HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS120109; Permit1/31/25, 4:16 PM AS120109 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS120109 Job Address: 5781 VAN ALLEN WY Permit Type: SPRINK Parcel No: 2121304400 Lot #: 0 Reference No.: PC #: Status: APPROVED Applied 9/12/2012 Approved: 9/26/2012 Issued: 9/26/2012 Inspector: Project Title: LIFE TECH LAB TI T.I. Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: THE G C NET LEASE (CARLSBAD) INVESTORS L L C C/O LIFE TECHNOLOGIES CORP 1600 FARADAY AVE CARLSBAD CA Fees ($) j Add'l Fees ($) Total ($) Balance ($) 272 62 334 0 about:blank 1/1 , nu ci\fl 13-232 INSTALLATION OF SPRINKLER SYSTEMS Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work Inspection and tests shall be made by the contractors representative and witnessed by the property owner or their authorized agent All defects shall be corrected and system taft in sefvice before contractors personnel finally leave the job A certificate shall be filled out and signed by both reptesentatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owners representative's signature in no Way prejudices any claim.against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name 1j c- T-1 L-M T ( IDat, 2AJ Property address S78l VIMJ Accepted by.approving authorities (names) . Address ( .. Plans Installation conformsto accepted plans . dyes U No EquIpment used is approved a-Yes No If no, explain deviations Has person in charge of iire.equlpment been Instructed as U Yes U No to location of control valves and care and maintenance - of thisnewequlpment? ..... . If no, explain Instructions .. ....... Have copies of the following been left on the premises? . U Yes U No S'stem components instructions UVes UNo daieii instructions UYes U No 3.NFPA25 . .. .. DYes 114o Lcatiofl of system Supplies buildings Year of Orifice Temperature Make Mode..äufacture size Quantity rating - ',tIKtP& . Vk302— ..___ Sprinklers .. . Pipe and Type Oiplpé Type Of fittings :........ . . . . . . . . . . . . .. . . fittings Maximumtimeto operate Alarm Alarm device through test connection valve or flow Type také Model, ,:..Minutes.-:.,. .... Seconds.. indicator ....., .. . ___._. Dry valve . . ... . . .. .Q.O.D. Make Model 1 Serial no. Make Model Serial no, Dry pipe Time to trip through test connectiona,b . Wa e pressure AIr piessiire Trip point air pressure Time water reached ... testo1Iet ,. . Alarm operated operating. test -. •. .-:. Minutes • Seconds . psi . ".....,, psi psi I Minutes Seconds Yes No - Without U.O.D. . .properly ... With . ... O.O.D. ., .. . If Ho, explain . . . 1.02009 National Fire .P.rote.dtiorAssqciaiion ........ . . NFPA 13 (p. 1 of 3) Measurec.Trom time lnspecors/tesi connection is operleu. b NFPA 13 only requires the SQ-second limitation in specif Ic. sections FIGURE 24.1 Contractor's Material and Test Certificate for Aboveground piping, . . 2010 Edition SYSTEMS ACCEPTANCE 13-233 Operation Pneumatic tEIastriô OH,drathicS Piping t,pesed DYes UNo Detectlngmethasupervised Uves UNo ,J Does valve operai1?TTr4heLanuai trip, remote, or both U Yes UNo control stations? D each circuit lain valves for tesung? Yes U No ;~Q-l Doeseach circuit operate Does eacrcuitpperate Maximum time to Make Model supervision loss alarm? valve release?-.. .. operate release Yes No Yes No Mint4çs Seconds l..oca ke and 1 Residual Pressure- and floor model c ressure (flowing) Flow rate reducing valve test _______ Inlet (psi) Outlet (psi) Flow (gpm) Outlet (psi)....Iet(Psi)f ( ,rostatic tests shall be made at not less than 200 psi (136 bar) for 2 hours or 50 psi (3.4 bar) -above-stfftic pressure in excess.of 150 psi (10.2 bar) for 2 hours. Differential dry pi p e v a l v e c l a p p e r s s h a l l b e l e f t open during the test to prevent damage. All aboveground piping leakage shall be stopped. Test ..,. .. description PnAIilntif.