HomeMy WebLinkAbout6947 TOURMALINE PL | 6949 TOURMALINE PL; ; FA110062; Permit4/10/25, 3:18 PM FA110062 Permit Data City of Carlsbad Fire Alarm Permit 6947 TOURMALINE Job Address: PL Permit Type: FALARM Parcel No: 2131126102 Lot #: 0 Reference No.: Permit No: FA110062 Status: ISSUED Applied 8/29/2011 Approved: 9/1/2011 Issued: 9/1/2011 PC #: Inspector: Project Title: K&B AVELLINO LA COSTA BLDG 12 MONITORING SYSNEW MFD (2-UNIT CONDO) CB102339, C131 02239 Applicant: Owner: KPS ALARM INC 760 ROCHESTER STE B ONTARIO, CA 909-260-0900 Fees ($) Add'I Fees ($) Total ($) Balance ($) 275 0 275 0 about:blarik 1/1 F1T\\\ D o 0.1 d Project Building #12 Avellino 6947,6949 Tourmaline Place Carsibad CA Alarm system contractor 760 S. Rochester Avenue, Suite A 6 Ontario, Ca 91761 Office 909 292-0215 Fax 909-980-4477 St Lic. C10 No803708 APPR 6 D AS SUBUUTTED frC FIRE !)EPAR141 -MT I I I I I 1 I .,. I I I I I I MS-5UD-3(E)/MS-1 OUD-7(E) Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACP5 is compatible with System Sensors microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow, devices, tamper switches, and other normally-open contact devices. Refer to Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MS-5UD-3E and the MS-i QUD-7E offer the same features as the MS-5UD-3 and MS-10UD-7 but allow connection to 220/240 VAC. NOTE: Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and the 220/240 VAC ver- sions of these panels. Features DF-52416:A A3-20 FireLITeALarm.s by Honeywell Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-i OUD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-i OUD-7. Optional Dress Panel DP-51050. Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Optional 8 zone Relay Module ANN-RLY. Optional Remote Annunciator ANN-80. Optional Remote Printer Gateway ANN-S/PG. Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). I Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter) I . Style B (Class B) IDC (Initiating Device Circuit) - McI in. - five irir I - MS-i OUD-7 - ten lDCs. PROGRAMMING AND SOFTWARE: Style Y (Class B) NAC (Notification Appliance Circuit) - spe- Can be programmed at the panel with no special software cial application power or additional equipment. - MS-5UD-3 - four NACs. I Programmable Make/Break Ratio. - MS-10UD-7 - four NACs. Upload/Download (local or remote) of program and data via - • Notification Appliances may be programmed as integral DACT. I - Silence Inhibit. USER INTERFACE: - Auto-Silence. Built-in DACT (Digital Alarm Communicator/Transmitter). - Strobe Synchronization for System Sensor, Wheelock, Integral 80-character LCD display with backlighting and keypad. . .. :Gentex, Faraday, or Amseco devices, - Selective Silence (horn-strobe mute). I Real-time clock/calendar with automatic daylight savings - Temporal or Steady Signal. dJus.tments. - . - Silenceable or Nonsilenceable. ANN-Bus for connection to remote annunciators. DF.52416:A - 06/18/07 - Page 1 0t4 Left Side Door = 19.26' (48.92 cm) Backbox = 19.0" (48.26 cm) Right Side Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 220 VAC, 50 HZ, 0.54 A MS-lOUD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.90 A MS-10UD-7E (FLPS-7 Power Supply): 220 VAC, 50 HZ, 2.20 A Wire size: minimum 14 AWG (2.00 mm) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.1 Minimum Battery Size: 7 AH Initiating Device Circuits - TB4 (and TB 6 on MS-10UD-7 only): Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7) Alarm Zones 6 - 10 on TB6 (MS-lOUD-7 only) Supervised and power-limited circuitry Operation: All zones Style B (Class B) Top Depth = 5.207" (13.23 cm) _______ Depth _ = Door 16.821" (42.73 cm) 5.257",. Backbox = 16.65' (42.29 cm) 43353 cm) Bottom Cabinet measurements Page 2 o14 - DF-52416:A•06/18/07 Normal Operating Voltage: Nominal 20 VDC Alarm Current: 15 mA minimum Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL-listed) Standby Current: 2 mA Refer to Fire-Lite Device Compatibility Document for listed compatible devices Notification Appliance Circuits - T135 (and TB 7 on MS- lOUD-i only): Four NACs Operation: Style V (Class B) - Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3(E), 2.5 A maximum per NAC; 7.0 A for MS-lOU D-7(E), 3.0 A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to Fire-Lite Device Compatibility Document for compati- ble listed devices Form C Relays - TB8: Relay 1 (factory default programmed as Alarm Relay). Relay 2 (factory default programmed as fail-safe Trouble Relay). Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - TB2: Remote power supply synchro- nization output, only required for the MS-5UD-3(E). 24 VDC nominal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Ordering Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). MS-5UD-3E: Same as above with 240 VAC FLPS-3 power supply. MS-lOUD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-10UD-7E: Same as above with 240 VAC FLPS-7. OPTIONAL MODULES CAC-5X: Optional Style Z (Class A) Converter Module. Con- verts Style B (Class B) Notification Appliance Circuits to Style D (Class A) and Style V (Class B). Connects to J2 on the MS- 5UD-3(E) and MS-10UD-7(E) main circuit board and to J7 on NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. ANN-LED: Mounts in the DP-51050 dress panel and provides three LEDs for each zone: Alarm, Trouble, and Supervisory. ANN-RLV: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-SIPG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-110: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. DF-52416:A .06/18107 - Page 3014 SYSTEM SPECIFICATIONS System Capacity Annunciators......................................................................8 Electrical Specifications - MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ. 1.OA MS-lOUD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.9 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50/60 HZ, 0.54 A MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/ 60 HZ, 2.2 A Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - 20.00" (50.80 cm.) high —22.5" (57.15 cm.) wide —8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:214 NFPA Standards The MS-5UD-3(E)/MS-10UD-7(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). FireLite® Alarms and System Sensor® are registered trademarks of Hon- eywell International Inc. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. ________ We cannot coverall specific applications or anticipate all requirements. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52416:A - 06/18/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ' OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0214 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) I LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 I Email: Brian.Reynolds2@Honeywell.com DESIGN: Model MS-5UD-3, MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-i OUD-3, MS-10UD-3E, MS-10UD-7, MS-10UD-7C AND MS10-UD-7E Fire alarm control units. The I MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the I FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. Refer to listee's I data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module I FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module I ANN-LED; Annunciator Module ANN-RLY; Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and I indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not I NOTE: exceed 30 seconds. 04-23-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division (a FireifferALarms www.firelite.com GENERAL The Fire-Lite BG-12 Series is a cost-effective, feature- packed, non-coded series of manual fire alarm pull sta- tions. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series fea- tures a variety of models including single- and dual-action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down posi- tion to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (lDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). Terminal numbers are molded into the backplate, elimi- nating the need for labels. June 30, 2000 DF-52004 F-050 BG-I2 Series Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices c®us LISTED S711 <>M APPROVED Switch contacts are normally open. Can be surface (with SB-b) or semi-flush mounted. Semi-flush mount to a standard single-gang, double- gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the popular BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. California State Fire Marshal 7150-0075:184 (except BG-I2LOB) This document is not intended to be used for installation purposes. We try to keep oupfodue"nformation up to ate a i._1o_gIJfJ1 (ions or anticipate all requirements. All specifications are subject to change without ___________ notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Niorthford, d I I .1 ___________ Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ENGINEERING&MANIJF4CTIJRINC Back:(888) 388-3299. Made in the U.S.A. DF-52004 - Pagel of 2 CONSTRUCTION PRODUCT LINE INFORMATION Cover, backplate and operation handle are all molded Model of durable polycarbonate material. BG-12s Cover features white lettering and trim. Red color matches System Sensor's popular BG-12 SpectrAlertTM horn/strobe series. OPERATION BG-12L Description Single-action pull station with pigtail connec- tions, hex lock. Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking per- sons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bot- tom as a visible flag. Resetting the station is simple: in- sert the key or hex (model dependent), twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: 52004tb11 .ep BG-12 SB-la Height. 5.500 inches 5.500 inches (13.97 cm) (13.97 cm) Width- 4.121 inches 4.125 inches (10.4673 cm) (10.4775 cm) Depth. 1.390 inches 1.375 inches (3.5306 cm) 1 (3.4925 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger." Stations shall be suitable for surface mounting on matching backbox SB-b; or semi- flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. NOTE: The words "FIRE/FUEGO" on the BG- 12LSP shall appear on the front of the station in white letters, approximately 3/4" high. Page 2 of 2 - DF.52004 BG-12LSP Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-12LOB Same as BG-12L with "outdoor use" listing. Includes WBB outdoor backbox, and sealing gasket. (FM Pending) 1.390" (35.306) 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2@Honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LA0, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-Psi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Models Available Two-Wire Models 2W-B 2WT-B 2-wire standard. 2-wire standard with thermal Four-Wire Models 4W-B 4-wire standard 4WT-B 4-wire standard with thermal Accessories 2W-MOD2 2-wire loop test/ maintenance module SENS-RDR Sensitivity reader RT Removal/ replacement tool A77-AB2 Retrofit adapter bracket I I Product Overview 1I Plug-in detector line - mounting base System Sensor's i3" series smoke detectc-rs represent a significant advancement in Included conventional detection. The P family is founded on three principles: Installation ease, Intelligence, and Instant inspection. Large wire entry port In-line terminals with SEMS screws Installation ease. The 13 line redefines installation ease with its plug-in design. This allows an installer to pre-wire thr bases included with the heads. The large Mounts to octagonal and single-gang wire entry port and in-line terminals proidc ample room for neatly routing the backboxes, 4-square backboxes, or wiring inside the base. The base accommadates a variety of back box mount- direct to ceiling ing methods as well as direct mounting with drywall anchors. To complete the installation, 13 heads plug-in to the base with a simple Stop-Drop 'N Lock Stop-Drop IN Lock" attachment to base action. Removable detector cover and chamber Intelligence. 13 detectors offer a number o intelligent features to simplify for easy cleaning testing and maintenance. Drift cornpenra:ion and smoothing algorithms are standard with the 13 line, to minimize nuisance alarms. When connected to the Built-in remote maintenance signaling 2W-MOD2 loop test/maintenance modul, or a panel equipped with the i3 protocol, 2-wire 13 detectors are capablt of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleanii. This signal is indicated via an LED algorithms located at the module and :he panel. Tc read the sensitivity of 13 detectors, the SENS-RDR is a wireless device that displays the sensitivity in terms of percent Simplified sensitivity measurement per foot obscuration. Wide angle, dual color LED indication Instant inspection. The 13 series provides wide angle red and green LED indica- tors for instant inspection of the detector condition, indicating: normal standby, Loop testing via EZ Walk feature out-of-sensitivity, alarm, or freeze trouble conditions. When connected to the Built-in-test-switch 2WQD2io-ap_tes.t/maiutena.aceioJuI_o1a_pa.nei.tJithe_LprrnncDI, the EZ Walk loop test feature is available on 2-wire 13 detectors. This feature ® zE3'0 MEA MSFM verifies the initiating loop wiring by p:cv ding LED status indication at each detector. approved approved LISTED S911 3011446 7272-1209:210 290-01-E 2093 Architect/Engineer Specifications