Loading...
HomeMy WebLinkAbout3753 YVETTE WAY; ; FPR2023-0077; Permit111 (ity of Carlsbad Print Date: 04/24/2025 Job Address: 3753 YVETTE WAY, CARLSBAD, CA 92008-2559 Permit Type: FIRE-Construction Residential Work Class Parcel #: 2052806000 Track #: Valuation: $114,000.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPR2023-0077 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 11/22/2023 Issued: 01/05/2024 DEV2022-0138 Finaled Close Out: 05/20/2024 Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Robinson, Jarrod Plan Check #: Cheung, Nathaniel Project Title: KELLEY ADU Description: KELLEY ADU -NEW 13D SPRINKLER SYSTEM FOR NEW ADU (13 HEADS) Applicant: FPContractor: JOSE BARAJAS FIRE PROTECTION JOSE BARAJAS FIRE PROTECTION JOSE BARAJAS JOSE BARAJAS 2159 GREEN BRIAR DR 2159 GREEN BRIAR DR FALLBROOK, CA 92028-4387 FALLBROOK, CA 92028-4387 (760) 419-1269 (760) 419-1269 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $157.00 FIRE NFPA 13D Single Family System (Plan Review) $310.00 Total Fees: $467.00 Total Payments To Date: $467.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: KELLEY ADU Contract No. : 0042 City: CARLSBAD, CA 92008 Project Location: 3751 YVETTE WAY Date: 11/21/2023 Contractor Information Name of Contractor: JB FIRE PROTECTION Address: P0 BOX 1711 City: FALLBROOK, CA 92028 Phone Number: (760) 419-1269 E-mail: JBFIREPROTECTION@GMAIL.COM Name of Designer: JB FP Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name Remote Area Location BEDROOM Occupancy Classification NFPA 13D Density (gpm/ft2) 0.056 Area of Application (ft2) 288 Coverage per Sprinkler (ft2) 144 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 21 Required Pressure at Source (psi) 49.1 Type of System Wet Volume - Entire System (gal) 25.5 gal Water Supply Information Date 11/20/2023 Location 3751 YVETTE WAY Source Notes File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 TYCO Fire Protection Products Page 1 Job KELLEY ADU Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lbs/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 72 500 67 Node at Source Static Pressure Residual I Pressure I I Flow I Available Pressure I I Total Demand I Required Pressure I (psi) (psi) (gpm) I (psi) I (gpm) I (psi) I 1 72 67 500 72 21 49.1 Hoses Inside Hose Flow/ Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 16 lnRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 16 Other Required Margin of Safety (psi) 0 BOR - Pressure (psi) 16 BOR -Flow (gpm) 16 Demand w/o System Pump(s) N/A File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: KELLEY ADLJ Hydraulic Analysis for: I File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright© 2002-2012 Tyco Fire Protection Products Page 3 Job: KELLEY ADU Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 -Static 0 72 S2 Supply point #2 - Residual 500 67 Dl Elevation Pressure 0 4.8 D2 System Demand 21 49.1 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin Pressure (psi) I Flow (gpm) I Pressure (psi) I © Flow (gpm) Supply 72 26.3 22.8 21 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft 2) (gpm/psi½) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead Sprinkler 144 3 0.05 7.2 7.1 0.056 8 7.1 102 Overhead Sprinkler 144 3 0.05 7.2 7.1 0.056 8 7.2 File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 4 Job KELLEY ADU Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psil/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 101 10 3 8 1 2x(BM.Tee-8r)=10 7.39 150 7.1 29 10.5 8 1.101 10 0.0124 -0.2 17.39 0.2 29 10.5 -0.8 1 4x(BM.Tee-Run)=4 34.67 150 7.1 19 10.5 7.2 1.101 2x(BM.Tee-Br)=10 19 0.0101 0 ______ ______ ________ ____________ lx(BM.90)=5 53.671 0.5 19 10.5 8.9 1 3x(BM.90)=15 14.2 150 7.6 R-O 4.5 16 1.101 lx(BM.Tee-Run)=1 16 0.045 2.6 30.2 1.4 R-O 4.5 0 1 0.5 11.6 RESI-RISER R-I 4 16 0 0 6.4099 0.7- 0.5 3.2 R-I 4 0 1 2 150 15 BOR 2 16 1.101 0 0.045 0.9 2 0.1 BOR 2 0 1 lx(us.Tee-Br)=6.75 1 150 16 3B 1 16 1.025 6.75 0.0637 0.4 7.75 0.5 3B 1 5 1 2x(us.90)=5.4 4 150 16.9 3A -1 21 1.025 5.4 0.1053 0.9 9.4 1 3A -1 0 1.5 3x(BM.45)=6 170.33 150 18.8 2A -1 21 1.598 2x(BM.90)=16 30 0.0121 0 lx(BM.Tee-Br)=8 200.33 2.4 2A -1 0 1 2x(us.90)=5.4 4.5 150 21.2 BF-0 2 21 1.025 5.4 0.1053 -1.3 9.9 