HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS100039; PermitApplicant: Owner: 626-336-0043 MIKE L. HUANTE JR. 16035 OLD VALLEY RD LA PUENTE, CA GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA 4/4/25, 11:24 AM AS 100039 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS100039 Job Address: 5781 VAN ALLEN WY Permit Type: SPRINK Parcel No: 2121304400 Lot #: 0 Status: ISSUED Applied 3/31/2010 Approved: 3/31/2010 Reference No.: Issued: 3/31/2010 PC #: Inspector: Project Title: LIFE TECHNOLOGY TWO FIRE SPRINKLER INSPECTIONS @ $65/00 Fees ($) Add'IFees($) Total ($) 130 Balance 130 0 about:blank 1/1 HYDRAULIC CALCULATIONS FOR Life Technology 5781 Van Allen Way Carlsbad, CA. DATE: 3-24-2010 FILE NO: life -DESIGN DATA- (Office) OCCUPANCY CLASSIFICATION: Light Hazard DENSITY: 0.10 gpm/sq. ft. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 20' x 20' MINIMUM FLOW PER SPRINKLER: 40 gpm NUMBER OF SPRINKLERS CALCULATED: 10 TOTAL SPRINKLER WATER FLOW REQUIRED: 407.9 gpm TOTAL WATER REQUIRED (including hose): 507.9 gpm FLOW AND PRESSURE (@ BOR) : 507.9 gpm @ 57.6 psi SPRINKLER ORIFICE SIZE: 3/4" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) BOR 90.0 89.0 1989.0 89.9 507.9 57.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 507.9 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 407.9 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 35.0 - - - - 35.8 - - - 2 36.0 - - - - 34.7 - - - 3 36.0 K= 7.35 31.6 41.3 4 36.0 K= 7.35 31.3 41.1 5 36.0 K= 7.35 31.3 41.1 6 36.0 - - - - 32.9 - - - 7 35.0 - - - - 33.6 8 35.0 - - - - 35.8 9 36.0 - - - - 34.5 - - - 10 36.0 K= 7.35 30.1 40.3 11 36.0 K= 7.35 29.6 40.0 12 36.0 K= 7.35 29.6 40.0 12A 36.0 K= 7.35 29.8 40.1 13 36.0 - - - - 32.6 - - - 14 35.0 - - - - 33.6 - - - 15 35.0 - - - - 35.9 - - - 16 36.0 - - - - 34.8 - - - 17 36.0 K= 7.35 31.7 41.4 18 36.0 K= 7.35 31.4 41.2 19 36.0 K= 7.35 31.5 41.2 20 36.0 - - - - 32.9 - - - 21 35.0 - - - - 33.6 - - - 22 35.0 - - - - 36.0 - - - 23 36.0 - - - - 35.4 - - - 24 36.0 - - - - 33.3 - - - 25 35.0 - - - - 33.7 - - - 26 35.0 - - - - 36.2 - - - 27 36.0 - - - - 34.8 - - - 28 36.0 - - - - 34.3 - - - 29 35.0 - - - - 33.8 - - - 30 35.0 - - - - 36.5 - - - 31 36.0 - - - - 35.9 - - - 32 36.0 - - - - 33.5 - - - 33 35.0 - - - - 33.8 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) A 35.0 - - - - 41.2 - - - TOR 35.0 - - - - 42.0 BOR 0.0 SOURCE 57.6 407.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 78.3 2.067 PL 1.00 PF 0.7 1 35.0 0.0 35.8 0.0 7.5 120 FTG T RE -0.4 2 36.0 0.0 34.7 0.0 0.060 TL 11.00 PV Pipe: 2 78.3 2.067 PL 41.00 PF 3.0 2 36.0 0.0 34.7 0.0 7.5 120 FTG T FE 0.0 3 36.0 7.3 31.6 41.3 0.060 TL 51.00 PV Pipe: 3 37.0 2.067 PL 20.00 PF 0.3 3 36.0 7.3 31.6 41.3 3.5 120 FTG ---- PE 0.0 4 36.0 7.3 31.3 41.1 0.015 TL 20.00 PV Pipe: 4 -4.2 2.067 FL 20.00 PF 0.0 4 36.0 7.3 31.3 41.1 0.4 120 FTG ---- PE 0.0 5 36.0 7.3 31.3 41.1 0.000 TL 20.00 PV Pipe: 5 -45.3 2.067 PL 63.00 PP 1.6 5 36.0 7.3 31.3 41.1 4.3 120 FTG T PE 0.0 6 36.0 0.0 32.9 0.0 0.022 TL 73.00 PV Pipe: 6 -45.3 2.067 PL 1.00 PF 0.2 6 36.0 0.0 32.9 0.0 4.3 120 FTG T PE 0.4 7 35.0 0.0 33.6 0.0 0.022 TL 11.00 PV Pipe: 7 78.3 4.260 FL 10.50 PF 0.0 8 35.0 0.0 35.8 0.0 1.8 120 FTG ---- FE 0.0 1 35.0 0.0 35.8 0.0 0.002 TL 10.50 PV Pipe: 8 87.3 2.067 PL 1.00 PF 0.8 8 35.0 0.0 35.8 0.0 8.3 120 FTG T FE -0.4 9 36.0 0.0 34.5 0.0 0.073 TL 11.00 PV Pipe: 9 87.3 2.067 FL 51.00 PF 4.5 9 36.0 0.0 34.5 0.0 8.3 120 FTG T PE 0.0 10 36.0 7.3 30.1 40.3 0.073 TL 61.00 PV Pipe: 10 47.0 2.067 FL 20.00 PF 0.5 10 36.0 7.3 30.1 40.3 4.5 120 FTG ---- FE 0.0 11 36.0 7.3 29.6 40.0 0.023 TL 20.00 PV Pipe: 11 6.9 2.067 FL 11.00 PP 0.0 11 36.0 7.3 29.6 40.0 0.7 120 FTG ---- FE 0.0 12 36.0 7.3 29.6 40.0 0.001 TL 11.00 PV Pipe: hA -33.1 2.067 FL 14.00 PF 0.2 12 36.0 7.3 29.6 40.0 3.2 120 FTG ---- FE 0.0 12A 36.0 7.3 29.8 40.1 0.012 TL 14.