Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5600 AVENIDA ENCINAS; ; FPC2023-0137; Permit
111 It II1li41121I11A1 Laty of Carlsbad Print Date: 02/12/2025 Permit No: FPC2023-0137 Job Address: 5600 AVENIDA ENCINAS, CARLSBAD, CA 92008-4452 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2100905000 Valuation: $8,223,037.68 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: DEV2022-0059 Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 08/10/2023 Issued: 10/19/2023 Finaled Close Out: 04/04/2024 Final Inspection: INSPECTOR: Robinson, Jarrod Cheung, Nathaniel Salcedo, Felix Project Title: 5600 AVENIDA ENCINAS TI Description: VUORI -REVISION TO SPRINKLER PLANS FOR TI CONSISTING OF RELOCATING DROPS FOR NEW WALLS/ROOMS CONFIGURATI( (309 HEADS) (REV. 1 TO ADD SUITES 170-195 TO SCOPE) (REV 2 ADDED SCOPE IN SUITES 100 & 150) (REV 3 ARCH. CONST. CHANGES) Applicant: FPContractor: A AND D FIRE SPRINKLERS INC A AND D FIRE SPRINKLERS INC BEN LEDESMA 7130 CONVOY CT 7130 CONVOY CT SAN DIEGO, CA 92111-1019 SAN DIEGO, CA 92111-1019 (858) 277-3473 (858) 277-3473 FEE AMOUNT FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE Hourly Services (first hour) $200.00 FIRE NFPA 13 or 13R System > 100 heads $774.00 FIRE Plan Review (per hr - Regular Office Hours) $255.00 FIRE Plan Review (per hr - Regular Office Hours) $170.00 FIRE Plan Review (per hr - Regular Office Hours) $170.00 Total Fees: $2,769.00 Total Payments To Date: $2,769.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov A Division of The Hiller Companies, Inc. VUORI 5600 AVEN IDA ENCINAS CARLSBAD, CA. 92008 FIRE SPRINKLER SUBMITTAL PRODUCT DATA ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. TABLE OF CONTENTS FIRE SPRINKLERS PIPE&FITTINGS HANGERS & BRACING I 1. SPRINKLERS Victaulic® FireLock Model FL-QRIC Standard Coverage, Quick Response Concealed Pendent Sprinklers, K5.6 (8.1) As-tau-1icr 41.03 4 1.0 PRODUCT DESCRIPTION - QUICK RESPONSE CONCEALED PENDENT SPRINKLERS ________________________ SIN V5606 V38022 V38082 ORIENTATION Concealed Pendent Concealed Pendent Concealed Pendent K-FACTOR' 5.6 Imp-/8.1 S.I. 5.6 Imp./8.1 S.I. 5.6 Imp./8.1 S.I. CONNECTION ½" NPT/15mm BSPT ½" NPT/15mm BSPT W NPT/1 5mm BSPT MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) 300 psi (2068 kPa) ESCUTCHEON Concealed Concealed Concealed GLOBE RE-DESIGNATED GL5606 - - GLOBE EQUIVALENT - GL5604 GL5605 AVAILABLE WRENCHES SPRINKLER 1" ADJ Concealed V38 Concealed V38 Concealed PENDENT CLEAN ROOM GASKET SPRINKLER 1' ADJ Concealed V38 Concealed V38 Concealed PENDENT 1 U Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: UL/FM: 7psi/48 kPa/.5 bar Temperature Rating: See tables in section 2.0 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. 2 V3802 and V3808 are listed as Standard Response when installed using clean room gasketed coverplate. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 41.03 16369 Rev E Updated 06/2023 © 2023 Victaulic company. All rights reserved. 1 X, 'tauIic t,,rrnlI,e mm 2.0 CERTIFICATION/LISTINGS 1' UK 'U CP LPS 1186: Issue 3.1 CertILPCB Ref. 104b/06 APPROVALS/LISTINGS SIN V5606 Cover Plate V3802 V3808 Cover Plate Nominal K Factor Imperial 5.6 - 5.6 5.6 - Nominal K Factor 5.1.2 8.1 - 8.1 8.1 - Orientation Pendent - Pendent Pendent - Escutcheon Concealed - Concealed Concealed - APPROVED TEMPERATURE RATINGS F°/C° 135eF,575C 135eF/57eC 1350F,57uC 135eF,57*C 135°F/57°C 155F/68C 135F/57eC I 155°F168°C 155FI68C 155°F/68°C 135°FI5TC cULus 175°F/795C 155°F/68°C 175eF,79eC 1755F/79°C 165°F1745C 2000F/93eC 155FI68°C 200°F/93°C 200eF/930C 165°F/74C 155°F/68°C 135°F157°CI 1550F,68eC 155°F/68°C 135°F/575C FM Standard Response Only 175°F/79°C 155F/68C 175eFI79OC - 135°F/57°C i 65°F/74°C 2000F/93eC 155eF,680C 200°F193°C 165eFI74eC 1555F/68°C 138F/59C LPCB - - 175F/79C - 165F/74C 200F/93C 165FI74C 155F/68C 138F/59C CE - - 175°F/795C - 165eF/740C 200F/93C 165F/745C CCC 155eFI68oC 135°F157°C K ZSTDY - - 2000FI93eC ' 135°F/57°C 1165eF/74eC APPROVALS/LISTINGS WITH CLEAN ROOM GASKET SIN V38023 V38083 Cover Plate Nominal K Factor Imperial 5.6 5.6 - Nominal K Factor SI.2 8.1 8.1 - Orientation . Pendent Pendent - Escutcheon Concealed Concealed - APPROVED TEMPERATURE RATINGS F°/C5 c US 135F/57°C 155°F/68°C 175°F/79°C 200F/93C 135F/57*C 155uF,68uC 175F/79C 200eF/930C 135F/57*C 135°FI5TC 165eF/74eC 165uF/74uC 2 For K.Factor when pressure is measured in Bar, multiply S.I. units by 10. Listed as standard response when installed clean room using gasketed coverplate. NOTES Listings and approval as of printing. New York City Acceptance - All UL Listed and/or FM Appwroved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the OTCR Rule. These sprinklers are required to be vented. Installations with a positive pressure air plenum above the housing are not permitted. c®us LISTED I 41.03 16369 Rev E Updated 06/2023 @ 2023 Victaulic Company. All rights reserved. ram 2 jtauIic• / victaulic.com 3.0 SPECIFICATIONS — MATERIAL Deflector: Bronze Bulb Nominal Diamter: 3.0 mm Load Screw: Brass Pip Cap: Brass Spring Seal: PTFE coated Beryllium nickel alloy Frame: Brass Concealed Cup: Steel Cover Plate: Steel Lodgement Spring: Stainless Steel Pin: Stainless Steel Installation Wrench: Ductile Iron Sealing Gasket: White nitrile (CLEAN ROOM USE ONLY) Cover Plate Finishes: Chrome plated White painted Flat black painted Custom painted NOTE For cabinets and other accessories refer to separate sheet. 4.0 DIMENSIONS I 2M6768 mm 2W760 mm Hole in ceiling Cup --JI Lodgement Spring_\ Pip cap and spring seal 'N Bulb Frame Pin .—... Typical ceiling _, 2W/61 mm Load Screw—.. 1W/48 mm Cover plate -1,._u::::1 mm __________ '— Finished surface V3802, V3808 V3802, V3808 41.03 16369 Rev E Updated 06/2023 0 2023 Victaulic Company. All rights reserved. 3 j4ltIUIiC V8I 4 mm WI 'mm mm nm t victaulic.com 4.0 DIMENSIONS (CONTINUED) 2W/60 mm 2"/51 mm Hole in ceiling 1 WI - 48 mm Cup Pip cap and spring seal Lodgement spring -owa Bulb Frame Load screw 21/4"/6969 mm 117mm Pin Deflector -._.. Typical ceiling Cover plate 21/."/70 mm j Finished surface ----t wi 4mm V5606 Finished surface I Activated Position V5606 4"I102 mm 2W173 mm Seismic Coverplate Large Coverplate V5606 V5606 41.03 16369 Rev E Updated 06/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 4 X. 0 Ant a -U, ii C r victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS WARNING m Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -67°F/-55°C. 41.53: Victaulic® FireLocknu Series FL-SR/C 1-40: Victaulic FireLockTM Automatic Sprinklers Installation and Maintenance Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods at use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all ether Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, 41.03 16369 Rev F Updated 06/2023 © 2023 Victaulic Company. All rights reserved, victaulic.com j4tiuiic Worldwide I tqCL70 Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp172 General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/6 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IAL)tLi* The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT 1Y323. . . . Pendent 5.6K, 1/2 in. NPT Technical Data Approvals See Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi/2 (80,6 LPM/bar''2) Temperature Rating See Table A Finishes Sprinkler: See Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze Page 1 of 4 SEPTEMBER 2022 TFPI72 2-7/8' (73,0 mm) DIA. TFPI72 Page 2 of 4 t Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16 (11,1 mm) Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN 6* 5 I 7/16 : (111,11 mm) MAKE-IN (50,8 mm) _______ NOMINAL " 2' - I 1-3/8 (50,8 mm) - I (34,9 mm) WFF 1/2' NPT** DEFLECTOR* STYLE 150r20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 2-7/8 DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm)' 5/8' (15,9 mm) SPRINKLER FITTING 3 ___ 3/8±5/16" (9,5±7,9 mm) FLUSH MOUNTING 1/8" J SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4' 1/2" (12,7 mm) (7,9±6,4 mm) \ ____________ FLUSH 1 ________________________________ I \ J I MOUNTING 1/8" SURFACE/ - \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyesterc 5.6 1/2 in. NPT UPRIGHT (TY313) and PENDENT (TY323) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue ________________ RECESSED PENDENT (TY323) Figures 48 and 5b 135°F (57°C) Orange 1,2,3,4,7 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01 -E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. EAC Approved. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15(1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT( 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench as shown in Figure 2. Apply the W-Type 6 Sprinkler Wrench to the wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench as shown in Figure 3. Apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI72 Page 4 of 4 P/Na 77_XXX_X_XXX SIN I F SPRINKLER I I FINISH 370 1 5.6K UPRIGHT (1/2 in.NPT) TY313 r1 NATURAL BRASS PURE WHITE (RAL9010)a POLYESTER SIGNAL WHITE (RAL9003) POLYESTER I5 I JET BLACK (RAL9005) I POLYESTER I 9 I CHROME PLATED Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 371 j 5.6K PENDENT (1/2 in.NPT) I TY323 Notes: a. Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I TEMPERATURE RATINGS 135 135°F (57°C) 155 155-F (68-C) 175 I 175-F (79-C) 200 200°F(93°C) 286 286-F (141-C) Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed EscUtch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 i11 ?- 02022 Johnson Controls. All rights reserved. All specifications and Other Information shown were Current as of document revIsIon date and are subject to Change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are r*gIsIn,od rodn,vad,v of CeSSnA P1,0 ProlocIlon A5soCi*Iivfl Controls TEFLON Is ufrvdenrmk of The Chonooro Conrp*ny FC. LLC tqC170 Worldwide Contacts I www.tyco-fire.com TFPI 72 Change History Appendix ISSUE DATE NOTES Page 1, updated QR code and URL; Page 3, Table A, added EAC Approved; Page 4, changed corporate 09-22 address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 I Telephone +1-401-781- _____________ 8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 I_Telephone +1-215-362-0700. 11-21 Added QR code and URL to allow convenient access to electronic version from printed document. Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer 08-18 stating specifications and information subject to change without notice; Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300. 02-18 Changed Recessed Pendent (TY313) to Recessed Pendent (TY323) in Type column of Table A. 07-17 Added Table A to organize Laboratory Listings and Approvals; Changed existing Part Number Selection table designation to Table B; Added Jet Black (RAL9005) Polyester sprinkler finish option. 02-14 Added note to indicate sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion Resistant Sprinklers; Added LPCB Approval. 01-13 Changed note in Ordering Procedure Part Number Selection table to indicate special order ISO thread sprinklers may be ordered by adding an I suffix code to Part Numbers, formerly described as prefix. 12-12 Rev A Added C-UL Listings and reference to Intermediate Level sprinkler data sheets. 