Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS090082; Permit4/4/25, 7:44 AM AS090082 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090082 Job Address: 5781 VAN ALLEN WY Status: ISSUED Permit Type: SPRINK Applied 7/17/2009 Parcel No: 2121304400 Approved: 7/17/2009 Lot #: 0 Reference No.: Issued: 7/17/2009 PC #: Inspector: Project Title: LIFE TECHNOLOGIES T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON P0 WAY CA 858-513-4949 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance 130 0 130 0 about:blank 1/1 I WEIErJ PRDTE C11 11 F'J Western Fire Protection Inc. LIFE TECHNOLOGIES TENANT IMPROVEMENT Western Job # C-2612 Materials Submittal Automatic Wet Pipe Sprinkler System Provide Stamps For Approval In Space Below 13630 Danielson Street 9 Poway, CA 92064 • Phone: (858) 513-4949 9 Fax: (858) 513-1322 go SECTION DESCRIPTION PRODUCTS 1. SPRINKLER HEADS A. GLOBE UPRIGHT #GL5661 2. PIPING, FITTINGS & MECHANICAL COUPLINGS ALLIED DYNAFLOW STEEL PIPE ALLIED DYNATHREAD STEEL PIPE SMITH COOPER CAST IRON THREADED FITTINGS VICTAULIC COUPLINGS & FITTINGS 3. PIPE HANGERS & SUPPORTS RING HANGERS - TOLCO #200 ALL THREAD ROD - TOLCO #100 SURGE RESTRAINER - TOLCO #25 TOP BEAM CLAMP - TOLCO #65 CONCRETE ANCHOR - RAMSET #RL-38 PIPE CLAMP - TOLCO#4 SEISMIC BRACE - TOLCO#1 000 SEISMIC BRACE ATTACHMENT - TOLCO#980 SEISMIC BRACE ATTACHMENT - TOLCO#800 *MATERIALS MAY BE SUBSTITUTED WITH LISTED EQUAL DUE TO PRODUCT AVAILABILITY LOBE FIRE SPRINKLER CORPORATION rM A UTOMA TIC SPRINKLE- Is-GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTIONAND OPERATION The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are UUPRIGHT specified This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements. CONVENTIONAL The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. . V r-- . PENDENT VERTICAL TECHNICAL DATA SIDEWALL See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C). . ...... Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). . Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze o Deflector - brass o Screw - brass Bulb seat - copper o Spring - nickel alloy o Seal - teflon HORIZONTAL SIDEWALL Bulb - glass with glycerin solution, 5mm size. SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE BULB COLOR N.FRA. MAXIMUM SPRINKLER TEMPERATURES CEILING TEMPERATURE ORDINARY FfI5F 57°C.I687C ORANGE/RED 100 F 38-C INTERMEDIATE 175FJ200 F 7 °C'93 °C 1 YELLOW/GREEN 150 F Sb C HIGH 28 °F 141 C BLUE 225F ., 1 07'C EXTRA HIGH 3o0F J.3ç.. MAUVE . 300F 49 C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 NOVEMBER 2000 A-65 BULLETIN GL5661 rm A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES 2.8 (39 metric) 1/2' NPT 2 114" (5.7 cm) Factory Bronze Chrome 4.2 (59 metric) 1/2 NPT 2 1/4" (5.7 cm) Bright Chrome White Polyester+ 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester-f 7.8 (III metric) 1/2" NPT 2 114" (5.7 cm) Wax Coated Lead Coated 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)**:Wax over Lead NOTE: METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS HORIZONTAL SIDEWALL IS2 9116. FINISHES AVAILABLE ON SPECIAL ORDER. WAX COATING UL LISTED UP TO 2007 ONLY. + AVAILABLE AS UL AND C-UL LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. SIN ORIFICE 135°F 155°F 175°F 200°F 286°F 360°F STYLE MODEL SIZE 57°C 68°C 79°C 93°C 141°C 182°C cULus FM GL2861 2.8 X X X X X X X GL4261 4.2 X X X X X X X - UPRIGHT GL566I 5.6 X X X X X X X X GL8 161 7.8* X X X X X X X X GL8164 8.1 X X X X X X X X GL285I 2.8 X X X X X X X - GL4251 4.2 X X X X X X X - PENDENT GL5651 5.6 X X X X X X X X GL8151 7.8* X X X X X X X X GL8156 8.1 X X I X X X X X X VER11CAL GL5675 5.6 X X X X X X X X SIDEWALL t GL8 176 8.1 X X X X X X X - GL2870 18 X X X X X X X - HORIZONTAL GL4270 42 X X X X X X X SIDEWALL § GL5670 5.6 X X X X X X X X GL8171 8.1 X X X X X X X CONVENTIONAL GL5668 5.6 X X X X X X -- - (OLD STYLE) GL8 169 8.1 X X X X X X -- - HORIZONTAL SIDEWALL UL LISTED FOR DEFLECTOR 4' TO 12' BELOW THE CEILING, FM APPROVED 4" TO 6'. t VERTICAL SIDEWALL UL LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL UL LISTED FOR 6' MIN. SPACING. ORDERING INFORMATION UPRIGHT VERTICAL SIDEWALL UL LISTED FOR 9' MIN. SPACING. SPECIFY 1/2" NPT. -Quantity • Model Number • Style GLOBE® PRODUCT WARRANTY Orifice • Thread Sizes • Temperature Globe agrees to repair or replace any of its own manufac- Finishes desired tured products found to be defective in material or workman- Quantity - Wrenches - P/N 325390 (1/2"); ship for a period of one year from date of shipment. P/N 312366 (L.O.) For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 1 GINN LOBE 4077 AIRPARK DRIVE STANDISH MICHIGAN 48658 CORPOIAT1ON 989-846-4583 FAX 989-846-9231 -_ 1-800-248-0278 www.globesprinkIer.com NOVEMBER 2000 PRINTED U.S.A. BULLETIN GL5661 Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcsl WI/Lift (21') WI/liD (241) Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2' 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3,387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 I Additional Benefits EM TW Dyna-FIoW® High Strength Steel Pipe The original high-strength light wall sprinkler pipe with hydraulics superior to Schedule-:LO. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." -Coating-i:1Fabrication1 Dyna-Flow products are coated with an environmentally approved and, specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. S <~> 9 Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tqco/Row Control 'Y all • 16100 S. Lathrop • Harvey, IL 60426 Customer Service: ied 11350 Norcom Rd. Philadelphia, PA 19154 (800) 882-5543 TUBE &CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S2-3 EW 31 DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. .-Comparison to Schedule 4O_ Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. @ <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR4.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40fDyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and IJLC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specificationsi NPS Nominal I.D. Wt. WI. (H20 Filled) Pc WI/Lilt (21') WI/Lilt (24) WI/Lilt (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 11/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/2' 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 tqco/F/ow control (•") cIIjeçJ 16100 S. Lathrop ' Harvey, IL 60426 Customer Service: 11350 Norcom.Rd. Philadelphia, PA 19154 (800) 8825543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 <@> SMITH - COOPER I N T R N AT I 0 N A L Cast Iron Threaded Fittings Ui. US * ALL FITTINGS 100% AIR TESTED * ANSI B16.4 * ISO 9002 MANUFACTURER * ASTM A126 FM. LISTED * LISTED/APPROVED AT 300 PSI * ANSI B 1.20.1 APPROVED Cast Iron 900 Elbow Figure 37E L Size A Wgtllbs. 1/2 1.26 0.40 3/4 1.31 0.60 1 1.50 0.92 1-1/4 1.75 1.44 1-1/2 1.94 1.95 2 2.25 3.13 2-1/2 1 2.70 1 4.94 Cast Iron Reducing 901 Elbow Figure 37RF Size A B Wgtllbs. 