Loading...
HomeMy WebLinkAbout3207 GREY HAWK CT; ; FPC2023-0056; Permitcity of Carlsbad 0 FireT1Ier1 mix i1t - Print Date: 05/01/2025 Permit No: FPC2023-0056 Job Address: 3207 GREY HAWK CT, CARLSBAD, CA 92010-6663 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2210150100 Track #: Applied: 03/23/2023 Valuation: $0.00 Lot #: Issued: 04/04/2023 Occupancy Group: Project t: Finaled Close Out: 11/01/2023 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Cheung, Nathaniel Plan Check #: Salcedo, Felix Project Title: Description: THE FORUM AT CARLSBAD -REPLACE FIRE ALARM CONTROL PANEL & ANNUNCIATOR (ADDRESSABLE) Applicant: FPContractor: STANDARD ELECTRONICS ACCENT ELECTRONICS JESUS LEDEZMA 613 W MAIN ST 9340 STEVENS RD EL CAJON, CA 92020-3323 SANTEE, CA 92071-2810 (619) 596-9950 (619) 596-9950 FEE AMOUNT FIRE TI Fire Alarm System $735.00 Total Fees: $735.00 Total Payments To Date: $735.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Ph: (619) 596-9950 March 1, 2023 Standard Fax (619) 596-8850 613W. Main St. I 92020 C7. c" LIC. #590876 Electronics JJ BSISACO #AC01903 IA Installer #S3570-1 StandardElectronics.us SUBMITTAL SHEET PROJECT: 3207 Grey Hawk Ct. FA Panel Repl. - 3091 ELEC.CONTR: EQUIPMENT Fire Alarm System ITEM QTY DESCRIPTION MODEL NO. DATA SHEET S3 Addressable Fire Control Panel 1 1 SFM#:7 165-1703:0176 SLP-BLK FCI System Sensor Loop Card 2 1 SFM#:7165-1703:0176 SLC-PM FCI LCD Color Touchscreen Display 3 1 SFM#7165-1703:0176 LCD-SLP FCI Remote Enclosure, A2 Size, Black, For LCD Annunciator 4 1 SFM#7165-1703:0125 E3BB-BA2 FCI CLSS Gateway, IP & Cellular Communicator HON-CGW- 5 1 SFM#7300-1637:0504 MBB FCI 6 1 LTE Cellular Communication Module, Verizon CCM-VZ-HON FCI 7 1 Battery Enclosure for ES 17-12 Batteries SSU00505 Space Age 8 2 12 VOLT 18 AH Sealed Lead Acid Battery ES17-12 MK Battery 9 1 Fire Alarm Document Storage Box SSU00690 Space Age DflOB'SR,et1D Analog and Networking Systems *Ganal S3 Series Control Pa nel Sma[[Add ressable Fire Alarm Control Panel General The Gamewell-FCI®, S3 Series Intelligent Fire Alarm Control Panel provides the latest, innovative high-end processing power. The S3 Series panel is a digital, microprocessor-based system that offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports the following types of networks. Up to 64 nodes using the 7100 Series panel. Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ethernet connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series configuration consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and as seven amp power supply. The SLID main board provides either one ortwo SLC loops in the Class A or B configuration that supports either of the following protocols: Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maximum device count to 252 devices. LikPLJ S3 Series FEATURES & BENEFITS Listed per ANSI/UL® Standard 864 9th Edition IBC Seismic Certified Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7) Supports a network system of up to 122 nodes (includes E3 Series® panels) or up to 64 nodes (includes 7100 Series) System Sensor supports up to 318 intelligent devices and each SLC loop supports the following - up to 159 detectors - up to 159 modules (expandable to 636 maximum per panel) Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel) Includes a high resolution (4.3") (10.92 cm) color touchscreen display Provides 7.0 amp power supply (120VAC or 24OVAC) Includes four Class Bor two Class A built-in Notification Appliance Circuits (NAM Provides selectable System Sensor, Cooper-Wheelock, or Gentex' strobe synchronization Supports up to 32 serial annunciators (LCD, LED-only, LED Switch) Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint® Graphic Workstation connectivity Provides two fully- programmable Form-C contacts for Fire, Trouble, and Supervisory TimeCap - Saves time and dateupto48 hours without any power or battery Automatically adjusts to any NAC End-of- Line Resistor (EOL) value (lk-55k ohm) for legacy audible/visual appliances Removable display can be used as a remote annunciator Suitable for pre-action deluge applications General Four Class B or two Class A NACs can be wired and synchronized using the System Sensor, Cooper- Wheelock®, or Gentee strobes. To retrofit the SLID on the existing audible/visual appliances, the on-board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3'(10.92 cm) color touchscreen display screen shows the following: Events on the system Status of analog addressable devices Complete diagnostic fault codes/messages Five programmable function buttons with LED status for accessibility to the following functions: - Disable/Enable - Trouble Acknowledge - Bypass Output - Alarm Acknowledge - Lamp Test - Custom-defined Application