Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6913 TOURMALINE PL | 6915 TOURMALINE PL | 6917 TOURMALINE PL | 6919 TOURMALINE PL; ; FA110065; Permit
4/10/25, 3:18 PM FA110065 Permit Data City of Carlsbad Fire Alarm Permit 6913 TOURMALINE Job Address: PL Permit Type: FALARM Parcel No: 2131125704 Lot #: 0 Reference No.: Permit No: FA110065 Status: ISSUED Applied 8/31/2011 Approved: 9/1/2011 Issued: 9/1/2011 PC #: Inspector: ic Project Title: K&B AVELLINO LA COSTA BLDG WNEW MONITORING SYSTEM FOR MFD (4-UNIT CONDO) RESIDENTIAL, CB10101115, 101112, 10111 , 101118. Applicant: KPS ALARMS INC SUITE B 760 S. ROCHESTER AV ONTARIO, CA 909-260-0900 Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 275 0 j 275 0 about:blank 1/1 Project Building #15 Avellino 6913,6915,6917, 6919 Tourmaline Place Carsibad CA Alarm system contractor Z/ ~ -~A! ~; ~-" I ' ' \'*'S 010 LK 760 S. Rochester Avenue, Suite 1 Ontario, Ca 91761 Office 909 292-0215 Fax 909-980-4477 St Lic. C-10 No803708 App 'C'J D AS SUBMITTED CAR AD FiRE EPAR MENT I I I I I I MS-5UD-3(E)JIV1S-1 OUD-7(E) Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MS-5UD-3E and the MS-10UD-7E offer the same features as the MS-5UD-3 and MS-10UD-7 but allow connection to 220/240 VAC. NOTE: Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and the 220/240 VAC ver- sions of these panels. Features DF-5241 6:A A3-20 Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-1 OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-i UUD-7. Optional Dress Panel DP-51050. Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Optional 8 zone Relay Module ANN-RLY. Optional Remote Annunciator ANN-80. Optional Remote Printer Gateway ANN-S/PG. Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings ANN-Bus for connection to remote annunciators. I Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter) I . Style B (Class B) IDC (Initiating Device Circuit) - MS-5UD-3 - five IDCs. - MS-10UD-7 - ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-10UD-7 - four NACs. I . Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, I Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - SilEriceable or Nonsilenceable. DF-52416:A •06118107 - Page 1 of 4 Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) Left Side Right Side Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power - TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 220 VAC, 50 HZ, 0.54 A MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.90 A MS-10UD-7E (FLPS-7 Power Supply): 220 VAC, 50 HZ, 2.20 A Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.1 Minimum Battery Size: 7 AH Initiating Device Circuits - TB4 (and TB 6 on MS-10UD-7 only): Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7) Alarm Zones 6 - lOon TB6 (MS-10UD-7 only) Supervised and power-limited circuitry Operation: All zones Style B (Class B) - '-' Depth = 5.207" (13.23 cm) Top Door = 16.821" (42.73 cm) Backbox = 16.65" (42.29 cm) Depth 5 257" = i335' I Page 2 of 4— DF-52416:A 06118107 Normal Operating Voltage: Nominal 20 VDC Alarm Current: 15 mA minimum Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL-listed) Standby Current: 2 mA Refer to Fire-Lite Device Compatibility Document for listed compatible devices Notification Appliance Circuits - T135 (and TB 7 on MS- lOUD-i only): Four NACs Operation: Style V (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3(E), 2.5 A maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) - Max. Wiring Voltage Drop: 2 VDC Refer to Fire-Lite Device Compatibility Document for compati- ble listed devices Form C Relays - T138: Relay I (factory default programmed as Alarm Relay). Relay 2 (factory default programmed as fail-safe Trouble Relay). Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - T132: Remote power supply synchro- nization output, only required for the MS-SUD-3(E). 