Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5791 VAN ALLEN WAY; ; FA100067; Permit
4/4/25, 11:27AM FA1 00067 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA100067 Job Address: 5791 VAN ALLEN WY Status: ISSUED Permit Type: FALARM Applied 11/3/2010 Parcel No: 2121304500 Approved: 11/3/2010 Lot #: 0 Reference No.: Issued: 11/3/2010 PC #: Inspector: Project Title: LIFE TECHNOLOGIES T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: MARARISK CARLSBAD L L C C/O LIFE TECHNOLOGIES CORP 5791 VAN ALLEN WAY CARLSBAD CA Fees Add'I Fees Total Balance L 125 0 125 0 about:blank 1/1 r 'p LIFE TECHNOLOGY CP-3 NEW LOBBY T.I. 5791 VAN ALLEN WAY. CARLSBAD,CA. 92008 FIRE ALARM SUBMITTAL aO0 laql-A Submitted By: 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3262 Contact: GIL AGUIRRE LIFE TECHNOLOGY FIRE ALARM SUBMITTAL OLD ADT DESCRIPTION MODEL # FIRE CONTROL PANEL (EXIST) ADT-6008 REMOTE ANNUNCIATOR ADT-2001 INPUT MODULE ADT-3102 RELAY MODULE ADT-3103 MANUAL PULL STATION ADT-3401 HORN/STROBE MULTI CD T371-9308 STROBE MULTI CANDELA T371-9409 18/2 FIRE CABLE 740132 14/2 FIRE CABLE 740133 18/4 FIRE CABLE 740134 CONNECTION TO I EXISITNG DUCT DETECTOR NEW SIMPLEX MODEL # MANF. CSFM# 4008-9101 SIMPLEX 7165-0026:318 4606-9101 SIMPLEX 7120-0026:225 4090-9001 SIMPLEX 7300-0026:223 4090-9002 SIMPLEX 7300-0026:223 4099-9003 SIMPLEX 7150-0026:224 4906-9129 SIMPLEX 7125-0026:317 4906-9103 SIMPLEX 7125-0026:316 ADT/PAIGE/GENISIS 7161-1487:100 ADT/PAIGE/GENISIS 7161-1487:100 ADT/PAIGE/GENISIS 7161-1487:100 NOTE: ADT PRIVATE LABELED THE ABOVE EQUIPMENT FROM SIMPLEX AND PUT THERE PART NUMBERS ON THE DEVICES, THEY NO LONGER DO THIS SO WE MUST NOW USE THE SIMPLEX PARTS AND THERE PART #'S, THE DEVICES ARE THE SAME AND ARE STILL COMPATIBLE WITH THE ADT EQUIPMENT 4008-9101 Standard Control Panel Simplex TrueA!arm® Addressable Fire Alarm Control Panels UL, ULC Listed; FM, CSFM, Model 4008 Fire Alarm Control Panel for IDNetTM Addressable and MEA (NYC) Approved* Devices and TrueAlarm Addressable Smoke Detection R MmI4-1 Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information Operation is programmable using a multi-function keypad and the panel LCD or via service computer (PC) RS-232 service port provides upload/download PC access for panel configuration and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on-board DACT provides: Contact ID, 3/1, 4/2, BFSK, and SIA formats WALKTESYFM silent or audible system test** Voltage and current for both the battery charger and the battery can be displayed at the front panel LCD Addressable Devices: Using IDNet communications, up to 200 addressable TrueAlarm detection points or addressable device points are available (see page 3 for details)** Two Standard Notification Appliance Circuits (NACs): Class A or Class B outputs with solid state overcurrent protection per NAC, each rated for 2 A Selectable for Simplex® SmartSyncTM two-wire horn/strobe control or synchronized strobe control** Standard Power Supply: Provides 3 A maximum @ nominal 24 DC Automatic input power selection operates with 120 VAC or 240 VAC, 50 or 60 Hz On-board temperature compensated battery charger for up to 12.7 Ali batteries in cabinet (UL and ULC) and up to 25 Ali batteries in separate cabinet (UL only) Additional standard features: Two auxiliary relays NACs, Relay outputs, and communications circuits are power limited per NFPA 72® (AC input, battery circuits, and City Circuit Module outputs are non-power limited) UL listed to Standard UL 864, 9th Edition Available option modules: Door mounted 24 LED annunciator (standard on ULC model) 3 A Expansion Power Supply with two on-board 2 A NACs that operate the same as standard NACs City Interface Module and Auxiliary Relay Module Remote LCD and LED/Switch Annunciators : - - . — POW rm1; 4008 Film AlwmCmkd 4008-9121 Control Panel with 24 LED Annunciator (required for ULC applications) I Dcserintinn For areas requiring up to 200 addressable input devices and up to 4 NACs, the Simplex 4008 Series fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific 20 character custom labels. See page 2 for additional ULC and MEA information. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:313 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Additional listings may be applicable, contact your local Simple69) product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. TrueAlarm analog smoke detection is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777. IDNet addressable communications are protected by U.S. Patent No. 4,796,025. IDNet duplicate device detection is protected under U.S. Patent No. 6,034,601. WALKTEST system testis protected under US Patent No. 4,725,818. SmartSync horn/strobe operation is protected under U.S. Patent No, 6,281,789. Two-wire synchronization circuit operation is protected by U.S. patent No. 5,559,492. S4006-0001-3 7/2005 IUi171 IT-UM F1 Addressable operation is provided by an IDNet signaling line circuit (SLC) capable of communicating to up to 200 addressable devices (points). Addressable devices include: TrueAlarm smoke detection, heat detection, and duct detection; supervised addressable modules for single and multiple contact monitoring, manual stations, isolation modules, and a remote signal module (see list on page 4.) (Please note that this panel provides a limited TrueAlarm operation feature set. For larger applications that require the full complement of TrueAlarm features, contact your local Simplex product supplier.) Two, 2 A On-Board NACs provide conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection. Operation is selectable for synchronized strobe or SmartSyncTM horn/strobe two wire operation. Horn control can be selected at the panel for: Temporal pattern coding, Steady On, Slow March Time (20 beats per minute), or Fast March Time (120 beats per minute). Note: When selected for SmartSync horn/strobe control, March Time produces 60 beats per minute. The 24 VDC Auxiliary output provides up to 500 mA for system use. (Auxiliary output current is counted for total power supply capacity.) Standard Auxiliary Relay Outputs. Two relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC per below: Aux Relay 1 is normally assigned to General Alarm operation but is programmable (see page 7) Aux Relay 2 (Trouble) is energized when Normal and is de-energized with a Trouble condition. On-Board Dual Line DACT. Operation can be selected for Contact ID, SIA, 3/1, 4/2, and BFSK formats. Reporting includes Alarm, Supervisory, Trouble, and AC Failure. Operation includes automatic 24 hour test and programmable power fail report delay. Power Supply and Battery Charger. DC power output is 3 A @ 24 VDC for panel use. The temperature compensated battery charger (sealed lead-acid batteries only) is rated for up to 25 Ah batteries per UL 864 and up to 12.7 Ah per ULC-S527. (Up to 12.7 Ah batteries fit in the cabinet, larger batteries require an external cabinet.) Panel electronics can measure