The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a user-friendly interface makes panel operation and system maintenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may customize the system to precisely suit the needs of the building owner. Auto-programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3' (10.922 cm) color touchscreen displays system status, event details and service modes. On the front of the panel, six LEDs show the following conditions. Fire • Silenced Hazard (Gas or CO) • AC Power Supervisory • Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well-suited for retrofit applications. The SLID provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the legacy FCI, 7100 and Gamewell, 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3-UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell- FCl's FocalPoint Graphical Workstation. Figure .1 LCD-SLP Display Optional Accessories DACT-E3 - DiaLer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It connects to the SLID through an RS-485 bus. Using the Contact ID format, the DACT-E3 provides a four-digit account code followed by the code/numbers listed below: Three-digit Event Code Two-digit Group Number Three-digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: Contact ID • SIA 3+1 .4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLID fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted-pair wiring. The RPT-E3- UTP is available with two add-on fiber modules: FML-E3 connects to the network using either 62.5/125 micron multi-mode fiber. FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the following data sheets: RPT-E3-UTP Data Sheet, P/N: 9020-0609. FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 ICA LCD-7100 - Remote Annunciator The Remote serial display features an 80-character display. The LCD-7100 can be surface or flush- mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 -48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located ULO Listed annunciator enclosure. Up to 16 ANU-48 modules can be connected to the SLP panel. For more information, refer to the ANU-48 Data Sheet, P/N: 9020-0596. Figure 2 illustrates the S3, SLP-BB Cabinet Enclosure. S3, SLP-BB CABINET S3, SLP-BB CABINET OUTER 000R 20 118H 41120 Figure 2 S3, SLP Enclosure Ordering Information SLP-BLK: SLP addressable FACP in black S3, SLP-BB enclosure. Requires either an SLC-PM or an SLC95- PM for SLC loops. SLP-RED: SLP addressable FACP with red door and black S3, SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED-G: SLP addressable FACP 240VAC power supply with red door and black S3, SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLC-PM: System Sensor Loop Card - 1 loop used for 159 sensors and 159 modules. For use with the S3 panels only. SLC95-PM: Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the S3 panels only. Accessories DACT-E3: Digital Dialer CommunicatorTransmitter for the S3 or E3 Series. LCD-SLP: LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E3BB-B42, E3BB-RA2) RPT-E3-UTP: Network repeater card with twisted-pair, fiber connections. Requires either an FML-E3 or an FSL-E3 card. FML-E3: Multi-mode fiber-optic card for one channel on the RPT-E3-UTP. FSL-E3: Single-mode fiber-optic card for one channel on the RPT-E3-UTP. SLP-RB: SLP motherboard For use with the replacement or the retrofit solutions. FLPS-7-RB: SLP 120V4C 74 power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT: SLP Retrofit Kit for the 7100 B-Slim and 1F602 panels. Includes the new door and the mounting plate. Requires the following: SLP-RB • FLPS-7-RB SLC95-PM • LCD-SLP SLC-PM S3BB-RB: SLP red cabinet with an inner door for the mounting display behind the locked, plexi-glass door. Requires the following: SLP-RB • FLPS-7-RB SLC95-PM • LCD-SLP SLC-PM LCD-7100: Remote Serial LCD Annunciator ASM-16: Remote Programmable Addressable Switch! LED Module ANU-48: Remote LED Driver Module Figure 3 illustrates the various S3 Series configuration options that are available. Supports up to 636 Velociti devices or 252 XP95 devices S3 Series C:= Panel Fire Alarm Control DNR Intelligent Duct MCS-COF Networked uD~7C '. Detector 6FIrCarrn MonoxIde panels using twisted- D ect0T pair wire or fiber optics. ASD.PL2F ASD-LS Photo Detector Laser Detector AMM-21F AMM-211IF Mint Monitor Module Dual Input/Output Module Local E3 Series Energy Trip tJ Panel AOM-2RF MS-7AF I I Ethernet Relay Module Pull Station LCD-7100 LCD-SLP LCD-E3 -ii I Remote Annunicator CnlorTnuCtcnOO Remote Annuolcator g : 3 13 FocalPoint Workstation IW ASM-16 ANU-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 S3 Series Panel Configuration Options 4 S3 Series Control Panel Technical. Specifications SYSTEM Device Loops: Up to two Class A or B, System Sensor units, each