Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2110 RUTHERFORD RD; ; FS140019; Permit
4/10/25, 8:40 AM FS140019 Permit Data City of Carlsbad Fixed Systems Permit 2110 RUTHERFORD Job Address: RD Permit Type: FIXSYS Parcel No: 2120702200 Lot #: 0 Permit No: FS140019 Status: ISSUED Applied 7/1/2014 Approved: 7/29/2014 Reference No.: PC #: Project Title: Issued: 7/29/2014 Inspector: GENOPTIX MEDICAL LAB RM 1104_NEW INSTALLATION OF FULLY AUTOMATIC (NO HUMAN INTERVENTION REQUIRED) ANSUL, INERGEN (IG-541) CLEAN AGENT FIRE SUPPRESSION SYSTEM. A CONTROL PANEL WITH BATTERY BACKUP WILL BE INSTALLED FOR DETECTION & CONTROL FUNCTIONS OF THE SYTEM. Applicant: JAM FIRE PROTECTION INC 8254 RONSON RD SAN DIEGO CA 858-495-2328 858-495-2335 Owner: BLACKMORE AIRPORT CENTRE C/O ALLEN J BLACKMORE P0 BOX 424 RANCHO SANTA FE CA Fees ($) I Add 'I Fees ($) Total ($) Balance ($) 229 L 0 229 0 about:blank 1/1 Genoptix Medical Laboratory Server Room 1104 2110 Rutherford Rd. Carlsbad, CA 92008 INERGEN - Clean Agent Fire Suppression System System Components & Calculations 1st Release INSTALLING CONTRACTOR: JAM Fire Protection, Inc. 1930 S. Myrtle Ave. Monrovia, CA 91016 V. 626.256.4400 F. 626.256.4401 CONTRACTED BY: Genoptix Medical Laboratory 2110 Rutherford Rd. Carlsbad, CA; 92008 Contact: Stinson Lamb V. 760-516-5583 SUBMITTED TO: Carlsbad Fire Department FS140019 I INERGEN (IG-541) Clean Agent Fire Suppression System MECHANICAL COMPONEN The equivalent length of the valve is equal to 20 ft (6.1 m) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300; Meets TC3AM 176 or TC3AAM 176 Valve Brass Safety Relief Valve Brass Valve/Cylinder UL Listed (EX-4510); Assembly Listed for use with FM Approved systems Shipping Cap Steel Description The cylinder is factory filled with lNERGEN agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects 0 the valve while in shipment. Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft3 (m3) ft3 m3 lb (kg) in. (mm) In. (mm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (1339) 8.5 (216) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (1466) 9.3 (236) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (1516) 10.7 (272) 426620 (LC) 350 (9.9) 355 (10.1) 217 (98) 60.2 (1529) 10.5 (268) 428646 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (1699) 11.0 (279) 426150* (LC) 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (1699) 11.0 (279) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (1339) 8.5 (216) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (1466) 9.3 (236) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (1516) 10.7 (272) 426621 (LC) 350 (9.9) 355 (10.1) 217 (98) 60.2 (1529) 10.5 (268) 426259 (LC) 435 (12.3) 439 (12.4) 1 260 (117.9) 1 66.9 (1699) 1 11.0 (279) I 1 I I I I I I I I ANSUL LIIW(~aSy.t.m. System Components UL EX-4510 2-1-12 Page 1-1.1 REV. 5 CV-98 Valve/Cylinder Shipping Assembly I I * Note 1: For Shanghai version, order Part No. 430935. Note 2: For Shanghai version requiring 172-bar cylinder (rating on cylinder not actual pressure in cylinder), order Part No. 437299. CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD .-.-------.. VALVE TAG HEIGHT TO OUTLET CENTER A 002251 CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no Internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal Is broken, the warranty Is voided. Note: Use Flexible Discharge Bend (Part No. 427082) when attaching valve to supply pipe or manifold. 3112 IN. jPRESSURE (89 mm) REFERENCE GAUGE SAFETY RELIEF VALVE \ / \ 002252 tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Are Products LP. Products Marinette, WI 54143-2542 www.ansUt.com All rights reserved. Form No. F-9877-05 ANSUL LRW@nsy.t.In. System Components UL EX-4510 2-1-12 Page 1-3.4 REV. 3 Valve Electric Actuation 1 I I I Description Electrical actuation of an agent cylinder and/or selector valves is accomplished by an HF electric actuator interfaced through an AUTOPULSE Control System. This actuator can be used in hazardous environments where the ambient tem- perature range is between 0 OF to 130 OF (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. The actuator specifications are: Nominal Rated Voltage Voltage Minimum Maximum 12 VDC @ 0.57 amps 12.0 VDC 14.0 VDC In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. A reset tool is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical conduit hookup. Shipping Assembly Part No. Description 73327 HF electric actuator 75433 HF Reset Tool Description The Booster Actuator, Part No. 428949, is used when electric actua- tion is required on the selector valve or the CV-98 cylinder valve. The actuator mounts directly to the com- ponent and then a HF electric actua- tor mounts to the top of the booster actuator. The Booster Actuator requires reset- ting after actuation. A Reset Tool, Part No. 429847, is available for this use. Component Material Thread Size/Type Approvals HF Electric Body: 1/2 in. UL(EX-4510); Actuator Brass Straight Listed for use Plunger: Female with FM Stainless Approved Steel systems two I Fire Protection Products One Stanton Street Marinette, WI 54143-2542 +1-715-735-7411 www.ansul.com Copyright © 2012 Tyco Fire Products I.P. All rights reserved. Form No. F-99025-03 I I I I I I I I I ANSUL® JU.IANS7UL. A Tyco International Company Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. 1 1/4-18 UNEF 11/8-18 UNEF System Components UL EX-4510 11-1-00 Page 1-3.6 Booster Actuator The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. I 006037 ANSUL and INERGEN are trademarks of Ansul Incorporated or Its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-2001066 ©2001 Ansul Incorporated t ANSUL® hekSy.t.ma Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote manual pull station, the pull station must contain the com- ponents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. Four actuators are available. Each is designed for a specific component. Add 1 9116 in. (3.9 cm) to height when lever is in the straight up position. System Components UL EX-4510 2-1-12 Page 1-4.1 REV. 5 Lever Release Actuator Component Material Approvals All Manual Brass with UL Listed (EX-4510); Cable-pull Stainless Listed for use with Actuators Steel Pin FM Approved systems Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 '1 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the 1 in. and 2 in. selector valves. Mounts directly to pressure operated stackable actuator for 1 in. and 2 in. selector valves. Actuator has the handle painted red. tqco Fire Protection One Stanton Street +1-715-735-7411 Products Marinette, WI 54143-2542 www.ansuLcom Copyright © 2012 Tyco Fire Products I.P. All rights reserved. Form No. F-9879-05 ANSUL® Ineri CI.an Sy.t.m. Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft (5.5 m) of 1/2 in. Sch. 40 pipe. System Components UL EX-4510 2-1-12 Page 1-12 REV. 6 Flexible Discharge Bend Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer Component Material Thread Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to mate 1/2 in. NPT Male UL Listed (EX-4510); Discharge Bend Type AT mate with CV90 Listed for use with FM Approved and CV-98 Valve systems 187/BIN. FEMALE ADAPTOR (47.9 cm) (BRASS) 1/2 IN. NPT WASHER MALE COUPLING CHECK SWAGEON VALVE END -__._I.f!1 ffirnint" MANIFOLD/END 000808 tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansuI.com All rights reserved. Form No. F-9306-08 ANSUL® Systems Description The header vent plug is used to release low pressure build- up that may occur in a closed system utilizing selector valves or check valves. The header vent plug should also be installed on the cylinder sides of the check valves on both main and reserve systems to relieve any pressure that may leak past the check valve and accidentally actuate the reserve system while the main system is discharging. A header vent plug must be installed in all closed sec- tions of the system manifold(s). The omission of a head- er vent plug may cause the manifold to build pressure. This could result in the actuation of a system cylinder, which would then cause all cylinders in that specific sys- tem to actuate. System Components UL EX-4510 2-1-12 Page 1-14 REV. 3 Header Vent Plug Shipping Assembly Part No. Description 40309 Header vent plug Component Material Thread Size/Type Approvals Vent Plug Body: 1/2 in. NPT Male UL Listed (EX-4510); Brass Listed for use with FM Approved systems Spring: Bronze Seal: Neoprene STEM SPRING BODY CHECK SEAL WAS CHECK CUP 29/32 IN. 1/2 IN. NPT 7/8 IN. (23 mm) (22 mm) 000707 tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansul.com All rights reserved. Form No. F-9334-05 ANSUL® Llkw@n Systems System Components UL EX-4510 2-1-12 Page 1-15 REV. 8 Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. a DIRECTI OF FLOI VISIBLE ORIFICE IDENTIFICATION 002197 Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer/ Body: Forged 1/2,3/4,1, UL Listed (EX-4510); Union Steel 1 1/4,1 1/2, Listed for use with FM Approved systems 2 in. NPT Orifice Plate: Stainless Steel Note: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. Orifice diameter must be specified when placing order. tqco Fire Protection One Stanton Street +1-715-735-7411 Products Marinette, WI 54143-2542 www.ansuI.com Copyright @ 2012 Tyco Fire Products LP. All rights reserved. Form No. F-9311-10 ANSUL® Syat.m. - Lqw-_ Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 1800 nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8, 1/2, 3/4,11, 1 1/4,1 1/2, 2, 2 1/2,3 NPT System Components UL EX-4510 11-1-00 Pagel-16.1 REV. 2 1800 Discharge Nozzle Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 11/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle Size A-in. B-In. C-In. 1/4 in. 5/8 1 9/16 21/32 3/8 in. 3/4 15/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 11/8 25/32 7/8 1 in. 113/32 29/16 1 1 1/4 in. 13/4 23/4 1 1/16 11/2 in. 2 231/32 11/16 21n. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 11/4 NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. 4 A 002743 * Orifice diameter must be Specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Afoul Incorporated or its affiliates. rt'co SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-99020-1 ©2001 Afoul Incorporated I I I I I I I I I I System Components ANSUL® UL EX-4510 2-1-12 Page 1-16.2 lAcc2crU REV. 2 Sy.t.m. Nozzle Deflector Shield Description The INERGEN® system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. The deflector shield helps keep the agent discharge away from false ceiling tiles and fragile light fixtures, avoiding damage to them. Tk -J ..4.-..J and I uI UIILUI IIIIU 0W LUIItI Ut.LU IJI (I OIIU poiiiieu with a cameo cream colored paint. They are available in five sizes. I I I I I Material Approvals Nozzle Steel UL Listed (EX-4510); Deflector Listed for use with Shield FM Approved systems Shipping Assembly Part No. A Inlet NPT B Length of Coupling C Overall Length D Deflector O.D. E Coupling O.D. 417708 1/2 in. 17/8in. 3m. 33/Bin. 1 1/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2 in. 3 1/4 in. 33/8 in. 1 3/8 in. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) 417714 un. 23/8in. 313/l6in. 47/8in. 13/4in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 1 1/4 in. 25/8in. 43/l6in. 47/8in. 21/4in. (6.7 cm) (10.6 cm) (12.4 cm) (5.7 cm) 417720 11/2 in. 31/8 in. 429/32 in. 521/32 in. 21/2 in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) NOTE: There are no deflector shields available for the 2, 2 112, or 3 in, models. '-E--ø- A I C 003651 13 tqco Fire Protection One Stanton Street +1-715-735-7411 Products Marinette, WI 54143-2542 www.ansuI.com Copyright 0 2012 Tyco Fire Products LP. All rights reserved. Form No. F-94152-03 I ANSUL® System Components UL EX-4510 2-1-12 Page 1-17 lnw(m REV. 9 ystems Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing com- ponents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coat- ing. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel UL Listed (EX-4510); Listed for use with FM Approved systems I I I Shipping Assembly Part No. Description 845120 200 ft3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft3 (9.9 m3), 425 ft3 (12.0 m3), 435 ft3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft3 (9.9 m3), 425 ft3 (12.0 m3), 435 ft3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 79638 Back frame assembly (2 cylinder) 79639 Back frame assembly (3 cylinder) 79640 Back frame assembly (4 cylinder) 79641 Back frame assembly (5 cylinder) 79642 Back frame assembly (6 cylinder) 73257 Upright, for 200, 250, 350, and 435 0 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 0 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 0 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft3 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 2418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 0 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft3 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft3 (9.9 m3) and 425 ft3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft3 (12.3 m3) cylinders) 73091 Cylinder clamp (2 cylinders) 73092 Cylinder clamp (3 cylinders) 71683 Weigh rail support - single row 71682 Weigh rail support - double row 71684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row I I I I I I I I I I I I I I I I I I I I I I I I Multi-Cylinder Single Cylinder UPRIGHT WEIGH 7RAIL SUPPORT I I J f \l II I BACK FRAME CYLINDER CLAMP ( • I I II I II I II CARRIAGE BOLT I I I I I WITH NUT I II II I II I II II I /j CLAMP I ii I II I RIGHT II Ij I I BRACKET FOOT CHANNEL II II ii Ii -) LEFT BRACKET FOOT two Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Products Marinette, WI 54143-2542 www.ansut.com All rights reserved. Form No. F-9309-09 I I&I *I bulletin - A Job IiorjWCM?pany One Stanton Set Mannettea, WI 64143-2542 wwwansul.com Bulletin No. 5849 DATE: June 8, 2012 TO: All Authorized ANSUL System Distributors FROM: Product Management - Engineered Systems SUBJECT: New Discharge Pressure Switch Introduction DESCRIPTION We are pleased to anno)t'ie new, improved Discharge Pressure Switch (Part No. 437900)Ttte switch features a redesigned housing and face plate. The new housing provides two options for conduit inlet sizes - the standard 3/4 in. and the new 1/2 in. size. The new face plate/plunger assembly design saves time during maintenance by allowing the switch to be tested without removing the cover. This feature also maintains the integrity of the switch by eliminating the exposure to environmental factors. The switch is three pole, double throw (3PDT) allowing for multiple connections and switching capabilities, and providng versatility and flexibility in the installation process. The pressure switch is operated by the system agent pressure when the system is discharged. The pressure switch can be used to open or dose electrical circuits to shut down equipment (single or 3-phase), turn on lights or alarms, or provide pressure switch feedback to an AUTOPULSE control panel. The housing is constructed of 16 ga. steel, painted red, and is rated 1P65 for dust and water ingress. The 3/8 in. NPT brass pressure inlet is used to connect the pressure switch to the suppression system. Minimum operating pressure is 50 psi (3.5 bar). Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch - Switch: Nickel-plated Conduit Inlets: 314 10A, 250 VAC UL Listed 3PDT Brass in. and 1f2 in. 15A, 125 VAC Listed for use with Housing/Cover: C.R. Pressure Inlet 3/4 HP, 250 VAC FM Approved 16 ga steel in. NPT Female systems Plunger: Stainless 1-, 2-, and 3-phase Steel Pressure Port: I C37700 Brass UL EX-2968 (High Pressure CO2) I UL EX-4510 (IN ERG EN, SAPPHIRE) Main Telephone Numbers: 1-8X).2.6785 or 1-715-735-7415 Customer Service3: Pre 2 Technical services: Prs 4• Training Services: Prs 6• Quality Assurance: Press8 Uterature Fax Orders: 1-0O543-92or 1-715-732.3474 I ANSUL® hwIl-w- System Components UL EX-4510 2-1-12 Page 1-23 REV. 2 Warning Plate - Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (.64 cm) UL Listed (EX-4510); Listed for use with FM Approved systems 12.00 WHEN ALARM SOUNDS VACATE AT ONCE INERGEN® AGENT BEING RELEASED LkeF@ui systems LABEL NO. 416265 002748 tqco Fire Protection One Stanton Street +1-715-735-7411 Copyright © 2012 Tyco Fire Products LP. Alt rights reserved. Products Marinette, WI 54143-2542 www.ansuI.com Form No. F-9315-04 7.00 I ANSUL System Components e 1-24 I UL EX-4510 2-1-12 Page 1-24 Warning Plate - Outside Room Without Alarm 1 Description The warning plate is available for mounting outside the hazard area to warn the personnel that the space is pro- tected by an INERGEN® system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room I Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (.56 cm) UL Listed (EX-4510); Listed for use with FM Approved systems 8.00 WARNING THIS SPACE IS PROTECTED BYAN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. LfRIV(~-)E 99ms LABEL NO. 416266 002747 two Fire Protection One Stanton Street +1-715-735-7411 Products Marinette, Wi 54143-2542 www.ansut.com Copyright © 2012 Tyco Fire Products LP. All rights reserved. Form No. F-9314-05 7.00 BLANK PAGE ANSUL ANSUL INCORPORATED INERGEN MATERIAL SAFETY DATA SHEET ® MARINETIE, WI 54143-2542 CONFORMS TO DIRECTIVE 2001/58/EC IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING 1.1. Identification of the preparation Product Name: "INERGEN" Chemical Name: N/A - This is a mixture/preparation. CAS No.: N/A - This is a mixture/preparation. Chemical Formula: N/A - This is a mixture/preparation. EINECS Number: N/A - This is a mixture/preparation. 1.2. Use of the preparation The intended or recommended use of this preparation is to discharge a FIRE EXTINGUISHING AGENT. 1.3. Company Identification Manufacturer/Supplier: ANSUL INCORPORATED Address: One Stanton Street, Marinette, WI 54143-2542 Prepared by: Safety and Health Department Phone: 715-735-7411 Internet/Home Page: http://www.ansul.com Date of Issue: September, 2004 1.4. Emergency telephone CHEMTREC 800-424-9300 or 703-527-3887 COMPOSITION/iNFORMATION ON INGREDIENTS I 2.1. Ingredient Name: Nitrogen. Chemical Formula: N2. CAS No.: 7727-37-9. EINECS Number: I 231-783-9. Concentration, Wt %: 42.5% Hazard Identification: See Heading 3. I Ingredient Name: Argon. Chemical Formula: Ar. CAS No.: 7440-37-1. EINECS Number: 231-147-0. Concentration, Wt %: I 47 %. Hazard Identification: See Heading 3. Ingredient Name: Carbon Dioxide. Chemical Formula: I CO2. CAS No.: 124-38-9. EINECS Number: 204-696-9. Concentration, Wt %: 10.5 %. I Hazard Identification: See Heading 3. I 3. HAZARDS IDENTIFICATION FOR HUMANS: Product: EU Classification: Nonflammable Gas. A Phrases: I None. S Phrases 9 Keep container in a well ventilated place. Limit Values for Exposure: Nitrogen: None established. Argon: I None established. Carbon Dioxide: OSHA PEL: 5,000 ppm. ACGIH TIV-TWA: 5,000 ppm. I ACGIH TLV-STEL: 30,000 ppm. I IDLH (Immediately Dangerous for Life and Health): 50,000 ppm. Neither this preparation nor the substances contained in it have been listed as carcinogenic by National Toxicology I I INERGEN (Continued) Page 2 I Program, IARC, or SIGNS AND SYMPTOMS: I Acute Exposure: Eye Contact: Non-irritating gas. Skin Contact: Non-irritating gas. Inhalation: Vapor is heavier than air and can cause suffocation by reducing oxygen available for breathing. Breathing very high concentrations of vapor can cause lightheadedness, giddiness, shortness of I breath, muscular tremors, and weakness, acrocyanosis. Also unconsciousness or even death. Ingestion: Non-irritating gas. Not a likely route of entry. Chronic Overexposure: No data available. I MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: None known. FOR ENVIRONMENT: Carbon dioxide is a global warming gas. FIRST AID MEASURES Eye Contact: Immediately flush eyes with water for a minimum of 15 minutes. If redness, itching or a burning sensa- tion develops, get medical attention. Treat for frostbite if necessary. Skin Contact: If redness, itching or a burning sensation develops, get medical attention. Treat for frostbite if neces- sary. Inhalation: Remove victim to fresh air. If cough or other respiratory symptoms occur, consult medical personnel. If I not breathing, give artificial respiration, preferably mouth-to-mouth. If breathing is difficult, give oxygen. Consult medical personnel. Ingestion: None needed. FIRE-FIGHTING MEASURES Non-flammable gas. Use agent appropriate to surrounding material. I Though gas cylinders are equipped with pressure and temperature relief devices, they should be removed from high temperature areas or fires, if safe to do so, to avoid risk of rupture. There are NO extinguishing media which must not be used for safety reasons. I NO special protective equipment is needed for fire-fighters. Wear protective equipment appropriate for the fire conditions. ACCIDENTAL RELEASE MEASURES I For personal protection: Prevent direct skin and eye contact, see Heading 8. Clean up: This substance will vaporize into the atmosphere, see Heading 13. Carbon dioxide is a global warming gas. HANDLING AND STORAGE I 7.1. Handling Care should be taken in handling all chemical substances and preparations. Secure to prevent falling. Do not move without safety cap in place to prevent damage to valve. See incompatibility information in Heading 10. 7.2. Storage Store cylinders with restraints to prevent possibility of rupture. Store as a compressed gas in DOT-approved vessels. Keep safety cap in place while in storage. I See incompatibility information in Heading 10. Store in original container. Keep tightly closed until used. Carbon Dioxide is a global warming gas. I 7.3. Specific use The intended or recommended use of this preparation is to discharge a FIRE EXTINGUISHING AGENT. INERGEN (Continued) Page 3 EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1. Exposure limit values Limit Values for Exposure: Nitrogen: None established. Argon: None established. Carbon dioxide: OSHA PEL: 5,000 ppm, (9,000 Mg/M3). ACGIH TLV-TWA: 5,000 ppm, (9,000 mg/m3). ACGIH TLV-STEL: 30,000 ppm, (54,000 mg/M3). IDLH (Immediately Dangerous for Life and Health): 50,000 ppm. 8.2. Exposure controls 8.2.1. Occupational exposure controls 8.2.1.1. Respiratory protection Exposure to high concentrations requires the use of self-contained breathing apparatus. Other respirators will not protect in an oxygen deficient atmosphere. 8.2.1.2. Hand protection Use leather gloves when handling cylinders. 8.2.1.3. Eye protection Use safety glasses with side shields or safety goggles. 8.2.1.4. Skin protection No special equipment is needed. 8.2.2. Environmental exposure controls None needed. The components of this product are normal atmospheric gases. PHYSICAL AND CHEMICAL PROPERTIES - - 9.1. General information I Appearance: Colorless gas. Odor: None. 9.2. Important health, safety, and environmental information pH: 7 (at 25°C). Boiling point/boiling range: —320 °C. Flash point: None to boiling. Flammability (solid/gas): Not flammable. Explosive properties: Not explosive. Oxidizing properties: Not an oxidizer. Vapor Pressure: 2205 psi © 70°F. (21.1 °C) Relative Density (Water = 1): 0.084 lbs/ft3. Solubility: - Water solubility: Carbon dioxide: 88 ml per 100 ml @ 20 °C. - Fat solubility: Partition coefficient, n-octanol/water: Viscosity: Vapor density (Air = 1): Evaporation rate (Butyl acetate = 1): 9.3. Other Information Auto-ignition temperature Nitrogen: Insoluble. Argon: Insoluble. Not soluble. Not determined. Not determined. 1.0. <1, water only evaporates. Does not ignite. INERGEN (Continued) Page 4 STABILITY AND REACTIVITY 10.1. Conditions to avoid Extremely high temperatures, as in a fire may cause a cylinder to fail. There are NO known conditions such as temperature, pressure, light, shock, etc., which may cause a dangerous reaction. 