1 BF-0 2 0 1 0.5 20.9 950XL BF-1 2 21 0 0 11.0183 0 *** 0.5 5.5 BF-I 2 0 1 2x(us.90)=5.4 4.5 150 26.4 2-0 -1 21 1.025 5.4 0.1053 1.3 9.9 1 2-0 -1 0 .5 0.5 28.8 WATER METER 2-I -1 21 0 0 28 0 0.5 14 2-I -1 0 .75 lx(us.Tee-Br)=2.77 10 150 42.8 1A -1 21 0.745 2.77 0.4981 0 12.77 6.4 1A -1 0 8 1 150 49.1 1 -1 21 7.98 0 0 0 1 0 1 49.1 File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 Job: KELLEY ADU Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/p5i1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 102 10 3 8 1 lx(BM.Tee-Br)=5 2.11 150 7.2 27 10.5 8 1.101 lx(BM.90)=5 10 0.0125 -0.2 12.11 0.2 27 10.5 0.8 1 4x(BM.Tee-Run)=4 22.25 150 7.1 19 10.5 8.9 1.101 2x(BM.Tee-Br)=10 14 0.015 0 _______ 36.25 0.5 19 7.6 Path No: 3 G5 1 5 1 0.5 150 16.9 3B 1 5 1.025 0 0.0074 0 0.5 0 3B 16.9 Path No: 4 29 10.5 0 1 1x(BM.Tee-Run)=1 4.84 150 7.1 27 10.5 0.8 1.101 lx(BM.90)=5 6 0.0002 0 10.84 0 27 7.1 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 15.47 ft/s occurs in the following pipe(s): (1A-2-I) '"" Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 6 Job: KELLEY ADU Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 75- 70- 65- 60 55. 50- 45- 40- 35- 30- 25 20- 15 tO- 5- 0- r 0 0 0 0 0 0 0 0 0 N N N Flow, gpm Pressure Loss Function Design Area: 1; BFP Ref.: 70 (950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 5. 5 p s i @ ~21 g~p ~m 0 Flow, gpm File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 2 10 .1 9.! 8.1 Job: KELLEY ADU Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 71 (WATER METER, Size = .5); Inlet Node: 24; Outlet Node: 2-0 Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 72 (RESt-RISER,, Size = 1); Inlet Node: R-l; Outlet Node: R-O 0 Il 0 0 0 Cl en '0 Flow, gpm File: E:\jobs\jobs\42_KELLEY ADU\42_KELLEY ADU.dwg Date 11/21/2023 Copyright 2002-2012 Tyco Fire Protection Products Page 8 Weight Unit 0.0 0.00 0.0C 2.0 12.00 192.00 0.1 4.50 4.5C 0.1 6.70 6.7C 1.4 13.75 178.7 2.8 14.75 221.2E 6.4 603.2C 0.3 2.20 256.4 0.3 256.4 0.0 0.00 0.0 0.0 0.00 0.0 0.0 0.0c $ 859.69 11/21/23 22:32 Material Summary (FIRST PAGE) Qty Description Part # Vendor # CPVC Fittings 1 1" CPVC V-CHECK #002 002 002 16 1" CPVC 90 Eli CPVC 80026 1 1" CPVC Cap CPVC 80101 1 1" CPVC Coupling CPVC 80076 13 1" x 1/2" CPVC-Thrd Adapter CPVC 80176W (West) 15 1" CPVC Tee CPVC 80001 CPVC Fittings Pipe 117' Pipe 1" PVx15 BiazeMa Plastic 0.5 80301 Bundles Pipe Sprinkler Heads 11 Pend BRA Tyc LFII NPT 3.00 155 51-010-1-155 2 Pend WHI Tyc LFII " NPT 3.00 155 51-010-4-155 Sprinkler Heads GRAND TOTAL 6.7 Material Summary - LAST PAGE PAGE 1 Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 ( vertical 3/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/2", 2") CSA® Listed (vertical 3/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") * City of Los Angeles Approved (vertical 1 1/2", 2") NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM Springs Stainless steel, 300 series Features Sizes: 3/4", 1", 1 1/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Dimensions & Weights (do not include pkg.) Options (Suffixes can be combined) - with full port QT ball valves (standard) Accessories Repair kit (rubber only) Thermal expansion tank (Model XT) 0 QT-SET Quick Test Fitting Set MODEL SIZE in. mm DIMENSIONS (approximate) A in. mm B LESS VALVES in. BALL mm C in. mm D in. mm E in. mm F in. mm NTH BALL VALVES lbs. kg 3/4 20 111/4 286, 7 178 11/2 38 3 76 31/2 89 3 76 7 3.2 1 25 12 1/4 311 7 178 11/2 38 3 76 31/2 89 3 76 12 5.4 11/2 40 171/8 435 109/16 268 2 51 31/2 89 41/2 114 41/2 114 22 10 2 50 181/4 460 109/16 268 2 51 31/2 89 41/2 114 41/2 114 28 12.7 *Size 1-1/4" Discontinued Zurn Industries, LLC I Wilkins Rev. G 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 4/20 In Canada urn Industries Limited Document No. BF-950XL 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 Product No. Model 950XL www.zurn.com Page 1 of 2 DIRECTION OF FLOW Flow Characteristics 0 Rated Flosv, (established by approval agencies) MODEL 950XL 3/4", 1", 1 1121t & 2" (STANDARD & METRIC) FLOW RATES (Its) 15 1.26 2.52 3.8 5.0 15 3.2 6.3 9.5 12.6 15.8 . __ I I ___ U) ,, ___ CL 1 1/2" (40mm) __________ 103 3/4 (20mm) ___________ Cl) 10 _______ ______ ______________ _____ _____ ______ ____ ________ ____ 10 ______ ___________ _________ ________ __________________ ______ ______ ________ _____ 50mm) 69 " ________ ________ 0 ______ ______ _____ —J ________ _____________ ______ _____ w cc 5 ________ _________________ ______ ______ ______________ ______ a: 35 (I) U) ________ ________ _________________ ______ ________ ________ ______ w WO cc °- 0 20 40 60 80 0 50 100 150 200 250 0- FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 1/8'.1 1 2 3 1/4" 2 2 3 5 3/8' 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4' 23 35 47 70 1 1/2' 32 48 63 95 1 52 1 78 1 105 1 167 PROTECTIVE OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the device from the line. The Double Check Valve Backf low Preventer shall be a ZURN WILKINS Model 950XL. Zurn Industries, LLC j Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 Al COMPONENTS DESCRIPTION 1 Manifold body, male thread x male thread 2 Inline check valve, spring-loaded 3 Flow switch with retard q Drain valve, with optional pressure relief valve 5 Pressure gauge, 0-300 psi RESI-RISERTM i iNATIONAL FIRE PRODUCTS Pre-assembled, compact fire sprinkler riser unit for residential sprinkler systems FEATURES S BENEFITS Manifold is manufactured as a one- piece casting that is air-tested for leaks Raised lettering on both sides allows installation to the right or left and easily identifies the flow direction and test and drain outlet Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring Flow switch has dual SPDT switches and a retard of 0-90 seconds Optional "all-in-one" cost-saving combination pressure relief valve/test and drain valve is available Unique, compact design allows installation within standard frame construction and in tighter spaces TECHNICAL DATA Sizes: 1", 1-1/4", 1-1/2", 2" Style: Thread x thread Riser Body Finish: Cast brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi pressure relief valve/test and drain In accordance with NFPA 13,13R and 13D Flow switch and pressure gauge are UL Listed DIMENSIONS DESCRIPTION 1" i-ii'r 1-1121, 20 A Height* 13" 13" 13" 13" B Width" 11" 12" 12-1/4' 12-3/4' C Depth 3-1/2" 3-1/2" 3-1/2' 3-1/2" - Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover Without check valve With or without pressure relief valve ©2019 National Fire Products 0819 1342881 RESI-RISERTM i iNATIONAL II FIRE PRODUCTS MODEL NUMBERS WITH INLINE WITH SWING WITH PRESSURE WITH CPVC PART # CHECK VALVE CHECK VALVE RELIEF VALVE ADAPTERS F77 I SR100-IR4 SRIOO-R4 SR100-SR4 1 SR100-IRR4 I I SR100-SRR4 I I SR100-IR4-TD 1 1 SR100-SR4-TD I I SR100-IRR4-TD I I I SR100-RR4-TD I I SR100-SRR4-TD I I I SR125-IR4 I SR12S-R4 SR125-SR4 I SR125-IRR4 I I SR125-SRR4 I I SR125-1R4-TD I SR125-SR4-TD I I SR125-IRR4-TD I I SR125-RR4-TD I I SR125-SRR4-TD I I I SR150-IR4 I SR15O-R4 SR150-SR4 I SR1BO-iRR4 I I SRI50-SRR4 I I SRi 5O-R4-TD I I SRi 50-SR4-TD I I SR150-RR4-TD I I I SR150-RR4-TD I I SRi 50-SRR4-TD I I I laD SR200-1R4 I SR200-R4 SR200-SR4 I SR200-IRR4 I I SR200-SRR4 I I SR200-1R4-TD I I SR200-SR4-TD .1 I SR200-IRR4-TD I I I SR200-RR4-TD I I SR200-SRR4-TD I I I 02019 National Fire Products 0819 1342881 RESI-RISER"' NATIONAL FIRE PRODUCTS HOW IT WORKS: PRESSURE RELIEF/TEST S DRAIN Normal Position: Relieving pressure Manual Open: Locked closed for Static pressure exceeding 175 psi Drain or flow switch test hydrostatic test PRESSURE LOSS 12 10 8 Oil 0 10 20 30 40 50 60 70 80 90 100 Flow (gpm) 1' 1-1/4' 1-1/2" 2" ©209 National Fire Products 0819 1342881 -n B A C 5 RESI-RISERTM i I NATIONAL FIRE PROOUCTS INLINE SPRING CHECK VALVE COMPONENTS DESCRIPTION MATERIAL 1 Nut Stainless Steel 2 Spring Cap Stainless Steel 3 Spring Stainless Steel q 0-Ring Seat Rubber 5 Clapper, Spring-Loaded Brass 6 Body Brass 7 Washer Teflon" DIMENSIONS 1" i-i/'r 1-1/2" 2' A 1-9/16" 2" 2-1/8" 2-3/4' B 3-1/4' 3-5/8' 4" 5" C 1-3/16" 1-9/16" 1-3/4" 2-3/16" 02019 National Fire Products 0819 1342881 tqC00 Worldwide I Contacts www.tyco-fire.com BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook lH-1900. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page lot 2 AUGUST 2018 TFPI9I5 TFPI9I5 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision dote and are subject to change without notice. NAI1ONAL FIRE PROTECTION ASSOCIATION and NFPA are rogsrored cadnmorlra of NotionS Fire P,ot0000n acsuc,oticni BLAZEM.ASTER Iso I,odetnorkol The Lub,iaol Corporotlon Johnson //J Controls Important Information with Regards to Your Tyco® BlazeMaster® CPVC Fire Sprinkler System CONGRATULATIONS, your building structure contains a state of the art life safety system. Your CPVC fire sprinkler system will enhance the safety and security of your building when properly cared for. CPVC Fire Sprinkler Products resist attack from a wide range of chemicals that are corrosive to metallic piping. As with any piping material, there are however, certain chemicals that can be detrimental to CPVC. Occasionally some of these chemicals may be found in some construction products, site preparations and building maintenance. There are certain things that you need to be mindful of in caring for or working around your CPVC fire sprinkler system. Keep your system clear from contact with the following products and chemicals unless product labels state materials are compatible with CPVC: Ordinary considerations Property maintenance services Cleaning Products Fungicides Mold Detergents Remediation Oils/Lubricants/Greases Chemicals Termiticides / Rubbery Materials Insecticides For hired contractors & do-it-yourselfers Corrosion Inhibitors Glycol-based antifreezes Solder Flux Thread Sealants Flexible Cable /Wiring (especially communications cabling) Caulks/Mastics Adhesive Vinyl / Electrical Tape Non-Water Based Paint Paint Thinners Wood Finishes/Varnishes Consult www.Lubrizol.com before installing spray foam insulation You should also avoid the following: Sitting, standing, hanging, leaning, or resting anything on the pipe, fittings, and sprinkler heads Grounding electrical wiring to the pipe or fittings Ambient temperatures below 40°F140C where your fire sprinkler system is located (Unless an approved compatible antifreeze or insulation method is installed) Hot work around the pipe, i.e. blow torches, soldering, etc. FBA'29-, Visit www.BlazeMaster.com and review the FBCTM System Compatible Program section for more information. SYSTEM COMPATIBLE Be certain that this document is reviewed and understood by anyone working on or around your CPVC sprinkler system. Proper care will help your CPVC fire sprinkler system provide protection for years to come. FOR ADDITIONAL INFORMATION CONTACT OUR TECHNICAL & ENGINEERING SERVICES TEAM AT 1-800-381- 9312 Johnson '1 Controls . This building contains a Tyco® BlazeMastei® CPVC fire sprinkler system. This CPVC fire sprinkler system is a Life Safety Assembly and must be treated carefully. Please read the following before any activity which could contact this system: CPVC piping components may be damaged by certain substances and construction practices. - DO NOTstack, support, hangequipment,orhangflexiblewire/cable, especially communications cable, orother material on the fire sprinkler system. - ONLY system compatible materials including, but not limited to solvent cements, caulks, sealants, cutting oils and thread pastes as noted bythe CPVC fire sprinkler piping system manufacturer's installation instructions should be used in contact with thissystem. - DO NOTexpose CPVC products to incompatible substances, such ascuttingoils, packing oils, traditional pipethread pastes anddope,fungicides, termiticides, insecticides, detergents, buildingcaulks, adhesive vinyl, electrical tape, solder flux, flexible wire/cable (with special consideration forcommunications cabling), and non-approved spray foam insulation materials. - DO NOT expose CPVC products to edible oils, solvents, or glycol-based anti-freeze fluids. - DO NOT expose CPVC products to open flame, solder, and soldering flux. - DO NOT drop, distort, or impact CPVC products or allow objects to be dropped on them. - DO NOT use two-part epoxy paint. There is no known issue with other types of paints being applied in normal 1 coats to CPVC, including water-based latex paints, alkyd paints, enamels, spray paints, or paints with added mold inhibiting ingredients. Visit www.BlazeMaster.com and review the FBCTM System Compatible Program SYSTEM COMPATIBLE section for more information. Failure to follow this notice