 30 11/4x11/4x1/2 13/8 1/8 1s/16 11/16 11/16 1 86247 0.87 45 11/4X11/4X3/4 17/ 16 1/16 1/8 3/4 3/4 11/16 86248 0.96 45 11/4 xl 1/4 X 19/16 19/1, 111/16 /8 /8 1 86249 1.10 40 11/4x11/4x11/2 i/8 1/8 113/16 113/16 113/16 11/16 86250 1.50 30 11/4x 11/4x2 21/8 21/a 2 1/16 i/16 11/8 86251 2.00 24 11/2 X x 1/2 1/16 l/16 111/16 11/16 /8 11/8 86252 0.97 40 11/2 x 1 X3/4 11/2 13/8 1/4 3/4 11/16 1 l/16 86253 1.14 40 11/2 X lxi 1/8 11/2 113/16 /8 13/16 11/8 86254 1.14 30 1V2X1 x 11/2 115/16 113/16 115/16 13/ 16 11/8 l/16 86255 1.52 30 11/2X11/4X1/2 1/16 i/16 111/16 11/16 /8 11/8 86257 1.03 40 11/2X11/4X3/4 11/2 1/16 1/4 3/4 3/4 13/ 16 86258 1.10 40 11/2X11/4X1 la/a l/16 113/16 7/ 7/ 11/8 86259 1.31 30 11/2X11/4 X2 2/16 21/a 2 1/16 1/16 1 11/4 186260 1.94120 11/2x11/2x1/2 1/16 1/16 111/16 11/16 11/16 11/8 86261 1.14 35 11/2x11/2x3/4 11/2 11/2 1/4 3/4 3/4 1/16 86262 1.23 35 11/2 x11/2x1 la/a la/a 113/16 /a /a il/a 86263 1.38 30 11/2X 11/2x 11/4 113/16 113/16 17/8 11/16 11/16 13/1 6 86264 1.50 30 11/2 x11/2x2 2/is 2/is 2 1 i/is 1 /l6 11/4 86265 2.00 20 2x 1 x2 21/4 2 21/4 11/2 1/16 11/2 86266 2.18 15 2x 11/4x2 21/4 21/8 21/4 11/2 1/16 11/2 86267 2.31 15 2 xi 1/2 X 1/2 11/2 17/ 16 11/8 3/4 11/16 15/16 86268 1.50 30 2X11/2 X3/4 1/8 11/2 115/16 /8 3/4 13/8 86269 1.61 25 2X11/2X1 l/4 1/a 2 1 /a l/16 86270 1.65 20 2x 11/2x 11/2 21/16 115/16 2/16 1 /16 13/ 16 1 /16 86272 2.03 20 2x11/2x2 21/4 2/i 21/4 11/2 1/16 1 11/2 186273 2.37 15 2x2x1/2 11/2 11/2 17/8 3/4 3/4 l/16 86222 1.50 30 2x2x3/4 la/s la/a 115/16 /a /a la/a 86223 1.67 20 2x2x 1 l/4 1/4 2 1 1 l/16 86224 1.91 20 2 x 2 x 11/4 17/8 17/8 21/8 11/8 11/8 17/16 86225 2.05 20 2 x 2 x 11/2 2 2 2/16 11/4 11/4 11/2 86226 2.11 15 2 x 2 x 21/2 2/8 2/8 2/a 1/4 17/8 1 /16 86227 3.67 10 21/2 X2X3/4 1/4 la/a 2/16 /a /a 1 l/4 186274 12.22 15 TBT Figure 812 901 Reducing Elbow Size Inches A Inches B inches C inches D inches Part Number Weight Lbs. Box Oty. 3/4 x 1/2 1/16 1/16 5/ '/8 86342 0.33 160 1 x 1/2 11/4 1/8 /16 13/16 86210 0.44 110 1 x 3/4 1/8 1I16 11/16 /8 86211 0.53 90 11/4 x 1/2 1/16 11/2 /8 15/16 86212 0.64 75 11/4 x 3/4 1/16 1/8 3/4 11/16 86213 0.75 60 11/4 X 1/16 111/16 7/8'1 86214 0.77 55 11/2 X 3/4 11/2 1/4 3/4 1/16 86221 0.95 45 11/2 X 1 1 /8 113/16 /8 11/8 86215 0.99 40 11/2X 11/4 113/16 1/8 11/8 1/16 86216 1.14 35 2 x 3/4 1 115/16 7/8 V/8 86217 1.39 30 2 x 1/4 21/16 2 1/16 86218 1.58 25 2 x 11/2 2 2/16 11/4 1/16 86220 1.67 20 21/2 x 2 2/8 2/8 11/4 1/8 86262 3.01 15 Figure 811 900 Elbow Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 /8 /8 86780 0.22 250 3/4 1 /16 86781 0.33 150 1 11/8 13/16 86280 0.48 90 11/4 1/16 /8 86281 0.73 50 11/2 1/16 11/16 86282 0.93 35 2 111/16 15/16 86283 1.55 18 21/2 115/16 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/8 s/16 86340 0.33 150 3/4 15/ 16 3/4 86341 0.50 90 1 11/2 13/16 86230 0.85 60 11/4 1 i/4 1 11/16 86231 1 1.30 35 11/2 115/16 13/16 86232 1.63 24 2 21/4 11/2 86233 2.63 12 21/2 211/16 1/16 86234 4.55 8 Figure 813 45° Elbow Figure 814 Tee Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 3/4 x 1/2 1/4 11/16 86772 0.38 240 1 X 1/2 1/16 1/2 86228 0.38 200 1 x 3/4 1I4 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 x 11/2 11/2 72751 0.20 300 1/2 X2 2 72980 0.27 250 3/4 x 11/2 11/2 72981 0.22 250 3/4 x 2 2 72982 17.31 200 Figure 816 Reducing Coupling Figure 719 Cast Iron Plug Figure 817 - - -1 Cross c Figure 827 Hex Bushing Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Oty. 1 11/2 11/2 13/16 13/16 86284 0.97 45 11/4 1/4 1/4 11/16 11/16 86285 1.59 25 11/2 1'/,6 115/16 1/16 1/16 86286 1.89 20 2 21/4 21/4 11/2 11/2 1 86287 2.93 10 11/4 x 11/4 x 1 x 1 111/16 19/16 1 /8 86289 1.25 30 11/2 X 1'/2X 1 xi 11 /,6 1/ 11/16 115/16 86322 1.48 24 2 x 2 x lxi 2 1/4 11/4 11/16 86291 2.64 10 A Part Weight Box Inches Inches Number Lbs. Oty. 1 x 1/2 11/16 72726 0.22 280 1 x 3/4 11/16 72762 0.18 270- 11/4 x 1 1/16 72763 0.31 150 11/2 x 1 11/4 1 72757 0.53 1100 11/2X11/4 11/4 72764 0.35 100 2 x 1. i/8 72759 0.75 80 2x 11/4 1/8 72761 0.69 80 2x 11/2 1/8 72775 0.62 80 Figure 818 B A Straight Coupling Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Oty. 1/2 13/8 /16 72779 11/8 0.18 360 3/4 i/8 /16 72778 1/ 0.26 200 1 13 A 3/8 72755 111/16 0.44 110 11/4 2 9AB 72754 2 0.54 75 11/2 2/16 3/4 72753 21/4 0.71 60 2 2/8 11/8 72752 2/4 1.15 30 21/2 3 3/4 72758 3/s 2.29 18 ILI1IJ Figure 830 ____________ Brass Seat Union Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 17 13/16 86207 0.47 110 3/4 2 15/16 86275 0.66 80 1 2/16 1 /16 86276 1.08 50 11/4 2'/2 1 11/16 1 86277 1 1.54 35 11/2 2/8 1/16 