10.2. Materials to avoid Because of Carbon Dioxide: (Al + Na202), (Mg + Na2O), Cs20, Li, K, Mg(C2H5)2, KC21-1, Na, NaK, and Ti. 10.3. Hazardous decomposition products Normally stable. Hazardous polymerization will NOT occur. There are no hazardous combustion or decomposition products. TOXICOLOGICAL INFORMATION Carbon dioxide: Inhalation LCLO (human) = 100,000 ppm/mm. Can cause suffocation by reducing oxygen available for breathing. Breathing very high concentrations of vapor can cause dizziness, shortness of breath, unconsciousness, or even death. ECOLOGICAL INFORMATION 12.1. Ecotoxlcity This preparation consists of normal atmospheric gases. 12.2. Mobility This preparation consists of normal atmospheric gases. 12.3. Persistence and degradability This preparation consists of normal atmospheric gases. 12.4. Bioaccumulative potential This preparation consists of normal atmospheric gases. 12.5. Other adverse effects Ozone depletion potential: None. Photochemical ozone creation potential: None. Global warming potential: Carbon dioxide is a global warming gas. DISPOSAL CONSIDERATIONS Carbon dioxide is a global warming gas. This preparation consists of normal atmospheric gases. TRANSPORT INFORMATION Hazard Class or Division: Compressed Gas N.O.S. (Mixture of compressed nitrogen, argon, and carbon dioxide), Class 2.2, UN1956. Label: Nonflammable gas. Emergency response guide page number: 126; EMS (Intl): 2-04. For additional transport information, contact Ansul Incorporated. Carbon dioxide is a global warming gas. I INERGEN (Continued) Page 5 15. REGULATORY INFORMATION EU Classification: Nonflammable gas. R Phrases: ' None. S Phrases: 9 Keep container in a well ventilated place. Exposure Limit Values: Nitrogen: None established. Argon: None established. Carbon dioxide: OSHA PEL: I 5,000 ppm, (9,000 mg/m3). ACGIH TLV-TWA: 5,000 ppm, (9,000 Mg/M3). ACGIH TLV-STEL: 30,000 ppm, (54,000 Mg/M3). IDLH (Immediately Dangerous for Life and Health): 50,000 ppm. EINECS Status: All components are included in EINECS inventories or are exempt from listing. I EPA TSCA Status All components are included in TSCA inventories or are exempt from listing. Canadian DSL (Domestic Substances List): All components are included in the DSL or are exempt from listing. Environmental restrictions: None are known. Restrictions on Marketing and Use: None are known. I Refer to any other national measures that may be relevant. 16. OTHER INFORMATION (HMIS) HAZARDOUS MATERIAL IDENTIFICATION SYSTEM RATINGS: HEALTH: 1 4. Severe Hazard FLAMMABILITY: 0 3. Serious Hazard REACTIVITY: 0 2. Moderate Hazard 1. Slight Hazard 0. Minimal Hazard (WHMIS) CANADIAN WORKPLACE HAZARDOUS MATERIAL IDENTIFICATION SYSTEM RATINGS: This product is rated: A Compressed Gas. Format is from directive 2001/58/EC. EINECS data is from http://ecb.jrc.it/existing-chemicals/ Data used to compile the data sheet is from Ansul Material Safety Data Sheet, February, 2002. Toxicological information added from the EINECS ESIS (Existing Substances Information System). A rating under WHMIS has been added, following the Canadian guidelines. I 17. DISCLAIMER THE ABOVE INFORMATION IS BELIEVED TO BE CORRECT, BUT DOES NOT PURPORT TO BE ALL INCLUSIVE AND SHALL BE USED ONLY AS A GUIDE. ANSUL SHALL NOT BE HELD LIABLE FOR ANY DAMAGE RESULTING FROM HANDLING OR FROM CONTACT WITH THE ABOVE PRODUCT. I I I MSDS available at http://www.ansul.com ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINErTE, Wi 54143-2542 715-735-7411 Form No. F-97594 02004 Ansul Incorporated Litho in U.S.A. I INERGEN SYSTEM I DETECTION & CONTROL COMPONENTS BLANK PAGE • AUTOPULSE Z-10 AGENT RELEASE CONTROL PANEL Or kThIi Data/Specifications I .. 1. •• •• Agent Release Control Panel designed specifically for suppression release operation with: a Four initiating device circuits (lDCs) a Two notification appliance circuits (NACs) a Two release appliance circuits (RACs) a Two special purpose monitor inputs (SPMs) for manual release request and manual abort request a Three auxiliary relays with selectable functions a Easily selected activity timing options Agent release operation includes: a Automatic extinguishing release a Deluge and preaction sprinkler system release a Dual or single hazard area protection a Combined agent release and preaction operation* o lDCs are selectable for cross-zoning or for activation from a single detection input , a Short circuit RAC supervision Operator interface provides: a Status LEDs per circuit for Alarm, Trouble, and Supervisory (where appropriate) a Acknowledge, alarm silence, and system reset a Operating mode and timer selection when in programming mode Audible Escalation of Events: a Single Audible Appliance Tone: Stage 1 activates Temporal or 20 bpm March Time pattern; Stage 2 activates 120 bpm March Time pattern to indicate release timer active; Release activates On Steady to indi- cate release timer expired and actuator is activated a Dual Audible Appliance Control* (Single Hazard): RAC 2 provides a third NAC for dedicated Stage 1 Bell control; NACs 1 & 2 indicate release as On Steady Compatible with Listed/Approved 24 VDC coil automatic water control valves Required system components: a Coil supervision module, Part No. 430687, one per solenoid control RAC a Maintenance Switch, Part No. 433936 or 433937, one per solenoid control RAC Recommended accessory (where appropriate): a Abort Switch: - Part No. 433940, Flush Mount 01 * Requires software revision 401 or higher ---------------------------- AGENT DISCHARGE PATH CYLINDER VALVE AGENT ACTUATOR SOURCE CIRCUIT coiL SUPERVISORY MODULE ---- MAINTENANCE ----ø. SWITCH ©=o SPM1 RAC RAC2 NAC 1 Ej tiCs 2, 3___:-.t 006554 AUTOPULSE Z-10 Agent Release Control Panel One-Line System Reference Drawing Dedicated for Agent Release: AUTOPULSE® Z-10 Suppression Release Panels provide conventional fire alarm control circuits and are equipped with the features required for a wide variety of single or dual hazard suppression release applications. Capabilities include automatic extinguishing agent release and deluge and preaction sprinkler control. Flexible i/O Capabilities: Four lDCs allow for either four separately monitored zones or two, cross-zoned connections. Two SPMs allow P. dedicated manual inputs for release or abort. Two releasing appliance circuits (RACs) supervise to the actuator coils and activate the actuators when required. The two NACs and the three panel auxiliary relays P- provide status condition information. Easy Program Selections: The operator panel has a program mode that allows selection of panel operation type and detailed operating selections using an easily selected sequential programming operation. History Log: The last 50 events are stored in non-volatile memory. This information is accessed by connecting a technician's computer to the service port which is also used to set the date and time. Operator Panel: The operator panel has alarm and trouble status indi- cating LEDs for each input and output, visible through the locking cabinet door. Unlocking the door provides access to the Acknowledge, Alarm Silence, and System Reset push-button switches. Four Class B lDCs provide coverage for either two cross-zoned areas or four separately zoned areas. lDCs are capable of supporting up to 30 current-limited smoke detectors or electronic heat detectors as well as manual stations and other compatible contact closure initiating devices. lDCs are capable of Class A operation with an optional adapter module and can be programmed as Class C (short or open initiates a trouble) for use with current limited devices only. Single hazard agent release P. applications monitor low pressure switches on 1DC3 and tamper switches with lDC4. Preaction Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is maintained in the pipe. Operation requires both an activated sprinkler head and an activated fire alarm initiating device. Combined Agent Release and Preaction Systems provides agent release and preaction control. (Available with software revision 4.01 or higher.) For applications where agent release may not be sufficient for fire control, sprinklers are put in preaction mode to allow waterflow to continue the fire response. (Preaction is assumed, selected deluge could be provided, determined by the sprinkler installation, panel opera- tion is the same.) UL requirements for Fire Alarm Systems Listed for Automatic Release or Deluge and Preaction Sprinkler Systems are the same as described above for Automatic Extinguishing Release Systems. FM Approved requirements for Fire Alarm Systems for Automatic Release of Deluge and Preaction Sprinkler Systems require operation of specific compatible FM Approved Automatic Water Control Valves, a minimum secondary power capacity of 90 hours, and all circuits for the automatic release initiating devices must be capable of operation during a single open circuit fault condition (Class A). RELEASE CONTROL PANEL Part No. Description Reference 430525 Basic Releasing Panel, Includes: Four lDCs, two operates with AC input of: NACs, two SPMs, two 120/220/230/240 VAC, RACs, 3 A power supply 50/60 Hz (auto-select) with battery charger, cabinet and door EXPANSION MODULES Part No. Description Reference 430529 Auxiliary Relay Module; four Two I relays, Form C, rated 7 A @ maximum 12O VAC, 5A@3OVDC, unsupervised contacts Select as required 430531 Two Circuit Class A Adapter Four Module for lDCs, SPMs, maximum or NACs Batteries Part No. Description Reference 417692 7.0 AH Battery Pack, 24 VDC Select one battery shipping assembly per 417693 12 AH Battery Pack 24 VDC system standby requirements; two batteries are included 417694 17 AH Battery Pack, 24 VCD Requires external battery cabinet 417695 25 AH Battery Pack, 24 VDC Release Control System Modules Part No. I Description 430687 Coil Supervision Module, one required per RAC; C936 refer to pages 6 and 7 for detail Maintenance Switch, one required per RAC or 433937 433940 Abort Switch 431196 Abort Supervision Module Qf) TWo Class B Special Purpose Monitoring Circuits (SPMs) are dedi- cated for manual release or abort, waterfiow and supervisory, or release/abort and pressure, depending on system type. Inputs are normally open switches. An abort switch stops release while activated and upon deactivation, the release operation occurs after a selectable time delay. Manual release inputs override abort switches and activate the release after selectable delays of from 0 to 30 seconds in 5 second increments. For Dual Hazard applications, current limited abort operation is required. SPMs are programmable as Style C and capable of Class A operation with the optional adapter module. TWo Class B NACs are provided for reverse polarity, notification appli- ance operation, each rated 2 A. Class A operation is available with the optional adapter module. NAC operation is selectable per application. TWo Class B Release Appliance Circuits (RACs): Rated 2 A each, these circuits are dedicated to operating release control actuators. RAC cutout timing is selectable as no cutout, 45 seconds, or 1 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes. For bell/hom/strobe single hazard appli- cations, RAC 2 functions as a third NAC (NAC 3). Auxiliary Power Output: Rated at 750 mA, this output can be wired as continuous or as resettable. Resettable is normally used to power 4-wire smoke detectors. Standard Auxiliary Relay Outputs: Three relays outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC. Touble Relay (Aux Relay 1) is energized when Normal and is de-ener- gized with a Trouble condition. For Single Hazard Operation: Aux Relay 2 is the Alarm relay and Aux Relay 3 indicates Time Delay Started or can optionally be selected as a Supervisory relay. For Dual Hazard Operation: Aux Relay 2 is for Hazard Area 1 Alarm;) Aux Relay 3 is for Hazard Area 2 Alarm. f Power Supply and Battery Charger: During alarm, the power supply provides 3 A at 25.5 VDC, filtered and regulated. The temperature compensated battery charger provides 27.5 VDC for charging batteries suitable for up to 90 hour standby and 10 minutes of alarm. External battery chargers and cabinets can be used for more battery backup. I Automatic Agent Release Systems: These systems automatically acti- vate solenoid control valves for the release of a fire extinguishing agent in response to fire detection device input. Automatic Extinguishing Release Systems with Separate Bell Control (single hazard) (SW rev. 4.01 or higher). RAC 2 operates as a bell control NAC. When cross-zoned, stage 1 alarm activates the bell until the release timer starts. When not cross-zoned, stage 1 alarm acti- vates the bell until expiration of the release timer. In both cross-zoned and non cross-zoned applications, NAC2 may be programmed to indi- cate either a tamper switch supervisory condition or the start of the release timer using a cadence pattern operation. UL and FM Extinguishing Release System Panels must have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Actuators must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil super- vision. Deluge and Preaction Sprinkler Systems automatically activate water control valves in response to fire detection device input. Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control valve. They are used to deliver water simultaneously through all of the open sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. 12 FM Group Manufacturer del Number 7LV2LBX25 Details A Skinner 24 VDC, 11 W, 458 mA, 1/2 in NPS, 1/2 in orifice B ASCO 8210A107 24 VDC, 16.8W, 700 mA, 1/2 in NPS, 5/8 in orifice R8210A107 8210A107 C Star Sprinkler 5550 24 VDC, part of Model 0 deluge valve D ASCO 8210G207 24 VDC, 10.6W, 440 mA, 1/2 in NPS, 1/2 in orifice V2648571, N.C. HV2648581 N.O. E Skinner 73218BN4UNLVNOC111C2 24 VDC, 10W, 420 mA, 1/2 in NPS, 5/8 in orifice 73212BN4TN00N0C111C2 24 VDC, 10W, 420 mA, 1/2 in NPS, 5/8 in orifice; 5-300 psi rated working pressure F Skinner 73212BN4TNLVN0C322C2 24 VDC, 22W, 1/2 in NPS, 920 mA, 250 psi (1725 kPa),1/2 in orifice G Skinner 71395SN2ENJ1NOH111C2 24 VDC, 10W, 420 mA, 1/4 in NPS, 1/16 in orifice, 250 psi (1725 kPa) rated working pressure H 'liking HV-274.060-001 24 VDC, 22.6W, 940 mA, 1/2 in NPS, 250 PSI (1725 kPa), 3/4 in orifice Power Ratings Wr Input AC I Voltage Ratings Current Ratings 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select 2 A maximum @ 120 VAC input; 1 A maximum @ 240 VAC input Power Supply Output 3 A maximum available for external loads Battery Charger Temperature compensated, capable of recharging batteries required for 90 hour standby and 10 minute alarm (contingent on auxiliary power load) Standby Current 100 mA; with lDCs fully loaded, tone-alert silenced, trouble LED on, charger off Alarm Current 264 mA + external loads; (2 zones in alarm & 2 internal relays, NACs and RACs on) Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum; see NAC ratings for details) Initiating Device Circuits (lDCs) Supervisory Alarm Current Output Voltage Capacity 3 mA maximum; 3.3 kQ end-of-line resistor per circuit 75 mA maximum 28 VDC maximum Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required; wiring distance is limited to 50 12 maximum Application Special Purpose Monitoring Circuits For Dual Hazard Applications (SPMs) Supervisory Activated Output Voltage For Manual Release, Abort Switches, or Supervisory functions only; not for detectors; wiring distance is limited to 50 12 maximum Dual Hazard Application Abort Switches require a current limiting resistor of 1.2 kL, 1 W, or an external Abort Supervision Module per SPM 6 mA; 3.3 W end-of-line resistor per circuit 75 mA maximum 28 VDC maximum Notification Appliance Alarm Current Circuits (NACs) Output Voltage Synchronized Strobe Operation Special Application appliance rating = 2 A maximum on a NAC NOTE: Special Application appliance rating = full 3 A power supply rating Regulated 24 DC appliance power = 1.5 A maximum on a circuit NOTE: Regulated 24 DC strobe load = 1.35 A maximum total for power supply Alarm = 26 VDC max.; supervisory = 29 VDC maximum; 10 kQ end-of-line resistor Requires NAC dedicated to strobe control with non-coded output; use an external Synch Module; up to 33 strobes can be synchronized per Z-10 Notification Appliance Reference Regulated 24 DC Appliances Power for other appliances listed to UL Standard 1971 or UL Standard 464; use associated external synchronization modules where required Output Current 2 A maximum per circuit Release Appliance Circuits (RACs) Output Voltage Activated = 26 VDC maximum; non-alarm = 29 VDC maximum; 10 42 end-of-line resistor Auxiliary Power Output; for Special Application loads only Two outputs are available, continuous operation or resettable operation; combined output is 750 mA maximum; output voltage = 19.25 to 27 VDC Auxiliary Relay Outputs (Trouble, Aux Relay 2, Aux Relay 3) Contacts rated 2 A @ 30 VDC, 0.35 p.f., inductive, selectable as N.O. or N.C. by jumper Wiring Connections for Above and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Auxiliary Module Ratings Class A Adapter Module 430531 Two circuits per module, rated same as circuits; not applicable to RACs (no additional current required) Auxiliary Relay Module 430529 Relay Type AC Ratings DC Ratings Four relays with two outputs per relay; individually selectable as N.O. or N.C. 7 A @ 120 VAC, resistive 5 A © 30 VDC, 0.35 power factor, inductive Auxiliary Module Ratings (Continued) Auxiliary Relay Module Module Current 430529 (Continued) Wiling 12 mA standby; 70 mA with all four relays energized; © 24 VDC Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Coil Supervision Module Construction Epoxy encapsulated Dimensions 1-3/8 in. W x 2-7/16 in, Lx 1-1/16 in. H (34 mm x 62 mm x 27 mm) Wiring 18 AWG (0.82 mm2) wire leads, color coded Coil Supervision Module Current Rating 2 A maximum; internally fused at 3 A, non-replaceable Environmental Ratings Operating Temperature Range 32 OF to 120 °F (0 °C to 49 °C) Operating Humidity Range up to 93% RH, non-condensing © 100.4 °F (38 °C) maximum Part No. Type Component Sheet 430559 430562 LiFEalarm® Photoelectric Detector 2.80/./ft Obscuration (Standard) LiFEalarm® Photoelectric Detector 3.501./ft Obscuration T-2007153 430565 135° F (57°C) Fixed Heat Detector T-2007159 430566 200° F (93°C) Fixed with Rate-of-Rise Heat Detector T-2007159 NOTE: For proper detector bases, refer to Component Sheet 1-2007153, I Wm I LISTED/APPROVED ACTUATOR OR DELUGE AND CA)A--~ PREACTION AUTOMATIC WATER CONTROL VALVE; ONE IF-24 VDC (OR 2 IN SERIES IF 12 VDC) PER RAC - ACTUATOR WIRING JUNCTION Box Yel BIk COIL SUPERVISION MODULE Red Blk ABORTSUPERVISIONMODULE - -- I i MAINTENANCE DISCONNECT SWITCH 24 VDC FOR MAINTENANCE DISCONNECT 4::P 4 II STATUS INDICATOR (IF REQUIRED) RAC 2 OPTIONAL STROBE RAC1 I I I SYNCHRONIZATION MODULE TYPICAL STROBE ONLY NAC NAC I 1[J.Ii TYPICAL HORN ONLY NAC NAC 2 ABORT SWITCHES (AS REQUIRED) E4 SPMI - SPM2 DC 1 MANUAL ARE ALARM STATION fegDTIDI DETECTION IDCS 2, 3, AND 4 DEVICES AUTOPULSE Z-10 SUPPRESSION RELEASE PANEL GENERAL WIRING NOTE: WIRING SHOWN IS FOR REFERENCE ONLY, REFER TO SPECIFIC INSTALLATION INSTRUCTIONS FOR DETAILED WIRING INFORMATION. Sequence Select one of 13 Application Modes (numbered 1 through 13) Agent Release Single Hazard Cross-Zoned 1 Combined Release (RACs activate together) Either Zone 2 Dual Hazard Cross-Zoned 3 Independent Release (RACs are separate) Either Zone 4 1 Preaction/Deluge Single Hazard Cross-Zoned 5 Combined Release (RACs activate together) Either Zone 6 Dual Hazard Cross-Zoned 7 Independent Release (RACs are separate) Either Zone 8 Agent Release; Single Hazard Cross-Zoned 9 NYC Abort (not UL listed) Agent Release & Preaction; Single Hazard Cross-Zoned 10 Either Zone 11 RAC 2 provides Preaction Control; RAC 1 is Agent Release Control Agent Release, Bell/Horn/Strobe; Single Hazard Cross-Zoned 12 Either Zone 13 RAC 2 operates as NAC 3 for Stage 1 Bell Control (separate sound from release alarm) Sequence Programming Mode Description Description 2 Select Relay Operation for Application Modes 1-9 Select "Original" operation mode or "Enhanced" mode 3 IDC and SPM Circuit Style Class B/Class A or Style C 4 Automatic Release Time Delay Selectable in 5 second increments from 0 to 60 seconds (default is 60 seconds) 5 RAC Cutout Timer No cutout, 45 seconds, or 1, 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes 6 Manual Release Time Delay 0, 5, 10, 15, 20, 25, or 30 seconds 7 Abort Release Time Delay UL Standard 864 listed Immediate or 10 seconds remaining Not UL Standard 864 listed IRI abort (cross-zoned systems only), NYC abort, or original release delay 8 NAG Coding (where selectable) Temporal pattern or 20 beats per minute (first cross-zone alarm) 9 Standard Operation NAG Operation Pro-Discharge Operation No inhibit or one minute inhibit selected as: both on until silence, NAG 1 on until reset and NAG 2 on until silence, or both on until reset; NOTE: For clean agent release, a pre-discharge NAC must be configured to warn of impending discharge, the release timer selects the duration of the pre-discharged signal 10 Supervisory Latching Latching or non-latching 11 Supervisory Notification LED and tone-alert only, or with: NAG 2 also on; Aux Relay 3 also on; or both NAG 2 and Aux Relay 3 also on RUN MODE: LEDs PROVIDE ALARM (RED) AND TROUBLE (YELLOW) STATUS PER IDC ZONE; ZONE 4 YELLOW LED INDICATES SUPERVISORY STATUS IF STILL FLASHING AFTER ACK PROGRAM MODE: TOP TEN LEDs INDICATE PROGRAMMING MODE CATEGORY ALARM SILENCED YELLOW LED INDICATES THAT AUDIBLE NOTIFICATION APPLIANCES ARE SILENCED PRIOR TO SYSTEM RESET SUPERVISORY AND SYSTEM TROUBLE YELLOW LEDs; FOR UL SYSTEMS, INDICATION OF DISABLED OR DISCONNECTED RAC AC POWER GREEN LED IS ON WITH NORMAL POWER STATUS I C I 0 0 0 0 0 0 0 0 RUN MODE: RED LEDs INDICATE MANUAL RELEASE ACTIVATED (FOR AGENT I RELEASE APPLICATIONS); I YELLOW LEDs INDICATE TROUBLE FOR SPMs (ZONES I 5 and 6). NACs, and RACs, t FOR RACs, YELLOW LED I INDICATES SUPERVISORY IF I . STILL FLASHING AFTER ACK PROGRAM MODE: TOP EIGHT I LEDs PROVIDE I PROGRAMMING SELECTION 0 0 AGENT RELEASED RED LED L,.-.-- INDICATE RACs ARE ACTIVATED 0 I I EARTH FAULT YELLOW LED I INDICATES PRESENCE OF O AN EARTH FAULT ABORT ACTIVE YELLOW LED TRACKS STATE OF ABORT SWITCH RELAY DISCONNECT YELLOW LED INDICATES THAT EXPANSION RELAYS HAVE BEEN DISABLED FOR SERVICE ir LABEL INSERT SELECTABLE FOR PREACTION/DELUGE, AGENT RELEASE, OR COMBINATION AGENT RELEASE/PREACTION DELUGE, UL OR ULC VERSIONS (UL AGENT RELEASE VERSION SHOWN FOR REFERENCE Oani, I Zone ii o rouble J O(lami I Zone 21 oTrouble o Alarm Zone 3i o tTrouble J Qlanii I Zone 4i o rouble 1 J o Alarm Silenced o Supervisory o 1,ysIem Trouble o (Powe) [_Zone 5 Trouble Manual Release) Zone 6 TroubleJ NAG 1 Trouble NAG 2 Trouble RAG 1 Trouble RAG 2 TroubleJ Agent Released Earth Fault Abort Active Relay Disconnect ACK I ALARM I I I I SYSTEM ii 1 11 SILENCE RESET ACK ACKNOWLEDGES STATUS DURING RUN MODE AND ACCEPTS SELECTION DURING PROGRAM MODE; PRESS AND HOLD FOR 5 SECONDS TO PERFORM LAMP TEST ALARM SILENCE SILENCES AUDIBLE ALARMS \ 006552 SYSTEM RESET RESTORES THE SYSTEM TO NORMAL DURING RUN MODE AND TOGGLES THE SELECTION DURING PROGRAM MODE Solenoid valves are connected as 2-wire, Class B notification/ releasing circuits with only one 24 VDC solenoid valve per circuit (or two, 12 VDC solenoids in series if applicable) to ensure supervi- sion. Coil Supervision Module, Part No. 430687, must be wired electri- cally before the solenoid valve and located in the solenoid valve wiring Junction box. For FM Approved Deluge and Preaction Sprinkler operation, initiat- ing device circuits must be Class A, wired to Listed/Approved devices. Power supply loading and wiring distances must be per Installation, Programming, and Operating Instructions, Part No. 430545. For FM Approved Deluge and Preaction Sprinkler Systems, battery standby capacity must be a minimum of 90 hours with 10 minutes of alarm. For FM Approved