1 x 1/2 1.36 1.26 0.67 1x3/4 1.45 1.38 0.76 1-1/4x1/2 1.53 1.34 1.07 1-1/4x3/4 1.63 1.45 1.02 1-1/4x1 1.67 1.58 1.21 1-1/2x1/2 1.75 1.52 1.53 1-1/2x3/4 1.75 1.52 1.55 1-1/2x1 1.80 1.65 1.44 1-1/2x1-1/4 1.88 1.82 1.74 2x 1/2 1.97 1.60 2.22 2x3/4 1.97 1.60 2.20 .2x 1 2.02 1.73 2.08 2 x 1-1/2 2.16 2.02 2.59 Cast Iron 45° Elbow Figure 37F bA Size A Wgtllbs. 1 1.26 0.83 1-1/4 1.29 1.33 1-1/2 1.44 1.79 2 1.69 2.89 Cast Iron Tee Figure 37T f_I *-A -- Size A Wgt/Ibs. 1/2 1.13 0.56 3/4 1.31 0.84 1 1.50 1.25 1-1/4 1.75 2.03 1-1/2 1.94 2.70 2 2.25 1 4.23 Cast Iron Hex Reducing Coupling Figure 37RC I ,Lr --r( I t ~ Size A Wgt/Ibs. lx 1/2 1.69 0.54 1x3/4 1.69 0.63 2x1 (not hex) 2.81 1.83 <§>SMITH - COOPER INTERNATIONAL <@~> C ® Cast Iron Threaded Fittings * ALL FITTINGS 100% AIR TESTED *ANSI B16.4 * ISO 9002 MANUFACTURER * ASTM Al2 LISTED * LISTED/APPROVED AT 300 PSI B 1.20.1 APPROVED 91 Cast Iron Reducing Tee Figure 37RT -4--A -0- _F -4--B -0- I - __j Size A T 1x1/2x1 1.50 1.36 1.50 1.08 1x3/4x1 1.50 1.45 1.50 1.13 1x1x1l2 1.26 1.26 1.36 1.01 1x1x314 1.38 1.38 1.45 1.11 1-114x112x1-114 1.75 1.53 1.75 1.64 1-114x3/4x1-114 1.75 1.62 1.75 1.73 1-1/4x 1 x1/2 1.34 1.26 1.53 1.27 1-114x I x314 1.45 1.38 1.63 1.36 1-1/4x 1 x 1.58 1.50 1.69 1.53 1-1/4 x1x1-1/4 1.75 1.69 j 1.75 1.79 1-1/4 x 1-1/4 x 1/2 1.34 1.341 1.53 1.47 1-114x1-1/4x314 1.45 1.45 1.62 1.57 1-1/4x1-1/4x1 1.58 1.58 1.67 1.73 1-1/2x1/2x1-114 1.81 1.56 1.88 1.93 1-1/2x112x1-1/2 1.94 1.68 1.94 2.14 1-112x314x1-1/4 1.94 1.66 1.88 2.11 -1/2x3/4x1-1/2 1.94 1.75 1.94 2.18 -1/2x1x112 1.44 1.25 1.69 1.75 1-1/2x1x314 1.50 1.441 1.75 1.70 1-1/2x1x1 1.65 1.501 1.80 1.72 1-1/2x1x1-1/4 1.82 1.67 1.88 2.08 1-1/2x1x1-1/2 1 1.80 1.94 2.29 1-1/2x1-1/4x1/2 1.41 1.34 1.66 1.67 1-112x1-114x3/4 1.52 1.45 1.75 1.79 1-1/2x1-1/4x1 1.65 1.58 1.80 1.97 1-1/2x1-1/4x1-114 1.82 1.75 1.88 2.28 1-1/2x1-1/4x1-1/2 1.94 1.88 1.94 2.50 1-1/2x1-1/2x1/2 1.41 1.41 1.66 1.84 Cast hon Reducing Tee Con't Figure 37RT Size T T 1-1/2 x1-1/2x3/4 1.52 1.52 1.75 1.95 1-1/2x1-1/2x1 1.65 1.65 1.80 2.13 1-112x1-1/2x1-1/4 1.82 1.82 1.88 2.44 2 x I x 2 2.25 2.02 2.25 3.46 2 x 1-1/4 x 2 2.25 2.10 2.25 3.71 2 x 1-1/2 x 1/2 1.49 1.41 1.88 2.34 2 x 1-1/2 x 3/4 1.60 1.52 1.97 2.46 2 x 1-1/2 x 1 1.73 1.65 2.02 2.66 2x1-1/2x1-114 1.90 1.82 2.10 2.98 2x1-1/2x1-1/2 2.02 1.94 2.16 3.24 2 x 1-1/2 x 2 2.25 2.16 2.25 3.70 2x2x1/2 1.49 1.49 1 1.88 2.74 2x2x3/4 1.60 1.60 1 1.97 2.86 2x2x1 1.73 1.73 2.02 3.05 2x2x1-1/4 1.90 1.90 2.10 3.38 2x2x1-1/2 r2.02 2.02 2.16 3.59 Cast Iron Bull Head Tee Figure 37BT -4---A Size A B C 1 xix 1-1/4 1.67 1.67 1.58 1.49 1-1/4x lx 1-1/2 1.88 1.80 1.82 2.07 1-1/4x1-114x1-1/2 1.88 1.88 1.82 2.29 1-1/2x1-1/4x2 2.16 2.10 2.02 3.07 1-1/2x1-1/2x2 2.16 2.16 1 2.02 3.23 2 x 2 x 2-1/2 2.60 2.60 2.39 1 5.17 All Weights in Pounds Smith-Cooper International 1057 So. Vail Ave., Montebello, CA 90640 Tel: (323) 890-4455, (800) 766-0076 Fax: (323) 890-4456 www.smithcooper.com Patented FireLockTM Style 005 rigid coupling has a unique, pat- ented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 DIMENSIONS Rated for wet and dry sprinkler systems at 350 PSI (2413 kPa) for 11/4 - 4 (42,4 - 114,3 mm) sizes and 300 PSI (2068 kPa) for 41/4 - 8 (108,0 - 219,1 mm) sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expan- sion, contraction or angular deflection. rAW \jttauIic® An 9001 certified company A, H Wn. M ~ P: -, ~ & -, Style 005 VIcA TM Gasket System reLock Rigid Coupling with Vic-Plus- Gasket System PRODUCT DESCRIPTION Sprinkler Systems. Angle- pad design permits assem- bly by removing one nut/ bolt and swinging the housing over the gasket. This reduces components to handle during assembly-, speeds and eases installa- tion on pipe grooved to Victaulic specifications. Style 005 FireLock cou- plings with the Vic- Plus Gasket System are designed and rec- ommended for use § LPC and VdS Approved, see notes on page 2. ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic® now offers a gas- ket system which requires no field lubrication. The Vic-Plus System (patent pending) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. 10.021O SIZE Max. Max. Allow. Dimensions Nominal Work. End Pipe End @ BoltiNut Inches/mm Aprx. Inches Press. § Load Sep. t No. -Size Wgt. Ea. Actual elm PSl1IkPp Lbs .*/14 InJmnmn Inches/mm X Y Z Lbs Jkg 11/4 350 755 0.05 2.75 4.50 1.88 1.2 42,4 241i. 3271) 1.2 2-/8 X 2 - 11/2 350 990 0.05 2-%X2 3.00 4.75 1.88 1.2 '21 148 1)5 2 350 1550 2cc 0.07 2-%X21h 3.50 5.25 1.88 1.6 30.2 i 148 07 21h 350 2270 0.07 2-%X 2/s 4.00 5.75 1.88 1.9 102 1:2. 148 341. 76,1 mm 350 2475 0.07 2-VaX 2/2 4.13 5.75 1.88 1.9 212 -i: 148 1.18 '' 2 -%X2/s .13 6 I' 1 4 350 5565 0.16 1 2-%X2/s 5.75 7.25 2.13 3.1 1)413 34771). I-U) 134 54 108,0 mm 300 4255 0.16 1 2 -% X 2/s 5.63 7.25 2.13 3.1 205'). ., 1"3 154 )4 5 300 7290 0.16 2½X2~88 00 2 4.5 133,0 mm 300 6495 0.16 2- ½ X 23/4 20 6.63 9.00 2.13 4.5 ,, 139,7 mm 300 7125 0.16 2-½X2A 6.88 900 2.13 4.8 221) 54 6 13')..) 300 2052 10340 4802Cr 0.16 2-/2X2Y4 8.00 21)5 10.00 2c4 2.13 5.0 2.3 159,0 mm 300 9200 ;-r 0.16 2-%X41/4 7.63 10.00 2.13 5.5 . 165,1 mm 300 9955 0.16 . 2-½X2/ 8.15 10.00 2.13 5.5 2 5- 4 '3 8 300 75 0.192-% X 41/4 10.50 13.13 2.63 11.3 67 @ § t Refer to notes on page 2. Victaulic® World Headquarters • P.O. Box 31, Easton, PA 18014-0031 • 4901 Kesslersville Rd., Easton, PA 18040 • 1-800-PICK VIC • FAX: 610/250-8817 • www.victaullc.com 1538 Rev.E 10100 0 Registered Trademark of Victaulic © copyright 1999 Victaulis Printed In U.S.A. EN 71 MATERIAL SPECIFICATIONS Housing: Ductile iron conform- ing to ASTM A-395, grade 65- 45-15, and ASTM A-536, grade 65-45-12. Housing Coating: Orange enamel Optional: Hot dipped galva- nized Gasket: Grade "E" EPDM - Type A Vic-Plus Gasket System t (Violet color code). FixeLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler ser- vices up to the rated working pressure using the Grade °E" Type A Vic-Plus Gasket System, requiring no field lubrication. For dry services, Victaulic continues to recommend the use of Grade "E" Type A F1ushSeal5 Vic-Plus Gasket System. Contact Victaulic for details. Bolts/Nuts: Heat treated car- bon steel, zinc electroplated to ASTM B-633; Track head bolt conforming to ASTM A-183 minimum tensile 110,000 PSI (758340 kPa); Flanged hex nut conforming to ASTM A-563, Grade A. t Standard gasket and FlushSeat gasket approved for dry pipe systems to -40°F (-40°C). Supplemental lubricant Is rec- ommended for services installed at or continuously operating below 0°F (-18°C). Victaulic continues to recom- mend the use of FlushSeat gaskets for dry services. The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 1D.02.2A Rated Working Pressure Rated Working Pressure Pipe Schedule Size Inches UL ULC FM Pipe ] Schedule1 Size Inches UL ULC FM 5 1¼-3 175 175 175 EZ 4 300 300 300 10,40 P14-4 350 350 350 6 175 175 175 5-8 300 1 300 300 SF 1'/4-4 300 300 300 BLT 11/4 2 300 300 300 Super 40 11I42 300 300 300 DF 114-4 300 300 300 IL 11/4 2 300 300 300 6 175 175 175 WLS 11/4 2 300 300 300 DT 1114 2 300 300 300 XL/XL-II 11/4 3 300 300 300 EL 114-2 300 300 300 NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe. 