and display voltage and current for the power supply, batteries and the battery charger (standard and expansion power supply). Depleted battery trouble is monitored and annunciated and depleted battery cutout can be selected. Active battery status monitor supervises charger operation. WIG 1T1T'I rn7i1.1T1 Expansion Power Supply. Provides 3 A total @ 24 VDC, two additional 2 A NACs, and an additional auxiliary power output of 500 mA. Output operation is the same as on the standard power supply. Expansion Relay Module. Provides three relays, one each for Alarm, Supervisory, and Trouble conditions. Each is jumper selectable as N.O. or N.C. Contacts are rated 2 A @ 30 VDC. Location is the same as for the City Circuit Modules. City Circuit Modules. These modules are available with or without on-board disconnect switches, depending on local requirements (either type can be disconnected through the front panel under password control). Connections are for Remote Station (reverse polarity) or Municipal Master (local energy). Reporting includes A1..... C...,...... ruaLLu, .upLv1au1y, and 11UUU1i. Control Panel Model Description Listings I 4008-9101 Standard fire alarm control panel UL FM MEA - 40 9121 Fire alarm control panel with & CSFM ULC 24 LED Annunciator on front door ox Depth Standard Features 4-1/4" Red cabinet; SLC with 200 addressable points, 108 mm) 2 Class B/Class A NACs, 3 A power supply with battery charger; on-board DACT; for input 4-5/8" 117 mm) voltage of 120/240 VAC, 50/60 Hz (autoselect) Option Modules Model Description 4008-9801 Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, 50/60 Hz Select one if required 4008-9802 Expansion Relay Module; 3 relays selectable as either N.O. or N. C. 4006.9805* City Circuit Modules with disconnect switch Select one if required 4006.9806* City Circuit Modules without disconnect switch * These City Circuit modules are also used on the 4006 Series control panels. Accessories Model Description 2975-9812 Red Semi-Flush Trim; 1-7/16" wide (37 mm) - 4009-9801 Beige External Battery Cabinet for up to 25 Ah batteries; mounts close-nippled to control panel cabinet; dimensions = 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) [depth increased for 25 Ah effective 7/2005] Batteries, 12 Volt (select one battery model per system standby requirements; order quantity of two) Model Size Model Size Location Model Size Location 2081-9272 6.2 Ah 2081-9288 12.7 Ah For cabinet mount 2081-9275 18 Ah Requires 4009.9801 External Battery 2081-9274 10 Ah 2081-9827 25 Ah Cabinet (UL listed only) S4008-0001-3 7/2005 ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Alarm list SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the active Supervisory list FIVE NAVIGATION KEYS: MENU selects the on-screen programming menu; left and right arrows moves the position on the screen, and PREVIOUS and NEXT navigate screen selections r SY5TEM NORMAL 35: 15 F,m 0'0'05 J. j.•:' .. 71 SYSTEM RESET restores control panel to normal when 1J . all alarmed inputs are returned tonormal - -i,- -, • I V - ALPHANUMERIC LI KEYPAD provides i I programming entry of -. ;: ' tnumbers and letters I I \ ALARM SILENCE causes audible notification appliances 3 S4008-0001-3 7/2005 TROUBLE ACK acknowledges to be silenced, used after evacuati on is complete and system troubles, logs th e while \ alarm source is being investigated acknowledge, silences the operator panel and all annunciator tone-alerts, and steps through the FOUR EXTENDED FUNCTION KEYS: ENTER confirms active Trouble list selections, EXIT/CLEAR backs out of the present screen menu and dears information that has not been entered, FUNCTION enables the active function menu, DISABLE/ENABLE toggles the function or circuit status as appropriate per the selected screen TrueAlarm Addressable Detection. IDNet addressable device compatibility includes Simplex TrueAlarm photoelectric smoke and temperature sensors. The 4008 fire alarm control panel provides a subset of the complete analog TrueAlarm features. TrueAlarm sensors appear to the panel essentially as addressable detectors and that term is used for 4008 documentation. Approximately every four seconds the addressable smoke detectors transmit an output value based on their smoke chamber condition. The panel CPU internally maintains a current value, peak value, and an average value for each detector's output. Status is determined by comparing the current value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Alarm Determination. Photoelectric detection sensitivity is 2.50/o/ft obscuration. All detectors can be selected for a reduced sensitivity detection mode that satisfies the city of Boston requirements. Addressable heat detectors provide a fixed temperature alarm at 135° F (57° C) and may be individually selected to also provide rate-of-rise alarm of 150 F (8.3° C) per minute where applicable. LiLIht.11I4*1itoI iT ETII II P1!2F1'J Status Monitoring. 4008 TrueAlarm operation provides the ability to automatically indicate when an addressable detector is dirty or excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the detectors is fulfilled by the TrueAlarm ability to maintain the sensitivity level of each addressable detector. Modular Addressable Detector/Base Combination. Modular TrueAlarm addressable detectors use the same base which allows different detector head types (photoelectric smoke, or heat) to be easily interchanged to meet specific application requirements. This feature also allows intentional detector (sensor head) substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke detectors (causing them to be disabled), heat detector heads may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect detector type, the heat detector will operate at a default setting to provide heat detection for building protection at that location. keyboard Reference FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset THREE PROGRAMMABLE LEDs custom labeling (labels insert into 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal o perating conditions, provides up to 20 characters for custom label information [provide a pocket), the top two LEDs are FIRST ALARM DISPLAY: Operation can be selected for maintained display of first selectable as red or yellow, the bottom LED is selectable as green or yellow alarm until acknowledged Compatible Simplex Peripherals (see specifications on page 5 for notification appliances) Detector Heads and Addressable Bases (refer to page 3 for 4008 detector/sensor terminology) Model Detector Head Type Compatible Addressable Base - Data Sheet 4098-9792, Standard detector base 4098-9789, Base for remote LED or relay 4098-9714 4098-9733 Photoelectric Heat, 135° F (57° C) S4098-0019 ___ 4098-9791 Features of 4098-9789 and remote supervised relay 4098-9794, Sounder base S4098-0028 4098-9793, IDNet Isolator base S4098-0025 4098-9754 Photo and Heat 4098-9795, Dual address sounder base I NOTE: These bases require I two addresses S4098-0033 