may cause cracks or fractures to develop in CPVC products resulting in property damage due to leaks or flooding. The presence of any visible cracks may require partial or full system replacement. For additional information contact the general contractor or the fire sprinkler system installer. FOR ADDITIONAL INFORMATION CONTACT OUR TECHNICAL & ENGINEERING SERVICE TEAM AT 1-800-381-9312 Johnson 410 Controls Bulletin 135 April 2021 Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutcheons and conical concealed cover pates Product Description Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The Fl Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model Fl Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, Residential Sprinkler Summary Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non- recessed) and Model W4 (recessed, concealed) are required. wr L the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. I Table Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/ps1112 (lpm/bar112) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1Res30 R3511 Pendent 3.0 (43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) E1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) Fl Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) El Res30 CCP R3511 Pendent 3.0(43) 1/2 conical concealed 14 x 14 (4.3 x 4.3) Fl Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) El Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res76CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20x20(6.1 x6.1) F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) Note: Please note SIN difference between Fl Res58 HSW (R3533) and Fl Res58 HSWX (RA3533). www.reliablesprinkler.com Threads Wrench Flat Sealing Assembly 2-1/4 i'll Lfl..SJ') Glass Bulb (57) Load Screw Deflector Components (32mm) Dimensions 1-3/4° (44mm) +/- 1/4(6mm) F2 & P/ Recessed Escutcheon Installation 2-1/4 (57mm DIA. 1-15/16" (49mm) DIA. Face of fitting to finished ceiling 1/2 (13mm) +1- 1/4°(6mm) Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPTorlSO7-1R1/2 Sensitivity Nominal KFactor: 3.0 (43 metric) Fast-response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings .. - 155°F(68°C) Material Specifications Thermal Sensor: 3 mm glass bulb 175°F (79°C) Recessed Escutcheons i , Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Model Fl Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems111 Maximum Coverage Area(') ft. x ft.(m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 7 12 x 12 (3.7 x 3.7) 8(30) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 X 14(4.3 X 4.3) 10(38) 11.0(0.76) 15 x 15(4.6 x 4.6) 12(45) 16.0(1.1) 16x16 (4.9x4.9) 13(49) 18.8(1.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2of15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1R1/2 Sensitivity Nominal K-Factor: 4.9 (71 metric) Fast-response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) I Thermal Sensor: 3 mm glass-bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Button: Copper Alloy Fl Recessed F2 Recessed \ Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-114 (57mm)____ 2-1/4° (57mm) *(4g)1DlA* finished ce of fitting (4 mm)ceiling 115/1 1 to finished 5/8' (16mm( 2°(l3mm) 3/8' (9mm) 1/4' (6mm) Fill 039VU 2-1/4" 1-5/8"(4lmm) +1- (44mm1 DIA I Faceoffithng DI Aceilin g/4"(6mm) 9mm1 L 3181 2-718172mm1 DlA.- _____________ (32mml 2- 7/8°(72mm) DIA Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems0t Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 7 12 x 12 (3.7 x 3.7) 13(49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13(49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17(64) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15(57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16(61) 10.7(0.74) 16 x 16 (4.9 x 4.9) 17 (64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0 (1.03) 20 x 20 (6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 April 2021 www.reliablesprinkler.com to finished ceiling 5/8"(l6mm) +1- 3/8"(9mm) Fl Recessed Escutcheon Installation Dimensions Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1R1/2 Sensitivity Nominal K-Factor: 5.8 (84 metric) Fast-response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155-F (68-C) Material