HomeMy WebLinkAbout2110 RUTHERFORD RD; ; FA090004; Permit4/10/25, 8:39 AM FA090004 Permit Data City of Carlsbad Fire Alarm Permit 2110 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2120702200 Lot #: 0 Permit No: FA090004 Status: VOID Applied 1/8/2009 Approved: 1/8/2009 Reference No.: Issued: 1/8/2009 PC #: Inspector: Project Title: GENOPTIX MONITORING SYSTEM PLAN CHECK & INSPECTIONS Applicant: Owner: JMG SECURITY BLACKMORE AIRPORT CENTRE 17150 NEWHOPE C/O ALLEN J BLACKMORE SUITE 109 P0 BOX 424 RANCHO SANTA FE CA 800-900-4564 EXT.316 Fees ($) Add'I Fees ($) Total ($) I Balance ($) L 125 L ü 125 j 125 about:blank 1/1 Mar 26 09 02:28p p.2 FIRE ALARM SYSTEM RECORD OF COMPLETION Nam ofprotected property: Genoptix Medical Laboratory - Genoptix Lab Expansion Aadreast 2110 Rutherford Road, Carlsbad, Ca. 92008 Representative of protected property (name/phone): Authority kavingjnrisdiction: Carlsbad Safety Center Address/telephone nurnber. 2560 Orion Way, Carlsbad, Ca. 92010, Phone (760) 931-2141 Org w.eeor r4rulphone Reprser2etve name/phone Installer 3MG Security Systems, Inc Ph, 714-545-8882 Mike Tremblay Supplier 3MG Security Systems, Inc Ph.714-545-8882 Mike Tremblav Service organization 3MG Security Systems, Inc Ph.714-545-8882 Mike Tremblay Location ofrecord(as.built)drawings: 2110 Ru:herfort Road, Carlsbad, Ca. 92008 Location ofoperation and maintenance manuals: Same a*ove Location oftestreports: 2113 Rutherford Road, Cerltbad, Ca. 92008 A contract for test and inspection in accordance with A standard(s) Contract No(s): Et date: Expiration date: System Software Operating system (executive) software revision level(s): Site..epecific software revision date: Revision completed by. name) (firm) 1.Type(s) of System or Service NFPA 72, Chapter 6 — Local If alarm is transmitted to location(s) off premises list where received: _____NFPA 72, Chapter -Remote Station Telephone numbers ofthe organization receiving alarm: Alarm: Supervimrv: Trouble: If alarms ate retransmitted to public tire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: _____NFPA 72, Chapter S —Proprietary Telephone numbers of the organization receiving alarm: Alarm:_____ Sapervisor#: Trot.ble: If alarms are retransmItted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: X Nb'PA 72, Chapter 8—Central Station Prime contractor: DBA National Monitoring Center N4C). Centralstationlocation: 26800 Laguna Hills Drive, Suite 250. Aliso Viejo, CA. 92656 V.PA 72.1 of 41 Mar 26 09 02:28p p.3 Means oftransmisaion of signals from the pintmted premises to the central station: ______McCulloh ______Multiplex —One-way radio X Digital alarm communicator —Two-way radio ______Others Means oftransmission of alarms to the public fire service communications center: System location: NFPA72, Chapter 9—Auxiliary Indicate type of connection: ______ Local energy -Shunt ______Parallel telephone Location of telephone number for receipt of signals:______________________________________ 2. Record 01 System Installation (Pill out after installation is complete and wiring is checked for opens, short ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NPPA standards as shown below, was inspected by on , includes the devices shown in S and 8, and has been in service since ...2i_NPPA 72, Chapters 1 2 3 ®® 6 () 8 9 11. (circle all that apply) NF.PA 70, National Electrical Cie,Article 760 Manufacturer's instructions Other (speci4,): Signed: Date: Organiration: . Record 01 System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached - All operational features and functions of this system were tested by date and found In be operating properly in accordance with the requirements o ...L...NFPA 72, Chapters 1 2 3 () ® C 0 8 9 (Ij) ii (circle all that apply) ..JL NFPA 70, National Electrical Code, Article 760 jLMarnifactuxex's instructions - Other (specify): Signed:............... Date: Organization: 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NPPA 72, Table 6.6.1): Quantity: 1 Style: _4 Class: B (1':FPA 72.2014) Mar 26 09 02:28p p.4 S. Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits (see NIPA 72, Table 6.5): Quantity: 17 Style:B Class: MANUAL (a) Manual stations Noncoded________ Transmitters_ (b) Combination manual fire alarm and guard's tour coded stations B Coded______ Addressable 11 AUTOMATIC Coverage: Complete Paatial Selective. No nreq aired Smoke detectors ' Ion Photo Addressable X Duct detectors _5 Ion Photo X Addressable_______ Heat detectors _2 F'l' ER FT,RR_______ BC______ Addressable______ Sprinkler waterfiow indicators: Tranmftters 1 Noncoded X Coded _______ Addressable_______ The alarm verification feature is disabled ______ orenabled______ ,chauged from ______ seconds to______ seconds. (0 Other (list): 6. Supervisory Signal-initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a)—Coded stations (b)_Noncoded stations (c) Compulsory guard's tour system comprised of_________ transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and ma), Guard's Tout SPRINKLER SYSTEM Check if provided (a)2Valve supervisory switches __Building temperature points Site water temperature points (d)___ Site water supply level points Electric fire pump: (e) ._Fire pump power (1) .__.Fire pump running (g—Phase reversal Engine-driven fire pump: (h)_ Selector in ado position (1) _...Engine or control panel trouble (j) __Fire pump running ENGINE-DRiVEN GENERATOR: (a)_Selecbr in auto position (b)_......Control panel trouble (c) _Transfer switches (d)—Engine running Other supervisory function(s) specify): (NFPA 72,3 of 4) Mar 26 09 02:28p P.5 7. Annunciator(s) Nunber. 1 Type: LCD Location: ByLobby & Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency VoiceiAlarm Service Quantity of voice/alarm channels: Single: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in systems: Multiple: Quantity and the class of notification appliance circuits connected to system (see NFPA 72 Table 67): Quantity:15 Style: Class: B Types and quantities of notification appliances installed: Bells ____________________ With Visible Speakers With Visible__________________ Horns _55 With Visible Yes Chimes With Visible Other: With Visible Visible appliances without audible: 35 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: 24VDC Current rating: Overcurrent protection: Type: Current rating- Location: NDFRoom Secondary (standby): Storage battery: 17.2Ah Amp-hour rating. 17.2Ah Calculated capacity to drive system, in hours: 24hrs Engine-driven generator dedicated to fire alarm system:_____________________________________ Location of fuel storage: Emergency system used as backup to primary power supply: Bacrupbatteries Emergency system described in NFPA 70, Article 700:- 10. Comments Frequency of routine tests and inspections, ifother than in accordance with the referenced NFPA standard(s) System deviations (rum the referenced NFPA standard(s) are:_______________________________________ (si ned risailation contractor/supplier (title) (date) P?-&r,cr 1LLA (signed) foricr alarm seriice company (ltIt (dale) (signed) br cenlial station . (title) (date) Upon completion ofthe system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (519n9d) representative of the authority having juisdictio (liVe) (date) (NF72.4 of 4)