Smoke detector shall be a System Sensor 0 Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (model 2W-B, 4W-B) or a combination photoelectric/ thermal (model 2WT-B, 4WT-B) with ther- mal sensor rated at 135°F (57.20C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Miii.: 8.5V Max.: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage LED M with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring con- nections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug- in type. The detector shall have a nonii- nal sensitivity of 2.5% per foot nominal as measured in the UL smoke box. The detector shall he capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. Standby Current 2-wire: 50 pA maximum average 4-wire: 50 pA maximum average The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (model 2WT-13, 4WT-B) conditions. When used in conjunc tion with the 2W-1%40D2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Peak Standby Current 2-wire: 100 pA 4-wire: n/a Maximum Alarm Current Alarm Contact Ratings 2-wire: 130 mA limited by control panel 2-wire: n/a 4-wire: 20 mA @12V, 23mA @ 24V 4-wire: 0.5 A @ 30V AC/DC on LEO Mode Green LEO Red LEO Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Physical Specifications Operating Temperature Range Sensitivity Mounting 2W-B and 4W-6: 32°F-120°F (OC-49C( 2.5%/ft. nominal 3N-inch octagonal back box 2WT-B and 4WT-B: 32F-100F (0°C-37.8°C) 4-inch octagonal back box Input Terminals Single gang back box Operating rrumdity Range 14-22 AWG 4-inch square back box with a plaster ring 0 to 95% RN non-condensing Dimensions (including base) Direct mount to ceiling Thermal Sensor 5.3 inches )127 mm) diameter 135F (57.2C) fixed 2.0 inches (51 mm) height Freeze Trouble Weight 2WT-B and 4WT-B only: 4F (5CC) 6.3 oz. (178 grams) Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-8 Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4WT-B Yes 4-w, re 20 mA @ 12V, 23mA @ 24V Model Description 2W-MOD2 2-wire loop test / maintenance module SENS-RDR Sensitivity reader FIT Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor - Far East System Sensor - India 342 2.0767 P-li: 85.22.194-9003 Rh-944246-37-47-7-O-x--2-7-OO St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05.0318-005.6/04.#1280 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC Page 1 of 1 LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-13 and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4WT-B are 4-wire detectors. Models 2W1-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division PRODUCT DATA SHEET .- - - — - - -- -- - - - 1530 Shields Drive - - — Waukegan, IL 60085 1h/8I/8If/p91fr/8II2ZZ Toll-Free (800) 323-9355 Fax: (847)689-1192 PART NUMBER: 51013 DESCRIPTION: 14 AWG STRANDED TYPE THHNITHWN FIXTURE WIRE CONSTRUCTION: This cable consists of one bare copper conductor with integral insulation and jacket. APPROVALS: UL Standard 62 and Subject 758 APPLICATION: Fixture Wire, Appliance Wiring Material, Canada T90-Nylon, Canada TWN75 Construction Parameters: Conductor Stranding Insulation Material PVC Insulation Thickness Nylon Insulation Thickness Insulated Conductor Diameter Number of Conductors Approximate Cable Weight Electrical & Environmental Properties: 14 AWG Bare Copper 19/0147" PVC/Nylon 0.016' Nom. 0.005 Nom. 0.112 Norm 16.4 Lbs/1M' Nom. Temperature Rating -200C to 105°C Operating Voltage 600V Max Impedance 41.08 Ohms/IM' DC Resistance per Conductor @ 2cPC 2.52 Ohms/1M' Insulation Color Varies Legend (Surface Ink Print) BARON 14 AWG (UL) E101736 THHN OR THWN 600V GASOLINE & OIL RES I OR AWM STYLE 1316 & 1408— C(UL)T90 NYLON OR TiNN75 FT1 On special orders, the customer will accept all roil lengths and *1- 10 percent of total order requested The information presented here is, to the best of our knowledge, true and accurate Since conditions of use are beyond Coleman cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and Conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name_______________________________________ Customer Approval Specification Issue Date: October 24, 2005 1-800-323-9355 (Phone) 1-647-689-1192 (Fax) 51013 Designed By: PEP I 0 2005 Coleman Cable, Inc. I PRODUCT DATA SHEET — -- ra -- - — 1530 Shields Drive I Waukegan, IL 60085 I Toll-Free (800) 323-9355 Fax: (7) 689-1192 PART NUMBER: 97814 I DESCRIPTION: 14/2 SOLID FIAT FPLR ZIP CABLE CONSTRUCTION: This cable consists of two bare