HomeMy WebLinkAbout3465 TRAILBLAZER WAY; ; FA150049; Permit4/4/25,3:13 PM FA150049 Permit Data City of Carlsbad Fire Alarm Permit 3465 TRAILBLAZER Job Address: WY Permit Type: FALARM Parcel No: 2080104200 Lot #: 0 Reference No.: Permit No: FA150049 Status: APPROVED Applied 7/30/2015 Approved: 8/4/2015 Issued: 8/4/2015 PC #: Inspector: Project Title: FIRE STATION 3 INSTALL A NEW ADDRESSABLE FIRE ALARM SYSTEM; HVAC UNITS TO BE WIRED FOR GLOBAL SHUTDOWN BY HVAC CONTRACTOR; CELLULAR COMMUNICATIONS MEETS NFPA 72 STANDARDS FOR SINGLE PATH COMMUNICATION. COMPLY WITH ALL BUILDING AND FIRE ALARM CODES REFERENCED IN EFFECT AT TIME OF SUBMITTAL. Applicant: JMG SECURITY 17150 NEWHOPE SUITE 109 800-900-4564 Owner: CITY OF CARLSBAD PUBLIC AGENCY Fees Add'I Fees Total r Balance 478 0 I 478 I 0 about:blank 1/1 USE AND OCCUPANCY CLASSIFICATION Boarding houses (transient) with more than 10 occupants Congregate residents (transient) with more than 10 occupants Hotels (transient) Motels (transient) [HCD 1] Efficiency dwelling units (transient) 310.4 Residential Group R-2. Residential occupancies con- taining sleeping units or more than two dwelling units where the occupants are primarily permanent in nature, including Apartment houses Boarding houses (nontransient) with more than 16 occupants Congregate residences (nontransient) with more than 16 occupants Convents Dormitories Fraternities and sororities Hotels (nontransient) Live/work units Monasteries Motels (nontransient) Vacation timeshare properties [HCD 1] Efficiency dwelling units (nontransient) 310.4.1 Residential Group R-2.1 This occupancy shall include buildings, structures or parts thereof housing cli- ents, on a 24-hour basis, who because of age, mental dis- ability or other reasons, live in a supervised residential environment that provides personal care services. This occupancy may contain more than six nonambula- tory and/or bedridden clients. (See Section 425 Special Provisions for Licensed 24-Hour Care Facilities in a Group R-2. 1, R-3.1 or R-4 Occupancy). This group shall include, but not be limited to, the following: Assisted living facilities such as: Residential care facilities, Residential care facilities for the elderly, (RCFEs), Adult residential facilities, Congregate living health facilities, Group homes, Residential care facilities for the chronically ill, Congregate living health facilities for the terminally ill. Social rehabilitation facilities such as. Halfway houses, Community correctional centers, Community correction reentry centers, Community treatment programs, Work furlough programs, Alcoholism or drug abuse recovery or treatment facilities. 310.5 Residential Group R-3. Residential occupancies where the occupants are primarily permanent in nature and not classified as Group R-1, R-2, R-2.1, R-3.I, R-4 or I, including: Buildings that do not contain more than two dwelling units Boarding houses (nontransient) with 16 or fewer occupants Boarding houses (transient) with 10 or fewer occupants Adult care facilities that provide accommodations for six or fewer clients of any age for less than 24 hours. Licens- ing categories that may use this classification include, but are not limited to: Adult Day Programs. Child care facilities that provide accommodations for six or fewer clients of any age for less than 24 hours. Licensing categories that may use this classification include, but are not limited to.. Day-Care Center for Mildly Ill Children, Infant Care Center, School Age Child Day-Care Center. Congregate residences (nontransient) with 16 or fewer occupants Congregate residences (transient) with 10 or fewer occupants [HCD 11 Efficiency dwelling units Family Day-Care Homes that provide accommodations for 14 or fewer children, in the provider's own home for less than 24-hours. Alcoholism or drug abuse recovery homes (ambulatory only) Foster family homes (ambulatory only) Adult care and child care facilities that are within a single family home are permitted to comply with the California Residential Code. 310.5.1 Residential Group R-3.1 This occupancy group may include facilities licensed by a governmental agency for a residentially based 24-hour care facility providing accommodations for six or fewer clients of any age. Cli- ents may be classified as ambulatory, nonambulatory or bedridden. A Group R-3.1 occupancy shall meet the requirements for construction as defined for Group R-3, except as otherwise provided for in Section 425 Special Provisions For Licensed 24-Hour Care Facilities in a Group R-2. 1, R-3. I or R-4 Occupancy. This group may include: Adult residential facilities Congregate living health facilities Foster family homes Group homes Intermediate care facilities for the developmentally disabled habilitative Intermediate care facilities for the developmentally disabled nursing Nurseries for the full-time care of children under the age of six, but not including "infants" as defined in Section 310 Residential care facilities for the elderly Small family homes and residential care facilities for the chronically ill Exception: Group Homes licensed by the Department of Social Services which provide nonmedical board, room and care for six or fewer ambulatory children or 100 2013 CALIFORNIA BUILDING CODE FIRE PROTECTION SYSTEMS Manual fire alarm boxes are not required throughout the building when the following conditions are met: 2.1. The building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2; 2.2. The notification appliances will activate upon sprinkler water flow; and 2.3. At least one manual fire alarm box is installed at an approved location. 907.2.8.2 Automatic smoke detection system. An automatic smoke detection system that activates the occupant notification system in accordance with Sec- tion 907.5 shall be installed throughout all interior cor- ridors serving sleeping units. Exception: An automatic smoke detection system is not required in buildings that do not have interior corridors serving sleeping units and where each sleeping unit has a means of egress door opening directly to an exit or to an exterior exit access that leads directly to an exit. 907.2.8.3 Smoke alarms. Single- and multiple-station smoke alarms shall be installed in accordance with Sec- 907.2.9 Group R-2 and R-2.1. Fire alarm systems and smoke alarms shall be installed in Group R-2 occupancies as re 'uired in Sections 907.2.9.1 and 907.2.9.3. 907.2.9.1 Manual fire alarm system. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group R-2 occupancies where: Any dwelling unit or sleeping unit is located three or more stories above the lowest level of exit discharge; Any dwelling unit or sleeping unit is located more than one story below the highest level of exit discharge of exits serving the dwelling unit or sleeping unit; or The building contains more than 16 dwelling units or sleeping units. Congregate residences with more than 16 occu- pants. Exceptions: A fire alarm system is not required in build- ings not more than two stories in height where all dwelling units or sleeping units and contig- uous attic and crawl spaces are separated from each other and public or common areas by at least 1-hour fire partitions and each dwelling unit or sleeping unit has an exit directly to a public way, egress court or yard. Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and the occupant notification appli- ances will automatically activate throughout the notification zones upon a sprinkler water flow. A fire alarm system is not required in build- ings that do not have interior corridors serving dwelling units and are protected by an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, provided that dwelling units either have a means of egress door opening directly to an exterior exit access that leads directly to the exits or are served by open-ended corri- dors designed in accordance with Section 907.2.9.2 Smoke alarms. Single- and multiple-station smoke alarms shall be installed in accordance with Sec- ti 907.2.9.3 Group R-2 college and university build- ings. An automatic smoke detection system that acti- vates the occupant notification system in accordance with Section 907.5 shall be installed in Group R-2 col- lege and university buildings in the following locations: I. Common spaces outside of dwelling units and sleeping units. Laundry rooms, mechanical equipment rooms, and storage rooms. All interior corridors serving sleeping units or dwelling units. Required smoke alarms in dwelling units and sleep- ing units in Group R-2 college and university buildings shall be interconnected with the fire alarm system in accordance with NFPA 72. Exception: An automatic smoke detection system is not required in buildings that do not have interior corridors serving sleeping units or dwelling units and where each sleeping unit or dwelling unit either has a means of egress door opening directly to an exterior exit access that leads directly to an exit or a means of egress door opening directly to an exit. 907.2.9.4 Licensed Group R-2.1 occupancies. Licensed Group R-2.1 occupancies housing more than six nonambulatory, elderly clients shall be provided with an approved manual and automatic fire alarm sys- tem. Exceptions: Buildings housing nonambulatory cli- ents on the first story only and which are protected throughout by the following: 1. An approved and supervised automatic sprin- kler system, as specified in Sections 903.3.1.1 2013 CALIFORNIA FIRE CODE 163 FIRE PROTECTION SYSTEMS or 903.3.1.2, which upon activation will initi- ate the fire alarm system to notify all occu- pants. A manualfire alarm system. Smoke alarms required by Section 907.2.1 1. 907.2.10 Group R.4. Fire alarm systems and smoke alarms shall be installed in Group R-4 occupancies as required in Sections 907.2.10.1 through 907.2.10.3. 907.2.10.1 Manual fire alarm system. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group R-4 occupancies. Exceptions: A manual fire alarm system is not required in buildings not more than two stories in height where all individual sleeping units and contig- uous attic and crawl spaces to those units are separated from each other and public or com- mon areas by at least I-hour fire partitions and each individual sleeping unit has an exit directly to a public way, egress court or yard. Manual fire alarm boxes are not required throughout the building when the following conditions are met: 2.1. The building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2; 2.2. The notification appliances will acti- vate upon sprinkler water flow; and 2.3. At least one manual fire alarm box is installed at an approved location. Manual fire alarm boxes in resident or patient sleeping areas shall not be required at exits where located at all nurses' control stations or other constantly attended staff locations, pro- vided such stations are visible and continu- ously accessible and that travel distances required in Section 907.4.2.1 are not exceeded. 907.2.10.2 Automatic smoke detection system. An automatic smoke detection system that activates the occupant notification system in accordance with Sec- tion 907.5 shall be installed in corridors, waiting areas open to corridors and habitable spaces other than sleep- ing units and kitchens. Exceptions: Smoke detection in habitable spaces is not required where the facility is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1. I. An automatic smoke detection system is not required in buildings that do not have interior corridors serving sleeping units and where each sleeping unit has a means of egress door opening directly to an exit or to an exterior exit access that leads directly to an exit. 907.2.10.3 Smoke alarms. Single- and multiple-station smoke alarms shall be installed in accordance with Sec- tion 907.2.11. 907.2.11 Single- and multiple-station smoke alarms. Listed single- and multiple-station smoke alarms comply- ing with UL 217 shall be installed in accordance with Sec- tions 907.2.11.1 through 907.2.11.4 and NFPA 72. Exception: For Group R occupancies. Afire alarm sys- tem with smoke detectors located in accordance with this section may be installed in lieu of smoke alarms. Upon actuation of the detector, only those notification appliances in the dwelling unit or guest room where the detector is actuated shall activate. 907.2.11.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1: I. In sleeping areas. In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit. In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. See Section 907.2.11.5 for specific location 907.2.11.2 Groups R-2, R-2.1, R-3, R-3.1 and R-4. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-2.1, R-3, R- 3.1 and R-4 regardless of occupant load at all of the fol- lowing locations: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bed- rooms. 2. In each room used for Exception: Single- or multiple-station smoke alarms in Group I-I shall not be required where smoke detectors are provided in the sleeping rooms as part of an automatic smoke detection system. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 164 2013 CALIFORNIA FIRE CODE Submittal Package for: Carlsbad Fire Station No. 3 3465 Trail Blazer Way Carlsbad, CA 92008 - JMG Security Systems, Inc. 17150 Newhope Street, #109 Fountain Valley, CA 92708 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Cellular Communicator Smoke Detector Heat Detector Manual Pull Station Input Module CO Detector Duct Smoke Detector Strobe Thcic has c been vicwd lot anpal eat c II ipliai)Cs pIaIU Ho/Strobe im Ue ciIrenl applicable codes md .timdti ds it loire 'm)IIt) liii Weatherproof Horn iii 1mm in) t mn. l)r is' )I' I11 this testes' a n1mpoI'i ot an cailolt for ,l hmIddnI mets): be 1)1 irstiiidtng Illil ibis in' in') 1) C UI) i'tmctoC mt their 1)0 \\ as CI tm C5 mISC 00'I)CF prCi0I) ci151i)CCF ui am'chmteit lilt' sole mespoimibil)i> codes and standards ltr 1)111 coinplt 'tee with said trcluditm the bitildtttg code or 1mr ann e5pommsihilty In' dehctcflC' en'ots, oiiiis5iOIt or imenligeimce in these S whetiler or tot noted in this review. I tate: )NIMENI) API'R( )VAI rvi KE, ONlimlhNl) At'I'ht )'s'\l., AS Nit lIt) DPG 12/23/2014 0 FA150040 Model 5808 lntelliKnight® 5808 Single Loop Addressable Fire Alarm Control System The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. lntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Built-in synchronization for 5808 performs-drift compensation and appliances from AMSECO, Gentex®, calibration checks on each of the Faraday, System Sensor®, and sensors in the system. Wheelock® One Form C trouble relay rated at The basic 5808 system can be 2.5A at 27.4 VDC and two Form C enhanced by adding modules such as programmable relays rated at 2.5A at 5860 remote annunciator, 5824 27.4 VDC serial/parallel printer interface module Programmable date setting for (for printing system reports), and 5496 Daylight Saving Time Plex-2 door option combines a dead intelligent power module. 5808 also front cabinet door with a clear features a powerful built-in dual line fire window, limiting access to the panel communicator that allows for reporting while providing single button of all system activity to a remote operation of the reset and silence monitoring location. functions Features Electrical Specifications Up to 127 addressable points Primary AC: 120 VRMS at 50/60 Hz, Up to 125 zones and 125 output 2.75A groups Total Accessory Load: 6A @ 27.4 VDC Uses standard wire—no shielded or twisted pair required Notification Power: 6A @ 27.4 VDC, Built-in digital communicator power-limited Central station reporting by point or Standby Current: 170 mA by zone Supports Class B (Style 4) and Class Alarm Current: 325 mA A (Style 6 or 7) configuration for SLC Notification & Auxiliary Circuits: Distributed, intelligent power 3A @ 27.4 VDC per circuit, Drift compensation power-limited 13 pre-programmed output cadences, (including ANSI-3.41), and 4 Battery Charging Capacity: 7.0-35.0 AH programmable outputs Battery Size: 18 A max. allowed in Notification circuits can be configured FACP. Larger capacity batteries can be as 2 Class A (Style Z) 0r4 Class B housed in an RBB accessory cabinet (Style Y), or auxiliary power for resettable, constant, or door holder Mechanical Specifications power Built-in annunciator with 80-charáctër 'Flush Mount Dimensions: LCD display 14.5" W x 24.75" H x 3.5" D RS-485 bus provides communication (36.8 W x 62.9 H x 8.73 D cm) to system accessories Overall Dimensions: Built-in RS-232 and USB interface for 16" W x 26.4' H x 4.65" D programming via a PC Upload or download programming, (40.6W x 67 H x 11.8 D cm) event history, or detector status via Weight: 28 lbs. (12.8 kg) remote or direct connection Color: Red Improvements in SKSS deliver five times faster upload/downloads Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ3IX (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 142; MEA 429-92-E Vol. XIV DSILENT KNIGHT by Honeywell I I I SO$.AlM $DK41O OM CS&fl SQSOSAJ$ W.5aI' I rss SD.* tOdtj.,fl4 DSt,.AhM UJ 41 "'•""114 1-- 5496 SLC Detectors SD505-APS Addressable photoelectric smoke detector. S0505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F-1 50°F(0°C-37°C). SD505-6AB Six inch base for use with detector heads SD505-APS, SD505-AIS and SD505-AHS. SD 50 5-4AB Four inch base for use with detector heads SD505-APS, S0505-AIS, and SD505-AHS. S0505-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61B Short circuit isolator base for SD505-APS, SD505-AlS, and SD505-AHS detectors. SD505-6RB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-ADH Duct housing that detects smoke in HVAC ducts. SD505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and 50505-AlS sensors. Compatible with 50505-DTS remote test switch. SD500-PS/SD500-PSDA SDSOO-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules Model SD500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500-MIM Mini dry contact input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SD500-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500-SDM Two-wire detector input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LlM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500-LEDs can be used per system. S-BUS Accessories 58601R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5808. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. .4 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Miscellaneous Accessories 5660 Silent Knight Software Suite PC-base software for FACP programming. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-2 Door Dead front cabinet door with clear window to limit access to the FACP. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"W x 10" H x 6"D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-ADHR. D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA FORM# 350386 Rev. D 04/06 Copyright © 2006 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM -. LISTING SERVICE LISTING No. 7165-0559:0142 Page 1012 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models *5808 *lFp100 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5808, IFP-100 Control Units *01 FP-1 OOBD Motherboard 7628 EOL Resistor 5860/5860R1RA-1000 Annunciator *OlFP100lA lFP-100 User Interface *058631 5808 User Interface 5496 Power Module 5824 Serial/Parallel Interface RPS-1000 Power Expander/Supply 5865-3/5965-4 LED Annunciator 5880 LED 10 Module 5883 Relay Interface Board SD500-ANM Addressable Notification Module SD500-LlM Line Isolation Module SD505-61B Isolation Base SD-500 SDM Smoke Detector Module RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module *122740 *122723E Enclosures RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct i" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division .0 Listing No. 7165-0559:0142 Page 2 of 2 This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 2. 4 - Wii :TG7-FS NJFZ-ArtOiRt - N.E - - - 4. OF 4 t734 V 1711 &PRODUCTFEATUR9 Meets UL 864 require rs :rMCIU pa S.,: - .,communications.,, yP. 4 u 41. 4Provides RMR protection by leveraging technology that operates J o3G/4Gnetworks 4. ) •.