12-12 New Technical Data Sheet TFP172 describes Series TY-FRB Quick Response 5.6 K-factor (K80) Stan- dard Coverage TY313 Upright and TY323 Pendent and Recessed Pendent Sprinklers 1467 Elmwood Avenue, Cranston, RI 02910 llelephone +1-401-781-8220 Johnson 00'~~# 0 2022 Johnson Controls. All rights reserved. All specifications and other information shown were currant as of document revision data and are subject to change without notice. Controls Worldwide I tqcco Contacts www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 112 K and 140 K Upright and Pendent Extended Coverage Light and Ordinary Hazard IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp220 General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules, such as NFPA 13, for a maximum cov- erage area of 400 ft2 (37,2 m2) as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age sprinklers used in ordinary hazard occupancies, Series EC-11 and EC-14 Extended Coverage Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combus- tible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. Series EC-11 and EC-14 Extended Cov- erage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprinklers. These tests have shown that the pro- tection provided is equal to or more effective than standard coverage spray sprinklers. Corrosion-resistant coatings, where applicable, help extend the life of copper alloy sprinklers beyond that which occurs when exposed to corrosive atmospheres. Although corrosion-resistant coated sprinklers passed standard corrosion tests of the applicable approval agencies, this testing is not representative of all pos- sible corrosive atmospheres. Conse- quently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity should be considered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers TY5137 ............Upright, 11.2K TY5237............Pendent, 11.2K TY6137 ............Upright, 14.0K TY6237...........Pendent, 14.0K TY5137 is a re-designation for C5137, G1894, and S2510 TY5237 is a re-designation for C5237, 01893, and S2511 TY6137 is a re-designation for C6137, G1896, and S2610 TY6237 is a re-designation for C6237, G1895, and S2611 Technical Data Approvals Series EC-11 and EC-14 Sprinklers UL and C-UL Listed FM Approved EAC Approved Note: For complete sprinkler approval information including corrosion-resis- tant status, see Table A. The approvals apply to the service conditions indi- cated in the Design Criteria section. Escutcheons The Style 60 Two-Piece Flush Escutcheon, as shown in Figure 4, is UL Listed for use with the Series EC-11 and EC-14 Pendent Sprinklers. Page 1 of 8 SEPTEMBER 2022 TFP220 ESCUTCHEON PLATE SEATING SURFACE 1 2 S 16" -4 nm) WRENCH 3/4" FLAT NPT** CROSS PENDENT SECTION 2-7/16° (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT TFP22O Page 2 of 8 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) ASSEMBLY Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 in. NPT Diséharge Coefficients K = 11.2 GPM/psi½ (161,3 LPM/bar½) K = 14.0 GPM/p5i½ (201,6 LPM/bar½) Temperature Ratings See Table A Finish Sprinkler: See Table A Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical Characteristics Frame ............................Bronze Button............................Bronze Sealing Assembly . Beryllium Nickel w/TEFLON Bulb ........................Glass (3 mm) Compression Screw ................Bronze Deflector...........................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indi- cated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applica- ble. See Tables A, B, and C, for more information. UL and C-UL Listing Requirements Series EC-11 and EC-14 Extended Coverage Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and haz- ard group for all sprinklers in the design area. Series EC-11 and EC-14 Extended Coverage Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceil- ing construction as defined and permitted by NFPA 13; for example: Unobstructed, combustible or noncombustible, ceiling con- struction with a deflector to ceiling/roof deck distance of 1 t 12 in. (25 to 300 mm). Obstructed, non-combusti- ble, ceiling construction with a deflector location below struc- tural members of 1 to 6 in. (25 to 150 mm) and a maximum deflector to ceiling/roof deck dis- tance of 22 in. (550 mm). Series EC-11 and EC-14 Extended Coverage Sprinklers, specifically tested and listed for non-combus- tible obstructed construction, are permitted to be used within truss- es or bar joists having non-com- bustible web members greater than 1 in. (25,4 mm) when apply- ing the 4 times obstruction crite- ria rule defined under "Obstruc- tions to Sprinkler Discharge Pattern Development". To prevent cold soldering, the minimum allowable spacing be- tween Series EC-11 and EC-14 Ex- tended Coverage Sprinklers is 8 ft (2,4 m) for upright sprinklers and 9 ft (2,7 m) for pendent sprinklers. Series EC-11 and EC-14 Extended Coverage Sprinklers are to be in- stalled in accordance with all oth- er requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For exam- ple, obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees Series EC-11 and EC-14 Extended Cov- erage Upright and Pendent Sprinklers (TY5137, TY5237, TY61 37 and TY6237) have a UL and C-UL Specific Applica- tion Listing for use under concrete tees when installed as follows: 1. Stems of the concrete tee con- struction must be spaced at less than 7.5 ft (2,3 m) on center but more than 3 ft (0,9 m) on center. The depth of the concrete tees must not TFP22O Page 3 of 8 Hazard Type Temperature Bulb Liquid Sprinkler Finish6 Natural Brass I Chrome Plated I Polyester Lead Coated Upright K=11.2 (TY5137) 135°F (57°C) Orange 1, 2, 3", 4, 5 155°F (68°C) Red 175°F (79°C) Yellow Light Pendent Table B describes UL and C-UL K11.2 (TY5237) K14.0 (TY6237) __________________ 200°F (93°C) Green 1, 2, 4, 5 1,2, 4, 5 286°F (141°C) Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) 135°F (57°C) Orange 1,2,3,4,5 N/A Sensitivity Rating Table C describes FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow With Style 30 Escutcheon 1, 2, 4, 5 200°F (93°C) Green 286°F (141°C) Blue Ordinary Upright K=11.2 (TY5137) K14.0 (TY6137) Pendent 135°F (57°C) Orange 1, 2, 3, 4, 5 1, 2, 3, 4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Table B describes K=11.2 (TY5237) 1, 2, 4, 5 UL and C-UL Sensitivity Rating K=14.0 (TY6237) 286°F (141°C) Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) With Style 30 or 40 135°F (57°C) Orange 1, 2, 4, 5 N/A Table C describes FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green NOTES 1. Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) Approved by Factory Mutual Research Corporation (FM) Approved by the City of New York under MEA 177-03-E EAC Approved Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers N/A ° Not Available Frame and Deflector only ** Pendent only TABLE A LABORATORY LISTINGS AND APPROVALS Area Light Hazard Ordinary Hazard ftxft Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - QR OR QR QR QR 14 x 14 Style 30 Recessed - - - - - OR OR QR OR QR Style 40 Recessed - - - - - OR OR OR OR OR Upright or Pendent OR* OR* QR* OR* QR* SR SR SR SR SR 16 x 16 Style 30 Recessed QR* QR* OR* OR* QR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR* OR* OR* OR* QR* SR SR SR SR SR 18x18 Style 30 Recessed QR* OR* QR* QR* QR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR° QR- QR* SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed QR* QR* OR* SR* SR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR NOTES ° OR = Quick Response SR = Standard Response ° N/A =Not Applicable Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-fl OR EC-14 SPRINKLERS (SEE TABLE D FOR PERMITTED K-FACTOR/AREA COMBINATIONS) TFP22O Page 4 of 8 HC-1 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type K-factor Style Response Min Max Min Max Noncombustible Unobstructed, 11.2 EC Pendent or 10 20 100 400 Up to 30 Noncombustible Obstructed, or 14.0 EC Upright Combustible Unobstructed Noncombustible Unobstructed, 11 2 EC . Pendent 10 20 100 400 Up to 30 Noncombustible Obstructed, or 14.0 EC Recessed Combustible Unobstructed Style 30 10 20 100 400 Upto30 Combustible Obstructed 11.2 EC Pendent or Upright Quick 10 20 100 400 Up to 30 Combustible Obstructed 11 2 EC . 14.0 EC Pendent Recessed Style 30 10 20 100 400 Over 30 and upt045 Noncombustible Unobstructed 11.2 EC 14.0 EC Upright HC-2 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type K-factor Style Response Min Max Min Max 10 20 100 400 Up to 30 Noncombustible Unobstructed, 11.2 EC Pendent or Quick 10 20 100 400 Up to 30 14.0 EC Pendent or Combustible Unobstructed 10 16 100 256 Over 30 and 11.2 EC 14.0 Upright up to 45 EC HC-3 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type K-Factor Style Response Min Max Min Max 10 16 100 256 Up to 30 11.2 EC Upright 10 20 100 400 Upto30 14.0 EC Pendentor Noncombustible Unobstructed, Combustible Unobstructed Upright Quick 10 16 100 256 Over 30and up to 45 11.2 EC, 14.0 EC Upright NOTES The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0,8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi (1,2 bar). For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-Factor/Area Combinations. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-11 OR EC-14 SPRINKLERS exceed 30 in. (762 mm). The maxi- mum permitted concrete tee length is 32 ft (9,8 m). However, where the concrete tee length exceeds 32 ft (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 ft (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 in. (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 in. (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. FM Approval Requirements Series EC-11 and EC-14 Extended Coverage Upright and ,Pendent Sprin- klers are to be installed in accor- dance with the applicable FM Loss Prevention Data Sheet for limited use in buildings of specific roof construc- tion and for the protection of certain specific ordinary hazard (non-storage and/or non-flammable or combustible liquid) occupancies. Information pro- vided in the FM Loss Prevention Data Sheets relates to, but is not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to- ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with FM requirements before proceeding with design. TFP22O Page 5 of 8 Description Area ft x ft Light Hazard 0.10 GPM/ft2 __________ __________ Group I Ordinary Hazard 0.15 GPM/ft2 ___________ Group II Ordinary Hazard 0.20 GPM/ft2 GPM PSI GPM PSI GPM PSI 14 x 14 30 7.2 30 7.2 39 12.1 TY5137 16 x 16 30 7.2 39 12.1 51 20.7 (K=11.2) Upright 18 x 18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 14 x 14 30 7.2 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 TY5237 (K=11.2) Pendent 18x18 33 8.7 49 19.1 65 33.7 20x20 40 12.8 60 28.7 80 51.0 14x14 N/A N/A 39 7.8 51 13.3 TY6137 16x16 N/A N/A 39 7.8 51 13.3 (K=14.0) Upright 18x18 N/A N/A 49 12.3 65 21.6 20x20 N/A N/A 60 18.4 80 32.7 14 x 14 37 7.0 39 7.8 51 13.3 16x16 37 7.0 39 7.8 51 13.3 TY6237 (K=14.0) Pendent 18 x 18 37 7.0 49 12.3 65 21.6 20x20 40 8.2 60 1 18.4 80 32.7 NOTES 1 ft=0,3048m lft2 =0,093m2 1 GPM = 3,785 LPM 1 psi = 0,06895 bar 1 GPM/ft2= 40,74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS Installation TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 286°F (141°C) tempera- ture ratings. A leak-tight 3/4 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 10 to 20 lb-ft (13,4 to 26,8 N.m). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate, or other applica- ble escutcheon, over the sprinkler pipe threads and with pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. For upright or pendent sprin- klers, wrench-tighten using only the W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli- cable sprinkler wrench, as shown in Figure 5 or Figure 6, to the sprinkler wrench flats, as shown in Figure 1. INTERNAL -.-- DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE I CLASS 150 MALLEABLE - IRON REDUCING -2 SPRINKLER FITTING MOUNTING 1/8 SURFACE - (3,2 mm) I CLOSURE 3/4" NPT 2 5/161 (58,7 mm) -MOUNTING 1 - 13/16 (46,0 mm) PLATE - 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. (57,2 mm) FACE OF SPRINKLER FITTING: 3/8" (9,5 mm) ABOVE TO 1/8" (3,2 mm) BELOW MOUNTING SURFACE I L ESCUTCHEON PLATE SEATING SURFACE: 1/4 (6,4 mm) ABOVE TO 1/2 (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT FIGURE 4 SERIES EC-11 AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 IN. TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 6 of 8 - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2 (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4 (6,4 mm) FACE OF (57,2 mm) -H SPRINKLER ç) MOUNTING FITTING PLATE /I ,_ MOUNTING 1/8 SURFACE (3,2 mm) . CLOSURE TY5237 or 1-3/8 (34,9 mm) 1Y6237 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 IN. TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. 5/8±1/4u (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) MOUNTING SPRINKLER FACE OF (57,2 mm) T FITTING PLATE FITTING 77 MOUNTING SURFACE (3,2 mm) CLOSURE TY5237 or 1-3/8" (34,9 mm) TY6237 7/8 (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON "FITTING SIDE TOWARDS SPRINKLER FITTING /\ WRENCH RECESS / (END "A") FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - LJL WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH TFP22O Page 7 of 8 PIN 51 - XXX - X - XXX SIN F SPRINKLER TEMPERATURE FINISH' RATING 893 11.2K Pendent TY5237 1 NATURAL BRASS 135 135°F (57°C) 894 11.2K Upright TY5137 SIGNAL WHITE 155 155-F (68-C) 4 (RAL9003) - POLYESTER 895 14.0K Pendent TY6237 - JET BLACK (RAL9005) 175 175°F(79°C) POLYESTER 896 14.0K Upright TY6137 - 200 200°F (93°C) 7 LEAD COATED Escutcheon ordered separately. NOTES: 286 286°F (141°C) OPEN indicates the sprinkler assembly 9 CHROME-PLATED - without glass bulb, button, and sealing assembly. 000 OPEN2 TABLE SERIES EC-11 AND EC-14 UPRIGHTAND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation section, for more information. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards recognized by the Approval agency, such as NFPA 25, in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-11 or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temperature rating, (specify) finish, P/N (from Table E) Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Flush Escutcheon, Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify**) **Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 TFP22O Page 8 of 8 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 02022 Johnson Controls. All rights reserved. All specifications and other Information shown were Current CO of document revision dale and are subject to Change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA ore registered trodomerku of National Fine Protection Association; TEFLON iso trudomarh of The Chornours Company FC. LLC Controls tqco® Worldwide I Contacts I www.tyco-fire.com TFP22O Change History Appendix ISSUE DATE NOTES Page 1, updated QR code and URL; Page 1, Approvals sub-section, added EAC Approved; Page 8, 08-22 changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 I Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700. 11-21 Added QR code and URL to allow convenient access to electronic version from printed document. 06-19 Added pendent orientation for 11.2 K-factor variant in Hazard Class 2 (HC-2) Ceiling Height up to 30 feet to Sensitivity Rating for FM Approval Table C. 10-18 Updated Table B to identify which K=14 Upright sprinklers are not Quick or Standard Reponse. Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer 08-18 stating specifications and information subject to change without notice; Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300; Changed metric conversion factor in Table D to 1 ft = 0.3048 m, formerly 1 ft = 0.348 m. 12-17 Expanded applicability of laboratory listings and approvals relative to hazard, sprinkler type and tem- perature rating. 11-14 Added Jet Black (RAL9005) sprinkler finish to Part Number Selection Table E. Corrected sprinkler orientation in Design Criteria, UL and C-UL Specific Application Listing Require- 09-14 ments for Installation under Concrete Tees sub-section, pendent EC-11 and EC-14 sprinklers are also subject to NFPA 13 discharge criteria requirements when installed with deflectors located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottoms of concrete tee stems. 06-14 Corrected SIN numbers shown in Figure 1 caption. 05-14 Corrected Sensitivity Ratings in Table C. Changed ceiling heights per FM Approval to limited to 45 feet; formerly over 30 feet; Added option for 02-14 Open sprinklers to Ordering Procedure (Open indicates a sprinkler assembly without Bulb, Button or Sealing Assembly). 11-13 Added Sensitivity Ratings to Ordinary Hazard applications in Table B, formerly Not Applicable (N/A); Added Flow and Pressure criteria to Table D. 02-12 Corrected typographical errors in coverage areas provided in Table D. 09-11 Updated to reflect current legal and department standards. 07-11 Updated patent information. 12-07 Added reference to new UL Listed and FM Approved Style 60 Two-Piece Flush Escutcheon. 02-07 Changed UL and C-UL Listied sensitivity rating of operating temperatures up to 200°F (93°C) to to quick response for ordinary hazard 14' x 14' coverage areas; formerly standard response. Added UL and C-UL Listed installation criteria for non-combustible web members greater than 1 inch 09-04 within trusses and or bar joists; Added UL and C-UL Listed installation criteria for pendent sprinklers located beneath concrete tees. 04-04 Added NYC Approved; Changed recessed sprinkler wrench to W-Type 22 which accommodates pro- tective Sprinkler Strap, formerly W-Type 4. 02-04 Updated Listings and Approvals; Added Style 30 Recessed Escutcheon to Table B under ordinary hazard for UL and C-UL; Added NYC Approved to Table A as applicable. 04-03 Corrected FM sensitivity rating in Table for ordinary hazard recessed style to Not Applicable (N/A), for- merly Standard Response (SR). Page 1 of 2 TFP220 CHANGE HISTORY APPENDIX, CONTINUED Page 2 of 2 ISSUE DATE NOTES 01-03 Added new Tyco Fire & Building Products masthead. 10-02 New Technical Data Sheet TFP220 describes Series EC-11 and EC-14 Extended Coverage Pendent and Upright Sprinklers. 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 Johnson 02022 Johnson Controls. All rights reserved. All specifications and other information Shows were current anal document revision data and era subject to change without notice. Controls 2. PIPE & FITTINGS M LL 1Y100SF_' APPROVALS AND SPECIFICATIONS ASTM A135, Grade A ASTM A795, Type E, Grade A Pressure rated to 300 psi Underwriters Laboratories- United States of America Underwriters Laboratories-Canada Factory Mutual NFPA-13 NFPA-13R NFPA-14 CIVIL DEFENSE APPROVAL- United Arab Emirates Made in the United States of America UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, preaction and deluge sprinkler systems. LEED v4 Certified SCHEDULE 10 & 40 SPRINKLER PIPE SUBMITTAL DATA SHEET FINISHES AND COATINGS Schedule 10 & 40 Sprinkler Pipe receives an OD mill coating of water-based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. Schedule 10 & 40 Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. EG2 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. Schedule 10 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM Al 23 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION Every length of Bull Moose fire sprinkler pipe features large, easy-to- read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. j 0.0. (in) - - I.D. (In) - - - Empty Weight (lb/ft) - - - water Filled Weight (lb/ft) - -- CAR.* - - Pieces per Lift - - - 0.0. (in) I.D. (in) Empty Weight (lb/It) - - - water Filled weight (lb/ft) - - - C.R.A. - - Pieces per Lift g U' e 01b IJZD 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.091 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 1.800 2.518 3.053 4.223 5.893 7.951 11.796 23.038 40.086 15.27 9.91 7.76 621 4.92 13.54 2.50 1.158 1.805 91 61 61 37 30 19 19 10 7 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4,026 1.680 2.270 2.720 3.660 5.800 7.580 10.800 2.055 2.918 3.602 5.114 1.875 10.183 16.316 1.00 1.00 100 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VlZY **Not Eddy Guard II treated/Not produced by BMT SUBMITTAL INFORMATION Project I Contractor[ Engineer [ Specification Reference Date [ System Type Locations [ 1 Comments (ID Schedule 10- Black 0Schedule 10 - Hot Dip Galvanized 0Schedule 40-Black 0Schedule 40- Hot Dip Galvanized EULL]V[OOSETU BE .COM 11 YiJ i1 I I Victaulic® FireLockTM Installation-Ready1M Rigid Couplings X Ant-a —U1 i C r Style 009N and Style 109 10.64 Patented 1.0 PRODUCT DESCRIPTION Available Sizes Style 009N: 11/4 - 12/DN32 - DN300 Style 109: 11/4 - 4/DN32 - DN100 Pipe Material Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic For exceptions reference section 6.0 Notifications Maximum Working Pressure Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) to 365 psi/2517 kPa Function Joins carbon steel pipe with grooved ends conforming to publication 25.01 Provides a rigid pipe joint designed to restrict axial or angular movement 2.0 CERTIFICATION/LISTINGS USTED LPS 1219 ISsee 3.1 Cert/LPCB Ref. 104-la/36 EN 10311 Regulaoon ( EU) No. 305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. virt,iIir mm 10.64 07072 Rev R Updated 10/2021 © 2021 victaulic Company. All rights reserved. 1 'JtauIiC' victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange coating Red coating (standard for EMEA-1 and Asia Pacific) Optional for Style 009N: Hot Dipped Galvanized per ASTM A123 El Optional for Style 109: Mechanically Galvanized per ASTM B695 (available only in North America and Latin America). Gasket: (specify choice) 0 Grade "E" EPDM (Type A) Vic-Plus Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES Reference should always be made to publication 1-100, Victaulic Field Installation Handbook for gasket lubrication instructions. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) El Standard: Carbon steel oval neck track bolt(s) meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' 1 Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type Ill Finish. 10.64 07072 Rev R updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 '%.JltauIiC victaulic.com 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling ANIN ENO -. Size Maximum Maximum Allow. - Bolt/Nut Dimensions Weight Actual Outside Working End Pipe End Pre-assembled Joint Assembled Approx. X Y X V Nominal Diameter Pressure2 Load2 Separation3 Qty. Size Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DIN mm kPa N mm - mm mm mm mm mm mm kg 1 1/4 1.660 365 790 0.10 3/8 X2 3.13 5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 2.54 2 - M10x51 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.10 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 2 - M10x51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 3/8 X2Y2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7193 3.05 2 - M10x63 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 3/8 X21/2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 2 - M10x63 114 156 102 156 51 1.0 3.000 365 2580 0.12 3/8 X21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 2 M10x63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/8 x2½ 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 1 M10x63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 2 3/8 X2½ 6.00 7.88 5.63 7.50 2,13 2.9 DN100 114.3 2517 25822 4.32 - M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 3/8 X2½ 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 2 - M10x63 152 1.87 137 187 54 1.4 5 5.563 365 8872 0.17 2 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 - M12x76 184 235 171 232 57 2.3 5.250 365 7901 0.17 2 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 M12x76 168 229 162 229 57 2.2 5.500 365 8672 0.17 2 ½ x 3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 - M12x76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 2 '/2X3¼ 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 44469 4.32 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 /2X3'4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 - M12x83 200 254 187 251 57 2.5 6.500 365 12112 0.17 ½X3'/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 2 M12x83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 5/a X4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94863 4.32 2 M16x 101 276 340 1 260 333 64 5.2 8.500 365 20712 0.17 5/aX4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 2 M16x 101 270 337 260 257 67 5.2 10 10.750 300 27229 0.25 7/sX61/2 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121121 6.4 2 - M22 165 349 432 337 435 70 10.3 12 12.750 300 38303 0.25 /8X6Y2 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.4 2 - M22 165 406 483 394 486 70 12.5 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation-Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 \j6taulic victaulic.com p 4.1 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Size Max. Max. Allow. Pipe Bolt/Nut Dimensions Weight Actual Pre-Assembled Assembled Outside Working End End Sep. Approx. Nominal Diameter Pressure Load Maximum Qty. Size YL YB X Z YL YB X Z (Each) inches inches psi Lbs. inches inches inches inches inches inches inches inches inches inches lb DN mm kPa N mm mm mm mm mm mm mm mm mm mm kg 1¼ 1.660 365 790 0.10 1 3/ex2¼ 1.97 2.49 3.17 1.95 1.93 2.59 2.84 1.95 1.5 DN32 42.4 2517 3514 2.54 1 M10x57 50 63 81 50 49 66 72 50 0.7 11/2 1.900 365 1035 0.10 3/px2¼ 2.13 2.60 3.41 1.95 2.1 2.68 3.07 1.95 1.6 DN40 48.3 2517 4603 2.54 1 M10x57 54 66 87 50 53 68 78 50 0.7 2 2.375 365 1617 0.12 3/sx21/4 2.32 2.85 3.76 1.98 2.29 2.95 3.45 1.98 1.9 1 DNSO 1 60.3 2517 7192 3.048 M10x57 59 1 72 96 1 50 58 1 75 88 1 50 0.9 21/2 2.875 365 2370 0.12 ½x2¼ 2.63 3.09 4.29 1.99 2.61 3.15 3.93 1.99 2.1 1 73.0 2517 10540 3.048 M10x57 67 78 109 51 66 80 100 51 1.0 3.000 365 2580 0.12 7Aex21/4 2.68 3.22 4.56 2.03 2.64 3.45 4.22 2.03 2.4 DN65 76.1 2517 11476 3.048 1 1 M11 x69 68 82 116 52 67 88 107 52 1.1 3 3.500 365 3512 0.12 1 3i6x2/4 2.93 3.53 5.13 2.07 2.89 3.78 4.67 2.07 2.7 DN80 88.9 2517 15620 3.048 M11x69 74 90 130 53 73 96 119 53 1.2 4 4.500 300 4771 0.17 7AsX21/4 3.47 4.01 6.03 2.08 3.43 4.22 5.56 2.08 3.5 DN100 1 114.3 2068 21223 4.318 1 M11 x691 88 102 1 153 1 53 1 87 1 107 1 141 1 53 1.6 4 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings/Approvals section of this publication for ratings on other pipe. The allowable pipe separation dimension shown is for system layout purposes only. Style 109 couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES When assembling Style 009N or Style 109 couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings, use FireLock No. 006 end caps containing the 'EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling. There is no interchanging of gaskets or housings between coupling styles. Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. The Allowable Pipe End Separation dimension shown is for system layout purposes only. Style 009N or Style 109 Installation-Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information. 10.64 07012 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 Aic-ta-ulic~ victaul,c.com 5.0 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch. 40 Sch. 10 Sch. 40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON mm bar bar bar bar bar bar 1¼ 1.660 365 365 363 363 363 363 DN32 42.4 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 11/2 1.900 365 365 363 363 363 363 DN40 48.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 2 2.375 365 365 363 363 363 363 DNSO 60.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 365 365 363 363 - 363 21/2 2.875 73.0 2517 2517 2503 2503 - 2500 25 25 25 25 - 25 3.000 3657 - 3638 - 363 363 0N65 76.1 2517 - 25038 - 2500 2500 25 7 - 258 - 25 25 365 365 363 363 363 363 3 DN80 3.500 88.9 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 4.250 - - 363 363 - - 108.0 - - 2503 2503 - - — - 25 25 - - 365 365 363 363 363 363 4 4.500 DN100 114.3 2517 2517 2503 2503 2500 2500 25 25 25 25 25 25 - 3638 - - - 5.250 - 133.0 - - 25038 - - - 258 - - - 2909 - 3638 - 232 363 DN125 5.500 20009 - 25038 - 1600 2500 139.7 209 - 258 - 16 25 290 365 363 363 232 363 5.563 141.3 2000 2517 2503 2503 1600 2500 20 25 25 25 16 25 6.250 - - 3638 - - - 25038 - - - 159 - - 258 - - - 29010 - 3538 - - 363 6.500 2000'0 - 25038 - - 2500 165.1 2010 - 1 258 - - 25 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems 400 F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. ° cULus listed for EN 102204.0mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. 11 With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of '316' on the end face of the bolt. 12 FM approved for 0.188 pipe wall. 13 cULus listed for 0.188 pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 J4taUIi1cf victaulic.com 5.0 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals6 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch. 40 Sch. 10 Sch. 40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON mm bar bar bar bar bar bar 300 365 300 363 232 363 6 6.625 2068 2517 2068 2503 1600 2500 DN150 168.3 20 25 20 25 16 25 290 - 3636 - - - 8.515 2000 - 25038 - - - 216.3 20 - 258 - - - 300 365 30012 363 232 363 8 8.625 2068 2517 206812 2503 1600 2500 DN200 219.1 20 25 1 2012 25 16 25 30013 300 30012 300 - - 10 10.750 206813 2068 206812 2068 - - DN250 273.0 2013 20 2012 20 - - 30013 300 25012 300 - - 12 12.750 206813 2068 172012 2068 - - DN300 323.9 2013 20 1712 20 - 1 - 6 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems 400 F/C and above. Please see the Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. cULus listed for DIN 2458 (EN 10220) 2.6 mm pipe wall. FM approved for BS 1387 (EN 10255) Medium 3.6 mm pipe wall. cULus listed for EN 102204.0mm pipe wall. 10 cULus listed for EN 10255 4.5 mm pipe wall. " With optional stainless steel fasteners, cULus Listed to 175psi/1207 kPa/12 bar and FM Approved to the FM ratings shown in the above table. The stainless steel fasteners have a marking designation of 316 on the end face of the bolt. 12 FM approved for 0.1886 pipe wall. 13 cULus listed for 0.188 pipe wall. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 6 \/(tauIic victaulic.com 5.1 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals15 The information provided below is based on the latest listing and approval data at the time of publication. Listings! Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus FM VdS LPCB Actual Outside Sch, 10 Sch. 40 Sch. 10 Sch. 40 Nominal Diameter psi psi psi kPa F psi psi psi inches inches kPa kPa kPa kPa kPa DN mm bar bar bar bar bar bar 1¼ 1.660 365 365 365 365 232 363 DN32 42.4 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 11/2 1.900 365 365 365 365 232 363 DN40 48.3 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 2 2.375 365 365 365 365 232 363 DN50 60.3 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 21/2 2.875 365 365 365 365 - - 73.0 2517 2517 2517 2517 - - 25 25 25 25 - - 3.000 365 365 365 365 232 363 DN65 76.1 2517 2517 2517 2517 1600 2503 25 25 25 1 25 16 1 25 3 3.500 365 365 365 365 232 363 DN80 88.9 2517 2517 2517 2517 1600 2503 25 25 25 25 16 25 4 4.500 300 365 300 300 - 290 DN100 114.3 2068 2517 2068 2068 - 2000 20 25 1 20 20 - 20 '5 Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems -40° F/C and above. Please see the Victaulic Installation Manual 10 for details concerning when supplemental lubrication is required. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 7 4tauiicr victaulic.com 5.2 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cULus FM psi psi inches kPa kPa Pipe Type DN bar bar 1¼-4 300 EF DN32—DN100 2068 N/A 20 300 300 1 1/4-2EL 2068 2068 DN32 - DN50 20 20 300 ET4O 1'/42 2068 N/A DN32—DNSO 20 00 3 EZF 3-4 2068 N/A DNSO— DN100 20 - 300 300 1'/4-2 EZT DN32 - DNSO 2068 2068 20 - 20 300 FF 1½-4 2068 N/A DN40 - DN100 20 300 300 GL 1¼-2 2068 2068 DN32 - DN50 20 20 3 00 300 1 ¼-4 2068 2068 DN32 - DN100 ____________________________ 20 20 MF 175 175 6 ON 150 1205 1205 12 12 3 00 300 MT 1 ¼-2 2068 2068 DN32 - DN50 20 20 300 MILT 1 V4 2 N/A 2068 DN32 - DN50 20 300 IF 21/2-4 N/A 2068 73.0 mm - DIN 100 20 175 300 WG5, WGSE, WF5, WG7, WG7E, WL7 lh/4 4 1205 2068 DN32—DN100 12 20 300 300 WLS 1¼-2 2068 2068 DN32 - DN50 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZF = EZ-Flow steel pipe manufactured by Northwest Pipe Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT = MLT steel pipe manufactured by Wheatland Tube Co TF = Tea-Flow steel pipe manufactured by Tea-Tube Co. WG5, WG5E, WF5 = WGalweld 5, WGalweld 5E, WFIow 5 steel pipe manufactured by Wuppermann Stahl GmbH. WG7, WG7E, WL7 = WGalweld 7, Wgalweld 7E, WLight 7 steel pipe manufactured by Wuppermann Stahl GmbH WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev B Updated 10/2021 © 2021 Victaulic Company. All rights reserved. iitfiiIit, mm [Si 4tauiicr victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches PSI Psi kPa kPa Pipe Type DN bar bar 1¼-2½ 300 DN32 - 73.0 mm N/A 2068 20 1 1/2-21/2 300 EF DN40 —73.0mm 2068 N/A 20 34 300 300 DN80—DN100 2068 2068 20 20 1¼-2 300 DN32 - DN50 N/A 2068 Easy-Flow 20 3 300 DN80—DN100 N/A 2068 20 1¼-2 300 EL DN32 - DN50 N/A 2068 20 1¼-2 300 300 E140 DN32 - DN50 2068 2068 20 20 1¼-2 300 DN32 - DN50 N/A 2068 EZT _____________________________ 20 300 1Yz-2 DN40 - DM50 2068 N/A 20 1½-4 300 300 FF DN40—DN100 2068 2068 20 20 1¼-2 300 GL DN32 - DN50 N/A 2068 1¼-4 300 300 MF DN32—DN100 2068 2068 20 20 . 1V42 300 300 MT DN32 - DNSO 2068 2068 20 20 1¼-2 300 300 MLT DN32 - DM50 2068 2068 20 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FF = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MLT = MLT steel pipe manufactured by Wheatland Tube Co. TE = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company. All rights reserved. vktiiIirrnm \4taUIiC victaulic.com 5.3 PERFORMANCE (CONTINUED) Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size PressureRating cUlus FM inches psi psi kPa kPa Pipe Type DN bar bar 300 TF 2½ 4 N/A 2068 73.00 mm—DN100 20 300 lh/4 _2 N/A 2068 DN32 - DN50 WG7,WG7E 20 300 3 N/A 2068 DN80—DN100 20 300 WLS 1¼-2 N/A 2068 DN32 - DN50 20 NOTES EF = EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. Easy-Flow = Easy-Flow steel pipe manufactured by Borusan Mannesmann Boru. EL = EDDYLITE steel pipe manufactured by Bull Moose Tube Co. ET40 = Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. EZT = EZ-Thread steel pipe manufactured by Youngstown Tube Co. FE = Fire-Flo steel pipe manufactured by Youngstown Tube Co. GL = GL steel pipe manufactured by Wheatland Tube Co. ME = Mega-Flow steel pipe manufactured by Wheatland Tube Co. MT = Mega-Thread steel pipe manufactured by Wheatland Tube Co. MILT = MLT steel pipe manufactured by Wheatland Tube Co. TF = Tex-Flow steel pipe manufactured by Tex-Tube Co. WG7, WG7E = WGalweld 7 and WGalweld 7E steel pipe manufactured by Wuppermann Stahl GmbH. WLS = WLS steel pipe manufactured by Wheatland Tube Co. 10.64 07072 Rev R Updated 10/2021 © 2021 Victautic Company. All rights reserved. victaulic.com 10 'JtauIic victaulic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designers responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. NOTICE Victaulic does not recommend the use of any furnace butt-welded pipe with sizes 2°IDN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 05.01: Seal Selection Guide 25.01: Original Groove System (OGS) Groove Specifications 1-009N: Installation Instructions FireLock EZTM Rigid Coupling Style 009N 1-100: Victaulic Field Installation Handbook 1-109: Installation Instructions FireLockTM One-Bolt Rigid Coupling Style 109 l-ENDCAP: Victaulic End Caps Installation Instructions I-IMPACT: Impact Tool Usage Guidelines AN-001: Application Notification - Potential Incompatibility of Type F Pipe, Sizes NPS 2 I DNSO and Smaller User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our websife at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, 10.64 07072 Rev R Updated 10/2021 © 2021 Victaulic Company, All rights reserved. victaulic.com 11 X Ac—t a _U1 i C r Victaulic® FireLockTM Fittings AiC--t:a_U1iCr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes 1 ¼ - 8/DN32 - DN200 Maximum Working Pressure Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application FireLocklM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Connects pipe, provides change in direction and adapts sizes or components Pipe Materials Carbon steel 2.0 CERTIFICATION/LISTINGS E (E UK USThO APPROVID CR EN 10311 BS EN 10311 CPR (EU) CPR (UK) No. 305/2011 2019 No. 465 3.0 SPECIFICATIONS - MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: (specify choice) El Orange coating. o Red coating (standard for EMEA-1 and Asia Pacific). 0 Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. t,irt,i ,I;r ran, 10.03 1539 Rev Q Updated 06/2023 © 2023 Victaulic company. All rights reserved. 1 Jtauhc! victaulic.com 4.0 DIMENSIONS l.CtoE.t C I to E C 171- -b to E to L - =0 # No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 90° Elbow 450 Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb ON mm mm kg mm kg mm kg mm kg 11/4 1.660 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 1 ½ 1.900 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.6 2.00 1.4 2.75 2.4 0.88 0.6 0N50 60.3 70 0.7 51 0.6 70 1.1 22 0.3 21/2 2.875 3.00 2.1 2.25 2.2 3.00 3.4 0.88 1.0 73.0 76 1.0 57 1.0 76 1.5 22 0.5 3.000 3.00 2.5 2.25 2.4 3.00 3.8 DN65 76.1 76 1.1 57 1.1 76 1.7 - - 3 3.500 3.38 3.4 2.50 3.1 3.38 5.1 0.88 1.2 DN80 88.9 86 1.5 64 1.4 86 2.3 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 5.9 3.00 4.9 4.00 6.8 1.00 2.4 DN100 114.3 102 2.7 76 2.2 102 3.1 25 1.1 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 7.0 - - 5 5.563 4.88 7.8 3.25 8.3 4.88 15.3 1.00 4.1 141.3 124 3.5 83 3.8 124 6.9 25 1.9 6.250 550 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.1 - - 6.500 5.43 13.0 3.50 9.4 5.50 19.7 165.1 140 5.9 89 4.2 140 8.9 - - 6 6.625 5.50 13.7 3.50 10.4 5.50 20.2 1.00 5.9 DN150 168.3 140 6.2 89 4.7 140 9.2 25 2.7 8.515 6.81 23.1 6.94 33.6 216.3 173 10.5 - - 176 15.0 - - 8 8.625 6.81 27.1 4.25 19.3 6.94 39.0 1.13 12.7 DN200 219.1 173 12.5 108 8.7 176 17.5 29 5.8 10.03 1539 Rev 0 Updated 06/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com \tauIic° victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No. 001 No. 003 Nominal Outside Size Diameter 90 Elbow 45 Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1¼ 1.660 DN32 42.4 - - - - 1½ 1.900 DN40 48.3 - - - 2 2.375 3.5 1.8 8.5 3.5 DNSO 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 23 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 13 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 13 6.3 2.5 6.250 9.4 4.9 - 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 33.0 13.0 216.3 4.0 - 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev Q Updated 06/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZ°' couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLocku No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic® FireLockTM Rigid coupling Style 009N 10.02: Victaulic® FireLock°M Rigid Coupling Style 005H with Vic-Plus°M Gasket System 29.01: Victaulic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer, Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications, All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POF format on our websife at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, 10.03 1539 Rev Q Updated 06/2023 © 2023 Victaulic Company. All rights reserved, victaulic.com 4 J'tauIic Couplings & Cap (Class 150 Standard) El Fig. 1121 Right Hand Coupling LI Fig. 1122 Right & Left Coupling LI Fig. 1124 Cap c()us LISTED APPROVED Fig. 1121 Fig. 1124 J A MMCE7 1is ASC Engineered Solutions ASC Engineered Solutions1M offers the broadest line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASCs strict quality standards. ALL Anvil Class 150 Malleable Iron Fittings conform to ASME B16.3 and unions conform to ASME B16.39. All elbows and tees 3/s" (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval DetaiLs and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutions Representative. See following page for standards and specifications. Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Pressure Temperature Class 150 Class 250 Class 300 PSI/bar PSI/bar PSI/bar -20°-150° 300 500 600 -28.9°-65.6° 20.7 34.5 41.4 200° 265 455 550 93.3° 18.3 31.4 37.9 250° 225 405 505 121.1° 15.5 27.9 34.8 300° 185 360 460 148.9° 12.8 24.8 31.7 350° 150 315 415 176.7° 10.3 21.7 28.6 400° 110 270 370 204.4° 7.6 18.6 25.5 450° 75 225 325 232.2° 5.2 15.5 22.4-- 500, - 180 280 260.0°. - 12.4 19.3 550° - 130 230 287.8° - 9.0 15.9 Malleable Iron Threaded Fittings Pressure - Temperature Ratings Pressure Class 300 Temperature Class Sizes Sizes Sizes 150 '/4-1 1'/.°-2° 21/°-3° (6-25mm) (32-51 mm) (64-76mm) PSI/bar PSI/bar PSI/bar PSI/bar -20°-150° 300 2000 1500 1000 -28.9°-55.6° 20.7 137.9 103.4 68.9 200° 265 1785 1350 910 93.3° 18.3 123.1 93.1 62.7 250° 225 1575 1200 825 121.1° 15.5 108.6 82.7 56.9 300° 185 1360 1050 735 148.9° 12.8 93.8 72.4 50.7 350° 150 1150 900 650 176.7 10.3 79.3 62.1 44.8 400° - 935 750 560 204.4° 64.5 51.7 38.6 450° \ - 725 600 475 232.2° - 50.0 41.4 32.8 500° - 510 450 385 260,0° - 35.2 31.0 26.5 550° - 300 300 300 287.8° 20.7 20.7 20.7 ANVIL. An ASC Engineered Solution Note: Unions with Copper or Copper ALLoy seats are not intended for use where temperature exceeds 450°F. PROJECT INFORMATION APPROVAL STAMP Project: D Approved Address: fl Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1121-1122-1124-v0l 20220117 Ack Engineered Solutions Couplings & Cap (Class 150 Standard) Fig. 1121,1122,1124 Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME BI 6.3 ASTM A197 ASTM Al 53 ASME 81 20.1 ASME 816.3 Class 300/PN 50 ASME 1316.3 ASTM A197 ASTM A153 ASME Bl 20.1 ASME B163 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 1501PN 20 ASME 816.39 ASTM A197 ASTM A153 ASME BI 20.1 ASME 816.39 Class 250 ASME B16.39 ASTM A197 ASTM A153 ASME BI 20.1 ASME B16.39 Class 300/PN 50 ASME B16.39 ASTM A197 ASTM A153 ASME 81 20.1 ASME 1316.39 Note: ASTM B633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME 816 product standard asc-es.com Building connections that Last- PS-11.16 page 2 PS-SUB-1121-1122-1124-vOl 20220117 Unit Weight Size W Black Galvanized NPS/DN In/mm Lbs/kg Lbs/kg 1 /16 0.20 0.20 15 33 0.09 0.09 3/4 11/2 0.30 0.30 20 38 0,14 0.14 1 111/16 0.48 0.48 25 43 0.22 0.22 Unit Weight Size W Black Galvanized NPS/DN In/mm Lbs/kg Lbs/kg 11/4 115/16 0.75 0.75 32 49 0.34 0.34 11/2 21/8 1.00 1.00 40 54 0.45 0.45 2 21/2 1.45 1.45 50 64 0.66 0.66 Fig. 1122 Right & Left Coupling (Class 150 Standard) Fig. 1121 Coupling (Class 150 Standard) Unit Weight Size W Black Galvanized NPS/DN In/mm Lbs/kg Lbs/kg 15/16 0.06 0.06 6 24 0.03 0.03 1/4 11/16 0.09 0.09 8 27 0.04 0.04 1 /16 0.13 0.13 10 30 0.06 0.06 1/2 1/16 0.20 0.20 15 33 0.09 0.09 3/4 11/2 0.30 0.30 20 38 0.14 0.14 1 111/a 0.48 0.48 25 43 0.22 0.22 ~000 AI Engineered Soutions Unit Weight Size W Black Galvanized NPS/DNIn./mm Lbs/kg Lbs/kg 11/4 115/16 0.75 0.75 32 49 0.34 0.34 11/2 21/8 1.00 1.00 40 54 0.45 0.45 2 21/2 1.45 1.45 50 64 0.66 0.66 21/2 2/8 2.40 2.40 65 73 1.09 1,09 3 3/m 3.30 3.30 80 81 1.50 1,50 4 311/16 5.72 5.72 100 94 2.59 2.59 Note: *Offered in steel only. See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SolutionsrM Representative if you need verification. ALL Elbows & Tees 3/ (10 ON) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) F5 FO-1 0 asc-es.com Building connections that Last- PS-11.13 page 3 PS-SUB-1121-1122-1124-v0l 20220117 ASC Engineered Solutions Fig. 1124 Unit Weight Unit Weight Cap (Class 150 Standard) Size Size Black Galvanized Black Galvanized NPS/DN Lbs/kg Lbs/kg NPS/DN Lbs/kg 'Lbs/kg 1/2 0.12 0.12 21/2 1.75 1.75 15 0.05 0.05 65 0.79_- 0.79 - - 3/4 0.22 0.22 3 2.62 2.62 20 0.10 0.10 80 1.19 1.19 Ilk - 1 0.38 0.38 31/2 3.19 3.19 25 0.17 0.17 90 1.45 1.45 1¼ 0.58 0.58 4 4.54 4.54 32 0.26 0,26 100 2.06 2.06 11/2 0.73 0.73 5 6.45 6.45 40 0.33 0.33 125 2.93 * 2.93 - 2 1.13 1.13 6 10.00 10.00 50 0.51 0.51 150 4.54 4.54 Note: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SoLutionslm Representative if you need verification. ALL Elbows & Tees (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) UFO 0 asc-es.com Building connections that Last" P5-11.13 page 4 PS-SUB-1121-1122-1124-vol 20220117 4LFtiLItLo ASX~ Engineered Solutions Fig. 1121,1122,1124 Couplings & Cap (Class 150 Standard) General Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2 through 2' thread varies from 41/2 turns to 5 turns. For 21/2 through 4' sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2 through 4' thread varies from 51/2 turns to 6/4 turns. asc-es.com Building connections that Last- PS-11.13 page 5 PS-SUB-1121-1122-1124-vOl 20220117 Reducer (Class 150 Standard) Fig. 1125 c®us. USTED APPROVE 5A5c Engineered Solutions ASC Engineered Solutions"" offers the broadest line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASCs strict quality standards. All Anvil Class 150 Malleable Iron Fittings conform to ASME B16.3 and unions conform to ASME 816.39. ALL elbows and tees /8 (10 DN) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or Contact an ASC Engineered SotutionslM Representative. See following page for standards and specifications. Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings Pressure - Temperature Ratings Pressure - Temperature Ratings Pressure Pressure Class 300 Temperature Temperature Class Sizes Sizes Sizes Class 150 Class 250 Class 300 150 ".°-1 1¼-2 2'/-3 (6-25mm) (32.51 mm) (64-76mm) PSI/bar PSI/bar PSI/bar °F/°C PSI/bar PSI/bar PSI/bar PSI/bar -20°-150° 300 500 600 -20°-150° 300 2000 1500 1000 -28.9°-65.6° 20.7 34.5 41.4 -28.9°-65.6° 20.7 137.9 103.4 68.9 200° 265 455 550 200° 265 1785 1350 910 93.3° 18.3 31.4 37.9 93.3° 18.3 123.1 93.1 62.7 250° 225 405 505 250° 225 1575 1200 825 121.1° 15.5 27.9 34.8 121.1° 15.5 108.6 82.7 56.9 300° 185 360 460 300° 185 1360 1050 735 148.9° 12.8 24.8 31.7 148.9° 12.8 93.8 72.4 50.7 350° 150 315 415 350° 150 1150 900 650 176.7° 10.3 21.7 28.6 176.7° 10.3 79.3 62.1 44.8 400° 110 270 370 400° - 935 750 560 -204.4° 7.6 18,6 25.5 204.4° - 64.5 51.7 38.6 450° 75 225 325 450° - - 725 600 475 232.2° 5.2 15.5 22.4 232.2° 50.0 41.4 32.8 500° - 180 280 500° - - 510 450 385 260.0° - 12.4 19.3 260.0° 35.2 31.0 26.5 550° - 130 230 550° - 300 300 300 287.8° - 9.0 15.9 287.8° - 20.7 20.7 20.7 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F ANVIL. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: . flApproved Address: fl Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1125-vol 20211025 Mal I LiJitiigs Engineered Solutions Reducer (Class 150 Standard) Fig. 1125 Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 1316.3 ASTM A197 ASTM A153 ASME B1 20.1 ASME 1316.3 Class 300/PN 50 Malleable Iron Unions ASME B16.3 ASTM A197 ASTM A153 ASME BI 20.1 ASME B16.3 Dimensions Material Galvanizing* Thread Pressure Rating Clas15O/PN2O ASME 13116.39 ASTM A197 ASTM A153 ASME 13120.1 ASMEB1Ô.39 Class 250 Class 300/PN 50 ASME 1316.39 ASME 1316.39 ASTM A197 ASTM A197 ASTM A153 ASTM A153 ASME 13120.1 ASME 131 20.1 ASME 1316.39 ASME 1316.39 Note: ASTM B633. Type I, Sc 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard 0700 asc-es.com Building connections that Last- PS-11.16 page 2 PS-SUB-1125-vOl 20211025 UASC 40 Engineered Solutions Reducer (Class 150 Standard) Fig. 1125 Size M Unit Weight Black Galvanized NPS/DN NPS/DN In/mm Lbs/kg Lbs/kg 1/4 /8 1 0.07 0.07 8 6 25 0.03 0.03 1/8 0.11 0.11 6 0.05 0.05 11/8 10 1/ 29 0.11 on 8 0.05 0.05 1/8 0.14 0.14 6 0.06 0.06 1/2 1/4* 11/4 0.15 0.15 15 8 32 0.07 0.07 0.17 0.17 10 0.08 0.08 ¼ 0.24 0.24 6 0.11 0.11 1/4 0.22 0.22 3/ 8 1/15 0.10 0.10 20 37 3/ 0.25 0.25 10 0.11 0.11 0.27 0.27 15 0.12 0.12 1/4 . 0.35 0.35 8 0.16 0.16 1 1 11/16 25 43 /8 0.35 0.35 10 0.16 0.16 Notes Sizes ½ x 1/4,3/4 x 1/2 and lx 3/4 do not have bands at the reducing end. See first page for pressure-temperature ratings. GaLvanized weights may vary. Please contact yourASC Engineered SolutionslM Representative if you need verification. ALL Elbows & Tees 3/s (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) P5-06.13 page 3 Unit Weight Size M Black Galvanized - NPS/DN NPS/DN In/mm Lbs/kg Lbs/kg 1/2 0.39 0.39 1 15 1 11/16 0.18 21 - 25 3/4* 43 0.43 0.43 20 0.20 0.20 1/2 0.61 0.61 15 0.28 0.28 11/4 3/4 21/16 0.64 0.64 32 20 52 0.29 0.29 1 0.68 0.68 25 0.31 0.31 1/2 0.78 0.78 15 0.35 0.35 34 0.88 0.88 11/2 20 2/16 0.40 0.40 - 40 1 59 0.88 0.88 25 0.40 0.40 11/4 0.90 0.90 32 0.41 0.41 1/2 1.30 1.30 15 0.59 0.59 2 34 213/16 1.34 1.34 50 20 73 0.61 0.61 1 1.40 1.40 25 0.63 0.63 151 asc-es.com BuiLding connections that last' PS-SUB-1125-vOl 20211025 am 4 gAsc Engineered Sotutions Reducer (Class 150 Standard) Fig. 1125 (Continued) Unit Weight Size M Black Galvanized NPS/DN NPS/DN In/mm Lbs/kg Lbs/kg 11/4 1.53 1.53 2 32 213/16 0.69 0.69 50 11/2 73 1.55 1.55 40 0.70 0.70 1 2.12 2.12 25 0.96 0.96 11/4 2.09 2.09 21/2 32 31/4 0.95 0.95 65 11/2 83 2.09 2.09 40 0.95 0,95 2 2.51 2.51 50 1.14 1.14 1 3.16 3.16 25 1.43 1.43 11/4 2.99 2.99 32 1.36 1.36 3 1½ 311/16 3.30 3.30 80 40 94 1.50 1.50 2 3.25 3.25 50 1.47 1,47 21/2 3.31 3.31 65 1.50 1.50 Notes: Sizes ½ x 1/4,3/4 x ½ and lx 3/4 do not have bands at the reducing end. See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SotutionsiM Representative if you need verification. All Elbows & Tees /n' (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) PS-06.13 page 4 Unit Weight Size M Black Galvanized NPS/DN NPS/DN In/mm Lbs/kg Lbs/kg 31/2 90 2 50 21/2 65 3 80 4 102 4.32 1.96 4.72 2.14 4.99 2.26 4.32 1.96 4.72 2,14 4.99 2.26 11/2 4.90 4.90 40 2.22 2.22 2 5.10 5.10 50 2.31 2.31 4 21/2 4% 5.93 5.93 100 65 111 2.69 2.69 3 6.55 6.55 80 2,97 2.97 31/2 6.30 6.30 90 2.86 2.86 5 4 4/16 9.57 9.57 125 100 116 4.34 4.34 6 4 4 T1 10.30 10.30 150 100 124 4.67 4.67 asc-es.com Building connections that Last- PS-SUB-1125-vol 20211025 sc II Engineered Solutions Fig. 1125 Reducer (Class 150 Standard) General Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2' pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2" through 2" thread varies from 41/2 turns to 5 turns. For 21/2 through 4' sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2 through 4" thread varies from 51/2 turns to 6I4 turns. asc-es.com Building connections that Last- PS-11.13 page 5 PS-SUB-1125-01 20211025 ~~`JAM- Engineered Solutions Reducing Elbow (Class 150 Standard) Fig. 11O1R USTED APPRL - -- Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Pressure Temperature Class 150 Class 250 Class 300 PSI/bar PSI/bar PSI/bar -20°-150° 300 500 500 -28.9°--65.6' 20.7 34.5 41.4 200° 265 455 550 93.3° 18.3 31.4 37.9 250° 225 405 505 121.1 15.5 27.9 34.8 300° 185 360 460 148.9° 12.8 24.8 31.7 350° 150 315 415 176.7° 10.3 21.7 28.6 400° 110 270 370 204.4' 7.6 18.6 25.5 450° 75 225 325 232.2° 5.2 15.5 22.4 500° - 180 280 260.0° - 12.4 19.3 550° - 130 230 287.8° - 9.0 15.9 Malleable Iron Threaded Fittings Pressure - Temperature Ratings Pressure Class 300 Temperature Class Sizes Sizes Sizes 150 '/4-1 114-2° 21fa°-3° (6-25mm) (32-51 mm) (64-76mm) PSI/bar PSI/bar PSI/bar PSI/bar -20°--150° 300 2000 1500 1000 -28.9'--65.6' 20.7 137,9 103.4 68.9 200° 265 1785 1350 910 93.3' 18.3 123.1 93.1 62.7 250° 225 1575 1200 825 121.1' 15,5 108.6 82.7 56.9 300° 185 1360 1050 735 148.9' 12.8 93.8 72.4 50.7 350° 150 1150 900 650 76.7° 10.3 79.3 62.1 44.8 400° - 935 750 560 204.4' - 64.5 51.7 , 38.6 450° - 725 600 475 232.2' - 50.0 41.4 32.8 500° - 510 450 385 260.0' - 35.2 31.0 26.5 550° - 300 300 300 287.8' - 20.7 20.7 20.7 ASC Engineered SoLutionSTM offers the broadest tine of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASC's strict quality standards. All Anvil Class 150 Malleable Iron Fittings conform to ASME 816.3 and unions conform to ASME 816.39. ALL elbows and tees /8 (10 DN) and larger are 100% gas tested at minimum of 100 P51(6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered SoLutionsTm Representative. See following page for standards and specifications. Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. All elbows and tees 6'(1O DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). ANVIL. An ASC Engineered Solution Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F. PROJECT INFORMATION APPROVAL STAMP Project: fl Approved Address: 0 Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1101R-v01 20211118 1111 1111111111qJ11111 LA:nl- 1:fl,11111713 UIis A% Engineered Solutions Reducing Elbow (Class 150 Standard) Fig. 11O1R Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating - Class 150/PN 20 ASME 816.3 ASTM A197 ASTM A153 ASME B1 20.1 ASMEB13 Class 300/PN 50 ASME B16.3 ASTM A197 ASTM A153 ASME B1 20.1 ASME B16.3 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating -Class 150/PN 20 ASME 1316.39 ASTM A197 ASTM A153 ASME 13120.1 ASME B139 Class 250 Class 300/PN 50 ASME B16.39 ASME B16.39 ASTM A197 ASTM A197 ASTM A153 ASTM A153 ASME B1 20.1 ASME B1 20.1 ASME B1629 ASME B16.39 Note: ASTM B633. Type I, Sc 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard asc-es.com Building connections that Last- PS-11.16 page 2 PS-SUB-1101R-vol 20211118 WAviLMLII r1iFfigs Engineered SoWtions Reducing Elbow (Class 150 Standard) Fig. 11O1R Unit Weight Unit Weight Size X Z Size X Z Black Galvanized Black Galvanized NPS/DN NPS/DN In./mm In/mm Lbs/kg Lbs/kg NPS/DN NPS/DN In/mm In/mm Lbs/kg Lbs/kg 1/4 1/8 3/4 3/4 0.10 0.10 11/4 1 1 s/16 111/16 0.87 0.87 - 8 - 6 - 19 19 0.05 0.05 32 25 40 43 0.39 0.39 1/ 13/16 /8 0.12 0.12 3/4 11/2 1/4 0.83 0.83 3/ 6 22 - 22 0.05 0.05 20 38 44 0.38 0.38 10 1/4 /8 15/16 014 0,14 11/2 1 11/8 113/16 1,02 1.02 8 22 24 0.06 0.06 40 25 41 47 0.46 0.46 1/4 1 1 0.19 0.19 11/4 113/16 11/8 1.17 1.17 8 25 25 0.09 0.09 32 47 48 0.53 0.53 15 /e 1 V1 11/16 0.22 0.22 3/4 1/8 2 1.30 1.30 - - - 10 27 27 0.10 0.10 20 41 51 0.59 0.59 1/4 11/8 11/8 0.26 0.26 1 1/4 2 1.35 1.35 8 29 29 0.12 0.12 2 25 44 51 0,61 0.61 3/4 /8 11/8 11/8 0.29 0.29 50 11/4 11/8 21/8 1.53 1.53 20 , 10 29 29 0.13 0_13 32 48 54 0.69 0.69 1/2 1/16 11/4 0.38 0.38 11/2 2 21/8 1.75 1.75 15 30 - - 32 0.17 0.17 40 51 54 0.79 0.79 1/8 1/16 11/4 0.41 0.41 1 1/2 2/16 21/2 2.50 2.50 10 30 32 0.19 0.19 21/2 40 56 64 1.13 1.13 1 1/2 11/4 1% 0.46 0.46 65 2 2/16 2/a 2.98 2.98 25 15 32 35 0.21 0.21 50 62 67 1.35 1.35 3/4 1/a 1/16 0.56 0.56 2 2/16 215/16 3.75 3.75 20 35 37 0.25 0.25 3 50 65 75 1.70 1.70 1/2 1/8 1/16 0.61 0.61 80 21/2 213/16 3 4.30 4.30 11/4 15 35 40 0.28 0.28 65 73 76 1.95 1.95 32 3/4 17/16 1 /8 0.71 0.71 4 3 3/16 3/8 7.87 7.87 20 - 37 41 0.32 0.32 100 80 84 92 3.57 3.57 Notes: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SolutionsIm Representative if you need verification. All elbows and tees /a' (10 ON) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). MEO asc-es.com Building connections that Last- PS-0613 page 3 PS-SUB-1101R-v0l 20211118 LTLLqI am täLtIOfl 1 'Mc '~~P Engineered Solutions Fig. 1101R Reducing Elbow (Class 150 Standard) General. Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2 through 2" thread varies from 41/2 turns to 5 turns. For 21/2' through 4 sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2 through 4" thread varies from 51/2 turns to 6/4 turns. asc-es.com Building connections that last' P5-11.13 page 4 Ps-suB-1101R-vol 20211118 [b=le I =55 F-if-t6i -----JJJJJJJJJJ1V- 'ggl j M C Engineered Solutions Reducing Tee (Ct.ass 150 Standard) Fig. 1105R c®uS <3> LISTED APPROVEI Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings Pressure - Temperature Ratings Pressure - Temperature Ratings Pressure Pressure Class 300 Temperature Temperature Class Sizes Sizes Sizes Class 150 Class 250 Class 300 150 'i4-11- 11/-2 21Ia'-3' (6-25mm) (32-51 mm)(64-76mm) • PSI/bar PSI/bar PSI/bar °F/°C PSI/bar PSI/bar PSI/bar PSI/bar -20°-150° 300 500 600 -20°-150° 300 2000 1500 1000 -28.9°---65.6° 20.7 34.5 41.4 -28.9°-65.6° 20.7 137.9 103.4 68.9 200° 265 455 550 200° 265 1785 1350 910 93.3° 18.3 31.4 37.9 93.3° 18.3 123.1 93.1 62.7 250° 225 405 505 250° 225 1575 1200 825 121.1° 15.5 27.9 34.8 121.1° 15.5 108.6 82.7 56.9 300° 185 360 460 300° 185 1360 1050 735 148.9° 12.8 24.8 31.7 148.9° 12.8 93.8 72.4 50.7 350° 150 315 415 350° 150 1150 900 650 176.7° 10.3 21.7 28.6 176.7° 10.3 79.3 62.1 44.8 400° 110 270 370 400° - - 935 750 560 204.4° 7,6 18.6 25.5 204.4° 64.5 51.7 38.6 450° 75 225 325 450° - 725 600 475 232.2° 5.2 15.5 22.4 232.2° - 50.0 41.4 32.8 500° - 180 280 500° - 510 450 385 2600° - 12.4 19.3 260.0° - - 35.2 31.0 26.5 550° - 130 230 550° 300 300 300 287.8° - 9.0 15.9 287.8° - 20.7 20.7 20.7 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F. ASC Engineered SolutionsTM offers the broadest line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASC's strict quality standards. All Anvil Class 150 MalleabLe Iron Fittings conform to ASME B16.3 and unions conform to ASME B16.39. All elbows and tees W (10 DN) and larger are 100% gas tested at minimum of 100 P51(6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered Solutions Representative. See following page for standards and specifications. fp ANVIL. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: fl Approved Address: El Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1105R-vOl 20220104 jFL MAnxtJ [~", "T, =Mafflea"ti,11011 ASC. Engineered Solutions it Reducing Tee (C[ass 150 Standard) Fig. 1105R Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME BI 6.3 ASTM A197 ASTM Al 53 ASME Bl 20.1 ASME B16.3 - - Class 300/PN 50 ASME B16.3 ASTM Al 97 ASTM Al 53 ASME BI 20.1 ASME B16.3 - Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME Bl 6.39 ASTM A197 ASTM Al 53 ASME BI 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A197 ASTM A153 ASME Bl 20.1 ASME 8139 Class 300/PN 50 ASMEB16.39 ASTM A197 ASTM A153 ASME B1 20.1 ASME B1Ô.39 Note: ASTM B633. Type I, Sc 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard HMO 0 asc-es.com Building connections that Last- P5-11.16 page 2 PS-SUB-1105R-vOl 20220104 JMJ1inFiW1Ogs ASC Engineered Solutions Reducing Tee (CLass 150 Standard) Fig. 1105R Unit Weight Unit Weight Size X V Z Size X V Z - - - - Black Galv. Black Galv. NPS/DN NPS/DN NPS/DN In/mm In/mm In/mm Lbs/kg Lbs/kg NPS/DN NPS/DN NPS/DN In./mm In/mm In/mm Lbs/kg Lbs/kg 1/8 1/8 1/4 3/4 3/4 3/4 0.12 0.12 1/4 3/4 1 /16 1 1/8 1 /16 0.45 0.45 5 6 8 19 19 19 0.05 0.05 8 20 33 29 33 0.20 0.20 1/8 3/4 3/4 3/4 0.13 0.13 3/ 11/8 /o 11/8 0.36 - 1/4 1/4 6 19 19 19 0.06 0.06 /8 10 29 24 29 0.16 - 8 8 3/ 15/ 15/16 7/ 0.19 0.19 10 3/4 1 /16 11/8 1 /16 0.46 0.46 10 24 24 22 0.09 0.09 20 33 29 33 0.21 0.21 1/4 /8 13/16 15/16 0.19 0.19 1/2 1 /16 1 1/8 11/4 0.43 0.43 1/4 8 22 -- 22 24 0.09 0.09 1/2 15 30 29 32 0.20 0.20 8 /8 15/16 15/16 15/16 0.21 0.21 15 3/4 1-,/16 11/4 1 /16 0.51 0.51 10 24 24 24 0.10 0.10 3/4 20 33 32 33 0.23 0.23 - 10 1/4 7/ /8 15/16 0.21 0.21 20 1/4 1 1/16 1 1/16 11/8 0.38 0.38 %- 8 - 22 22 24 0.10 0.10 8 27 27 29 0.17 0.17 10 1/2 1 1/16 1 1/16 11/16 0.27 0.27 /8 11/8 11/5 1 1/8 0.42 0.42 15 27 27 27 0.12 0.12 10 29 29 29 0.19 0.19 1/4 1/2 11/8 15/16 1 1/8 0.29 0.29 3/4 1/2 1 /16 1 /16 11/4 0.47 0.47 8 15 29 24 29 0.13 0.13 20 15 22 30 32 0.21 0.21 /8 1 1/16 1 11/16 0.28 0.28 1 1/16 1/16 1/8 0.62 0.62 /8 10 27 25 27 0.13 0.13 25 37 37 35 0.28 0.28 10 1/2 11/8 1 1/16 11/8 0.33 0.33 11/4 1 /8 1 /8 17/16 0.90 0.90 15 29 27 29 0.15 0.15 32 41 41 37 0.41 - 0.41 1/2 1/4 1 1 1 0.27 0.27 1/4 1 1/2 1/16 1 1/2 0.69 0.69 15 8 25 25 25 0.12 0.12 8 25 38 33 38 0.31 0.31 3/ 1 1/16 1 1/16 11/16 0.30 0.3 1/2 11/4 11/8 1 /8 0.70 0.70 1/2 0 27 27 27 0.14 0.14 1 15 32 29 35 0.32 0.32 15 3/4 11/4 11/4 1 /16 0.45 0.45 25 1/2 3/4 1/8 11/4 17/16 0.56 0.56 20 32 32 30 0.20 0.20 15 20 35 32 37 0.25 0.25 1 1/s 1/a 11/4 0.55 0.55 1 11/2 1/a 1 1/2 0.76 0.76 -.25 3535320.250.25 253835380.340.34 Notes: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered Solutionsm Representative if you need verification. All elbows and tees 3/ (10 DN) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). See additionaL sizes on following page. ILWI L1 asc-es.com Building connections that Last- PS-0613 page 3 PS-SUB-1105R-v0l 20220104 Size X V NPS/DN NPS/DN NPS/DN In/mm In/mm 3/4 11/4 1 3/4 11/8 20 32 44 41 1/2 1 /8 11/4 15 35 32 3/4 17/16 1 /8 1 20 37 35 25 1 1/16 11/2 25 40 38 1 1/4 1 3/4 111/16 32 44 43 11/4 /8 11/4 11/4 32 10 32 32 1/3 1 /8 1 /8 15 35 35 3/4 17/16 17/16 11/4 20 37 37 32 1 19/16 1/16 25 40 40 11/2 1/8 1/8 40 48 48 2 21/8 21/8 50 54 54 1/2 11/2 115/16 1 11/16 15 40 49 43 11/2 3/4 11/2 1 /16 40 3/4 20 38 33 20 11/2 115/16 13/4 40 49 44 Unit Weight Black Galv. In/mm Lbs/kg . Lbs/kg 1/4 1.04 1.04 44 0.47 0.47 1/16 0.76 0.76 40 0.34 0.34 11/8 0.87 0.87 41 0.39 0.39 111/16 1.11 1.11 43 0.50 0.50 1/4 1.13 ' 1.13 44 0.51 0,51 1/16 0.86 0.86 37 0.39 -0.39 1 /io 0.98 0.98 40 0.44 --0.44-- 11/8 1.07 1.07 41 0.49 0.49 111/16 1.18 , 1.18 43 0.54 0.54 1/i6 1.45 1.45 47 0.66 0.66 1/8 1.70 1.70 48 0.77 0.77 115/16 1.33 1.33 49 0.60 0.60 1/4 1.00 1.00 44 0.45, 0.45 115/16 1.41 1.41 49 0.64 0.64 i Fi_i FTffngw!!l1 AP &SC a Engineered Solutions Reducing Tee (Class 150 Standard) Fig. 1105R (Continued) II Unit Weight Size X Y Z Black Galv. NPS/DN NPS/DN NPS/DN In/mm In/mm In/mm Lbs/kg Lbs/kg 1/2 11/4 1 /16 1 /8 0.59 0.59 15 32 30 35 0.27 0,27 3/4 3/4 1 /8 1 /16 17/16 0.74 0.74 20 20 35 33 37 0.34 0.34 1 1'/2 1/16 11/2 0.78 0.78 25 38 37 38 0.35 0.35 1/4 11/8 11/8 11/4 0.53 0.53 8 29 29 44 0.24 0.24 3/ 1/16 1/16 11/4 0.60 0.60 10 30 30 32 0.27 0.27 25 1/2 11/4 11/4 1 /8 0.70 0.70 15 32 32 35 0.32 0.32 1 3/4 1 /8 1 /8 17/16 0.82 0.82 25 20 35 35 37 0.37 0.37 11/4 111/16 111/16 1/16 0.92 0.92 32 43 43 40 0.42 0.42 11/2 113/16 113/16 15/8 1.19 1.19 40 47 46 41 0.54 0.54 2 2 2 1/4 1.63 1.63 50 51 51 44 0.74 0.74 1 1/16 1/8 111/16 0.87 0.87 1/3 25 40 35 43 0.39 0.39 15 11/4 13/4 1 /15 1/4 1.04 1.04 11/4 32 - 44 40 44 0.47 0,47 32 3/4 1/16 1/16 1/8 0.86 0.86 3/4 20 37 33 41 0.39 0.39 20 1 1/16 1/16 111/16 0.91 0.91 25 40 37 43 0.41 0.41 Notes: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered Sotutions Representative if you need verification. All elbows and tees /8"(10 ON) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). See additional sizes on previous and foLLowing page. asc-es.com Building connections that last' PS-06.13 page 4 PS-SUB-1105R-vol 20220104 Engineered Solutions Reducing Tee (CLass 150 Standard) Fig. 1105R (Continued) NPS/DN Size NPS/DN NPS/DN X In/mm V In/mm Z In/mm Unit Weight Black Galv. Lbs/kg Lbs/kg 1 1/8 11/2 113/16 1.14 1.14 25 41 38 47 0.52 0.52 1 11/4 113/16 111/16 17/8 1.30 1.30 25 32 47 43 48 0.59 0.59 11/2 1 15/16 1 /16 Vs/16 1.50 1.50 40 - 49 47 49 0.68 0.68 1/2 1 /16 1 % 111/16 1.05 1.05 15 37 35 43 0.48 0,48 3/4 11/2 1/16 1/4 1.08 1.08 20 38 37 44 0.49 0,49 11/4 1 11/8 1 /16 113/16 1.26 1.26 32 25 41 40 47 0.57 0.57 11/3 11/4 113/16 1/4 11/8 1.52 1.52 40 32 47 44 48 0.69 0.69 11/3 115/16 1 /8 115/16 1.50 1.50 40 49 48 49 0.68 0.68 1/2 17/16 17/16 111/16 1.19 1.19 15 37 37 43 0.54 0.54 3/4 11/2 11/2 1 3/4 1.60 1.60 20 38 38 44 0.73 0.73 11/2 1 1 5/5 1 5/ 113/16 1.45 1.45 40 25 41 41 47 0.66 0.66 11/4 1 /16 113/16 17/8 1.45 1.45 32 47 47 48 0.66 0.66 2 2/16 2/16 2 1.86 1.86 50 56 56 51 0.84 0.84 Unit Weight Size X V Z Black Galv. NPS/DN NPS/DN NPS/DN In/mm In/mm In/mm Lbs/kg Lbs/kg 3/4 2 21/4 115/16 21/4 2.00 2.00 20 50 57 49 57 0.91 091 1 2 21/4 2 21/4 2.14 2.14 25 50 57 51 57 0.97 0.97 11/4 11/8 1/4 21/8 1.72 1.72 32 48 44 54 0.78 0.78 11/4 11/2 2 1/8 2/16 1.85 1.85 32 40 51 48 56 0.84 0.84 2 21/4 21/8 21/4 2.20 2.20 50 57 54 57 1.00 1.00 1 1/4 1/8 2 1.57 1.57 25 44 41 51 0.71 0.71 1 1/4 17/8 1"/16 21/8 1.76 1.76 2 11/2 32 48 47 54 0.80 0.80 50 40 11/2 2 115/16 2/16 1.95 1.95 40 - 51 49 56 0.88 0.88 2 21/4 2/16 21/4 2.24 2.24 50 57 56 57 1.02 1.02 1/2 11/2 11/2 17/8 1.65 1.65 15 38 38 48 0.75 0.75 3/4 1 /8 1 /8 2 1.87 1.87 20 41 41 51 0.85 0.85 2 1 1/4 1/4 2 1.76 1.76 50 25 44 44 51 0.80 0.80 11/4 1 7/ 17/8 21/8 2.35 2.35 32 48 48 54 1.07 1.07 2 1/2 2 21/4 1/8 21/4 2.15 2.15 11/2 2 2 2/16 2.55 2.55 50 15 50 57 48 57 0.98 0.98 40 51 51 56 1.16 116 Notes: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered Sotutionslm Representative if you need verification. ALL elbows and tees 3/ (10 DN) and larger are 100% gas tested at a minimum of 100 P51(6.9 bar). See additional sizes on previous and following page. IJ J asc-es.com Building connections that Last- PS-0613 page 5 PS-SUB-1105R-vol 20220104 8uMRIfiaLLeaoJeII IkO Diii U A Engineered Solutions Reducing Tee (Class 150 Standard) Fig. 1105R (Continued) Size X V Z Unit Weight Black Galv. NPS/DN NPS/DN NPS/DN In/mm In/mmIn./mm Lbs/kg Lbs/kg 2 2 21/2 2/8 2/a 2/e 3.50 3.50 50 50 65 67 67 60 1.59 1.59 2 2/8 2/16 2/8 3.43 3.43 1½ 50 60 56 67 1.56 1.56 40 21/2 211/16 21/2 211/16 3.80 3.80 65 68 64 68 1.72 1.72 2 2/8 21/4 2/n 3.28 3.28 2 50 60 57 67 1.49 1.49 50 21/2 211/16 2/8 211/16 4.10 4.10 65 68 67 68 1.86 1.86 3/4 1/4 1/4 2/16 2.72 2.72 21/2 20 44 44 59 1.23 1.23 65 1 1/8 1/8 2/8 2.85 2.85 25 48 48 60 1.29 1.29 11/4 21/16 21/16 2/16 3.36 3.36 21/2 32 52 52 62 152 1.52 65 11/2 2/16 2/16 21/2 3.46 3.46 40 56 56 64 1.57 1.57 2 2/n 2/s 2/n 3.65 3.65 50 60 60 67 1.66 1.66 3 3 3 213/16 5.82 5.82 80 76 76 73 2.64 2.64 2 21/2 21/4 2/8 4.50 4.50 3 2 50 64 57 73 2.04 2.04 80 50 3 31/8 2/8 31/8 5.80 5.80 80 79 73 79 2.63 2.63 Unit Weight Size X V Z Black Galv. NPS/DN NPS/DN NPS/DN In/mm In/mm In/mm Lbs/kg Lbs/kg 2 21/2 2/s 2/8 4.80 4.80 21/2 50 64 60 73 2.18 2.18 65 21/2 213/16 211/16 3 5.80 5.80 65 73 68 76 2.63 2.63 3/4 1/8 1/8 2/8 4.03 4.03 20 48 48 67 1.83 1:83 1 2 2 2/8 4.13 . 