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. ELT refers to Listed/Approved steel sprinkler pipe manufactured by American Tube Company. DF refers to Listed/Approved Dyne-Flow steel sprinkler pipe manufactured by American Tube Company. DT refers to Listed/Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Listed/Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. Super 40IXL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tithe Company. XL/XL-fl refers to Listed/Approved XL or XL-ll steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. NOTES ° Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. © Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI). WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic company. All products shalt be Installed in accordance with current Victaulic installation/assembly instructions. Vlclaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.90-2 Independent testing has shown the Style 77 cou- pling to be an effective stress relief and vibration attenuation device provid- ing performance superior to braided steel and elasto- meric arch-type connec- tors when used in close proximity to the source of vibration. Refer to 26.04 for vibration information. Independent testing has shown that Victaulic Style 77 and 75 flexible couplings and Style 07 Zero-Flex® rigid couplings provide exceptional functionality during and after earth- quake conditions. Refer to 26.05 for further informa- tion. Vic-Plus Gasket System: Victaulic® now offers a gas- ket system which requires no field lubrication. The Vic-P1us System (patent pending) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. DIMENSIONS 3/4 - 12" Sizes / \/iCtaUliC® Style 77 A:9O0l certified company sket System Standard Flexible Coupling PRODUCT DESCRIPTION with VicPIusTM Gasket System Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pres- sure piping systems. Sizes 3/4 -12 (26,7 - 323.9 mm) are two-piece housings. Sizes 14 - 22" tJA4 (355,6 - 559,0 mm) are cast <!> in four identical segments, with larger sizes cast in six segments. This eases han- dling and assures concen- tricity. All sizes are provided with plated bolts and nuts. Gal- vanized and stainless steel housings are also available. 05.04-19 Max. Max. Allow. Deflect. Fr. Dimensions Aprx SIZE Nominal Work End Pipe CL Bolt/Nut lnches/imturnetes w9t. Per Pipe Inches Pres. Load End t No. -Size Each Actual PSI*Lbs.* Sep. Cplg. In./Ft. Inches Lbs. inrn iPa N In./mm Deg. nrnimn Inst X V Z kg 3/4 1,000 865 0-0.08 , 3-24 0.72 2/eX2 2.13 4.00 1.75 1.1 21,7 :.rs,j °4 102 .4 0.5 1 1,000 1,360 0-0.06 , 2 -43 0.57 2- /sX2 2.38 4.12 1.75 1.2 34 ocj .-y 11/4 1,000 2,160 0-0.06 , 2-10 0.45 1 2hX2h 2.65 5.00 1.88 2.0 ,,•, .; i'7 t3 00 1½ 1,000 2,835 0-0.06 , 1-56 0.40 1 1/6 2-hX2 3.13 5.38 1.88 2.1 5s :-. 137 49 1.0 2 1,000 4,430 0-0.06 , 1-31 0.32 1 1 2/1X2/2 3.63 5.88 1.88 2.6 14-: I$1t"i 117- , a .i•. .2 ? : .000 6,490 1° 15' 26 2- ½ X 23/4 4.25 6.50 1:88 3.1 30.0. 1,000 7,070 0-0.06 , 1-12 0.26 2-/2X2~ 4.38 6.63 1.88 3.2 . ::. :y ,, j 3 1,000 9,620 0-0.06 1°-2' 0.22 2- ½ X 2Y45.00 7.13 1.88 3.7 31h 1,000 1 12,565 0-0.06 0° -54' 0.19 2- 5/a X 31/4 5;3 5 1:88 5.6 4 1,000 15,900 0-0.13 1°-36' 0.34 2s/aX 3¼ 88 2.13 6.7 4¼ 0.0. 1,000 14,180 0-0.13 , 1-41 0.35 6.00 8.63 2.13 11.0 1:14.0 0-4,2 "' a.v jip s-i ,j 5 1,000 24,300 0-0.13 , 1-18 0.27 3 2/4X4/4 7.75 10.65 2.13 10.6 14 .2 1q10 '2120 0-3,2 17f) 54 42 51/4QQ 1,000 21,635 0-0.13 , 1 -21 0.28 7.63 10.38 2.13 10.0 002S 0-2.2 21 FA 21St 1'4 1,1. 5½0.D. 1,000 23,745 0-0.13 , 1'- 18 0.28 .. ... •.- 8.63 10.65 2.13 10.0 114,7 095) 0'5005 ('-3.2 '' 22 270 5.4.5 6 1,000 34,470 0-0.13 , 1-5 0.23 2-/4X41/4 8.63 11.88 2.13 12.0 341 5(10) t5'3'. r.12 . 22 .31)2 5.1 54 61/4 0.0. 1,000 30,665 0-0.13 1-91 0.24 .,.., . .- '. 8.63 11.50 2.13 13.2 61/2 0.0. 1,000 t 33,185 0-0.13 , 1-6 0.23 2 • 2-4A /4 X 8.88 11.63 2.13 13.2 165.1 39114 i-fl345 0-2.2 8 § 800 46,740 0013 0°-50' 18 2-/e X 5 00 14.75 2.50298 Table continued on page 2. °t@ Refer to notes on page 2. Viclaulic® World Headquarters • P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesstersviie Rd., Easton, PA 18040 • 1-800-PICK VIC • FAX: 610/250-8817 • www.victaulic.com 1469 Rev.c 10/00 0 Registered Trademark of VictauliC 10 Copyright 1999 Victaulic Printed In U.S.A. 14-22"Sizes El 24" Sizes DIMENSIONS 06.04.IB SIZE Max. Max. Allow. Deflect. Fr. Dimensions Aprx. Nominal Work End Pipe Lt_ Bolt/Nut ter, Wg Per Pipe Inches Pres. Load End t No. - Size Each Aciuz PSI° Lbs.* Sep. In. Cplg. In.! Ft. Inches Lbs. kPr N mm Deg. mtu!m mm X V Z i'.g 10§ 800 73,280 0:0:13 0°-40' 2-1 x 6 13.3 17.13 263 31.1 12 § BOO 102,000 0-0.13 -34' 0.12 2- 1 X 6½ 15.63 19.25 2.63 27.8 14 300 46,180 0-0.13 0°-31' O•:1 4-1 x 31A 16.63 19.88 2.88 356 15 300 53.000 0-0:13 O°-29' 0.10 41 X 5½ 17.68 21.63 3.00 48.8 16 300 60,320 0-03 0°-27' 4-1 X 31/2 19.00 22.13 3.00 51.1 300 76,340 0-0.13 0-24 0.08 1 41X3A 21.38 r 24.50 3.13 64.4 300 94,000 0-0.13 0°-22' 0.08 4-1% X 423.63 27.25 3:13 91.? P,20 - 114,000 0-0.13 , 0-19 0.07 .4 300 1 4-1/aX4 25.75 29.50 3.13 92.0 .-. 4.47 250 113,000 0-0.13 , 0-18 0.07 1 6-1/aX4 27.75 31.25 3.13 94.0 ?4 94 fl Couplings 8, 10, 12 (219,1. 273,0, 323,9 mm) sizes available to JIS standards. Refer to Section 06.17 for details. "t@ Refer to notes below. MATERIAL SPECIFICATIONS Housing: Ductile iron conform- tug to ASTM A-395, grade 65- 45-15, and ASTM A-536, grade 65-45-12. Housing Coating: Orange enamel O Optional: Hot dipped galva- nized and others Coupling Gasket: (specify choice)t O Grade "E" EPDM Vic-Plus Gasket System EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to +1101C). Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical ser- vices. UL classified in accor- dance with ANSI/NSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) potable water service. NOT RECOM- MENDED FOR PETROLEUM SERVICES. O Grade "T" nitrile Vic-Plus Gasket System Nitrile (Orange color code). Temperature range -20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified tempera- ture range. Not recom- mended for hot water services over +150°F (+66°C) or for hot dry air over +140°F (+60°C). Services listed are General Ser- vice Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Refer- ence should always be made to the latest Victaulic Gasket Selection Guide for specific gas- ket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat treated car- bon steel, zinc electroplated to ASTM B633, track-head con- forming to physical properties of ASTM A-183 minimum tensile 110,000 PSI (758340 kPa). tSupplemental lubricant is rec- ornmended for services installed at or continuously operating below 0°F (-18°C). O Optional: I\jpe 316 stainless steel, Grade B-8M, Class 2. NOTES * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. f Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 - 31h' (26.7- 101,6 mm); 25% for 4"(114,3 mm) and larger. © Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 06.04-2 STYLES 920 AND 920N rM - ILPCBI SEE vicTAuLic PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-Ta Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent an the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-I in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page B for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°FI-i-82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date__________________________________ www.victaulic.com lid VICTAULIC IS REGISTERED TRADEMARK OF VICTAIJuC COMPANY. © 2007 VICTAUUC COMPANY. ALL RIGHTS RESERVED, PRINTED IN THE USA. REV) 11.02_i (PS CARRION STEEL PIPE - HOLE CUT PRODUCTS 11.02 = STYLES 920 AND 920N DIMENSIONS 4 V ) O ..