- Establish 40 psi (2.7 bar) air pressure and measure drop, which shal l n o t e x c e e d 1 ½ p s i ( 0 . 1 b a r ) in 24 hours, Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. All piping hydrostatically tested at .2Q. psi (—.- bar) for _.Z_ hours It no, state reason Dry piping pneumatically tested U Yes allo Equipment operates properly Ths C) No Do you certify as the spunkier contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not .usedfor testing systems or stopping leaks? Mf VZNes UNo Drain Reading of gauge located near water I Residual pressure with valve in test Tests test supply test connection: pi (-.----- bar) connection open wide: psi (— bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Verified by copy of the Contractor's Material and Test U Yes /lo Other Explain Certificate for Underground Piping. Flushed by installer of underground sprinkler piping C) Yes jNc It powder-driven fasteners are used in concrete, U Yes It no, explain has representative sample testing been satisfactorily completed? Blank testing Number d Locations Number removed gaskets 7 Welng piping -''es C) No It yes - -. Do you certify as the sprinkler contractor that welding procedures used c o m p l i e d w i t h Ales C) No the minimum requirements of AWS 82.1, ASME Section IX Welding and Brazing Qualifications, or other applicable qualification standard as required by the AHJ? Do you certify that all welding was performed by welders or welding operators ZLYOS U No qualified in accordance with the minimum requirements of AW S 8 2 1 , A S M E S e c t i o n IX Welding and Brazing Qualifications, or other applicable qualification standard as Welding required by the AHJ? Do you certify that the welding was conducted in compliance with a documented CUYes UNo quality control procedure to ensure that (1) all discs are retriev e d ; ( 2 ) t h a t o p e n i n g s i n piping are smooth, that slag and other welding residue are removed; (3) the Internal diameters of piping are not penetrated; (4) completed welds are free from cracks, Incomplete fusion, surface porosity greater than 1M in. diameter, undercut deeper than the lesser of 25% of the wall thickness or 1/62 in.; and (5) completed circumferential butt weld reinforcement does not exceed in.? 02009 National Fire iciation NIPA 13 (p.2 of 3) FIGURE 24.1 Continued 2010 Edition M-234 INSTALLATION OF SPRINKLER SYSTEMS Cutouts Do you certify that you have a control feature to ensure that Yes EaNO (discs) all cutouts (discs) are retrieved? Hydraulic Nameplate provided if no, explain data JU Yes UNo nameplate Sprinkler contractor removed all caps and straps? J1es UNo Date loft thsëAcé with all control iS.opi Remarks Name of sprinkler contractor csco c1c77C/j Tests witnessed by Signatures me,4perty owner .orjluthorized agent (signed) . . Title. Date tor (signedj Tifie Date Additional explanatd notes © 2009 National Fire Protection Association . . .NFPA ..(p.3 of ) FIGURE 24.1 Continued 2010 Edition San Diego Branch Office ..•••. I cosco 10695 Treena Street., Suite #105 I....,. San Diego, CA 92131 si..'; Fire (858) 444-2000 fax: 444-2056 Protection State License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date: 09/10/12 LIFE TECHNOLOGIES LAB T.I. 5781 VAN ALLEN WAY CARLSBAD, CA 92008 JOB # 10.CD_5415 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: M. KELLER Los Angeles • San Francisco 0 Orange • Fresno • San Diego 0 Seattle March 14, 2008 Sprinkler 41a The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 r t. Mpprov?u; Calendar INUIIIUI W-(D-I dflU ivit os--, voiume 10 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C 11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-NV, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° =A, 155°I68° = B, 175°/79° = D, 