Automatic Extinguishing Release, battery standby must be a minimum of 24 hours with 5 minutes of alarm. Battery standby must be selected for a minimum voltage of 23 VDC to ensure proper valve operation. Maintenance Switch, Part No. 433936 or 433937, are required to allow the system to be tested or serviced, For FM Approved Deluge and Preaction Sprinkler operation, the specified compatible Automatic Water Control Valves must be used. For UL Listed and FM Approved Automatic Extinguishing Release, solenoid valves must be electrically compatible. Abort Switch, Part No. 433940, is available when abort operation is required. When used, wire on Special Purpose Monitoring Circuits (SPMs) as Class A or B, the same as required for other initiating devices. Manual Release Stations are used for direct activation of the release solenoids with the appropriate time delay implemented by the fire alarm control panel. IiListed: FM Approved: J13012391 H CSFM: 7165-0595:113 MEA (NYC): 49-03-E Auxiliary Relay Module, Part No. 430529. Four relays per module are available as required. Dual hazard applications will require two modules for auxiliary relay operation. Each relay module has a manual discon- nect switch that controls relays 2 through 4 (Trouble Relay is not controlled). Relay outputs are required to be connected to 15 maximum circuit breaker. Operation is per the following actions: Relay 1 activates on any trouble associated with its hazard Relay 2 activates on any alarm associated with its hazard Relay 3 activates for pressure switch as required per application or actu- ates with second zone for cross-zoned systems (hazard specific) Relay 4 activates when the hazard specific RAC activates Dual Circuit Class A Adapter Module, Part No. 430531. This module converts two Class B circuits to Class A operation. It consumes no addi- tional current and is compatible with IDCs, SPMs, and NACs. Up to four modules may be mounted within the AUTOPULSE Z-10 cabinet. Maintenance Switch. Proper service of release appliance circuits requires the ability to securely disconnect the release circuit during installation and maintenance. Maintenance switches are controlled by keyswitch and initiate a supervisory condition when in disconnect/disable position. Models with lamp are on a double-gang plate and are powered from separate 24 VDC wiring. Mounting is on stainless steel plates and models are available as either surface or flush mount (see drawing below). Maintenance switches, one per RAG, are required per NFPA 72, the National Fire Alarm Code, to allow the system to be tested or serviced without actuating the fire suppression systems. Their use may not be allowed in some jurisdictions; always confirm local requirements. When used, maintenance switches are required to ensure that operation initi- ates a supervisory condition. NORMAl. 0 1:; ci . AILIO FIRE SUPPRESSION DISCONNECT! DISABLE [ Pulse Maintenance Switch 00654N Abort Switch. For manual abort requests, these abort switches are available with or without a built-in 1.2 42, 1 W resistor and are mounted on single-gang stainless steel plates. Abort switches are connected to the SPM inputs per system requirements. Activity abort occurs while the switch is pushed and continues after releasing the switch for the selected Abort Release Time Delay (see drawing below). Cl) FIRE SUPPRESSION SYSTEM ABORT 0 PUSH AND HOLD 11) Ptdse Abort Switch .,, 1 .1 BOX WIDTH 14-5/8 IN (372 mm) - - - - TYPICAL CONDUIT ENTRY AREA (CUT HOLES AS REQUIRED) (TOP AND SIDE VIEWS ARE SHOWN WITH DOOR INSTALLED) I II..........I 4 111/4 IN (286 mm) BOX DEPTH 4-1/4 IN (108mm) Class A adapter boards eIay 0 Aux. (ay DOOR e2 THICKNESS - 5/OIN(l6mm) 131/2 IN (Main boar d) = (343mm) I o Lo I __ 16 IN (483 mm) I input I =1 ffr Battery Area (No i conduit or wiring in this area) 131/4 IN (337 mm) (IIIII.._1ii I (FRONT VIEW MODULE PLACEMENT REFERENCE SHOWING NOTE: FOR SEMI-FLUSH MOUNTING, CABINET MOUNTING HOLE DIMENSIONS, OPTIONAL CLASS A ADAPTER MUST EXTEND 1-1/2 IN (38 mm) MODULES, AND OPTIONAL RELAY MODULES) MINIMUM FROM WALL SURFACE NOTE: A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND TRANSIENT PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED, DEDICATED EARTH CONNECTION PER NFPA 70, ARTICLE 250, AND NFPA 780. I EøDbPDINt IWflDMATlCsII ./ . Part No. Description 430525 AUTOPULSE Z-10 FACP, 120/240 VAC NOTE: Proper operation of release control systems requires that the system design, installation, and maintenance be performed correctly and in accordance with all applicable local and national codes, and equipment manufacturer's instructions. No liability for total system operation is assumed or implied. ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or Its affiliates. I loot-IJOSUL0J tqco Ansul Incorporated 715-735-7411 Copyright Al Incorporated Mannette, WI 54143-2542 www.ansul.com Form No. F-2007055-1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I FIRE OFFICE OF THE STATE FIRE MARSHAL ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING SERVICE LISTING No. 7165-0595:0113 Page 1 of I I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: ANSUL FIRE PROTECTIONI Stanton Street, Marinette, WI 54143-2542 Contact: Jim Engman (715) 735-7411 Fax (715) 732-3634 I Email: jengman©tycoint.com DESIGN: Model Autopulse Z-10 (430525) fire alarm control unit. Power limited. Local or releasing service, automatic, manual, waterflow and sprinkler supervisory service. Refer to listee's data I sheet for additional detailed product description and operational considerations. RATING: 120/220 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. I APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm I Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition*. XLF: 7165-0026:0314 I I I I I I I I I *updated 02-08-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I General The NBG-1 2LR is an Agent Release Station designed for use I with AUTOPULSE® Fire Suppression Control Panels. Features Non-coded, dual-action operation I • Made with durable polycarbonate Optional surface backbox I . Dual-action release only Applications The NBG-12LR is ideal for areas such as clean rooms and I computer rooms where a chemical agent is used to extinguish afire. Wiring (+) 2 TO____________________________________________________ MANUAL4 RELEASE II CIRCUIT (—) 008021 * REFER TO CONTROL PANEL MANUAL FOR LISTED ELR Detection and Control Components NBG-12LR Dual-Action Agent Release Station (10-3189 I0-636X-29 542139 542D) I Dimensions, Backboxes ! 41181N. ------------- (10.5 cm) I 5 1/2 IN. (14.0 cm) j 008020 I I I AUTOPULSE Is a trademark of Tyco International (US), Inc. or Its affiliates. I TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 Listings and Approvals UL...........................S692 FM .........................Approved California State Fire Marshall (CS FM). . . . 7150-0028:199 Ordering Information Shipping Weight Part No. Description lb (kg) 435471 NBG-12LR Dual-Action Agent 2 (0.91) Release Station 418990 SB-10 Surface BackBox 0.5 (0.23) for NBG-12LR 3-13.1 Form No. T-2008057 Copyright 02008 Tyco International (US), Inc. I I I 1 318 IN. (3.5 cm) DEEP CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 1 LISTING No. 7150-0595:0119 Page 1 of 1 I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: ANSUL FIRE PROTECTION1 Stanton Street, Marinette, WI 54143-2542 Contact: Jim Engman (715) 735-7411 Fax (715) 732-3634 I Email: jengmantycoint.com DESIGN: Model AP-NBG-I2LR fire alarm pull box with dual action pull station. Model is intended for agent releasing device. Refer to listee's data sheet for detailed product description and I operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control I units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. I Ii I I I ill Updated 09-08-2009 fm I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator I Fire Engineering Division 006564 LiFEalarm Photoelectric Detector Mounted in Base Listings and Approvals UL Listed ULC Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) Specifications Voltage 15 to 32 VDC, from Control Panel IDC Standby Current 100 pA @ 24 VDC - Alarm Current, Up to 86 mA maximum, exact 2-Wire Operation current is determined by alarm current limiting of connected IDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 m/min) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White Dimensions 4 7/8 in. Dia. x 1 7/8 in. H, mounted in base (124 mm x48 mm) I i ANSUL AAubPulsej Detection and Control Components LIFEalarms Photoelectric Smoke Detectors For Two-Wire Bases I Features LiFEalarm® Photoelectric smoke detector with on-board I sensitivity drift compensation* Functional chamber enclosure: Louvered design enhances smoke capture by directing I . flow to chamber Entrance areas are minimally visible when ceiling I mounted Multi-function indicator LED indicates normal and alarm conditions I Magnetically operated functional test: Initiates alarm and verifies performance I . Identifies general sensitivity status using detector LED Models available in two sensitivity settings: Part No. 430559 (Part No. 430695 ULC), Standard I Sensitivity, nominal 2.8%/ft obscuration Part No. 430562, Special Application Sensitivity, nominal 3.5%/ft obscuration I Available base options: Bases for 2-wire operation Auxiliary alarm relay output I Optional remote alarm indicating LED Description I LlFEalarm photoelectric detectors provide many of the proven analog sensing features for applications where detectors are connected to conventional 2-wire initiating ' device circuits (lDCs). Each detector has an on-board micro- processor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is I present. LlFEalarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high perfor- I mance smoke capture ability. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. * LlFEalarm smoke detector operation is protected by one or more of the following U.S. Patents: 5155468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; 0383,407; D388,352; 0392,573. I I I Smoke Detector Features Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accu- mulation of dust and dirt. With analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the proba- bility of false or nuisance alarms caused by shifts in sensitiv- ity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. Application Reference Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. For further detailed installation information, refer to Detectors, Sensors, and Bases Application Manual, Part No. 431424. Sensitivity Selection. The standard sensitivity detector, Part No. 430559, is recommended for most applications. When a special application for a reduced sensitivity detector is required, Part No. 430562 should be considered. Consult Ansul for assistance in determining the proper selection. I I 1 I Product Selection Smoke Detectors Part No. Description Nominal Sensitivity Compatibility - 430559 and 430695 (ULC) LIFEalarm Photoelectric Detector 2.8%/ft (standard) Compatible with detector bases: Part Nos. 430567 and 430569 430562 3.5%/ft Compatible Bases Part No. Description Details 430567 2-Wire Base with connections for IDC and LED connections are screw terminals for 430701 (ULC) Remote Alarm LED Indicator in/out wiring, 18 to 14 AWG 430569 2-Wire Base with Auxiliary Alarm Relay Relay Ratings, Dual Form "C", For Suppressed Loads: 430702 (ULC) & connections for Remote LED Indicator Power limited, 1 A @ 28 VDC NOTE: Must be connected as the only device Non-power limited, 1/2 A @ 120 VAC on the IDC to ensure relay operation. Wiring Connections (In/Out where required): Relay contacts and IDC (-), color coded 18 AWG leads 430570 2-Wire Base with Remote LED Indicator 430703 (ULC) IDC (+) and LED wiring, screw terminals for 18 to 14 AWG 430572 Remote LED Alarm Indicator 430704 (ULC) Detector Accessories Part No. Description Details 430646 Adapter Plate Required for mounting to 4 in. square box, fits 4 