Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5781 VAN ALLEN WAY; ; FA120037; Permit
4/4/25, 3:05 PM FA120037 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 5781 VAN ALLEN WY Permit Type: FALARM Parcel No: 2121304400 Lot #: 0 Reference No.: PC #: Project Title: LIFE TECHN-AREA 12, 4,6 T.I. Permit No: FA120037 Status: APPROVED Applied 9/17/2012 Approved: 9/17/2012 Issued: 9/17/2012 Inspector: Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: THE G C NET LEASE (CARLSBAD) INVESTORS L L C C/O LIFE TECHNOLOGIES CORP 1600 FARADAY AVE CARLSBAD CA Fees ($) Total ($) Balance 364 0 364 0 about:blank 1/1 - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up, to 14% cost of installation** Sleek Modern Aesthetics 4Y A Finger Slide Switches Voltage Test Points Multiple Voltages 2h4 3 Audible Settings 90, 95, 99 dB 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 ) Universal Mounting Base " CFJ Ceiling and Wall Mounts to 5 Backbox Types - •1 COOPER Notification Strobe, Horn Strobe, and Horn Notification Appliances Ceiling I Wall Description: The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefitfrom its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock5 ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock5 Excederrm Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol - Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the Regulated Voltage range * Compared to competitive models Patented Compared to previous models HornRatings per UL Anechoic - - Model Regulated Voltage Range VDC 99 dB 95 dB 90dB FIN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 / 4 3) NOTE: All CAUTIONS and WARNINGS are identified by the symbol k All warnings are printed in bold capital letters. AL WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°(-- to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 .• .• ..•.. 24VDC 0.197 0.242 0.282 1 .• 10.125 .• 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 •• •. •_••.••.• 24VDC 0.186 0.230 0.272 10.122 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Strobe OSM or Mounting Model 12/24 VDC* Candela Wheelock Power Options Supplies HSR 1511575130/75/95/llO/1351185 X X UMB** UMB** HSW 15/1575/30/75/95/110/135/185 X X HSRC HSWC 1513016017519511151151J1177 X X UMB** 15130/60/75195/115/150/177 X X UMB** STIR , 15/1575/30/75/95/110/135/185 X X UMB** 15/1575130/75/951110/135/185 X X UMB** '"' STW ST 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB HNW X X • UMB** HNRC X X UMB** X UMB - I-INWC X NOTE Due to continuous development of our products specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc dba Cooper Notification standard terms and conditions Architects and Engineers Specifications The notification appliances shall be Wheelock" ExcederT" Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have B field selectable settings at 15, 15175, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Member__________ WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6111 Wheelock' [WW SAFEPATH" WAVES-IT Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEW1IT, Deputy State Fire Marshal Fire Engineering Division Notification Strobe, Horn Strobe, and Horn Notification Appliances Ceiling Description: The WheelockO ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheeloce ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock5 ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to models now in I appliance Save up to 14% cost of installation" goo Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB €A 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75!95/115/150/177 I Universal Mounting Base Ceiling and Wall O Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Compatible with UL Regulated Voltage using filtered VDC or unfiltered VRMS Input voltage Strobes produce 1 flash per second over the Regulated Voltage range Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their 'Regulated Voltage Range. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (12%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 0.14.8 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.176 0.197 1 0.242 0.282 10.125 .. ... .. ....... 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 24VDC 0.122 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 HornRatings per UL Anechoic - - Model Regulated Voltage Range VDC 99dB 95dB 90dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 1 0.026 1 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Strobe DSM or Mounting Model 12/24 VDC Candela Wheelock Power Options Supplies HSR X 15/1575/30175/951110/135/185 X UMB** HSW HSRC HSWC 15/1575/30/75/95/110/135/185 X X UMB** UMB** 151301601751951115/1501177 X X 15/30/60/75/95/115/150/177 X X . UMB** o o STR STW ' 15/1575/30175/95/110/135/185 X X UMB** 15/1575/30/75/95/110/135/185 X X UMB** X X S. STWC 15/30160175195/1151150/177 15/30/60/75/95/115/150/177 X X UMB** UMB** I:I.]da X X UMB** HNR HNW X X UMB** HNRC X X UMB** X UMB* - HNWC X NOTE Due to continuous development of our products specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Notification Wheelock' (MEDCJ SAFEPATH WAV * Architects and Engineers Specifications The notification appliances shall be Wheelock' Exceder' Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15175, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" Wx 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and SIC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, WheeIock Power Supplies or other manufacturer's panels with built-in Wheelock' Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6111 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional 'S' for silver fascia may be added. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWIIT, Deputy State Fire Marshal Fire Engineering Division Notification Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 8 Candela Settings Wall - 15/1575/30175/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 N Universal Mounting Base O Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Strobe, Horn Strobe, and Horn Notification Appliances EL Ceiling E1 Description: The Wheeloce ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock ExcederTM Series incorporates high reliability and high efficiency opticsto minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock5 ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. -,Save up to 48% in current draw* - Up to 9 models now in 1 appliance Save up to i4% cost of installation** ~0;4 Sleek Modern Aesthetics Finger Slide Switches Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock" Patented Sync Protocol Compatible with UL Regulated Voltage" using filtered VDC or unfiltered VRMS Input voltage Strobes produce 1 flash per second over the Regulated Voltage range * Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. 4 WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971.. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 24VDC 0.125 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 - 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 i 0.230 0.272 .............. 24VDC 0.122 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 HornRatings per UL Anechoic - - - Model Regulated Voltage Range VDC 99 d13 95dB 90dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies Iiflh1I1T1.i* HSR 15/1575/30/75/95/110/135/185 X X HSW 15/1575/30/75/95/110/135/185 X X UMB** HSRC 15130160175195/11511501177 X X UMB** HSWC 15/30/60/75/95/115/150/177 X X UMB** o o STIR 15/1575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/951115/150/177 15/30/60/75/95/115/150/177 X X X X UMB** UMB** t--tl X X UMB* X X UMB** HN X X UMB** HNWC X UMB X NOTE Due to continuous development of our products specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc dba Cooper Notification standard terms and conditions Wheelock° (MEDCJ SAFEPATIr WAV) Notification Architects and Engineers Specifications The notification appliances shall be Wheelock' ExcederT Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a C may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional S' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division :Integrated Security Fire Alarm Record of Completion 8806UE00 Date: I 0/03//2., Customer#:.35 0 7 Job #: Primary System #:HOO &O Secondary System #:_________________ Customer Name: L / e. 7e c ,, L 0 ,31 e Address(City/State/ZII)5 ( VAJ,1L,&A' C# 2.c CM 2 Representative of Protected Property (Name/Phone): Authority Having Jurisdiction: ,t I ' e, e 0844 e7—Telephone #: Location of As-Built Drawings: 13 Location of Operation and Maintenance Manuals: O i'>I . C-- Location of Inspection & Testing Reports: Location of Control Panel: QL4 Primary Telephone #: Secondary Telephone #: Does Tyco have a contract for testing and inspection in accordance with NFPA standard(s)? fl Yes El NO If no. who?: Inspection Start Date: Inspection Frequency: 0 Annually 0 Semiannually 0 Quarterly 0 Bimonthly 0 Monthly 0 Weekly System Software Operating system (executive) software revision level(s): (b) Site-specific software revision date: Revision completed by (Name) (Company) (Date) Type(s) of System or Service O NFPA 72, Chapter 8—Tyco Central Monitoring Center ' Means of transmitting signals from the premises to the central station: (Check all that apply) ,(,pjgital Alarm Communicator 0 McCulloh 0 Multiplex 0 One-way Radio 0 Two-way Radio 0 Other. Means of transmission of alarms to the public fire service communications center: ,4/l6"c ,_, .. .