loop supports up to 318 device addresses. OR- Apollo units, each loop supports up to 126 device addresses per loop. NAC Circuits: Four Class B or 2 Class A (2.0 A each circuit), 6.0 A total NAC Operating Voltage: 24 VDC NAC Minimum Voltage: 19.5 VDC ® 20.4 V battery voltage SLC Loop Circuit Operating Voltage: 24 V peak-to-peak Input Voltage: 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current: 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power (Resettable): Two Auxiliary circuits, 24 VDC, 1.75 A Aux Power Supervised Class 2 Power-Limited (Non-Resettable): (maximum current of 1.75 is shared between two circuits). Base Panel Current Draw: Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature: 32°-1201 F (01-491 C) Relative Humidity: 93% (non-condensing) Battery Charger Voltage: +24 VDC Battery Charger Capacity: 55 A/H batteries (cabinet accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts: Form-C, 2 amps ® 24VDC (resistive) Cabinet Dimensions: S3, SLP-BB Dimensions: 14 1/2"Wx20 1/8"Hx4 1/2" D (36.83W x 51.18 H x 11.43 D cm) S3BB-RB Dimensions: 19 3/8"Wx19 3/8"Hx4.5" D (49.22 W 49.22 H x 11.430) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0— 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F. STANDARDS The S3 Series Control Panel is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEAFDNY: C0A6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewelt- fci.com/en-uS/ documentation/Pages/ Listings.aspx E3 Series®, FocalPoint®, Gamewelt-FCI®, and System Sensor® are registered trademarks of Honeywell International Inc. Cooper-Wheelock® is a registered trademark of Cooper-Wheelock Corporation. Gentex' is a trademark of Gentex Corporation. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's S3 Series Control Panel and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9021-60730 I H 109/17 92017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0176 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACTE3; Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS7RB; Power Supply *RPT..E3.UPT. Network Repeater *ASM16 P/N i 100-0455; Annunciator Switch *ANU_48; P/N 1100-0503; Annunciator *LCD7100; Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. Rev 08-30-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division IbiNL III I IW'Ek.i.iii.I Networking Systems SLC Personality Loop Modules General The Gamewell-FCI®, S3 Series (Small Addressable Fire Alarm Control Panel) signaling line circuits (SLCs) provide the communication between the S3 Series fire alarm control panel and the SLC devices. Each SLP-E3 (Smart Loop Panel) main board supports either one or two of the following plug-in SLC-Personality Modules. SLC-PM (Signaling Line Circuit Personality Module) SLC95-PM (Signaling Line Circuit-95-Personality Module) The SLC-PM/SLC95-PM modules provide one SLC loop in Class B or Class A wiring. The SLC-PM supports the following devices: Up to 318 System Sensor Velociti® devices. - 159 sensors and 159 modules Up to 198 System Sensor CLIP devices. - 99 sensors and 99 modules The SLC95-PM supports the following devices: Up to 126 Apollo XP95 devices. - 126 sensors and modules Installation The SLC-PM/SLC95-PM modules are designed to be plugged into the Smart Loop Panel-Main Board (SLP-E3). This feature allows you to expand the S3 Series (Small Addressable Fire Alarm Control System without the need to remove or replace hardware. Ordering Information SLC-PM: System Sensor, Signaling Line Circuit-Personality Module with up to 318 devices SLC95-PM: Apollo SLC Personality Module with up to 126 devices o 8 :J ? 00 H e98Ø I? SLC-PM (System Sensor) 0 1c SLC95-PM (Apollo) FEATURES & BENEFITS Listed per ANSI/UL Standard 864 9th Edition SLC-PM supports the System Sensor Velociti protocol using up to 318 devices - Uses up to 159 sensors and 159 modules SLC95-PM supports the Apollo XP95 protocol using up to 126 devices - Uses up to 126 sensors and modules Supports Class A or Class B Wiring Offers a simple, plug-in installation feature SLC-PM/SLC95-PM Technical Specifications SYSTEM STANDARDS For a complete listing of all SLC-PM SLC95-PM The SLC-PM/SLC95-PM are designed to comply compliance approvals and certifications, please visit: Operating Current: 0.014 amp 0.016 amp with the following standard: http://www.gamewell- Alarm Current: 0.014 amp 0.016 amp UL Standard: UL 864 9th Edition fci.com/en-US/ Line Impedance: 40 Ohms documentation/Pages! Line Capacitance: 0.5 uf max. AGENCY LISTINGS AND APPROVALS Listings.aspx Operating Voltage: 24 VDC FWR Operating Temperature: 321 to 120° F (01 to 49° C) These listings and approvals apply to the modules Velociti® and Gamewell-FCI® Relative Humidity: 0 to 93°/o,non-condensing at specified in this document In some cases, certain