86278 2.03 25 2 31/8 1/ 86279 3.15 1 18 Figure 820 Cap IHPU Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 7/8 72776 0.15 500 3/4 1 72777 0.22 300 1 i/m 72824 0.33 180 11/4 1/16 72756 0.54 110 11/2 13/8 72822 0.68 80 2 11/2 72823 0.96 45 21/2 l/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 15/16 86292 0.10 500 3/4 11/8 86293 0.18 300 1 11/4 86294 0.28 200 11/4 i/8 86295 0.50 1 110 11/2 i/l6 86296 0.70 1 80 2 11/2 1 86297 0.90 1 45 - -3- Street Elbows A Fr D-11 California Tees Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Qty. 1 X /2 1 V2 3/4 3 42003 0.70 80 1 x 1 1 lIz 3/4 3 42002 0.90 60 Size Inches A Inches B Inches C Inches 0 Inches Part Number Weight lbs. Box Qty. 1 x 1/2 x 1 1 V2 7/ 3 3/4 42000 0.95 50 1 xi x 1 11/2 3/4 3 3/4 42001 0.95 45 CILimited ____Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, atTyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYANDALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designers responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. ti_ICC/Flow Control/ Tyco Fire Products Printed U.S.A.10-01 Bulletin 014 Rev. P [II m ®R) 143bi Model Fl FR Series Quick Response Glass Bulb Sprinklers KAV Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS SchadenverhUtung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex C (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1 425), 0786-C PD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Recessed Concealed Recessed Horizontal Sidewall Pendent PendentJFP XLH Upright XLH Pendent XLH Recessed Pendent F1/172 Product Description Reliable Model Fl FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- PendentFP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height _____ Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 DorW2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 DorW2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 DorW2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 225 57 DorW2 RA1413 cULus 2 Recessed Pendent 225 57 GFR2 RA1413 cULus 2 Upright 225 57 DorW2 RA14231 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 0 or W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 DorW2 RA1413 cULus 2 Recessed Pendent 225 57 GFR2 RA1413 cULus 2 Upright 225 57 DorW2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 DorW2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 225 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 DorW2 RA1425 cULus, FM, LPCB,VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" D or W2 RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 DorW2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 225 57 RC1 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 0 or W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 DorW2 RA1485 cULus, FM, LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the Fl FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbuib brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. 7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. 9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 0 Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus F1FR4O Pendent VdS Recessed Pendent VdS I -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus FIFR42LL Pendent -- I cULus, ULH I I -- I Recessed Pendent -- I cULus, ULH -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC I -- FIFR56 Concealed Pendent* cULus I cULus,VdS,EC cULus -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- I cULus, ULH I -- F1FR56LL Recessed Pendent -- I cULus, ULH I -- _________ Concealed Pendent* -- cULus, ULH I -- Horizontal Sidewall cULus, FM F1FR56 _________ Recessed Horizontal Sidewall cULus, FM I -- FIFR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Deflector! Model ,. Orientation (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS,EC F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/879.5mm] / F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] Fl ESCUTCHEON AT MAXIMUM RECESS = 7/8[22.2mm] I/AT MINIMUM RECESS = 1-5/8"41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8728.6mm] AT MINIMUM RECESS 1-5/8741.3mm] - 2 1/4 HOLE OH. [57.2mm] I 15/16" 014 [49.2mm] " r 1 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS \ IF I -101 L I________ Fl ESCUTCHEONj_ V Z7 3/4 719mm] ADJUSTMENT F2 ESCUTCHEON 1/2112.7mm]11 M ADJUSTMENT 2 27/32' 0/A. [72.2mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR421-L, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 2 5/8" 0/A. [66.7mm] HOLE IN CEILING 2 5/16" 0/A. [58.7mm] CUP CEILING Esk\ Y"[12.7mm] ADJUSTMENT 3 1/4" 0/A. [82.6mm] 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CE/LING DIMENSION AT MAXIMUM RECESS = 1-1/2738mm] AT MINIMUM RECESS = 1 '125.4mm] AT MAXIMUM RECESS = 9/16714.3mm] AT MINIMUM RECESS = 1 "[25.4mm] Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. 