HomeMy WebLinkAbout7020 MANZANITA ST; ; FA080053; Permit4/24/25, 3:18 PM FA080053 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 7020 MANZANITA ST Permit Type: FALARM Parcel No: 2155041100 Lot #: 0 Permit No: FA080053 Status: ISSUED Applied 8/22/2008 Approved: 8/25/2008 Reference No.: Issued: 8/25/2008 PC #: Inspector: Project Title: SUNRISE ASSISTED LIVING MONITORING SYSTEM PLAN CHECK & INSPECTION Applicant: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Owner: AL I/LA COSTA SENIOR HOUSING L L C C/O GLASER FINANCIAL GROUP INC 2177 YOUNGMAN AVE ST PAUL MN Fees ($) Add'I Fees ($) Total ($) L Balance ($) 125 I 0 125 0 about:blank 1/1 tuca / Fire & / Si,nplexGrinnell I Security August 21, 2008 SimplexGrinnell 3568 Ruffin Road Fire Marshal - Plan Review San Diego, CA 92123 City of Carlsbad Fire Department Phone (858) 633-9100 Gregory Ryan Fax (858) 633-9101 1635 Faraday Avenue Carlsbad, CA 92008 RE: Sunrise Assisted Living Hood Monitoring Relocation Greg, Attached to this letter is the Existing Fire Alarm system at the Sunrise Assisted Living of La Costa. On FA-03 you will find the 3 Hood System monitors we intend to move to a new location in the within the Kitchen. Our intent is to re-use the existing monitors in place currently. However, in the case of demolition, these may be lost. Attached as well is a cutsheet and listing for the direct replacement monitor module and an installation detail has been added to FA-06 as well as the symbol list on FA-01. Also attached is previous email conversation regarding this project. Thank you in advance for your review. Sincerely, Douglas Daniels Design Engineer SimplexGrinnell San Diego - - Mplex SI9L[l llE REC0l[R CO 4090 -90 SOPEVIS[I l O ISl. 911R 511-131 SATE coo- h DNErrN4 iDifi11 FI*1 Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® and IDNetTM Communicating Devices, and MEA (NYC) Approved* Individual Addressable Module (lAM) 4090-9001 MAPNET II or IDNet addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from TAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor or electrically noisy applications Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Provides current limited monitoring (for use with IDNet communications): To monitor tamper switch (trouble) and waterfiow switch (alarm) on same circuit using one point Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be latched, such as from rate-of-rise heat detectors UL listed to Standard 864 * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code, See CSFM Listing 1300-0026:223 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796025. 4090-9001 Supervised IAM (shown approximately full size) 'ri'ti The 4090-9001 is an individual addressable module (JAM) with both power and communications supplied by a two-wire MAPNET II or IDNet circuit. It provides location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Closure of the monitored contacts initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not applicable with 2120 CDT). For use with IDNet communications only, the 4090-9001 can sense normal, open circuit, short circuit, and current limited conditions. With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. © 2000 Simplex Time Recorder Co. All rights reserved. S4090-0001-4 8/00 lAM Module Model Number I Description 4090-9001 j Supervised lAM module Optional Trim Plates and Mounting Bracket Model Number Description 4090-9806 Trim plate with LED viewing window, requires 4090-9810 For semi-flush mounted box 4090-9807 mounting bracket, includes mounting screws For surface mounted box 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates ILS ifti3ii1 Electrical Power and Communications - MAPNET II or IDNet, auto selected, I address per lAM Input Requirements Normally open, dry contacts Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire Supervision Resistor Resistors for Current Limited Operation (for use with IDNet communications only Wiring Distances Distance from lAM to Contacts 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance, MAPNET II or IDNet, 2500 ft (762 m) maximum from fire alarm control panel per Channel 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 1 9/16W x 1 3/4" H x 1 1/4" D (40 mm x 44 mm x 32 mm) Housing Material Black thermoplastic Temperature Range 320 to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) - 6.8 kQ, 1/2 W NOTE: Refer to installation instructions 574-331 and field wiring diagrams 1.8 kQ and 4.7 kn, 1/2W 841-804 and 842-073 for additional information. 500 ft (152 m) maximum without protectors Simplex Time Recorder Co. 2 S4090-0001-4 8/00 1H SIni Sl?1 fI[ 409090010 U4[ coos. LED viewing port itLiIfiatI3iT 4090-9001 IDNet Field wiring shown supervised lAM for reference Single gang electrical box 2 1/2 (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 41/4" (108 mm) Light pipe for I LED viewing 41 /2" (114 mm) 0 k 2 1/2" (64 mm) 4090-9806, Trim plate for semi-flush mounted box 213/16" (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED Simplex Time Recorder Co. 3 S4090-0001-4 8/00 Simplex, the Simplex logo, 1t4APNETII, and IDNet ale either trademarks or registered trademarks oJSimplex Tune Recorder Co in the U.S. and/or oilier countries. S4090-0001-4 8/00 SIJrr1Iex Westminster, Massachusetts 01441-0001 USA ir' visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are Subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:223 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models* 4090-9001, -9001TSP, -900ITTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and -9106TTP Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rec 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division