24 VDC nominal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Ordering Information MS-51LID-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). MS-5UD-3E: Same as above with 240 VAC FLPS-3 power supply. MS-lOUD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-10UD-7E: Same as above with 240 VAC FLPS-7. OPTIONAL MODULES CAC-5X: Optional Style Z (Class A) Converter Module. Con- verts Style B (Class B) Notification Appliance Circuits to Style D (Class A) and Style V (Class B). Connects to J2 on the MS- 5UD-3(E) and MS-10UD-7(E) main circuit board and to J7 on NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. ANN-LED: Mounts in the DP-51050 dress panel and provides three LEDs for each zone: Alarm, Trouble, and Supervisory. ANN-RLV: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-5513attery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. DF-52416:A - 06/18/07 - Page 3014 SYSTEM SPECIFICATIONS System Capacity Annunciators . Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.OA MS-lOUD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.9 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50/60 HZ, 0.54 A MS-10IJD-7E (FLPS-i Power Supply): 240 VAC, 50/ 60 HZ, 2.2 A Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00" (50.80 cm.) high - 22.5" (57.15 cm.) wide —8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:214 NFPA Standards The MS-5UD-3(E)/MS-1OUD-7(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). FireLite® Alarms and System Sensor® are registered trademarks of Hon- eywell International Inc. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO goot This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. , . - We cannot cover all specific applications or anticipate all requirements. QUALITY SYSTE Made in the US. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4014— OF-52416:A -06/18/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) I LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 I Email: Brian.ReynoIds2Honeywell.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-51JD-7C, MS-5UD-7E, MS-i OUD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10-UD-7E Fire alarm control units. The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both I product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator ' transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. Refer to listee's I data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module I FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module I ANN-RLY; Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and I indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not I exceed 30 seconds. 04-23-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division (a Fire-LIMALarms www.firelite.com GENERAL The Fire-Lite BG-12 Series is a cost-effective, feature- packed, non-coded series of manual fire alarm pull sta- tions. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series fea- tures a variety of models including single- and dual-action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACP5), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down posi- tion to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (lDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). Terminal-numbers are molded into the backplate, elimi- nating the need for labels. June 30, 2000 DF-52004 F-050 BG-12 Series Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices c®uS L ISTED <>M APPROVED Switch contacts are normally open. Can be surface (with SB-10) or semi-flush mounted. Semi-flush mount to a standard single-gang, double- gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the popular BO-lo Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. California State Fire Marshal 7150-0075:184 (except BG-12L06) S711 document is not intended to be used for installation purposes. We try to keep ou or anticipate all requirements. All specifications are subject to change without UU I For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Njorthford, 1 ;b dl I =1 73 ?cticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ENGINEERING & MANUFACTHRIN (888) 388-3299. Made in the U.S.A. DF-52004 - Page 1 of 2 CONSTRUCTION PRODUCT LINE INFORMATION Cover, backplate and operation handle are all molded Model of durable polycarbonate material. BG-12s Cover features white lettering and trim. Red color matches System Sensor's popular BG- 12 SpectrAlertTM horn/strobe series. OPERATION BG-12L Description Single-action pull station with pigtail connec- tions, hex lock. Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking per- sons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word 'ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bot- tom as a visible flag. Resetting the station is simple: in- sert the key or hex (model dependent), twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: 52004tb11.eps BG-12 SB-b • Height. 5.500 inches 5.500 inches (13.97 cm) (13.97 cm) Width: 4.121 inches 4.125 inches (110.4673 cm) (10.4775 cm) Depth. 1.390 inches 1.375 inches (3.5306 cm) (3.4925 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10; or semi- flush mounting on a standard single-gang, double-gang, or 4(10.16cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO" on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4" high. Page 2 of 2 - DF-52004 BG-12LSP Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-12LOB Same as BG-12L with "outdoor use" listing. Includes WBB outdoor backbox, and sealing gasket. (FM Pending) 1.390" (35.306) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2©Honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-Psi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12L0B are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division - Models Available Two-Wire Models 2W-B 2WT-13 2-wire standard 2-wire standard with thermal Four-Wire Models 4W-B 4-wire standard 4WT-B 4-wire standard with thermal Accessories 2W-MOD2 2-wire loop test/ maintenance module SENS-ROR Sensitivity reader RT Removal/ replacement tool A77-AB2 Retrofit adapter bracket I 1 Product Overview Plug-in detector line - mounting base System Sensor's i3" series smoke detectors represent a significant advancement in included conventional detection. The P family is founded on three principles: Installation ease, Intelligence, and Instant inspection. Large wire entry port In-line terminals with SEMS screws Installation ease. The 13 line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large Mounts to octagonal and single-gang wire entry port and in-line terminals provide ample room for neatly routing the backboxes, 4-square backboxes, or wiring inside the base. The base accommodates a variety of back box mount- direct to ceiling ing methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug-in to the base with a simple Stop-Drop 'N Lock Stop-Drop 'N Lock' attachment to base action. Removable detector cover and chamber Intelligence. 13 detectors offer a number of intelligent features to simplify for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are standard with the 13 line, to minimize nuisance alarms. When connected to the Built-in remote maintenance signaling 2W-1\4OD2 loop test/maintenance module, or a panel equipped with the 13 protocol, 2-wire 13 detectors are capable of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleaning. This signal is indicated via an LED algorithms located at the module and the panel. To read the sensitivity of 13 detectors, the SENS-RDR is a wireless device that displays the sensitivity in terms of percent Simplified sensitivity measurement per foot obscuration. Wide angle, dual color LED indication Instant inspection. The 13 series provides wide angle red and green LED indica- tors for instant inspection of the detector condition,, indicating: normal standby, Loop testing via EZ Walk feature out-of-sensitivity, alarm, or freeze trouble conditions. When connected to the Built-in-test-switch the EZ Walk loop test feature is available on 2-wire 13 detectors. This feature ® MEA MSFM verifies the initiating loop wiring by providing LED status indication at each detector. LISTED approved approved S911 3011446 7272-1209:210 290-01-E 2093 Architect/ Engineer Specifications Smoke detector shall be a System Sensor i3 Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (model 2W-B, 4W-B) or a combination photoelectric! thermal (model 2WT-B, 4WT-B) with ther- mal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal single gang, and 4-inch square back boxes Electrical S Operating Voltage Nominal: 12/24V non-polarized Mm.: 8.5V Max.: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring con- nections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug- in type. The detector shall have a nomi- nal sensitivity of 2.5% per foot nominal as measured in the UL smoke box. The detector shall he capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby. Out of sensitivity, alarm, and