are registered trademarks of modules or applications may not be listed by certain Honeywell International Inc. 90° F (32° C) approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL is registered trademark TEMPERATURE AND HUMIDITY RANGES of Underwriters Laboratories UL Listed: S1869 Inc. This system meets NFPA requirements for operation at 0 FM Approved - 490C/32 - 120°F and at a relative humidity 93% ± 2°/s MEA FDNY: COA #6162 This document is not intended RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). to be used for installation However, the useful life of the system's standby batteries CSFM: 7165-1703:0176 purposes. We try to keep our and the electronic components may be adversely affected City of Chicago Approved: Class 1 product information up-to- by extreme temperature ranges and humidity. Therefore, it Reference Certificate of Compliance: VMA 45894-02C date and accurate. We cannot cover is recommended that this system and its peripherals be iso 9001 Certification all specific applications or anticipate all requirements. installed in an environment with a normal room All specifications are subjectto temperature of 15— 271C/60 - 80°F change without notice For more information Learn more about Gamewell-FCl's SLC-PM!SLC95-PM and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9021-60781 I E 109/17 EHJotmeyiieDll www.honeywell.com ©2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:0176 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterfiow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACTE3; Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS7RB; Power Supply *RPTE3UPT. Network Repeater *A5M16 P/Ni 100-0455; Annunciator Switch *ANU48; P/N 1100-0503; Annunciator *LCDjiOO; Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 08-30-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ks*v operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division 'raialamsmi rcii1 ARE CONTROL Lrt±IJI INSTRUMENTS by Honeywell Description The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annnciator display used with the S3 Series and E3 Series Systems. The LCD-SLP provides an easy-to-use, intuitive interface for the operator's control. The 4.3" (10.92 cm) color touchscreen display shows the following: System Status • Service modes Event details The following identify the LED Indicators that display on the panel. AC (green) • Supervisory (yellow) Fire Alarm (red) • Trouble (yellow) Hazard (blue) • Silenced (yellow) The five fully-programmable front panel switch/LED combi- nations provide a direct access to perform the following tasks: Device Bypass • Lamp Test Enable/Disable Groups or Devices The display features the following physical switches. Menu • System Reset Five Programmable • Drift Walk Test Switches Installation The LCD-SLP is adaptable for installation in the S3, E30 Series or Retrofit cabinets. For additional information, refer to the E3 Series Cabinets Data Sheet, P/N:9020-0649 S3 Series Cabinets - SLP-BB basic system enclosure - S3BB-BB/S3BB-RB system enclosure E3 Series® Cabinets - AA size cabinet (E3BB-BAA, E3BB-RAA) - A2 size cabinet (E3BB-BA2, E3BB-RA2) - A size flush cabinet (E3BB-FLUSH-LCD) - B-Slim cabinet (E3BB-RBSLIM) - B size cabinet (E3BB-BB, E3BB-RB) - C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) - D size cabinet (E3BB-BD/lNCC, E3BB-RD/INCC) Retrofit Cabinets - IF600-RETROFIT - 7200-B-RETROFIT - 7200-C-RETROFIT Specifications Operating Voltage: 24 VDC FWR Operating Current: 0.030 amp Alarm Current: 0.065 amp Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93%,non-condensing at 90° F (32° C) E3 Sedes®is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwrtter's Laboratories Inc. -—Th ftrJrftrp LCD Touchscreen Annunciator Display i t 0 LCD-SLP Features Listed per ANSI/UL® Standard 864 9th Edition UL Listed and FM approved for Pre-Action/Deluge and Agent Releasing. Provides 4.3(10.92cm) color touchscreen display of System Events. Includes five custom function buttons with LEDs for direct access to system controls. Offers the following installation options: - Locally mounted in the S3 Series panels. - Remotely mounted in the E3 Series, A2 cabinet or LCD Flush enclosure. Displays the following six LED indicators: -Alarm -Hazard - Trouble - NAC Silence - Supervisory - AC Power Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases. Both the E3 Series (ILl-MB-E3/1L195-MB-E3) and the S3 Series (SLP) support up to 15 LCD-SLP displays via the RS-485 serial interface. Ordering Information Part Number Description LCD-SLP LCD Touchscreen display unit E3BB-BA2 Remote enclosure with inner door, black, one LCD slot E313B-RA2 Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD Remote flush mounting enclosure, black, LCD slot