Specifications 175-F (79°C) Thermal Sensor: 3 mm glass bulb Recessed Escutcheons IT Sprinkler Frame: Brass Alloy Button: Copper Alloy Fl Recessed F2 Recessed Sealing Assembly: Nickel Alloy with PTFE FV Recessed' Load Screw: Bronze Alloy Sprinkler Wrenches r Deflector: Bronze Alloy Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4 (57mm) 2-1/4 (57mm) h-r DIA. T1 Face of tittirlo hr DIA. -T1 Face of tlttlni 1-15/16' to finished (49mm) DIA. ceiling 1/2(13mm) I +1- 1/4"(6mm) Iii J ) 1-3/4 (44mm) +/- 1/4 (6mm) 2-7/8 (72mm) DIA. F2 & Pd Recessed Escutcheon Installation Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst" Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16x 16(4.9x4.9) 16(61) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(l.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 iiIi1 Page 4 of 15 www.reliablesprinkler.com 2021 prinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Sensitivity Threads: 3/4" NPT or lS07-1R3/4 Nominal K-Factor: 7.6 (109 metric) Fast-response ('•\ Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Material Specifications 175°F (79°C) Thermal Sensor: 3 m glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W2 Deflector: Bronze Alloy Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4° (57mm) _ l/J +/- 3/8" (9mm) ceiling ceiling 5/8(16mm) 7 ;(49) DIA. 1-15/16 to finished 16° to finished 1/2(13mm) +1- 1/4"(6mm) ro3s DIA. Face of fitting ' Face of fitting 1 5/8° (41 mm) +1- (6mm) 3/8(9mm) 1-3/4° (44mm) +/- (44mm) L2718 (72mm) DIA. - 2-7/8° (72mm) DIA. 1/4 Dimensions Fl Recessed Escutcheon Installation F2 & P1 Recessed Escutcheon Installation Model F1Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemsttt Maximum Coverage Area() Flow Pressure Deflector to ft. x ft. (m x m) gpm (li'min) psi (bar) Ceiling Distance 18 x 18(5.5 x 5.5) 21 (80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20(6.1 x 6.1) 23(87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page of 15 April 2021 www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPTorlSO7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model Fl Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions - 2-5/8° (67mm) 2-5/8" (67mm) I DIA. 1 1 DIA. 7-1 2-5/16° (59mm)DlA. ace of fitting to finished ceiling I I _________________________ _________________________ Face of fitting to finished ceiling I 1/4°(32mm) I 1-1/4° (32mm) 1/4° (6mm) 7777= ________ 1/4° (6mm) (24mm) -.. 1/4" (6mm) L3-3/1\6(78mvm)- DIA. FPRecessedEscutcheonInstallation Model Fl Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria iiiiiiiiiiingram Minimum Flow and Residual Pressure in Wet Pipe Systems0i Maximum Coverage Area (2) ft.xft.(mxm) Flow gpm(I/mm) Pressure psi (bar) I Deflector to Ceiling Distance I 12 X 12(3.7 x 3.7) 8(30) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 14x14(4.3 x 4.3) 11(38) 13.4 (0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ell Page 6 of 15 April 2021 www.reliablesprinkler.com ace of fitting to finished ceiling -1/4 (32mm) I- 1/4° (6mm) 1° (25mm) I- 1/4° (6mm) ace of fitting to finished ceiling -1/4° (32mm) I- 1/4° (6mm) 15/16 (24mm) O..IQ" 17-,-.,1 FP Recessed Escutcheon Installation 9iP." (A7-m\ CCP Recessed Escutcheon Installation Technical Specifications Finishes Style: Conical Concealed Pendent and (See Table N) Recessed Pendent Sensitivity Threads: 1/2" NPT or 1507-1R1/2 Fast-response Nominal K-Factor: 4.9 (71 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F (570C)* Thermal Sensor: 3 mm glass bulb FP Recessed* Sprinkler Frame: Brass Alloy Sprinkler Wrenches Button: Copper Alloy Model W4 Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy *Note: Model PP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions Model Fl Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(" Maximum Coverage Area2 ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14(4.3 x4.3) 13(49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16.7(l.15) 16x 16 (4.9x4.9) 14(53) 8.2 (0.57) 18 x 18 (5.5 x 5.5) 18 (68) 13.5(0.93) 20x20(6.1 x6.1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 7 of 15 April 2021 ellaNd www.reliablesprinkler.com ace of fitting to finished ceiling 1/4(32mm) - 1/4" (6mm) 1° (25mm) - 1/4" (6mm) ace of fitting to finished ceiling -1/4' (32mm) /- 1/4" (6mm) 15/16' (24mm) FP Recessed Escutcheon Installation CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPTorlSO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems1 Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18 (5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20 (6.1 x 6. 