2000/93° = E, and 286°I141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F168 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/13. **A W' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flats Protective Cap 10896 Figure 1: Standard Sprinkler Wrench 10896W/B - Sprinkler Wrench 12144WB** for installing coated and/or recessed pendent sprinklers with protective caps *A 1/2° ratchet is required (not available from Viking). Carefully slide the wrench sideways around the protective cop, ensuring engage- ment with the sprinkler wrench flats. March 14, 2008 Sprinkler 41c MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary I 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286°F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d March 14, 2008 MICROFAST® AND 4Jl II 114rr1G; l:llE.rM MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler ' Thread Size ' Nominal Overall Listings and Approvals3 Base SIN [ K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.1 NPT BSP I U.S. I metiic2 Inches mm cULus' I FM- ( NYC' I VdS LPCB I (E I 0 Standard Orifice 06662B VK302 1/2' 15 mm [ 5.6 80.6 1 2-1/4" 58 AiX, B1Y I A3X, 133Y AIX, 131Y A3 A3X, 133Y C3X, E3Y13 C3X, E3Y'5 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AIX, B1Y A2X, 132Y AIX, 131Y -- A3X C313 -- 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- -- G3 -- -- - 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AIX, B1Y - Aix, B1Y A3 -- - -- Small Orifice' 067181310 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AIX, B1Y A2X Aix, B1Y -- - - - 06720B'° VK331 1/2" 15 mm 42 60.5 2-1/4" 58 AIX, B1Y -- AIX, B1Y - -- -_ 06932B VK331 -- 10 mm 42 60.5 2-3/8" 60 -- -- -- A3 -- G2" -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN - K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. meti1c2 Inches mm cULus4 FM NYC" Vd5 LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 Aix, B1Y - AIX - -- - -- Maximum 250 PSI (17 bar) WWP Small Orifice' 12290" VK342 1 1/2" 1 iS mm 2.8 1 40.3 2-3/16" 56 Aix, B1Y - AIX -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), Approved Finishes Approved Escutcheons X - Standard surface-mounted escutcheon or B - °C) 175 °F (79 °C) and 200 °F (93 °C) - Brass, Chrome-Enloy®, White Poly- the Viking Microfast® Model F-i Adjustable C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F ester78, Black Polyester71, and Black Escutcheon" (141 °C) Teflon®7 Y - Standard surface-mounted escutcheon or D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 "C), and 286 °F 2- Brass and Chrome-Enloy' the Viking Microfast® Model F-i Adjustable °C) (141 - : °% 3-Brass, Chrome-Enloy', White Polyester', Escutcheon12 or recessed with the Viking and Black Polyester' Micromatic® Model E-i or E-2 Recessed G - 155 °F (68 °C) Escutcheon Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by underwriters Laboratories Inc. for use in the U.S. and Canada. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 'Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.21K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the s.prinkler o be recessed behind the face of the wall or ceiling. ' (E Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 0832-CPD-2003. and 14 C € Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1 008. March 14, 2008 Sprinkler 41e The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com cULus Listing Requirements: Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aooroval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16" (583 mm) minimum 21/8" I 2-1/2" (63.5 mm) maximum (54 M) 1/2' (15 mm) NPT 1 2-1/4" 1-5/8" (58 mm) (41 mrs) _L L Pendent Sprinkler 06662B (VK302) 1-3/4" (44.5 mm) Installed with u standard 1/8" surface- mounted escutcheon. 