Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS090098; Permit4/4/25, 11:17 AM AS090098 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5781 VAN ALLEN WY Permit Type: SPRINK Parcel No: 2121304400 Lot #: 0 Reference No.: Permit No: AS090098 Status: ISSUED Applied 8/25/2009 Approved: 8/25/2009 Issued: 8/25/2009 PC #: Inspector: Project Title: LIFE TECHNOLOGIES T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON POWAY CA 858-513-4949 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 QUICK RESPONSE GLi6B AUTOMATICSPRINKLERS MM MIR wilipm IE' ___ w SERIES FIRE SPRINKLER CORPORATION RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element.. This provides sprinkler operation approximately six times faster than ordinary sprinklers.. While the Quick Response Sprinkler provides an aesthetically pleasing ap- pearance, it can be installed wherever standard spray sprinklers äifidbUtöffëistheadditinal safetyto life,. Quick Response Sprinklers should be used advisedly and underthe direction of approving authorities having jurisdiction.. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The use of the 4 1/2" diameter, recessed escutcheon allows for 1" of clearance around the sprinkler body. Which meets the IBC requirements for use in seismic areas C, D & E. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA a See reverse side for Approvals and Specifications. a Temperature Ratings - 135°F (570C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). a Water Working Pressure Rating - 175 psi (12 Bars).. Factory tested hydrostatically to 500 psi (34 Bars). a Maximum low temperature glass bulb rating is -67°F (-55°0). QUICK RESPONSE RECESSED PENDENT *• QUICK RESPONSE RECESSED PENDNT WITH OPTIONAL IBC SEISMIC RECESSED ESCUTCHEON a Frame - bronze a Deflector - brass o Screw - brass QUICK RESPONSE a Bulb seat - copper • Spring - nickel alloy a Seal - teflon RECESSED a Bulb - glass with alcohol based solution, 3mm size.. HORIZONTAL SIDEWALL Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATINGICLASSIFICAT1ON and COLOR CODING CLASSIFICATION TEMPERATURES CEILING TEMPERATURE ORDINARY L .i. 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 JANUARY 2009 A-24 BULLETIN GL2801, REV. #6 PENDENT WITH OPTIONAL IBC SEISMIC RECESSED ESCUTCHEON QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 112" NPT 2 1/4' (5.7 cm) Factory Bronze 42 (59 metric) 1/2" NPT 2 114" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 7,8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 8.1........................(i.16metñc). .... .....3/4°NPT...... 2.7116".(62cm). Lead Coated NOTE: METRIC CONVERSIONS ARE APPROXIMATE HORIZONTAL SIDEWALL IS 2 9116'. 2FINISHES AVAILABLE ON SPECIAL ORDER. 3C-UL LISTED CORROSION RESISTANT - POLYESTER MUST BE SPECIFIED ON ORDER APPROVALS STYLE SIN MODEL K FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C 286°F 141°C cULus FM LPC CE NYC -DOB MEAIOI-92.E GL2801 28 X X X X X X - - - X 0L4201 42 X X X X X X - - - X PENDENT GL5601 56 x x x x x x x x x x RECESSED GL8101 7.8" X X X X X X X - - X 0L8106 8.1 X X X X X X x x x x I C3L2826 2.8 X X X x X X .- - - X HORIZONTAL I GL4226 42 X X X X X X - - - X SIDEWALL I RECESSED§ GL5626 5.6 X X X X X X - - - X GL8127 8.1 X X X I X X X - - - - § HORIZONTAL SIDEWALL CULUs LISTED FOR DEFLECTOR 4" TO 1 Z BELOW THE CEILING t5 6K ORIFICE 7 81< ORIFICE AND 8 1 K ORIFICE LISTED FOR ALL HAZARDS. *78KX1/2NPT CROSS SECTIONS **286F cULus LISTED ONLY. t 112" RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS. 2 luj,r u—, I ° "° I ORDERING INFORMATION I I "° I I,, RENER - -REM0 SPECIFY Quantity Model Number . Style Orifice • Thread Sizes Temperature - • Finishes desired __ / • Quantity - Recessed Wrenches - PIN 325391 (1/2); 1.4ek 'rn PIN 325401, Rev. F (L.0.) I S/ MA -i • Quantity - Protective Caps - P/N 327109-CAP PENDENT (Friction Fit Recessed) cC, GLOBE® PRODUCT WARRANTY 10 1'r RCTPJCZ _ _ HORIZONTAL FIRE SPRINKLER CORPORATION SIDEWALL Globe agrees to repair or replace any of its own manufactured products found to be defective In material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price ListTerrns and Conditions of Sale (OurPrice List).. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 1-800-248-0278 www.g1obesprinkIer.com JANUARY 2009 PRINTEDU.S.A. BULLETIN GL2801, REV. #6