• &ts listen-in, two 41 V 11 ~. :.. ~ ;... N, x e W4'I. 4inimizes false alarms byproyiding dual paths for self tests 4 ' I Falls back to 2G (GSM) if 'a 3G/4G network isn't available - 4:.: The. Telguard TG-7FS is the ideal-cellular alarm communications solution' for commercial fire systems. The TG-7FS transmits alar.m signals from P Ak the fire -panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as -the sole communications path for the fire alarm system: It replaces all of the landlines currently dedicated to the master control unit. On average cellular monitoring cotstheend user significantly lessthan a dedicated landline. For eachiandline replaced With a-TG-7FS, the -. 'monthly communications bitt decreases By being able to signal failures to the central station within sixty _____ minutes of an outage the TG 7FS can be installed as the sole path for _____ ' commercial fire installations For existing installtioris all landlines car' be swapped for a single TG 7FS because of the new sixty minute - -.. -• Tsupèvisionmode. - • • - - - • - -- - - The-TG-7FS can-also be1nstalIèdaa backup path and ugraded tosolj - patht a later date -'-4w - - - ->. - - . -•. •-- •: - :4 .3.j••'.n' TELGUARD, • 1' IN 11 1kTI. FOR3Gi4GNETWC 4 fr a ç -fr-k 8 iv 5 3 ..................-:.- 4 a, v vfj a I- c5 n* 4 4 isa:fiiv , [telguard technology allows full data reporting for unlimite '- d' point-to-point signal details and maximum transmitting powrH superior in building penetration 0. Telguard products are easy to install economical and UL Listed ' Accessories 33.3 ,ac•.. ACD 12, ACID 35, ACID 50, ACID 100 r e 12/35/50/100 feet of low loss, high performance cable. HGD 0 High gain directional antenna EXD 0 External antenna . -• - 'r... ...... - - - - - - - - "UL Listings — 3 Commercial Fire Commercial Burglary Residential , 864 control units & 365 Police Station 985 Household fire accessories-for fire connected burglar warning systei7$ d - - alarm systems alarm units and *-3 — systems - '—i- il- 1610 Central station burglat - — alarm units —fiM L-ine security servcies I 0. For the most current product specifications and ULListings,visft wwwTeiguard corn 1 17 $ fu4; if lip l LEC ON AiOOATiON. r i W_ NF PA /Il\ Executive Strategic Partner LISTED-- . IN1ERMATIOf(AL 'v-p Gold v',--?-- II l fry v C - - -Telguard, a Division of Teiular corporatior4cUmberrth1d CenteI,.,3225 CumberiandBlvdSuite 300 --Atlanta GA 3033 - 800-229-2326,Option 5wwwTeiàrim Copyright ©2012 Telular CorporatiorAll Rights Reserved 4. AID .N.. • CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES LISTEE: TELULAR C0RP2727 Paces Ferry Rd., Ste. 1-800, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household apploication and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD5056AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RE/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog I Addressable Photoelectric Type an electronic signal. Under normal conditions, the status LED blinks Smoke Detector approximately every 15 seconds, The SD505-APS is particularly indicating that the head is suited to detecting dense smoke communicating with the loop. The / typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: 5D505-6AB (Sold Separately) (6" Base) 5D505-4AB (4" Base) D SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY A Model SD505-APS Addressable Photoelectric Type iVYfrj} 1 Smoke Detector k;c/h kI , Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight 5D505-AIS Ionization Smoke Detector, or 5D505- AHS Heat Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 4 Diameler= 5-15/16' Diameter = 3-15/16" 10 Height = 2 inches, including base siuorr XN1CHT Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev c,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0129 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURlTY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model 5D505-APS analog addressable photoelectric type smoke detector with model 5D505-4AB and 5D505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:0149 *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct HV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Addressable Heat Detector L~i~ lntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. lntelliKnight heat detectors are an essential component in virtually any lntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other lntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. _ILat..... ±L._ ivioaeu bUUb-MM ii we teuiperature exceeus me trip temperature Addressable Heat an alarm occurs. The status LED point (programmed at the panel), Detector lights continuously during the alarm The SD505-AHS is a heat detector period. suited to virtually any commercial Under normal conditions, the status setting. The SD505-AHS is an LED blinks approximately every 15 absolute temperature device. This seconds, indicating that the head is means that it responds in alarm if communicating with the loop. the temperature goes above the trip point (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the lntelliKnight panel. Features Low profile, 2 inches, including base Absolute temperature device Simple and reliable addressing Uses digital communication protocol The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. CFSM listed MEA listed FM approved SD505-AHS Heat Detector Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150°F (57°C TO 65°C) Ambient Temperature: 32F to 120°F (02C to 49C) Mounting: 4° SQR, 4° OCT Single gang mud ring Rated spacing: 70' between conenre on smooth ceilings. SILENT Compatible Bases: SD505-6AB KNIGHT D (6" Separately) (6" Base) SD505-4AB (4" Base) by Honeywell INTELLIKNIGHT ACCESSORY Model SD505-AHS L~~d Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knights lntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent 5D505-APS Photoelectric Smoke Detector, or 5D505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transjent suppression techniques shall be employed to minimize false alarm potential Diameter= 5-15116 Diameter = 3.15/16' 14 01 /1 / .1 I I / / SIu\T / K.NI(.I IT; / / /_\ \ ;( / / \\ \ L Height = 2 inches :i including base /'. , ..Y / .