2 5/16" 0/A - CUP CEILING —/ 1/2" MAX. I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER -HHI/8" - r!I_[3.2mm] TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. -H FACE OF FITTING TO FACE OF CEILING DIMENSION F! ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[l9mm] AT MINIMUM RECESS = 3/8 "[9.5mm] 2 1/4" HOLE DIA. [5 7.2mm] 1" x 1/2" REDUCER 1 15/16" DIA.)ttL -i [49.2mm] I I Fl ESCUTCHEON AT AlA VIAl! IA) otrrcc - zo"rz4 I ''/ .J't.iIIflIJ AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8 "[41.3mm] AT MINIMUM RECESS = 2- 1/16"[52.4mm] 2 27/32" DIA. [72.2mm] Fl ESCUTCHEON 3/4"[l9mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT I (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR 1'J.. OIJIJ( RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW III:I:IIIIIII} —25/8" 0/A. H HOLE IN CEILING 1 1/2" MAX. i FACE OF FITTING TO FACE OF CEILING DIMENSION 15/16" J 5/16" DIA. CONCEALED, 1/2" ADJUSTMENT 0I7FGO1A Fig. 4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model COP cover plate I" x 1/2" REDUCING TEE OR ELBOW 2 5/8" 0/A. 2 5/16" 0/A HOLE IN CEILING CUP 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING 5/16" MAX. 3/4" COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER i CONCEALED, 5/16" ADJUSTMENT O17f602A Fig. 5 - Model Fl FR56/1`1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model COP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate111 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4X5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover platet Electroless Nickel PTFE17 Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint126 Black Paint Off White Off White (2X6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSw), RA1485(vSw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA 1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR40][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (570C)][155°F (68°C)][1750F (79°C)] [200°F (930C)] [286-F (141 00)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile COP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (570C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. AIQ Recycled R121i a I) I ® (800) 431-1588 Sales Offices Paper (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address [0. Printed in U.S.A. 03/17 P/N 9999970300 Bulletin 157 Rev. M liable Model F3QR56 Dry K5.6 (80 metric) Quick-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon Pendent with Model HB extended escutcheon Pendent with Model FP recessed escutcheon Pendent with Model Fl recessed escutcheon Concealed Pendent with Model COP cover plate Horizontal Sidewall with Standard escutcheon Horizontal Sidewall with Model HB extended es- cutcheon Horizontal Sidewall with Model FP recessed es- cutcheon (FM Standard Response) Horizontal Sidewall with Model Fl recessed es- cutcheon (FM Standard Response) Available with 1" NPT, lS07-1R1, 3/4" NPT, or 1S07- 1 R3/4 inlet fitting. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprin- kler fitting. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). Product Description Model F30R56 Dry sprinklers are quick-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent or Dry Horizontal Sidewall configurations, Model F30R56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. Model F30R56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler systems in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F30R56 Dry sprinklers are available with a vari- ety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F30R56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Avail- able sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model Fl escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F30R56 Dry sprinklers; the use of any other recessed escutcheon or cover plate with Model F30R56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Pendent (See Fig. 1) Pendent / HB (See Fig. 2) Recessed FP Pendent (See Fig. 3) Concealed (See Fig. 4) IL Recessed Fl Pendent (See Fig. 5) Horizontal Sidewall (See Fig. 6) Horizontal Sidewall / HB (See Fig. 7) ' C;~' 94# Recessed FP Horizontal Sidewall (See Fig. 8) Recessed Fl Horizontal Sidewall (See Fig. 9) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Inlet fittings are available