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 -73.2 2.067 PL 43.00 PF 2.8 12A 36.0 7.3 29.8 40.1 7.0 120 FTG T FE 0.0 13 36.0 0.0 32.6 0.0 0.053 TL 53.00 PV Pipe: 13 -73.2 2.067 PL 1.00 PF 0.6 13 36.0 0.0 32.6 0.0 7.0 120 FTG T PE 0.4 14 35.0 0.0 33.6 0.0 0.053 TL 11.00 PV Pipe: 14 45.3 4.260 FL 10.50 PF 0.0 14 35.0 0.0 33.6 0.0 1.0 120 FTG ---- FE 0.0 7 35.0 0.0 33.6 0.0 0.001 TL 10.50 PV Pipe: 15 165.6 4.260 FL 10.50 PF 0.1 15 35.0 0.0 35.9 0.0 3.7 120 FTG ---- PE 0.0 8 35.0 0.0 35.8 0.0 0.007 TL 10.50 PV Pipe: 16 72.8 2.067 PL 1.00 PF 0.6 15 35.0 0.0 35.9 0.0 7.0 120 FTG T PE -0.4 16 36.0 0.0 34.8 0.0 0.052 TL 11.00 PV Pipe: 17 72.8 2.067 PL 51.00 PF 3.2 16 36.0 0.0 34.8 0.0 7.0 120 FTG T PE 0.0 17 36.0 7.3 31.7 41.4 0.052 TL 61.00 PV Pipe: 18 31.5 2.067 FL 20.00 PF 0.2 17 36.0 7.3 31.7 41.4 3.0 120 FTG ---- PE 0.0 18 36.0 7.3 31.4 41.2 0.011 TL 20.00 PV Pipe: 19 -9.8 2.067 PL 25.00 PF 0.0 18 36.0 7.3 31.4 41.2 0.9 120 FTG ---- FE 0.0 19 36.0 7.3 31.5 41.2 0.001 TL 25.00 PV Pipe: 20 -51.0 2.067 PL 43.00 PF 1.4 19 36.0 7.3 31.5 41.2 4.9 120 FTG T PE 0.0 20 36.0 0.0 32.9 0.0 0.027 TL 53.00 PV Pipe: 21 -51.0 2.067 FL 1.00 PF 0.3 20 36.0 0.0 32.9 0.0 4.9 120 FTG T PE 0.4 21 35.0 0.0 33.6 0.0 0.027 TL 11.00 PV Pipe: 22 118.5 4.260 PL 10.50 PF 0.0 21 35.0 0.0 33.6 0.0 2.7 120 FTG ---- FE 0.0 14 35.0 0.0 33.6 0.0 0.004 TL 10.50 PV Pipe: 23 238.4 4.260 FL 10.50 PF 0.1 22 35.0 0.0 36.0 0.0 5.4 120 FTG ---- FE 0.0 15 35.0 0.0 35.9 0.0 0.014 TL 10.50 FV Pipe: 24 35.2 2.067 FL 1.00 PP 0.1 22 35.0 0.0 36.0 0.0 3.4 120 FTG T FE -0.4 23 36.0 0.0 35.4 0.0 0.014 TL 11.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 35.2 2.067 PL 136.00 PF 2.1 23 36.0 0.0 35.4 0.0 3.4 120 FTG 2T PE 0.0 24 36.0 0.0 33.3 0.0 0.014 TL 156.00 PV Pipe: 26 35.2 2.067 PL 1.00 PF 0.0 24 36.0 0.0 33.3 0.0 3.4 120 FTG ---- PE 0.4 25 35.0 0.0 33.7 0.0 0.014 TL 1.00 PV Pipe: 27 169.5 4.260 PL 10.50 PF 0.1 25 35.0 0.0 33.7 0.0 3.8 120 FTG ---- PE 0.0 21 35.0 0.0 33.6 0.0 0.007 TL 10.50 PV Pipe: 28 273.6 4.260 PL 10.50 PF 0.2 26 35.0 0.0 36.2 0.0 6.2 120 FTG ---- PE 0.0 22 35.0 0.0 36.0 0.0 0.018 TL 10.50 PV Pipe: 29 96.6 2.067 PL 1.00 PF 1.0 26 35.0 0.0 36.2 0.0 9.2 120 FTG T PE -0.4 27 36.0 0.0 34.8 0.0 0.088 TL 11.00 PV 0'' Pipe: 30 96.6 360 PL 136.00 PF 0.5 27 36.0 0.0 34.8 0.0 2.2 120 FTG 2T PE 0.0 28 36.0 0.0 34.3 0.0 0.003 TL 188.00 PV Pipe: 31 96.6 2.067 PL 1.00 PF 1.0 28 36.0 0.0 34.3 0.0 9.2 120 FTG T PE 0.4 29 35.0 0.0 33.8 0.0 0.088 TL 11.00 PV Pipe: 32 134.2 4.260 PL 10.50 PF 0.1 29 35.0 0.0 33.8 0.0 3.0 120 FTG ---- PE 0.0 25 35.0 0.0 33.7 0.0 0.005 TL 10.50 PV Pipe: 33 370.2 4.260 PL 10.50 PF 0.3 30 35.0 0.0 36.5 0.0 8.3 120 FTG ---- PE 0.0 26 35.0 0.0 36.2 0.0 0.031 TL 10.50 PV Pipe: 34 37.7 2.067 PL 1.00 PF 0.2 30 35.0 0.0 36.5 0.0 3.6 120 FTG T PE -0.4 31 36.0 0.0 35.9 0.0 0.015 TL 11.00 PV Pipe: 35 37.7 2.067 PL 136.00 PF 2.4 31 36.0 0.0 35.9 0.0 3.6 120 FTG 2T PE 0.0 32 36.0 0.0 33.5 0.0 0.015 TL 156.00 PV Pipe: 36 37.7 2.067 PL 1.00 PF 0.2 32 36.0 0.0 33.5 0.0 3.6 120 FTG T PE 0.4 33 35.0 0.0 33.8 0.0 0.015 TL 11.00 PV Pipe: 37 37.7 4.260 PL 10.50 PF 0.0 33 35.0 0.0 33.8 0.0 0.8 120 FTG ---- PE 0.0 29 35.0 0.0 33.8 0.0 0.000 TL 10.