½(a) 920N 500 1.50 2002.53 l.6l5.352.753.1 50 ' 15 3450 38.1 51 64 41 136 70 15 - I 14 (a) 20N 500 150 1.97 2.53 1,61 5.35 275 3.1 20 3450 38.1 50 64 41 136 70 1.5 - 1 (a) - 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 3450 38.1 47 64 41 136: 70 1.4 920N 500 1.75 2.05 . 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 ............... 3450 52 70 76 41 136 76 1.7 1.5 1½(a)t 0N 500 1.75 2.03 2.75 3.12 1.61 5.35:3.253.6:3.2 401.J9' 3450.44.552 70:7941 13683.1.71.5 4 V '4-Z ---I 2½ i'Sa.(a). NSOOi5O22i2i4 91,82:5.64;2,753,0 65 > 920 3450 . 38.1 : 56 70 - 46 143 70 1.4 - A V 175 .... ,., ................................ I 15(a) 920N 500 1.50 2.18 . 2.74 1.82 5.64 2.75 3.0 V 20 3450 38.1 .55 70 - 461143701.4 - I 1(a) I 920N 500 150 2.05 2.74 1.82 5.64 2.75 2.9 345 ..; 52 7 46,143170 .....................•1. W 1 t (a) 500 1 75 230 3.00 3.25 1.82 629 300 3.5 3.2 32 920N,3450 58 76 83 46160:7611.711.5 1½'t(a) 500 2.00 2.28 3.00 3.25 1,82;6.2613.2513.6 1 3,3 FEMALE THREADED OUTLET 40 920N 3450 . 50.8 58 76 83 46 L. 159 83 1.7 ,j 1.6 ½(a)920i30O1,502.22(2.75 2.256.46 3183.9 75.x 15 2065138,1:56,70l 57(16481 is I Provides a direct branch connection at . ~ (a) 920 300 1.50 2.19 2.75 2.25 6.46 ' 3.18 3.9 any location where a hole can be cut 2065 38.1 .6 .?° , - ...- . ...L. 164 81 JL T.... in the pipe 1(a) 920 300 1.50 . 2.07 2.75 - 2.25 6.45, 3.18 3.8 - 25 ...... ,57 164 ........ 17 A pressure responsive gasket provides ia 20 500 1.75 : 2.30 3.00 . 3.31 , 1.92 6.29 3.00 3.5 3.2 the seal ____.L.. ........ .? ............84 4g:16O76 .1.6 .1.5 1½(a)9201500i2fl0.2.28.3.00331(1,92:629325 3.5 3.3 Request Publication 11.03 for ......3450 ......, ....5876 .......1 .., Mechanical-T cross assemblies ½ (a) 920N 500 1.50 : 2.52 : 3.05 - 2.28 6.15 ' 2.75 3.4 - 80 3450j38.1 64 78: , 581156 1 70]1.6 . Pressure rated up to 500 psi/3450kPa -Y~ (a) 920N 500 . 1.50 2.49 3.05 - 2.28 6.15 2.75 3,4 - on steel pipe; also available for use 20 ............., 3450 38.1 ,3 . ,78 .........?cL.......1.L................ withHDPErine 1(d) 20N 500 150 2.38 3.06 - 2.28 6.15 2.75 3.3 V •' 2 ,J 3450 ' 38.1 ' 61 78 1 58 156 70 1.6 - Sizes from 2 x 1h/50 x 15 mm 11A(a)t)I 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4/200 x 100 mm ......3450 44.5 65 83 90 .•,, 156 ...1.8 18 1 ½ (a) t 20N 500 2.00 2.78 350 3.56 2.28 . 6.15 1 3.25 . 4.1 3.8 40(b): 3450 , 50,8 1 71 . 89 , 90 58 156 83 1.9 1.8 2(a)j20N15002.50 .2.75 3.50 3.56 2.28 6.75 i 3.88 4,9:4.6 50( 3450 63.5:708990.58172199 2.3 2.1 3½'5 "i :5002501 :375:244:672:388 3.8 X so . 920N 3450 , 63,5 1 - - 95 62 . 171 gg - 1.8 IMPORTANT NOTES: . ' ' TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com vIcTAuLIc IS A REGISTERED TRADEMARK or vicTAulic COMPANY. © 2007 VIcTAuLIc COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. ]i.07._2 A t9 REV -J (PS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N DIMENSIONS * Y Z- TABLE CONTINUED FROM PAGE 2 4 ½(a) 20N 500 1.50 3.03 3.56 2.697.017.75:3.7 3450 38.1 77 90 68178 701.8. 4.. .••. 14(a) 500 1.50 3.00 3.56 2.69 7.01 2.75 37 - - 20 920N 3450 38.1 76 90 - 68 178 70 1.8 . -. 1(3) 500 1.50 2.88 3.56 2.69 7.01 . 2.75 3.6 25 920N 3450 38.1 73 90 - 68 178 70 1.8 - GROOVED OUTLET 1/*(a)f 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32 (b) . 3450 44.5 78 96 102 1 68 178 76 1.9 1.8 1½(a)t920N 500 2.00 3.28 4.00:4.00 2.69 7.01;3.254.2i3.9 z 46(b) 3450 50.8 83 ..102.H..°2 68 178 !L tr ___ . 2t.i 50 1 92oN 500 3450 63.5 83 102 102 68 V 214.(a) 500 500 2.75 2.88 4.00 4.00 2.69 7.344.635.8 5.0 65.1 3450 69,9 73 102 .10268186118 2.6 23 7 920500 2.75 4.00 2.69 7.34:4.63 6.4 W 3.. 3450 69.9 t 10268 1861118 12.9 3 (a) t 500 3.50 3.31 . 4.50 4.12 2.69 1 7.73 1 5.12 8.4 6.4 80 920 3450 . 88.9 84 i 114 105 68 1 196 130 3.8 2.9 FEMALE THREADED OUTLET ............................................................................. - ........... .... 1 20 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 .108.0 X 32.I .., 345044.5 :7896 : ..... 2.3 ... 1 h(a) 500 200 328 400 263 764 325 50 Provides a direct branch connection at 40 920N 3450 50.8 83 102 - 67 194 1 83 1 2.3 any location where a hole can be cut 2 (a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 - in the pipe ............67 194 102 1.9 .... 500 2.75 2.88 4.00 4.00 2.63 7,64 4.29 8.0 A pressure responsive gasket provides 6.Immj 9 ..20 ...50 .....?.j 19. ....J....L,!....L ..19... the seal 920 500 3.50 3.31 450 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 - 67 194 124 3.1 1 3.0 Request Publication 11.03 for 5 1½ (a) 5 500 2.00 4,03 . 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies .125 X .920 3450 1, 50.8 102 I ..!! 121 ..80 246 94 2.4 34 2(a).t.1920 500 2.504.0O4,75 4.75 3.16 9.70 4.3818.28.O Pressure rated up to 500 psi/3450 kPa 633 io 121 ..1218024611113.7 3.6 on steel pipe; also available for. use . 2½ (a)t 1 920 500 2.75 3.63 . 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450.69.9. 92 121 121 80 1 246 1 118 3.8 3.6 761mm 920 500 275 - - 475 316 970 463 = 180 Sizes from 2x ½/50x 15 mm . ............ , ..........80 246 119.................3.6 through 8 x 47200 x 100mm . 3 1 920 500 330 3.81 : 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80. 3450 88.9 . 97 127 118 . 80 246 . 135 3.8 4.0 1330 2 920N 500 . 2.50 375 43Q : 3,17 3.00 3.88 8.0 50 3450 63.5 95 114 - 81 203 99 3.6 - 3.19205003.50 3.815.001 3.00;9.465.318.0l 30. 3450 . 88.9 97 127 . - : 75 240 135 , 3.6 - TABLE CONTINUED ON PG. 4 .. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve Cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 30 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV J 11.023 (PS CARBON STEEL PIPE - HOLE CUT PR000CTS 11.02 STYLES 920 AND 920N DIMENSIONS ''-Z---)-j TABLE CONTINUED FROM PAGE 3 . V 1 112 t ON 500 200 3.78:4.50. 3.30 8.23.3.25:7.0 I 1 139.7x.40 92 3450 50.8 96 :114 84 209833.2 2f 500 2.503.75:4.50 .3.308.233.889.0: -- 50 920N3450 63.5 95 114 - 84 209 99 4.1 500 2.75 3.63 4.75 . 3.13 9.85 4.63 B. 76.1 mm 920 3450 69.9 92 . 121 - 80 250 118 4.0 - GROOVED OUTLET 76.1 m 920 500 3.50 4.63 3.16 9.70 5.31 11.0 - 3450 88.9 118 . 80 246 135 5.0 500 3.50 3.81 5.00 4.63 3.16 9.855.38.14.0:14.2 88.9 920:3450 88.9 96.80: i271188O. 2501137 6.4 6.4 6.:1¼Ia. ON50° 1.75.4.43 3.79915 3.25. 