in. octagonal box May be used when retrofitting existing bases Compatible with Part No. 430567 and Part No. 430569 detector bases 430572 Remote LED Indicator Mounted on single gang stainless steel plate I I I I 1 I I I Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within compensation range None LED pulses quickly, 6 times in 3 seconds, then turns ON Alarm is initiated More sensitive, out of normal compensation range Cleaning or other service is required LED pulses slowly, 4 times in 8 seconds, then turns ON Alarm is initiated Less sensitive, out of normal compensation range Does not initiate Alarm Detector is malfunctioning Service is required *Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual, Part No. 431424, for further test and maintenance information. Dimensions and Reference Information 1/4 IN. (6.4 mm) !i 6 3/8 IN. (162 mm) OPTIONAL ADAPTER PLATE, PART NO. 430646 (REQUIRED FOR 4 IN. SQUARE BOX) 4 7/8 IN. II (124 mm) BASE HEIGHT 17/8 IN. 11/16 IN. (17 mm) 1111 I II Ill (48 mm) 'Th II i-1iii7 006565 (WITH CLEAR LENS) PART NO. 430559 AND PART NO. 430562 DIMENSIONS MOUNTED ON BASE LIN ALARM 0 UNS 006587 REMOTE RED LED INDICATOR, PART NO. 430572 (NOT TO SCALE) Mounting Information ELECTRICAL BOX REQUIREMENTS: WITHOUT RELAY (BASE, PART NO. 430567); 4 IN. OCTAGONAL OR 4 IN. SQUARE, 11/2 IN. DEEP SINGLE GANG, 2 IN. DEEP WITH RELAY (BASE, PART NO. 430569): 4 IN. OCTAGONAL, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING 4 IN. SQUARE, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING SURFACE MOUNT REFERENCE 4 IN. (102 mm SQUARE BO) 4 IN. (102 mm) OCTAGONAL BOX 11/2 IN. (38 mm) FLUSH MOUNT REFERENCE, MOUNT EVEN WITH FINAL MINIMUM BOX DEPTH SURFACE, OR WITH UP TO 1/4 IN. (6.4 mm) MAXIMUM RECESS ADAPTER PLATE, PART NO. 430646, REQUIRED FOR MOUNTING TO SURFACE MOUNTED BOXES AND TO 4 IN. SQUARE FLUSH MOUNT BOXES PART NO. 430569 INCLUDES A RELAY MODULE THAT MOUNTS IN BASE ELECTRICAL BOX SMOKE DETECTOR BASES, PART NOS. 430567 AND 430569 008568 SMOKE DETECTOR, PART NOS. 430559 AND 430562 ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINEflE, WI 54143-2542 715-735-7411 Form No. F-2002159 02003 Ansul Incorporated Litho in U.S.A. Page 1 of I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ' OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1597:0105 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: TEPG - US91 Technology Or, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattemtycoint.com DESIGN: Models 430559, 430560, 430562, *T360..9001 and *T360..9002 photoelectric type smoke detectors. Models 430560 and *T360..9002 employ an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, *electricel/air velocity rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed compatible fire alarm control units. Intended for use with separately listed Models 430567, 430569, 430570, *T360..9902 *9903 and *..9904 detector bases (CSFM Listing No. 7300-1597:107). For indoor use only. XLF: 7272-0026:0219 *Rev. 05-11-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -0026:0222) CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmatterntycoint.com DESIGN: Models 4098-9682, 4098-9683, 4098-9788 and 4098-9684 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division DN-7087:BI SpectrAlert® Advance N OT I F I E R® Selectable Output Notification Appliances by Honeywell General - System Sensor® SpectrAlert® Advance selectable-output horns, strobes and horn/strobes are rich with features guaran- teed to cut installation times and maximize profits. The Spec- trAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installa- tion of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four- inch octagon, or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: 12 or 24 volts. At24volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of a rear-mounted slide switch and front viewing window. Horn tones and volume by way of a rotary switch. The SpectrAlert Advance series includes outdoor notifica- tion appliances. Outdoor strobes and horn/strobes (two- wire and four-wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between -40°F and 151°F (-40°C and 66°C) in wet or dry applications. Models available: Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- wire horn/strobe. Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Features Plug-in design. Same mounting plate for wall- and ceiling-mount units. Shorting spring on mounting plate for continuity check before installation. Captive mounting screw. Tamper-resistance capability. Field-selectable candela settings on wall and ceiling units: 15, 15/75,30,75,95, 110, 115, 135, 150, 177, 185. Automatic selection of 12 or 24 volt operation at 15 and 15/ 75 candela. Outdoor wall and ceiling products. .:!91 Indoor Ceiling Outdoor Ceiling Horn/Strobe Strobe j H ap Indoor Wall Indoor Ceiling Horn/Strobe Strobe Ei Indoor Wall Outdoor Wall Horn Strobe Outdoor products rated from -40°F and 151°F (-40°C and 66°C). Outdoor products rainproof per UL50 (NEMA 3R) and weatherproof per NEMA 4X, 1P56 Minimal intrusion into the backbox. Horn rated at 88+ dbA at 16 volts. Rotary switch for tone selection. Three horn volume settings. Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shall mount to a standard 4.0" x 4.0° x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0° (10.16 cm) octagonal backbox, or a double- gang backbox. Two-wire products shall also mount to a single- gang 2.0" x 4.0'x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- trAlert Advance products, when used with the Sync*CircuitTm Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncCircuit Module, 12- volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-recti- fied, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150,177,185. DN-7087:81 • 09/27/2010 -Page 1 of 4 STROBE The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- age range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN/STROBE COMBINATION The horn/strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys- tem. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple posi- tion switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between -40°F and 151°F (-40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weather- proof backbox with half-inch and three-fourths-inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync.Circuit MDL3R or MDL3W listed to UL 464 and shall be approved for fire protec- tive service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688° x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) back- box. The module shall also control two Style Y (class B) cir- cuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Strobe Current Draw, UL Maximum (mA RMS) Candela 8-17.5V 16-33V DC FWR DC FWR Standard Candela Range T" 1 1 7=66 71 15/75 142 148 77 81 30 NA I N/A 94 96 75 NA NA 158 153 - NA NA TT 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 T7_7 NA NA 281 251 185 NA NA 286 258 Operating Specifications Standard operating temperature: 32°F to 120°F (0°C to 49°C). K Series operating temperature: -40°F to 151°F (-40°C to 66°C). Humidity range: 10% to 93% non-condensing (indoor products). Strobe flash rate: 1 flash per second. Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Operating voltage range: 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE: F S, PC, and SC prod- ucts will operate at 12 V nominal only for 15 cd and 15/75 cd. Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm2). Ceiling-mount dimensions (Including lens): 6.8" diame- ter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). Wall-mount dimensions (Including lens): 5.6" H x 4.7" W x 2.5'D (14.2 cm H x11.9 cm W x 6.4 cm D). Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cm W x 3.3 cm D). Agency Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. UL Listed: S4011 (HR_, HW_, P2......, P4_, PC2_, PC4 models); S5512 (models SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, SRHK, SRK). ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications. FM approved MEA: 452-05-E CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); 7300-1653:0188 (P2., P4_, PC2., PC4_ modules); 7135-1653:0189 (HR, HAK, HW); 7300- 1653:0187 (SCRHK, SCRK, SRHK, SRK). Horn Current Draw, UL Maximum (mA RMS) Sound Pattern dB 8-17.5V 16-33V DC I FWR DC I FWR Temporal High 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 7 55 69 75 Coded Medium F44 51 56 69 Coded I Low 140 46 52 50 Page 2 of 4— DN-7087:B1 • 09/27/2010 Horn and Horn/Strobe Rotary Switch Setting Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn High 5 Normal horn Medium 6 Normal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low *NOTE: Serengs 7, 8, and 9 are not available on 2-wire horn/strobe. Horn and Horn/Strobe Output (dBA) Switch Position Sound Pattern dB 8-17.5V 16-33V - DC - FW R - DC - FW R Temporal High 71 7- 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non-temporal High 82 5 Non-temporal Medium 78 78 85 85 6 Non-temporal Low 75 75 81 81 7* Coded High 88 8* Coded Medium 178 178 85 85 9* Coded Low 75 175 81 81 *NO-=at ings 7, 87and 9 are not avatiabie on 2-wire hornIst-roge— Two-Wire Horn/Strobe, STANDARD Candela Range (15- 115 Cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB Level 16 8- 17.5 V 16-33 V 15175 16 jj 30 75 95 110 115 7 =7V—=7§r-== DC Input, Temporal, High ]0696DC Input, Temporal, Medium 80 ) 157 182 201 210 DC Input, Temporal, Low 66 77 93 154 179 198 207 DC Input, Non-temporal, High = 7' 11 ,— _ DC Input, Non-temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input, Non-temporal, Low 131 79 96 156 182 201 210 FWR Input, Temporal, High T FWR TIT 7 Input, Temporal, Medium 129 t14468 78 88 103 160 184 202 206 FWR Input, Temporal, Low 129 76 86 101 160 184 194 201 FWR Input, Non-temporal, H igh T Tr TT 126 T T FWR Input, Non-temporal, Medium 1134 1155 185 95 110 1166 189 208 216 FWR Input, Non-temporal, Low 1132 1154 180 90 105 1161 1184 1202 1211 I Two-Wire Horn/Strobe, HIGH Candela Range (135 - 185 Cd), UL Maximum Current Draw (mA RMS) DC Input 16-33V FWR Input 16-33V 135 150 - - - - 177 185 - 135 - 150 - 177 - 185 DC, Temporal, High 245 259 290 27 FWR, Temporal, High 2r r 28— DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low 232 251 282 292 FWR, Temporal, Low 207 221 248 256 DC, Non-temporal, High ! FWR, Non-temporal, High — DC, Non-temporal, Medium 242 259 293 299 FWR, Non-temporal, Medium 219 232 262 267 DC, Non-temporal, Low 238 254 291 295 FWR, Non-temporal, Low 214 229 1256 262 7087dim120090 DN-7087:81 • 09/27/2010 - Page 3 of 4 I -> Ordering Information Model Description Model j Description WALL HORN/STROBES CEILING HORN/STROBES P211 2-wire horn/strobe, standard cd, red. PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red. PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor. PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor. PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, standard cd, white. PC2W 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white. PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard Cd, red. PC4R 4-wire horn/strobe, standard cd, red. 134RH 4-wire horn/strobe, high cd, red. PC4RH 4-wire horn/strobe, high Cd, red. P4RK 4-wire horn/strobe, standard cd, red, outdoor. PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor. PC4RHK 4-wire horn/strobe, high Cd, red, outdoor. P4W 4-wire horn/strobe, standard cd, white. PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire horn/strobe, high cd, white. PC4WH 4-wire horn/strobe, high Cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red. SCR Strobe, standard cd, red. SRH Strobe, high Cd, red. SCRH Strobe, high cd, red. SRI( Strobe, standard cd, red, outdoor. SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high Cd, red, outdoor. SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white. SCW Strobe, standard cd, white. SWH Strobe, high Cd, white. SCWH Strobe, high cd, white. ACCESSORIES HORNS BBS-2A Backbox skirt, wall, red. HR Horn, red. BBSW-2A Backbox skirt, wall, white. HRK Horn, red, outdoor. BBSC-2A Backbox skirt, ceiling, red. HW Horn, white. BBSCW- Backbox skirt, ceiling, white. ACCESSORIES, continued SA-WBB Weatherproof backbox, wall. MP-2W-20BP 2-wire indoor mounting plates, pkg of 20. SA-WBBC Weatherproof backbox, ceiling. cont'd at right MPK-2W-20BP 2-wire outdoor mounting plates, pkg of 20. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd' refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. For strobes and horn/strobes, add suffix "F" for French or "B" for Bilingual. All outdoor models ("K" suffix) include weatherproof backbox. Sync.Circuitm Is a trademark and NOTIFIER® and SpectrAlert® are registered trademarks of Honeywell International Inc. I 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I iso 9001 This document Is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 1133MG03cm We cannot cover all specific applications or anticipate all requirements. MNINNI &MMlfACUtO All specifications are subject to change without notice. I QUALITY SYSTEMS For more Information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifler.com Page 4014- DN-7087:B1 • 09/27010 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA.WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed S\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V * operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SYSTIEnIII Audible Visible Accessories System Sensor offers a wide range of Audible Visible (AV) accessories to enable you to meet a variety of application requirements. I Features MP120K Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire SpectrAlert Advance® devices Color Lens Attachments Easily turns any device into a strobe for ECS, severe weather, sprinkler activation and more Outdoor rated from —35°F to 151°F Wall- or ceiling-mount lenses available UL 1638 listed WTP Weatherproof Plates Enables flush mounting of outdoor devices to brick, ceramic tile, concrete, and masonry brick Weatherproof per NEMA 3R For use in both indoor and outdoor applications For use with all K series (outdoor) products replacement -R models Universal mounting plate easily attaches to the weatherproof plate Agency Listings ®I MEA4 LISTED approved S4011 7300-1653:195 592-06-6 S3593 7300-1653204 7300-1653:0222 The MP120K Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. (çolorL:eiAhmeninstall easily on any indoor or outdoor SpectrAlert Advance strobe devices to provide distinctive visual signaling. WTP Series Weatherproof Plates enable installers to flush mount outdoor horns, strobes, horn strobes, speakers, and speaker strobes to a variety of wall surfaces, including brick, ceramic tile, concrete, and masonry brick, These NEMA 3R-rated plates come in red and white to suit aesthetic and functional requirements. Compatible with our outdoor devices, which can be used in indoor and outdoor environments, as required by conditions. They easily attach to the SpectrAlert Advance universal mounting plate. Trim Rings for speakers and speaker strobes allow for additional space within the backbox. Trim ring for horns, strobes, and horn strobes allow 4-wire devices to mount to a single-gang back box. SpectrAlert Advance Outdoor Back Boxes ensure a NEMA 4X watertight listing for AV devices. In locations where you have a hard surface to mount to, Surface Mount Back boxes are the best solution. If you have an exposed junction box, the Back Box Skirts offer an attractive solution to mask the junction box exposure. Retrofit Plates cover paint outlines on the wall when replacing legacy SpectrAlert Advance products. SpectrAlert Advance DECALS are for use on our non-pad printed wall- and ceiling-mount devices. Each decal comes with AGENT, EVAC, ALERT, or FIRE label options. The Sync.Circult Module synchronizes SpectrAlert Advance strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires, Patented module technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair of wires. See the Sync'Circuit Datasheet for more information. Specifications IIFAU . 120 VAC mounting plate model MP120K shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a two-wire SpectrAlert® Advance horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x21/8 -inch junction box. For outdoor applications, the mounting plate shall be installed using the proper SpectrAlert Advance outdoor weatherproof back box and outdoor listed notification appliance. MP120K may be used with any of the following products at all horn and strobe settings: P2R, P2RH, P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, SR-P, SW- P, SRH-P, SWH- P2R-P, P2W-P, P2RH-P, P2WH-P, SCR-P, SCW-P, SCRH-P, SCWH-P, PC2R-P, PC2W-P, PC2RH-P, PC2WH-P, SR-SP, SRH-SP, P2R-SP, P2RH-SP, SCW-SP, SCWH-SP, PC2W-SP, PC2WH-SP, CHR, CHW, CHSR, CHSW, Standard Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. The SpectrAlert Advance weatherproof plate for horns, strobes, and horn strobes shall mount to 4x4x11/4-inch and 2x4x11/2-inch back boxes. The weatherproof plate for speakers and speaker strobes shall mount to 4x4x21/8-inch back boxes. The weatherproof plate may be installed on brick, concrete, ceramic tile, and masonry brick and must be used with System Sensor "K" series outdoor replacement models (-R). Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F Iffft1iT Speaker Strobe 7,25" Lx 6.26" W x 3.00" D (including speaker and lens) Speaker 7.25" L x 6.26" W x 1.30" 0 (including speaker) Horn Strobe 6.90" Lx 5.90" W 2.80" D (including strobe lens) Horn . - 6.90" Lx 5.90" W x 1.60" D (including horn) Note: WTP and WTPW are compatible with 4401/4-inch and 2x4x11/2-inch back boxes. (Compatible with outdoor horns, horn strobes and strobes) WTP-SP and WTP-SPW are compatible with 4421/8-inch back boxes. (Compatible with outdoor speakers and speaker strobes) Ip.'1ThTh.RUM ,. . WTP/WTPW HRK-R WTP/WTPW SRK-R, SWK-R WTP/WTPW P2RK-R, P2RHK-R, P4RK-R, P2WK-R WTP-SP SPRK-R, SPWK-R WTP-SPW SPSRK-R, SPSWK-R Note: -R models ship without the outdoor back box. The weatherproof mounting plates are designed to be used only with -R replacement models Specifications The System Sensor SpectrAlert Advance colored lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with non-FIRE-printed System Sensor strobe devices. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from —35°F to 151°F Colored lens attachments may be used with the following System Sensor plain (non-FIRE-printed) indoor or outdoor strobe models: SR-F, SRH-P, SW-F, SWH-P, P2R-P, P2W-F, P2WH-P, P2RK-P, P2RHK-P, SCW-P, PC2R-P, PC2W-P, PC2WH-P, SPSW-P, SPSR-P, SPSWH-P, SPSRH-P, SPSWV-P, SPSRV-P, SPSCW-P, SPSCWH-P, SPSCWV-P, SPSC\ANH-P, SRK-P, SRHK-P, SWK-P, SWHK-P, P2WK-P, P2WHK-P, SPSWK-P, SPSRK-P, SW-CLR-ALERT, SCW-CLR-ALERT, SPSCW-CLRALERT. Colored Lens Installation I (installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe Candela Rating for UL 1638 Light output of color lenses is measured per UL 1638, on axis, and is OQI derated Candela Switch Setting On-Axis Candela Rating (UL1638) - All Colors 15 15 15/75* NA 30 30 75 75 95 95 110 110 115 115 135 135 150 150 177 177 185 185 * 15/75 Candela setting not to be used with color lenses Ordering Information (continued) MOM ftmm= Metal Weatherproof Ba:kb:x:s Colored Lenses MWEBW white, wall-mount, compatible with: SPWK-R, LENS-B Wall-mount blue LENS-R Wall-mount, red SPSWK-CLR-ALERT LENS-G Wall-mount, green MWBB red, wall-mount, compatible with: SPRK-R, SPRK, SPSRK-P, SPSRK, SPSRK-R LENS-A Wall-mount, amber MWBBCW white, ceiling-mount, compatible with: SPCWK, LENS-BC Ceiling-mount, blue SPSCWK,SPCWK-R, SPSCWK-R, SPSCWHK, LENS-RC Ceiling-mount, red SPSCWHK-R LENS-GC Ceiling-mount, green SA-WBBW white, wall-mount, compatible with: P2WK, LENS-AC Ceiling-mount, amber P2WHK, P2WHK-P, P2WK-P, SWK, SWK-R, SWK-P, P2WHK-R, P2WK-R, SWHK, SWHK-P, P4WK Decals SA-WBB red, wall-mount, compatible with: P2RK, DECAL-R red, used for non-pad-printed wall-mount P2RK-P, P2RK-R, SRK, SRK-P, SRK-R P2RHK, devices. (10 total decals per box for 5 devices)* P4RK, P4RHK, SRHK, HRK, P2RHKR, P2RKR, DECAL-RC red, used for non-pad-printed ceiling-mount HRK-R, P4RHK-R, P4RKR devices. (15 total decals per box for 5 devices)* SA-WBBCR red, ceiling-mount, compatible with: SCRK, DECAL-W white, used for non-pad-printed wall-mount SCRHK, PC2RK, PC2RHK devices. (10 total decals per box) for 5 devices* SA-WBBCW white, ceiling-mount, compatible with: PC2WK, DECAL-WC white, used for non-pad-printed ceiling-mount PC2WHK, PC4WK, SCWK, SCWHK devices. (15 total decals per box for 5 devices)* Surface Mount Back Box "All Decals include Labels: "AGENT, EVAC, ALERT & FIRE" SBBR red, wall-mount, compatible with: HR, CHR, SR, Retrofit Plates SR-SP, SRH, P2R, P2RSP, P2RH, P4R, P4RH, (For use with horn strobe & speaker strobe devices) CHSR, P2R-P, SR-F, SRH-P RFPW 9.5" x 7" white SBBW white, wall-mount, compatible with:HW, CHW, SW, SWH, P2W, P2WH, P4W, P4W-F, CHSW, P2W-F, RFP 9.5" x 7" red P2WH-P, SW-F, SWH-P, SW-ALERT, SWH-ALERT Mounting Plate SBBSPR red, wall-mount, compatible with: SPR, SPRV, MP120K 120 VAC Adapter Mounting Plate SPSR, SPSRH, SPSRV, SPSR-P, SPSRH-P, SPSRV-P Sync Modules SBBSPW white, wall-mount, compatible with: SPW, SPWV, MDL3W white, 12/24 volt Sync-Circuit module. SPSW, SPSWH, SPSWV, SPSW-P, SPSWH-P, SPSW-ALERT, SPSW-CLR-ALERT MDL3R red 12/24 volt Sync-Circuit module SBBCR red, ceiling-mount compatible with: SCR, SCRH, Trim Rings PC2R, PC2RH, PC4R, PC4RH, SPCR, SPCRV, TR red, wall-mount for use with speaker devices SPSCR, SPSCRH, SPSCRV, SPSCRVH, PC2R-P TRC red, ceiling-mount for use with speaker devices SBBCW white, ceiling-mount, compatible with: SCW, SCWH, PC2W, PC2W-SP, PC2WH, TRCW white, ceiling-mount for use with speaker devices PC4W, SPCW, SPCWV, SPSCW, SPSCWH, TR-HS red, wall-mount for use with horn strobes devices SPSCWV, SPSCWVH, PC2wp, PC2wH-P, TRW white, wall-mount for use with speaker devices SCW-P, SPSCW-P, SPSCWH-F, SPSCWHK-P, SFSCWV-P, SPSCWVH-P, SPSCW-CLR-ALERT, Watertight Plates SCW-CLR-ALERT WTPW white, for use with horn, strobes & horn strobe devices Back Box Skirts WTP red, for use with horn, strobes & horn strobe devices BBS-SP201W Surface-mount back-box skirt for the PF24V WTP-SPW white, for use with speaker devices (ExitPointTM Directional Sounder with Voice WTP-SP red, for use with speaker devices Messaging) SPBBS red, wall-mount, compatible with: SPA, SPSR, SFRV,SPSR-P,SPSRH,SPSRH-P 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 02014 System Sensor. Product specifications subject to change without notice. Visit systemsensOr.cmn for current product information, including the latest version of this data sheet, www.systemsensor.com AVOS4001 • 1114 Page 1 o I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-1653:0204 - CATEGORY: 7300 — FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc. 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Models LENS-B, LENS-R, LENS-G, LENS-A, LENS-BC, LENS-RC, LENS-GC, and LENS-AC retrofit colored strobe lenses for non-fire applications with all System Sensor SpectrAlert Advance models having "-P' or "K-P' suffixes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: LENS-B: blue rectangular lens LENS-R: red rectangular lens LENS-G: green rectangular lens LENS-A: amber rectangular lens LENS-BC: blue circular lens LENS-RC: red circular lens LENS-GC: green circular lens LENS-AC: amber circular lens INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as retrofit colored strobe lenses for use with listee's separately listed and compatible strobe lights for non-fire applications. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for use as fire signaling devices for the hearing impaired. 