Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS100047; Permit4/4/25, 11:26 AM AS100047 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS100047 Job Address: 5781 VAN ALLEN WY Permit Type: SPRINK Parcel No: 2120911900 Lot #: 0 Status: ISSUED Applied 4/14/2010 Approved: 5/21/2010 Reference No.: Issued: 5/21/2010 PC #: Inspector: Project Title: LIFE TECH THREE FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON POWAY CA 858-513-4949 Owner: LEVINE INVESTMENTS LIMITED PARTNERSHIP 1702 E HIGHLAND AVE #310 PHOENIX AZ Fees ($) Balance 195 0 195 if 0 H about:blank 1/1 QUICK RESPONSE UPRIGHT CONVENTIONAL DESCRIPTION AND OPERATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHTS PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. QUICK RESPONSE PENDENT VERTICAL SIDEWALL Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (790C), 200°F (93°C), 286°F (141°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-550C). Frame - bronze c Deflector - brass • Screw - brass Bulb seat - copper c Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size. QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY I 135°F/15°F - . 57 0/68 0 ORANGE/RED . -100 38°C INTERMEDIATE 175 F1200°F .79 0/93 C IYELLOW/GREEN 150 F - 66°C HIGH - -.-.y 286F 141C BLUE 225 F iorc 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 DECEMBER 2006 A-20 BULLETIN GL5615, REV. #6 TECHNICAL DATA See reverse side for Approvals and Specifications. QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL ° CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. HORIZONTAL SIDEWALL IS 9116". 2 FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F. M. LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEAIOI-92-E GL2815 2.8 X X X X X X -- - - X GL4215 4.2 X X X X X X -- - -- X UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8° X X X X X X X - X GL81188.1 X X X X X X X X X X GL2801 2.8 X X X X X X GL4201 4.2 X X X X X X - - X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8° X X X X X X X - - X GL8106 8.1 X I X X I X X I X X X X I X VERTICAL GL5632 5.6 X X X X X X X - - - SIDEWALL GL8133 8.1 X X X X X X - - - - dL2826 2.8 X X X X X X - - -- X HORIZONTAL GL4226 4.2 X X X X X X -- - - X SIDEWALL § GL5626 5.6 X X X X X X X - - X GL8127 8.1 X X X X X X -- - - CONVENTIONAL GL5624 5.6 X X X X X (OLD STYLE) GL8125 8.1 X X X X X - X X - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12° BELOW THE CEILING, FM APPROVED 4' TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. ORDERING INFORMATION *1/2"NPT SPECIFY GLOBE® PRODUCT WARRANTY Quantity • Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) GLBE FIRE SPRINKLER CORPORATION 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com DECEMBER 2006 PRINTED U.S.A. BULLETIN GL5615, REV. #6 Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of SaFe (Our Price List).