7201 RANCHO SANTA FE RD; ; FPC2023-0058; Permit
4ity of PERdXT REPORT Carlsbad Print Date: 04/24/2025 Permit No: FPC2023-0058 Job Address: 7201 RANCHO SANTA FE RD, CARLSBAD, CA 92009-8686 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2236172400 Track #: Applied: 03/23/2023 Valuation: $0.00 Lot #: Issued: 04/27/2023 Occupancy Group: Project #: Finaled Close Out: 11/01/2023 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: CARLSBAD FIRE STATION NO. 6 -ADD A SMOKE DETECTOR & A CELL DIALER TO AN EXISTING SPRINKLER MONITORING SYSTEr Applicant: FPContractor: STANDARD ELECTRONICS ACCENT ELECTRONICS JESUS LEDEZMA 613 W MAIN ST 9340 STEVENS RD EL CAJON, CA 92020-3323 SANTEE, CA 92071-2810 (619) 596-9950 (619) 596-9950 FEE AMOUNT FIRE Sprinkler Monitoring $453.00 Total Fees: $453.00 Total Payments To Date: $453.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Pk (619) 596-9950 February 28, 2023 Fax: (619) 596-8850 613W. Main St. I'rfl El Cajon, CA 92020 C7, do tiC. #590876 Electronics BSISACO #AC01903 UL Installer #S3570-1 StandardElecfronics.us SUBMITTAL SHEET PROJECT: Carlsbad FS #6 Rm 106 Split T.I. - 3090 ELEC.CONTR: EQUIPMENT Sprinkler Monitoring ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 1 IntelliKnight Addressable Photoelectric Smoke Detector SFM# 7272-0559:0178 SD505-PHOTO Silent Knight 2 1 Smoke Detector Base, 6" SFM# 7272-0559:0178 SD505-6AB Silent Knight 3 1 Network/Cellular Communicator DualComNF-LV DMP 4 1 High Gain Antenna 388-3 DMP 5 1 Antenna Cable 387-4 DMP 6 0.3K 2 conductor, 16 AWG, Unshielded, Plenum Jacketed 162FP WCW SILENT Addressable Photoelectric KNIGHT Smoke Detector by Honeywell Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The lntelliKriight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO approximately every 15 seconds, Analog I Addressable indicating that the head is Photoelectric Type Smoke communicating with the loop. The 10 Detector LED lights continuously during the I 6a 41b The 5D505-PHOTO is particularly alarm period. r4tAAha___j_.777~ -.9A suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The 5D505-PHOTO units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks Features Low profile, 2 inches, includh base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved Specifications Operating Voltage: 24-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA SD505-PHOTO Smoke Detector Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% non- condensing Air Velocity: 0 - 300 FPM Compatible Bases: 50505-6AB (Sold Separately) 5D505-61B 5D505-6RB 5D505-6SB P/N 350225 Rev G © 2015 Honeywell International Inc. Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight 5D505-PHOTO. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight 5D505-HEAT Heat Detector. Base shall be the appropriate twist-lock base 5D505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The 5D505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15/16' Diameter = 3-15/16" '4 Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505.PHOTO Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0178 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECUl4ne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (ø) 484-6105 Fax (203) 484-7309 Email: lisa.branti(oneywell.com DESIGN: Model 5D505-PHOTO analog, photoelectric smoke detector for use with Model 5D505-6AB base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 17.0 -39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as an analog photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0410:0204 10-22-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division a) -a- . (a 0) co CL- - = E - = . (0 - . cm ro ra - = L - £ £5 5 E ro r0 - - -F - o Cl cl - _ (0 - E cu 12 cD £ £ £ S £ LIJ E W a) WORKS WITH MOST PANELS If the existing panel supports Contact ID, its a candidate for upgrading with Corn Series communicators. There are no issues with lockout codes. Simply add the Corn Series unit to the existing installation and program in your own account number. UPGRADING HONEYWELL VISTA PANELS Corn Series communicators can be programmed to easily take over Honeywell VISTA panels. The communicator connects to a VISTA Series ECP bus, which will allow you to program the Honeywell panel remotely using Compass. UPGRADE DSC POWERSERIES PANELS Connect to the PowerSeries panel through the Corn Series communicators to remotely manage all user codes and easily check zone status from the Virtual Keypad app. USER CODE MANAGEMENT With Virtual Keypad, your customers can eliminate time and money spent managing user codes - this is especially meaningful with multiple sites. At onetime, they can send a user code to multiple panels. Each of those panels can be different - whether