•,., System locations: El NFPA 72, Chapter 6- Local If alarm is transmitted to location(s) off premises, list where received: # P 721 Chapter 8- Remote Statior Telephone numbers of the organization receiving alarms: O NFPA72, Chapter 8- Proprietary Telephone numbers of the organization.receiving alarm: 0 NFPA 72, Chapter 9-Auxiliary Check type of connection: 0 Local Energy 0 Shunt 0 Parallel Telephone Telephone numbers of the organizatioh receiving alarm: If alarms are retransmitted to a public fire service communications center or other, indicate name and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: Record of System Installation - (Complete this section after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by /1 '/01('e.k.,.ro -, on / 0 16 1 //.z, , includes the devices shown in sections 4 & 5, and has been in service since This system has been installed in accordance with the standards as shown below: NFPA72.Chapters 1 .2 0..3 ..4 ...5 ,,- 6 ,,-7 18 10 0 11 (Check all that apply) FPA 70, National Electrical Code, Article 760 J ,. Manufacturer's Instructions Reprinted with permission from NFPA 72 ® 2002, National Fire Alarm Code®, Copyright © 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only, by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (06/12)' (p. 1 of 3) / Customer , . "... #.. r '. . . £ •.& 'si.. ,.I'. . ' P' ".., ' 'l cI - ' Integrated Security cJ:t:_)3;;' c III II IH 11111101 HIII 011IIH 1111 ll Fire Alarm Record of Completion, cont. 8806UE00 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features al-id functions of thii sVsternee testedby r.,7ji/iv 1!4J'p,, date /0 /O. 1/2. And found to be operating properly in accordance with the requirements of: tFPA 72, Chapters J2k2 0...3 (4 M5 , 6 ,I 7 ,~1 9 ..10 0 11 (Check all that apply) FPA 70, National Electrical Code, Article 760 0 Manufacturer's.litructtons AHJ or Other Source:. , tJ )(.Signed: , ,Xpate: / )<..Organization: L ?f' "to 4y- 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity Style Class 5. Alarm-Initiating Devices and Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity I Style .!/ Class Manual — - Manual stations . Non-coded Coded Transmitters - Addressable Combination manual fire alarm and guard's'tour coded statins Automatic - Coverage: (Check all that apply) 0 Complete 0. Partial '. 0 Selective 0 Non-required Enter quantities and check if the devices are addressable.' - Smoke detectors Ion Photo 0 Addressable Duct detectors '. Ion Photo , 0 Addressable Heat detectors FT RR FT/RR RC 0 Addressable Sprinkler waterfiow indicators: Non-coded Coded Transmitters 0 Add4ssabIe The alarm verification feature is 0 Disabled 0 Enabled , changed from seconds to, seconds.- Other (list): 6. Supervisory Signal-Initiating Devices and Circuits Guards Tour: 0 (a) Coded stations 0 (b) Non-coded stations 0 (c) Compulsory guard's tour system comprised1of transmitter stations and intermediate stations. Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. (Check if provided;) / Sprinkler System: Electric fire pump: Electric-driven fire pump: Electric-driven generator: o (a) Valve supervisory switches 0 (e) Fire pump power " 0 (h) Selector in auto position 0 (k) Selector in auto position El (b) Building temperature points (f) Fire pump running 0 (i) Engine dr control panel trouble 0 (I) Control panel trouble Site water temperature points (g) Phase reversal 0 (j) Fire pump running 0 (m) Transfer switches Site water supply level points C] (n) Engine running 0 Other supervisory function(s) (specify): Reprinted with permission from NFPA 72 ® 2002, National IRre Alarm Code®, Copyright© 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (6/12) (p. 2 of 3) - Customer 1w Integrated Security IIMI i lili 1111 MIII IIH IID lID II Fire Alarm Record of Completion, cont. 8806UE00 7. Annunciator(s) Quantity: Type: Location(s): 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency Voice/Alarm Service Quantity of voice alarm/alarm channels:: Single: Quantity of speakers: Quantity of speakers zones: Quantity of telephones or telephone jacks attached to the system: — Types and quantities of notification appliances installed: Bells With Visible: Speakers With Visible: (C) Horns X 9 With Visible: ) / 9. System Power Supplies Fire Alarm Control Panel: ' Nominal voltage: Overcurrent prótection: Type: Location: I Secondary (standby): , ' Storage battery: Amp-hour rating: Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply: - Emergency system described in NFPA 70, Article 700 Multiple: Chimes With Visible: Other: With Visible: Visible appliances without audible: Current rating Current rating - .,. . Calculated capacity to drive system, in hours: (24) 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: Customer Comments: Customer Name: (—) g.j C. c( ç Signature: 7, Print Name Date ' Tyco Representative Name /'/ Signature: Print Name Date Upon completion of theSIem(s)satisfactortest(s) witnessed (if required by the Authority Having Jurisdiction): AAHJ Represent: _ /3j' ignature:L2.) O Print ._,) ate /"zritle: _i,. , Telephone #: kN Reprinted with permissiontrm NFPA 72 @2002, National Fire Alarm Code®, Copyright© 2002, National Fire Protection Association, Quincy, MA 02169. This reprinted, material is not the complete and official position of the NFPA on the refere)iced subject, which is represented only by the standard in its entirety. @2012 Tyco Integrated Security. All rights reserved. (Q6/12) (p. 3 of 3) Customer