Loading...
HomeMy WebLinkAbout5925 PRIESTLY DR; 110; FPC2020-0076; PermitPERXT REPORT cJity of Carlsbad Print Date: 04/24/2025 Permit No: FPC2020-0076 Job Address: 5925 PRIESTLY DR, # 110, CARLSBAD, CA 92008-8844 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4: 2120610800 Track : Applied: 04/20/2020 Valuation: $8,836.90 Lot #: Issued: 05/05/2020 Occupancy Group: Project #: Finaled Close Out: 01/27/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check#: Project Title: Description: ARGONAUT - MONITOR 4 DUCT DETECTORS Applicant: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Submittal Package for: Argonaut 5925 Priestly Drive Vel/0 Carlsbad, CA 92008 River Fire and Security 8920 Activity Road, Suite J San Diego, CA 92126 Contains Cutsheets and CSFM Listings for: EXISTING Fire Alarm Control Panel EXISTING Cellular Communicator EXISTING Document Cabinet Input Module EXISTING Smoke Detector IFP-75B Honeywell I Farenhyt Series Intelligent Fire Alarm Control Panel FP-75 / IFP-75B The IFP-75 (red) and IFP-75B (black) are intelligent analog! addressable Fire Alarm Control Panels (FACP). IFP-75 has a single line circuit (SLC) Loop for connecting addressable detectors, which can support 75 IDP/SK sensors and 75 IDP/SK modules or 75 SD devices per Loop. For System Sensor devices the overall point capacity to a maximum of 150 points per panel, or for Hochiki devices the overall point capacity to a maximum of 75 points per panel. IFP-75 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system. LFP-75 has a built-in dual-line digital and I communicator with an optional cellular communication module, Form C trouble relay, and two programmable Form C relays FP-75 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-75 supports a variety of devices, including PA- 2000, PA-1000 or PA-bOO remote annunciator, 5824 serial/ parallel printer interface module (for printing system reports), RPS-1000 power module, and LDP, SK or SD devices. FEATURES & BENEFITS Network support for up to 32 Sites Built-in support for up to 75 IDP/SK detectors and 75 IDP/SK modules or 75 SD SLC devices Four tine LCD display with 40 characters per line Available in a red or black cabinet FP-'15 can be surface or flush mounted Built-in USB interface for programming Programmable date setting for Daylight Saving Time JurnpStart Auto Programming feature for easy programming Built-in dual phone line. digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies Network card allows copper network connection with a multi-mode or single-mode fiber connection option Firmware can be upgraded in the field Supports up to four SWIFT wireless gateways. Each gateway can have up to 49 wireless devices Supports Class B (Style 4) and Class A (Style S or Style 7 configuration for SLC. and SBUS Built in synchronization for appliances from AMSECO. Gentex', System Sensor and Wheelock Reports events to central station by point or by zone IFP-75 Technical Specifications SPECIFICATIONS Physical: Overall Dimensions: 15.12 H x 12.71' W 3.330 Weight: 25 lbs. Color: Red or Black Environmental Operating Temperature: 32°F to 120°F (0°Cto49°C) Humidity: 0 t 93% relative humidity (non- condensing) ELECTRICAL: IFP-75 Primary AC: 120 VAC 60 Hz, 900mA Total Accessory Load:2.5A 18 27.4 VDC power-limited Standby Current: 165 mA Alarm Current: 310 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service Other Approvals: UL Listing; CSFM (pending); COA (pending); OSHPD (CA) (pending), FM (pending) APPROVED RELEASING SOLENOIDS Asco T82104107 24VDC 3Amax 0 H Asco 8210G207 24VDC 3Amax 0 H COMPATIBLE DEVICES See the data sheets listed below for a complete Listing of the IDP, SK, SWIFT or SD devices. 350361 - lOP Device Protocol data sheet 53623 - SK Device Protocol data sheet 350360-SD Device Protocol data sheet 351615 & 351617- SWIFT devices ORDERING INFORMATION IFP-75 - Intelligent Fire Alarm Control Panel. Red IFP-75B - Intelligent Fire Alarm Control Panel Black SBUS ACCESSORIES RA-2000, P4-1000, RA-1000R, RA-100, RA-2000GRAY- Remote annunciators. RPS-1000 - Power Supply 5496- NAC Expander 5824- Serial/Parallel Module 5880- LED I/O Module 5865-3/-4 - LED Annunciator 5883- Relay Interface MISCELLANEOUS ACCESSORIES SKSS-3 - Software Suite. Provides programming, upload/download and event reporting RBB - Remote Battery Box Cabinet. Use for backup batteries up to 35 AH. Dim: 16W x 10' H x 6" D SK-SCK - Seismic Compliance Kit SK-NIC - Network Interface Card SK-NIC-KIT- Network Interface Card in Cabinet SK-FML- Multi Mode Fiber Card SK-FSL -Single Mode Fiber Card CELL-MOD - Cellular Communicator in Plastic Enclosure CELL-CAB-SK - Cellular Communicator in Metal Enclosure with lock and key EW For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft. Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. All other trademarks are the property of their respective owners. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Techn ice I Support, Please call 800-446-6444. For more information www.fahyt.com Honeywell 12 Clintonville Road Northford, CT 06472 300-328-0103 www.farenhyt.com nor. 3516051Rev Al 03/17 2017 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0503 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Silent Knight Model IFP-75, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model IFP-75 System Components.- 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 58654 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paratell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10'HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 120VAC, 60HZ, iSA Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV1C operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0503 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DBc From Tyco Security Products Ensure your installations are future-ready, with LTE Due to rapidly-evolving cellular or 1 hour (NFPA72 2013/2016) technologies, 2G/3G network sunsets of the failure, or it can be used as are already on the horizon - with part of a multiple communications some having already been completed. technologies (for example in Now's the time to adopt and adapt. conjunction with a DACT). When Switch to LTE today, to offer used as a back-up provision shall customers long-lasting investment be made to monitor the integrity of protection, and reduce your future each communication path and failure truck rolls. of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The LE401 OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the LE401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. Features That Make a Difference: Uses LTE network for high- speed, reliable and low-cost communications to an lP receiver Automatically switches to 3G (HSPA'HSPA+) if LTE service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via website or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/ll/lll/lV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed The LE401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System I-IP/ll/lll/IV/5). The LE401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The LE401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) From Tyco Security Products In instances where the control panel does not support Contact ID or SIA (300 baud), the LE401 OCF has inputs pre- set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IF linecard of the monitoring station receiver (Sur-Gard® System l-lP/ll/lll/lV/5). Activating & Initializing the Unit Activating and initializing the LE401 OCF can be done using the website interface provided by 024 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The LE401OCF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE401OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE401OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The LE401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: LE401 OCF-AT .............. Universal Wireless Commercial Fire Alarm Communicator Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the LE401 OCF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013/2016) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2"x 10 x3" (290 mm x 254 mm x 75 mm) InputVoltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (0° to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description LIE-i 5ANT 15 ft extension antenna LIE-25AN1 25 ft extension antenna LIE-50ANI 50 ft extension antenna CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0506 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Tyco Safety Products Canada Ltd.3301 Langstaff Rd., Concord, Ontario L4K 4L2 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model LE401OCF LTE interface. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a interface for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. 