freeze trouble (model 2\VT-B, 4WT-B) conditions. When used in conjunc tion with the 2W-M0D2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Standby Current Peak Standby Current 2-wire: 50 pA maximum average 2-wire: 100 pA 4-wire: 50 pA maximum average 4-wire: n/a Maximum Alarm Current Alarm Contact Ratings 2-wire: 130 mA limited by control panel 2-wire: n/a 4-wire: 20 mA @12V, 23mA @ 24V 4-wire: 0.5 A @ 30V AC/DC LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every S seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Physical Specifications Operating Temperature Range Sensitivity Mounting 2W-B and 4W-B: 32°F-120°F (0°C-491C) 2.5%/ft. nominal 3t-inch octagonal back box 2WT-B and 4WT-B: 32°F-100°F (0°C-37.81C) 4-inch octagonal back box Input Terminals single gang back box Operating Humidity Range 14-22 AWG 4-inch square back box with a plaster ring o to 95% RH non-condensing Dimensions (including base) Direct mount to ceiling Thermal Sensor 5.3 inches (127 mm) diameter 135°F (57.2°C) fixed 2.0 inches (51 mm) height Freeze Trouble Weight 2WT-B and 4WT-B only: 41°F (5°C) 6.3 oz. (178 grams) Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire j 130 mA max. limited by control panel 2WT-B Yes 2-wire j 130 mA max. limited by control panel 4W-B No 4-wire 20 mA 8' 12V, 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA 8' 24V Model Description 2W-M002 2-wire loop test / maintenance module SENS-RDR Sensitivity reader RT Removal / replacement tool A77-A82 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter ---- - Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor - Far East System Sensor - India 825Ohie-Avexiue RIw-9458T-2-O-7-6-7 P62.988-3-2.O449 P4594--9003 Rtxr-944-246-37-47-7-O-x-.2-700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0318-005ef04•#1280 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC I LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 I Email: trish.linhart@systemsensor.com DESIGN: Models 2W-B, 2WT-13, 4W-13 and 4VVT-B photoelectric type smoke detectors. Models 2W-B and 2WTB are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2\NT-B and I 4\NT-B employ a thermistor type heat sensor (135F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. I RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. I APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 1 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not S, an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued.- Authorized By I July 01, 2011 FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing Expires June 30, 2012 PRODUCT DATA SHEET - - — ----- - -- -- S - — 1530 Shields Drive Waukegan, IL 60085 Toll-Free (800) 323-9355 Fax: (847)689-1192 PART NUMBER: 51013 DESCRIPTION: 14 AWG STRANDED TYPE THHNITHWN FIXTURE WIRE CONSTRUCTION: This cable consists of one bare copper conductor with integral insulation and jacket. APPROVALS: UL Standard 62 and Subject 758 APPLICATION: Fixture Wire, Appliance Wring Material, Canada T90-Nylon, Canada TWN75 Construction Parameters: Conductor Stranding Insulation Material PVC Insulation Thickness Nylon Insulation Thickness Insulated Conductor Diameter Number of Conductors Approximate Cable Weight Electrical & Environmental Properties: 14 AWG Bare Copper 19/.0147" PVC/Nylon 0.016" Nom. 0 005" Nom. 0.112" Nom. 16.4 Lbs/1M' Nom. Temperature Rating -20°C to 105°C Operating Voltage 600V Max Impedance 41.08 Ohms/1M' DC Resistance per Conductor @20°C 2.52 OhmsllM' Insulation Color Varies Legend (Surface Ink Print) BARON 14 AWG (UL) E101736 THHN OR TI-IWN 600V GASOLINE & OIL RES I OR Am STYLE 1316 & 1408— C(UL) T90 NYLON OR TWN75 FT1 On special orders, the customer will accept all mil lengths and 'r/- 10 percent of total order requested. The information presented here is, to the best of our knowledge, true and accurate, Since conditions of use are beyond Coleman Cable's control, all product data presented is for informational purposes Only and does not create a binding obligation or liability on Coleman Cable or confer any tights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name Customer Approval Specification Issue Date: October 24, 2005 1-800-323-9355 (Phone) Designed By: PEP 1-847-689-1192 (Fax) 51013 0 2005 Coleman Cable, Inc. I PRODUCT DATA SHEET - — - -- — -- -- Ir — - — 1530 Shields Drive -- - - — Waukegan, IL 60085 Toll-Free (800) 323-9355 I Fax: (847)689-1192 PART NUMBER: 97814 I DESCRIPTION: 14/2 SOLID FLAT FPLR ZIP CABLE CONSTRUCTION: This cable consists of two bare copper conductors laid flat with an integral insulation and jacket. APPROVALS: UL Standard 1424, NEC Articles 760. I APPLICATION: Power Limited Fire Alarm Circuit Cable Intended for Riser Applications Construction Parameters: Cable Cross-Section Conductor 14 AWG Bare Copper o I Stranding Solid Insulation Material PVC Insulation Thickness 0.030" Nom. c Insulated Cable Dimensions 0.124" x 0.253" Nom. I Number of Conductors 2 Approximate Cable Weight 37.0 Lbs/1M' Nom. Flame Rating UL 1666 Riser Flame Test Electrical Properties: I Temperature Rating -20°C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz #REFl I Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @ 20°C 2.54 Ohms/1 M Nom. I Insulation/Jacket Colors White, Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 * 14 AWG 2/C (UL) TYPE FPLR SUN RES On special orders, the customer will accept all factory lengths and +1- 10 percent of total order requested. The jacket is sequentially footmarlced. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cables standard warranty, Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual properly of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name______________________ Customer Approval Specification Issue Date: December 27, 2005 I I I I 1-800-323-9355 (Phone) 1-847-689-1192 (Fax) I 97814 Designed By: PEP Itt 2005 Coleman Cable, Inc. I PRODUCT DATA SHEET AV= ff i 1530 Shields Drive Waukegan, IL 60085 Toll-Free (800) 323-9355 Fax: (847) 689-1192 PART NUMBER: 98181 DESCRIPTION: 18/2 SOLID FPL FT1 MID-CAPACITANCE CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in General Purpose Applications for Addressable Fire Alarm Systems Construction Parameters: Cable Cross-Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Polypropylene Insulation Thickness 0.006 Nom. Insulated Conductor Diameter 0.052 Nom. Number of Conductors 2 Lay Length 4.00 Nom. Separator/Wrap None Jacket Material PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter 0.132" Nom. Approximate Cable Weight 16.0 Lbs/1M' Njom. Flame Rating UL 1581 Vertical Tray Flame Test Electrical Properties: Temperature Rating -20°C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 19 pF/ft Nom. Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @ 20°C 6.32 Ohms/1 M' Nom. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 * 18 AWG 2/C (UL) TYPE FPL SUN RES - C(UL) TYPE CM FT1 —ADDRESSABLE FIRE CABLE On special orders, the customer will accept all factory lengths and +1- 10 percent of total order requested. The jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disdosed to any party without written consent of Coleman Cable. Customer Customer Approval Specification Issue Date: December 27, 2005 1-800-323-9255 (Phone) Designed By: PEP 1-847-689-1192 (Fax) 98181 02005 Coleman Cable, Inc. PRODUCT DATA SHEET -- - - -- -- 1530 Shields Drive — _ — Waukegan, IL 60085 Toll-Free (800) 323-9355 Fax: (847) 689-1192 PART NUMBER: 81804 DESCRIPTION: 18/4 SOLID FPLP FT6 CABLE CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Construction Parameters: Cable Cross-Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.006" Nom. Insulated Conductor Diameter #N/A Number of Conductors 4 Lay Length Parallel Jacket Material Low Smoke PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter #N/A Approximate Cable Weight #N/A Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical Properties: Temperature Rating -20°C to 750C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz #NJIA Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @ 20°C #N/A Insulation Colors Black Red Green Yellow Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81804 18 AWG 4/C C(ETL) US (ETL CODE) TYPE FPLP 75C -- TYPE CMPFT6 On special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The jacket is sequentially footmariced. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable, Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name Date Signed Customer Approval Specification Issue Date: November 21, 2005 1-800-323-9355 (Phone) Designed By: PEP 1-847-689-1192 (Fax) 81804 © 2005 Coleman Cable, Inc. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1236:0102 Page 1 of 1 CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: Coleman Cable1530 Shields Dr, Waukegan, IL 60085 Contact: Howard Caccia (847) 672-2000 Fax (847) 689-9116 Email: hgccoIeman-cable.com DESIGN: Type FPL, FPLR and FPLP fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Art. 760 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. NOTE: Formerly 7161-0756:100 *Rev. 06-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct "a operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division VSR-F 0 POTTER VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD -- U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8". LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted Service Pressure: Upto450 PSI Minimum Flow Rate forAlarm: 10 GPM Maximum Surge: 18 FPS Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 1 25/250 VAC 2.0Ampsat30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoororoutdoor use with factory installed gasket and die-cast housing. NEMA4/IP54Rated Enclosure- usewith appropriate conduit fitting Temperature Range: 40°F/120"F,4.5°C/49°C Non-corrosivesleevefactoryinsta[led in saddle Caution: Thisdeviceis notintended forapplicationsin explosive environments SizesAvailable: Steel Pipe schedules lOthru 40, sizes 2" thru 8" BS 1387 pipe 50mmthru 200mm Note: For copper or plastic pipe use Model VSR-CF ServiceUse: AutomaticSprinkler NFPA-1 3 One ortwofamilydwelling NFPA-130 Residential occu pa ncy up tofourstories NFPA-1 3R National FireAlarm Code NFPA-72 Optional: CoverlamperSwitch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the wateruiow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2' (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7770-0328:0001 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill witlherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PS10 PS-10A PS-bOA WFSR-F PS100 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2, 3", 4') and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1', 1-1/4", 1-1/2" and *2 steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8'. Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V& operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Poff.FR SUPERVISORY SWITCH oESEWAYoKEVAE OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 UL and CSFM Listed, FM Approved, NYMEA Accepted Dimensions: 6.19"L X 2.25W X 5.88"H 15.7cm LX 5.7cm W X 14.6cm H Weight: 2 lbs. (.9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1 -. One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40°F to 140°F (-40°C to 60°C) NEMA 4 and NEMA 6P Enclosure (lP67) Indoor or outdoor use (Not for use in hazardous locations. See Bulletin No. 5400705 OSYS-U-EX for hazardous locations). Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use Automatic Sprinkler N EPA-i 3 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, con- taining one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging ii size from 2" to 12". They will mount on some valves 2s small as 1/2". The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or resporsible party. Replacement or additional cover screws and hex keys are available. See ordering information on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal Compar 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 905-882-1833 www.potlersignal.com PRINTEDINUSA MKT.#8820004-REVM PAGE 10F4 6199 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 0 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0010 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witlherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W PS-120A OSYSU-2 PTS-B OSYSU-1 PIVS-B US-S WLS PTS-C *RBVS WLS-S PS-40A OSYS-B PMS GVS PCVS-1 TTS-W PCVS-2 PS4O PS12O RATING: INSTALLATION: n accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 *Rev 5-17-2007jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS M14TEO, Program Coordinator Fire Engineering Division 7'4ffi I I jversic1c 5ystm D esig ns Inc. YOUR RELIABLE DKATf NC 5ERVICE COMPANY I Office! fAX# .Gö4.&5o Cell # SOS.5 I 8.8050 E.