SIGNALING City of MEA N MpROVED FDNY: Approved R1 $1869 COA-06162 7165.17e3:e176 Class I RofronroC.,Uosat of Compllno VMA.45894.02C 11 IS09001 GAMEWELL-FCI . IS lilY IfITINI 12 Clintonville Road, Northford, CT 06472-1610 USA Tel. (203) 484-7161 Fax. (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell.FCI for their use. 2016 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60782 Rev. F page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 10 LISTING No. 7165-1703:0176 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model S3 fire alarm control unit. Automatic, manual, waterflow, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. System components: SLP-E3; Smart Loop Panel Main Board Subassembly LCD-SLP; Liquid Crystal Display- Smart Loop Panel Subassembly FML-E3; Fiber Optic Multi Mode Board FSL-E3; Fiber Optic Single Model Board SLC-PM; Signaling Line Circuit for System Sensor Devices SLC95-PM; Signaling Line Circuit for Apollo Devices SLP-BB; Basic System Enclosure - Backbox, Door, Mounting Plate *DACT..E3; Digital Alarm Communication Transmitter *LCDE3; LCD Display *FLPS7RB; Power Supply *RPTE3UPT; Network Repeater *ASMI6 P/N i 100-0455; Annunciator Switch *ANU_48; P/N 1100-0503; Annunciator *LCD7100; Remote LCD Display. Refer to the listee's data sheet for additional detailed product description and operational considerations RATING: 120 V, 60 Hz, 2.75 A 240 V, 50/60 Hz, 1.4 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 08-30-17 gt ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division E3 Series® Cabinets E3 SEMEV UBOME7S Cabinets used for the E3 Series System I The E3 Series® Cabinets offer a variety of I cabinet options to house either the E3 Series or S3 Series fire alarm control panel systems. GENERAL Cabinet 44 offers 2 slot or 3 slot options to The E3 Series® Expandable Emergency accommodate any of the followi ng configurations: Evacuation System by Gamewell-FCI offers - Inner door, 2 slots allows space for one several cabinet size options. The E3 Series LCD-E3 or LCD-SLP and one ASM-16 System is a modular design that allows a wide - Inner door, 3 slots allows space for any range of configurations to form an integrated, combination of three modules: ASM- distributed fire alarm system. These cabinet 16, NGA or an ANU-48 options allow for sturdy and modern Cabinet Al houses one NGA orone installations. The E3 Series cabinet assembly 45M-16/ANu-48. is a compact, wall-mounted enclosure. A Cabinet 42 accommodates a single typical cabinet includes a backbox and an LCD-E3. outer locking door. In addition, there are E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. several inner door options and mounting The E3BB-R-B-Slim or B-Slim contains the plates to accommodate a variety of E3 Series 600 Series cabinet. Cabinet B includes a sub-assemblies, mounting plate that contains a space for the Each cabinet backbox includes mounting following modules: patterns for plates to allow the installer to ILI-MB-E3/lLI95-MB-E3 arrange and secure the sub-assemblies to the PM-9/PM-9G sub-assemblies backbox. The backbox knockouts are also positioned at numerous points to allow a Batteries set inside the backbox conduit access into the enclosure. Additional sub-assembly options mounted on There are four Annunciator cabinet sizes the backbox include the DACT-E3 and RPT- which providethe maximum flexibility thatcan E3. The 2 slot inner door houses the following meet any application: options: one LCD-E3 module and either one ASM-16/ANU-48 or one NGA module FEATURES AND BENEFITS IBC Seismic Certified • Designed with Lexan® windows that 16-gauge steel backbox appear on the outer doors of most Offers cabinets available in either black cabinets, except the following cabinets or red that contain louvered doors: Designed with a 900 opening door with zero clearance Contains a keylock with a quarter turn Latch Provides removable cabinet outer and - Cabinet "C" INX • Optional Trim Ring accessories - Cabinet"D" INX available inner doors - Cabinet INX CAB-B Includes an inner door bonding strap • Furnished backbox and door ground used to provide electrical continuity for studs provide positive grounding. 