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 38 -407.8 4.260 PL 126.00 PF 4.7 30 35.0 0.0 36.5 0.0 9.2 120 FTG ---- RE 0.0 A 35.0 0.0 41.2 0.0 0.037 TL 126.00 PV Pipe: 39 -407.8 6.357 PL 110.00 PF 0.8 A 35.0 0.0 41.2 0.0 4.1 120 FTG 2E PE 0.0 TOR 35.0 0.0 42.0 0.0 0.005 TL 146.00 PV Pipe: 40 -407.9 6.357 PL 35.00 PF 0.4 TOR 35.0 0.0 42.0 0.0 4.1 120 FTG BA PE 15.2 BOR 0.0 SRCE 57.6 (N/A) 0.005 TL 83.00 PV NOTES (HASS) Calculations were performed by the HASS 8.0 computer program under license no. 38021611 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.155 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 9.2 ft/sec at pipe 29. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 2.067 5.00 10.00 3.00 11.00 6.00 1.00 10.00 10.00 10.00 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkViv BfyVlv GatVlv AlmChk DPVlv NPTee 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 6.357 18.00 38.00 11.00 40.00 13.00 4.00 35.00 35.00 38.00 100. 0 A U G E 60.0 R E S S U R E 40.0 p S i 20.0 WATER SUPPLY ANALYSIS Static: 90.00 psi Resid: 89.00 psi Flow: 1989.0 gpm H 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT 2 3 4 5 6 ijurc 401.9 7 <14> 45.3 14 <22> 118.5 21 <39> 407.8 1 2 3 12 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 3/24/2010 I:\DATA\LIFE.SDF JOB TITLE: Life Technology Utility Report: Equivalent K-Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H-W Equivalent Name K-Factor (psi) (in) Len. (ft) Len. (ft) coef. K-factor ----------------------------------------------------------------------- eqk 11.20 12.80 1.049 22.00 2T2E 36.00 120.00 7.35 tqcu Fire & Building liProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (414) 570-5000 /(800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series EC-1 I & EC-14 - 112 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. SEPTEMBER, 2004 Model/Sprinkler Identification Number TY5137 - Upright, 112K TY5237 - Pendent, 11.2K 1Y6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O ESCUTCHEON PLATE SEATING SURFACE !/ 1-11/16" (42,7 mm 3/40 ** NPT 6" irn) -IT & ENT WRENCH FLAT Page 2 of 8 TFP22O 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6- Deflector* Temperature rating is indicated on deflector ** Pipe thread connections per ISO 7/1 can be provided on special request. 2 3 4 5 6* 1/2(12,7mIT) 1 NOMINAL MAKE-IN UPRIGHT PENDENT FIGURE 1 SERIES EC-1 1 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT CROSS SECTION SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB NATURAL I CHROME I WHITE LEAD LIQUID BRASS PLATED IPOLYESTER COATED 135°F/57"C Orange LIGHT UPRIGHT K=11.2 (TY5137) 1,2,3"",4 155°F/68°C Red 175°F/79°C Yellow PENDENT Refer to Table B for K=11.2 (TY5237) K14.0 (TY6237) 1,2,4 1,2,4 200°F/93°C Green 286°F/141°C Blue UL and C-UL 135"F/57°C Orange Sensitivity Rating and Refer to Table C for FM REC. PENDENT K=1 1.2 (TY5237) K=14.0 (TY6237) 1, 2, 3, 4 N/A 155°F/66"C Red 175°F/79°C Yellow Sensitivity Rating With Style 30 Escutcheon 1, 2, 4 200"F/93"C Green 286°F/141"C Blue UPRIGHT 135°F/57°C Orange ORDINARY K=11.2(TY5137) K=14.0(TY6137) and 1,2,3,4 1,2,3,4 155°F/68°C Red 175"F/79"C Yellow Refer to Table B for UL and C-UL PENDENT K11.2 (TY5237) 1, 2, 4 2000F/93°C Green 286"F/141"C Blue Sensitivity Rating K14.0 (TY6237) REC. PENDENT 135°F/57"C Orange and Refer to Table C for FM Sensitivity Rating K=1 1.2 (TY5237) K=14.0 (TY6237) With Style 40 1, 2, 4 N/A 155°F/68°C Red 175°F/79°C Yellow Escutcheon 200°F/93°C Green NOTES: 11isted by Underwriters Laboratories, Inc. (UL). 21isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the City of New York under MEA 177-03-E. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. *Frame and Deflector only. Listings and approvals apply to color (Special Order). Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS TFP220 Page 3 of 8 LIGHT HAZARD 135°F 155°F 175°F 200°F 286°F ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR 14 x 14 Style 30 Recessed - - - - - SR SR SR SR 14 x 14 Style 40 Recessed - - - - - SR SR SR SR 16x16 Up. orPend. QR* QR QR* QR* QR* SR SR SR SR 16x16 Style 30 Recessed QR* QR* QR- QR* QR* SR SR SR SR 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 18x18 Up. orPend. QR* OR* QR' QR* QR* SR SR SR SR 18x18 Style 30 Recessed QR* QR* QR* QR* QR* SR SR SR SR 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 20x20 Up. orPend. QR* QR* QR* SR* SR* SR SR SR SR 20 x 20 Style 30 Recessed QR* SR* QR* SR* SR* SR SR SR SR 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K 14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-Il OR EC-14 SPRINKLERS - (SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16x16 Up. orPend. QR* QR* N/A N/A N/A SR SR SR SR SR 16x16 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. OR* QR* N/A N/A - N/A SR SR SR SR SR 18x18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 18x18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20x20 Up. orPend. OR* OR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable * Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 1 OR EC-14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS) SR N/A N/A SR N/A N/A SR N/A N/A SR N/A N/A Page 4 of 8 TFP220 Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A for complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficients K = 11.2 GPM/psi112 (161,3 LPM/bar1l2) K = 14.0 GPM/psi112 (201,6 LPM/bar112) Temperature Ratings 135°F/57°C to 286°F/141°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ........Glass (3 mm dia.) Compression Screw ......... .........Bronze Deflector .............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). The Series EC-il and EC-14Sprin- kiers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. The Series EC-1 1 and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non-- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-1 1 and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses or bar joists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". The minimum allowable spacing be- tween the Series EC-li and EC-14 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-1 1 and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (TY5 137, TY5237, TY61 37 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutuai Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. Pipe Thread Connection UL and C-UL Listing 3/4 inch NPT Requirements TFP22O 2-7/8 DIA. 1/2±1/8 (73,0 mm) 1/2° (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) FACE