Loading...
HomeMy WebLinkAbout2598 STATE ST; ; FPC2023-0096; PermitPER]ET REPORT (ity of Carlsbad Print Date: 04/23/2025 Permit No: FPC2023-0096 Job Address: 2598 STATE ST, CARLSBAD, CA 920(8-1623 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2031012500 Track #: Applied: 05/16/2023 Valuation: $634,903.20 Lot t: Issued: 07/19/2023 Occupancy Group: Project #: DEV2022-0165 Finaled Close Out: 11/07/2024 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Robinson, Jarrod Plan Check #: Salcedo, Felix Cheung, Nathaniel Project Title: WILDLAND BAKERY AND LILO RESTARUANT Description: WILDLAND -SPRINKLER TI FOR RESTAURANT CONVERSION (182 HEADS) Applicant: FPContractor: A AND D FIRE PROTECTION INC THE HILLER COMPANIES LLC 713O CONVOY CT 14O GRAND ST, #STE300 SAN DIEGO, CA 92111-1019 WHITE.PLAINS, NY 10601-4840 (858) 277-3473 (251) 661-1275 FEE AMOUNT FIRE Hourly Services (first hour) $200.00 FIRE NFPA 13 or 13R System > 100 heads $774.00 Total Fees: $974.00 Total Payments To Date: $974.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Hydraulic Calculations for Project Name: WILDLAND Location: 2598 STATES STREET, CARLSBAD, CA.92008, Drawing Name: D3717 WILDLAND Design Remote Area Number: Calculation Date: 5/10/2023 Occupancy Classification Ordinary Group I Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.15 gpm/ft2 1500 ft2 (Actual 1533 ft2) 130 ft2 Pendent, Other 18 0 N/A gpm at Node: N/A 250.00 at Node: I Type: Allowance at Source (Safety Margin = 13.635) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 683.44 @ 72.931 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: A&D FIRE Address: 7130 CONVOY CT, SAN DIEGO, CA. 92111 Phone Number: 858-277-3473 Name of designer: BEN LEDESMA Authority Having Jurisdiction: CARLSBAD FIRE Notes: Automatic peaking results Left: N/A Right: N/A (© M.E.P.CAD, Inc. AutoSPRINK 2022 07.1.19.0 5/10/202311:28:56AM Page 1 Hydraulic Graph Job Name: WILDLAND N 1.85 Remote Area Number: Date: 5/10/2023 100- - I I Supply _____ Summary Sheet 90 T Static Pressure 88 000 Node: I 683.44 86.566 80 - © 72931 2250.00 75.000 70 683.44 with Hose Allowance at Source - - 601 50 CL 40 ystem demand cue______ 30- 20- b Z 1111111111 0450 900 1350 1800 2250 2700 3150 3600 4050 4500 Flow - gpm ,© M.E.P.CAD, Inc. jil AutoSPRINK 2022 07.1.19.0 5/10/2023 11:28:58AM Page 2 1111 Summary Of Outfiowing Devices Job Number: 1 Report Description: Ordinary Group Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 401 38.80 19.50 5.6 48.002 Sprinkler 411 24.25 19.50 5.6 18.749 Sprinkler 412 24.18 19.50 5.6 18.646 Sprinkler 413 23.65 19.50 5.6 17.842 Sprinkler 414 24.30 19.50 5.6 18.824 Sprinkler 431 22.31 19.50 5.6 15.876 Sprinkler 432 24.27 19.50 5.6 18.782 Sprinkler 434 20.36 19.50 5.6 13.218 Sprinkler 435 21.09 19.50 5.6 14.185 Sprinkler 436 39.59 19.50 5.6 49.981 Sprinkler 448 23.52 19.50 5.6 17.643 Sprinkler 449 23.47 19.50 5.6 17.560 Sprinkler 450 20.39 19.50 5.6 13.257 Sprinkler 451 22.21 19.50 5.6 15.729 Sprinkler 472 19.79 19.50 5.6 12.489 Sprinkler 473 21.57 19.50 5.6 14.833 c' Sprinkler 477 19.50 19.50 5.6 12.125 Sprinkler 478 20.19 19.50 5.6 13.002 c) Most Demanding Sprinkler Data (, © M.E.P.CAD, Inc. JIAutoSPRlNK 2022 07.1.19.0 5/10/2023 11:28:59AM Page 3 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 88.000 75.000 2250.00 86.566 683.44 72.931 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 4-0 Supply 72.931 433.44 401 11-10 Sprinkler 48.002 38.80 411 11-10 Sprinkler 18.749 24.25 412 11-10 Sprinkler 18.646 24.18 413 8-0 Sprinkler 17.842 23.65 414 8-0 Sprinkler 18.824 24.30 431 11-10 Sprinkler 15.876 22.31 432 11-10 Sprinkler 18.782 24.27 434 11'-10 Sprinkler 13.218 20.36 435 11-10 Sprinkler 14.185 21.09 436 11-10 Sprinkler 49.981 39.59 448 11-10 Sprinkler 17.643 23.52 449 11-10 Sprinkler 17.560 23.47 450 11-10 Sprinkler 13.257 20.39 451 11-10 Sprinkler 15.729 22.21 472 11-10 Sprinkler 12.489 19.79 473 11-10 Sprinkler 14.833 21.57 477 11-10 Sprinkler 12.125 19.50 478 11-10 Sprinkler 13.002 20.19 ,© M.E.P.CAD, Inc. LJ AutoSPRINK 2022 07.1.19. 5/10/2023 11:29:01AM Paçe 4 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (9pm) Notes 2 4-0 72.664 3 0-0 70.801 5 4-0 63.967 6 0-0 62.361 8 -2'-6 62.797 38 17-6 19.636 39 17-6 19.833 40 17-6 17.478 41 17'-6 18.650 50 16-6 24.858 51 15-6 25.033 52 15-6 25.728 53 15-6 27.352 54 15-6 30.427 55 15'-6 36.241 57 16-6 50.023 70 13-0 54.285 74 17-8 15.483 76 17-8 18.907 88 18'-1V2 12.571 90 18-1% 13.433 92 13-0 54.363 111 1851/2 12.278 ,© M.E.P.CAD, Inc. i.11 AutoSPRINK 2022 v17.1.19. 5/10/2023 11:29:01AM Page 5 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 113 1851/2 15.213 138 13'-O 54.824 184 13-0 55.039 268 13-0 55.333 314 13-0 55.367 317 13-0 55.377 353 13-0 55.985 ,© M.E.P.CAD, Inc. 1$J AutoSPRINK 2022 v17.1.19. 5/10/2023 11:29:01AM Paqe 6 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Pipe Information Node I El v I e (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as p flQgp+hfQ "U Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 477 11-10 5.6 19.50 i (See Notes) 21'-9 120 12.125 Route ..... Sprinkler, E(2'-4), T(5'-10) 8-2 0.106311 -2.734 88 1811/2 19.50 1.0830 29-11 3.180 88 1811/2 20.36 1 (See Notes) 59 120 12.571 Flow (q) from Route 4 T(5'-10) 5-10 0.399019 0.285 40 17'-6 39.86 1.0830 11-7 4.622 40 17-6 23.65 1 (See Notes) 2'0 120 17.478 Flow (q) from Route 12 PO(5'-l0) 5-10 0.944744 0.856 52 15-6 63.51 1.0830 7'-lO 7.395 52 15'-6 95.42 2 10-0 120 25.728 Flow (q) from Route 10 0.162335 53 15'-6 158.93 2.2030 10'-O 1.623 53 15-6 65.58 2 10'-O 120 27.352 Flow (q) from Route 3 0.307585 54 15-6 224.51 2.2030 10-0 3.076 54 15'-6 62.49 2 12'-0 120 30.427 Flow (q) from Route 2 0.484471 55 15-6 287.00 2.2030 12-0 5.814 55 16-6 68.05 2 (See Notes) 5'6Y2 120 36.241 Flow (q) from Route 7 P0(13-71/2) 1371,/2 0.718145 57 15'-6 355.05 2.2030 19'-2Y2 13.781 57 15'-6 4 (See Notes) 5861/2 120 50.023 9761/2 0.027339 1.088 13-0 355.05 4.3100 5E(13'-11), T(27'-10%)317 156-1 4.267 317 13'-0 78.39 4 (See Notes) 1- 5 120 55. 377 Flow (q) from Route 17 E(13'-11) 13-11 0.039543 353 13-0 433.44 4.3100 15'-4% 0.608 353 13'-O 6 15'-6 120 55.985 0.005958 6.720 8 -2-6 433.44 6.3570 15'-6 0.092 8 4-6 6 (See Notes) 65'1V2 140 62.797 2E(22'-l) 44-1% 0.004754 0.650 5 4-0 433.44 6.2800 109'-3 0.519 f, © M.E.P.CAD, Inc. AutoSPRINK 2022 07.1.19.0 5110/2023 11:29:03AM Page 7 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023• Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) __________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 5 4-0 6 (See Notes) 4-0 120 63.967 E(17'-7) j7'7 0.005958 -1.734 6 0-0 433.44 6.3570 21'-7 0.129 6 01-0 6 (See Notes) 4'2 120 62.361 BFP(-8.303), E(14'-O) 14'-0 0.007492 3 0,-0 433.44 6.0650 18'-2 8.439 3 01-0 6 (See Notes) 4'U 120 70.801 E(17-7) 0.129 17'-7 0.005958 1.734 2 4-0 433.44 6.3570 21'-7 2 4-0 6 (See 56'3 140 72.664 0.004754 -4'-O 433.44 F6,2800N otes) 1 56'-3 0.267 250.00 72.931 Hose Allowance At Source Total(Pt) Route I 1 683.44 472 11-10 5.6 19.79 1 (See Notes) 16-3 120 12.489 ••••• Route 2..... Sprinkler, E(2-4), T(5-10) 8-2 0.109255 -2.880 111 18'-5/ 19.79 1.0830 24'-5 2.669 111 18-5!"2 20.39 1 7'-0'/2 120 12.278 Flow (q) from Route 5 0.404975 0.351 74 17'-8 40.18 1.0830 2.854 74 17'-8 22.31 1 (See Notes) 37 120 15.483 Flow (q) from Route 9 T(5-10), P0(5-10) 11-8 0.916859 0.936 54 15-6 62.49 1.0830 15-3% 14.009 30.427 Total(Pt) Route 2 478 11-10 5.6 20.19 1 (See Notes) 19-9 120 13.002 "" Route 3"•• Sprinkler, E(2-4), T(5--1 0) 8-2 0.113402 -2.734 90 1811/2 20.19 1.0830 27'-ll 3.165 90 181h/2 21.09 1 (See Notes) 69 120 13.433 Flow (q) from Route 6 T(5'-10) 4.932 so 0.425795 0.285 41 17-6 41.28 1.0830 11-7 41 17-6 24.30 1 (See Notes) 2'0 120 18.650 Flow (q) from Route 16 PO(5'-l0) 5-10 1.002391 0.856 53 16-6 65.58 1.0830 7-10 7.846 , © M.E.P.CAD, Inc. AutoSPRINK 2022 v17.1.19.0 5/10/2023 11:29:03AM Page 8 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) I Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (13f) and shown as va' Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 27.352 Total(Pt) Route 3 434 11-10 5.6 20.36 1 (See Notes) 9111/2 120 13.218 Route 4•"•• Sprinkler, E(2'-4), T(5'-10) 8'-2 0.115140 -2.734 88 18'-l% 20.36 1.0830 181-1% 2.087 12.571 Total(Pt) Route 4 450 11'-10 5.6 20.39 1 (See Notes) 8-3% 120 13.257 ••• Route 5 ..... Sprinkler, E(2'-4), T(5'-10) 8'-2 0.115458 -2.880 111 18-5% 20.39 1.0830 16'-5% 1.901 12.278 Total(Pt) Route 5 435 11-10 5.6 21.09 1 (See Notes) 7'-ll% 1 120 14.185 Route 6 ..... Sprinkler, E(2'-4), T(5'-10) 8'-2 t 0.122911 -2.734 90 18-1% 21.09 1.0830 16'-l% 1.982 13.433 Total(Pt) Route 6 473 11-10 5.6 21.57 1 (See Notes) 17'-3 120 