4.8 ISO x 92 3450 445 . 112 .._......:..9J 232 83 Li 2.2 V .:11/i(a)t 500 2.004.405.13j5.133.799.153.255451 T 920N 3450 50.8 112 130 •19• . ------ - 1.2.(a)t ON 500 2304.385.13I5.133.799.15!3.88 w 92 6O 5.6 3450 63.5 111 130 1 130 96 232 99 2.7 2.5 2½(a)t 500 2.75 4.015.135.12 3.6910.51:4.6315.3 7.6 65 920 3450 69.9 110 130 130 . 94 267 118 3.8 13.4 FEMALE THREADED OUTLET . so7§3 mm ' . 21 3.69 10.51 .4.63 5.4 920 3450 .....38 500 3.50 4.315.505.13;3.69;1O. 3(a)t 20 51 5.31 9.9 8.4 Provides a direct branch connection at . 80 : 3450 88.9 110 140 130 94 267 135 4.5 3.8 any location where a hole can be cut 4(a)f 920 500 4.50 3.81 j 5.75 5.38 3.69 10.51 6.25 10.1 10.1 the ___ 100. 3450 114.3; 971146137:94267 159 4.6 4.6 in e pipe -. _____.............................................. ........... .....................,...... .............................. ............ 1590 1 920N 500 1.75 4.43 5.13 : - 3.63 : 9.40 3.25 9.0 8.7 A pressure responsive gasket provides .. : ............_...iQ.... !239 83 4.1 the seal 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 jj ...9 9:.L.J12 ..130 . 92 239 83 35 ... .............................. Request Publication 11.03 for . z 920N . 2.50 4.38 5.13 - 3.63 9.40 3.88 8.0 Mechanical-I cross assemblies . 50 ......:• 63.5 Ill 130 .-..............92 .239 99 3.6 7 0 500.2.7514.38:5.50 5.13 3.63 9.40 4.63 9.5(95 Pressure rated up to 500 psi/3450 kPa ...:.:.SPmi 92 3450: 69.9 L, .........°.......! .........................9 ..........1 43 on steel pipe; also available for use 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 1 8.1 14 . .0 with HDPE pipe . . . . 80 .1 3450 - 88.9 110 140130;92 . 1081mm1 920 500 430 - - 538 363 940 612 - 100 4-5 : 3450 Sizes from 2 x ½/50 x 15mm . 114.3 -----..---. through 8x4/200x100mm H.4 920 : 500 4.50 3.81 5.75 - 3.63 9.40 6.25 18.0 100 . .1 3450 114.3 96.80 146 : 92 239 159 8.2 . . . TABLE.CONTINUEO ON PG..5..:.: IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VIcTAULIC IS A REGISTERED TRADEMARK or VICTALILIC COMPANY. 02007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 11.024 x-kaulid REV i PS CARBON STEEL PiPE HOLE CUT PRoUC; 11.02 STYLES 920 AND 920N dimensions GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1050 x 15 mm through 8 x 47200 x 100 mm WINE TABLE CONTINUED FROM PAGE 4 165.1x 1920 00 1.50 3.88 4.56 3.79:9342.758.0. 25 345038.199 116 '96S2377O3.6- 1/4920 500 1.75 4.43513 3.79'9.343.258.4 32 . 3450 44.5 113 130 - 96 237 83 1 3.8 - 1½(a)t.920.500 2004.41 5.13 3.79 9.34 3.25 8.4 40, 3450 50.8112 130 9623783s3.8 2(a)f.920 500 2.50 4.38 5.13 3.799.34:3.888.5 50 3450 63.5111130 96!2375993.g, 21ht 920 5002.75401513 3.63 10.51 4.63 8.6 7.6 65 3450 10 130 - . 92 2671i8 2.9 3.4 761 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 345069.9 110130 13292 2675118s3.9.3.4 3(a)t 920.500.350 4.31 5305.1353.63 10.51:5.3110.28.4 80 3450 88.9 110 140 130 . 92 267 135 4.6 3.8 4 (a) t 920 500 4.50 3.81 5.75 i 5.38 3.63 10.51 6.25 10.5 8.4 100 114 .3 97 146 13792 .3450 ....159 - 4.8 ...3.8 ":8 2 (a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 .200 X .50 1 69.9 138 157 1 159 122 316 114 5.3 5.3 2½(a)t 920 500 275 507 619 619 4.81 1242 4.50 116 11.6 65. , . 3450 69.9 129 157 157 122 316 114 5.3 5.3 mm.1 920 500 2.75 676.11 .25 4.81 12.42 4.56 11.6 59 1 12..... 116 5.3 'I 920 500 3.50 5.31 i 6.50 .6.50 4.81 12.42 1 5.31 1 12.6 11.6 345088.9 .135 --165165 .122316135 1 5.7 53 4(a) t,:. 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100. , 3450 114.3 122 171 162 122 316 159 69 7 * Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 41 Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify'BSPT' clearly on order (b)For 76.1 mm threaded outlet, specify 21W BSPT clearly on order. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVJ ;FS CARBOM STEEL P1FI- - i-tALE CUT ROAUCTS 11.02 ........ -.---.,.-....J.. STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-Ta fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, Values Values for flow of water at +60F/+16°C are shown in the table below. Exaggerated for clarity ½ 1 0.840 2.0 ... 2 1 2.375 . 9.0 10.5 15 21.3 0.6 50 60.3 2.7 3.2 .34 1.050 4.0 2½ •1 2.875 11.0 12.5 20 26.7 - 1.2 73.0 . 3.4 3.8 1 1.315 . 5.0 3 3.500 13.5 . 153 25 33.7 .15 88.9 4.1 4.7 11/4 - 1.660 55 6.0 -41 4.500 20.0 22.0 - 32 .. 42.4 1.7 1.8 1143 6.1 6.7 11h 1.900 7.0 8.0 40 . ... 48.3 i 2.1 2.4 Formulas for C, Values: = Q? C',2 = c FAP Where: Q = Flow (GPM) = Pressure Drop (psi) C, = Flow Coefficient Size Cv Size Cv Size -CV 10 INI 3,110 ON ~15 21.3 j 32 42-4 1 73.0 ~p 1.050 1 26.7 21 1 1.900 3.500 1 60 Ba.9 200 40 48.3 25 33.7 1 www.victaulic.com VICTAULIC Is A REGISTERED TRADEMARK or VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 1] .026 VIC-TAP II HOLE CUTTING TOOL FOR 4- 8°/100 - 200 MM CARBON STEEL PIPE iFS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publi- cation. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 . 2.875-6.625 All 1040 400 400 400 65-150 .1 73.0-168.3 2755 2755 2755 ..21/2-4 2.875 -4300 All DF 300 300 300 65 -100 73.0-114.3 2065 2065 2065 :.21/24 2.875 -4.500 All SF 300 300 300 65-100 73.0-114.3 2065 2065 2065 TTo ...........................................................io 300 300 250 150 168.3 i ..~96 .... 2065 1724 S 6.625 34 0 40 300 300 300 150 168.3 2065 2065 2065 S 8.625 21/2 10.40 400 - .300 219.1 2755 - 8.625 34 10 300 - 250 200 219.1 - 2065 1724 8.625 300 300 200 219.1 3040 2065 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/345OkPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 57125 mm, 67150 mm and 87200 mm diameter pipe. The Style 931 comes with a 21h'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victauIic.com vlcrAuuc IS A REGISTERED TRADEMARK 01 VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE LISA. REV J \ctaUlIc 11.02 7 ro STYLES 920 AND 920N INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 1111111111111111111111111111111111111111 Ill WCAS-6YCLDG For complete contact information, visit www.victaulic.com 11.02 1480 REV UPDATED 4/2007 VICTAULIC IS A REGISTERED TRADEMARK or viclAulIc COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. xk~ aulie 11.O2J3 ®LPCB) [ VNIIPO See Victaulic publication 10.01 for details FireLock0 products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location - Date Approved www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VIcTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.03 PS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 DIMENSIONS to E L-0 Cto to I NO. 001 NO. 003 NO. 002 NO. 005 114 1.660 32 42.4 - 1½ 1.900 40 48.3 - 2 2.375 2.75 50 60.3 70 2½ 2.875 3.00 65 73.0 76 761 mm 3.000 3.00 76.1 - 76 3 3.500 3.38 80 88.9 86 08mm 4.250 4.00 108.0 102 4 4.500 4.00 - 100 114.3 102 - 5 5.563 4.88 125 141.3 - 124 159mm 6.250 530 - 158.8 140 - 6 . 6.625 530 150 168.3 140 8 8.625 6.81 200 - 219.1 173 0.8 0.3 21 0.1 - - .- - - 0.82 0.4 - - - - . - 21 . 0.2 1.7 0.8 2.00 51 1.8 0.8 2.75 70 2.4 1.1 0.88 22 0.6 0.3 3.1 1.4 2.25 57 . 