- 7 / Model SD505-6AB Detector Base Model SD505-AHS Detector Head (Front View) (Front View) D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA vTT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350229 Rev B,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALSLISTING PROGRAM LISTING SERVICE LISTING No. 7270-0559:0127 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model 5D505-AHS electronic fixed temperature heat detector (analog) with Models 5D505-4AB and 5D505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 39.5 VDC Temperature Range: 134oF - 149oF INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-0410:0147 *Rev. 06-12-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SD500-PS and SD500PSDA Addressable Pull-Station lntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knights lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & Extremely easy to operate S D500- DA Corrosion-resistant gold-plated Addressable Pull contacts. Reflective label makes it easier Station to locate in low light I The SD500-PS is a single action Operation I addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the I SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an lntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset A : explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same I PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32°F to 120°F UL Listed communicating with the loop. The (0°C to 49°C) CSFM listed status LED lights continuously Mounting: Single gang ADA compliant box - during an alarm. A dip switch on Optional Red Surface Mount Box PS-SMBB the addressable module is used to Key reset (Same key as Silent set the unique address. Knight enclosures) Specifications Surface mount back box available Operating Voltage: 24VDC '' SILENT Terminals - accept up to 14 Standby Current: .55mA Alarm Current: .55mA KNIGHT gauge wire SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. 'S S. .5 .5 S. 'S 'S Mounting to Single Gang Electrical Box rS:-v1 'S - 5* i. '5 1 "S 0 S.. .5.. 5S 5* '5 '5 'S 'S 5. 5,. 5, '5- "1 Mounting to Optional Surface Mount Box r' -p __ PTri J't Wiring -Il SD500-PSDA I.. J;•: Installing SD500-LK SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com eIrc,l Do. be 142' O, Dimensions MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright 0 2003 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0136 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model PS-SKSA and SD500-PS fire alarm pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Updated 08-29-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct *V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Approvals NFPA71 &NFPA72 UL 864 CSFM 7300-0559:132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL r -SILENT KNIGHT by Honeywell S13500-AIM & SD500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The 5D500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The 5D500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description DIP switch programmable for fast The SD500-AIM and SD500-MIM are installation addressable input modules for use with Up to 2500 ft wiring distance from the lntelliknight fire alarm control either input module to contact panels (FACP5). The SD500-AIM Use up to 14 gauge wire addressable input module mounts to a UL listed 4"-square box. The SD500-MIM mini input module fits inside a single gang Electrical Specifications box. Both input modules are designed Standby Current: 0.55 mA to be used with pull stations, water flow Alarm Current: 23 mA max for one switches, and other applications device; 46 mA max for two devices; requiring dry contact alarm initiation 0.55 mA for each additional device devices. These modules are supervised, single Line Resistance: 500 max input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description closures and for open circuit wiring Dimensions: fault conditions. If a fault occurs in the 4.9" w x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) Each addressable input module is Weight: 3.6 oz (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500-MIM Physical Description Features Dimensions: Single contact monitor 1.5" W x 2.5" H x 0.7" D SD500-AIM supports Class A (Style (3.8 W x 6.4 H x 1.8 D cm) D) or Class B (Style B) contact Weight: 1.6 oz (45.4 g) monitor wiring Environmental SD500-MIM support for Class B (Style B) contact monitor wiring Operating Temperature: 32°F - 120°F (0°C - 49°C) Attractive ivory cover plate with the SD500-AIM Humidity: Small and lightweight size allows for 10010 - 93% non-condensing flexible mounting options with the SD500-MIM Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MlM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4-square or double gang electrical box. The 5D500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate I, = ,,------..- a -:---- - --- -T Compatible FACPs FACPs Ordering Information 5820XL SD500-AIM Input Module 5808 Addressable input module with ivory 5700 cover plate. SD500-MlM Input Module Addressable mini input module. D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev D, subject to change without notice. For more information, contact Silent Knight © 2008 Honeywell International Inc by Horey-.'eH 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0132 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: Model SD500-ARM Relay Module and SD500-AIM, SD500-MlM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SDSOO-ARM: 120 VAC, 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, -2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division C01 224T and C01 224TR Carbon Monoxide Detectors with RealTest® Technology The System Sensor CO 7224Tand CO 1224TR (round) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features RealTestO enables a functional test using canned CO Full compliance with UL 2075 A code-required trouble relay Wiring supervision with SEMS terminals A six-year end-of-life timer 12/24 VDC A low current draw of 20 mA in standby and 40 mA in alarm Versatile mounting for wall and ceiling Accurate and reliable electrochemical sensing technology Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the COI 224T Agency Listings LISTED 2075 With ReallTestO technology, the CO gas sensing cell used in the C01 224T and COI 2241R CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720:2009. Simply put the detector into RealTest mode, spray a sma I amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) When dangerous amounts of CO are detected, the C01 224T and C01 224TR detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The COI 224T and C01 224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code-required trouble relay to send a sensor failure or end-or-life signal to the control panel and the central station.The COI 224T and COI 224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panes. As 12/24 VDC detectors, the COI 224T and COI 224TR will operate on most industry security and fire alarm control panels. C01 224T and C01 224TR Carbon Monoxide Detector Specifications _J Carbon monoxide detector shall be a System Sensor model number COI 224T or C01 224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. I