14.833 Route 7 ..... Sprinkler, E(2'-4), T(5'-10) 8'-2 0.128103 -2.879 113 18-5% 21.57 1.0830 25-5 3.258 113 18-5% 22.21 1 7'-0% 120 15.213 Flow (q) from Route 8 0.474602 0.350 76 17-8 43.78 1.0830 7-0% 3.344 76 17'-8 24.27 1 (See Notes) 3'7 120 18.907 Flow (q) from Route 15 T(5'-lO), P0(5-10) -8 ;151'3/2 1.073266 0.936 55 15-6 68.05 1.0830 16.399 36.241 Total(Pt) Route 7 451 11-10 5.6 22.21 1 (See Notes) 9'-3% 120 15.729 "" Route 8 Sprinkler, E(2'-4), T(5'-10) 8-2 0.135243 -2.879 113 18-5% 22.21 1.0830 17-5% 2.362 15.213 Total(Pt) Route 8 431 11-10 5.6 22.31 1 (See Notes) 7'-6 120 15.876 Route ..... Sprinkler, E(2'-4), T(5'-10) 8-2 0.136413 -2.529 74 17'-8 22.31 1.0830 15-8 2.136 15.483 Total(Pt) Route 9 (, © M.E.P.CAD, Inc. AutoSPRINK 2022 07.1.19.0 5/10/2023 11:29:03AM Page 9 Job Name: WILDLAND Remote Area Number: Date: 511012023 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) __________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) ________________ Friction(Pf) 449 11-10 5.6 23.47 1 (See Notes) 17-6 120 17.560 Route 10 ..... Sprinkler, E(2'-4), 2T(5'-10) 14-0 0.149739 -2.449 39 17'-6 23.47 1.0830 31-6% 4.722 39 17'-6 24.18 1 (See Notes) 2'0 120 19.833 Flow (q) from Route 13 PO(5'-10) 0.555127 0.856 51 15-6 47.65 1.0830 7'-lO 4.345 51 15-6 47.77 2 11-0 120 25.033 Flow (q) from Route 11 0.063167 52 15'-6 95.42 2.2030 11-0 0.695 25.728 Total(Pt) Route 10 448 11'-10 5.6 23.52 1 (See Notes) 15-6 120 17.643 ••"• Route ll•"•. Sprinkler, E(2'-4), 2T(5'-10) 14'-0 0.150401 -2.449 38 17'-6 23.52 1.0830 29'-6% 4.442 38 17'-6 24.25 1 (See Notes) 2'0 120 19.636 Flow (q) from Route 14 PO(5'-10) 5-10 0.557778 0.856 50 15'-6 47.77 1.0830 7'-lO 4.366 50 15-6 2 10-0 120 24.858 0.017564 51 15-6 47.77 2.2030 10'-0 0.176 25.033 Total(Pt) Route 11 413 8'-0 5.6 23.65 1 (See Notes) 1071/2 120 17.842 •... Route 12..... Sprinkler, E(2'-4), 2T(5'-10) 14'-0 0.151963 .4.111 40 17-6 23.65 1.0830 24'-8 3.747 17.478 Total(Pt) Route 12 412 11-10 5.6 24.18 1 (See Notes) 8111/2 120 18.646 Route 13 ..... Sprinkler, E(2'-4), 2T(5'-10) 14-0 0.158291 -2.449 39 17'-6 24.18 1.0830 22-11% 3.635 19.833 Total(Pt) Route 13 411 11-10 5.6 24.25 1 (See Notes) 6-11% 120 18.749 Route 14 ..... Sprinkler, E(2'-4), 2T(5'-10) 14'-0 0.159102 20'-11'/2 3.336 -2.449 38 17'-6 24.25 1.0830 19.636 Total(Pt) Route 14 , © M.E.P.CAD, Inc. AutoSPRINK 2022 07.1.19.0 5/10/2023 11:29:03AM Page 10 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) I Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ________________ Friction(Pf) 432 11-10 5.6 24.27 1 (See T Notes) I I 8-6 120 18.782 Route 15 ..... Sprinkler, E(2-4), T(5'-10) 8-2 0.159355 -2.529 76 17-8 24.27 1.0830 16'-8 2.654 18.907 Total(Pt) Route 15 414 8-0 5.6 24.30 1 (See Notes) 10-7% 120 18.824 Route 16••••• Sprinkler, E(2'-4), 2T(5'-10) 14-0 0.159683 -4.111 41 17'-6 24.30 1.0830 24-8 3.937 18.650 Total(Pt) Route 16 401 11-10 5.6 38.80 1 (See Notes) 7-4% 120 48.002 "" Route 17 ..... Sprinkler, 2E(2-4), PO(5'-10) 10'-6 0.379599 0.506 70 13'-0 38.80 1.0830 17'-lO% 6.789 70 13'-0 2 4'91,c 120 54.285 0.016303 92 13'-0 38.80 2.0670 4-9% 0.078 92 13'-0 39.59 2 7-8% 120 54.363 Flow (q) from Route 18 0.059885 138 13-0 78.39 2.0670 0.461 138 13'-0 2% 8'-6 120 54.824 0.025203 184 13-0 78.39 2.4690 8'-6 0.214 184 13'-0 3 (See Notes) 29'-6 120 55.039 2E(10'-6) 0.005837 268 13'-0 78.39 3.3340 50-6 0.295 268 13-0 4 (See Notes) 4'51/2 120 55.333 E(1 0'-O) 101-0 0.002330 314 13'-0 78.39 4.0260 14'- 51/2 0.034 314 13'-0 6 (See Notes) 2'-11 Y2 120 55.367 T(30'-O) 30'-0 0.000317 317 13-0 78.39 6.0650 32-11% 0.010 55.377 Total(Pt) Route 17 436 11-10 5.6 39.59 1 (See Notes) 4-2% 120 49.981 J Route 18..... I Sprinkler, I E(2'-4), PO(5'-10) 8'-2 0.394056 -0.506 92 13-0 39.59 1.0830 12-5 4.888 , © M.E.P.CAD, Inc. J AutoSPRINK 2022 07. 1.19.0 5/10/2023 11:29:03AM Page 11 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023' Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) __________ Fitting/Device (Equivalent (q) Equiv. Length) Fixed Pressure Losses, Fitting (Foot) Pt Friction Elev(Pe) Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to (P0 and shown as 54.363 Total(Pt) Route 18 (/, © M.E.P.CAD, Inc. t5l AutoSPRINK 2022 v17.1 .19.0 5/10/2023 11:29:03AM Page 12 Job Name: WILDLAND Remote Area Number: Date: 5/10/2023 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) IC Value Multiplier I Actual Inside Diameter 487 Factor Value Of C 100 130 140 150 I \ = Schedule 40 Steel Pipe Inside Diameter / I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow ME 45° FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant L(E Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. 1 J AutoSPRINK 2022 v17.1.19.0 5/10/2023 11:29:03AM Page 13 FIRE SPRINKLERS INC. WILDLAND 2598 STATES STREET CARLSBAD, CA. 92008 FIRE SPRINKLER SUBMITTAL PRODUCT DATA ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. 1. FIRE SPRINKLERS AND ACCESSORIES tqciclo Worldwide Contacts www.tyco4ire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the OR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp172 General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IAD1tLW The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT 1Y323. . . . Pendent 5.6K, 1/2 in. NPT Technical Data Approvals See Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi'/2 (80,6 LPM/bar½) Temperature Rating See Table A Finishes Sprinkler: See Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze Page 1 of 4 SEPTEMBER 2022 TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector, can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15or20 RECESSED ESCUTCHEON 1 7/16 (11,1 mm) NOMINAL MAKE-IN 2" (50,8 mm) 1/2' NPT** 2' (50,8 mm) N! / WRENCH FLATS DEFLECTOR * j— 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TV313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 2-7/8' DIA. (73,0 mm) 2-1/4' DIA. FACE OF - (57,2 mm) 5/8 (15,9 mm) SPRINKLER FITTING ________ —I FL1SH 3/8±5/16" (9,5±7,9 mm) /- MOUNTING 1/8" J I SURFACE - (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) (7,9±6,4 mm) _#(3,72/8m 1/2" (12,7 mm) FLUSH !1/ MOUNTING " SURFACE m) I CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyesterc 5.6 1/2 in. NPT UPRIGHT (TY313) and PENDENT (TY323) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6,7 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY323) Figures 4a and 5b 135°F (57°C) Orange 1,2,3,4,7 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories. Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06( as Quick Response Sprinklers. EAC Approved. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NPT( 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench as shown in Figure 2. Apply the W-Type 6 Sprinkler Wrench to the wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench as shown in Figure 3. Apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats as shown in Figure 1. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N-m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI72 Page 4 of 4 P/Na 77_XXX_X_XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS I 370 5.6K UPRIGHT (1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F (57°C) PURE WHITE (RAL9010)a 371 5.6K PENDENT (1/2 in.NPT) TY323 3 POLYESTER 155 155°F (68°C) Notes: a. Use suffix "I" for ISO 7-1 connection; for example, SIGNAL WHITE (RAL9003) POLYESTER 175 175°F (79°C) 77-370-4-175-I JET BLACK (RAL9005) POLYESTER 200 200°F (93°C) 9 CHROME PLATED 286 286°F (141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 02022 Johnson Controls. All rights reserved. All specifications and Other Information shown were current ansi document revision date and are subject to change withoot notice. NATIONAl. FIRE PROTECTION ASSOCtOTION end NFPA are registered trademarks 01 N*,IovnI 5,5 protector, Association; Isol,odnvrnde of The Chsv,ou,s Company FC, LLC Johnson 00to Controls tqco® Worldwide Contacts I www.tyco-fire.com TFPI 72 Change History Appendix ISSUE DATE NOTES 09-22 Page 1, updated QR code and URL; Page 3, Table A, added EAC Approved; Page 4, changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 1 Telephone +1-401-781- 8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700. 11-21 Added OR code and URL to allow convenient access to electronic version from printed document. 08-18 Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer stating specifications and information subject to change without notice; Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300. 02-18 Changed Recessed Pendent (TY313) to Recessed Pendent (TY323) in Type column of Table A. 07-17 Added Table A to organize Laboratory Listings and Approvals; Changed existing Part Number Selection table designation to Table B; Added Jet Black (RAL9005) Polyester sprinkler finish option. 