2" -1/2"(38,1 mm) Maximum (50.8 mm) Minimum Installed with a Microfasi Model F-i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Sprinkler 41f March 14, 2008 MICROFAST® AND MicrofastHP® QUICK 'ii I I(IIS1G RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Serviôes 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 2-1/8" j Ceiling Opening Size: 2-1/8" I l 2-5/16" (58,7 mm) minimum (54 rim) (54 mm) 2-1/2" (63,5 mm) maximum 1-3/4" 11/8" (28,6 mm) (44.5 mm) Minimum Maximum ~Lj i Installed with a Micromatic Model E-1 Recessed Escutcheon \Ik II ,]J/1_1/8" (28,6 mm) (50.8 mm) \1JJ Minimum Maximum _________ Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE - Approval for Sprinkler 0666613, Added Dry System note in approval chart for Small Orifice.) Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-1 0/Schedule-40 gives you the extra quality assurance you demand. Our Sch-1 0(1-1/4" —8") pipe and Sch-40 (1" - 2-1/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements. Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM Al 35, Type E Grade A, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. —Sch 40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR fl ;m m ... i, t;kg/m biEkg . 1.049 1.680 2.05 1 J"25T 3.O5', 1¼" 1.380 2.270 2.93 1 r 436 11/2" 1.610 2.720 3.61 1 r---. ' 2.067 3.650 5.13 1 — 21/2" 2.469 5.790 7.86 1:73 1 62.7 Jj6 —Sch Nominal ID. LL!.Specifications Wt. Wt. (H20 Filled) CRR IiTmri I77 t?g/' I 1.442 1.810 '"r 2.525 :c- 7.0955 1.682 2.080 3.04 5.6570 I Z 2.157 2.640 4.22 4.5827 " 21/2" 2.635 3.530 5.89 3.5196 r6V.. T7TZ 3.260 4.330 7.94 2.5550 - p 4.260 r 5.610 11.78 y- 1.6020 5.295 7.77 17.33 1.4874 ri-257 77N37,7 6.357 9.290 23.03 1.0251 fl 1615 138 1 --. 8" 8.249 . 16.490 40.15 1.8365 :i APPROVED Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 5 T — QD - . -. . . .. . , - . Custorner Servce (800) 8825543.Fax:(8OO) 659-7730: .. '- 'wwvaIliedtube-sprinkler.ccm 0-' .,.. '* -. - .- - '. •t610GS Lathrop Ave.; .1350 NorcoFn Rd. .., 225 N 27thAve"' -' • 600 Dean Sievers Place. TUBE & CONDUIT , Harvey 1160426 -\ , Philadelphia PA 19154 - Phoenix AZ 85009 ' Morrisville PA 19067 . .. . 2OOB-1OTyco"int.'AiiRightseserved.STP-S5-4-1oo1. ... .. . . - . _.. - ...s .r - A .- A - C.I. THREADED FITTINGS FITTINGS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON r4p4 1 SIZE (INCH) CROSS ITEM MAX. I0lMSlONS CODE WORKING P.S.I. A B WEIGHT' EACH PIECE I CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 1112 CX055 300 1.94 1 1.94 3.10 -2 CX066 300 2.25 225 4.00 1 1/4X1 CX043 300=00 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST 7IIIRON IREDUCING NOMINAL ITEM MAX. DIM ENSIONS WBGIrr SIZE CODE WORKING EACH (INCH) P.S.I. A B C PIECE ______ 1XIX1I2 __CT331 300 1.26 1.26 1.26 0.95 1X1X314 CT332 300 1.37 1.45 1.10 1X1!2X1 CT313 300 1.50 TF 1.50 1.06 1X314X1 CT323 300 1.50 1 1.50 1.18 1X1X1 1/4 C1334 300 1.67 -17 1.58 1.52 - 1X1XI 1/2 C1 335 300 1.50 tF 1.65 1.73 I 114X1X1I2 CT431 300 1.34 1.53 1.17 1 1/4X1X3/4 CT432 300 1.45 1.37 1.62 1.38 1 114X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1(4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1!4X1X1 1/2 CT435 300 tr 1.80 182 2.05 I 114X1 1!4X112 CT441 300 134 1.84 1.53 1.37 1 114X1 1/4X3!4 CT442 300 14 1.45 1.54 1 1/4X1 1/4X1 CT443 300 tF 1.58 TT 1.65 1 1/4X1 1I4X1 112 CT445 300 1.88 1.88 ir 221 1 1/4X1 1/4X2 GT446 300 2.10 2.10 1ff - --9.3r I 112X1X112 CT531 301F 1.41 1.34 tB 1.41 1 112X1X3/4 CT532 300 --.52-1.37-1.75- 1.65 1 1/2X1X1 CT533 300 1.65 1.50 TO 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 200 1 1J2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1I4X112 CT54F 300 1.41 1.66 1.58 1 1/2X1 1/4X3!4 CT542 300 1.52 14 I75 --T.77- 1. 