L Ts Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @30 VDC Trouble Contact Ratings 0.5 A @30 VDC - Size: CO 2241 ;j Length: 5.1 in, Width: 3.3 in, Height: 1.3 in C01 224TR Diameter: 6 in, Height: 1.3 in Approximate Weight COI 224T: 7 oz; COI 224TR: it oz Operating Temperature Range 32°F to 104°F (0°C to 40° C) Operating Humidity Range 22 to 901/6 RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Normal (standby) Blink 1 per minute - - Alarm -. Blink in temp 4 pattern Sound in temp 4 pattern RealTest Feature: The System Sensor COI 224T and C01 224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Push and hold the Test/Hush button for Spray canned CO agent into the detector. Verify CO sensing at the control panel. The two seconds to enter RealTest mode. The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20-60 seconds. indicate RealTest mode has started. NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). - Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. - End-of-Life Timer: After the detector's internal sensor has reached the end of its life, a trouble signal will be sent to the ' panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about six years. The detector must be replaced by the date marked on the inside of the product. -, CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement Ordering Information CO-PLATE C01 224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest Technology C01 224TR 12/24 volt, 4-wire system-monitored round carbon monoxide detector with Rea lTest' Technology. CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary _____'•\ 5}57J7 ©20i i Sys em Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product pionothe,uu&evsweo,for SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 current product Inf—eon, including he ~- verd- of thus dam shcec CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 5278-1653:0219 Page I of 1 CATEGORY: 5278 -- CARBON MONOXIDE DETECTORS LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models C01224, C01224T, and C01224TR Carbon Monoxide detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 10-33VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NFPA 720, and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee;s name, Model number, electrical rating and UL label. APPROVAL: Listed as Carbon Monoxide detectors for use with separately listed fire alarm control units. NOTE: Carbon Monoxide detectors are not intended/suitable for fire and smoke detection. 12-06-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division InnovC14 a 1 SYSTEM $ SENSOR 4-Wire Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology -Ai r velocity rating from 100 ft/min to 4,000 ft/mm (0.5 rn/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 1/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories The InnovairFiex D4120 4-wile photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The lnnovairFlex housing provides ample wiring space, a 3/4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on.Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFIex duct smoke detector can be customized to meet local codes and specifications without additional wiring.The new lnnovairFlex product line is compatible with all previous Innovair Agency Listings models, including remote test accessories. Q. WARNING: Duct smoke detectors are NOT a substitute for open ® L area smoke detectors; NOT a substitute for early warning detection; LISTED NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. lhnovairFlex' Duct Smoke Detector, Specifications The air duct smoke detector shall be a System Sensor ln nova irFlex D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second).The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK451 Multi-Signaling Accessory or the RTS451 KEY RemoteTest Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical specifications - Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; 5 in (12.74 cm) Width; 2.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: D4120 & D4S: 4° to 158°F (-20° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & D4S: -22° to 158°F (-30° to 70°C); D4P120; -40° to 158°F (-40° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/sec) Electrical Ratings go Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270pF max. 270 p max. N/A Reset voltage: 3.OVDC mm. 2.OVAC mm. t0VAC mm. Reset time: (with RTS451) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) . 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts: (SPST) 2.OA @ 30VDC (resistive) Alarm auxiliary contacts: (DPDT) 10A @30 VDC (resistive); 10A@ 250 VAC (resistive); ½ HP @240 VAC; 1/4 HP @ 120 VAC Note; Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 1Accessory LCurrent ! 2.OA @30 VDC (resistive); 2.OA @ 125 VAC (resistive) Device Standby Trouble Alarm APA151/APA451 12.5 mA n/a 30 mA Max. MHR/MHW 0 m n/a 29mAMax. RA100Z 0 m n/a 12 mA Max. RTS151/RTS151KEY 0mN12mA n/a 12mAMax. RTS2/RTS2-AOS 3.0mA max 16 mA Max. with strobe; 55 mA max; without strobe 30 mA max Note; Any combination of accessories may be used such that the given accessory loads are; 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFiex Sampling Tube The InnovairElex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05-0419 00 I ------------ I POWER INPUTS (NOTE 1) I I I 910 I OR I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB J" . 1, ? I SUPERVISORY CONTACTS I (NOTE 3) I 3 14 EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER ALARM 4(e) ALARM C. INITIATION CONTACTS (NOTE 4) s ALARM N.O. ----------- LAST DETECTOR DETECTOR IN THE LOOP NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Wiring for 4-wire Duct Smoke Detector and Accessories ------------ I POWER INPUTS (NOTE I) I 4VAC/D1 120 I FVACI I I 910 I OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB I SUPERVISORY CONTACTS I (NOTE 3) I UUFMUSTED 3 14 CONTROL PANEL ALARM 4 () ALARM C. INITIATION CONTACTS (NOTE 4) ALARM N.O. IL FIRST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or 24VAC 50-60Hz. 120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. Please refer to the corresponding installation manual for accessory wiring diagrams. Important Notes on 2:1 Sensor-to-Power Caoabilit .2:1 sensor-to-power capability is not available for all InnovairElex models. The feature is only available on the D41 204-wire conventional models. .2:1 sensor-to-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120. Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the lNT+ terminal on unit 1 t the lNT+ terminal on unit 2 and so on. Similarly, connect the lNT/AUX- terminal on unit ito the INT/AUX- terminal on unit 2 and soon. Up to 50 D4120 units, 50 D4P1 20 units, or 50 units of combination may be interconnected. Up to 10 DH 100ACDC units may be interconnected. Please note that each of the 9 DH1 OOACDC units interconnected may be replaced by three D4P120 units. Therefore, when using the interconnect feature a single DH1 OOACDC can drive either 9 DH1 00ACDCs or 27 D4120 units. NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. 005-04 19001 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. SMOKE NO 6 RTS151 ULS4OtI RTS151 KEY uLS2522 APA151 UL S4011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL 54011 MHR UL 54011 AIDS Ordering Information IMTiIi[.. D4120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only MHR Mini Horn, Red D4P120 4-wire photoelectric power board component only, MHW Mini Horn, White 24VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head P48-21-GO End cap for metal sampling tubes DST1 Metal sampling tube duct width up to 1 f (0.3m) RA1 OOZ Remote annunciator alarm LED DST1 .5 Metal sampling tube duct widths t ft to 2 ft (0.3 to 0.6 m) RTSt St Remote test station DST3 Metal sampling tube duct widths 2 It t04 ft (0.6 to 1.2 m) RTS1 51 KEY Remote test station with key lock DSTS Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) RTS2 - ACS Multi-signaling accessory DSTt 0 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) APAt 51 Remote annunciator with piezo alarm DH400 OE-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 ft (0.3m) M02-04-00 Test magnet "STEM 3825 Ohio Avenue. St. Charles, IL 60174 SENSOR Phone: 800-SENSOR2 . Fax: 630-377-6495 currentproduct nfnndng the latest version of this dam hee CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0207 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (WI OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models D4120, D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD412OX, LD4120H, D4S, D4P120, CD4P120 LD4P120X, LD4P120H, TD4C, PD4120, YD4120, YD4P120, and AD4P120 four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 2D51 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4C LD412OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C, LD412OX, LD4120H, LD4P120X and LD4P120H *do not have 120 VAC rating). INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-27-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Selectable Output Horns, Strobes, and Horn/Strobes SpectrA lert Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wail Automatic selection of 12-or 24-volt operation at 15 and 1.5/75 and ceiling strobes and horn/strobes. candela Plug-in design When installing Advance products, first attach a universal mounting Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four-inch square, four-inch octagon or double-gang 30, 75, 95, 110, 115, 135, 150, 177, 185 Junction box. The two-wire mounting plate attaches to a single-gang Same mounting plate for wall- and ceiling-mount units junction box. Shorting spring on mounting plate for continuity check before Next, connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. Tamper resistant construction Outdoor wall and ceiling products rated f:om . 40°F to 1.51°F Finally, attach the horn, strobe or horn/strobe to the mounting plate Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves. The Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification Outdoor products rainproof per UL 50 (NEMA 3R) appliances, Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or cpilinn (li rclnnr hnrnc a re available for Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Aaencv Listincis SIBIIALINII MEA LISTED APPROVED approved SpectrAlert Advance Specifications . . 1TT ____ ETIJ General SpectrAlert Advance horns, strobes and hcrrVstrobes shall mount to a standard 4 x Ax 1½-inch brick- box, 4-inch octagon brick box or double-gang hack box two-wire products shall also mount toe single-germ 2 x Ax I f's-inch back box. A universal I coors/rig plate shell he wee for rrrountl'ig ceihng arid wall products. the notification appliance Circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circui( Module :wcossory, shall he powered from a non-coded nobfication appliance circuit output ard shall operate on a nominal 12 o 24 vets. When used with thc Sync—Circuit Module, 12-volt rated notification appliance circuit outputs shsl rtpersrc' between nine and 12.5 volts; 24-volt rated rorificabor appliance circuit outpu:s shall operate between ;? and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheri from a regulated DC. or hill-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field selectable candela settings including 15, 1S/75,30, 75,95,110,115,135,50,1!? 185. Strobe The strobe shall be it Syste'rrt Sensor Spe.ctrAlert Advance Model listed to UL 19/1 and I iall be approved for fire prctoct ye service. 1 he strobe shall be wired as a primary-signdlirig notification appliance and comply with the Americans with Disabihties Act requirements for visible signaling appliances, flashing at 1Hz over the strcrbek entire operating voltage range. 1he strobe light shall consist ofa xenon flasim tube arid associated lens/reflector systerrr. Horn/Strobe Combination The horn/strobe shall be System Sensor SpectrAlert Advance Model listed to UL 19/1 arid UL 464 and shall be approved for fire protective service. The horn/st'che shall be wired as a primary-signaling notification appliance and comply es/tb il'c Americans with Disabmlmtios Act requirements for smhlo signaling appliances, flashing at 1hz ovcrthe strobe's entire operating voltage range. 1 he strobe light shall consist of a xenon flash tuba and associated lens/reflector ss'stern.'l hehom shall have three audibility options and ran option to switch between a temporal three-pattern and a non-temporal (Continuous) pattern.These options are set by a multiple position switch. On four-wire procucts, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate aria coded or non-cooed power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL arid shall operate between rrrinus 40 degrees and 151 degrees Fahierhcis.i'he products shell he listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries, Synchronization Module The module shall be a System Sensor Sync .Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 11 iz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models oe'er a single pair of wires he module shall mount to a 4Vr x 4f/' x 21/8-inch back box. the module shall also control two Style's (class B) circuits or one Style / (class A) cmrcuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32F to 120F (0CC to 49CC) K Series Operating Temperature —40'1` to 15 l"F (-40"C to 66%) Humidity Range 10 to 93% nun-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12D6/FWR or regulated 24DtJFWR' Operating Voltage Range' 8 to 17.5 V(t7Vnominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12to18AWG Ceiling mount dimensions (including lens) 6.8 'diamote' x 2.5 'high (1/3 'cm claines-c"t x 64 rnrrm high) Wall mount dimensions (including lens) 5.6% x 4./W x 2.5"C (t 42 miTre L x 119 mini W x 64 mm Dl Horn dimensions 5.6'l.x4.7'dlx 1.3D(147 mm Lx 119mrnWx33 nrmD) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.91. x 5.0W x 221))151 mm Lx 128 mm W x 56mm D) Ceiling-mount back box skirt dimensions (BBSC-2, 8BSCW-2) 7.1 "diameter x 2.75" high (180 min diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5./1 x 5.1 'Wx 2.0% )145 me' Lx 130 mm W 51 mm Dl Ceiling-mount weatherproof back box dimensions )SA-WBBC) 7.V diameter' x 20' high (180 rem diarrmeter x 51 mnisr high) Notes: Full Wave Rectified (FAIR) voltage is non-regulated, time varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V ncmninal only for 15 and 5/75 s,d, is alas-en Fri UL Current Draw Data TETI I - 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d8 DC FWR DC FWR Standard 15 123 128 66 .71 -lernporal High 57 55 69 /5 Candela Range l5/75 142 148 77 81 Temporal Mudum 4-1 49 58 ((9 NA NA 94 96 Thmporl Few 38 44 44 48 75 NA NA 158 153 Non temporal I ugh 57 56 69 15 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 10 NA NA 202 195 Non-temporal Low 41 44 50 50 I 1 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range ISO NA NA 246 220 Coded Low 40 46 52 CO 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DClnput 15 1 5/75 15 15/75 30 75 95 110 115 -Temporal High 13, 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Nor-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Nor temporal Low 131 144 68 79 96 156 182 201 210 FWRInput Temporal High 136 55 88 97 112 168 190 210 218 lemporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Nor-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 154 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 - 1 185 Temporal High 245 259 290 297 Temporal 1-ligh 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 temporal Low 207 221 248 256 Nor-temporal 1-11gb 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Mediurn 212 259 293 299 Non-temporal Medium 219 232 262 267 Nor-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures listed candela ratinGs must he reduced in sccordance with this table. Horn Tones and Sound Output Data I 163 24 Volt Nominal Listed Candela Candela rating at-40F 15 15/75 Do not use below 32'F 30 75 44 95 70 11 110 0 115 115 135 135 150 150 177 177 185 185 Switch Switch VURS voris ineverwarant Mnecnolc Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 ler rrpordl High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 85 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 39 4 Non-reirrporal High 82 82 88 88 93 92 100 100 5 Non-ternpoial Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 7 Coded 18gb 82 82 88 88 93 92 101 101 8m Coded: McdiUrn 78 78 85 35 90 90 97 93 9 Coded Low 75 75 81 81 88 85 96 92 'Settings 7,8, and 9 are not available on 2-wire norr,/strohcs. lert Advance Dimensions Ceiling-mount horn/strobes 7.1W 5.05_____-.. .-2.23'.j Oja. 29 0 0 Q Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information / . (~~) . 7 7 .00,0 " ;0 Wall weatherproof back box 7-i, Dia. rAM Ceiling weatherproof back box I 1 Wall Horn/Strobes Ceiling Horn/Strobes (contd.) P2Rw 2-wilL mm/Strobe, S rmdatd cd', Rod PC2W' 2-',viro Horn/Strobe, Standard cd, While P2RH 2-wire Horn/Strobe, High cd, Bets PC2WH 2-wire Horn/Strobe, High cd, White P2RKa 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4-wire Horn/Strobe, Standard Cd, Red P2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor PC1RH 4-wire Horn/Strobe, High cd, lied P2W 2-wire '-torn/Strobe, Standard cd,White PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P2WH 2-wire Horn/Strobe, High cd, White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4R 4-wire -torn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd,White 114RH 4-wire Horn/Strobe, High cd, Red PC4WF-I 4-wire Horn/Strobe, High cd,Whit P4R.K 4-wire I torn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor SCR Strobe, Standard cd, Red P4W* 4-wire Horn/Strobe, Standard cd White SCRH Strobe, High cd, fled P4WH 4-wire Horn/Strobe, High cd White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor 510' Strobe, Standard rd, Red SM11 Sttnh' Standwr.1 cd, White SRI Strobe, High cd, Red SCWH Strobe, High cd, White SRK Strobe, Standard cd, Rod, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red 5/0 Strobe, Standard cd, White kIRK I-torrr, Red, Outdoor SWH5 Strobe, High cd, White HW Horn, White Ceiling Horn/Strobes Accessories PC210 2-wire I torn/Strobe, Standard I cd, Red 885-2 Back Box Skirt, Wali., Red PC2RH 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 [lack Box Skirt, Ceiling, Red 1rC2RI..lK 2-wire Horn/Strobe, High cd, Red, Outdoor BBSCW-2 Back Box Skirt, Cc'ilinu, White Notes: Add "-P'to model number for plain housing (no"FIIlE"marking on cover), e.g., P2R,1) t Add "-SP"to model number fer"FUEGO" marking on cover, e.g., P2R-SP R "Standard cd'refers to strobes thin include 15,1-9/75,30,75,95, 11 0, and 115 candela settings. "High cd,"refers to strobes that include 135, 150, 177, and 185 Candela srrttirrgs. All outdoor units ending in"Kinclude a weatherproof back box. Th S TEM 3825 Ohio Averrue. St. Charles, IL 601/4 r'v.-". cr SENSOR' .._$ Phone: $00-SENSOR2 Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING.PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: 7125-1653:0186 Page 1 of 1 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED System Sensor, Unincorporated Div of Honeywell Int'l Iric.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating and UL label. Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as °horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM _1 LISTING SERVICE LISTING No. 7135-1653:0189 Page 1 of 1 CATEGORY: 7135-- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models HR, HW Horns and CHR, CHW chimes, Intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use. "K" suffice models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA "4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), "SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Models CHR and CHW are intended for private mode use only. Suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8- 17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's InstaLlation Instruction Manual for details. *Rev 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division