01-11-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct C. i operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Fire Document Box The FDB is the perfect fit to meet the demanding code requirements today. NFPA 72 10.18.2.1.2.8 states that a cabinet must be "prominently labeled 'FIRE ALARM DOCUMENTS'." An internal galvanized sleeve holds the documents safely and securely. The sleeve is easily removable to allow storage of a 1.5" 3 ring binder or other media. The galvanized sleeve also contains 2 hooks for key rings or thumb drives, a place for several business cards, a cutout for a 1.4 Oz. can of test gas and a slot where a standard CD "jewel" case can be stored. Access to the documents is via a high security lock with a 3/4" barrel. Key Ring Hooks Detector Smoke Standard Features: Overall Dimensions are: 12" Wide x 13.1" High x 2.25" Deep 3/4" barrel lock to secure door Piano Hinged Door w/Notes Sticker Removable document holder can hold 1" of 8.5" x 11" paperwork Powder Coat Red Finish 16 Gauge CRS construction Embossed: Key Ring Hooks Business Card Holder CD Case Slot 1.4 Oz. can of detector smoke Custom screening with your logo I FM fffjw—ww — Business Card Holder installation & Inspection Notes Lock w/ 3/4" barrel CD Jewel Case MOO NEPA Made In U.S.A. ISO 900fle 1 REGISTERED COMPANY V Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2008 ED0447 LT10505 Rev.A Oct. 2010 1/2 No Excuses, Just Solutions! 4PSPACE AGE MW ELECTRONICS, INC. Specifications: The Fire Document Box (FDB) shall be constructed of 16 gauge cold rolled steel (CRS); it shall be painted with a durable red powder coat paint. The front door shall be lettered with the words "FIRE ALARM DOCUMENTS" in White indelible letters 1" in height. The door of the FDB shall be locked with a keyed lock, 3/4" barrel. The cabinet shall contain a 16 gauge galvanized CRS sleeve. This sleeve shall allow for the storage of 1" of paper, test and inspection records, manuals and other important documents. The sleeve shall also facilitate the hanging of key rings and thumb drives (for data storage) along with business cards and space for a CD "jewel" case. The unit shall also contain a 1 .4oz can of smoke detector test gas. Adheared inside the door shall be a "Notes" label for the recording of valuable information such as AHJ approvals, various system codes and the location of hard to find devices. If so desired, the internal sleeve (held in by 2 wing nuts) may be removed and the space used to insert a 1.5" 3 ring binder. NOTES: System Access: System Level Code E52613 LImbo! R., fl FDB DnmSmOffi, .# b.C. 58th,(k.R,S St MAO,!,9 BO.4B8!723 Notes Sticker inside FDB Door Ordering Information: Part # Description Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax SSU00672 FDB Fire Document Box SSU00673 FDB Custom Logo/lock (ask for Form FDI 0498 to order custom box) CKI Replacement 1.4 Oz Test Gas No Excuses, Just Solutions! This document is subject to change without notice, see doc # E00479 for legal disclaimer ED0447 LT10505 Rev.A 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and lFX/D enclosures. Models ACE-1 1, ACE-1 2 and ACE-1 3 *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Honeywell Farenhyt1M Series THE POWER OF CONNECTED Addressable Monitor Module OP-Minimon The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minirnon acts as an interface to contact devices, such as waterflow switches and pull stations. The DP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Installation The I DP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. IDP-MINIMON The IDP-Minimon compatible with the following Farenhyt SeriesFACPs: IFP-2100/IFP-2I00ECS/RFP-2100 FP-2000 / IFP-2000ECS / RPS-2000 IFP-1000 / IFP-I000ECS IFP-300/IFP-300ECS IFP-100 / IFP-100ECS IFP-75 IFP-5O FEATURES & BENEFITS Single contact monitor Small and Lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications ULApproved CSFM Listed ME/\ Listed 457-99-E Vol. V IDP-Minimon Technical Specifications Other Devices Wineg the tDP-Mlnleeon SPECIFICATIONS Physical: 1.3 H x 2.8W x.5" D (3.3 x 7x 1.3 cm) Shipping Weight: 1.2oz (37 g) ENVIRONMENTAL Operating Temperature: 32°F - 120 °F (0°C - 49°C) Humidity: 10 to 93% non-condensing) ELECTRICAL RATINGS Operating Voltage: 15- 32VDC SLC Standby and Alarm Current: 350jiA End-of-Line Resistance: 47KW Initiating Device Circuit Wiring Resistance: 1,500W max SLC Loop Resistance: 40W max. Wire Length: 6" min. ORDERING INFORMATION IDP-Minimon: Minature Monitoring Module For a complete listing of all compilance approvals and certifications, please visit www.farenhyt.com. Microsoft. Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell and System Sensor are registered trademark of and Farenhyt' is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All soecifications are subject to change without notice. For Technical Support, Please call 800-446-6444. For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security & Fire 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 350279 I Rev HI 08/17 2017 Honeywell Inteinational Inc Honeywell THE POWER OF CONNECTED CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, lDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, 5K-Mon-1 0, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, lDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Honeywell FarenhytTM Series THE POWER OF CONNECTED Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo, DP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP- Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with the Farenhyt Series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be setwith rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. It is UL 268A listed when used with the DNR (W) duct smoke detector. Installation The I OP-Photo and IDP-Photo-T plug into a compatible IDP- series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detector. :—,---- ___- 7/ N- IDP-PHOTO (BASE NOT INCLUDED) Compatibility The IDP-Photo, IDP-Photo-T and IDP- PhotoR are compatible with the following IDP series detector bases: B2IOLP 6" Mounting Base B501 4" Mounting Base B224B1 6" Isolator Base B224RB6" Relay Base B200SR 6" Sounder Base The lOP-Photo, IOP-Photo-Tand IDP-PhotoR are compatible with the following Farenhyt Series FACPs: IFP-2100/ IFP-2100ECS/ RFP-2100 IFP-2000 / lFP-2000ECS / RPS-2000 IFP-1000 / IFP-I000ECS lFP-300 / IFP-300ECS IFP-100 / IFP-IOOECS lFP-75 IFP-50 FEATURES & BENEF I TS Sleek, low-profile Superior EMI Detector transmits design resistance for signal to indicate Reliable analog reliability maintenance is communications for Simple field cleaning required trouble-free operation for code compliance Optional remote LED Age resistant polymer Variety of mounting annunciator (System housing options to meet any Sensor PN RA100Z) Dual electronic application Plug-in mounting thermistor design on Dual LED indicators provides ease of the IDP-Photo-T for 3601 visibility installatioii CSFM Listed MEA Listed 225-02-E Vol. V Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed FM Approved Wiring OP-Series Detector Mounting Bases DP-Photo, JDP-PhotoR and IDP-Photo-T Technical Specifications For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. SPECIFICATIONS* Physical: Height: 2.0(5.08cm) less sensor Diameter: 4.1 (10.4CM) installed in 8501 base ENVIRONMENTAL Operating Temperature: lOP-Photo: 32°F - 120°F (0°C - 49°C) IDP-Photo-T: 32°F - 100 IF (01C - 38°C) Humidity: 10 to 93% non-condensing) ELECTRICAL RATINGS Operating Voltage: 15- 32VDC SLC Standby and Alarm Current: 300 pA OTHER RATINGS IDP-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0- 4000 fpni (0- 20 m/sec) (suitable for installation in ducts) IDP-Photo Insect Screen Hole Size: 0.016" (0.41 m ni) rio in in at ORDERING INFORMATION IDP-Photo: Photoelectric Smoke Detector lOP-Photo-I: Photoelectric Smoke Detector with Thermal (135°F) lDP-PhotoR: Photoelectric Smoke Detector. remote test capable, for use with DNR (W)duct smoke detector ACCESSORIES RA100Z: Remote LED Annunciator. XR213: Detector Removal Toot. A removal and replacement toot for IDP plug-in detectors. Includes the T55-127-000. M02-04-01: Detectorlest Magnet M02-09-00: Test Magnet with Telescoping Handle XP-4: Extension Pole for XR2B. Extends from 5- 15 ft. T55-127-000: Detector Removal Head. BCK-200B: Black Detector Kit. For lOP-series detectors. * Unless otherwise noted, specifications apply to lOP-Photo and lOP-Photo Microsoft Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation Honeywell is a registered trademark of and Farenhyt is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all Specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.co In Honeywell Security & Fire 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3502801 Pen.J InS/I 7 2017 Honeywell International Inc. Honeywell THE POWER OF CONNECTED CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1JJ77 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models IDP-PHOTO, IDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model lDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 04000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division