HomeMy WebLinkAbout2110 RUTHERFORD RD; ; AS150151; Permit4/10/25, 8:41 AM AS150151 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS 150151 2110 RUTHERFORD Job Address: Status: ISSUED RD Permit Type: SPRINK Applied 5/28/2015 Parcel No: 2120702200 Approved: 5/28/2015 Lot #: 0 Reference No.: Issued: 5/28/2015 PC #: Inspector: Project Title: GENOPTIX LABORATORY INSTALL NEW TENANT PIPING AND SPRINKLER AS SHOWN ON THE DRAWINGS. NEW SPRINKLER TO BE SUPPLIES FROM EXISTING 1" OUTLETS AND OR EXISTING SPRINKLER PIPING. Applicant: Owner: INDUSTRIAL FIRE SPRINKLER CO INC BLACKMORE AIRPORT CENTRE C/O ALLEN J BLACKMORE 3845 IMPERIALAV P 0 BOX 424 SAN DIEGO CA RANCHO SANTA FE CA 619-266-6030 619-266-6035 Fees Add'I Fees Total Balance 280 0 280 0 about:blank 1/1 HORIZONTAL SIDEW 0 VEF SIDE PENDENT A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe CL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermo- sensitive element. While the sprinkler provides an aestheti- cally pleasing appearance, it can be installed wherever stan- dard spray sprinklers are specified. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C). 500°F (260°C) Available Upon Request Without Approvals. Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-550C). Frame - bronze a Deflector - brass a Screw - brass Bulb seat - copper a Spring - nickel alloy o Seal - teflon Bulb - glass with glycerin solution, 5mm size. UPRIGHT CONVENTIONAL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE [_SPRINKLER [ BULB COLOR MAXIMUM - CEILING N.F.P.A. TEMPERATURE TEMPERATURES ORDINARY 135'F/1 55'F 57Cl68°C ORANGE/RED 100°F 38°C INTERMEDIATE 1750F/200 *F 79 C/93°C YELLOW/GREEN 150 F 66 *C HIGH 286'F 141'C BLUE 225 *F 107'C EXTRA HIGH 360°F 182°C MAUVE 300°F 149°C ULTRA HIGH 500'F 260'C BLACK 475'F 246 *C 4077A1 RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 DECEMBER 2006 A-65 BULLETIN GL5661, REV. #3 A UTOMA TIC SPRINKLERS GL SERIES SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2 NPT 2 1/4" (5.7 cm) Factory Bronze Satin Chrome 2 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Bright Chrome White Polyester 5.6 (80 metric) 1/2" NPT 2 1W'(57 cm) Black Polyester 7.8 (111 metric) 1/2' NPT 2 1/4" (5.7 cm) Wax Coated 1,4 Lead Coated 2,4 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Wax over Lead 3.4 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1 HORIZONTAL SIDEWALL IS 2 9/16". 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 WAX COATING UL LISTED UP TO 200*F ONLY. UL AND C-UL LISTED CORROSION RESISTANT- POLYESTER MUST BE SPECIFIED ON ORDER. APPROVALS STYLE SIN ORIFICE 135°F 155°F 175°F 200°F 286°F 360°F * 500°F cULus FM LPC CE NYC - DOB MODEL SIZE 57°C 68°C 79°C 93°C 141°C 182°C * 260°C MEA 101-92-E GL2861 2.8 X X X X X X X X - -- -- x GL4261 4.2 X X X X X X X X -- -- -- X UPRIGHT GL5661 5.6 X X X X X X X X X X X X GL8161 7.8* X X X X X X X X X - --- X GL8164 8.1 X X X X X X X X X X X X GL2851 2.8 X X X X X X X X - -- -- X GL4251 4.2 X X X X X X X X - - - X PENDENT GL5651 5.6 X X X X X X X X X X X X GL8151 7.8* X X X X X X X X X - -- X GL8156 8.1 X X X X X X X X X X X X VER11CAL GL5675 5.6 X X X X X X X X X -- - SIDEWALL GL8176 8.1 X X X X X X X X -- -- -- -- GL2870 2.8 X X X X X X X X -- - -- x HORIZONTAL GL4270 4.2 X X X X X X X X -- - - X SIDEWALL § 45670 5.6 X X X X X X X X X - - X GL8171 8.1 X X X X X X X X - - - - CONVEN110NAL GL5668 5.6 (OLD STYLE) GL8169 8.1 X X X X X X X - -- X X -- *500*F AVAILABLE UPON REQUEST WITH NO APPROVALS § HORIZONTAL SIDEWALL UL LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". t VERTICAL SIDEWALL UL LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL UL LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL UL LISTED FOR 9' MIN. SPACING. * 1/2" NPT. ORDERING INFORMATION SPECIFY ,Quantity * Model Number • Style Orifice • Thread Sizes . Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.a.) oy~, TOOPT7, FIRE SPRINKLER CORPORATION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 , FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com DECEMBER 2006 PRINTED U.S.A. BULLETIN GI-5661, REV. #3