-mail youngrd@rnaiI.com I FILE COPY Fire Alarm System - Certificate of Completion This form must be completed and available to the tire inspector upon their arrival to conduct a final fire alarm system performance test. Location of Fire Alarm System Name: Avellino La Costa CityiState/Zip: CarlsbaLCA 92009 Telephone it: Contact: General Information: .-hum System Installer KPS Power[ lomc fess: 760 S. Rochcstcr Ave. Suite Il CityiSateiZip: Ontario, CA 91761 Telephone U:_909-9X0-9222 Contact: Service Department ,\!arm Panel Nlanuf.,cturvr:Firelite Model: FLMS-5UD-3 Alarm Panel Location: Outside of Electrical Closet Elect Panel Name /1 House Panel HP Circuit No.: #4 - SPRINKLER SYSTFIS Inspectors'rest Valve location: fró+ dow. rime ofOpening of Test Valve to tlarm: .42 Seconds Main Drain 'rest hate: N/A - Static Pressure: N/A PSI Residual Pressure (Flowing N/A 190. 1 Normal Operating Pressure of System: N/A Date of List Fire Pump Test (lf.tpphicable): N/A FILE COPY harm And Detection Equipment L Fire Alarm Control luid YES NO NI. A. Doc Doci the panel indicate noimal conthhon? U. Are all indicating lamps in working order? x C D'i Ilic troihk fight I!pratc? D. Duvi ihg 'i,hnt.e switt.1i &r.sse! L. Dotes she panel have Battery Batkuip1 x F. Are the Batteries properly charged? x U. Dv the ,;utel have Zone Disable Capahilitiei'? x DEVICES QTY. QrY. TESTED CLE ANED OK Re,nic ;I)s)tII)i;Itl)I4 Zones Manual Pull Siations A. Coded FL N4in-Coded I I X Detectors A. Phutuekurte I I X ii 1miasicn C._ihernial D. _Flame 1'. D11'.1 I Rate of'Rise G. Fi.ed_Tnirature A Atitlible Al:inn's A. Bell 13. Siren 110111 Him_&_SirnF 7. Water Flow Silchie A. PtthlkT1,g I I X I I X Li_I'.i_V. '). l food Mom iii 1• Knox 13ii 1 1 X Comments: Did the Alarm Monitoring Company Receive the Signal? . Yes O No Date:6:].1 -1 .1 Time: I PM Is the Alarm System sack in Service: Yes E3 No E3 ALARM INSTALLER CERTIFICATION 1l O*t V representing the Firm KIPS PowerHome, have installed the Fire Alarm System at the iocatlofl detailed above In accordance with the approve:d: plans and have tried the system in accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. Alarm InstaIIer:j2 kA _________ . I Date:_ 1 L EWE COP\ Fire Alarm System - Certificate of Completion This form must be completed and available to the nrc inspector upon their arrival to conduct a final fire alarm system performance tess. Location of Fire .\lann System .-kuTn System Installer N.une: Aveltino La Costa PId Nimc: KPS PowcrlFomc 1 lress: 760 S. RochcstcrAve. Suite 13 City/State/Zip: _Carisba&CA 92009 CitySateiZip: Ontario, CA 91761 Telephone H; Telephone Ii: 909-90-9222 Contact: Contact: _Service dment a;eneralInformation: Alarm Panel Manufictwr:Firelite _ - Model: FLMS-5UD3 i\lami Panel Location: Outside of Electrical Closet Elect Panel Name /# House Panel HP Circuit No.: #4 SPRINKLER SYSTEMS inspector 'rest Valve Location:__ _i6't'k otoO(. Time of Opening of Test Valve ti Marm: _.42 Seconds Main Drain 'rest Hate: N/A Static Pressure: N/A Residual Pressure (Flowing): _- PSi Normal Operating Pressure n1 System: ._._ Date of Last Fire I'unip Test (lf.pgdkabte: rry I I,- ILL i .i:: .brm And Detection Equipment Fi reAlarm C,ruO Ruici YES No A. Doci fflc pme indicate normal condirnw? U. Arc all indicatingImps in working ankr x C i)'e ih., froibk GO- it 4qer;Ifc Ui. Ducs 1114:SWIdB ()l)CVe? L Dot the parn1 have Bat.eiy Backup? x F. Are the Baivevics prly igcd? G. Dvei thepwivO have Zone )shle CpahiHe'? IMiViCES QTY. Qry. TESTED CLEANED (.)K Rein le AHflU1UItI ) Zones Maiival Pull Stations A. Coded H. Non-Coded I I X A. liul.trie 1 11 X C. Thermal I.). _Flame F. I_hiLt - F. G._Fi.ed_renii;lure A Audible Itnii A. Hell II._Siren C. 110111 F)._Horn_&_Sirnh. 7.Wuter_ Flow _S_iiche A. P;itli1kT1,e I I X 13 Prc'uire_l:c W Funper Sitdici I I X U._I'.IV. '). lad Sem m. Kim flii't 1 1 X Comments. Did the Alarm Monitoring Company Receive the Signal? . Yes 0 No Date: (ii. .i Time: ( ç7Y Is the Alarm System back in Service: Yes 13 No ) I ALARM INSTALLER CERTIFICATION {4 o*t eLI(V1) V reoresentinff the Firm KPS Poweri-lome. have installed the Fire Alarm System at the location detailed above in accordance with the approve &i I plans and have tried the system In accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. 