4.13 3 25 51 51 67 187_ 1.87 80 1 1/4 2/16 2/16 2/4 4.50 4.50 3 32 56 56 70 2.04 204 80 1 1/2 2/16 2/16 213/16 5.18 5.18 40 59 59 73 2.35 2.35 2 21/2 21/2 2/8 5.70 5.70 50 64 64 73 2.59 259 21/2 2/16 2°/16 3 6.09 6.09 65 73 73 76 2.76 . 2.76 3 4 3/m 35/s 313/16 10.40 10.40 80 100 98 92 98 4.72 472 11/2 21/2 21/2 3/8 7.47 7.47 40 65 65 86 - 3.39 3.39-- 4 2 2'/4 2/4 3/16 8.39 8.39 100 4 50 70 70 87 30 3.80 100 21/2 31/16 31/16 31/2 9.60 9.60 65 78 78 89 435 3 3/ 3/1. 3/8 11.02 11.02 80 84 84 92 5.00 5.00 Notes: See first page for pressure-temperature ratings. GaLvanized weights may vary. Please contact your ASC Engineered SoLutions Representative if you need verification. All elbows and tees i/a" (10 ON) and Larger are 100% gas tested at a minimum of 100 P51(6.9 bar). See additional sizes on previous page. asc-es.com Building connections that Last- PS-0613 page 6 PS-SUB-1105R-v0l 20220104 @ ~ ")~ A.W. - Engineered Solutions Fig. 1105R Reducing Tee (Class 150 Standard) GeneraL Assembly of Threaded Fittings 1 Inspect both male and femaLe components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2" through 2" thread varies from 41/2 turns to 5 turns. For 21/2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2 through 4" thread varies from 51/2 turns to 61/4 turns. LIJA asc-es.com Building connections that Last - PS-11.13 page 7 Ps-suB-1105R-41 20220104 Elbow & Tee (Class 150 Standard) LI Fig. 1104 450 Street Elbo Li Fig. 1105 Straight Tee Fig. 1104 c®uS <8> LISTED APPROVED Fig. 1105 Malleable Iron Threaded Pipe Unions Malleable Iron Threaded Fittings Pressure - Temperature Ratings Pressure -Temperature Ratings Engineered Solutions ASC. Engineered So1utionsTM offers the broadest Line of malleable iron fitting sizes in both black and gaLvanized finishes. Every fitting is manufactured and tested to meet ASC's strict quality standards. ALL Anvil Class 150 Malleable Iron Fittings conform to ASME B16.3 and unions conform to ASME B16.39. All elbows and tees /" (10 DN) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or Contact an ASC Engineered Solutions Representative. See following page for standards and specifications. Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME 816.39. All elbows and tees W (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). Temperature Pressure Class 150 Class 250 Class 300 PSI/bar PSI/bar PSI/bar Pressure Class 300 Temperature Class Sizes Sizes Sizes 150 '/°-1° 11/4'-2- 2/a3° (6-25mm) (32-51 mm) (64-76mm) °FI°C PSI/bar PSI/bar PSI/bar PSI/bar -20°150° 300 500 600 -20°-150° 300 2000 1500 1000 -28.9°-65.6° 20.7 34.5 41.4 -28.9°-65.6° 20.7 137.9 103.4 68.9 200° 265 455 550 200° 265 1785 1350 910 -93.3° 18.3 31.4 37.9 93.3° 183 123.1 93.1 62.7 250° 225 405 505 250° 225 1575 1200 825 121.1° 15.5 27.9 34.8 121 1° 15.5 108.6 82.7 56.9 300° 185 360 460 300° 185 1360 1050 735 148.9° 12.8 24.8 31.7 148.9° 128 93.8 72.4 50.7 350° 150 315 415 350° 150 1150 900 650 176.7° 10.3 21.7 28.6 175.7° 10.3 79.3 62.1 44.8 400° 110 270 370 400° - 935 750 560 204.4° 7.6 18.6 25.5 204.4° - 54.5 51.7 38 450° 75 225 325 450° - 725 600 475 232.2° 5.2 15.5 22.4 232.2° - 50.0 41.4 32.8 500° - 180 , 280 500° - 510 450 385 260.0° - 12.4 19.3 260.0° - 35.2 31.0 26.5 550° - 130 230 550° - 300 300 300 287.8° - 9.0 15.9 287.8° - 20.7 20.7 20.7 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F. ANVIL. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: fl Approved Address: []Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Ps-11.16 page 1 PS-SUB--1104-1105-vOl 20211118 4 AM ' Engineered Solutions Elbow & Tee (Class 150 Standard) Fig. 1104,1105 Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 816.3 ASTM Al 97 ASTM Al 53 ASME 131 20.1 ASME BI 6.3 Class 300/PN 50 ASME 816.3 ASTM A197 ASTM A153 ASME 81 20.1 ASME B16.3 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 15O/PN20 - ASME 816.39 ASTM A197 ASTM A1S3 ASME B1 20.1 ASMEB16.39 -- Class 250 - ASME 816.39 ASTM A197 ASTM A153 ASME 13120.1 ASME B16.39 - Class 3001PN 50 ASME 816.39 ASTM A197 ASTM Al 53 ASME BI 20.1 ASME B16.39 Note: ASTM B633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME 816 product standard asc-es.com Building connections that Last- PS-11.16 page 2 PS-SUB-1104-1105-vOl 20211118 -AH 1/8 6 1/4 8 10 1/2 15 3/4 20 25 1 1/4 32 1 1/2 40 2 50 21/2 65 3 80 31/2 90 4 100 5 125 6 150 11/16 17 13/io 22 15/16 24 11/8 29 1 /16 33 11/2 38 1 3/4 44 115/is 49 21/4 57 2 11/16 68 3 1/16 78 3 /o 87 313/16 98 41/2 114 51/8 130 _ iLIiffiWs AC Engineered Solutions Fig. 1104 Fig. 1105 450 Street Elbow (Class 150 Standard) Straight Tee (Class 150 Standard) Unit Weight Size C K Size A Black Galvanized NPS/DN In/mm In/mm - Lbs/kg Lbs/kg NPS/DN In/mm 1/8 11/16 /8 0.06 0.06 6 17 22 0.03 0.03 1/4 3/4 15/16 0.10 0.10 8 19 24 0.05 0.05 /16 1 0.14 0.14 10 22 25 0.06 0.06 1/2 /8 1 1/8 0.20 0.20 15 22 29 0.09 - 0.09 'A 1 1/16 0.33 0.33 20 25 33 0.15 0.15 1 11/8 1/16 0.52 0.52 25 29 37 0.24 0.24 11/4 1 /16 1 11/16 0.85 0.85 32 33 43 0.39 0.39 1 1/2 17/16 11/8 1.22 1.22 40 37 48 0.55 0.55 2 111/16 21/4 1.92 1.92 50 43 57 0.87 0.87 Notes: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SoLutions Representative if you need verification. All elbows and tees /e' (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). Unit Weight Black Galvanized Lbs/kg Lbs/kg 0.09 0.09 0.04 0.04 0.15 0.15 0.07 .0.07 0.23 0.23 0.10 0.10 0.41 0.41 0.19 0.19 0.60 0.60 0.27 0.27 0.90 0.90 0.41 0.41 1.31 '1.31 0.59 0.59 1.73 1.73 0.78 0,78 2.52 2.52 1.14 1.14 4.90 4.90 2.22 2.22 7.13 7.13 3.23 '323 9.00 9.00 4.08 . 4.08 11.32 11.32 5.13 5.13 19.42 19.42 8.81 . 8.81 25.50 25.50 11.56 11.56 EUJ asc-es.com Building connections that Last' PS-11.13 page 3 PS-SUB-1104-1105-v0l 20211118 MiLtI rMFi jul IIIs11'fIbiii ~~'j MC. Engineered Solutions Fig. 1104,1105 Mow & Tee (Class 150 Standard) General. Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughty mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for ½" through 2" thread varies from 41/2 turns to 5 turns. For 21/2" through 4 sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4" thread varies fron 51/2 turns to 6/4 turns. RIO 0_1 asc-es.com Building connections that Last- PS-11.13 page 4 PS-SUS-1104-1105-v0l 20211118 Engineered Solutions 900 Elbow (Class 150 Standard) Fig. 1101 USTED APPR ASC Engineered Solutions- offers the broadest line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and tested to meet ASC's strict quality standards. ALL Anvil CLass 150 Malleable Iron Fittings conform to ASME B16.3 and unions conform to ASME B16.39. All elbows and tees /8 (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered SoLutionslM Representative. See following page for standards and specifications. Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME 816.39. All elbows and tees 3/s's (10 DN) and larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). Malleable Iron Threaded Pipe Unions Pressure Temperature Ratings Pressure Temperature Class 150 Class 250 Class 300 PSI/bar PSI/bar PSI/bar -20°-150° 300 500 600 -28.9°-65.6° 20.7 34.5 41.4 200° 265 455 550 9330 18.3 31.4 37.9 2500 225 405 505 121.10 15.5 27.9 34.8 3000 185 360 460 148.90 12.8 24.8 31.7 3500 150 315 415 176.70 10.3 21.7 28.6 4000 110 270 370 204.40 7.6 18.6 25.5 4500 75 225 325 232.20 5.2 15.5 22.4 5000 - 180 280 260.00 - 12.4 19.3 5500 - 130 230 287.80 - 9.0 15.9 Malleable Iron Threaded Fittings Pressure -Temperature Ratings Pressure Class 300 Temperature Class Sizes Sizes Sizes 150 14°1° 11/4"-2" 21/2"-3" (6-25mm) (32-51 mm)(64-76mm) 0F/0C PSI/bar PSI/bar PSI/bar PSI/bar -20°-150° 300 2000 1500 1000 -28,9°-65.6° 207 137.9 103.4 68.9 2000 265 1785 1350 910 933° 18.3 123.1 93.1 627 2500 225 1575 1200 825 121.10 15.5 108.6 82.7 56.9 300° 185 1360 1050 735 148.9° 12.8 93.8 72.4 50.7 350° 150 1150 900 650 176.7° 10.3 79,3 62.1 44.8 400° - 935 750 560 204.4° - 64.5 51.7 38.6 450° - 725 600 475 232.2° - 50.0 41.4 32.8 500° - 510 450 385 260.0° 35.2 31.0 26.5 550° - 300 300 300 287.8° - 20.7 20.7 20.7 ANVIL. An ASC Engineered SoLution Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F. PROJECT INFORMATION APPROVAL STAMP Project: fl Approved Address: Approved as noted Contractor: El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1101-v0l 20211110 6;11mc. Engineered Soutions 900 Elbow (Class 150 Standard) Fig. 1101 Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 316.3 ASTM A197 ASTM Al 53 ASME 31 20.1 ASME Bl 6.3 Class300/PN 50 ASME 316.3 ASTM A197 ASTM A153 ASME BI 20.1 ASME B16.3 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 316.39 ASTM Al 97 ASTM Al 53 ASME BI 20.1 ASME BI 6.39 Class 250 ASME 316.39 ASTM A197 ASTM A153 ASME BI 20.1 ASME B16.39 Class 300/PN 50 ASME 316.39 ASTM A197 ASTM A153 ASME 131120.1 ASME B16.39 Note: ASTM B633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard. IE asc-es.com BuiLding connections that Last- PS-1116 page 2 PS-SUB-1101-vOl 20211110 Black Unit Weight Galvanized Lbs/kg Lbs/kg 1.30 1.30 0.59 0,59 2.06 2.06 0.93 , 0.93 3.55 3.55 1.61 1,61 5.46 5.46 2.48 2.48 7.10 7.10 3.22 3.22 8.95 8.95 4.06 4.06 13.90 13.90 6.30 6.30 23.00 23.00 10.43 10.43 Size N P S/D N 11/2 40 2 50 21/2 65 3 80 31/2 90 4 100 5 125 6 150 A In/mm "/16 49 21/4 57 211/16 68 31/16 78 3/16 87 313/16 98 41/2 114 51/8 130 Mn V. .;vWila"fflat Me! I S Engineered Sokitions 900 Elbow (Class 150 Standard) Fig. 1101 Unit Weight Size A Black Galvanized NPS/DN In/mm Lbs/kg Lbs/kg 1/8 0.06 0.06 6 17 0.03 0.03 1/4 13/16 0.11 0.11 8 22 0.05 0.05 15/16 0.17 0.17 10 24 0.08 0.08 1/2 11/8 0.30 0.30 15 29 0.14 0.14 3/4 1/16 0.45 0.45 20 33 0.20 0.20 1 11/2 0.73 0.73 25 38 0.33 0,33 11/4 1/4 0.97 0.97 32 44 0.44 0,44 Note: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SolutionsnM Representative if you need verification. All elbows and tees /a (10 ON) and Larger are 100% gas tested at a minimum of 100 P51(6.9 bar). RE no 0 asc-es.com Building connections that Last- PS-0613 page 3 PS-SUB-1101-v0l 20211110 1 ~~AK- 65& Engineered Solutions Fig. 1101 900 Elbow (Class 150 Standard) General. Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2' pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2" through 2" thread varies from 41/2 turns to 5 turns. For 21/2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4" thread varies from 51/2 turns to 6/4 turns. asc-es.com Building connections that Last- PS-11.13 page 4 PS-SUB-1101-01 20211110 Fig. 1121 Fig. 1124 cVL us <> LISTED APPROVED Malleable Iron Threaded Pipe Unions Pressure -Temperature Ratings Malleable Iron Threaded Fittings Pressure - Temperature Ratings Couplings & Cap (Class 150 Standard) El Fig. 1121 Right Hand Coupling E Fig. 1122 Right & Left Coupling El Fig. 1124 cap Engineered Solutions ASC Engineered SolutionsTM offers the broadest Line of malleable iron fitting sizes in both black and galvanized finishes. Every fitting is manufactured and rested to meet ASCs strict quality standards. AlLAnvil Class 150 Malleable Iron Fittings conform to ASME 1316.3 and unions conform to ASME 1316.39. Alt elbows and tees W (10 DN) and Larger are 100% gas tested at a minimum of 100 PSI (6.9 bar). For Listings/Approval Details and Limitations, visit our website at www.asc-es.com or contact an ASC Engineered SoLutionsTM Representative. See following page for standards and specifications. Pressure Temperature Class 150 Class 250 Class 300 0F/0C PSI/bar PSI/bar PSI/bar 200_1500 300 500 600 28.9065.60 20.7 34.5 41.4 2000 265 455 550 9330 18.3 31.4 37.9 2500 225 405 505 121.10 15.5 27.9 34.8 3000 185 360 460 148.90 12.8 24.8 31.7 3500 150 315 415 176.70 10.3 21.7 28.6 4000 110 270 370 204.40 7.5 18.6 25.5 450' 75 225 325 232.20 5.2 15.5 22.4 5000 - 180 280 260.00 - 12.4 19.3 5500 - 130 230 287.80 - 9.0 15.9 Pressure Class 300 Temperature Class Sizes Sizes Sizes 150 '/.'1' 1'4'-2' 21/2'-3' (6-25mm) (32-51 mm) (64-76mm) PSI/bar PSI/bar PSI/bar PSI/bar -20'150' 300 2000 1500 1000 -28.9'-65.6° 20.7 137.9 103.4 58.9 2000 265 1785 1350 910 9330 18.3 123.1 93,1 62.7 2500 225 1575 1200 825 121.10 15.5 108.5 82.7 56.9 3000 185 1360 1050 735 148.90 12.8 93.8 72.4 50.7 3500 150 1150 900 650 176.70 10.3 79.3 52.1 44.8 4000 - 935 750 560 204.40 - 64.5 51.7 38.6 450' - 725 600 475 232.20 - 500 41.4 32.8 