02-14 Added note to indicate sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion Resistant Sprinklers; Added LPCB Approval. 01-13 Changed note in Ordering Procedure Part Number Selection table to indicate special order ISO thread sprinklers may be ordered by adding an I suffix code to Part Numbers, formerly described as prefix. 12-12 Rev A Added C-UL Listings and reference to Intermediate Level sprinkler data sheets. 12-12 New Technical Data Sheet TFP172 describes Series TY-FRB Quick Response 5.6 K-factor (K80) Stan- dard Coverage TY313 Upright and TY323 Pendent and Recessed Pendent Sprinklers 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 Johnson Alkil 02022 Johnson Controls. All rights resersod. All specifications and other information shown were current as of document revision date and are subject to change without notice. Controls Victaulic® FireLock Model FL-QR/C Standard Coverage, Quick Response Concealed Pendent Sprinklers, K5.6 (8.1) JA C- tauIic 41.03 1.0 PRODUCT DESCRIPTION QUICK RESPONSE CONCEALED PENDENT SPRINKLERS SIN V5606 V3802 V3808 ORIENTATION Concealed Pendent ealed Pendent Concealed Pendent K-FACTOR' 5.6 Imp./8.1 S.I. Imp-J8.1 S.I. E1/2" 5.6 Imp./8.1 S.!. CONNECTION ½" NPTf15mm BSPT PT/l5mm BSPT ½" NPT/l5mm BSPT MAX. WORKING PRESSURE 175 psi (1200 kPa) psi (1200 kPa) 300p!1 (2068 kPa) ESCUTCHEON Concealed Concealed Concealed GLOBE RE-DESIGNATED GL5606 - - GLOBE EQUIVALENT - GL5604 GL5605 AVAILABLE WRENCHES SPRINKLER 1" ADJ Concealed V38 Concealed V38 Concealed PENDENT CLEAN ROOM GASKET SPRINKLER 1 ADJ Concealed V38 Concealed V38 Concealed PENDENT U U Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: UL/FM: 7ps1148 kPa/.5 bar Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. viCtaulic.com 41.03 16369 Rev D Updated 02/2023 02023 Victaulic Company. All rights reserved. 1 x Ac--tau-hlc~- victaulic.com 2.0 CERTIFICATION/LISTINGS cus B (E UK USTED APPROVED CA LPS 1186: Issue 3.1 Cert/LPCB Ref. 100106 APPROVALS/LISTINGS SIN V5606 Cover Plate V3802 V3808 Cover Plate Nominal K Factor Imperial 5.6 - - 5.6 5.6 - Nominal K Factor S.1.2 8.1 - 8.1 8.1 - Orientation Pendent - Pendent Pendent - Escutcheon Concealed - Concealed Concealed - APPROVED TEMPERATURE RATINGS F°/C° 135°F/57°C 135°F157°C 135°F157°C 135°F/57°C 135°F157°C 155°F/68°C 135°F /57°C Ii 55°F/68°C 155°F/68°C 155°F168°C 135°F157°C cULus 175°F/79°C 155°F/68°C 175°F/79°C 175°F179°C 165°F/74°C 200°F/93°C 155°F/68°C 200°F/93°C 200°F193°C 165°F/74°C FM 155°F/68°C 135-F /57-C I 155°F/68°C 155°F/68°C 135°F/57°C Standard Response Only 175°F/79°C 155°F/68°C 175°F/79°C - 135°F/57°C Ii 65°F/74°C 200°F/93°C —__155°F/68°C 200°F/93°C 165°F/74°C 155°F/68°C 138°F/59°C LPCB - - 175°F179°C - 165°F174°C 200°F193°C 165°F/74°C 155°F/68°C 138°F/59°C CE - - 175°F179°C - 165°F174°C 200°F/93°C 165°F174°C CCC 155°F/68°C 135°F/57°C K ZSTDY - - 200°F/93°C - 135°F/57°C I165°F/74°C APPROVALS/LISTINGS WITH CLEAN ROOM GASKET SIN V38023 V38083 Cover Plate Nominal K Factor Imperial 5.6 5.6 - Nominal K Factor 5.1.2 8.1 8.1 - Orientation Pendent Pendent - Escutcheon Concealed Concealed - APPROVED TEMPERATURE RATINGS F°/C° cULus 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 135°F/57°C 155°F/68°C 175°F/79°C 200°F/93°C 135°F/57°C 135°F/57°C 165°F/74°C 165°F/74°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. Recognized as standard response when clean room gasket is installed. NOTES Listings and approval as of printing. New York City Acceptance - All UL Listed and/or FM Appwroved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the OTCR Rule. 41.03 16369 Rev D Updated 02/2023 © 2023 Victaulic Company. All rights reserved. victaulic.Com 2 \ftauIic victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze Bulb Nominal Diamter: 3.0 mm Load Screw: Brass Pip Cap: Brass Spring Seal: PTFE coated Beryllium nickel alloy Frame: Brass Concealed Cup: Steel Cover Plate: Steel Lodgement Spring: Stainless Steel Pin: Stainless Steel Installation Wrench: Ductile Iron Sealing Gasket: White nitrile (CLEAN ROOM USE ONLY) Cover Plate Finishes: Chrome plated White painted Flat black painted Custom painted NOTE For cabinets and other accessories refer to separate sheet. 4.0 DIMENSIONS 1y6/g mm 2/8/6O mm Hole in ceiling Cup --f1 Lodgement Spring _ Pip cap and ji spring seal 'N Bulb—. Frame Pin -. Typical ceiling - 2W/61 mm Load Screw —... 1W/48 mm Cover plate l--'3Y4/82 mm ___________ "-. Finished surface V3802, V3808 V3802, V3808 41.03 16369 Rev D Updated 02/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 3 \ 06 tauljc nm nm WI 4 mm WI 4 mm victaulic.com 4.0 DIMENSIONS (CONTINUED) 2W160 mm 2/5l mm - Hole in ceiling 1wI 48 mm Cup _\ Pip cap and 'i spring seal I Lodgement spring Bulb - Frame Load screw 2W169 mm 1718'747 mm Pin Deflector - Typical ceiling Cover plate 2W/70 mm ________ - Finished surface L A-/ 4 mm V5606 Finished surface Activated Position V5606 47102 mm 2W/73 mm Seismic Coverplate Large Coverplate V5606 V5606 41.03 16369 Rev D Updated 02/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 4 \JtauIic 41.03 16369 Rev 0 Updated 02/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS WARNING US Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -67°F/-55°C. 41.53: Victaulic® FireLock°M Series FL-SR/C 1-40: Victaulic FireLockTM Automatic Sprinklers Installation and Maintenance Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination onto the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries, tqca R Suppression re & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 56K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response (5 mm Bulb) and Standard Coverage, are decorative glass bulb automatic sprin- klers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures; for example, sprinkler drops from unheated portions of buildings sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors sprinklers are used on systems that are seasonably drained to avoid freezing; for example, vacation resort areas L'L.1lDJ Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. the standards of any other Authorities Having Jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SINs) TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved: Ref No. 094a/11 CE Certified: EN 122.59-1 NYC Approved under MEA 352-01-E Refer to Table A. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1-inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/p5i112 (80,6 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated, Chrome Plated, Brass Plated Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing ...............Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw.......... Bronze Deflector.................Bronze Frame ...................Bronze Guide Tube.........Stainless Steel Water Tube .........Stainless Steel Spring.............Stainless Steel Sealing Assembly. . . Beryllium Nickel wrreflon Escutcheon ..........Carbon Steel DuPont Registered Trademark Page 1 of 10 MAY 2011 TFP500 TFP500 Page 2 of 10 TY3255 Pendent TY3255 Pendent TY3355 Horizontal Sidewall with top of Deflector-to-Ceiling with Standard with Standard Escutcheon distance of 4 to 12 inches Recessed Escutcheon (Figure 5) (100 to 300 mm) (Figure 3) with Wide Flange with Deep Escutcheon with Standard Escutcheon Recessed Escutcheon (Figure 6) (Figure 9) (Figure 4) without Escutcheon with Deep Escutcheon Temperature Bulb Color (Figure 7) (Figure 10) Rating Code TY3155 Upright without Escutcheon (Figure 13) without Escutcheon (Figure 8) SPRINKLER FINISH Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F (57°C) Orange 1,2,3,5 1,2,5 1,2,3,4,5 1,2,4,5 1*,2*,3**,4,5 1*2*4,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue N/A 4, 5 360°F(182°C) Mauve N/A 1',2-,5 N/A Notes Listed by Underwriters Laboratories, Inc. (maximum order 4. Loss Prevention Certification Board and CE conformity length of 48 inches) apply to these temperature ratings only Listed by Underwriters Laboratories for use in Canada 5. Approved by the City of New York under MEA 352-01-E (maximum order length of 48 inches) * Light and Ordinary Hazard Occupancies Only Approved by Factory Mutual Research Corporation ** Light Hazard Occupancies Only (maximum order length of 48 inches) N/A - Not Available TABLE A SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS - LABORATORY LISTINGS AND APPROVALS - PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER II II TUBE CASING GUIDE - INSERT TUBE BULB FRAME SEAT 5 mm BULB VENT HOLE _____ COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 STANDARD RESPONSE