1) 22(83) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 illii Page 8 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4" NPT or 1S07-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model W4 *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions ,) CZ10-1 107-1 2-5/8 (67mm) DIA. 2-5/16 (59mm)D1A ace of fitting to finished ceiling 1/4" (32mm) /- 1/4(6mm) 15/16 (24mm) L3-3/18" (78mm) 0 Face of fitting to finished ceiling 1-1/4° (32mm) +1- 1/4(6mm) - 1(25mm) +1- 1/4° (6mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Table Minimum Flow and Residual Pressure in Wet Pipe Systems11) Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x4.9) 21 (80) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 22(83) 8.4 (0.58) 20 x 20(6.1 x 6.1) 25(95) 10.8 (0.75) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 9 of 15 April 2021 Hellabil www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPT or 1S07-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8" (41 mm) 3/8(10mm) +/ 1/4(6mm) +1- 1/4" (6mm) 7 2-7/16(62mm) 5/16' J (8mm) 2-1/4" 1-15/16" (57mm) (49mm) - - - DIA. DIA. Top of Deflector Down from Ceiling lobe Either 4' to 6' (100 to 150 mm) or 610 12' (15010300mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model Fl Res44 Horizontal Sidewall Sprinkler Hydraulic Desian Criteria Table Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area (2) ft. x ft. (m x m) Flow gpm (1/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 12(45) 7.5 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.70) 15x 15(4.6 x4.6) 15(57) 11.6 (0.80) 16 x 16(4.9 x 4.9) 16(61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23(87) 27.4(1.89) 18x 18(5.5 x 5.5) 19(72) 18.7(l.29) 12 x 12(3.7 x 3.7) 14 (53) 10.2 (0.7) 61012 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15(4.6 X 4.6) 16(61) 13.2 (0.91) 16 x 16(4.9 x 4.9) 17 (64) 15.0(1.03) 16 x 18(4.9 x 5.5) 20(76) 20.7(l.43) 16 x 20(4.9 x 6.1) 23(87) 27.4(l.89) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0,1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 10 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Finishes Style: Conical Concealed Sidewall (See Table N) Threads: 1/2' NPT or ISO 7-1 R1/2 Sensitivity Nominal K-Factor: 4.4 (63 metric) Fast-response Max. Working Pressure: 175 psi (12 bar) Temperature Ratings 155°F (68°C) Material Specifications 175°F (79°C) SWC Thermal Sensor: 3 mm glass-bulb Cover Plates Sprinkler Frame: Brass Alloy SWC Conical Concealed Plate(2) Button: Copper Alloy SWC-2 (Slotted) Conical Concealed Plate (3) ____ 5' Sealing Assembly: Nickel Alloy with PTFE Sprinkler Wrenches Load Screw: Bronze Alloy Model W4 Deflector: Bronze Alloy SWC-2 Note: 1"Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2)135'F SWC Conical Concealed Plate for 155°F (68°C) sprinklers ° 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions 1" (25mm) 1" (25mm) '1- 1/4' (6mm) - +1- 1/4' (6mm) Face of fitting to finished wall 2-7/16" (62mm)-- 5/16 j (8mm) Dimensions (67mm) (58mm) -- DIA mml SWC & SWC-2 Concealed Cover Plate Installation Top of Deflector Down I from Ceiling to be Either 3 5/16 4" to 6" (100mm to (84mm) 150mm) or 6' to 12" DIA. (150mm to 300mm) Based on Hydraulic I Calculations Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F(68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (11mm) Pressure psi (bar) Flow gpm (I/mm) Pressure 12 x 12(3.7 x 3.7) 13(49) 8.7 (0.60) 14 (53) 10.2 (0.7) 4 to 6 inches 14 x 14 (4.3 x 4.3) 14(53) 10.2 (0.7) 14 (53) 10.2 (0.7) 15 x 15(4.6 x4.6) 16(61) 13.2 (0.91) -- 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) -- - - (100 to 150 mm) 16 x 18 (5.5 x 5.5) 19(72) 18.7(1.31) --- -- 16x20 (4.9x 6.1) 23(87) 27.4(l.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) -- -- 14x 14(4.3x4.3) 15(57) 11.7 (0.81) -.