copper conductors laid flat with an integral insulation and jacket. APPROVALS: UL Standard 1424, NEC Articles 760. I APPLICATION: Power Limited Fire Alarm Circuit Cable Intended for Riser Applications Construction Parameters: Cable Cross-Section I Conductor 14 AWG Bare Copper Stranding Solid Insulation Material PVC Insulation Thickness 0.030" Nom. 0/ Insulated Cable Dimensions 0.124" x 0.253' Nom. I Number of Conductors 2 Approximate Cable Weight 37.0 Lbs/1M' Nom. Flame Rating UL 1666 Riser Flame Test Electrical Properties: Temperature Rating -20°C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz #REFl Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @20°C 2.54 Ohms/1M' Nom. Insulation/Jacket Colors White, Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 * 14 AWG 2/C (UL) TYPE FPLR SUN RES On special orders, the customer will accept all factory lengths and 10 percent of total order requested. The jacket is sequentially footmarked, The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable, Customer Name_______________________________________ Customer Approval Specification Issue Date: December 27, 2005 I 1-800-323-9355 (Phone) 1-847-689-1192 (Fax) 97814 Designed By: PEP © 2005 Coleman Cable, Inc. PRODUCT DATA SHEET — - -- -- — --_MW — - — - _ — S 8I8I/Iff iZ'I/ Iiiiz PART NUMBER: 98181 DESCRIPTION: 18/2 SOLID FPL FT1 MID-CAPACITANCE CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in General Purpose Applications for Addressable Fire Alarm Systems 1530 Shields Drive Waukegan, IL 60085 Toll-Free (800) 323-9355 Fax: (847)689-1192 Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness Insulated Conductor Diameter Number of Conductors Lay Length Separator/Wrap Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating Electrical Properties: 18 AWG Bare Copper Solid Polypropylene 0.006" Nom. 0.052" Nom. 2 4.00" Nom. None PVC 0.014" Nom. 0.132" Nom. 16.0 Lbs/1M' Nom. UL 1581 Vertical Tray Flame Test Temperature Rating -200C to 60°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 19 pF/ft Nom. Capacitance Between Conductors to Shield @ 1 KHz DC Resistance per Conductor @20°C 6.32 Ohms/1M' Nom. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) E100315 • 18 AWG 2/C (UL) TYPE FPL SUN RES - C(UL) TYPE CM FT1 —ADDRESSABLE FIRE CABLE On special orders, the customer will accept all factory lengths and */-10 percent of total order requested. The jacket is sequentially footmartred. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control, all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of product(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman cable. Customer Name Customer Approval Specification Issue Date: December 27, 2005 1-800-323-935 (Phone) 1-847-689-1192 (Fax) 98181 Designed By: PEP 612005 Coleman Cable, Inc. PRODUCT DATA SHEET - -- -- -_-_ -Am 1530 Shields Drive — — Waukegan, IL 60085 7I81/49VF41/8/I11Z Toll-Free (800) 323-9355 Fax: (847) 689-1192 PART NUMBER: 81804 DESCRIPTION: 18/4 SOLID FPLP FT6 CABLE CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Construction Parameters: Cable Cross-Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.006" Nom. Insulated Conductor Diameter #NIA Number of Conductors 4 / Lay Length Parallel Jacket Material Low Smoke PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter #N/A Approximate Cable Weight #N/A Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical Properties: Temperature Rating -20°C to 75°C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz #NJIA Capacitance Between Conductors to Shield @ 1 Kl-lz DC Resistance per Conductor @ 200C #N/A Insulation Colors Black Red Green Yellow Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81804 18 AWG 4/C C(ETL) US (ETL CODE) TYPE FPLP 75C -- TYPE CMP FT6 On special orders, the customer will accept all factory lengths and +1- 10 percent of total order requested The jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman cable's I control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sate of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. I This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. I Customer Name Customer Approval Date Signed Specification Issue Date: November 21, 2005 1-800-323-9355 (Phone) Designed By: PEP 1-847-689-1192 (Fax) 81804 © 2005 Coleman Cable, Inc. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. 