1800 grounding opening door with full clearance ltc.i i'j licti GENERAL Both the C and 0 size Command Center cabinets house a variety of E3 Series Broadband sub-assemblies that can be used in multiple configurations that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and 0 size Command Center cabinets that may contain any of the following: fire fighter's phone handset microphone optional modules to meet the facility operation requirements. Refer to the Inner Door and Backbox Mounting Capacities in the Ordering Information Section. ORDERING INFORMATION Inner Door Mounting Capacity: Cabinet "AA" Size: Dimensions: 19W10"H x 4 1/2"D, (49W x 25H x 11.40 cm) E3BB-BAA: tosure, Black, "AA" (LOC) Size E3BB-RAA: Enclosure, Red, "AA" (LOC) Size E302-TA: Inner Door, 2 Slots, (INCC-TEL & ASM-16) E31D2-A: Inner Door, 2 Slots, (LCD-E3 or LCD-SLP & ASM-16) E31D3-A: Inner Door, 3 Stots,(NGA, ASM-16 and MIC) Cabinet "AA1" Size: Dimensions: 8 3/4"W x 10"H x 4 1/2"D, (22W x 25H x 11.4D cm) E3BB-BAA1: Remote Enclosure, Black, w/Inner Door, 1 slot, (NGA) E3BB-RAA1: Remote Enclosure, Red, w/Inner Door, 1 Slot, (NGA) Cabinet "A2" Size: Dimensions: 13 1/4"W x 10"H x 4 1/2"D, NOW x 25H x 11.4D cm) E3BB-BA2: Remote Enclosure, Black, w/Inner Door, 1 Slot, (LCD-E3 or LCD-SLP) E31313-RA2: Remote Enclosure, Red, w/Inner Door, 1 Slot, (LCD-E3 or LCD-SLP) Flush Cabinet A2 Annunciators: Dimensions: 13 1/4W x 10"H x 4 1/2"D, NOW x 25H x 11.4D cm) E3BB-FLUSH-LCD: CAB A2 Remote Flush LCD ANN with Key switch operation E31313-NGA-FLUSH: CAB A2 Remote Flush NGA ANN with Password protected Cabinet "13-Slim" Size: (Retrofit Kits): Dimensions: 14"W x 20"H x 4 1/2"D, (35.5W x 50.81-1 x liD cm) E31313-RBSLIM: Assembly, Enclosure, B-SLIM, Red with Backplate and LCD-E3 Keyswitch plate. IF600-RETROFIT: Door and Cab mounting plates, disable key switch and door lock (PK-625) for E3 Series upgrade. ORDERING INFORMATION (CONTINUED) Cabinet "B" Size: Dimensions: 19 3/8"W x 19 3/8"1-1 x 4 1/2"D, (49W x 49H x liD cm) E31313-1313: Assembly, Backbox Enclosure, Black,"B" Size E31313-RB: Assembly, Backbox Enclosure, Red, "B" Size E302-13: Inner Door, 2 Slots, "B" Size 1100-0460: INX-Transponder 19" (cm) Backbox with Door, Black Dimensions: 19 3/8"Wx19 3/8"Hx4 1/2"D, (49Wx49Hx11.43 D cm) Cabinet "C" Size: Dimensions: 19 3/8"W x 30"H x 4 1/2"D, (49W x 76H x liD cm) E3138-13C/INCC: Enclosure, Command Ctr, Black, "C" Size E3BB-RC/INCC: Enclosure, Command Ctr, Red, "C" Size E31D2-C: Assembly, Inner Door, Command Center, 2- Bay "C' Size E31D3-C: Assembly, Inner Door, Command Center, 3-Bay "C" Size E31313-13C/INX: Assembly, Transponder, Black, "C" Size E3BB-RC/INX: Assembly, Transponder, Red, "C" Size E3-INCC-CPLATE: Command Center module mounting plate, "C" Size E3-INX-CPLATE: Transponder mounting plate, "C" Size Inner Door Mounting Capacity: E3-ILI-CPLATE: Intelligent loop module mounting plate "C" Size Cabinet "0" Size: Dimensions: 19 3/8"W x 41"H x 4 1/2"D, (49W x 104H x liD cm) E3BB-BD/INCC: Enclosure, Command Center, Black, "D" Size E3BB-RD/INCC: Enclosure, Command Center, Red, "D" Size E3102-D: Assembly, Inner Door, 2-Bay, "0" Size E31D3-D: Assembly, Inner Door, 3-Bay, "D" Size E31313-13D/INX: Enclosure, Transponder, Black "D" Size E31313-RD/INX: Enclosure, Transponder, Red, "0" Size E3-INCC-D-PLATE: CommandCentermodu[emountingplateD-Size E3-INX-D-PLATE: Transponder module mounting plate, "D" Size Optional Extender Plates: AM-50 Plate: AM-50 Extender Plate FPT-GATE-3-EXT: FPT-GATE-3 Extender Plate Optional Accessories: 1100-0450: Command Center, blank plate, single size E3-BP: Inner door panel, blank, double size 90375: PM-9/PM-9G Adapter Plate Kit, Hardware E3-TRI MKIT-A: Trim kit for "A"/"AA" size enclosure, black E3-TRIMKIT-A1: Trim kit for "AAi" size enclosure, black E3-TRIMKIT-A2: Trim kit for "A2" size enclosure, black E3-TRIMKIT-B: Trim kit for "B" size enclosure, black E3-TRIMKIT-C: Trim kit for "C" size enclosure, black E3-TRIMKIT-D: Trim kit for "D" size enclosure, black Page 2 of 5— 9020-0649:X ORDERING INFORMATION (CONTINUED) Inner Door Mounting Capacity Bulk Amplification: Part Number Number AA-100: 100W Audio Amplifier, @70.7 VRMS with 120 vc ofComponents Cabinet AA AA-120:120 W Audio Amplifier, @25 VRMS with 120 VAC E31D2-A - (Cabinet AA, Inner Door, 2 Slots) ACT-1: Audio coupling transformer, for audio systems LCD-E3 Display and ONE w/multiple supplies. ASM-16/ANU-48 ONE FCI-CHG-120: Battery Charger, 25-120 A/H Gel cell E31D2-TA - (Assembly, Door, Inner, TEL-E3) FCI-LBB: Battery box, accommodates batteries up to 55 A/H, E31D3-A -(Cabinet A, Inner Door, 3 Slots) (Black). NGAorASM-16 ONE ASM-16s/ANU-48 TWO Cabinet C: Cabinet AA1 FCI-DR-C4B: Large Battery Backbox, Blank door, lock & keys, E3ID-AI - (Cabinet AA1, Inner Door (includes Box) for backbox accepting 3 chassis, (Black). NGAorASM-16 ONE FCI-DR-C4BR: Blank door, lock & keys, for backbox Cabinet A2 accepting 3 chassis, (Red). E3ID-A2 - (Cabinet A2, Inner Door, (includes Box) SBB-C4: Backbox, 3 chassis, (Black) LCD-E3 B ONE Cabinet Cabinet D: E3ID2-B - (Cabinet B, Inner Door, (includes Box) FCI-DR-D48: Blank door, lock & keys, for backbox accepting LCD-E3 Display and one ASM-16/ANU48 ONE 4 chassis, (Black) NGA and one ASM-16/ANU-48 ONE FCI-DR-D4BR: Blank door, lock & keys, for backbox accepting B-Slim Cabinet 4 chassis, (Red) LCD-E3 Display & one RPT-E3 