1/2X1 1/4X1 CT543 300 1.65 tF 1.801 1.85 1 1I2x1 1/4x1 1(4 --CTS-U- 300 1.82 tr 1.18 1 2.22 I 112x1 1/4x1 1/2 C1545 300 1.94 1 1.88 1.94 2.45 1 1/2X1 114X2 CT548 300 T11 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1.112X1 i/2X3/4 CT552 300 ThT 1.52 T 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 I 1/2X1 1/2X1 1/4 C1554 _300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 C1556 300 2.16 2.16 2.02 328 2X1X2 CT636 300 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.25 2.80 2X1 1/2X1I2 CT651 300 1.49 1.88 2.09 2X1 1/2X3/4 CT652 300 2.25 P1.41 1.60 1.97 2.40 2X1 1/2X1 CT653 300 1.73 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1!2 C1661 300"4 1.49 1.88 t 2.60 2X2X3/4 CT662 300 1.80 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 - 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 - 2x2x2112 I C1667 i 2.39 510 Page 39 C.I. THREADED FITTINGS FITTINGS © 9 LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PERASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TOASME B16.14. THREADS ARE NPT PER ANSI/ASME 8I.20.1. CAST1IIIRON III DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE * MAX. WORKING P.S.I. DIM IONS WBGHT A B EACH PIECE 1 CR90033 300 1.50 1.50 0.95 11/4 CB90044 300 1.75 1.75 1.34 1112 C890055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 21/2 CBM771 300 2.70 2.70 4.75 CAST IRON RED. COUPLING NOMINAL SIZE (INCH) ffBl CODE 4 MAX. WORKING P.S.I. DIM EgSION WBGHT EACH PIECE A 1X1/2 I CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 ICAST lIIRON 1RED. Iu1'] 3e ELBOW I NOMINAL I SIZE (INCH) ITEM CODE 4 MAX. 'DIMBIS JB WORKING P.S.I. WEIGHT' EACH PIECE A 1X1/2 C890031 300 1.26 1.36 1 0.64 I X314 C890032 300 1.37 1.45 1 0.87 1 114X112 C090041 300 1.34 1.53 0.98 1 114X3/4 C090042 300 1.45 1.62 1.13 1 114X1 C090043 300 1.58 1.67 1.16 1 112x1 1/2 CR90051 300 1.41 1.66 1.17 11/2414 C890052 300 1.52 1 1.75 1.28 1 1/2X1 CR90053 300 165 1.80 1 1.51 )j/2X1 1/4 CR90054 300 1.82 1.88 1 1.62 2X112 CR90061 300 1.49 1.88 2.00 2X314 CR90062 300 1.60 1.97 2.05 2X1 CR90063 300 1 1.73 2.02 2.10 2X1 1/4 C890064 300 1.90 2.10 2.30 2X1 1/2 1 C890065 300 1 2.02 1 2.16. 2.60 Page 38 ICAST IRON NOMINAL SIZE (INCH) ITEM CODE 4 STRAIGHTII MAX. P.S.I. WORKING ID IMENSIONSW EIGHT 1 CT333 300 11/4 CT444 300 11/2 CT555 300 2 CT666 300 21/2 CT777 300 CAST IRON 45 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE 4 ' MAX. WORKING P.S.I. IDIMENSIONS WEGHT I EACH B PIECE A I CB450331 300 1.12 1.12 084 11/4 CR45044 300 1.29 1.29 1.40 1112 CR45055 300 1.43 1 1.43 1.80 2 CR45066 300 1.68 1 1.68 2.79 CAST I RON NOMINAL SIZE (INCH) ITEM CODE 4 iPLUGS MAX WORKING P.S.I. __• DIMENSION A WEGI-Ir EACH PIECE 1/2 CPLOOI 300 0.94 0.10 3/4 CPLOO2 300 1.07 0.17 1 CPL003 CPLOO4 - 300 1.25 0.28 1114 300 1.36 0.44 1112 CPLOO5 300 1.45 0.62 2 CPL006 300 1.56 0.91 ,,•. •. . SA. FOR,'-.00D ••. .•. • 3 Not lens than Wood Flooring 2" nominal eidth No pre-drilling required. Quick to install using the Sammy Nut Driver with an I 8 cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.SA IVWattho vWeodemoOo,ar www.itwbulldex.com a. #14 Black Nut Driver Part# 8113910 i . #14 SW Red Nut Driver Part # 8114910 1/4" 8002957 GST 100 1/4 or 210 (7/16OSB) 25 125 83957 GST 200 114 x 2 170 j) 25. 12 .1 1/4" 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 [. 318" 8007957 GST 10 - 1/4x 1" 210 61 OSB)300 25 125 1" 3/8" 8008957 GST 20 1/4 x 2 1760 (Fir) 850 1475 25 125 3/8" 88925 GStOi[4 x 2" 1760 (Fi/ - 25 12 I 3/8" 8009925 GST 25-380 318x2-1/2 2113 (Fir) 1500 25 125 .81957 GST 30 174 x 2" 2060 Fir) 1500 1475 25 12 i 3/8" 8069925 GST 30-SS 1/4 x 3 2060 (Fir) 25 125 38 815 0ST40 x4" 2180Fif) 25 157 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8Q14925 GST MW x1/2" 2113 WJ 25 125 1/2 8015925 GST 3 1/4 x 3 2275 (Fir) 25 125 :vs SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing intO, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ~~AMMU70 No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Not less than 2' nominal width (1-1/2') up to 3-11T pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe Floor Joist I Minimum 2-1/2' from ttorn for branch lines. Minimum 3' from bot- tom for main lines. Exception: This requirement shall not apply to 2' or thi 7T cker nailing ottips resting on top of steel beams. TI Watat a rdeo emoat,a0su at www.ftwbulldex.com 1/4' 8019957 3/8'; 802057 -[ 3/8" 8021957 3/8' 8073925 3/8" 8022925 #14 SW Red L 3J5' 802392w Nut Driver Part #8114910 * May require pre-drilling; consult joist manufacturer. SWG 200 1/4 x 2' 1725 (Fir) 25 125 SO 10 1/4x1 622_() 300 25 12 SWG 20 1/4x 2' 1725 (Fir) 1050 25 125 WGS 1142' 1725 (Fir) 850 25 125 SWG 25-380 3/8o 2-1/2' 2249 (Fir) 1500 25 125 0 COMM No 0. 'Eliminates distortion of threaded rod. Accommodates up to 3 /" x 12 pitch roof. 'Allows 17' deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. l#14 Black - 3/8' 8139957 SH-GST20 114x2 1257 (Fir) 1050 1475 25 125 NutDriver art#8113910 IT $fitST 30 1/4 3 1 1903 Dim. Lumber 1500 3/8" 8269957 SH-GST/CST20 5/16x1-3/4 1406@4505 vertical 25 125 Dim. Lumber Lumber 1/2 83O957 SNGST1CST20.5rt6x1 3/441Offerlicul May require pre-dtiltng; consult jniot manufacturer. #14 SH Orange Nut Driver Part #8273910 'I. Inch pipe 5 thru 8 Inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 3/4 thru 4 Inch pipe LISTED FOR STEELJCPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - C®LJS 203-EX 2551 <8> Approval guide - Pipe Hangers OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW.-H- 171 Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. NFPA 13 PIPE ROD MAX REC. LOAD LBS. METRIC REFERENCE 3/4 3/8 400 20 1 3/8 400 25 11/4 3/8 400 32 1 1/2 3/8 400 40 2 3/8 400 50 21/2 3/8 600 65 3 3/8 600 80 3112 3/8 600 4 3/8 1000 100 5 1/2 1250 125 6 1/2 1250 150 8 1/2 1250 200 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS — c 1 us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When Installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or banger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances wbalsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 650 ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 1 4960 4420 1 1/4 8000 7140 11/2 1 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru 1 1/2 inch rod in 10' - 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. ORDERING - Part #, rod diameter and finish. 1/08 FireLock® Outlet-I Read and understand all instructions before attempting to install any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in serious personal injury and/or property damage. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Failure to follow this instruction could result in serious personal injury and/or property damage. The Style 922 FireLock Outlet-T is designed for direct connection of sprinkler heads, drop nipples, sprigs, drains, gauges, and other outlet products. The Style 922 FireLock Outlet-I is UL Listed and FM Approved up to 300 psi/2068 kPa and VdS Approved up to 16 Bar/232 psi at ambient temperatures that are typical for fire protection systems. PRODUCT DATA Y 6 F Z- V.4 T -1-1 1 1., -1 i'A .83 flO 'W 10 T 32 15 30.2 1 33.0 45.5 27.9 983 65.0 0.45 20 30.2 1 325 46.5 25 30.2 1 38.6 55.4 27.9 98.3 65.0 0.54 1½ ½ 1 'A 1.42 1.95 122 .08 1 2.56 1.2 40 15 30.2 , 36.1 493 31.0 103.61,0,, 0.54 '/4 1 3M 1.40 1.95 1.22 4,08 f 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 - ---------r----+------' -' ---- 1 1/ 1.64 2.30 1.22 4.08 2.56 13 25 30.2 , 41.7 , 58.4 , 31.0 - 103.6 65.0 0.59 2 ½ 1 T/, 1.66 1 2.19 r 1.46 4.50 1 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ------- r- 3A 1 3A 1.64 2.19 1 1.46 4.60 2.56 - 1.4 20 30.2 41.7 55.6 - 37.1 - 116.8 65.0 0.64 1 1 1.88 2.54 1.46 4.60 -i 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65- .. 'L i ._ 216 ½ 1 3,j 1.91 1 2.44 1.71 5.40 , 2,56 1.6 65 15 30.2 1 48.5 _J 62.0 43.4 137.2 65.0 0.73 3/~ 1,-i, 1.89 2.44 1,71 5.40 2.56 1.6 20 30.2 48.0 I 62.0 43.4 137.2 65.0 0.73 ...............