4098-9796, Dual address standard base Duct Detection Model Description DataISheet , 4098-9755 Addressable Duct Detector Housing with 4098-9714 detector, no relay control 4098-9756 Addressable Duct Detector Housing with 4098-9714 detector, with remote relay control S4098-0030 Addressable Devices Model and Description Data Sheet Modeland Descnption Data Shet IMo del and Description Data Sheet i 4090-9001 Supervised lAM S4090-0001 4090-9101 CL B ZAM I S4090-0003 4090-9007 Signal lAM S4090-0010 4090-9051 Supervised 1AM 4090-9106 CLAZAM 4099-9001, 4099-9002, & 4099-9003 Manual S4099-0001 4090-9002 Relay lAM S4090-0002 4090-9116 IDNet Isolator S4090-0005 Stations Compatible System Expansion Panels Model Type Description Data Sheet 4003 Series Voice Control Panel Provides a remote voice control panel with on-board NACs, internal S4003-0001 microphone, and remote microphone input 4009 Series Remote NAC Extender Provides remote NACs; includes power supply and battery charger; S40090002 4 extenders max/NAC; 4008 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals. -tc Annriniitnr flritic The 4008 supports up to four annunciator options including: 4606-9101 LCD Annunciator Features: Door Mounted 24 LED Annunciator LCD readout with two lines of 40 characters each and 4610-9111 Remote LED/Switch Annunciators LED backlighting 4606-9101 Remote LCD Annunciators Wide viewing angle, super-twist design Annunciators communicate at a rate of 9600 baud with Keyswitch access controlled power supplied by separate wiring. Control switches and status LEDs for: 4610-9111 LED Annunciator Features: Alarm, supervisory, or trouble acknowledge 16 LEDs with programmable functions and dedicated Alarm silence and System Reset LEDs for Alarm Silenced, Lost Communications, Three programmable LED indicators: Trouble, and Power-on Keyswitch access controlled switches for Two LEDs are selectable as red or yellow Acknowledge, Alarm Silence, Reset, and Lamp Test One LED is selectable as green or yellow Local tone-alert With provisions for custom labeling SYSTEM IS NORMAL I OSémpê 4610-9111 LED/Switch Annunciator 4606-9101 LCD Annunciator 4 S4008-0001-3 7/2005 Specifications (Refer to Installation Instructions 579-716f or additional information) Input Voltage 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select AC Input Input Current, Standard 2 A maximum @ 120 VAC input; 1.5 A maximum @240 VAC input Input Current with Expansion Power Supply 4 A maximum @ 120 VAC input; 3 A maximum @240 VAC input Power Supply Output 3 A maximum @ 24 VDC in alarm Battery Charger Temperature compensated charger is rated for up to 25 Ah per UL 864; up to 1 12.7 Ah per ULC-S527 Notification Appliance Circuits (NACs) (NOTE: Total DC current = 3 A maximum per power supply) General Rating 2 A maximum @ 24 VDC, per NAC; available as Class A or Class B; Class .B end-of-line resistor = 10 kfl, 1/2W; Model 4081-9008 (PIN 733-894) Special Application Rating = per NAC Simplex 4901 Series (horns) and the following 4906 Series Multi-Candela: strobes, Strobe synchronization is UL listed across all hom/strobes, and speaker/strobes (see data sheets S4906-0001, S4906-0002, & four system NACs for these 4906 Series s4906-0003) appliances 4906-9101 I 4906-9103 I 4906-9127 I 4906-9129 I 4906-9151 I 4906-9154 4906-9102 4906-9104 4906-9128 4906-9130 4906-9153 Regulated 24 VDC Rating = L5 A per NAC NOTE: Maximum strobe load on main power supply or expansion power supply is 1.35 A All other UL Listed Notification Appliances; use associated external per power supply (2.7 A total); remainder of synchronization modules where required power supply rating is available for other loading Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum per power supply) Auxiliary Power Output 500 mA maximum @24 VDC Standard Auxiliary Relay Outputs Relay I Programmable operation Contacts rated 2 A @ 30 VDC, 0.35 power factor; Relay 2 t Trouble operation jumper selectable as N.O. or N.C. Wirinq Connections t Terminals rated for 18 AWG to 12 AWG (0.82 mm to 3.31 mm2 IDNet Communications Quantity Up to 200 addressable devices (see list on page 4) Suppression For wiring external to building, use Overvoltage Protector 2081-9044 at each end of the connection; refer to data sheet S2081-0016 for details Wire Size 18 AWG (0.82 mm') Unshielded twisted pair (UTP) Acceptable for most applications; not for use with wiring in conduit with either NAC or AC power wiring (or similar) Wire Types Shielded wire may provide protection from unexpected sources of interference and Shielded twisted pair (STP) may be required for some applications; review system with your local Simplex product supplier Distance from Control Panel to Farthest Up to 4000 feet (1219 m)with 125 devices; 32 9 Device Up to 2500 feet (762 m) with 200 devices; 51 c Total Wire Length Allowed With "T" Taps for Up to 10,000 ft (3 km) Class _B_Wiring Total Capacitance Allowed 0.6 .iF (600 nF) Annunciator Communications Quantity Supported Up to four annunciator modules per panel (see page 4 for details) Wiring Size and Type See description for IDNet wiring above Wiring Distances Bus-Style Wiring Up to 4000 ft (1219 m); 0.58 pF (580 nF) maximum capacitance; 35 ) max. Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device "T-Tap" Wiring Line Matching Resistor Bus-Style Wiring Connect one at panel 100 c, 1/2W; 4081-9011; "T-Tap" Wiring Connect one at panel and one at end of line (part number 733-974) Suppression Use 2081-9044 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet S2081-0016) Option Module Ratings Expansion Relay Contact Ratings 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module 4008-9802 Wiring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) Environmental Ratings Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range Up to 93% RH, non-condensing @ 100.4° F (38° C) maximum 5 34008-0001-3 7/2005 Supervisory and Alarm Currents Model Module Supervisory Alarm 4008-9101 Standard fire alarm control panel with 50 175 mA 200 mA IDNet devices 4008-9121 Control panel with 24 LED Annunciator 193 mA + 1 mA per IDNet device 250 mA+ 1 mA per IDNet device 4008-9801 Expansion Power Supply 50 mA 60 mA 4008-9802 Expansion Relay Module 10 mA per energized relay 10 mA per energized relay 4008-9805 City Circuit Module with disconnect switch 30 mA 60 mA 4008-9806 City Circuit Module without disconnect 30 mA 60 mA switch 4606-9101 Remote LCD Annunciator (see data sheet 100 mA 150 mA S4606-0001) 4610-9111 Remote LED/Switch Annunciator (see 40 mA 70 mA data sheet S4610-0001) (all LEDs and tone-alert on) ** Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Addressable Device Information The following addressable device types and hardware point types are provided. A combination of autoprogram, and either front panel or PC programming allows the operation to be selected per application. Available Fire Detection Device Types Device Description Options - - - Photoelectric TrueAlarm operation with Sounder