or one DACT-E3 ONE SBB-DA: Backbox, 4 chassis, (Black) ILl-MB-E3 or one lL195-MB-E3 ONE 90516: 7100-Slim 7 A/H Seismic Battery Bracket Kit PM-9 or one PM-9G Cabinet C ONE Seismic Battery Bracket Kits: E31D2-C - (Cabinet C, Inner Door, 2 Slots) E3 B-Slim 7 A/H Seismic Battery Bracket Kit LCD-E3 Display and ONE 90517:7100-Slim 12 A/H Seismic Battery Bracket Kit Any combination of ASM-16/ANU-48, NGA or FIVE E3 B-Slim 12 A/H Seismic Battery Bracket Kit Microphone Assemblies 90518: E3 CAB-B 7 A/H Seismic Battery Bracket Kit Telephone Assembly E31D3-C - (Cabinet C, Inner Door, 3 Slots) ONE E3 CAB-C 7 A/H Seismic Battery Bracket Kit Any Combination of ASM-16/ANU-48, NGA, or SEVEN E3 CAB-D 7 A/H Seismic Battery Bracket Kit Microphone Assemblies NetSOLO NS-INX 7 A/H Seismic Battery Bracket Kit Telephone Assembly ONE NetSOLO 7100 7 A/H Seismic Battery Bracket Kit Cabinet D 90519: E3 CAB-C (lNX only) 12 A/H Seismic Battery Bracket Kit E31D2-D - (Cabinet D, Inner Door, 2 Slots) LCD-E3 Display E3 CAB-D (INX only) 12 A/H Seismic Battery Bracket Kit ONE AnyCombination ofASM-16/ANU-48, or NGAor ELEVEN NetSOLO NS-1 NX 12 A/H Seismic Battery Bracket Kit Microphone and 90520: E3 CAB-B 18 A/H Seismic Battery Bracket Kit Telephone Assembly ONE E3 CAB-C 18 A/H Seismic Battery Bracket Kit E31D3-D - (Cabinet D, Inner Door, 3 Slots) E3 CAB-D 18 A/H Seismic Battery Bracket Kit Any Combination of ASM-16/ANU-48, NGA or THIRTEEN Retrofit Kits: Microphone Assemblies Telephone Assembly ONE For information on the Gamewell and 7200 Retrofit Kits, refer to the Backbox Mounting Capacity following Data Sheets. E3BB-BAA -(Enclosure, "AA' (LOC) Size, Black) 9021-60678: Gamewell Retrofit Kits Data Sheet lNl-VG Series Voice Gateway ONE 9021-60733: 7200 Retrofit Kits Data Sheet E3BB-BAAI - (AA1 Size Box/Door, Black) RPT-E3 Network Repeater ONE E3BB-BB B-Size Box/Door, Black PM-9/PM-9G Power Supply ONE lLl-MB-E3/lL195-MB-E3 and ONE Additional ILI-MB-E3/lL195-MB-E3 ONE Loop Interface or ANX or ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE INX CAB-B Mounting Plate PM-9orPM-9G ONE lNl-VGX ONE AM-50 Series amplifiers FOUR 9020-0649:X • 05/01/2020 Page 3 of 5 Backbox Mounting Capacity (Continued) Backbox Mounting Capacity (Continued) Part Number Number Part Number Number of Components of Components E3-INCC-C Plate E3-INCC-D Plate PM-9/PM-9G Power Supply ONE PM-9/PM-9G Power Supply ONE INI-VG Series Voice Gateway ONE lLl-MB-E3 or lL195-MB-E3 ONE ILI-MB-E3/11-195413-E3 Loop Interface and ONE Additional ILI-E3 or 1L195-E3 Series orANX FOUR Additional lLl-MB-E3/1L195-MB-E3/ANX Loop Interface or DACT-E3 Digital Communicator ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE RPT-E3 Network Repeater ONE lNl-VG Series ONE Optional AM-50 or FPT-GATE-3 Extender Plate ONE Optional AM-50 or FPT-GATE-3 Extender Plate ONE E34I-C Plate E3-INX-D Plate PM-9/PM-9G Power Supply ONE PM-9/PM-9G Power Supply ONE ILI-MB-E3 or 11-195-MB-E3 ONE lLl-MB-E3 or lL195-MB-E3 ONE Additional lLl-MB-E3/11-195413-E3 or ILI-S-E3/1L195-S-E3 or TWO DACT-E3 Digital Communicator ONE ANX RPT-E3 Network Repeater ONE DACT-E3 ONE lNl-VG Series ONE RPLE3 ONE AM-5O Series Amplifier FOUR Optional FPT-GATE-3 Extender Plate ONE Optional FPT-GATE-3 Plate ONE E3-INX-C Plate E3BB-BD - CD Size Box/Command Center (Voice), Black) PM-9/PM-9G Power Supply with one PM-9/PM-9G Adapter ONE PM-9/PM-9G Power Supply ONE Plate lNI-VG Series Voice Gateway ONE NI-VGX Voice Gateway ONE lLl-MB-E3/lL195-MB-E3/ANX Loop Interface FOUR lLl-MB-E3 Loop Interface and ONE Additional ILI-MB-E3/IL195-MB-E3/ANX Loop Interface or ONE Additional ILIMBE3/L195MBE3/ANX ONE DACT-E3 Digital Communicator and ONE DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE RPT-E3 Network Repeater ONE Optional FPT-GATE-3 Plate ONE AM-50 Series Amplifier FOUR E3BB-BD - CD Size Box/Command Center, Black) Optional FPT-GATE-3 Extender Plate ONE PM-9/PM-9G Power Supply ONE lLI-MB-E3/lL195-MB-E3/ANX Loop Interface & Additional SEVEN ILI-MB-E3/IL195-MB-E3/ANX Loop Interface or DACT-E3 Digital Communicator and ONE RPT-E3 Network Repeater ONE Optional Extender Plates AM-50 Extender Plate AM-50-25 or AM-50-70 ONE FPT-GATE-3 Extender Plate FocalPoint Gateway ONE PNET-1 ONE Optional FPT-GATE-3 Extender Plate ONE Page 4 of 5 - 9020-0649:X E3 SERIES® CABINETS TECHNICAL SPECIFICATIONS STANDARDS The E3 Series fire alarm control panel cabinets are designed to comply with the following standards: UL Standards: UL 864, 10th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterf low Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non-coded and Master Coded Operation Underwriters Laboratories Standard UL 2572, 2nd Edition (for Mass Notification Systems) UUKL for Smoke Control NFPA Standards NFPA 13- Standard for Installation