DRY-TYPE SPRINKLERS - ASSEMBLY - - WRENCH RECESS WRENCH - I FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING -c ORDER LENGTHS: 5' to 48' (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM - 1-3/4" (44,5 mm) - DEFLECTOR TO CEILING TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48' (127,0 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) TFP500 Page 3 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ________________ L i ORDER LENGTHS: 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF CEILING 2-3/16" ± 1/8" 3' DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT TY3255 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4" to 48 (95,3 to 1219,2 mm) IN 1/4(6,4mm) 2-1/4' DIA. INCREMENTS (57,2 mm) FACE OF CEILING FIGURE 4 PENDENT TY3255 WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" (88,9 mm) - (12,7 to 1168,4 mm) IN 1/4' (6,4 mm) 2-1/2" DIA INCREMENTS _________ FACOF _ ,5mm CEILING 4-1/4' ± 1/8" (108,0 ± 3,2 mm) FIGURE 5 PENDENT TY3255 WITH DEEP ESCUTCHEON FIGURE 6 FIGURE 7 PENDENT TY3255 UPRIGHT TY3155 WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON ORDER LENGTHS: FACE OF 1/2"t045-3/4"(12,7t01162,1 mm) MOUNTING IN 1/4" (6,4 mm) INCREMENTS SURFACE 4-13/16" (122,2 ± 3,2 mm) 2-1/2" DIA. FACE OF SPRINKLER FITTING 1 71~ 3-1/2" DIA. (88,9 mm) SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) / 5/16" / (7,9 mm) CENTERLINE OF WATERWAY FIGURE 10 TY3355 HORIZON1TAL SIDEWALL WITHOUT ESCUTCHEON TFP500 Page 4 of 10 ORDER LENGTHS: 2-3/4 to 48" (69,9 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS 4" ± 1/8" (101,6 3,2 mm) FACE OF 1-3/4' DIA. FACE OF ± - SPRINKLER MOUNTING (44,5 mm) FITTING SURFACE d. ______ / 3" DIA. —1 (76,2 mm) SPRINKLER FITTING R_ (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 TY3355 HORIZONTAL SIDEWALL WITH STANDARD ESCUTCHEON Operation When TYCO Series DS-1 Dry-Type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Figure 1) in the Inlet of the Sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allowing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 Dry-Type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 require- ments. For more information on LPCB Approval, contact TYCO Fire Suppression & Building Products at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1-inch NPT Series DS-1 Dry-Type Sprinklers are to be installed in the 1-inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). Do not install Series DS-1 Dry-Type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. You can also install Series DS-1 Dry-Type Sprinklers in the 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. ORDER LENGTHS: I 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF i- SPRINKLER FITTING MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE TFP500 Page 5 of 10 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area' 40°F (4°C) 50°F (10°C) 60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)2 40-F (4-C) 0 0 0 30°F (-1°C) 0 0 0 20°F (-7°C) 4 (100) 0 0 10°F (-12°C) 8 (200) 1 (25) 0 0°F (-18°C) 12 (305) 3 (75) 0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C) 16 (405) 8 (200) 4 (100) -40°F (-40°C) 18 (455) 8 (200) 4 (100) -50°F (-46°C) 20(510) 10(255) 6 (150) -60°F (-51°C) 20(510) 10(255) 6 (150) Notes For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE B EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS - MINIMUM RECOMMENDED LENGTHS - The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1-inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating Series DS-1 Dry-Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. Lr.1tL.1 Do not install Series DS-1 Dry-Type Sprinklers into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: Failure of the sprinkler to operate prop- erly due to formation of ice over the Inlet Plug or binding of the Inlet Plug. Insufficient engagement of the Inlet pipe-threads with consequent leakage. Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing temperatures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table B to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed barrel length measure- ment must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 6 of 10 FACE OF SPRINKLER - - FITTING Ir a EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES Ali ------------ ~:Tu FIGURE 11 - EXPOSURE LENGTH - RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) PI DSB-2 INTENDED FOR FREEZER 4 • STRUCTURES FIGURE 12 SPRINKLER FITTING - UNHEATED AREA - TO WET SIDE SYSTEM OUTLET ,LUGGED DSB-2 - SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) FIGURE 13 SPRINKLER FITTING - HEATED AREA - STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ISB-2 BOOT ADHESIVE 1-3/4 DIA. (44,5 mm) LEARANCE HOLE NSULATED FREEZER TRUCTURE DS-1 HOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS- 1 DRY-TYPE SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE I STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON DS-i OPPOSING SHOWN WITH SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 7 of 10 Installation TYCO Series DS-1 Dry-Type Sprinklers must be installed in accordance with the following instructions. NOTICE Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1-inch NPT sprinkler joint by applying a minimum-to- maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendic- ular to the back wall and parallel to the ceiling. Ensure the word 'TOP" on the Deflector faces the ceiling. With a non-hardening pipe-thread sealant such as Teflon applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Figure 1). the W-Type 7 Sprinkler Wrench on the Wrench Flat (Figure 2). Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guide- lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling/ wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 Dry-Type Sprinklers must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Exercise care to avoid damage before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section in this data sheet. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other Authorities Having Jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. *DuPont Registered Trademark TFP500 Page 8 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression and Building Products (TFSBP) are warranted solely to the original Buyer against defects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire twelve (12) months from installation or eighteen (18) months from delivery, whichever occurs first. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possi- bility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or imDlied, including warranties of merchantability and fitness for a partic- ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, including description and Part Number (P/N). Dry Sprinklers When ordering 5.6 K-Factor Series DS-1, Standard Response , Standard Coverage (5 mm Bulb), Dry-Type Automatic Sprinklers, specify the following information: Model/SIN Pendent TY3255, Upright TY3155, or Horizontall Sidewall TY3355 Deflector Style Order Length Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections 1-inch NPT or ISO 7-R1 Temperature Rating Sprinkler Finish Escutcheon Style and Finish, as applicable Part Number from Table B. Part numbers are for i-inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accom- panied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (a suffi- cient quantity for installing one boot). SPRINKLER FINISH NATURAL BRASS WHITE POLYESTER CHROME PLATED CHROME PLATED NATURAL BRASS ESCUTCHEON FINISH (1) WHITE WHITE CHROME WHITE BRASS PLATED TEMPERATURE RATING (2) 0 135°F (57°C) 1 155°F(68°C) 2 175°F(79°C) 3 200°F (93°C) 4 286°F (141°C) 5 360°F (182°C) ORDER LENGTH (3) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" TFP500 Page 9 of 10 P/N* 60 - XXX - X - XXX _[_ MODEL/SIN j 96 Pendent with Standard 1Y3255 1 Escutcheon (1" NPT) (Figure 3) 93 Pendent with Deep 1Y3255 4 Escutcheon (1" NPT) (Figure 5) 97 Pendent with Standard 1Y3255 Recessed Escutcheon (1' NPT) (Figure 4) 92 Pendent without TY3255 0 Escutcheon (1° NPT) (Figure 6) -r Sidewall with Standard TY3355 94 Escutcheon (1° NPT) (Figure 8) 53 Sidewall with Deep TY3355 Escutcheon (1" NPT) (Figure 9) 54 Sidewall without TY3355 - Escutcheon (1" NPT) (Figure 10) 98 Upright without TY3155 Escutcheon (1 NPT) _T (Figure 7) Notes * Use Prefix "I" for ISO 7-R1 Connection; for example, 1-60-961-1-180). Escutcheon Finish applies to sprinklers provided with escutcheons. 