base (selectable With communications isolator for single station operation) Addressable Detector sensitivity = 2.5%/ft With relay output Selectable for all detectors to be at city of Boston sensitivity of 3.7%/ft Sounder base (selectable With communications isolator Heat Detector Fixed temperature thermal for single station operation) With relay output Individually selectable to add rate-of-rise heat detection at 135° F (57.2° C) detection of 15° F/minute (8.3° C/minute Addressable Hardware Point Types Function Type FIRE Description Fire monitor device - Function Type WSO Description - - Combination waterfiow and water supervisory device WATER Waterfiow monitor device SUPV Supervisory monitor HEAT Heat detector device UTIL Supervised utility monitor DUCT Duct detector device TROUBLE Trouble monitor PULL Manual (pull) station device VSMOKE Verified fire alarm; an alarm level causes the alarm verification cycle to start SMOKE Smoke detector device STYLEC Style C fire monitor SO Sprinkler Supervisory LATSUPV Latching supervisory monitor (supervisory latches until system is reset) S4008-0001-3 7/2005 The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations Function Type Relay Activates Upon Relay Deactivate, Upon SRELAY General Alarm I Silence RRELAY General Alarm Reset SUPV Supervisory condition Clear TRBL Trouble condition Acknowledged Special Functions Function Type UTILITY Description - - Utility input in the same alarm group activates PRIMARY General alarm; relay is tied to Primary Elevator Recall contacts ALTERN General alarm; relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4-wire addressable detectors; relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and close doors Additional Programming Feature Details FunctIon Details Custom labels Up to 20 characters per point; a built-in message library provides for commonly used words for easy front panel programming For front panel label creation convenience, the following words can be selected as part of a custom label (_designates a built-in space; typing the first letter of a word/number will select the closest word in alphabetical/numerical sequence) Message Library North Center 3 Basement Fir Floor Lobby main Boiler_RM Elevator South rear Flr4 Garage Office first Classroom Entrance Storeroom East 5th Flr_5 Hallway Patient 2nd Closet_ Restroom Wing West Fin RM_ HVAC_Room upper 3rd Corridor Room Zone Front Flr_2 Kitchen lower 4th Elect - RM Stairway Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS-232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprogram modes are available to detect new modules only, recreate default programming and then add all modules found; Scans of addressable loop adds addressable devices, displays total added; checks for duplicate addresses and identifies errors Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with inputs according to local response requirements WALKTEST Allows one person to perform system testing; alarm or trouble tests are followed by automatic reset; the alarm zone is sounded out by associated audible notification or the response is silently logged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Passcode Protection Level 2 = All Level 1 + Set Time/Date, Point Control, Enable/Disable points (4-digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and WALKTEST Level 4 = All Level 3 + Programming, Upload/Download; this is the Service access level S4008-0001-3 7/2005 Installation and Module Placement Reference 4 Box width 15-5/8" (397 mm) M are top s 11-1/4" (286 mm) (Top and side views are shown with door installed) Box depth = 4-1/4" (108 mm) standard 4-5/8" (117 mm) w/annunciator door 1-4 DOI Ii i_ 0 518" (16 mm) I fl *ocl ___ _______ I ___ _______ I I 13-1/2" rDisim 16" _________ r Expansior\ Door thickness_ iJ I (343 mm) I,AssmbIyJ 7 11171 I P ower Supply*) (406 mm) rQ(—A(C Input Terminals) L 1 • Module* I or Expansion I Battery Area eIay Module*J - [ No conduit or wiring in this area __J -- _ - 4_13-1/4" (337 mm) NOTE: For semi-flush mounting, cabinet * Indicates optional modules must extend 1-1/2" (38 mm) minimum from wall surface Door LED Annunciator Details - LED) (RED LED 14 CUSTOM LABEL AREAS are typically for location identification and NAC (shown labeled for AREA i 1:: 5 9available, AREA 2 __ annunciation blank labels are ___ I AREA AREA6 10reference, UAREA10 provided); dual LED locations have AREA 7 a AREA 3 labels insert into pockets Red LED (top) and a Yellow LED ___(bottom); the overlay; LED operation AREA 4 AREA8behind is programmable to track other monitored status conditions FOUR YELLOW LEDs provide default NAC Trouble annunciation (shown labeled as NAC 1-4) Tyco, Simplex the Simplex logo, TrueAlarm, IDNet, WALKTEST, and SmartSync are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). SinipIex Tyco Safety Products Westminster• Westminster, MA - 01441-0001 • USA S4008-0001-3 7/2005 www.tycosafetyproducts-usa-wm.com 0 2005 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0318 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4006-9101, *40069102 4006-9121, *40069122 4008-9101, *4008..9102 4008-9121 and *4008..9122 Commercial Fire Alarm Control Panels. Local, auxiliary, remote station and central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: **4006..9101 -9102 Main System Board 4006-9801, 4008-9801 Expansion Power Supply (EPS) 4006-9805, -9806 City Circuit Modules (CCM) 4006-9804 Class A Adaptor (CIA) 4006-9803, 4008-9802 Relay Modules (ARM) 4006-9802 Expansion Initiating Device Circuit (XIUM) 4090-9007 IDNet Signal Individual Adapter Module (Sigl) RATING: 120v,60 Hz, 2A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: *For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev. 11-09-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division €3®Simplex System Accessories, LCD Annunciators UL, UL C, CSFM Listed; FM Approved; 4606-9101 LCD Annunciator for 4010,. MEA (NYC) Acceptance* 4006, and 4008 Fire Alarm Control Panels Remote LCD annunciator for use with Simplex® model 4010, 4006, and 4008 fire alarm control panels LCD readout provides: Two lines of 40 characters each Wide viewing angle, super-twist design LED backlighting Control switches and status LEDs for: Alarm, supervisory, or trouble acknowledge (keyswitch access controlled) Alarm silence System reset Three programmable LED indicators: Two LEDs are selectable as red or yellow One LED is selectable as green or yellow With provisions for custom labeling Additional features: Information is transmitted over a single twisted, shielded pair; separate wiring is required for 24 VDC control panel power Tone-alert sounder provides local audible indication Lamp and LCD are functionally tested each time the keyswitch is turned on Mounts flush on standard 6-gang electrical box Mounting and trim options: Surface mount box model 2975-9217 (ordered separately) Brushed aluminum trim model 4603-9111 (ordered separately) [Description Local Annunciation. 