5000 - 510 450 385 260.00 - 35.2 31.0 26,5 5500 - 300 300 300 287.80 20.7 20.7 20.7 ANVIL. An ASC Engineered Solution Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450'F. PROJECT INFORMATION APPROVAL STAMP Project: fl Approved Address: D Approved as noted Contractor: D Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: P5-11.16 page 1 PS-SUB-1121--1122-1124--vOl 20220117 1100 r1aoiF1iJiJgs. Engineered Solutions Couplings & Cap (Class 150 Standard) Fig. 1121,1122,1124 Standards and Specifications Malleable Iron Fittings Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 1316.3 ASTM A197 ASTM A153 ASME 8120.1 ASME B16.3 Class 300/PN 50 ASME B16.3 ASTM A19] ASTM A153 ASME B1 20.1 ASME B16.3 Malleable Iron Unions Dimensions Material Galvanizing* Thread Pressure Rating Class 150/PN 20 ASME 816.39 Class 250 ASMEB16.39 ASTM A197 ASTM A197 ASTM A153 ASTM A153 ASME 8120.1 ASME BI 20.1 ASME 816.39 ASMEB16.39 Class 300/PN 50 ASME 816.39 ASTM A197 ASTM A153 ASME 81 20.1 ASME B16.39 Note: ASTM B633. Type I, Sc 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard. IL asc-es.com Building connections that Last- PS-11.16 page 2 PS-SUB-1121-1122-1124-vOl 20220117 SC ,~~';~o ! Engineered Solutions Fig. 1121 Unit Weight Unit Weight Coupling (CLass 150 Standard) Size W Size W Black Galvanized Black Galvanized NPS/DN In/mm Lbs./kg Lbs/kg NPS/DN In/mm Lbs/kg Lbs/kg 1/8* 15/16 0.06 0.06 11/4 115/16 0.75 0.75 I 6 24 0.03 0.03 32 49 0,34 0.34 W k- 1/ 11/16 0.09 0.09 11/2 21/8 1.00 1.00 8 27 0.04 0.04 40 54 0.45 0.45 1/16 0.13 0.13 2 21/2 1.45 1.45 10 30 0.06 0.06 50 64 0.66 0.66 1/2 1/16 0.20 0.20 21/2 2/8 2.40 2.40 15 33 0.09 0.09 65 73 1.09 1.09 3/4 11/2 0.30 0.30 3 3/16 3.30 3.30 20 38 0.14 0.14 80 81 1.50 1.50 1 111/16 0.48 0.48 4 311/16 5.72 5.72 25 43 0.22 0.22 100 94 2,59 2.59 Fig. 1122 Unit Weight Unit Weight Right & Left Coupling Size W Size W (Class 150 Standard) Black Galvanized Black Galvanized NPS/DN In/mm Lbs/kg Lbs/kg NPS/DN In/mm Lbs/kg Lbs/kg 1/2 1 /16 0.20 0.20 11/4 115/16 0.75 0.75 r 15 33 0.09 0,09 32 49 0.34 0.34 W 3/4 11/2 0.30 0.30 11/2 21/8 1.00 1.00 I , 20 38 0.14 0.14 40 54 0,450.45 1 111/16 0.48 0.48 2 21/2 1.45 1.45 25 43 0.22 0.22 50 64 0.66 0.66 Note: *Offered in steel only. See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SotutionsrM Representative if you need verification. All Elbows & Tees /a (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) asc-es.com Building connections that Last- I 4 PS-11.13 page 3 PS-SUB-1121-1122-1124-v0l 20220117 Ack - Engineered Solutions Fig. 1124 Cap (Class 150 Standard) Unit Weight Unit Weight Size Size Black Galvanized Black Galvanized NPS/DN Lbs/kg Lbs/kg 1/2 0.12 0.12 15 0.05 0.05 3/4 0.22 0.22 20 0.10 0.10 1 0.38 0.38 25 0.17 0.17 11/4 0.58 0.58 32 0.26 0.26 11/2 0.73 0.73 40 - 0.33 0.33 2 1.13 1.13 50 0.51 0.51 NPS/DN Lbs/kg Lbs/kg 21/2 1.75 1.75 65 0.79 0.79 3 2.62 2.62 80 1.19 1.19 31/2 3.19 3.19 90 1.45 1.45 4 4.54 4.54 100 2.06 2.06 5 6.45 6.45 125 2.93 2.93 6 10.00 10.00 150 4.54 4.54 Note: See first page for pressure-temperature ratings. Galvanized weights may vary. Please contact your ASC Engineered SoLutionsiM Representative if you need verification. ALL Elbows & Tees I8' (10 DN) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) 101 asc-es.com Building connections that Last- PS-11.13 page 4 PS-SUB-1121-1122-1124-v0l 20220117 ASC. Engineered Solutions Fig. 1121,1122,1124 Couplings & Cap (CLass 150 Standard) General Assembly of Threaded Fittings 1 Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2 Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant maybe utilized. Throroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3 Joint Makeup For sizes up to and including 2 pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2 through 2 thread varies from 41/2 turns to 5 turns. For 21/2" through 4' sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4" thread varies from 51/2 turns to 6/4 turns. asc-es.com Building connections that Last- PS-11.13 page 5 Ps-suB-1121-1122-1124-v01 20220117 3. HANGERS & BRACING 21 Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring C®US LISTED Size Range - 1/2 thru 8' pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 5/8 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 3/8 10mm 73/8 5 1000 35 1/2 12mm 91/8 61/4 1250 66 1/2 12mm 101/8 63/4 1250 73 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com D SommyX-Press Revolutionizes The Pipe Handing Trades— The Sammy X-Press® System is designed to provide direct attachment of threaded rod in metal deck (22-16 gauge) and thin gauge purlin (18-16 gauge), while providing reduced installation costs in terms of time and materials. The X-Press Anchors eliminate the need for costly "armovers" in pipe hanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining nut on the threaded portion of the fastener to prevent pullout and are not designed for use in metal deck. In many instances, access to the backside of the installed fastener is prohibited by panel liner or roofing insulation. Sammy X-Press® anchors deliver the performance installers require without the use of a retaining nut! I Sammy X-Press The patent-pending X-Press Anchors consist of a threaded fastener and expandable sleeve. The X-Press System features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press® It Installation Tool assures a perfect installation every time offering the added convenience of one-tool efficiency - just drill and drive in seconds! SECONDS! ADVANTAGES D Installs in seconds, saving time & a Less jobsite material needed. installation costs. a No retaining nut required. a Use in applications where access to the back of 13 Provides design flexibility. the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Sammy's X-Press, Swivel and Sidewinder The Sammy X-Press expands to provide direct vertical attachment in: (XP) - Metal Deck (22-16 gauge) Patent No. 6,935,821 - Z-Purlin (18-16 gauge) The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: (SWXP) -89°inZ-Purlin PatenoPending 45° in metal deck for 12/12 pitch The Sammy X-Press Sidewinder expands EIVEME JPending to provide horizontal attachment in: OR - 16 ga - 3/16" steel - purlin, tubular steel. Roof ITIF Construction Products Call our toll free number 800-381-9692 or visit h vv vjAiwca it tictic ca for general information. SAMMYS 1. Pre-Drill. 2. Insert Anchor. 3. Install. Sammy X-Press Sprinkler Systems Pipes/Plumbing Electrical Lighting and Fixtures HVAC Equipment and Fixtures The X-Press System has earned the 91121 and 25E5 UL Listing. SAMMY X-PRESS IT INSTALLATION TOOL PART NUMBER MODEL DESCRIPTION EACH QTY 8194910 UXPIP Universal X-Press It Tool 1 8152910 XPDB 25/64' Drill Bit 1 *1001 Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit. SAfv1fv1YS Call our toll free number 800-387-96920, visit www.itwconstruction.ca for general information. [SE 1~0~NIGRW SAMMYS X-Press_Vertical_Mount ROD PART ULTIMATE TEST - - - - - - - ULMIN c FM MIN MAX BOX CASE APPLICATION MODEL DESCRIPTION PULLOUT LOAD THICK SIZE NUMBER (IBS) LISTED (LBS) (LBS) HICK THICK QTY QTY 1/4 1146 185 (Luminaire) .027 8181922 XP X-Press 200 .125' 25 125 Metal Deck (22 ga) 250 (Luminaire) .056" 850 (21/2" Pipe) .027' 940 (2" Pipe) 1146 185 (Luminaire) .027" 3/8' 8150922 XP 20 X-Press20 1475 (4"Pipe) 029" .125" 25 125 Metal Deck . (22 ga) 250 (Luminaire) .056" .104" 283 (Conduit & Cable) .029" 1500(4" Pipe) .060" 3/8" 8153922 XP 35 X-Press35 .125" 25 125 Purlin 1783 85 (Luminaire) .029" 940 (2 Pipe) .029" (16 ga) 250 (Luminaire) .056" 1475 (4" Pipe) .104" 416 (Conduit & Cable) .059" Metal Deck 3/8 " 8150922 XP 2O X-Press20 (22 ga) 850(2½Pipe) 1146 Pre-Pour Structural Concrete@ 3000 psi (Pre-Pour) Post-Pour Range II LWC!5 35 PCF (lbs/ft3) Metal Deck 25 125 I I I- (Post-Pour) A Sammy X-Press Pre-PourStmstural Conte @3000 pd Post-Pour Range II LWC!5 35 PCF (Ibs/ft) SAMMYS X-Press Swivel Head ® VOR Jhte.t1hending t'47%Mt ROOt ROD SIZE PART NUMBER MODEL DESCRIPTION ULTIMATE PULLOUT (LBS) ®js TEST LOAD LISTED (LBS) UL MIN TH ICK TEST uov (1.85) .M FM MIN THICK THICK . QTY QTY APPLICATION - 1250 (3-1/2" Pipe) 1675 250 vertical (Luminaire) Swivel (16 ga Vertical) 80 @90° (Luminaire) 3/8" 8295922 5XP35 X-Press35 1558 500 vertical .059' 635 (2" Pipe) .029' .125" 25 125 Purlin (89° Off Vertical) (Conduit & Cable) ( 333 @ 89° (Conduit & Cable) ROD I PART ULTIMATE SIZE NUMBER MODEL DESCRIPTION PULLOUT (LBS) I 5idewinder 3/8" 8293957 SWXP3S I 1798(l6ga) I X-Press35 TESTI TEST' I I LOAD MIN I MAX I BOX I CASE I APPLICATION (LBS) I (LBS) I I I&S LOAD' THICK I THICK I QTY I QTY I LISTED uvvnu 1250 (336" Pipe) I I 80 (Luminaire) I .060" I .125" I 25 I 125 I Purlin 416 (Conduit& Cable) I I I I I /ThWConstruction Products* Call our toll free number 800-387-9692 or visit www.itwconstnsction.ca for general information. SAMMYS FEATURES BENEFITS o Structural attachment and 0 Reduced installation cost. restraint component combined; D Design flexibility. ready for selected rod. 0 Less on site material (GO GREEN). 0 Access to the back of fastener 0 Less material coordination. not required. O Does not require use of a 0 Aesthetically pleasing. retaining nut. D Quick and easy installation. 0 SXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8 all thread (.299" OD) or end thread rod (.374" OD). SXP 35 for 3/8" Rod: Designed for use in steel purlin ranging from 16 ga. through 1/8" in low slope or pitched roof designs (12/12). The Swivels may be used to attach short length of rod to eliminate lateral sway bracing per NFPA 13, 9.3.5.3.8, (2007). FOR 3/8" ROD Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 450 from horizontal Material: Carbon Steel Screw Description: 1/4-20 x 1-1/8" with expandable sleeve Finish: Electro-Zinc Testing: Tested to GR-63-CORE Standard for performance in structural steel in seismic restraint applications as outlined for use in NFPA 13(2007), 9.3 at an independent test lab. The calculated force used for the testing was equal to that found in a Zone 4 and an 8.4 Richter scale seismic event. FM Listing for 3/8" Rod: UL 203 listed as pipe hanger File EX 5098 - SXP 35 (16 ga.) 0-90° from horizontal - 3-1/2" Schedule 40 pipe UL 203A File EX 15565 LISTED ROD I PART MODEL I SIZE NUMBER MIN THICKNESS MAX APPLICATION I Box CASE I I INSTALLATION TOOL THICKNESS QTY QTY The SWXP 35 must be installed 3/8' 8295922 SXP 35 16 ga 1/8" Purlin 25 1 125 with WIT Tool (Part No. 8194910); pre-drilling required. LEAST RADIUS OF MAXIMUM ROD LENGTH FOR hr (ft)__________ RESTRAINT SHAPE AND SIZE NOMINAL DIAMETER AREA (in.') GYRATION, r (in.) I/r'=lOO I I/r=200 ___________________________________ I I/r=300 IIr=400* 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 Rods(alithread) 1/21n. 0.129 0.101 0.8 I 1.7 I 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods(threadedatendsonly) 1/21n. 0.196 0.125 1.0 I 2.1 I 3.1 4.2 Reference: NFPA 13, (2007) Reference: NFPA 13, (2010) ITConstruction Products* I SAMMYSO Call our toll free number 800.387-9692o, visit www.itwconstruction.co for general information. SWXP 35 FOR 3/8" ROD Structural attachment for installation of branch/end of line restraint using 3/8" threaded rod. Used primarily in purlin, bar joist, or other steel structural members. These fastening systems provide a secure and economical attachment to the structure. The SWXP 35 model provides upper structural attachment in a range of steel thicknesses, from 16 ga. through 1/8". An expandable sleeve is included with each fastener, eliminating need for retaining nut. Restrained Pipe Size: Up to Schedule 40 pipe 2" or less Max Length of Restraint Material: See Maximum Horizontal Load Tables below. Maximum Angle: 45° from horizontal Material: Carbon Steel Screw Description: 1/4-20 X 1-1/8' with expandable sleeve Finish: Electro-Zinc (cap & screw) Testing: BX Report# R-1362 Listing: UL 203 as a pipe hanger G UL 203A pending LISTED SAMMYS X-Press for Seismic Rest ra [SE ROD I PART MODEL I SIZE I NUMBER MIN MAX THICKNESS I THICKNESS APPLICATION BOX I CASE INSTALLATION TOOL I QTY QTy The SWXP 35 must be installed 3/8 8293957 SWXP 35 16 ga. 1/8' Steel Purlin or Bar Joist 25 125 with IJXPIT Tool (Part No. 8194910); pre-drilling required. RESTRAINT SHAPE AND SIZE NOMINAL DIAMETER AREA On.") LEAST RADIUS OF GYRATION, r (in.) MAXIMUM ROD LENGTH FOR hr (ft) hr = 100 hr = 200 hr = 300 hr = 400* Rods (all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 Rods (threaded at ends only) 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 1/2 in. 0.196 1 0.125 1 1.0 2.1 3.1 4.2 Reference: NFPA 13, (2007) * Reference: NFPA 13, (2010) IT 7 Construction Products* (all our toil free number 800-387-9692 or visit www.Itwconstruction.ca for general information. SAMMYS