HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FA090050; Permit4/4/25, 3:14 PM FA090050 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 5781 VAN ALLEN WY Permit Type: FALARM Parcel No: 2121304400 Lot #: 0 Permit No: FA090050 Status: ISSUED Applied 11/4/2009 Approved: 11/4/2009 Reference No.: Issued: 11/4/2009 PC #: Inspector: Project Title: LIFE TECHNOLOGY FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: GRIFFIN CAPITAL CARLSBAD POINTE INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) 1 Add'I Fees ($) I Total ($) Balance ($) 125 0 125 0 about:blank 1/1 INVITROGEN CP-21 T.I. 5781 VAN ALLEN WAY CARLSBAD, CA. 92008 FIRE ALARM T.I. SUBMITTAL [ CITY OF CARLSBAD FIRE DEPARTMENT Submitted By: APPROVED SubjeCt to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit violation of any law. 3830 Calle Fortunada orappr ye the San Diego, CA 92123 By Lic. #707408 (858) 654-3133 INVITROGEN CP-21 T.I. FIRE ALARM SUBMITTAL OTY DESCRIPTION MODEL # MANF. CSFM# 5 HORN/STROBE MULTI-CD CLG AS-24MCC WHEELOCK 7125-0785:131 3 STROBE MULTI-CD CLG RSS-24MCC WHEELOCK 7125-0785:141 LOT 14/2 FIRE CABLE ADT/GENESIS 7161-1487:100 LOT 18/4 FIRE CABLE ADT/GENESIS 7161-1487:100 Series AS Audible Strobe Appliances and Series AH Audibles SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MOW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wbeelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971 UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30175/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Piate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range' using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 nYLLLI A.. <S_> NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identity the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30175/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30175/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA dBA Per UL 464 @10 ft. 10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-244CC AS-24MCCI-$ 1575cd 15cd 30cd 75cd llOcd 1 35c 185cd 15cd 3Ocd 75cd 95cd 11 Sod 177ad High (99) 24 vdc 0.062 1 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0088 0114 0.165 0.205 0.250 0.320 dBA ULmax° 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.306 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.066 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Wall Mount Audible Audible 12 VDC Models Strobe Table 4:Average Current* (AMPS) For Series ASWP# 1 High dBA Medium dBA Low dBA Aft12 AS-121676W Voltage Setting Setting Setting (99) dBA (95) dBA (90) dBA High 99) 12 vdc 0.163 0.260 24.0 VDC 0.128 0.105 0.098 ULmax° 0.192 0.320 dBA ULMax* 0.168 0.155 0.150 Med (95) 12 vdc 0.076 0.195 UL max 0.108 0.275 dBA * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current Within the listed voltage range (16-33v Low (90) 12 vdc 0.039 0.175 for 24v units). For strobes the UL max current is usually at the minimum dBA listed voltage (16V for 24v units). For audibles the max current is usually UL max* 0.058 0 . 265 at the maximum listed voltage (33v for 24v un(ts). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams * SERIES AS APPLIANCES NON-SYNCHRONIZED FRO [T0 NEXT[] PRECEDING: OR EOLREJ OR FACPE:J APPLIANCEEJ _PPLIJ\NCED SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-SCP and PS-12124-8MP CUTPUTSO EOLRO F1 1-40 - 4-CLASSO A: 050 A.S0 aS 0 c: AM RSSO Series PS-12/24-4 SO or PS-12/24-8!{E( SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE 50RE0 OSTROBEO StrObeO NACO circuitc *ud5b aD EOLRD PEI E~A.~dibleD -5.idsb aD 15CC] CircuitO SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES __DSM #10 DSM Interconnecting wiring shown. Maximum twenty (20)0 'For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation lnstruct:ons P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-8MC. Specifications and Ordering Information Model Number Order Code Strobe Candela Non- Sync Syncw/SM, DSM or PS..24..81VIC 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting Options*** AgencyApprovals U TLMEA CSFM FM BFI S-24MCW-FR 9024 15/30175/110 X X X - - A,BDEF,G,H,JNOR,X X X X X X S-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,DE,F,G,H,J,NO,RX X X X X X .S-24MCW)--FR 3468 135/185 X X X - X - AB,D,EFGHJN,O,R,X X X X X * S-24MCWH-FW 3469 135/185 X X X - - ABDEFGH,j,NOR,X X X X X * AS-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,EF,G,H,J,NO,R,X X X X X X AS-121575W-FR 7410 15(75onAxis) X X - X X - A,BD,E,F,G,H,J,NO,R,X X X X X X S-24MCC-FR 3161 15/30175/95 X X X - - X A,BDE,F,G,H,JNO,R,X X X X X * IS-24MCC-FW 3162 15/30175/95 X X X - - X A,B,D,EFG,H,JN,OR,X X X X X S-24MCCH-FW 3467 115/177 X X X - - X A,BD,EFGHJ,N,O,R,X X X X X * SWP-2475W-FR 9012 75 @ -31°F X X X - X - I(see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X A,BD,EF,GH,J,NO,R,X X X X X X H-24-W 7893 - X X X - X X AB,DEFG,H,JN,OR,X X X X X X H-12-R 7891 - X X - X X X AB,D,E,F,GHJ,NOR,X X X X X X H-12-W 7894 - X X - X X X A,B,DE,FG,HJ,NO,R,X X X X X X H24WPR** 7416 - X X X - X X K X X X - X H12WPR** 7415 - X X - X X X K X X X X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. Arc nitects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at .15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 AS/AH 10/07 CAUFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECHON - OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM - LISTING SERVICE LISTING No. 7i25-0785131 Page 1 of 2 CATEGORY: FirAlarm Devices for the Hearing-Impaired LISTEE: Whéelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1 215W, -2415W, -1230W, -2430W, -1 