4606-9101 LCD Annunciators allow compatible fire alarm control panels to provide information and control switches at convenient locations away from the control panel. The LCD is an 80 character, back-lit, alphanumeric display with information presented in clear and descriptive English. Typical content includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, troubles, and custom location labels up to 40 characters long. (Some 4006/4008 messages are limited to 20 characters, refer to the control panel documentation for additional information.) 06 SYSTEM IS NORMAL 4606-9101 LCD Annunciator Description (Continued) Communications. Data communications require a single twisted, shielded pair that supports other annunciators on the same communications channel. Model 4010 Series panels control up to six annunciators; model 4006 and 4008 Series panels control up to four annunciators. Indications. Alarm, Supervisory, and Trouble conditions are also indicated by dedicated LEDs and a tone-alert audible indication. Each condition has a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Activity Scrolling. Repeated operation of the appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. The internal tone-alert also sounds to indicate the operation of any of the push-button switches. Operation Keyswitch Access. All switches on the annunciator are controlled by the "ENABLE" keyswitch with a key that is removable only in the disabled position. Enabled Operations. When enabled, notification appliances can be deactivated by pressing the "ALARM SILENCE" switch. Pressing the "SYSTEM RESET" switch restores the system to normal operation. When system activity is normal, the LCD displays the time, date, and "SYSTEM IS NORMAL." This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7120-0026:225 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4606-0001-5 2/2006 Model Description 4606-9101 Remote LCD Annunciator with beige trim 4603-9111 Brushed aluminum trim option Refer to specifications on page 3 2975-9217 Matching surface mount box; ivory finish for additional details 4081-9011 Line matching resistor harness; 100 n, 1/2 W; (reference no. 733-974) 2081-9044 Overvoltage protector; required where annunciator communications and power wiring exits and enters a building; refer to data sheet S2081-0016 for details 14606-9101 Operator Information 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information; THREE PROGRAMMABLE LEDs, LEDs flash to indicate the condition and then when each with custom labeling pocket acknowledged, remain on steady until reset LE SYSTEM IS NORMAL 12: 35: 15-,1 MON 30 JAN 06 Z' -- ______ ' 11) 13 Simplex ALARM ACK acknowledges a Fire Alarm condition and silences the panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions and silences the panel and all annunciator tone-alerts TROUBLE ACK acknowledges system troubles and silences the panel and all annunciator tone-alerts CONTROL ENABLE KEYSWITCH controls all switch functions; key is removable only in disabled position SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal ALARM SILENCE causes audible notification appliances to be silenced; used after evacuation is complete and while alarm source is being investigated 2 S4606-0001-5 2/2006 14606-9101 LCD Annunciator Specifications General Operating Specifications Voltage 18 to 32 VDC, system supplied Normal Operating Current 110 mA (with LED backlighting on) Battery Standby Current 65 mA (during battery backup, LED backlighting is turned off after 30 seconds without switch activity) Alarm Current 140 mA maximum (LED backlighting is on and tone-alert is sounding) Operating Temperature Range 320 to 120° F (00 to 490 C) Operating Humidity Range Up to 93% RH, non-condensing at 100° F (38° C) Communications For 4010 Panels* Type N2 external annunciator communications line Up to 6 annunciator modules total, 4606-9101 or 4605 series, 24 point I/O modules Capacity Type N2 communications format but with different capacity For 4006 & 4008 Up to 4 annunciator modules total; compatible with 4606-9101, 4610-9111, and Panels* Capacity door mounted LED annunciator Data Single twisted, shielded pair, 18 AWG (0.82 mm2) Wiring Requirements Power and Earth 18 to 12 AWG (0.82 mm2 to 3.31 mm2) wires for 24 VDC system power and Earth ground for electrical box (ground per local code) Bus-style wiring Up to 4000 ft (1219 m); 0.58 pF (580 nF) maximum capacitance; 35 rl maximum Distance resistance "1-Tap" wiring Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Line Matching Bus-style wiring Connect one at panel and one at end of line 100c, 1/2W; PlD4081-9011; Resistor "1-Tap" wiring Connect one at panel and one at farthest device (part number 733-974) Mounting Information Trim Dimensions 4-1/2" H x 11-13/16" W (114 mm x 300 mm) Assembly Depth 1-5/16" (33 mm), 1-1/2" at terminal block location (38 mm) Standard Trim Finish Steel, painted beige 4603-9111, Optional Trim Brushed aluminum (ordered separately) Boxes for Masonry boxes Flush Mounting Single gang boxes Six-gang box, 2-1/2" (64 mm) deep minimum RACO # 960, 2-1/2" deep or RACO #965, 3-1/2" (89 mm) deep or equal Six, single gang boxes, 3-1/2" (89 mm) deep minimum, RACO #600 or equal (supplied by others) Box selection note Conduit entrance is box dependent, refer to additional mounting information on page 4 and Installation Instructions 574-188 2975-9217, Surface Mount Box Option** (ordered separately) Dimensions 112" Wx4-5/8" H x 1-3/4" 0(305mm x117 mmx44 mm) Finish IPted steel, ivory finish - - -- * Refer to control panel data sheets S4010-0001, S4006-0001, and S4008-0001 for additional information. ** Reference Wiremold box number V5748-6. S4606-0001-5 2/2006 Mounting Information Flush Mount Ganged Boxes: Use 6-gang box, 3-1/2" (89 mm) mm. depth, RACO # 590 using knockouts 2-1/2" from front, or RACO # 600 using side knockouts or rear cable clamps, or equal (supplied by others) Flush Mount Masonry Box: Use 6-gang box, RACO #960, 2-1/2" deep -, (64 mm) using top or bottom knockouts, or RACO #965, 3-1/2" (89 mm) deep, using knockouts 2-1/2" from front, or equal (supplied by others) U U UU UU UJ U U U oU Surface Mount Box: Simplex model 2975-9217 (ordered separately) Trim plate —4k 0 H I 0 0 0 0 0 0 Terminal block access at rear of enclosure, this side Annunciator Assembly NOTE: Enclosure extension into box is 10" W x 2-5/8" H x 1-5/16" D, 1-1/2" deep at terminal block access, offset to left (254 mm x 67 mm x 33 mm, 38 mm), select conduit entry accordingly. Wiring Reference Interconnection Wiring Notes: Communications require a single 18 AWG twisted, shielded pair. Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus Earth Ground to each electrical box. Refer to the installation instructions supplied with the compatible control panel for additional information 4606-9101 LCD Annunciators 4010/4006/4008 Fire Alarm Control Panel (4010 shown for reference) 23co, Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. Wiremold is a trademark of The Wiremold Company. .Simplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4606-0001-5 2/2006 www.ticosafetyproducts-usa-wm.com 0 2006 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice CALIFORNIA. DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7120-0026:0225 Page 1 of 1 7120--ANNUNCIATORS Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com Models* 4606-9101 remote LCD annunciator and 4605-840124 point I/O module. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as annunciator and accessory for use with Simplex's separately listed fire alarm control units. NOTE: *Rece 03-29-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ . the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division fjSimplex Multi-Application Peripherals UL, UL C, CSFM Listed; FM Approved; lDNetTM and MAPNET Il® Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (lAMs) I Ii*i IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from lAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4008, 4010, and 4100U fire alarm control panels for IDNet communications Model Series 4100/4100U, 4120,4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 4090-9001 Supervised lAM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) ioscri ntie Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for IDNet and MAPNET II addressable communications are protected under U.S. Patent use - City of New York Department of Buildings - MEA35-93E. Additional listings maybe Nos. 4,796025; 5,966002; and 6034,601. applicable: contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0001-9 8/2010 Dnritir, Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). [sui i all"IMITTIffsi xiti 71 ITU For use with IDNet communications only, these JAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. I ri'iI IlTrE-1Ft1 Model Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals; see applicable options below - 4090-9051 1 Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description - 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference-'k;—:1 Description 4081-9004 733-886 6.8 k, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision - 4081-9003 733-896 4.7 kn, 1/2 W 4081-9005 733-984 1.8 kn, 1/2W Use for current limited monitoring applications Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per [AM Input Requirements Normally open, dry contacts 4090 9001 Wire Connections - 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Installation Instructions Reference Documents Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation: 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 rn) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) per channel, MAPNET or Mechanical Dimensions 4090-9001 4090-9051 1-9/16" W x 1-3/4"H x 1-1/4"D (40 mm x 44 mm x 32 mm) 1-9/16" W x 1-9/16" H x 9/16" 0(40mm x40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32 to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0001-9 8/2010 i -_ 1H EDOEflIOt 141- 1150 01131 DAIS CODE LED viewing port Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 4-114' (108 mm) _ Light pipe for © LED viewing 4-1 . /2" I I CT (114 MM) DISCONNEcT 3ER DISCONNE FOER L BEFORE SEICING j LEFORE SEE V.CING © © CD 2-1/2' ___ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2-13/16" (72 MM) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-9 8/2010 409O-9O51 Mounting Information Address setting is at rear of housing Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, the Simplex logo, IDNet, and MAPNETII are trademarks of Tyco International Ltd. and its affiliates and are used under license. Simplex Tyco Safety Products Westminster• Westminster, MA •01441-0001 USA S4090-0001-9 8/2010 www.tycosafetyproducts-usa-wm.com © 20)0 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class "A" ZAM Initiating Module; 4090-9101, -91O1TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: *Rece 03-29-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an °j endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division £®Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, lDNetTM Communicating Devices and MEA (NYC) Approved* Model 4090-9002 Relay lAM IDNet addressable interface modules** for use with Simplex® models 4010 and 4100U fire alarm control panels 4090-9002, Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 I ' IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. 1=0 qRq -n rtrii Model Description 4090-9002 Relay lAM Optional Trim Plates Model Description 4090-9801 Trim plate with LED For semi-flush viewing window, includes mounted box mounting screws; For surface 4090-9802 galvanized steel mounted box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026223 for allowable values and/or conditions concerning material presented in this document. his subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. 4090 Series IDNet Relay lAM Package (shown approximately 1/2 size) (Refer to Installation Instructions 574-184 for additional information.) Communications 4010 or 4100U IDNet, 1 address per device Relay lAM Power Supplied by IDNet communications Type Form C, SPDT 2 A @24 VOC, for transient Contact Power-Limited suppressed loads I A @ 24 VDC for inductive loads Ratings 1/2 A @ 120 VAC, for transient Nonpower-Limited suppressed loads Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2 ) Up to 2500 ft (762 m) from fire alarm control panel Up to 10,000 ft (3048 m) total wiring IDNet Wing Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4-1/8" H x 4-1/8' W x 1-3/8' D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C), intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) IDNet addressable communications are protected by U.S. Patent No. 4,796,025. S4090-0002-6 212004 Relay lAM Mounting Information Address setting under resealable label 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) IN Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © Light pipe for LEE viewing 4-9/16" 4-5/16" (116 mm) ES LsJ (109 mm) © © © - 4-9/16" (116 mm) (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Tyco, Simplex, the Simplex logo, and IDNet are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. .Simplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4090-0002-6 2/2004 www.fycosafetyproducfs-usa-wm.com © 2004 7vco Safety Products Westminster. All rights reserved. All specifications and other information shown were cusrent as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106T5P, and-91061TP Class "A ZAM Initiating Module; 4090-9101, -91O1TSP, and -9I01TTP Class B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: *Rec 03-29-2006 jw TF This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division fiSimplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; lDNetTM or MAPNET Il® Communicating Devices MEA (NYC) Acceptance* Addressable Manual Stations OTTR * Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair** Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4008, 4010, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes I ir.i 1111 The Simplex model 4099-9001 addressable station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (JAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. * Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. 