286°F (141°C) and 360°F (182°C) temperature ratings apply to non-recessed sprinkler assemblies. Dry-Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 10, as appli- cable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. TABLE C SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS - PART NUMBER SELECTION - TFP500 Page 10 of 10 Copyright © 2007, 2011 Tyco Fire Suppression & Building Products. All rights reserved. 2. PIPE AND FITTINGS. APPROVALS AND SPECIFICATIONS ASTM A135, Grade A ASTM A795, Type E, Grade A Pressure rated to 300 psi Underwriters Laboratories- United States of America Underwriters Laboratories-Canada Factory Mutual NFPA-13 NFPA-13R NFPA-14 CIVIL DEFENSE APPROVAL- United Arab Emirates Made in the United States of America UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, preaction and deluge sprinkler systems. LEED v4 Certified SCHEDULE 10 & 40 SPRINKLER PIPE SUBMITTAL DATA SHEET FINISHES AND COATINGS Schedule 10 & 40 Sprinkler Pipe receives an OD mill coating of water-based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. Schedule 10 & 40 Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. EG2 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. Schedule 10 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION Every length of Bull Moose fire sprinkler pipe features large, easy-to- read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. 010 'j OZD UM 0.0. (in) 1.315 1.660 1.900 2.315 2.815 3.500 4.500 6.625 8.625 Empty weight (lb/ft) -. 1.091 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 Water Filled Weight (Ih/ft) 1.800 2.518 3.053 4.223 5.893 1.951 11.796 23.030 40.086 - CAR.* - Pieces per Lift 0.0(m) 15.27 9.91 1.76 6.27 4.92 3.54 2.50 1.158 1.805 91 61 61 37 30 19 19 10 1 1315 1.660 1.900 2.375 2.815 3.500 4.500 - ID. (in) 1.049 1.380 1.610 2.061 2.469 3.058 4.026 Empty Weight (lb/ft) 1.680 2.270 2.120 3.660 5.800 1.580 10.800 Water Fitted Weight (lb/ft) 2.055 2.910 3.602 5.114 1.815 10.183 16.316 - - - C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Piecesper Lift 1 10 51 1 44 30 30 1 19 19 *calculated using standard UL CRR formula, UL Fire Protection Directory, category VIZY **Not Eddy Guard II treated/Not produced by BMT SUBMITTAL INFORMATION @) c(J <) A-OVID Project I Contractor L Engineer Specification r Reference Date System Type L Locations [ Comments (J Schedule 10- Black 0Schedule 10- Hot Dip Galvanized (J Schedule 40- Black (J Schedule 40-Hot Dip Galvanized EULLIV[DOSETUBECDM Ii4i1tc I " 3. HANGING AND BRACING. Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or10mm 31/8 2/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm U8 2/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 11/2 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 7/8 51/4 600 34 4 3/8 10mm 7/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.137.5599 • FAX: 951131.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Model K Lateral Sway Brace Fig. AF035 PPROVED 4114 Engineered Solutions Material Specifications Size Range: Service Pipe Size: 1" - 12" Brace Member: 1" - 2" MateriaL Ductile Iron Casting with Carbon Steel Strap and Hardware Finish 0 Plain 0 Electro-Galvanized Service A seismic lateral brace designed to connect a brace member to the service pipe. The AF035 rigidly braces steel and CPVC piping systems subjected to horizontal and vertical seismic loads. Approvals cULus Listed (ANSI/UL 203a) and FM Approved (FM 1950-13). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing requirements. Features The set screw provides a visual indication that proper installation has been achieved Rounded edge design eliminates potential for abrasion of CPVC pipe Patents No. 7,516,922, No. 7,523,895 Ordering Specify figure number, service pipe size, brace size, finish, and description. 1' (0N25) to 3" (DN80) Service Pipe 4" (DN100) to 12" Service Pipe AFCON. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: 0 Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: 55-04.21 page 1 5S-SUB-AF035-03 20220408 iiBia:cs 4 Engineered Solutions Model K Lateral Sway Brace Fig. AF035 FIG. AF035: Weight Per Size Brace Member Size Service Pipe Size - V' (DN25) 114°(DN32) 1W' (DN40) 2' (0N50) (DN25) 1.60 lbs 1.80 lbs 2.00 lbs 2.28 lbs 11/4 (0N32) 1.68 lbs 1.88 lbs 2.08 lbs 2.36 lbs 1W (DN4O) 1.64 lbs 1.84 lbs 2.04 lbs 2.32 lbs 2' (ON 50) 1.88 lbs 2.08 lbs 2.28 lbs 2.56 lbs 21/2' 1.90 lbs 2.10 lbs 2.30 lbs 2.58 lbs DN65 2.00 lbs 2.20 lbs 2.40 lbs 2.68 lbs (DN8O) 2.10 lbs 2.30 lbs 2.50 lbs 2.78 lbs (ON100) 2.18 lbs 3.38 lbs 3.58 lbs 3.76 lbs (DN1 25) 3.40 lbs 3.60 lbs 3.80 lbs 4.08 lbs DN150 3.80 lbs 4.00 lbs 4.20 lbs 4.48 lbs 6' 3.90 lbs 4.10 lbs 4.30 lbs 4.58 lbs DN200 4.70 lbs 4.90 lbs 5.10 lbs 5.38 lbs 8' 4.80 lbs 5.00 lbs 5.20 lbs 5.48 lbs 10' 5.60 lbs 5.80 lbs 6.00 lbs 6.28 lbs 12' 6.16 lbs 6.36 lbs 6.56 lbs 6.84 lbs Mi asc-es.com Building connections that Last- 55-04.21 page 2 SS-SUB-AF035-03 20220408 Lateral Application Lateral Application Riser Application 4 Model K Lateral Sway Brace Fig. AF035 FIG. AF035 cULus Listing per ANSI/UL 203a (ASD) Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Pipe Size Service 45"-59" 60"-90" Listed Pipe Pipe lbf/kN lbffkN lbf/kN lbfIkN Sch. 10 Mega-Thread 1 Sch. 40 MLT/GL (DN25) CPVC Eddy Thread Metric Pipe EZ-Thread Mega-Flow Sch. 10 MLT/GL 11/4 Sch. 40 Mega-Thread (0N32) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Mega-Flow Sch 10 MLT/13L 11/2 Sch 40 Mega-Thread (DN40) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 625 884 1082 1250 - ________ - 278 3.93 4.81 5.56 Mega-Flow Sch 10 MLT/GL 2 Sch. 40 Mega-Thread (DN50) cvc Eddy Flow Metric Pipe E Eddy Thread EZ-Thread Fire-Flo Sch. 10 Mega-Flow 2W Sch. 40 Eddy Flow CPVC Fire-Flo 0N65 Metric Pipe Sch. 10 - 31, Sch. 40 Mega-Flow (DN8O) cvc Eddy Flow Metric Pipe Fire-Flo Sch. 10 Mega-Flow DN1O0 Sch. 40 Eddy Flow Metric Pipe Fire-Flo Sch. 10 Sch. 40 'DN125 - / Metric Pipe DN150 Metric Pipe - 942 1333 1632 1885 419 5.93 7.26 8.38 Sch. 10 Sch. 40 Mega-Flow 0N200 Metric Pipe - 8" 0.188 wall - Sch. 40 10 0.188" wall - Sch. 40 - 12 0.188 wall 1125 1591 1948 2250 Sch. 40 5.00 708 867 1001 Brace Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table below for UL listed specialty pipes & UL Listed metric service pipes. Load Ratings reflect 1" (DN25) - 2" (DN50) brace members. See table below for listed brace members. Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. ~00 0A Engineered Solutions asc-es.com Building connections that Last- SS-04.21 page 3 ss-suB-AF035-43 20220408 Lateral Application Lateral Application Riser Application SA~r&l fK71MC-1-30' — MiSMIX Model K Lateral Sway Brace Fig. AF035 FIG. AF035 cULus Listing Per UL 203a (ASD) For NFPA 13-2016 Editions Or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 13. The 2016 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition. The toad ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 203A, Outline of Investigation for Sway Brace Devices fbr Fire Sprinkler System Piping, based upon a minimum safety factor of 1.5 in accordance with the earlier editions of NFPA 13. The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority Having Jurisdiction (AHJ). Service Standard Speicalty Horizontal Load Rating at Brace Angle Pipe Size Service Service 30-44 45-59° 60-74 75-90 Pipe p Ibf/kN lbf/kN lbflkN IbI/kN Sch 10 Mega-Thread Sch 40 MLT/GL (DN25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow 1W Sch 10 MIT /GL Mega-Thread (DN32) Sch. 40 Metric Pipe Eddy Flow Eddy Thread EZ-Thread Mega-Flow MLT/GL 1W Sch. 10 Mega-Thread (DN40) Sch. 40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Mega-Flow MIT /GL Sch. 10 Mega-Thread (01450) Sch. 40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 1382 1955 2393 2765 Sch. 10 Mega-Flow 6.15 8.70 10.65 15.52 2%' Sch. 40 Eddy Flow Metric Pipe Fire-Flo DN65 Metric Pipe - Sch. 10 Mega-Flow '0N80' Sch. 40 Eddy Flow Metric Pipe Fire-Flo Sch. 10 Mega-Flow 'DNlOO' Sch. 40 Eddy Flow Metric Pipe Fire-Flo Sh.10 'D14125 ' Sch 40 - Metric Pipe DN150 Metric Pipe - 6' Sch.10Mega-Flow DN200 Metric Pipe - 8 0.188' Wall - Sch. 40 0.188" Wall - 12 0.188' Wall - 1870 2644 3238 3740 Sch. 40 8.32 11.77 14A0 16.64 Brace Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Listed load ratings reduced for angle ranges in accordance with NFPA 13-2016 Section A.9.3.5.2.3. See table below for UL listed specialty pipes & UL Listed metric service pipes. Load Ratings reflect 1" (DN25) - 2" (DN50) brace members. See table below for listed brace members Minimum safety factor of 2.2 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. Engineered Sol.utions mc HMO asc-es.com Building connections that Last- SS-03.22 page 4 SS-SUB-AF035-v03 20220408 Lateral Application Lateral Application Riser Application. 