10-17-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I i ANSUL® Detection and Control Components i Lkkuq(nPu1sej Abort Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Abort Switch is used to momentarily interrupt the release circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- sion system will not release. (Note: When the control unit is programmed for IRI compliance, the abort will not be effec- tive after pre-discharge.) When the pushbutton is released, the release circuit is activated (unless the control unit has been reset to the non-alarm condition). Description The Abort Switch assembly consists of a momentary- contact pushbutton switch, normally-open contact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous ca •f Listings and Approvals The switch is UL listed (S3623) when installed in the surface- mount box (with gasket) that is provided with the surface- mount assembly. MOUNTING DIMENSIONS TYPICAL WIRING DIAGRAMS ABORT SWITCH (SERIES) EOL RESISTOR -0)-) L j CONTROL UNIT - - - ABORT CIRCUIT N.C. ABORT I TERMINALS SWITCH ABORT SWITCH (PARALLEL) EOL RESISTOR CONTROL UNIT N.O. ABORT ABORT CIRCUIT SWITCH TERMH'JALS * SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Ordering Information Shipping Weight Part No. Description lb. (kg) 76494 Abort Switch, Surface-Mount 1.0 76495 Abort Switch, Flush-Mount 1.0 76485 Extra Contact Block, N.C. 0.25 76486 Extra Contact Block, N.O. 0.25 ANSUL and AUTOPULSE are registered trademarks. (0.45) (0.45) (0.11) (0.11) .__27/81N. (73 mm) 0 ANSUL FIRE SUPPRESSION SYSTEM ABORT O 4 5/8 IN. (117 mm) PUSH AND HOLD 0 =A SURFACE-MOUNT c/p ///I FLUSH-MOUNT 3/8 IN. -. (60 mm) 'U 3-34 ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-95111 ®1995AnsuI Incorporated Litho in U.S.A. 4 11/16 IN. - (119 mm) 0 0 NORMAL LOCK-OUT (00 ANSUL FIRE SUPPRESSION SYSTEM ABORT 0 0 FLUSH-MOUNT 23/4 IN. (70 mm) SURFACE-MOUNT 4 5/8 IN. (117 mm) ANSUL AAubPulsej Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the "lock-out" mode to serve as a reminder that the release cir- cuit has been disconnected. Detection and Control Components Key Maintenance Switch TYPICAL WIRING DIAGRAM KEY-OPERATED CONTROL UNIT LOCK-OUT SWITCH RELEASE CIRCUIT 24 VDC TERMINALS ACTUATOR NC." U • I Ø() N.O. I POLARITY IS +) I I SHOWN IN ALARM 24 VDC POWE CONDON I - SOURCE 24 VDC INDICATOR LAMP * SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Description Ordering Information The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel Part No. Description switch plate with silk-screened label. Surface-mount asse blies include a double-gang weather-proof box and . 76498 Maintenance Switch, Surface-Mount The stackable, screw-terminal contact blocks are rated for 28 76499 Maintenance Switch, Flush-Mount VDC @ 1.1 amp make/break or 6 amp continuous carry. 76485 Extra Contact Block, N.C. Listings and Approvals 76486 Extra Contact Block, N.O. The switch is UL listed when installed in the surface-mount 78179 Spare Key box (with gasket) that is provided with the surface-mount 470273 Extender-Back Box assembly. Shipping Weight lb. (kg) 2.0 (0.9) 2.0 (0.9) 0.25 (0.11) 0.25 (0.11) 0.25 (0.11) 0.25 (0.11) MOUNTING DIMENSIONS ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. 3-33 ANSUL INCORPORATED, ONE STANTON STREET. MARINETrE, WI 54143-2542 715-735-7411 Form No. F-95110-1 02003Ansul Incorporated Litho in U.S.A. 64 I 551.11 I 5.0..10 4.5 4.0 _ 8 0 -I MINUTES i.I. HOURS DISCHARGE TIME @68°F (20 °C) 004604 EFFECT OF TEMPERATURE ON CAPACITY pp- 01C a 0. 0 W-19 POMPIN'R 1 C uuIIs IBUii• 122° 140° (50°) (60°) 004645 PS SERIES BATTERIES 9 120% 100% Q 80% 60% 40% 20% 0% -4° 14° 32° 50° 68° 86° 104° (-20°)(-10°) (0°) (10°) (20°) (30°) (40°) TEMPERATURE °F (C°) SEALED RECHARGEABLE BATTERY LENGTH I i ANSUL Detection and Control Components i LAkuq(KDPu1sej PS Series Batteries Features Provide secondary power for control units Gelled electrolyte Sealed and maintenance free Overcharge protected Extended shelf life Easy handling with leak-proof construction Ruggedly constructed, high-impact ABS plastic case Long service life Compact design Applications PS series batteries provide secondary power for the AUTOPULSE® control systems. Use these batteries to pro- vide backup power for control units. Select batteries based on current requirements for your system and the capacity of its charger. These batteries can be used over a temperature range of-76 OF to +140 OF (-60 °C to +60 °C). Description The sealed construction of the battery allows trouble-free, ' safe operation in any position. There is no need to add elec- trolyte, as gases generated during overcharge are recom- bined in a unique "Oxygen Cycle? The battery is sealed, leak-proof, and maintenance free. The case is made of ABS, I a high-impact plastic resin (acrylonitrile butadiene styrene copolymer) with high resistance to chemicals and flammability. Shipping assemblies consist of two (2)12 VDC batteries pro- viding 24 VDC to the control system when connected in series. Technical Information The capacity of a battery is the total amount of electrical energy available from a fully charged cell. Its value depends on the discharge current, the temperature during discharge, the final cutoff voltage and the general history of the battery. Capacity expressed in ampere-hours (AH), is the product of the current discharged and the length of discharge time. The ' rated capacity (C, where C = rated Capacity of the battery in AH) of the PS series batteries is measured by its perfor- mance over 20 hours of constant current discharge at a tem- perature of 68 OF (20 "C) to a cutoff voltage of 1.72 volts, per cell (10.32 V on a 12 V battery). For example: Model PS-1250, with a rated capacity of 5.0 AH, will deliver 250 milli-amps (1/20 of 4 AH, or 0.05C) for 20 hours before the voltage drops to 10.32 V (1.72 x 6 cells). 1 3-1-01 3-46 I Technical Information (Continued) I Rated 20 Hour Height over Capacity Discharge Length Width Height Terminal Weight @ 20 Hour Rate in. in. in. in. lb. I Model Rate (AH) (mA rate) (mm) (mm) (mm) (mm) (kg) PS1250* 5.0 250 3.54 2.76 3.98 4.13 4.1 (90) (70) (101) (105) (1.9) I PS-1270 7.0 325 5.94 2.56 3.70 3.86 5.7 (151) (65) (94) (98) (2.6) PS-12120 12 600 5.94 3.86 3.70 3.86 8.8 I (151) (98) (94) (98) (4.0) PS-12180 18 875 7.13 2.99 6.57 6.57 12.8 (181) (76) (167) (167) (5.8) I PS-12250 25 1300 6.89 6.54 4.92 4.92 18.7 (175) (166) (125) (125) (8.5) PS-12500 50 3000 10.25 6.60 8.20 9.45 39.7 (260) (168) (208) (240) (18.0) I Note: Individual batteries have a nominal voltage of 12 volts. ' Ordering Information Shipping Weight Part No. Model No. Description lb. (kg) ' 68709* PS-1250 PS Battery Pack, 8 (3.6) 5.0AH, 24 VDC 417692 PS-1270 PS Battery Pack, 12 (5.4) I 7.0AH,24VDC 417693 PS-12120 PS Battery Pack, 18 (8.2) 12AH, 24VDC 417694 PS-12180 PS Battery Pack, 26 (11.8) 18AH,24VDC I 417695 PS-12250 PS Battery Pack, 40 (18.1) 25AH, 24VDC 417997 PS-12500 PS Battery Pack, 84 (38.1) 50 AH, 24 VDC * Supplied with wire harness; battery for use with AUTOPULSE FOUR only. ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. I I I I U ANSUL INCORPORATED, ONE STANTON STREET MARINETIE, WI 54143-2542 715-735-7411 Form No, F-95122-3 02003 Ansul Incorporated Litho In U.S.A. I I INERGEN (IG-541) Clean Agent Fire Suppression System I I LCULATIONS ANSUL INERGEN DESIGNER Version 2.1.2 I U File: Data file name: C:\Bruce Deushane\Quotes - JAM\Projects\Genoptix\Calcs\Genoptix - Server Rm 1104.inr Job: I4BD-188 I Customer: Genoptix Medical Laboratory Address: 2110 Rutherford Rd. Server Room 1104 I Carlsbad CA 92008 REMARKS: Installation of new Inergen System Protecting Server Rm 1104 Hazard Area Information Area: Server Rm 1104 I Design concentration 38.5% at 65° Fahrenheit Estimated maximum concentration 46.9% at 7mx1num hazard temperature 75° Fahrenheit Net volume of enclosure 1400.0 cubic feet I Minimum INERGEN required 687.4 cubic feet Approximate INERGEN supplied 878. cubic feet Flooding factor .491 cubic feet of INERGEN per cubic feet of enclosure volume I Maximum allowable wall strength 5.0 lbs./sq.ft. Area consists of one volume Volume 1: Length 14ftWidth 10 ft Height 10 ft I I nozzles. Nozzle identifiers: 301 Agent Storage Conditions Number of cylinders: 2 each containing 439 cubic feet of INERGEN. Total agent 878 cubic feet Engineering units (ft, Cu ft, psia) are specified I Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Calculation based on fixed nozzle and pipe sizes I Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union! Noz Eql Start End Pipe Size (ft) (ft) Tee Tee Cplg Dia (ft) 1 2 1/2 - 40 T 0.01 0.00 0 0 0 0 38.00 I 2 3 3/4 - 80 T 1.00 0.00 1 0 0 0 2 cyl 0.00 3 4 3/4 - 801 0.50 0.00 0 0 1 0 2 cyl 0.00 4 5 3/4 - 801 2.00 2.00 1 0 1 0 2 cyl 0.00 5 6 3/4 - 801 0.00 0.00 0 0 0 0 Orifice 6 7 3/4-401 2.50 2.50 0 0 0 0 0.00 3/4-401 12.00 0.00 1 0 0 0 0.00 I 8 8 301 3/4-401 1.50 -1.50 1 0 0 0 0.386 0.00 1 1 (End of Data Input File Printout) I ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF. ULC listed CEx1151 I Version 2.1.2 File: Data file name: C:\Bruce Deushane\Quotes - JAM\Projects\Genoptix\Calcs\Genoptix - Server Rm 1104.inr I Job Number I4BD-188 for Genoptix Medical Laboratory Address: 2110 Rutherford Rd. Server Room 1104 Carlsbad CA 92008 REMARKS: Installation of new Inergen System Protecting Server Rm 1104 ' Agent Storage Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. I 439 cubic feet of INERGEN stored in each of 2 cylinders. Total agent in storage is 878 cubic feet. Time to discharge 790 cubic feet (90% of INERGEN) is 75.3 seconds I Maximum pressure downstream of manifold orifice is 1232 psia 1" anlanêrd%4n ___Iu IL. I I 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. IServer Rm 1104 1400.0 47 878.0 46.9% at 75°F 46.3% at 65°F 38.5% at 65°F Sea level equivalent oxygen: 11.1% at 75°F 1 Concentrations are based on altitude of 52 ft mean sea level. Free Vent Calculation 1 Peak Maximum Wall Minimum Free Area Rate Strength Vent Area IServer Rm 1104 1676.9 cfm 5.0 Ibs./sq.ft. 64 sq. in. Pressure DroD Results I Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 401 0.0 38.0 0.0 MFLD 1033 1006 451.7 2 3 3/4 80T 1.0 2.9 0.0 MFLD 1006 1001 903.5 3 4 3/4 801 0.5 1.7 0.0 MFLD 1001 999 903.5 4 5 3/4 801 2.0 5.1 2.0 MFLD 999 993 903.5 5 6 ORIFICE .266 INCHES DRILL NO. H 993 422 903.5 - 6 7 3/4 40T 2.5 2.5 2.5 422 574 903.5 7 8 3/4 401 12.0 14.1 0.0 574 557 903.5 1 1 (Continued) I ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF. ULC listed CEx1151 I Version 2.1.2 File: Data file name: C:\Bruce Deushane\Quotes JAM\Projects\Genoptix\Calcs\Genoptix - Server Rm 1104.inr I Job Number: I4BD-188 Pressure Drop Results (Continued) Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 8 301 3/4 401 1.5 3.6 -1.5 557 553 903.5 I Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions/ EqI Start End Pipe Size (ft) 90's Tee Tee Cplgs (ft) 1 2 1/2 40 T 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 3/4 80T 1.0 1 0 0 0 I 3/4 80T 0.5 0 0 1 0 4 5 3/4 801 2.0 1 0 1 0 5 6 3/4 801 0 0 0 0 Man. Orifice 01 Nozzle Performance Summary Lozzle Nominal Drill Drill Quantity (cu It) Area Number Pipe Size Number Diameter Discharged Name I 301 3/4 40 T W 0.386 878.0 Server Rm 1104 Lssaaes/Errors I ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 Calculation based on fixed nozzle and pipe sizes. Calculation done on 6/27/2014 at 10:38:57 AM Concentrations are based on an altitude of 52 ft above mean sea level. Altitude correction factor is 1.00 2 (Continued) I ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved W.I.) 2Y0A9.AF. ULC listed CEx115i Version 2.1.2 File: Data file name: C:\Bruce Deushane\Quotes - JAM\Projects\Genoptix\Calcs\Genoptix - Server Rm II04.inr I Job Number: I4BD-I88 es saes/Errors (Continued) I pe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum pe pressure for Grade A-53B, A-I 06B Seamless. To determine if other grades are acceptable, rify that the maximum pipe pressures for other grades are equal to or greater than the maximum Iticipated downstream pressure. Calculation by JAM Fire Protection Bruce Deushane I 1930 S. Myrtle Ave. Monrovia CA 91016 USA Telephone: 626-256-4400 I Fax: 626-256-4401 3 End of Printout