4099-9001 Addressable Manual Station (front and side view) E Ell I KEY OPERATED - - 4099-9002 4099-9003 With 2099-9828 Breakglass Push Institutional Cover kit offlom Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. IDNet and MAPNET II addressable communications designs are protected by U.S. Patent No. 4,796,025; 5,966,002; and 6,034,601. S4099-0001-7 5/2006 II FIRE [SimpIex] L9 Mount flush or with 1/16°(2mm)- e. 0 maximum extension 4" Square box DO NOT RECESS with plate I _________________ Station / I 0' side view Single gang cover plate, 3/4° _- I (19 mm) extension, RACO #773 - -- -I or equal (supplied by others) - Single gang Wall surface box outline Semi-Flush Mount Side View S4099-0001-7 5/2006 Addressable Manual Station Product Selection Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model 4099-9001 Description Single action, English Housing FIRE ALARM Pull Lever PULL DOWN Listings UL, ULC, FM, CSFM, MEA 4099-9001 CB Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC, FM 4099-9001 CF Single action, French ALARME FEU ABAISSEZ 4099-9002 Double action, Breakglass operation, English FIRE ALARM Double action, Push operation, English PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Accessories Model 2975-9178 Description + •. + Surface mount steel box, red Refer to page 3 for dimensions Cast aluminum surface mount box, red 2975-9022 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 Surface trim plate for Wiremold box V5744-2, red 2099-9814 2099-9819 Flush mount adapter kit, black Refer to page 4 for details Flush mount adapter kit, beige 2099-9820 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 [Specifications Power and Communications IDNet or MAPNET II communications, I address per station Address Means Dipswitch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5° H x 3-3/4" W x 1" D (127 mm x 95 mm x 25 mm) Addressable Manual Station Semi-Flush Mounting Single Gang Box Mount Single gang box, 2-1/2° deep (64 mm), RACO #500 or equal (supplied by others) C 00 L 1V 4" Square Box Mount 4" (102 mm) square box, 2-1/8"(54 mm) minimum depth, RACO #231 or equal (supplied by others) Addressable Manual Stations Surface Mounting 2975.9022 Cast Box 5" H x 3-7/8" W x 2-3/16" 0 (127 mm x 98 mm x 56 mm) (ordered separately) Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 0 0 0 FIR] FULL DOWN ___________________________ Access for 3/4" threaded conduit located top and bottom _L I simpiex ________________________ 1" (25.4 mm) - 3-3/4 (95 mm) 4099 Series Addressable Manual Station 2975-9178 Box 5-3/16" H x 4" W x 2-3/16" D (132 mm 102 mmx56 mm) (ordered separately) Knockouts located top and bottom 5" (127 mm) Surface Mount Side View with Internal Detail Field wiring (shown for reference) Address setting under resealable label (accessible with cover open) Station cover hinges open for installation access 1-1/4" (32 mm) Simplex 2975-9178 box / (shown for reference) 2-5/8" (67 mm) Switch wiring (prewired) Refer to NFPA 72, the National Fire Alarm Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. Mounting shall be with the operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft (1.37 m) above floor level. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-7 5/2006 Wiremold receptacle box model V5744-2 (supplied by others) Two gang switch box, each 3"Hx2"Wx2-314"D (76 mm x 51 mm x 70 mm) (supplied by others) 2099-9814 Surface trim for Wiremold box 5-1/8"Hx5"W (130mmx127mm) I 4099-9001 IDNet addressable station 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W—e (l52mmxll4mm) Addressable Manual Station, Additional Mounting Information For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in the illustration to the right. Flush mount adapter kit 2099-9819, Black 2099-9820, Beige k _-....._ ,- Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) 8" (203 mm) 6" (152 mm) Hole cutout must be a I minimum 0f6"H by5"W (152 mm by 127 mm) 0 0 0 0 0 Wall 4 4-3/4" (121 mm) surface -4 6-3/4" (171 mm) Front View 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Side View Tyco, Simplex, the Simplex logo, MAPNETJJ, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. 5Siniplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4099-0001-7 5/2006 www.tycosafetlproducts-usa-wrh.com 0 2006 Tyco Safety Products Westminster. All rights reserved. All spec(fications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:0224 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4099-9001, -9002, -9003, -9010, -9O1OTSP, -9010TTP, -9011, -9012, -9O12TSP, -901211P, and -9031C non-coded addressable manual pull stations. Models 4099-9001 and -9010 are single action stations. Models 4099-9002 and -9011 are breakglass stations. Models 4099-9003 and -9012 include a push bar which must be punched in before be Wig able to grab and pull down the actuating handle. Model 4099-9031C is a double action station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. Models are intended for use with listee's Models 4010, 4100,4100U and 4020 control units (CSFM Listing Nos. 7170-0026:226, 7165-0026:160 or 7170-0026:187, 7170-0026:250 or 7165-0026:251 and 7165-0026:178). Model 4099-9013C is intended for use with Model 4010 control unit only. For indoor use only. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Rev. 0 1-26-2001 ofm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed "\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions andlor other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division OSimplex lrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) UL listed to Standard 464 -7 i/ - .)! F IRE, 2 Wall and Ceiling Mount A/Vs Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559492; 5622427; 5865527; 5,886620; 6,281789; 6,954,137; 7005,971; and 7,006,003. S4906-0002-4 1212007 Firm rr tri Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." 