4 Model K Lateral Sway Brace Fig. AF035 FIG. AF035 FM Approved (Listing) per FM 1950-13 (ASD) Horizontal l Load Rating at Brace Angle Standard Speicalty - — Service Pipe Size Service Service 30"-44" 45"-59" 60"-74" 75"-90" Pipe Pipe - - - tbf/kN bf/kN Ibf/kN IbfIkN Sch 10 Mega-Thread 1 Sch. 40 MLT/GL (0N25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow 1650 2350 2880 3210 Sch 10 MLT/GL 7.38 10.45 12.81 14.28 Sch. 40 Mega-Thread (DN32) Metric Pipe Eddy Flow Eddy Thread Mega-Flow MLT/GL itS Sch. 10 Mega-Thread Sch. 40 Eddy Flow (0N40) Metric Pipe Eddy Thread EZThread Fire-Flo 1540 2170 2660 2970 Mega-Flow 6.85 9.65 11.83 13.21 MILT /GL Sch. 10 Mega-Thread 2 Sch. 40 Eddy Flow (DNSO) Metric Pipe Eddy Thread EZ-Thread Fire-Flo Sch 10 Mega-Flow 2tS Sch.40 Eddy Flow Fire-Flo DN65 Metric Pipe - 1270 1790 2200 2450 5.65 7.96 9.79 10.90 Sch. 10 Mega-Flow Sch. 40 Eddy Flow (DN8O) Metric Pipe Fire-Flo Sch. 10 Mega-Flow 1020 1450 1770 1980 Sch.40 Eddy Flow 4.54 645 787 (ON1 00) 881 Metric Pipe Fire-Flo Sch. 10 - (DN125) Sch.40 Metric 860 1220 1490 1650 DN1 50 Metric Pipe - 3.83 543 6.63 7.38 Sch.10 6 Sch.40 Mega-Flow DN200 Metric Pipe - 540 770 950 1060 0.188 Wall - 2.40 3.43 4.23 8 4,72 Sch.40 Brace Angles are determined from Vertical.. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. See table below for FM listed specialty pipes & FM Listed metric service pipes. Load Ratings reflect 1" (DN25) -2" (DN50) brace members. See table below for listed brace members. Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.52.3, multiply load ratings by a factor of 0.68. 5) To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. ASC Engineered Solutions asc-es.com Building connections that Last- SS-04.21 page 5 SS-SUB-AF035-v03 20220408 W M, m M~~ AE N Model K Lateral Sway Brace Fig. AF035 1 Place the AF035 over the service pipe to be braced. 2 Insert the brace member through the cast hoop ends. The end of the brace pipe shall extend at least 1" (25.4 mm) past the cast hoop ends. 3 Hand tighten the set screws until they contact the brace member. Continue to torque the set screws until the heads bottom out on the cast hoop ends. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the specified range. Notes: The brace member may be installed above or below the service pipe. Asc Engineered Solutions Q I Set Screw InstaLLation 1' Mm. FIG. AF035 cULus Listed & FM Approved Brace Members Brace Member Brace Size Standard (or Equivalent) UL FM Sch. 40 NPS Pipe 1'1'/4, 1Y22' ASTMA53,A106.A135,orA795 I I KSS3552 I I Sch. 40 Metric Pipe EN10255H V GB/I 3091 1 Metric Pipe JIS 03454 FIG. AF035 WILLIS Listed & FM Approved Metric Service Pipes Service Pipe Standard (or Equivalent) Service Pipe Size UL FM KSD3507 KSD3537 0N25 KSD3562 0N32 I I Sch.40 0N40 GB/13091 DNSO GB/T 3092 DN65 JIS 03452 DN80 1 DN100 EN 10255M 0N125 DN150 EN 10255H DN200 I Notes: ASC Engineered SolutionslM brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uLcom and updated FM approval information may be viewed at www.approvatguide.com. Disclaimer: ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC be liable for any incidental, direct, consequential, special or indirect damages or Lost profits where non-ASC bracing components have been, or are used. Seis BraceO Seismic Fire Protection Design TooL may be accessed at www.seisbrace.com SS-04.21 page 6 t1EI asc-es.com BuiLding connections that Last' SS-SUB-AF035-v03 20220408 Universal Swivel Attachment Fig. AF700 c®us <fm USTED APPROVED LBj.acs ASC Engineered Solutions FIG. AF700 Dimensions and Weight A B C D L X Y Weight In/mm In/mm - 1n/mm In/mm In/mm In/mm In/mm Ibs/kgs 1.40 1.983 1.400 1.280 6.40 2.80 1.91 2.25 35.56 50.37 35.56 32.51 162.6 71.1 48.5 1.02 Notes: ASC Engineered Solutions" brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uLcom and updated FM approval information may be viewed at www.approvalguide.com. Service A seismic swivel attachment designed to connect a brace member to the building structure or to a seismic structural attachment. The AF700 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Approvals cULus Listed (ANSI/UL 203a)), FM Approved (FM 1950-13), & FM Tested (FM 1950-16). FM Tested (ANSI/FM 1950-16). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing requirements. Features The set screw provides a visual indication that proper installation has been achieved Eliminates brace member eccentricity by concentrically loading land 11/4" brace pipes Ordering Specify figure number, fastener size, finish and description. Disclaimer: ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-ASC bracing components have been, or are used. Seis Braces Seismic Fire Protection Design Toot may be accessed at www.seisbrace.com AFCON. An ASC Engineered Solution Material Specifications Size Range Brace Member: See Table Anchors: 1/2_ 1/4" (M12—M18) Material Ductile Iron with Carbon Steel Hardware Finish El Plain 0 Electro-Galvanized per ASTM B633 PROJECT INFORMATION . . APPROVAl. STAMP Project: P Approved - Address: U Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal, Date: Notes 1: Notes 2: SS-05.21 page 1 SS-SUB-AF700-v02 20220408 NFPA 13 Orientations A, B, or C NFPA 13 Orientations D, E, or F NFPA 13 Orientations G, H, or I Ism 'Ax. Engineered Solutions Universal Swivel Attachment Fig. AF700 FIG. AF700 cULus Listing per ANSI/UL 203a (ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle 30°- 44° 45°- 59" 60°- 90' Listed 1° - 2" 14'- V 942 lbf 1333 Ibf 1632 lbf 1885 lbf Sch 40 Pipe (M12-M18) (4.19 kN) (5.93 kN) (7.26 kN) (8.38 kN) (DN25 - DN50) Load ratings may apply to NPFA 13 fastener orientations A, B, C, 0, E, F, G, H, or I. Brace Angles are determined from Vertical. Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3 See table below for listed brace members. Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. FIG. AF700 FM Approved (Listing) per FM 1950-13 (ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle 30°-44° 45°-59° 60°-74° 74'-90' Sch 4OP 1780 lbf 2510 lbf 3080 lbf 3440 lbf (0N25 - 0N50) (M12-M18) (7.92 kN) (11.17 kN) (13.70 kN) (15.30 kN) Load ratings may apply to NPFA 13 fastener orientations A, B, C, 0, E, F, C, H, or I. Brace Angles are determined from VerticaL Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table below for listed brace members. Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.52.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply load ratings by a factor of 0.68. To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. - FIG. AF700 FM Listed, Approved & Tested Brace Members - Brace Member Brace Size Standard (or Equivalent) UL FM Sch. 40 NPS Pipe 1', 11/4 , 1W, 2' ASTM A53, A106,A135, or A795 1' DN5 KSS3562 Sch. 40 Metric Pipe DN32 EN10255H DN40 GB/T 3091 Metric Pipe DN50 JIS G3454 1' FIG AF700 Horizontal Prying Factors (Pr) Per NFPA 13: Angles (Deg) Fastener Orientation A B C D E F G H I Brace Angle 30'-44' 45'.59' 60°-90' 30'-44' 45'.59' 60'-90° 30"44' 45'-59' 60'-90° AF700 2.55 1.09 0.91 1.41 1.45 200 1.83 1.29 1.06 AF700 W/ Metal Deck' 2.55 1.09 1.14 - - - - - - AF700 W/ Metal Deck 2.75 1.11 1.14 - - - - - - Prying factors reflect the baseplate "B" dimension overhanging the edge of the metal deck. Used for DeValt anchor loads. Prying factors reflect the baseplate "A" or 'B' dimension overhanging the edge of the metal deck. Used for NFPA & Hilti anchor loads. Prying Factors calculated in accordance with NFPA 13-2019 Section A.18.5.12.2. asc-es.com Building connections that Last- SS-05.21 page 2 SS-SUB-AF700-V02 20220408 FiThi:cs ASC Engineered Solutions Universal Swivel Attachment Fig. AF700 Method 1 - Connection to Brace Member First 1 Slide the brace member over the lower jaw until it contacts the back wall. 2 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly up to the fastener or the related seismic structural attachment and connect through the mounting hole. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the range specified. Notes; The cross bolt should be hand tight. For visual inspection, at least one thread should be exposed. Method 2 - Connection to Structure First 1 Connect the AF700 to the fastener or the related seismic structural attachment. 2 Tighten per the fastener or structural attachment specifications. 3 Slide the brace member over the lower jaw until it contacts the back watt. 4 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. 