2.2 1.0 3.00 76 3.6 1.6 0.88 22 1.0 03 330 2.25 2.4 1.5 57 1.1 4.0 1.8 250 64 3.1 1.4 338 86 5.3 2.4 0.88 22 1.2 03 5.7 2.6 3.00 76 5.1 23 4.00 102 73 3.4 6.7 3.0 3.00 76 5.6 2.5 4.00 102 8.7 3.9 1.00 25 2.4 1.1 12.6 5.7 : 3.25 . 83 83 3.8 4.88 124 15.7 7.1 1.00 25 4.1 1.9 12.6 5.7 330 89 9.2 4.2 330 140 17.9 8.0 183 8.3 330 1 89 11.7 53 530 140 22.7 i 103 1.00 25 5.9 2.7 253 11.6 4.25 108 20.4 9.3 6.94 176 T 38.7 17.6 1.13 29 12.7 5.8 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.032 REV 0, PS CARBON SI EEL HI-E -- HEE PROTECTION PROOUJS 10.03 FLOW DATA l .. 11/4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 ½ 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 33 50 60.3 1.1 0.5 2.6 2½ 2.875 4.3 2.2 10.8 4.3 - 65 73.0 13 - 0.7 3.3 1.3 761 mm 3.000 4.5 2.3 11.0 43 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 50 80 88.9 15 0.8 4.0 1.5 108 mn-i 4.250 6.4 3.2 153 6.4 108.0 20 - 0.9 4.7 - 2.0 4 4.500 6.8 3.4 16.0 6.8 100 1143 2.1 1.0 4.9 2.1 5 5.563 85 4.2 21.0 83 125 141.3 - 2.6 -13 5.4 2.6 159 mm 6250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 - 2.9 6 6.625 10.0 5.0 25.0 10.0 ISO - 168.3 - -. 3.0 - 13 7.6 - - 3.0 6 8.625 13.0 5.0 33.0 13.0 200 219.1 I 4.0 1.5 10.1 4.0 f The flow data listed is based upon the pressure drop of Schedule 40 pipe www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. A:~i~~ Ulid REVG 10.03 3 GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. II! Il(I llhIII!IIIIIllhII I llII IIIII III WCAS-6QAQS9 For complete contact information, visit www.victaulic.com 10.03 1539 REV 0 UPDATED 3/2008 VICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. @ 2008 VICTAULIc COMPANY. ALL RIGHTS RESERVED. 10.03 Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2' thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 3½ 2/8 400 11 3/4 3/8 8mm or 10mm 31/8 21h 400 11 1 3/8 8mm or 10mm 33A 25A 400 12 11/4 3/8 8mm or 10mm 33/4 2/e 400 13 1112 3/8 8mm or 10mm 37/8 27/a 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57A 4 600 29 31/2 3/8 10mm 73/s 51/4 600 34 4 3/8 10mm 7/s 5 1000 35 5 1/2 12mm 9'/e 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.6599 • FAX: 951.737.0330 'I CUSTOMER SERVICE • 800.786.5266 www.tolco.com Dimensions Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. Rod. Stiffener Size Range —SQureè3/8" thru 7/8 hanger rod Material - Carbon I Function - Secures chaieLtgjianger rod for vertical seismic Approvals - Underwriters LabotoiListed in the USA jJJk Canada (cUL). Included in our Seismic Rtaints catt6 app Finish - Elect9..G1vanized Note - iaitgble in HDG finish or Stainless Steel materials. Order By - Figure number Component of State of California OSH erIJL us LISTED Seismic lRestr yslem Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By Figure number, rod diameter, rod length and finish Fig. 100 — All Thread Rod Full Lengths Size Range - Secures 3/8' thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY. 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FM: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com C®Us LISTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4fl thru 2' pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pnly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • P11: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 Is www.tolco.com Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 We 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* Wt./100 3/8 1Ae 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 rAW Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved c61 Seismic Restraints System US LISTED Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8' rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bot- tom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note -Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 * Max. loads for clamp with set screw in up or down position. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 si CUSTOMER SERVICE • 800.786.5266 www.tolco.com RIY1 Drop-In Anchor Lipped anchor body keeps anchor flush Easy installation Keeps all rods same length tt i Easy inspection Available in carbon steel, 18-8 and 316 stainless steel RL Drop-In Anchor MR Below surface setting for easy patch work t Higher performance potential with deep embedment setting RX-38 Drop-In Anchor iK Optimized (only 3/4" long) for use in -core, pre-cast plank and QI hollow post-tension slabs Lip keeps anchor flush during installation Shallow drilling—fast installation Coil Thread Anchor Quick thread attachment— ideal for 1 sided forming Use coil rod on job .. 2 diameters (1/2' and 3/4') :. Systems aun EN DESCRIPTION/SUGGESTED SPECIFICATIONS Drop-in, Shell-Type Anchors- SPECIFIED FOR ANCHORAGE INTO CONCRETE Drop-In, shell-type anchors feature an internally threaded, all-steel shell with expansion cone insert and flush embedment lip. Anchors are manufactured from plated carbon steel, 18-8 stainless steel and 316 stainless steel. rm Anchors should be installed with carbide tipped hammer drill bits made Internally Threaded Heavy- Duty Anchoring in accordance to ANSI B212.15-1994 specifications. Anchors should be tested to ASTM E488 criteria and listed by ICC (formerly ICBO) and SBCCI. Anchors should also be listed by the following agencies as required by the local building code: UL, FM, City of Los Angeles, Metro-Dade ulti-Set4l DIop-In Anchors County, California State Fire Marshal and Cal Trans. ,mi'Ramset/Red Head" Call our tollIest number BOO-8197890 or visit our web site for the most misers product and teobokal Information atwww.,ams,t-redhead.00m For use with threaded rods or headed bolts (supplied by contractor) MuitiSt II Anchors Pumps and heavy piping are common Meets or exceeds U.S. Government G.S.A. Specification FF-S-325 applications for larger diameter Group VIII, Type 1 Multi-Set Drop-In Anchors. Underwriters Laboratories Factory Mutual ICC Evaluation Service, Inc. - #ER-1372 (formerly ICBO) City of Los Angeles - #RR2748 SBCCI Compliance Report - #9570 Cable tray and strut suspended from concrete ceilings are ideal Multi-Set California State Fire Marshal applications. In post-tension or Cal Trans hollow-core slabs use the RX-38. To set anchor flush with surface: 1 The Multi-Set Anchor is the standard . Drill hole the same diameter as outside diameter of anchor being used to any depth exceeding for pipe-hanging. The RM version has a minimum embedment. Clean hole. retainer lip to keep all anchors flush at the surface, keeping all your threaded Drive anchor flush with surface of concrete. rod the same length. r Expand anchor with setting tool provided. Expander Slots—allow for easy setting f , 'b Anchor is properly expanded when shoulder and superior performance Lè1F.