with 1" NPT, ISO 7-1 Ri, 3/4" NPT, See the Available Configurations, Listings, and Approvals or 1S07-1 R314 threads. Sprinklers with 3/4" NPT and 1S07- table in this Bulletin for further information on Model F30R56 1R3I4 inlet fittings are intended primarily for replacement of Dry sprinklers. existing 3/4" or lS07-1R3/4 inlet dry sprinklers, but may also be used in new installations. Available Configurations, Listings, and Approvals X: Sprinkler Model Escutcheon or Cover Plate Available Length (See Figs. 1-9) Listings and Approvalst1) Inlet Threads Sprinkler Identification Number (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon 3-1/2" to 36" cULus, NYC 3/4" NPT or 1S07-1R3/4 Fl Recessed Escutcheon (90 to 900 mm) FP Recessed Escutcheon CCP Cover Plate P. F30R56 Dry Pendent Standard 2" to 48" R5714 Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT Fl Recessed Escutcheon 3-1/2" to 48" cULus, FM, NYC or 1507-1R1 (90 to 1200 mm) FP Recessed Escutcheon CCP_ Cover _Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus2, NYC(2) 3/4" NPT Fl Recessed 3-1/2" to 48" or S07-1R3/4 Escutcheon (90 to 1200 mm) FP Recessed F30R56 Dry Escutcheon Horizontal R5734 Sidewall Standard Escutcheon 2" to 48" (50 to 1200 mm) cULust2t, FM 3 , NYC(2) HB Extended 3-1/2" to 48" Escutcheon (90t0 1200 mm) 1"NPT or 507-1A1 Fl Recessed Escutcheon 3-1/2" to 48" cULust2 , FP Recessed (90 to 1200 mm) FM34t, NYC(2) Escutcheon "For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. I (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. " FM Approved for Light Hazard only. (4) Model F30R56 Dry Horizontal Sidewall with Model Fl or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Patents Model F30R56 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) Certified by FM Approvals (FM) Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi112 (80 L/min/bar112) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F30R56 Dry Pendent cULus, NYC -- 250 psi (17.2 bar) FM -- 175 psi (12 bar) F30R56 Dry Horizontal Sidewall cULus, NYC _____________________________ ___________________________ 4" to 6" 250 psi (17.2 bar) 6" to 12" 175 psi (12 bar) FM -- _____________________________ 175 psi (l2bar) Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals(" Ordinary Orange 135°F (57C) 135°F (57°C) 100°F (38°C) 155°F (68°C) cULus, FM, NYC Red Intermediate Yellow 175°F (79°C) 165°F (74°C) 150°F (66°C) cULus, NYC Intermediate Green 200°F (93°C) 165°F (74°C) 150°F (66°C) cULus, FM, NYC High Blue 286°F (141°C) None 225°F (107°C) cULus, FM2 , NYC 165°F (74°C) 150°F (66°C) cULus, NYC For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes Component Sprinkler Escutcheon(1) Cover Plate Standard Finishes Bronze Brass(') white Paint White Polyester(2) White Polyester Chrome Chrome Chrome Special Application Finishes Electroless Nickel PTEE2 Electroless Nickel PIFE Black Polyester Customer Color Polyester Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester(2) Custom Color Polyester Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model Fl escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized steel with no further finish. cULus Listed as a Corrosion Resistant Sprinkler. Brass finish available for standard, Model El, and Model FP escutcheons only. S 3. Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A" Dim 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 2" to 36" (51mm to 914mm in 1/4" (6mm) increments for 3/4" c.nnner.tions ii ___ L FTN System Fitting Inlet Fitting I 2-1/8" [54mm] Dia. "A" Dimension Hole in Ceiling 1-21/32" Dia. [42 mm] Sprinkler Can Escutcheon eiling Nominal Escutcheon Position 1/4" [6 mm] _J Protrusion at Nominal Escutcheon Position 1-1/2" [38 mm] Total Adjustment 1-1/4" [32 mm] Ceilings Escutcheon Adjustment 1/4" [6 mm] Escutcheon L' Ceiling ', Adjustment I 1-5/8" 3" [76 mm] [41 mm] DlA. I 153FG01-G Fig. 1 Note: The sprinkler can protrudes ¼" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +11/4' (+32mm) 'A" dimension adjustment range. Sprinkler Guard: Model C2 4, Model F301156 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) "A" Dim. 3½ to 48" (89mm to 1219mm) in 1/4(6mm) increments for 1 " connections or 1 rtt l iir II System Fitting 2-1/2" [64 mrni Dia. "- Inlet Fitting Hole in Ceiling 'A' Dimension 3-1/2" [89 mm] Escutcheon Dia. 1/2" [12.5mm] f Escutheon Adjustment Ceiling Escutcheon Sprinkler Can 7 1" [25 mm] Total Escutcheon Adjustment 1/2' [12.5mm] Escutheon Adjustment Nominal Position of Escutcheon I 1-1/4" [32 mm] Protrusion at L) J [41 mm] 1-5/8" Nominal Escutcheon Position 157FG02B 2-3/16" [56 mm] Dia. Fig. 2 Note: The sprinkler can protrudes 11/4' when escutcheon is in nominal position. Escutcheon adjustment provides -½" (-12.7mm) to +1/2" (+127mm) "A" dimension adjustment range. Sprinkler Guard: Model 02 5. 