OF I (57,2 mm) SPRINKLER I 4MOUNTING 1/8' FITTING I (3,2 mm) MOUNTING / SURFACE // CLOSURE PLATE - 1-3/8' (34,9 mm) 1-1/8° (28,6 mm) FIGURE 2 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON Page 5 of 8 "FITTING SIDE" TOWARDS SPRINKLER FITTING /\ WRENCH / ( RECESS END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS WRENCH HEX FIGURE 5 W- TYPE 22 RECESSED SPRINKLER WRENCH 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) I SPRINKLER 1/8" FITTING (3,2 mm) MOUNTING MOUNTING t SURFACE PLATE rm CLOSURE 1-3/8" (34,9 mm) 7/8' (22,2 mm) FIGURE 3 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Page 6 of 8 TFP220 GROUPI GROUPII LIGHT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0.10 GPM/FT2 0.15 GPM/FT2 0.20 GPM/FT2 DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 (K=11.2) UPRIGHT 14 x 14 - - 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 18x18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 TY5237 (K=1 1.2) PENDENT 14 x 14 - - 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 18x18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TV6137(K=14.0)UPRIGHT 14x14 N/A N/A - - - - 16x16 N/A N/A 39 7.8 51 13.3 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K=14.0) PENDENT 14 x 14 - - - - - 16 x 16 37 7.0 39 7.8 51 13.3 18x18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 It2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/f12 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-1 1 AND EC-14 SPRINKLERS Step 1. The sprinkler must be installed Installation with the deflector parallel to the mount- The Series EC-11 and EC-14 Sprin- klers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/1411C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40.7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. ing surface. Pendent sprinklers must be installed in the pendent position, and upright sprinklers must be in- stalled in the upright position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pen- dent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprin- klers using only the W-Type 22 Sprin- kler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Fig- ure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). TFP22O Page 7 of 8 Care and Maintenance The Series EC-11 and EC-14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fre Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OF MERCHANTABILITY AND FIT- POSE. TFP22O Page 8 of 8 Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). Recessed Escutcheon: Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL9010)*PSN 56-705-3-011 Brass Plated ..............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700-9-010 White Color Coated ........PSN 56-700-4-010 White (RAL9010)*PSN 56-700-3-010 Brass Plated ..............PSN 56-700-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 PIN 51 - AAA - B -CCC AAA = 893 (for TY5237 Ki 1.2 Pendent) AAA = 894 (for TY5 137 Ki 1.2 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AAA = 896 (for TY6137 K14.0 Upright) B = 1 (for Natural Brass) B = 3 (for White [RAL9010])* B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 1350F/57°C) CCC = 155 (for 155°F/68°C) CCC = 175 (for 175°F/79°C) CCC = 200 (for 200°F/93°C) *Eastern Hemisphere sales only. TABLE E PART NUMBERS FOR EC-1 1 AND EC-14 SPRINKLERS TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446