HomeMy WebLinkAbout2110 RUTHERFORD RD; ; AS150151; Permit4/10/25, 8:41 AM AS150151 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS 150151
2110 RUTHERFORD
Job Address: Status: ISSUED
RD
Permit Type: SPRINK Applied 5/28/2015
Parcel No: 2120702200 Approved: 5/28/2015
Lot #: 0
Reference No.: Issued: 5/28/2015
PC #: Inspector:
Project Title: GENOPTIX LABORATORY INSTALL NEW TENANT PIPING AND
SPRINKLER AS SHOWN ON THE DRAWINGS. NEW SPRINKLER
TO BE SUPPLIES FROM EXISTING 1" OUTLETS AND OR
EXISTING SPRINKLER PIPING.
Applicant: Owner:
INDUSTRIAL FIRE SPRINKLER CO INC BLACKMORE AIRPORT CENTRE
C/O ALLEN J BLACKMORE
3845 IMPERIALAV P 0 BOX 424
SAN DIEGO CA RANCHO SANTA FE CA
619-266-6030 619-266-6035
Fees Add'I Fees Total Balance
280 0 280 0
about:blank 1/1
HORIZONTAL SIDEW
0
VEF
SIDE
PENDENT
A UTOMA TIC SPRINKLERS
GL SERIES
UPRIGHT. PENDENT
VERTICAL SIDEWALL
HORIZONTAL SIDEWALL
CONVENTIONAL (OLD STYLE)
DESCRIPTION AND OPERATION
The Globe CL Series Sprinkler is a low profile yet durable
design which utilizes a frangible glass ampule as the thermo-
sensitive element. While the sprinkler provides an aestheti-
cally pleasing appearance, it can be installed wherever stan-
dard spray sprinklers are specified. This sprinkler series is
available in various styles, orifices, temperature ratings and
finishes to meet varying design requirements.
The heart of Globe's GL Series sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fluid. When heat is
absorbed, the liquid within the bulb expands increasing the
internal pressure. At the prescribed temperature the internal
pressure within the ampule exceeds the strength of the glass
causing the glass to shatter. This results in water discharge
which is distributed in an approved pattern depending upon the
deflector style used.
The sprinkler and escutcheon are not factory assembled.
Assembly is done in the field.
TECHNICAL DATA
See reverse side for Approvals and Specifications.
Temperature Ratings - 135°F (570C), 155°F (680C), 175°F
(79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C).
500°F (260°C) Available Upon Request Without Approvals.
Water Working Pressure Rating - 175 psi (12 Bars).
Factory tested hydrostatically to 500 psi (34 Bars).
Maximum low temperature glass bulb rating is -67°F (-550C).
Frame - bronze a Deflector - brass a Screw - brass
Bulb seat - copper a Spring - nickel alloy o Seal - teflon
Bulb - glass with glycerin solution, 5mm size.
UPRIGHT CONVENTIONAL
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
CLASSIFICATION AVAILABLE
[_SPRINKLER [
BULB COLOR MAXIMUM - CEILING N.F.P.A.
TEMPERATURE TEMPERATURES
ORDINARY 135'F/1 55'F 57Cl68°C ORANGE/RED 100°F 38°C
INTERMEDIATE 1750F/200 *F 79 C/93°C YELLOW/GREEN 150 F 66 *C
HIGH 286'F 141'C BLUE 225 *F 107'C
EXTRA HIGH 360°F 182°C MAUVE 300°F 149°C
ULTRA HIGH 500'F 260'C BLACK 475'F 246 *C
4077A1 RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231
DECEMBER 2006 A-65 BULLETIN GL5661, REV. #3
A UTOMA TIC SPRINKLERS
GL SERIES
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES
2.8 (39 metric) 1/2 NPT 2 1/4" (5.7 cm) Factory Bronze
Satin Chrome 2
4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Bright Chrome
White Polyester 5.6 (80 metric) 1/2" NPT 2 1W'(57 cm) Black Polyester
7.8 (111 metric) 1/2' NPT 2 1/4" (5.7 cm) Wax Coated 1,4
Lead Coated 2,4
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Wax over Lead 3.4
NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1 HORIZONTAL SIDEWALL IS 2 9/16".
2 FINISHES AVAILABLE ON SPECIAL ORDER.
3 WAX COATING UL LISTED UP TO 200*F ONLY.
UL AND C-UL LISTED CORROSION RESISTANT-
POLYESTER MUST BE SPECIFIED ON ORDER.
APPROVALS
STYLE SIN ORIFICE 135°F 155°F 175°F 200°F 286°F 360°F * 500°F cULus FM LPC CE NYC - DOB
MODEL SIZE 57°C 68°C 79°C 93°C 141°C 182°C * 260°C MEA 101-92-E
GL2861 2.8 X X X X X X X X - -- -- x
GL4261 4.2 X X X X X X X X -- -- -- X
UPRIGHT GL5661 5.6 X X X X X X X X X X X X
GL8161 7.8* X X X X X X X X X - --- X
GL8164 8.1 X X X X X X X X X X X X
GL2851 2.8 X X X X X X X X - -- -- X
GL4251 4.2 X X X X X X X X - - - X
PENDENT GL5651 5.6 X X X X X X X X X X X X
GL8151 7.8* X X X X X X X X X - -- X
GL8156 8.1 X X X X X X X X X X X X
VER11CAL GL5675 5.6 X X X X X X X X X -- -
SIDEWALL GL8176 8.1 X X X X X X X X -- -- -- --
GL2870 2.8 X X X X X X X X -- - -- x
HORIZONTAL GL4270 4.2 X X X X X X X X -- - - X
SIDEWALL § 45670 5.6 X X X X X X X X X - - X
GL8171 8.1 X X X X X X X X - - - -
CONVEN110NAL GL5668 5.6
(OLD STYLE) GL8169 8.1 X X X X X X X - -- X X --
*500*F AVAILABLE UPON REQUEST WITH NO APPROVALS § HORIZONTAL SIDEWALL UL LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6".
t VERTICAL SIDEWALL UL LISTED FOR LIGHT HAZARD ONLY.
PENDENT VERTICAL SIDEWALL UL LISTED FOR 6' MIN. SPACING.
UPRIGHT VERTICAL SIDEWALL UL LISTED FOR 9' MIN. SPACING.
* 1/2" NPT.
ORDERING INFORMATION
SPECIFY
,Quantity * Model Number • Style
Orifice • Thread Sizes . Temperature
Finishes desired
Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.a.)
oy~, TOOPT7,
FIRE SPRINKLER CORPORATION
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its own
manufactured products found to be defective in material
or workmanship for a period of one year from date of
shipment.
For specific details of our warranty please refer to
Price List Terms and Conditions of Sale (Our Price List).
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583 , FAX 989-846-9231
1-800-248-0278 www.globesprinkIer.com
DECEMBER 2006 PRINTED U.S.A. BULLETIN GI-5661, REV. #3