1/4" [6 mm] Escutcheon Adjustment 1/4" [6 mm] Escutcheon Adjustment 1/2" [12 Total Escutcheon Adjustment 3-7/32" H- [82 mm] Dia. 153FG02-F Model F301356 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "A" Dim 31/2" to 48" (89mm to 1219mm) in 1/4"(6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm') in 1/4(6mm') increments for 3/4' conner.tions *-J L System Fitting Inlet Fitting 2-1/2" [64 mm] Dia. Hole in Ceiling "A" Dimension 2-9/32"[58 mm] Dia. Nominal Sprinkler Escutcheon Cup Position - - - ) Ceiling - Escutcheon Ceiling Fig. 3 Note: Do not install the Model F30R56 Dry Pendent sprinkler with the Model FR escutcheon in ceilings which have positive pressure in the space above. on 153FG03-F 3/8" 110 mm] Total Cover Plate Adjustment 3/16" [5 mm] Cover Plate Adjustment 3/16" [5 mm] Cover Plate Adjustment Ceiling 3-5/16" [84 mm] Dia. Model F301356 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) to 4811" (89mm to 1219mm) in 1/I'll4"(6mm)increments for 1' connections or \ 211 44i- I System Fitting Inlet Fitting 2-1/2 [64 mm] Dia. Hole in Ceiling "A" Dimension I 2-9/32 [58 mm] Dia. Nominal Sprinkler Cover Plate Cup Assembly Position Model CCP 1/2 Cover Plate Assembly Ceiling i (Adjustment Limited to 3/8" [10 mm]) Fig. 4 Note: Do not install the Model F30R56 Dry Pendent sprinkler with the Model COP cover plate in ceilings which have positive pressure in the space above, 7, 1/4"[6mm] - Escutcheon Adjustment 1/4'[6 mm] Escutcheon Adjustme 1/2" [12 mm] Adjustment I Model F30R56 Dry Pendent Sprinkler with Model Fl Recessed Escutcheon (SIN R5714) "A" Dim 31/2' to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections or 31/2" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections. I liii H I liii I I j L - - j System Fitting 2-1/4'[57 mm] Dia. Hole in Ceiling Inlet Fitting 1-15/16' [49mm] Dia. "A" Dimension Nominal Escutcheon Position Ceiling Ceiling 1/8" [3 mm] 'i- Escutcheon 2-27/32" 157FG05B [72 mm] Dia. Fig. 5 0 1/4°[6mm] Escutcheon Adju 2-3/32° [53 mm] 3° [76 mm] Model F30R56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) "A" Dim 2" to 48" (51mm to 1219mm) in 1/4' (6mm) increments for 1" connections or 2" to 36" (51 mm to 914mm) in 1/4" (6mm) increments for 3/4" connections System Fitting 1-1/2° [38 mm] Total Escutcheon Adjustment 1-1/4° [32 mm] Escutcheon Adjustment Inlet Fitting Ceiling 4'[102 mm] Mm. I 12° [305 mm] Max. 2-1/8° j [54 mm] Dia. Hole in Wall Sprinkler Can A Dimension 1/4° [6 mm] Protrusion at Nominal Escutcheon Position Nominal Escutcheon Position 157FG06B Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/4" (-6mm) to +1'/4" (+32mm) "A" dimension adjustment range. I Model F301356 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) "A" Dim 31/2 to 48" (89mm to 1219mm) in 1/4" (6mm) increments for 1" connections o 31/2" to 36(89mm to 914mm) in 1/4" (6mm1 innrmnts tnr /4" lnnnpr1tinn 1" [25.4mm] Total Adjustment Ceiling 1/2 [12.7mm] - 4' [101 .60mm] Escutcheon Adjustment Mm. 1/2°[12.7mm] 12 [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee [53.18mm] Inlet Fining 2-13/64" 3-1/2' [55.88mm] Dia. Escutcheon Dia. [88.9mm] 2 1/2" Dia. [63.5mm] - Hole in Walt 1-1/4' [31.75mm] Nominal Protrusion Sprinkler Can A' Dimension Escutcheon Nominal Position 157FG07B of Escutcheon Hg. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment provides 1/2" (-12.7mm) to +1/2" (+ 12.7mm) "A" dimension adjustment range. 10. Model F30R56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) FVDIM.31/2 to 48" (89mm to 1219mm) in 1/4"(6mm) increments for 1" connections or 3'/2" to 36(89mm to 914mm) in 1/4"(6mm) increments for 3/4' connections System Fitting iLI 157FG08B Ceiling 1-13/32" Escutcheon [36 mm] 4'[102 mm] Mm. Cup \\ cULN [152 mm] Max. Inlet Fitting 5/8" [16 mm] 3-7/32" [82 mm] Dia. 2-1/2" [64 mm] Dia. Hole in Wall Nominal Escutcheon Position 2-19/64" h 1/4 6 mm [58 mm] Dia. - eon Adjustment "A" Dimension ____________ 1/2' [12 mm] ______________ Total Escutcheon Adjustment - 1/4"[6mm] Escutcheon Adjustment Note: Do not install the Model F30R56 Dry Horizontal Sidewall sprinkler with the Model EP escutcheon in walls which are positively pressurized with respect to the protected space. Model F301356 Dry Horizontal Sidewall Sprinkler with Model Fl Recessed Escutcheon (SIN R5734) "A" Dim 31/2' to 48" (89mm to 1219mm) in 1/4' (6mm) increments for 1" connections o 3½" to 36" (89mm to 914mm) in 1/4" (6mm) increments for 3/4" connections I System Fitting Escutcheon Ceiling [3 mm] 4'[102 mm] Mm. cULus, NYC: 6"[152 mm] Max. FM: 12"[305 mm] Max. Inlet Fitting au'ft 2-1/4" [57 mm] Dia. Hole in Wall 1-15/16" [49 mm] Dia. 157FG09B "A" Dimension - 5/8" [16 mm] 2-27/32" [72 mm] Dia. CO Nominal Position of Escutcheon - 1/4"[6mm] utcheon Adjustment 1/2" [12 mm] Total Escutcheon Adjustment - 1/4" [6 mm] Escutcheon Adjustment Fig. 9 12. (HEATED AREA) INSIDE FACE (HEATED AREA) MINIMUM EXPOSED BARREL LENGTH DECKTITE FLASHING (SEE ABOVE) RASCO#4003910 (RECOMMENDED) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM (DRY PENDENT SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) AMBIENT TEMPERATURE EXPOSED To DISCHARGE END OF SPRINKLER* EXPOSED BARREL AMBIENT TEMPERATURE 40F14C I 50*FI10'C I 60F1160 EXPOSED MINIMUM BARREL LENGTH (FACE OF FITTING TO TOP OF CEILING) IN. (MM) IN. (MM) IN. (MM) 40W (4'C) 0 0 0 30W (-i-d) 0 5 0 20W (-7'C) 4(100) S 0 lOW (-12'C) B (200) 1(25) S 0'F(-IB'C( 12(200) 3(75) S -lOW (-EEC) t4 (350) 4(150) 1(25) -20W (-29'C) 14(350) 6(I50) 3(75) .30W (-34'C) 16(400) B (200) 4(100) -40W (-40C( 18(450) B (200) 4(100) -50W (-46'C) 20(500) 10(250) 6(150) -60W (-NrC) 20(500) 10(200) 6(100) FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE A DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY PN THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEXING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE WALL FOR DRY HORIZONTAL SIDEWALL SPRINKLERS. WET PIPE L..,1 ,—IF HUMIDITY AND TEMPERATURE DIFFERENTIAL / CAUSES CONDENSATION ON THE EXPOSED DRY / SPRINKLER. CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING / TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) EXPOSED SEAL THE CLEARANCE SPACE BARREL / AROUND THE SPRINKLER TO AVOID / LEAKAGE OF AIR INTO THE PROTECTED LENGTH / AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE / PREMATURE OPERATION. SEE BELOW FOR 'A CLEARANCE RECOMMENDED METHODS. DIMENSION HOLE _________________ ESCUTCHEON (PROTECTED AREA) CEILING LDISCHARGE END OF SPRINKLER RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO DRY HORIZONTAL SIDEWALL SPRINKLERS RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) WET PIPE WET PIPE (PROTECTED AREA) DISCHARGE END OF (PROTECTED AREA) DISCHARGE END OF DRY SPRINKLER DRY SPRINKLER IN COLD AREA IN COLD AREA 157FG10C Fig. 10 13. *CAUTION* RELIABLE DRY PENDENT AND DRY HORIZONTAL SIDEWALL SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLERS INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet-pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal F Obstruction Obstruction Female ___ Female Pipe I Pipe I Thread-7 Thread-' CPVC Fitting with Internal Obstruction CPVC itting - No Internal Obstruction Inlet Inlet Male Male ShPipe Pipe orter Lo Thread Thread nger -7 Dry Sprinkler Dry Sprinkler Short Inlet ('PL') Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION O16FGO8C Fig. 11 14. Fig. 12 - Model F3 or Model F3R Wrench ri I_ ri - . . Ary I I Hg. 13 - Model XLO2 Wrench 15. MATERIAL SPECIFICATIONS Fig. 16 16. ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS 036000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS 036000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) ol6fglo 153fg16 157fg16 PPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Installation Instructions Model F30R56 Dry sprinklers must only be installed in the following fittings: The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet-pipe systems only) Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet-pipe systems only) (gasket sealed outlets shall not be used) Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 11 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler's inlet (wet-pipe systems only) (gasket sealed outlets shall not be used) Model F30R56 Dry sprinklers must not be installed into el- bows, welded outlets, or gasket sealed outlets. Installation of the Model F30R56 Dry sprinkler is not recommend in cop- per pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry-pipe system installations, the Model F30R56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 9 in this Bulletin. Do not install Model F30R56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruc- tion (see Fig. 11); this will damage the sprinkler, the fitting, or both. Model F30R56 Dry sprinklers are available with a short "FL" inlet fitting for installation on CPVC fittings of wet- pipe sprinkler systems only. Model F30R56 Dry sprinklers connected to wet-pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 10 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4" NPT and 1507-1 R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3 and F3R wrenches are designed to be in- serted into the groves in the sprinkler's wrench boss as shown in Fig. 12. The Model XL02 wrench is de- signed to fit into the cup and engage the wrench boss as shown in Fig. 13. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent damage to the sprin- kler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb- ft (30 - 40 N-m) for 1" NPT and IS07-1 Al sprinklers, and 14-20 lb-ft (19-27 N-m) for 3/4" NPT and 1S07- 1193/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F30R56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel: outer tube portion of the sprinkler (Item #8 in Fig. 16). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 - 40 N-m) for 1" NPT and ISO7-1R1 sprinklers, and 14-20 lb-ft (19-27 N-m) for 3/4" NPT and 1S07-1R3/4 sprinklers. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model Fl escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. Remove the orange protective clip when placing the sprinkler system in service. 17. Installation Data Sprinkler Suggested Hole Diameter in Required Centerline of Sprinkler Installation Model Escutcheon or Cover Plate Wall or Ceiling Tube/inlet to Finished Ceiling Wrench Vertical Dimension* Standard Escutcheon 2-1/8 (54 mm) F3 or F3R HB Extended Escutcheon 2-1/2 (64 mm) F30R56 Dry Pendent Not Applicable Fl R h t d Es cutcheon 2-1/4 (57 mm) ' FP Recessed Escutcheon XL02 2-1/2" (64 mm) CCP Cover Plate Standard Escutcheon 2-1/8" (54 mm) 4-5/8" to 12-5/8" HB Extended Escutcheon 2-1/2" (64 mm) (118 mm to 321 mm) F3 or F3R F30R56 Dry Fl Recessed Escutcheon 2-1/4" (57 mm) cULus, NYC Horizontal 4-5/8" to 6-5/8" Sidewall FP Recessed Escutcheon 2-1/2" (64 mm) (118 mm to 168 mm) Fl Recessed Escutcheon 2-1/4" (57 mm) FM XL02 FP Recessed Escutcheon 2-1/2" (64 mm) 4-5/8" to 12-5/8" (118 mm to 321 mm) * Based on 5/8" (16 mm) centerline of sprinkler tubefinlet to defector vertical distance. Maintenance The Model F30R56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sen- sitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: Sprinkler: [Model F30R56 Dry Pendent SIN R5714] [Model F30R56 Dry Horizontal Sidewall SIN R5734] Escutcheon/Cover Plate: [None][Standard escutch-. eon][Model HB extended escutcheon][Model Fl recessed escutcheon][Model FP recessed escutch- eon][Model COP cover plate - pendent only] Inlet Threads: [1" NPT][IS07-1R1][3/4" NPT][1507- 1R314] Inlet Fitting: [Long - Standard Inlet Fitting][Short "PL" - Wet Pipe Systems only] Sprinkler Temperature Rating: See Temperature Rat- ings table Sprinkler Finish: See Finishes Table Escutcheon/Cover Plate Finish: See Finishes Table Length: "A' Dimension (face of tee to face of ceiling or wall) in 1¼" (6 mm) increments - See Fig. 1 through Fig. 9 Note: The "A" dimension is based on a nominally gauged pipe thread "make-up" of .600" (15mm) per ANSI B2.1 [approxi- mately 7 1/2 threads]. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years,. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled 0 (800) 431-1588 Sales Offices ' Paper Reliabi (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. C (800) 848-6051 Sales Fax www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 10/16 P/N 9999970175 Description The recessed canopy has been widely accepted as the preferred method of finished sprinkler head installation. This type of canopy is one of the most ....., fi aesthetically pleasing by making the sprinkler less obtrusive. FPPI's recessed canopies are available in three standard finishes and two standard thread sizes. - - The threadable portion or retainer features 15 tines for maximum friction to the skirt or outer ring. Both the white and black finishes are polyester powder - ( coated for maximum durability as well as consistent color. Non-finished canopies are available for special color match requirements. --• -.. Installation Specifications Proper installation of the recessed sprinkler escutcheon can be accomplished with tools ordinarily found on the job site. The installer must make sure that the Type: Adj. recessed face of the reducing coupling must extend to within 3/4" of the finished ceiling material but no farther than flush with the finished ceiling. Thread the cup Standard threads: (retainer) by hand all