°' of setting tool is flush with top of anchor. Cone Insert—that expands the anchor when driven with setting tool and hammer To set anchor below surface. Drill hole deeper than anchor length. Thread bolt into anchor. Hammer anchor into hole Body—available in zinc-plated steel, 18-8 stainless steel, and 316 stainless steel until bolt head is at desired depth. Remove bolt and set anchor with setting tool. Easy Depth Inspection—keeps threaded rod drop lengths consistent Retainer Lip—to keep anchor flush PART NUMBER RTX-138 with surface For use with RX-38 only. 'M..ã...fl- PART NUMBER RT-138 1 setting tool per master carton— (See page 75 for part numbers.) ,rp,Ramset/Red Head Call our Dii free number $00-899-71190 or visit our web rite for the most current product and technical information at www.namret-r,dtread.cum USER APPLICATION I BASE CORROSION DROP-IN PART SETTING BOLT SIZE- - DRILL BIT THREAD EMBEDMENT QTY/WT QTY/WT TYPE MATERIAL RESISTANCE ANCHOR NUMBER TOOL THREADS SIZE DEPTH MIN. HOLE PER BOX PER LEVEL TYPE PART PER INCH In. (mm) In. (mm) DEPTH lbs. MASTER (TN NUMBER In. (mm) Ills. HVAC/FireSprinkler Poured in place low RM RM-14 RM-38 91-114 91-138 1/4-20 3/8-16 3/8 (9.5) 1/2 (12.7) 3/8 (9.5) 1/2 (122) 1 (214) 1-5/8 (41.3) 100/ 2.6 50/ 3.4 1000/ 28 500/36 concrete! RM-12 91-112 1/2 -13 5/8 (15.9) 3/4 (19.1) 2 (50.8) 50/ 5.8 400/ 49 - lightweight RM-58 81-158 5/8 -11 7/8 (22.2) 1 (214) 2-1/2(63.5) 25/ 7.8 125/ 41 - fill deck RM-34 91-134 3/4'-10 1 (25.4) 1-1/4 (31.8) 3-3/16 (81.0) 25/ 11.9 100/49 Hollow-core pie-cast Low RX RX-38 RTX-138 3/8 -16 1/2 (12.7) 1/2 (12.7) 3/4 (19.1) 100/ 33 1000/ 36 or Post- tension Solid Medium SRM SRM-14 91-114 1/4-20 3/8 (95) 3/8 (9.5) 1 (25.4) 100/ 2.7 1080/28 concrete 18-8 5,5. SRM-38 91-138 3/8 -16 1/2 (12.7) 1/2 (12.7) 1-5/8(413) 50/ 3.4 500/ 36 5RM-12 91-112 1/2-13 5/8 (15.9) 3/4 (19.1) 2 (50.8) 50/ 6.0 400/50 SRM-58 91-158 5/8-11 7/8 (22.2) 1 (25.4) 2-1/2 (63.5) 25/ 18.0 125/42 SRM-34 91-134 3/4-10 1 (25.4) 1-1/4 (31.8) 3-3/16 (81.0) 25/ 12.0 100/50 Solid High SSRM SSRM-38 91-138 3/8-16 1/2 (12.7) 1/2 (12.7) 1-5/8 (41.3) 50/ 3.4 500/36 concrete 3165.5, SSRM-12 RT-112 1/2'-13 5/8 (119) 3/4 (19,1) 2 (50.8) 50/ 6.0 400/ 50 Concrete Contractor, Solid Low CL-Coil (1-12 91-112 1/2"-6 5/8 (15.9) 3/4 (19.1) 2 (50.8) 50/ 53 400/ 47 General Contractor, Highway concrete Threaded CL-34 91-134 3/4'-43 1 (214) 1-1/4 (31.8) 3-3/16 (81.0) 25/11.9 100/49 Concrete Cutting! Sawing Contractor/Misc. Metal Solid concrete Low RL (w/o lip) RL-14 RL-38 RL-12 91-58 91-114 91-138 RT-112 91-158 1/4'-20 3/8 -16 1/2-13 3/8 (93) 1/2 (12.7) 5/8 (15.9) 3/8 (9.5) 1/2 (12.7) 3/4 (19.1) 1 (25.4) 1-5/8 (41.3) 2 (50.8) 100/ 2.6 50/ 3.4 50/ 5.8 1000/ 28 500/ 36 400/ 49 '' I 5/8 -11 7/8 (22.2) 1 (25.4) 2-112 (63.5) 25/ 7.8 125/ 41 RL34 91134 3/4 10 1 (254) 11/4 (318) 33/16 (810) 25/119 100/49 r * 1 setting tool per master carton. miRamset/Red Head' call our toll tee number 000-899-7090 orviult our web sire for the most consent product and technical informatlor, at www.rumset-nedhead.com I- I I- tABE:WR f.C25.1Tj Ultimate Shear and Tension Values (Lbs/kN) in Concrete* BOLT OIL in. (mm) ANCHOR MIN. EMBEDMENT WA. DEPTH In. (MM) In. (Min) ANCHOR TYPE TENSION Lbs. kN) SHEAR Lbs. (kN) ____________________ f'c = 2000 psi (13.8MPa) f'c = 4000 PSI (27.6MPa) f'c = 6000 P51 (41.4MPa) f'c ~2000 PSI (13.8MPa) 1/4 (6.4) 3/8 (9.5) 1 (25.4) RM, DL or CL-Carbon or SRM-18-8 5.5. or 559M-3165.5. 1,680 (7.5) 2,360 (10.5) 2,980 (13.3) 1,080 . (4.8) 3/8 (9.5) 1/2 (12.7) 1 1-5/8 (41.3) 2,980 (13.3) 3,800 (16,9) 6,240 (27.8) 3,160 (14.1) 1/2 (12.7) 5/8 (15,9) 2 (50.8) 3,300 (14.7) 5,840 (26.0) 8,300 (36.9) 4,580 (20.4) 5/8 (15.9) 7/8 (22.2) 2-1/2 (633) 5,500 (24.5) 8,640 (38.4) 11,020 (49.0) 7,440 (33.1) 3/4 (19.1) 1 (25.4) 3-3/16 (81.0) 8,280 (36.8) 9,480 (42.7) 12,260 (543) 10,480 (46.6) * Allowable values are based upon a4 Sal safety factor. Divide by for allowable load values. - Ultimate Shear and Tension Values (Lbs/kN) in 'IoJiMIEM Lightweight Concrete* 1 In. 1DI ) BOLT ANCHOR MINIMUM ANCHOR LIGHTWEIGHT CONCRETE LOWER FLUTE OF STEEL DECKWITH A. WA. EMBEDMENT TYPE f'c=3000P51(20.7MPa) LIGHTWEl6HTCONCRETEFILL (mm In.(mm) DEPTH _________________ _______________ f'c =3000 PSI (20.7MPa) In. (MM) TENSION SHEAR TENSION SHEAR Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 3/8 (93) 1/2 (12.7) 1-5/8 (39.7) 3,860 (17.2) 4,420 (19.6) 3,340 (14.9) 4,420 (19,6) 1/2 (12.7) 5/8 (15.9) 2 (50.8) or CL-Carbon or 518-85or 4,080 (18.1) 5,640 (25.1) 3,200 (14.2) 4,940 (22.0) 5/8 (15.9) 7/8 (22.2) 2-1/2 (633) 6,280 (27.9) 10,440 (46.4) 5,960 (265) 5,840 (26.0) 3/4 (19.1) 1 (25.4) 1 3-3/16 (81.0) 11,000 (48.9) 1 15,780 (70.2) 8,180 (36.4) 9,120 (40.6) Allowable values are based upon a4tol safety factor. Divide by for allowable load values. (ómbned Shear and Tension Loading-for Multi-Set Anchors Allowable loads for anchors subjected to combined shear and tension forces are determined by the following equation: (Ps/Pt)oa+ (V/vt)va :51 Ps = Applied tension load Vs = Applied shear load Pt =Allowable tension load Vt =Allowable shear load ,T7RamSetIRed Head (all our loll free number 800-899-7850 or visit our web site for the most meteor product used technical information atwww,ramnet•redhead.tom t Reconnended Spacing and dge Distance Requirements* 7 .. D(1A..) 7ANCHOR EMBEDMENT ANCHOR EDGEDISTANCE MIN.EDGE SPACING MIN.ALLOWABLE DEPTH TYPE REQUIREDTO DISTANCEATWHICH REQUIREDTO SPACING In. (mm) OBTAIN MAX. LOAD FACTOR APPLIED OBTAIN MAX. BETWEEN ANCHORS WORKING LOAD =.80 FOR TENSION WORKING LOAD LOAD FACTOR APPLIED In. (mm) =30 FOR SHEAR In. (mm) =80 FOR TENSION In. (mm) =.ss FOR SHEAR In. (mm) 1/4 (6.4) 3/8 (9.5) 1 (25.4) RM, RI 1-3/4 (44.5) 7/8 (22.2) 3-1/2 (88.9) 1-3/4 (44.5) 3/8 (9.5) 1/2 (12.7) 1-5/8 (413) 2-1/8 (73.0) or Cl-Carbon 1-7/16 (36.5) 5-11/16 (144.5) 2-7/8 (73.0) 1/2 (12.7) 5/8 (15.9) 2 (50.8) or 3-1/2 (08.9) 1-3/4 44.5) 7 (177.8) 3-1/2 (88.9) SRM-18-8 S.S. or 5/8 (15.9) 7/8 (22.2) 2-1/2 (63.5) SSRM-3165.S. 4-3/8 (111.1) 2-3/16 (55.6) 8-3/4 (222.3) 4-3/8 (111.1) 3/4 (19.1) 1 (25.4) 3-3/16 (81.0) 5-5/8 (142.9) 2-13/16 (71.4) 11-3/16 (284.2) 5-5/8 (142.9) Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Uncut interpolation maybe used For intermediuse5pnclng and edge distances Ultimate Shear and Tension Values (Lbs/kN) for RX-38 a a a a (314"Embedment)* SIZE ANCHOR EMBEDMENT 4000PSI (27.6 Pa) CONCRETE HOLLOW CORE In. (mm) DIA. In. (mm) TENSION SHEAR TENSION SHEAR In. (mm) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 3/8 (9.5) 1/2 (12.7) 3/4 (19.1) 1,987 (8.8) 2,903 (12.9) 1,908 (8.5) 2,525 (11.2) The tabulated values are for RX-38anchors installed at minimum of 12 diameters on center and minimum edge distance of6dlameters 1sr100 percent anchor efficiency. Spacing and edge distance maybe reduced to 6diamotnss spacing and 3 diameter edge distance provided the values are reduced 50 percent. Linear interpolation maybe used for Intermediate spacings and edge margins. Allowable values are based upon a 4tol safety factor. Divide by 4 for allowable load values. 