7161-1236:0102 Page 1 of 1 CATEGORY: 7161 --CABLES-FIRE PROTECTIVE SIGNALING LISTEE: Coleman Cable1530 Shields Dr, Waukegan, IL 60085 Contact: Howard Caccia (847) 672-2000 Fax (847) 689-9116 Email: hgccoleman-cable.com DESIGN: Type FPL, FPLR and FPLP fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Art. 760 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. NOTE: Formerly 7161-0756:100 *Rev. 06-15-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct HV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 31, " ~F@v Q77 U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8". LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted Service Pressure: Upto450 PSI Minimum Flow Rate forAlarm: 10GPM Maximum Surge: 18FPS Contact Ratings: Two sets ofSPDT (Form C) 15.O Amps at 125/25OVAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2"conduit Environmental Specifications: S uitablefor indoororoutdoor use with factory installed gasket and die-casthousing. NEMA4/lP54 Rated Enclosure -use with appropriate conduit fitting - Temperature Range: 40°F/120F,4.5°C/49°C Non-corrosive sleeve factory installed in saddle Caution: This device is not intended forapplicationsin explosive environments SizesAvailable: Steel Pipe schedules l0thru 40, sizes 2" thru 8' BS 1387 pipe 50mmthru 200mm Note: For copper or plastic pipe use Model VSR-CF ServiceUse: AutomaticSprinkler NFPA-1 3 One ortwofamilydwelling NFPA-13D Residential occupancy up to four stories NFPA-1 3R National FireAlarm Code NFPA-72 Optional: CoverTamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the waterfiow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. I Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 Phone: 800-325-3936/Canada 905-882-1833 www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV P PAGE 1 OF 2 MEG. #5400761 - 3/99 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0001 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWTCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill witlherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-13 WFSR-C WFSPD-B P510 PS-10A PS-100A WFSR-F PS100 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models maybe used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2', 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1/2", 3'). Model VSR-SF for use on 1', 1-1/4", 1-1/2" and *2fl steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2' through 8'. Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer tolistee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division (E)S POff ER OSYSU-1 1 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 UL and CSFM Listed, FM Approved, NYMEA Accepted Dimensions: 6.19"L X 2.25W X 5.88"H 15.7cm L X 5.7cm W X 14.6cm H Weight: 2 lbs. (.9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40°F to 140°F (-40°C to 60°C) NEMA 4 and NEMA 6P Enclosure (1P67) Indoor or outdoor use (Not for use in hazardous locations. See Bulletin No. 5400705 OSYS-U-EX for hazardous locations). Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories N EPA-i 3R National Fire Alarm Code NFPA-72 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, con- taining one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most Os & Y valves ranging in size from 2" to 12. They will mount on some valves as small as 1/2. The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover screws and hex keys are available. See ordering information on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). I Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 631464161 • Phone: 800-325-3936/Canada 905-882-1833° www.pottersignal.com PRINTED IN USA MKT. #8820004 - REVM PAGE 1 OF 4 6199 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 0 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0010 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witlherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, PIV, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W PS-120A OSYSU-2 PTS-B OSYSU-1 PIVS-B TTS-S WLS PTS-C *RBVS WLS-S PS-40A OSYS-B PMS GVS PC VS-i TTS-W PCVS-2 PS4O PS12O RATING: INSTALLATION: n accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 *Rev 5-17-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division I I Kiversicic System Designs I nc I YOUR RELIABLE DT!NG 5ERVICE COMPANY I Office /AX#5t.G4.3&5& E-mail youngrsi@gmal.corn I I Fire Mann System - Certificate of Completion This form must be completed and available to the fire inspector upon their arrival to conduct a final fire alarm system performance test. Location of Fire .