the way on to the sprinkler head threads. Then install the 3/ "lPS 1/ " or 2 4 sprinkler into the reducing coupling at the end of the drop nipple according to Material: the sprinkler head manufacturers specifications. The skirt can be installed after .020" cold rolled steel the finished ceiling has been completed. Firmly push the skirt over the retainer until the skirt is firmly seated against the finished ceiling. Installation is now andard finishes: St rome complete. Brass White Black Adjustment range: 0-~" Coverage: 2 /8" 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1800 344-3775 © 2G 12 Fire Protection Products, Inc. ;.:, APPROVED LISTED -YsIi 007957 GS[ 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20 SS X 2-1/2 850 1.5 8010957 GST30 X 4 3-1/2 - 4* 1500 1.5 X 4 1475 1.5 8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 1500 1.5' 8021957 SWG 2Q_ X 2-1/2 3** 1250 1.5 8073925 SWG 20SS ' X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 X 4 1500 1.5 X 4 1475 1.5 UL Max Pipe UL Test [ FM Max FM Test Steel BX P/N STEEL UL Minimum Steel FM Minimum I Size, in. Load Pipe Size Load Thickness, in. Thickness, in. 5038957 DSTF1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 rBX P/N CONCRETE FM FM Max FM Test Material Pipe Size Load 8059957 CST 20 . X 4 147-r) innn PSI 8061957 SWC20 . X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" A7~ UL and FM tests were performed in compliance with NFPA-13 Standards. //7J'[iLj7 UI ex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. www.itwbuildex.com 800-284-5339 SSS26 0506 Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/411 and 11/411 Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2' and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4 (Fig. 66). Features - All steel construction eliminates structural deficien- cies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8' rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Fig. 65 Dimensions Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* Wt./100 3/8 1 /16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 1 /4 1130 55 5/8 11/2 3/4 1 9/16 1/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1 '/16 1V4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 1'/, 1130 55 5/8 1/2 1'/, 1 9/16 11/a 1130 55 * Max. loads for clamp with set screw in up or down position. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com Size Range - Secures 3/8' thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions 'Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod . Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing J Finish - Electro Galvanized I Note - Available in HDG finish or Stainless Steel materials. . Order By - Figure number .... . Fig. 99 - All Thread Rod Cut to Length Fig. 100 — All Thread Rod Full Lengths Size Range - Secures 3/8' thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1/4 8000 7140 360 1/2 11630 10370 510 Office/Manufacturing Facility • 1375 Sampson Ave." Corona, CA 92879 • Ph: 951.737.5599 • Fan: 951.737.0330 Customer Service • 800.786.5266 WWwtO!CO.Com Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2' thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650'F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/, 2 /8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3 /8 21/8 400 12 11/, 3/8 8mm or 10mm 33/, 21/ 400 13 1/2 3/8 8mm or 10mm 37/s 2/ 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/s 600 . 27 3 3/8 10mm 57/,4 600 29 31/ 3/8 10mm 7I 51/ 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/ 61/4 1250 66 6 1/2 12mm 101/8 6/4 1250 73 8 1/2 12mm 131/8 8/4 1250 -- 136 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fee: 951.737.0330 II Customer Service • 800.786.5266 www.tolco.com \ A - A / Dimensions 'Weights Rod Size A Length 3/8" Specify 1/2' Specify Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range - 3/8" and 1/2" rod; 4' thru 16" length.** Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Features - Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, rod or set screw size and length Note - Minimum return on Strap: 1". * Patent #5,947,424 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fan: 951737.0330 Customer Service • 800.786,5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2' pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed iy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 / ( i 2' 1' I; II H 1 \ Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951737.5599 • Fax: 951.7370330 A Customer Service • 800.786.5266 wwwtolco.com