- -- 6 t 12 inches (150 to 300 mm) 15 x 15 (4.6x 4.6) 17(64) 15.0 (1.03) -- 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16 x 18 (4.9x 5.5) 20(76) 20.7(l.43) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 jjji Page 11 of 15 April 2021 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPTorlSO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-5/8 (41 mm) 3/8(10mm) +/- 1/4(6mm) +1- 1/4° (6mm) 2-7/16 (62mm) 2-/4° 1-15/16° (57 DIA. mm) (49mm) DIA. - - 5/16 j (8mm) i Top of Deflector Down from Ceiling to be Either 4 to 6 (100 to 150 mm) or 6° to 12° (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model Fl Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table L Minimum Flow and Residual Pressure in Wet Pipe Systems{hi Maximum Coverage Areai2i ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 25.0(1.72) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 X 15(4.6 X 4.6) 19(72) 10.7 (0.74) 16 x 16(4.9 x 4.9) 21 (80) 13.2 (0.91) 16 x 18(5.5 x 5.5) 25(95) 18.6(l.28) 16 x 20(4.9 x6.1) 29(110) 12 x 12 (3.7 x 3.7) 22 (83) 14.4(l.0) 6 to 12 inches (150 to 300 mm) 28.6(l.97) 14 x 14 (4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15(4.6 x 4.6) 24(91) 17.1 (1.18) 16 x 16(4.9 x 4.9) 26(98) 20.1 (1.39) 16 x 18(4.9 x 5.5) 31 (117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Please note SIN difference between Fl Res58 HSW (R3533) and Fl Res58 HSWX (RA3533). Bulletin 135 !iJIiI Page 12 of 15 www.reliablesprinkler.com 2021 sprinkler.com Finishes Technical Specifications (See Table N) Style: Sidewall and Recessed Sidewall Sensitivity Threads: 1/2' NPT or 1S07-1R1/2 Fast-response Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass bulb F2 Recessed Sprinkler Frame: Brass Alloy FV Recessed Button: Copper Alloy Sprinkler Wrenches Sealing Assembly: Nickel Alloy with PTFE Model W2 Load Screw: Bronze Alloy Model W4 (Recessed) Deflector: Bronze Alloy Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8(48mm) 3/8°(lOmm) +1- 1/4(6mm) +1- 1/4(6mm) F2-7/8" (73mm) (8mm) 2-1/4" 1-15/16' (57mm) (49mm) Dr. DIA. Top of Deflector Down From Ceiling to be Either 4° to 6" (100 to 150 mm) or 6" to 12° (1 5b to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems'" Maximum Coverage Area(') ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18x20(5.5x6.1) 30(114) 26.8(1.85) 4 to 6 inches (100 to 150 mm) 52.4 (3.63) 20x 20(6.1 x6.1) 30(114) 26.8(l.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 18x 20 (5.5x6.1) 35(133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 62.9 (4.34) 16 x 22 (4.9 x 6.7) 38 (144) 1 42.9 (2.96) 16 x 24 (4.9 x 7.3) 42 (160) 52.4 (3.61) 14 x 26 (4.3 x 7.9) 46(174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Please note SIN difference between F1Res58 HSW(R3533) and F1Res58 HSWX(RA3533). Bulletin 135 Page 13 of 15 April 2021 • www.reliablesprinkler.com Model W2 Model W4 Model W4 Wrench Installation Finishes Standard Finishes Special Application Finishes Sprinkler') Fl, F2. FV, FPM, CCP, SWC (Conical) Sprinkler " Fl, F2. FV, FP(3), CCP, SWC (Conical) Escutcheons Cover Plates (1) Escutcheons Cover Plates (I) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Satin Chrome Satin Chrome Satin Chrome White Polyester (2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester -- -- Electroless Nickel -- PTFE (2) -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (COP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8' (67 mm) for FP recessed escutcheons, CCP SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and 'Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and IS07-1R1/2: 8-18ft-lbs (11 —24N-m) 3/4" NPT and ISO7-1 R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Bulletin 135 April 2021 TI" The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model Wi wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5(125mm) long extension (not provided) as shown in Figure 13. Page 14 of 15 www.reliablesprinkler.com Maintenance Reliable Model Fl Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or IS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) W4 (Recessed and Concealed) Note: Please note SIN difference between Fl Res58 HSW (R3533) and F1Res58 HSWX (RA3533). It) c) 0 N-0) 0) 0) 0) 0) 0 Bulletin 135 jjjbI Page 15 of 15 April 2021 www.reliablesprinkIer.com