\larm System Alami System Installer N.inie; Avellino La Costa Name: KPS Powerl-lome Address: jjCtt.tCL 1LL1 T U riviii M ) ddr,is:760 S. Rochester Ave. Suite 13 CityiState/Zip:Carlsbad.CA 92009 CityiSateiZip: Ontario, CA 91761 '(dephone d'. Ii 909-980-9222 Contact: Contact: Service Department (;eneral Information: Alarm Panel Ntanuficturcr: Firelite FL-MS-5UD-3 Alarm Panel Location: Outside of ElectricalCloset Elect Panel Name /#House Panel HP Circuit No.: #4 SPRINKLER SYSTEMS lntpectors 'Fest Valve location: , . Q (1 j, c q I li'M 'j.Jjj 1 (& ( Time 01 Opening of Test Valve to Alarm: .42 Seconds Main Drain Test Date: N/A Static Pressure: N/A PSI Residual Pressure (Flowing): N/A rsi Normal Operating Pressure of System: N/A PSI Date of Last Fire Pump Test (If tpplicahle): N/A P1 Alarm And Detection Equipment 1 . Firi, Alarm €.ontrol Rutel YES No NI. A. Does the panel indicate normal cnndihoi& B. Arc all indicating kunps in working or&r? x U Dvei Ilie tftfllllk tkhr vreratel x 1). Do the silence switch tq)erate? L. Does the panel have Battery Backup? x Are the Batteries properly charged? R'es the p;niel have Zone Disable Capabiliü& x DEVICES QTY. Qry. TESTED CLEANED OK . Rinotc :\ItI)IIIIUat )I 4 3. Zones 4. Manual Pull Stations Coded Non-Coded I I X 5. Detectors A. I'll"tuelcolic X EL Ionization C. _Thermal I). _Flame 1. DfIct )._Rate of Rise vt G. Fixed _rnialure (. .Aiithibk :l:inns A, 13411 13. Siren C. 1101-11 D. Hum&_Strobe 7. 'vV;jkr Flow Sw ii&be A. P;itldk Type I I X s. riinp Ssitchc A. O.S.&Y I I X Il._I'.I.V. hood Sieni Ill. Knox 1311 1. 1 X Comments: Did the Alarm Monitoring Company Receive the Signal? . Yes 0 No TwAk DNV( '_______ Is the Alarm System Back In Service: Yes[] No ALARM INSTALLER CERTIFICATION I, tijt 'A . representing the Firm KPS PowerHome, have installed the Fire Alarm System at the location detailed above in accordance with the approved plans and have tried the system in accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. Alarm Installer: l\I4t6U,t,UP Date:- 6141 7otg~116 copy Fire Alarm System - Certificate of Completion This Form must be completed and available to the fire inspector upon their arrival to conduct a final fire alarm system performance test. Location of Fire ,\Iarm System Nune: Avellino La Costa (BI142-9) Atldress:j./1LECL VICfl 1i' Li riuyLL ) CityiStateiZip: Carlsbad,CA 92009 Telephone i:______________________________ Contact: General Information: Alarm PanelManufacturer: Firelite Alarm System Installer N:trnc: KPS PowerElome (ldress 760 S. Rochester Ave. Suite 13 CitytSatcZip: Ontario, CA 91761 Telephone /I: 909-950-9222 Contact: Service Department Model: FLMS5UD3 Alarm Panel Location: Outsideof ElectricalCloset Elect Panel Name /#HousePanelHP Circuit No.: #4 SPRINKLER SYSTEMS Inspectors Feit Valve Location: '.S Q'LA (,tN1I \ Mo. v't ? Time of Opening of Test Valve ((P Alarm: .42 Seconds Main Drain 'rest Date: N/A Static Pressure: N/A PSI Residual Pressure (Flowing): N/A PSI Sormail Operating Pressure of System: N/A Ps[ Date of Last Fire Pump Test (If Applicable): N/A P1 ;SJirm And Detection Equipment I Fire Alarm (..unlrol ['.UteI YES NO N/. A. I )ocs she panel inihcate normal conditrnn? B. Are all indicating lamps in working order? x ( D e' the troulik fit--fit erare? Ii. tk the 'iils.mee switdi operate! L Does the panel have Battery 8uikiip? x F. .re the Batteries properly charged? U. [)ves the p;tnd h.te /3C Disable ('apab1lflIe0 x DEVICES QTY. QTY. TESTED CLEANED OK Zones MunuaJI Pull Stations A. Coded B. Non-Coded 1 1 X A. l'hiutodeeirc I I X [). [onrtattnn C. 'l'hcrmal Ii Ebine F. I )ii 'Rteofl'ie Fixed rnj;uture .. \,ittibk AI:irul.% A, HAM I I X 13. Siren C. 1km D. Horn & Stinhe 7. \V;iter Flow sm,11clici A. PathtlkTspe I I X H Praiie 1% pe S. Fainper Ssnchei A. o.s.&Y -I I x U. l'.I.V. X V Comments: Did the Alarm Monitoring Company Receive the Signal? . Yes 0 No Is the Alarm System Back In Service: Yes 0 No ALARM INSTALLER CERTIFICATION ,, -kt&-\-1 CfAJ O \ ' , representing the Firm KPS PowerHome, have installed the Fire Alarm System at the location detailed above in accordance with the approved plans and have tried the system in accordance with the manufacturers specifications and appropriate NFPA requirements and Local Ordinances. Alarm Installer: Date:tfI 1)1