1 . I Alarm Installer: Date: t a9/7 ? bQFILE copy Fire Alarm System - Certificate of Completion This form must be completed and available to the fire inspector upon their arrival to conduct a linal tire alarm system performance test Lucation of Fire Alarm System N,une: Avellino La Costa P Afdre7L174. :'1tutJi5.r City/State/Zip: CarlsbadCA 92009 Telephone H:________________________ Contact: ;eneralInformation: .-larm System tn5lalkr Nkmic: KPS Powcr[tome 4&lrcss:760 s. Rochester Ave.Suite B CityiSate'Ztp: Ontario, CA 91761 Telephone Ii: 909-980-9222 Contact: _Service Department ,\!axm Panel Manuticturer:Firelite Model: FLMS.5UD.3 ,lann Panel Location: Outside of Electrical Closet Elect Panel Name J# House Panel HP Circuit No.: #4 SPRINKlER SVSTFIS inspectors Test Valve Location: t,°1i)S_F'4'vk otoot. Time of Opening of Test Valve to Marm: _.42Seconds lain Drain Test Hate: - N/A Static Pressure: N/A Residual Pressure (Flow irtg):.._- N/A also Normal Operating Pressure o(Sysfem:.._N/A PSO Date of Last Fire Pump Test tlf .tpplieabtej: r'rr iLL.L1 arrn,nd Defection EiijJpment Fire ,cU.flrr (;1rO and YES No A. Doi Docs olic panel lcae normal condi'w? U. Arc all indicating kIJflJ5 in working order' x ( Duci ihe irouhl fid-ma 4rarc U. 1AICS 111C ilenee stikh 1r.e? L Does the panel have Battery Backup? .re the Batteries propirly charged? Dk,4.N the p;ueO he /one l)shVe Cipahiie? DEVICES QTY. QrY. TEST ED CLEANED OK Remote Zones Manual Pull Stations - A. Coded Non-Coded I X A. lIJJeIe*.ittL I I X II. ii',.atkni - Thermal Elaine R,teoERise Fi.ed renipralure 6 .tJuhJe tin,is - U.Siren C. Iloni I).Hirn &Sitnh 7.'V;iIer Flow Sètcli' A.PithJkType I I I X U. I'I.V. ).l food Mom lip.Nni..fli, 1. 1. X Comments: Old the Alarm Monitoring Company Receive the Signal? IX Yes 0 No Data: lime: t çç Is the Alarm System sack In Service: ' Yes[] No g.., ALARM INSTALLER CERTIFICATION 4 Jtt 21JY'Y1 k( .representing the Firm KPS PowerHome, have installed the Fire Alarm System at the location detailed above In accordance with the approve plans and have tried the system in accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. I Alarm Installer: Date: 17/f / b919 7c4.f(i$4'L' FILE COPY Fire Alarm System - Certificate of Completion This form must be completed and available to the lire inspector upon their arrival to conduct a final lire alarm system performance tea. Location of Fire Alarm System M;um System Installer Nune: Avellino La Costa PI 1S Name: [(PS Powcrl[ome Addrei 6q/•z5. ('7I3 k1lrvss: 760 S. RochcstcrAvc. Suite 13 CityiStateiZip: Carlsbad,CA 92009 -' CityiSateiZip; Ontario, CA 91761 fekphone ii: Telephone M: 909--980-9222 Contact: Contact:_ Service Deertment General Information: Alium Panel Manuticturcr: Firelite Model: FLMS.5UD3 Alarm Panel Location; Outside of ElectricalCloset Elect Panel Name /#House Panel HP Circuit N(D.: #4 SPRlNkL(K SYSTEMS litpectori 'lest Valve location: - tsd\1 Z' Fmk otoo!'. Time of.Opening of Test Valve to Marm: .42 Seconds Main Drain rest Date: N/A Static Pressure: -- N/A PSI Residual Pressure (l'lowing):.......... N/A Normal Operating Pressure otSystem: N//t PSO Date of East Fire Pump Test (If .tpgdkabk): FILE COP' tui Arm A nd Defection Equipment J. Fire Alarm CuRflrtA Panel YES U) N/. A. l)ci 111c pine I d;cae nrmd COndihOT& Ii. Arc all indicating 1aups in working order? ( Dvei ilie iro%I!Pk 4!rer;Ife? U. )s llh: ikne sihl L Does the pmil have Battery Bkiip? .re the Oaffenes prnpirly charged? Does ihe ,;,guO have lone Ds.hle ipahiies? MAKES QTY. QFY. TESTED CLEANED OK Zones Manual Pull Stations A. Coded FL Non-Codcd I I X 11(Jtift I X EL I ni,ancu% Thermal I). flame - J'IateofRi'e ri.cd rnj;eraiurc 4 \tthhJc ;\linns - A. Hell I X IL Siren l fug-lo Horn & Sirni'e 7. W;iicr 1kSwIldici \. P;itldk T1e I I X . rinpSsiidiei - I I _____ X 1'1V. ') IInodSMem Knox Hon x x x x x Comments. Did the Alarm Monitoring Company Receive the Signal? . Yes 0 No Date: i.I. .1.1 Time: I s the Alarm System Back On Service: Yes 13 No fl wwe w www wwwmwwm.awmww..suwe3wwww.wwwww.w.cewwwu.au...w wee. we ALARM INSTALLER CERTIFICATION , 4 £ítt (2tJY'Yl) (IC , representing the Firm KPS PowerHome, have Installed the Fire Alarm System at the location detailed above in accordance with the approvEL plans and have tried the system in accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. Alarm i nstalier:JJ1 Date: t I I