4006, 4008,4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 lDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color FIRE Lettering Description 4906-9127 Red White 4906-9129 Wall White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 4906-9128 Red White 15, 30, 75, or 110 candela; operates with SmartSync two-wire Ceiling control 4906-9130 White Red Wall Mount A/V Accessories Model Description Dimensions - 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white "FIRE" lettering 5-1/8" H x 5" W x 1-1/2" D 4905-9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16"W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box Ceiling (216 mm 156 mm x 76 mm) 49059928* Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2' deep, (121 mm x 175 mm x 38 mm) 490579916 Red * UL listed by Space Age Electronics Inc. S4906-0002-4 12/2007 2 Removable cover (tool required) AN Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 DC; see Note I below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm" to 3.31 mm) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage Horn Output 16 VDC 24 VDC 33 VDC Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mou nt Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 103 mA 196 mA 253 mA 50 mA 77 mA 147 mA 190 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W x 2-5/8" D (121 mm x 175 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd 110 cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA 57 mA 88 mA 167 mA 213 mA NOTES: 1 "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a Sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting = - (J) -- Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; 15 factory setting is 15 cd Strobe intensity viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even With, or slightly r _,-Electrical above bottom\ r box outline of compatible X11L boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0002-4 12/2007 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others Optional 4905-9838 Sound Damper, field attached to attenuate sound 5 to 6 dBA Wiring access hole Wiring terminals for - 'N(D SmartSync operation 45 Box 4905-9931 Adapter Plate can be used on other mounting options) Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4(102mm) square box, surface mounted box 1-1/2 (38 mm) minimum depth Four mounting IIIIJI? - Ce'l'ng reference, flush mounted box Optional 4905-9915/-9916 Adapter, V recommended for surface mounted box - - - Optional 4905-9928 Adapter Plate, required for surface mounted electrical box ips included, two each side Wiring terminals are located behind the housing Optional 4905-9927 Red Wire Guard End View ----------------------------------- Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt - Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4"(102mm)square___.J 44 box profile, 1-1/2" f (38 mm) deep Optional 4905-9961 Wire Guard NV Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo, ID Net, TrueAlert, and SmartSync are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4906-0002-4 1212007 www.tycosafetyproducts-usa-wm.com 02007 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used With listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. NOTE: 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division G.SiMpIeX lrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTM Operation Compatible Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: UL listed to Standard 1971 Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: 4006, 4008, 4010, and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Secton 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Wall Mount Strobes Ceiling Mount Strobes Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. t'.l! (SI I1 I II(I I I1I'Z.1I [:iI1 L.J During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). ' Simplex multi-candela SmartSync two-wire horn/shobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7005,971; and 7,006,003. S4906-0001-3 5/2008 I7 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Mi11I Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). IiUTII.1!It.(*I Class B SmartSync two-wire control is available from: 4006, 4008, 410011.11, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Class A SmartSync two-wire control is available from 4100U NACs and from the 4905-9938 SCM. Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. [Product Selection Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color FIRE Lettering Description 4906-9101 Red White 4906-9103 Wall White Red Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate' 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D (136 mm x 133 mm x 41 mm) 4905-9940 White deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) 1 (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D -- (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model I Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8"x 3-1/8" x 0.060' D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm 2) wire leads rated for 2 A NAC, ,, - x 2-7/16" x 13/16 4905-9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8!'x 1-1/4" D 4" (102 mm) square box (102 min 105 mm 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering x 5-1/8" H 5" W x 1-1/" D 4905-9993 White cover with red "FIRE" lettering For Wall mount strobes (130 mm x 127 mm x 38 mm) 49059961* Wall mount 6-1/16" H x6-1/16"Wx3-1/8" 0 Red wire guard with mounting plate, compatible with (1154 mm x 154 mm x 79 mm) 49059926* Ceiling mount semi-flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8" deep (156 mmxlii mmx73mm) * UL listed by Space Age Electronics Inc. S4906-0001-3 5/2008 16-Ifne TV Me- Wall Mount or Ceiling Mount, Common Specifications UL Listed Rating Rated Voltage Range ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 ni' Housing Dimensions (with lens) 4-3/4' Lx 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA I 281 mA 50 mA 8 3 mA 155 mA 211 mA NOTES: 'Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting ( LTh cjTh (jTh/ Mounting is compatible with ( ( \jjf single gang, double gang, and ________________________ ______ 4" (102 mm) square boxes, o 1-1/2" (38 mm) deep, by others ________________________ _________ Wiring access hole - Ti oo Wiring terminals - o Mounting Holes: 4 square (4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection plug, accessible only ' r n 0 from rear of housing; factory setting is 15 cd 15 [j Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANTI WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even :xJ ,box —Electrical with, or slightly of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0001-3 5/2908 4905-9931 Adapter Plate 4905-9931 Adapter Plate nal Wire Guard - reference only, can be used on other mounting options) Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V5744S) 2-1/4 (57 mm) I deep, supplied by others Handy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2' (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) CD 0 0 1" 4905-9910 Adapter Plate, required for - - surface mount with handy box unless using the 4905-9926 wire guard Ceiling mount strobe Optional 4905-9926 wire guard with mounting plate viewing slot / I Intensity selection plug, / : b accessible only from rear of lens: L housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4"(102mm)square-.-_J box profile,1-1/2' I[P -- (38 mm) deep Optional 4905-9961 Wire Guard - Strobe L ---- Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSyac are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). BmSirnplex Tyco Safety Products Westminster• Westminster, MA • 01441-0001 USA S4906-0001-3 5/2008 www.tycosafetyproducts-usa-wm.com 02008 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VOC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division