they're XR, XT or Com Series. AVAILABLE BURGLARY COMMUNICATION The DualComWZ provides control of basic panel security functions and video. It adds the ability to remotely interact with Z-Wave devices, enabling automation features including control of lights, door locks, thermostats and more. FIRE COMMUNICATION The CellComF-LTE provides cellular fire communication and the DualComNF offers both network and cellular fire communication. Either one works on any fire control panel via Contact ID capture. Both meet NFPA 72 standard for single communication technology. FIRE PANEL TAKEOVER DuaICornNF and CeIlComF-LTE provide two tip and ring to easily take over existing fire panels with two phone lines. FIRE PACKAGE The PowerComF allows you to add new communication technologies to an existing fire panel. Included in the pre- assembled package are: One AT&T or Verizon DualcomNF One 505-12 Power Supply The communicator has all the power it needs without drawing from the panel. This alleviates the need to perform any battery calculations for the existing fire panel. MOBILE SYSTEM CONTROL With all Corn Series communicators, you can easily update your customers' older residential and commercial systems to the latest cellular communication. With cellular in place, users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile devices to control basic arm/disarm functions and receive alerts. "EX" STANDS FOR EXPRESS The CelIComEX Universal Communicator offers the same feature-rich benefits as CelICom modules but has one zone, one output and one tip and ring terminal, making it extremely quick to deploy with minimal programming or setup steps. Upgrading legacy panels is not only faster but also more affordable. Plus, its compact enclosure is ideal for tight installations. The zone on the CelIComEX provides connection to burglary control panel outputs. It can also be used for the connection to the control panel bell output. FOUR ZONES All other Corn Series models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. - Virtual Keypad App Version Features Arm and Disarm S Notifications (Alarms, Open/Close, Trouble) S View History View Zone Status Manage User Codes Activity Reports Configure Real-Time Notifications SMS or Email Geofencing Video Doorbell SecureCom NVR SecureCom Video Video Integration Central Station Video Verification COM SERIES DUAL-PATH COMMUNICATION MODULE PROGRAMMING FIRSTNET READY® COMMUNICATOR The Corn Series' DualCom modules Programming over network or cell For alarm companies who choose to provide dual-path monitoring center via Dealer Admin" or Remote Link give customers the advantages of Band communication for any burglary, includes zone information and 14 for all of their commercial fire and commercial fire or residential fire panel. As monitoring center communications, non-fire alarm communication. FirstNet indicated in the chart below, each DualCom is built with AT&T in a public-private module integrates hardwired network or MULTIPLE CONNECTION OPTIONS partnership with the First Responder Wi-Fi as primary and secondary cellular Communicators can be attached to Network Authority, and Band 14 is communication on one PCB. the existing panel in a variety of ways. FirstNet's nationwide, high-quality Capture Contact ID messages from the spectrum. Qualified alarm companies FULLY SUPERVISED COMMUNICATION dialer or connect an output from the must obtain a TMA Certificate of The Corn Series allows alarm messages panel to the zone input. Or it can sense Verification and enter into a FirstNet to be communicated to an SCS-1R the output of the bell of an existing Agreement with AT&T. or SCS-VR Receiver over network or alarm and communicate the appropriate Verizon or AT&T LTE networks. Sending message to the monitoring center. ADD VIRTUAL KEYPAD APP alarm communication for burglary and Enable the Virtual Keypad app on your fire control panels over network or the OUTPUTS customers' existing panels for a minimal LTE network provides higher speeds. Use outputs to connect to an arming additional cost. Brand DMP's Virtual zone of an existing panel for control of Keypad app with your organization's FIELD PANEL UPDATES that panel via the app. logo and contact information to provide The Model 401 USB Flash Module a daily reminder of your services. allows you to conveniently field update EASY UPGRADE FOR DIALER-ONLY PANELS firmware for the communicators that Older dial-up panels have new life with ENABLE VIDEO ON THE APP would otherwise require the use of the addition of network or cellular With the Corn Series communicators, a computer and a Model 399 communication. Earn customer loyalty you can add up to six video cameras. Programming Harness, by extending the