5 Rotate the brace member until the brace angLe is within the specified range. Notes: The cross bolt should be hand tight. For visual inspection, at Least one thread should be exposed.. Structural Attachments, Anchors, & Fasteners Listed, Approved, & Tested with the AF700 Structural Attachment Structure AF085 Steel Joist (Top Chord) AF086 Horizontal Steel Flange (I-Beam Bottom Flange) AF772 Horizontal Steel Flange (I-Beam Bottom Flange) Horizontal Steel Flange (I-Beam Top or Bottom Flange) AF778 C-Channel (Top or Bottom Flange) Vertical Flange of a Joist (Top Chord) AF779 All Structures with the Applicable Approved Anchor or Fastener DeWalt Cracked Concrete Power-Stud5+ SO1 Cracked Concrete Filled Metal Deck DeWalt Cracked Concrete Power-Stud5+ SD2 Cracked Concrete Filled Metal Deck DeWalt Wood-Knocker®ll+Concrete Cracked C DeWalt Bang-lt®+ Cracked Concrete Filled Metal Deck DeWalt DDI+" Cracked Concrete Filled Metal Deck - - Cracked Concrete Anchors & Fasteners Cracked Concrete Filled Metal Deck Steel asc-es.com Per NFPA 13 Wood Saw Lumber or Glue-Laminated Timbers Building connections that Last- SS-05.21 page 3 SS-SUB-AF700-v02 20220408 Longitudinal & Lateral Seismic Clamp Fig. AF730 FIG. AF730 Dimensions and Weight Size A B V In/mm In/mm - In/mm 1" (0N25) 7.6 193 1W (DN32) 8.0 203 11/2 (DN40) 8.2 208 (DN5O) 8.7 221 2W 9.2 234 (DN8O) 9.8 249 1.50 381 1.91 48.5 4" (DN100) 10.8 274 12.1 307 13.2 335 8" 15.2 386 10' 18.1 460 12' 20.1 511 Weight lbs/kg 2.49113 2.55 1.13 2.64 1.20 2.78 1.26 2.9? 1.32 3.13 1.42 3.38 1.53 3.81 1.73 4.12 1.87 6.40 2.90 7.60 3.45 8.60 3.90 J91iii ti .. 9.JASC. 1~k';;iIIO Engineered Solutions Material. Specifications Size Range Service Pipe Size: 1" - 12, DN25-DN100 Material Carbon Steel Clamp and Hardware. Ductile Iron Brace Member Attachment Fitting. Finish L Plain E Clamp: Hot Dipped Galvanized per ASTM A153 El Brace Member Attachment Fitting: Electro-Galvanized per ASTM B633 Service A seismic longitudinal and Lateral brace clamp designed to connect a piping system to a brace member. The AF730 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Approvals cULus Listed (ANSI/UL 203a) and FM Approved (FM 1950-13). FM Tested (ANSI/FM 1950-16). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing requirements. Features Torque offset screw and nuts provide a visual indication that the desired installation torque values have been achieved. Ordering Specify figure number, service pipe size, finish, and description. Disclaimer: ASC Engineered Solutions does not provide any warranties and specifically disclaims any Liability whatsoever with respect to ASC bracing products and components that are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-ASC bracing components have been, or are used. Seis Braces Seismic Fire Protection Design Toot may be accessed at www.seisbrace.com Notes: ASC Engineered Solutions'" brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL Listing information may be viewed at www.uLcom and updated FM approval information may be viewed at www.approvalguide.com. AFCON. An ASC Engineered Solution PROJECT INFORMATION . APPROVAL STAMP Project: DApproved - Address: 0 Approved as noted Contractor: El fl Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 Longitudinal Application Lateral Application Riser Application Engineered Sol.utions Longitudinal & Lateral Seismic Clamp Fig. AF730 FIG. AF730 cULus Listing per ANSI/UL 203a (ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service Size Pipe Pipe 30-44 45-59 60-90 Listed 30-44 45-59 60-90 Listed Ibf/kN IbfIkN Ibf/kN ibflkN Ibf/kN thf/kN IbfIkN Ibf/kN Sch 10 Mega-Thread 1 Sch 40 MLT/GL 340 480 588 680 340 480 588 (0N25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 EZ-Thread Mega-Flow Sch 10 MLT/GL 11/4 Sch. 40 Mega-Thread (0N32) Metric Pipe Eddy Flow Eddy Thread EZ-Thread Mega-Flow MLT/GL 11'2 Sch. 10 Sch. 40 Mega-Thread Eddy Flow 375 530 649 750 375 530 649 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2 Sch. 10 Mega-Thread (DN5O) Sch. 40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo EZ-Thread MegFlow - 25 Sch. 10 Eddy Flow Sch. 40 Fire-Flo 545 770 943 1090 545 770 943 Sch. 10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 419 (DN8O) Sch. 40 Eddy Flow Metric Pipe Fire-Flo Sch. 10 Mega-Flow (DN1 00) Sch. 40 Eddy Flow Metric Pipe Fire-Flo Sch.10 - Sch.40 6 Sch .10 M Fl 942 1333 1632 1885 942 1333 1632 1885 Sch. 40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 716 8.38 Sch. 10 8 0.188 Wall - Sch. 40 101, 0.188 Wall - Sch. 40 Brace Angles are determined from Vertical. Sch. 10 & 0.188 Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Listed toad ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes & UL Listed metric service pipes. See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. All load ratings may be used for NFPA 13-2016 designs. 680 3.02 750 3.34 1090 4.85 asc-es.com Building connections that Last- SS-0720 page 2 SS-SUB-AF730-v04 20221228 Longitudinal Application Lateral AppLication Riser Application IN EJ asc-es.com Building connections that last- Engineered Solutions Longitudinal. & Lateral Seismic Clamp Fig. AF730 FIG. AF730 FM Approved (Listing) per FM 1950-13 (ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service Size Pipe Pipe 30-44* 45-59 60-74 75-90 30-44 45-59 60-74* 75-90 lbf/kN Ibf/kN lbf/kN lbf/kN IbfIkN lbf/kN lbf/kN lbf/kN Sch. 10 Mega-Thread Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 774 10.94 13.39 14.95 EZ-Thread Mega-Flow Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (0N32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread EZ-Thread Mega-Flow Sch 10 MLT/GL Sch.40 Mega-Thread Eddy Flow 800 650 790 1800 1790 2530 3100 3460 (DN40) Metric Pipe Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch 10 MLT/GL Sch.40 Mega-Thread Eddy Flow 830 990 1190 1620 1820 2580 3160 3530 (DN50) Metric Pipe Eddy Thread 3.69 4.4 5.29 7.21 81 11.48 14.06 15.7 Fire-Flo EZ-Thread 2Y2 Sch. 10 Mega-Flow Eddy Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 1014 12.41 13.88 Sch. 10 Sch.40 Mega-Flow Eddy Flow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 T56 6.89 9.79 11.97 13.39 'h 10 A - In ' ' 4" ..... " 760 1040 1270 1400 1260 1790 2190 2440 Sch.(DN100) Metric Pipe Eddy Fw 3.38 4.63 5.65 6.23 56 7.96 9.74 10.85 Sch. 10 - 890 1230 1410 1550 1260 1790 2190 2440 Sch. 40 3.96 547 6.27 6.89 5.6 7.96 9.74 10.85 6 Sch. 40 Mega-Flow 3.11 4.18 5.07 583 4.23 5.96 7.3 8.14 Sch .10 M Fl 700 940 1140 1310 950 1340 1640 1830 8' 0.188" Wall - 990 1130 1360 1520 1540 2170 2660 2970 Sch. 40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 1321 0.188' Wall - 1020. 850 1000 1100 1700 2410 2950 3290 Sch. 40 4.54 378 4.45 489 7.56 1072 13.12 14.63 12' 0.188'Wall - 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 431 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply load ratings by a factor of 0.68. To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v04 20221228 iifipcq~~- US I 4 Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig. AF730 Method 1 - Connection to Brace Member First 1 Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe. Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 3 Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. FIG. AF730 cULus Listed & FM Approved Brace Members Brace Member Sizes Standards (or Equivalent) UL Listed FM Approved Sch. 40 NPS Pipe l,l/4,lV22 ASTM A53, Al 06, Al 35, or Sch. 40 Metric Pipe KS 03562 / / 0N25, 0N32, EN10255H / Metric Pipe DN40, 0N50 GB/T 3091 / JIS 03454 / FIG. AF730 cULus Listed & FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS03507 / / KS 0 3537 KS03562 / / Sch. 40 GB/I 3091 / GB/I 3092 DN25DN32DN40, . 0N50, ON 80, DN100 J1SG3452 EN 10255M asc-es.com EN 10255H Building connections that last- SS-07.20 page 4 SS-SUB-AF730-44 20221228 Size Range: Flange Thickness: 1/8" to 3/4" thick Material Ductile Iron Casting with Carbon Steel Hardware Finish O Plain 0 Electro-Galvanized per ASTM B633 Service A seismic structural attachment designed to attach to steel I-beams, flanges, and joists. The AF778 rigidly braces piping systems subjected to horizontal and vertical seismic loads. 9 j ApprovaLs cULus Listed (ANSI/UL 203a), FM Approved (FM W 1950-13), & OSHPD (OPM-0351-13). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing requirements. /2 Mounting Bolt Engineered Solutions Universal Structural Brace Attachment Fig. AF778 Material Specifications osbpd c@us <3 > OPM-0351-13 LISTED APPROVED FIG. AF778 Dimensions and Weight A B L W H Weight Mounting Bolt In/mm In/mm In./mm In/mm In/mm lbs/kg yu 0.75 0.75 4.13 2.75 2.25 2.26 (M12) 19.1 19.1 104.8 69.9 57.2 1.03 Off Bolt x2 Features The set screw provides a visual indication that proper installation has been achieved May be installed anywhere a Fig 92 standard throat beam clamp may be installed Ordering Specify figure number, finish, and description. InstaLLation 1 Place the AF778 on a horizontal or vertical steel flange 2 Hand tighten the set screws until they contact the flange. Continue to torque the set screws until the heads break off. 3 Mount the AF700, AF771, or AF076 to the ½' mounting bolt. The mounting bolt shall be installed wrench tight (typically finger tight plus 1/4 to ½ turns). Notes: When installed with the AF700, AF771, or AF076, the lowest load rating at angle shall control the load rating of the assembly. . AFCON. An ASC Engineered SoLution PROJECT INFORMATION . APPROVAL STAMP Project: 0 Approved Address: 0 Approved as noted Contractor: fl Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: 55-05.21 page 1 SS-SUB-AF778-02 20220304 Horizontal Steel Flange Seismic Load Parallel to Flange Horizontal Steel Flange Seismic Load Perpendicular to Flange Vertical Steel Flange Seismic Load Parallel to Flange Vertical Steel Flange Seismic Load Perpendicular to Flange 0 NT Universal Structural Brace Attachment Fig. AF778 FIG. AF778 cULus Listing per ANSI/UL 203a (ASD) Structure Load Orientation Flange Thickness Horizontal Load Rating at Brace Angle 30'-44' 45'-59 60-90 Listed Horizontal Steel Flange and Parallel to Flange 0.1875 - 0.750 in 800 lbf 1131 lbf 1385 lbf 1600 lbf Vertical Steel Flange Perpendicular to Flange (4.76- 19.05 mm) (3.56 kN) (5.03 kN) (6.16 kN) (7.12 kN) Listed for installation with Fig. AF700, AF'TTI, and AF076 Brace Angles are determined from Vertical. Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5,2.3. FIG. AF778 cULus Listing per UL 203a (ASD) for NFPA 13-2016 Editions or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 13. The 2016 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition. The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 2034, Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping; based upon a minimum safety factor of 1.5 in accordance with the earlier editions of NFPA 13. The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority Having Jurisdiction (AHJ). Structure Load Orientation Flange Thickness Horizontal Load Rating at Brace Angle 30'-44' 45-59 60-90' Listed 0.1875 - 0.249 in 500 Ibf 707 lbf 865 lbf 1000 lbf (4.76 - 6.32 mm) (2.22 kN) (3.15 kN) (3.85 kN) (4.45 kN) Horizontal Steel Flange and Parallel to Flan9e 0.250- 0.499 in 800 lbf 1131 lbf 1385 lbf 1600 lbf Vertical Steel Flange Perpendicular to Flange (635-12.67 mm) (3.56 kN) (5.03 kN) (6,16 kN) (7.12 kN) 0.500 - 0.750 in 1007 lbf 1425 lbf 1744 lbf 2015 lbf (12.70- 19.05 mm) (4.48 kN) (634 kN) (7.76 kN) (8.96 kN) 1) Listed for installation with Fig. AF700 & AF771 2) Brace Angles are determined from VerticaL 3) Listed toad ratings reduced for angle ranges in accordance with NFPA 13-2016 Table 9.3.5.2.3. 41 Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.23. FIG. AF778 FM Approved (Listing) per FM 1950-13 (ASD) Structure Load Orientation Flange Thickness Horizontal Load Rating at Brace Angle 30'-44° 45'-59 60-74° 75--9Y- Parallel lbf 1440 lbf 1230 lbf 1360 lbf Parallel to Flange (3.87 kN) (6.14 kN) (5.47 kN) (6.05 kN) Horizontal Steel Flange 1030 lbf 2260 lbf 2490 lbf 2750 lbf Perpendicular to Flange 0.125 - 0.750 in (458 kN) (10.05 kN) (11.08 kN) (12.23 kN) (3.18- 19.05 mm) 1280 lbf 1840 lbf 2210 lbf 2470 lbf Parallel to Flange (5.69 kN) (8.18 kN) (9.83 kN) (10.99 kN) Vertical Steel Flange 15701b1 14901bf 1040lbf 1150 lbf Perpendicular to Flange (6.98 kN) (6.63 kN) (4.63 kN) (5.12.kN) Listed for installation with Fig. AF700 & AF771 Brace Angles are determined from VerticaL 31 Listed toad ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply toad ratings by a factor of 0.68. 5) To convert to LRFD Load Ratings, ASD Load Ratings may be muttipted by a factor of 1.5 Notes: ASC Engineered Solutionsw brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL Listing information may be viewed at www.uLcom and updated FM approval information may be viewed at www.approvalguide.com. Disclaimer: ASC Engineered SoLutionsm does not provide any warranties and specifically disclaims any Uability whatsoever with respect to ASC bracing products and components that are used in combination with products, parts or systems not manufactured or sold by ASC. In no event shall ASC be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-ASC bracing components have been, or are used. Seis Brace Seismic Fire Protection Design Toot may be accessed at www.seisbrace.com 1ASC Engineered Solutions III asc-es.com Building connections that Last- SS-03.22 page 2 SS-SUB-AF778-v02 20220304 4. BACKFLOW DEVICE. Features Sizes: 2 1/2", 3", 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged bolt pattern) ASME 616.42 Class 150 Model 375DAG SHOWN BELOW L4. ZURN Model 375DA Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and back- pressure of contaminated water into the potable water supply. The Model 375DA shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Unless otherwise noted, applies to sizes 2 1/2" thru 10") ASSE® Listed 1047 UL® Classified AWWA Compliant C550 CSA® Certified B64.4 (4" & 6") C-UL® Classified FM® Approved NYC MEA 218-01-M VOL 3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI/CAN 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4" Model 975XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless steel, 300 series Sensing line Stainless steel, braided hose IT! ,el l.•1l1. 0 ' • . MIMI Options (Suffixes can be combined) O - with OS & V gate valves (standard) U L - less shut-off valves (flanged body connections) O LM - less water meter U - with gpm meter (standard) CFM - with cu ft/min meter El G - with groove end gate valves O FG - with flanged inlet gate connection and grooved outlet gate connection 0 P1 - with Post Indicator Gate Valve U GF - with flanged inlet connection and grooved outlet connection U BIG - with grooved end butterfly valves with integral monitor switches (2 1/2" - 10") Accessories 0 Air gap (Model AG) O Repair kit (rubber only) 0 Thermal expansion tank (Model XT) 05 & Y Gate valve tamper switch (OSY-40) OT-SET Quick Test Fitting Set Attention: Relief Valve discharge Model 3750A (flange body) and port: Model 375ADA 2 1/2" - 6" - 2.75 sq. in. (grooved body) have different lay lengths. 8'- 10" -3.69 sq. in. A A Dimensions & Weights (do not include pkg.) DIMENSION (approximate) WEIGHT MODEL 375DA SIZE in. mm A in. I mm A WITH BUTTERFLY VALVES in. I mm B LESS GATE VALVES in. I mm in. imm D in. imm E os&v OPEN in. I mm E oS&v CLOSED in. mm E WITH BUTTERFLY VALVES in. I mm in. I mm G in. Immibs. LESS SHUT- OFF OFF VALVES I kg OS&Y GATE VALVES FLANGED lbs. I kg OS&Y GATE VALVES GROOVE) ibs. I kg BUTTERFLY VALVES GROOVED ibs. I kg 21/2 65 31 787 28 711 157/81403 71/4 184 9 1229 173/4 451 153/8 391 133/4 349 91/2 241 83/8 1213 75 34 185 1 84 167 76 147 1 67 3 80 32 813 281/2 724 157/81403 71/4 184 9 229 201/4 514 17 432 133/4 349 91/2 241 83/8 213 78 35 208 94 160 73 130 59 4 100 375/8 956 328/9 835 9 203 9 229 221/2 572 181/4 464 17 432 11 279 91/4 235 116 53 306 139 292 132 200 91 6 150 443/8 1133 375/8 956 231/2 10 254 101/2 267 301/2 775 241/4 616 171/2 445 123/8 314 91/4 235 194 88 494 224 468 212 312 142 8 200 607/8 1546 537/8 1369 191/2k495 373/4 11 279 161/2 394 37 940 281/2 724 1615/16 430 153/8 391 16 3/4 426 382 173 858 389 810 367 556 252 10 250 637/8 1622 577/8 1470 373/4 11 279 151/2 394 455/8 1159 343/4 883 1615/16 430 153/8 391 163/4 426 412 187 1230 558 1164 528 800 363 Zurn Industries, LLC I Wilkins Rev.P Date: 08/20 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Document No BF-375DA In Canada I Zurn Industries Limited Product No Model 375DA 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 Patent zurn.com/patents www.zurn.com Page l of 2 w 15 [I 800 Flow Characteristics ORated Flow (established by approval agencies) MODEL 375DA 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (IIs) 0.0 12.6 25.2 37.9 C, U) ICU CL IL 0 200 400 600 FLOW RATES (GPM) MODEL 375DA 6", 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 IL 15 020 IX IL 0 1000 2000 3000 FLOW RATES (GPM) 252.4 138 0(250mm) —I 103 u) j U) 0 69 —' = w - 34 = Cl) - w 0a 4000 °- Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. PROTECTIVE OUTDOOR INSTALLATION Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/2' 75 112 149 224 3' 115 173 230 346 4" 198 298 397 595 6' 450 675 900 1351 8' 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 INDOOR INSTALLATION Specifications The Reduced Pressure Detector Backflow Prevention Assembly shall be certified to NSF/ANSI/CAN 61 ASSE® Listed 1047, and supplied with full port OS & V gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elas- tomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 375DA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2