21 575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -241 OOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *AswP..2475c audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASwp.24Mc and *ASWP..24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15175cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 1 35cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at-40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, ANDAS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audibleMsual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30,2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division RSS Round Series RSS and RSSP Strobes and Strobe Plates Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30175/110cd or the high intensity MCWH strobe with field selectable 1351185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelocks synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADNNFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 %fII mount Multi-Candela models are available with Field Selectable Candela Settings of 15130/75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. 4 WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS!RSSP -Wall Mount Ceiling Mount 241575W 24MCW 24MCWH '24MCC 24MCCH RSS/RSSP Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cdl . 15cd .30cd 75cd 95cd 11 5c 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0249 0.300 0.420 RSS/RSSP RSS!RSSP Wall Mount 24VDC _____________ * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.255 see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams # SERIES RSSIRSSP APPLIANCE FROM + TO NEXT PRECEDING - APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE SYNC0 NAC CIRCUIT - OUT 0+OUT 1 0INl RSS RSS RSS 0MINUS LI 1 AUDIBLE 2 ROBE ØMINUS IN 2 RSS RSS NAC 0 + OUT 2 CIRCUIT RETURN SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Strobe NAC Cir. 0+ SS RSS I I I I F lsj#' - A sync Strobe NAC C de DSM #3 P ___ RSS RSS JLrr?-sr7- Strobe NAC Cir. DSM Interconnecting wiring shown. Maximum of twenty (20) STROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM ____ _______ ______ + APPLIANCE PRECEDING 1 R - OR EOLR APPLIANCE, SYNC MODULE, POWER ____ ____ SUPPLY ORFACP 1+ -+- STROBE AUDIBLE SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F STROBE STROBE Strobe A NAG ø Is' Gircjit Audible P EOLR Audible STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + TO NEXT FR BC ED WE APPLIANCE APPLIANCE OR - ___________________ __________________ - OR EOLR FAC? + TO NEXT PRECEDING STROBE OR STROBE. SYNC - - - 11 1 1 — — - EOLR MODULE. POWER SUPPLY DI FACP STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS-24-8MC. SERIES RSS!RSSP APPLIANCES SYNCHRONIZED WITH PS-12!24-8CP or PS-12124-8MP Series PS-12124-8MP F 1-4 :BMOUTPUTS EOLR 4-CLASS A OR S A ASS C 2-CLASS P AS RSS Series PS-12/24-SMP Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options Square or Round Agency Approvals — — UL MEA - - CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30175/110 X - X - BDE,F,GH,J,N,OR,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30175/110 X - - X BD,E,F,G,H,J,NO,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,DE,F,GH,J,N,OR,X Square I X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X BD,E,F,GHJ,N,OR,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,FG,HJ,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,FG,H,J,NO,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - X B,DE,FGHJN,OR,X Square X X X X RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,FGH,J,NOR,X Square X X X X RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X BDE,FG,H,J,NO,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,DEF,G,H,JN,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,EFG,H,JN,O,R,X Round X X X X RSS-24MCWH-FR 3465 X X 135/185 X X B,DE,F,GHJ,N,OR,X Square X X I X X RSS-24MCWH-FW 3464 X X 135/185 X X BDE,F,G,H,J,N,OR,X Square X X X X RSSWP2475WFR** 9013 X - X 180@ 77*F X X X - B,D,E,F,G,H,J,NOR,X Square X X X X * RSSWP-2475W-FW" 3034 X - X X X - X BD,EF,G,HJN,O,R,X Square X X X X RSSP-121575W-FR 77981 X • X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X R SSP-241 575W-FR 7793 X - X 15 (75 On Axis) - - X - D,E,Z Square X X X X I X *PENDING All models sync with Wheelock SM, DSM or PS-12124-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second overthe Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/301751110cd or 135/185cd for wall mount and 15130/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatiblewith Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, orthe SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with tATheelock, Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S0410 RSS/RSSP 02108 CALIFORNIA DEPARTMENT OF FOREST1Y & FIRE PROTECTION OFFICE OF THE STATT, FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS IJSFING PROGRAM LISTING SERVICE LISTING No. 71250785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-C RSS-CR RSSP-#CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24M CCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRSMCW; *ZRSMCCH and *ZRSMCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 7575cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRSMCW: Selectable 15cd, 30cd, 75cd orll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS.MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *zRS.McJL: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-20061w This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June-30,-2010 Authorized By: FRANCIS MATEG, Program Coordinator