1' Anchoring Overhead in 3000 PSI 20 GOD cok s DID In MUM MEM Lightweight Concrete On Metal Deck lower Flute Upper Flute ANCHOR DRILL HOLE EMBEDMENT 3000PSI (20.7 MPa) CONCRETE DIAMETER In. (mm) ULTIMATE TENSION LOAD ALLOWABLE WORKING LOAD In. (mm) the. (kN) Lbs. (kN) RX-38 Drop-In 1/2 (12.7) 3/4 (19.1) Upper flute 1,410 (63) 353 (1.6) lower Flute 1,206 (5.4) 301 (13) Allowable values are based upon a 4 tat safety factor. Divide by 4 for allowable load values. rnwRamset/Red Head' Call our toil her number 850-899-7890 or visit oar web sire for the most current product and technical informarlon ntwww.ramnet-rrrdhnnd.rrrm Fig. 4 - Standard Pipe Clamp Component of State of LISTED California OSHPD Approved c Fig. 4F - Standard Pipe Clamp Felt Lined Seismic Restraints System Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range - (Fig. 4) Size 1/2" thru 30" pipe. El Size Range - (Fig. 4F) Size 1/2" thru 21h" copper tubing Material - Carbon Steel Function Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye Rod.) Also recommended for attachment of sway bracing up to 3/2" pipe size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration and/or prevent electrolysis. Approvals - Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 3/4" - 8", and approved by Factory Mutual Engineering, 3/4" - 8". Federal Specification WW-H-171E, Type 4, 1½" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- Fig. 4 ing and placement information relating to OSHPD projects, please refer - to the TOLCO Seismic Restraint Systems Guidelines. 1 Note —When the Fig. 4 is used as a sway brace, to ensure perfor- mance, the UL Listing requires that it must be used with other TOLCOTm brace products. Maximum Temperature - 750°F ---. / ,• Finish —Plain '-.. Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By By - Figure number, pipe size and finish. Fig. 4F Order Note —When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Fig. 4PVC Dimensions 'Weights Pipe Max. Design Load Lbs. Size A B C D For Service Temp. Approx. Bolt Size 650° 750°F Wt./100 1/2 37/is 1/4 1½ 1½ 5/16 500 445 29 3/4 3/t G 1/4 1¼ 11/4 5/16 500 445 31 1 39/16 1/4 11/4 1/16 5/16 500 445 35 11/4 446 1/2 1m lAs 5/16 500 445 40 1½ 4/is 5/16 1% 17/8 5/16 800 715 42 2* 5V16 1/2 2 21/4 3/8 1040 930 93 21h° 67A 9/16 2½ 2V4 1/2 1040 930 126 3* 7 5/8 2Y4 31Ae 1/2 1040 930 141 316 7A 3/8 3½ 33/h 1/2 1040 930 154 4 816 5/8 3j16 3Wis 1/2 1040 930 229 5 9Y4 3/4 37% 4Ye 5/8 1040 930 261 6 11% 3/4 474 51A 3/4 1615 1440 537 8 13A6 1 5% 6 3/4 1615 1440 625 10 161h 1 71/4 71/4 7/8 2490 2220 1378 12 1816 1 81/4 8¼ 7/8 2490 2220 1574 14 20 1½ 9 9 7/8 2490 2220 2103 16 23 1½ 101/4 10¼ 7/8 2490 2220 2314 18 25½ 1¼ 11½ 11½ 1 3060 2730 3276 20 28 1 y 1216 1216 1¼ 3060 2730 3863 24 331h 1% 15¼ 151/4 11/4 3060 2730 5222 30 417/6 2 19 19 1N 3500 3360 10511 '%__ *Meets UL 203A requirements for attachment of sway bracing. Horizontal design load for 1/2-7' - 380#, 21/2" - 395#, 3"- 435#, 31/2 - 540/f OFFICEIMANUFACTURING FACILITY . 1375 SAMPSON AVE. CORONA, CA 92879 'PH: 951.737.5599. FAX: 951.737.0330 I CUSTOMER SERVICE . 800.786.5266 www.tolcl3.com Maximum Design Load 1" thru 4" pipe size —2015 lbs. 6" size - 1265 lbs. L.clLIcU LIIQ'.., I@ IS LISTED Component of State of California OSHPD Approved Seismic Restraints System Fig. 1000 -"Fast Clamp" Sway Brace Attachment Size Range - Pipe size to be braced: 1" thru 6' Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 IPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a TOLCOTM Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation —The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete brac- ing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is rec- ommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. TOLCOO brand bracing components are desgined to be compatible ONLY with other TOLCOO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY ' 1375 SAMPSON AVE. CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.]3].0330 fm CUSTOMER SERVICE • 800.786.5266 wwwtolco.com Fig. 980 - Universal Swivel Sway Brace Attachment IOU, "I'll Size Range - One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural Component of Slate of California OSHPD Approved steel up to 1/4' thick. Seismic Restraints System Material - Carbon Steel Function - Multi-functional attachment to structure or braced pipe fitting. Features -This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation - The Fig.980 is the structural or transitional ___7 attachment component of a longitudinal or lateral sway brace B assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note —The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000 , Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish — Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish. PATENT #6,273,372 C 1\ Dimensions 'Weights Max. Design Approx. A B H Load Lbs. Wt./100 14 5% 1½ 17/32 2765 132 * Available with hole sizes to accommodate up to 3/4 fastener. Consult factory. Lateral Brace TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NiBCO does NI warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY . 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330 10 CUSTOMER SERVICE • 800.786.5266 www.tolco.com c® )JS LISTED Component of State of California OSHPD Approved Seismic Restraints System Fig. 800 - Adjustable Sway Brace Attachment to Steel Size Range - 4" thru 18" beam width Material - Carbon Steel Function - Seismic brace attachment to steel. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure connection to steel where drilling and/or welding of brace connection could present structural issues. Installation Instructions - The Fig. 800 is the structural attachment com- ponent of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, bracing pipe" and a TOLCO "braced pipe" attachment to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 800 on the steel beam, tighten the cone point set bolts on flange until bolt heads break off. Tighten hex head bolts into clamp body until lock washers are fully flat. Attach other TOLCO tran- sitional attachment fitting, Fig. 909, 910, 980 or 986. Transitional fitting attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, type number and size number. SHOWN WtTH FIG...98 , 0 BRACE FITTING TO PIPE BRA E (ACROSS BEAM) Dimensions • Weights Max. Design Loads/Lbs. (cliLus) *Max. Design Loads/Lbs. (FM) Fits Beam Along Across Along Across Size Range (In.) Beam Beam Beam Beam 1 4-6 1265 2015 2800 2800 2 6-8 1265 2015 2800 2800 3 8-10 1265 2015 2800 2800 4 10-12 1265 2015 2800 2800 5 12-14 1265 2015 2800 2800 6 14-16 1265 2015 2800 2800 7 16-18 1265 2015 2800 2800 Dimensions • Weights SHOWN WITH FIG 980 Max. Design Loads/Lbs. (cULus) *Max. Design Loads/Lbs. (FM) BRACE FITTING TO Flange Thickness Along Across Along Across PIPE CE Type Max. (In.) Beam Beam Beam Beam (ALONG BEAM) . 1 3/4 1265 2015 2800 2800 2 11/4 1265 2015 2800 2800 * Load shown is allowable with brace installed, between 30° - 90°. No reduction of load based on brace angle is required. TOLGOO brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall i,.4QI be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com