- -------------------------4 .......- .... 1 1~ 2.13 2.79 1.71 5.40 2.56 1.6 25 302 54.1 70.9 43.4 1372 65.0 0.73 ___________ .----------i------------ ---------H - - - ½1 3,4, 1. 91 2,44 1.71 5.50 2.56 1.6 76.1 mm x 15 30.2 48.5 62.0 43.4 139,7 65.0 0.73 3/4 1.89 1.6 20 30.2 48.0 62.0 43.4 139,7 65.0 1 0.73 _J__44 1 1.71 5.50 1 .56 11 --..----- 1 1 3,43 2.13 2.79 1 1,71 1 5.50 2.56 I 1.7 25 30.2 54.1 70.9 I 43. i 139,7 - 65.0 i 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (Optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinkler heads, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com JtauIic VIcTAuUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2004 VITALIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV,C -9221 Exaggerated for clarity 2. Ensure that a ½-inch/13-mm area around the hole is clean, smooth, and free from indentations and/or projections that could affect gasket sealing (refer to the sketch above). Remove any burrs and sharp or rough edges from the hole that might affect assem- bly, proper seating of the locating collar, flow from the outlet, or gasket seating. INSTALLATION 1. Install the gasket into the gasket pocket, as shown above. Press the gasket along the full circumference to ensure that it fully seats in the gasket pocket. DO NOT LUBRICATE THE GASKET. 3. Install the outlet housing onto the pipe by centering the locating collar in the hole. To check for proper engagement, slide the outlet housing back and forth while pushing down. A properly positioned outlet housing can be moved only a small amount in any direction. 3a. Rotate the lower housing around the pipe, while holding the outlet housing in place to make sure the locating collar remains seated properly in the hole. - a. INSTALLATION INSTRUCTIONS 1-922 FireLock® Outlet-T STYLE 922 PIPE PREPARATION NOTICE Victaulic hole cutting tools are recommended for proper hole preparation. 1. Cut a hole on the centerline of the pipe. Refer to table on page 1 for hole requirements. 2. Insert a bolt into the outlet housing and lower housing, and thread a nut loosely onto the bolt (nut should be flush with end of bolt) to allow for the swing-over" feature, as shown above. 4. Insert the other track bolt into the outlet housing and lower housing. Install the nut finger-tight. www.victaulic.com \ Ant-aulid vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2004 VICTAuLIc COMPANY. All RIGHTS RESERVED. PRINTED IN THE USA. I-922_2 REVC 1-922 INSTALLATION INSTRUCTIONS FireLock® Outlet-T STYLE 922 5. Tighten the nuts evenly to an approximate torque value of 20ft-lbs/27.1-Nom to ensure proper gasket compression. NOTE: To avoid over-tightening the nuts, use a wrench with a maximum length of 8 inches/200mm. DO NOT over-tighten the nuts. The outlet housing, near the gasket, should not make metal-to-metal contact with the pipe. In addition, a small gap is expected between the outlet housing and the lower housing, as shown above. DO NOT over-tighten the nuts. Over-tightening the nuts can over-compress the gasket and distort the outlet housing and lower housing. Over-tightening does not enhance product per- formance. Failure to follow this instruction could cause product failure, resulting in serious personal injury and/or property damage. www.victaulic.com jtaukc VICTAULI IS REGISTERED TRADEMARK OF VICTAUUC COMPANY. © 2004 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. ______________ REVC 1-922_3 STYLE 922 II 111111111111111111111111111111111110 WCAS-65GJLA For complete contact information, visit www.victaulic.com .J(tauIic 1-922 3393 REV C Z100922000 UPDATED 3/2004 VICTAULIC IS REGISTERED TRADEMARK OF v!cTAuuc COMPANY. C 2004 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. -922