life of their existing Via the Virtual Keypad app, users can panels and add modern panel features remotely view their premises to cancel at the same time. or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. Corn Series Features DualComNF-Lv —Verizon • . Red • 2 4 2 DualComNF-LA AT&T • • Red • • • 2 4 2 DuaIComNF-FN AT&T • • Red . • • 2 4 2 DualComW-LV Verizon • White • • • 1 4 2 DualComW-LA AT&T • White • • • 1 4 2 DuaIComWZ-LV Verizon • White • • • 1 4 2 DuaIComWZ-LA AT&T • White • • • 1 4 2 DualComN-LV Verizon • • White • S • 1 4 2 DualComN-LA AT&T • . White • S • 1 4 2 CellCom-LTE-V Verizon • White • • • 1 4 2 CeIIComF-LTE-V Verizon • Red • • • 2 4 2 CeIlComEX-V Verizon • White • • • 1 1 1 CeIIComEX-A AT&T • White • • • 1 1 1 PowerComF-V Verizon • • Red • • • 2 4 2 PowerComF-A AT&T • • Red • • • 2 4 2 COM SERIES Universal Alar Communicator Ordering Jf6rmation DualComNF-LV Fire, Hardwired Network Primary and LIE Backup (Verizon) DualComNF-LA Fire, Hardwired Network Primary and LIE Backup (AI&1) DualComNF-FN Fire, Hardwired Network Primary and LIE Backup (AT&T FirstNet) DualComW-LV Wi-Fi Primary and LIE Backup (Verizon) DualComW-LA Wi-Fl Primary and LIE Backup (AI&1) DualComWl-LV Wi-Fi Network Primary and LTE Backup with i-Wave (Verizon) DualComWZ-LA Wi-Fl Network Primary and LIE Backup with i-Wave (AT&1) DualComN-LV Hardwired Network Primary and LIE Backup (Verizon) DualComN-LA Hardwired Network Primary and LIE Backup (AT&1) CellCom-LIE-V LIE (Verizon) CellComF-LIE-V LIE (Verizon) PowerComF-V Fire, Hardwired Network Primary, LIE Backup (Verizon), Power Supply PowerComF-A Fire, Hardwired Network Primary, LIE Backup (AI&1), Power Supply CellComEX-V LIE (Verizon) CellComEX-A LIE (AI&1) Accessories 381-2 18" Coax Extension 381-12 1' Coax Extension 381-25 25' Coax Extension 383 Cellular Antenna 386 Wall Mount Antenna Bracket 387-2 2dB Attack Enclosure Antenna 381-4 4' SMA to N Extension Cable 381-8 8' SMA to N Extension Cable 381-25 SMA TON CABLE, 25F1, LMR195 381-50 SMA TO N CABLE, 5OFL LMR195 388-1 3dB Fiberglass Antenna w/bracket 388-2 2 dB Attack Enclosure Antenna 388-3 3dB MEG Antenna 685-R Surface Mount Conduit Backbox (Red) 685-W Surface Mount Conduit Backbox (White) DualCom-HSG-W/10 Replacement Housing Specifications CeliCornEX Dimensions 4.5W x 2.15" H x 1.15" D Open-Collector Outputs 1 Zones 1 Color White Primary Power Nominal 12 VDC Current Draw at 12VDC Alarm 131.5 mA Cell Communication Standby 88 mA NI Other Corn Sees Dimensions 5.5" W 3.15" H xl' D Open-Collector Outputs 2 Zones 4 Color Red DualComNF, CellComF-LTE-V White DualComW, DualComWZ, DualComN, CellCom-LIE-V CellCorn-LTE-V Primary Power 12 VDC Current Draw Alarm 102 mA Standby 55 mA CellCornF-LTE-V Primary Power 12-24 VDC Current Draw at 12VDC Alarm 102 mA Standby 56 mA Current Draw at 24VDC Alarm 82 mA Standby 30 mA DualCom Series Primary Power Nominal 12 VDC or 24 VDC Current Draw at 12 VDC Alarm 109 mA Standby 64 mA Current Draw at 24 VDC Alarm 82 mA Standby 30 mA PowerCorn Series Primary Power Nominal 12 VDC Current Draw at 12 VDC Alarm 109 mA Peak Cellular Communication Standby 64 mA Certifications For additional information, go to DMP.com/Compliance. 800-641-4282 I DMP.com I 2500 N. Partnership Bind, Springfield, NO 65803 I Designed, engineered & manufactured In Springfield, NO using U.S. & global components. UNITED WARRANTY: BlIP warrants that the products manufactured by BlIP shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to BlIP for inspection. To read the full DMP Limited Warranty, go to OMP.com/Warranty or check the BlIP Price List or Catalog. Any third-party trademarks referenced herein are the property of their respective owners and do not Indicate or Imply any affiliation, sponsorship or endorsement of BlIP or Its products. © 2022 Digital Monitoring Products, Inc. I LT-2428 122325 Fire/Life Safety SmartWireTM UL Listed and Rated Type CMP or FPLP Multi-Conductor Non-Shielded Plenum Fire Alarm 162FP - 16 AWG 2 Conductor Non-Shielded Plenum Fire Alarm Description - - .I6 AWG 2 Conductorl Bare Copper, Non- Shielded Plenum Fire Alarm, UL C(UL) CMP1 - or FPLP UL rConductor Description 16 (Solid Bare - L.Copper) -- tnsulation 'tow-Smoke PVC I .o10" jColor Code - - --black/Red Jacket __.... ------------ Low-Smoke PVC Marking TiAT1 CONTROL CABLE INIT. / IND. DEVICE !, ZONE A B CD E 0 1 12 34 567 89 16 AWG UL C(UL) CMP - :OR FPLP UL ROHS - - - :MADE IN THE USA Overall Diameter - - - -- ' " Nom 'Capacitance 26 pF/FLNom Temperature and 0 C to 75 C I Voltage Rating 300 Volt Cable Weight 26 Lbs/Mft. Flame Rating: Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test Agencies Approvals: NEC Article 800, 760; UL C(UL) CMP or FPLP UL, RoHS Compliant, Made in the USA C®