of Sprinkler Systems NFPA 16- Standard for Foam-Water Sprinkler and Foam Water Spray Systems NFPA 72- National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry Chemical/17A Wet Chemical Seismic Codes International Building Codes: BC 2013 IBC 2009 lBC 2006 1 B 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) STANDARDS (CONTINUED) The E3 Series Cabinets are designed to comply with the following standard: UL Standard: UL 864, 10th Edition UL 2572, 2nd Edition for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1869 ULS 864, 10th Edition UL2572, 2nd Edition MEA Approved: 6177 MEA FDNY: COA# 6077 CSFM: 7165-1703-0125 FM Approved: 3025415 City of Chicago City of Denver VMA Seismic Certified ISO 9001 Certification E•3IS [Fit Gamewell-F@I ajegisterer1 tkademaf .ogeWetth Int'7'i9iona [III nc. LELectioy._ 't!JL is a regifë7d tradYk of p - LUadei.wrjtets Lies This doctFment is not iddf ised for iflation purpss. We tTy"to keep otFr pjoduct information to-dte and e-c7nnot, cover alt specific applications or anticipate all renuirements. All -. . LILIL specifications are subjectto chaige I,....aL.4 1_______ Lwithpo • Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203484.7161 www.gamewell-fci.com 9020-0649 I X 106/20 @2020 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 10 LISTING No. 7165-1703:0125 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: GAMEWELL-FC112 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model E3 Series® BROADBAND and E3 Series® CLASSIC Voice Evacuation System. The E3 Systems may also work in conjunction with all the sub-assemblies of listee's 7100 Series Control Panel and NetSOLO systems (CSFM Listing No. 7165-1703:0105 and 6911-1703:0116, and 6911-1703:0118). Unit conveys all fire alarm, audio evacuation, voice paging, and fire fighter communications. Power-limited; non-coded, automatic, manual, smoke control, water flow, sprinkler supervisory, local auxiliary, central station, remote station, and proprietary service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ILI-MB-E3; Intelligent Loop Interface Master Board PM-9, PM-9G; Power Supply ILI-95-MB-E3, ILI-95-S-E3; Loop Interface Subassemblies E3BB-FLUSH-LCD; Enclosure for ICD-E3 E3BB-BA/-RA/-BAA/-RAA/-BB/-RB/-BC/-RC/-BD; Cabinet RPT-E3-FO; or Repeater Sub-assembly, Fiber Optic or RPT-E3-UTP; Repeater Sub-assembly, Unshielded twisted pair wire LCD-E3; LCD Keypad Display *LCD..SLP; LCD Touchscreen Display Screen DACT-E3 sub-assembly; Digital alarm communicator transmitter ILI-S-E3; Intelligent Loop Unit, Expansion Board ANX-SR, ANX-MR-FO, ANX-MR-UTR; Addressable Node Expanders Sub Assembly INCC-E; Intelligent Network Enclosure INCC; Intelligent Network Central Command INI-VG, INI-VGC-UTP, INI-VGC-FO, INI-VGX-UTP; Intelligent Network Interface Sub Assembly lNI-VGX-FO, INI-VGE-UTP, INl-VGE-FO; Intelligent Network Interface Sub Assembly ASM-16; Annunciator Switch Sub Assembly INX; Network Audio Transponder Enclosure ANU-48; Annunciator Sub Assembly NGA; Touch Screen LCD Display Sub Assembly LCD-7100; Remote LCD Display SBB-C4, SBB-D4; Backbox *Revision 09-18-20 V'AAN r This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-1703:0125 Page 2 of 2 FCI-VDR-D4B, FCI-DR-C4B, FCI-CR-D4B; Doors with locks AA-100, AA-120; Amplifiers AM-50-25, AM-50-70; Amplifier Sub Assembly CHGI20; Battery Charger with Cabinet BC-1/FCI-LBB; Backbox IPDACT-2; IP Digital Alarm Communicator FPJ; Firefighters's Telephone Jack Receptacle FHS; Portable Firefighters's Telephone Handset 7100 Series#; Fire Alarm Control Panel or INI-7100 UTP#; Intelligent Network Interface Sub-assembly, [Twisted, unshielded wire] or INI-7100 FO#; Intelligent Network Interface RATING: 120 V, 60 Hz, 3.5 A Primary; 24 V dc, 9A Secondary INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with the above voice evacuation systems. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NPFA 72. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of alarm signaling), the Retard/Reset/Restart period shall be 30 seconds or less. *Revision 09-18-20 W'N TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division L WmT M 17B CLSS Gateway The CLSS Gateway is Honeywell Fire's interface connecting to a Honeywell fire system panel or network, serving as a portal between the panel, the cloud, and peripheral devices. The CLSS Gateway enables reading the connected device system inventory from one panel or a network of panels and transmitting this data to the Connected Life Safety Services (CLSS) cloud. The gateway board can be connected with the CLSS cloud, a configuration computer, a panel, a mobile device, and an external power supply. The CLSS Gateway is a key component for optimizing CLSS functionality. The CLSS Gateway can be used for temporary or permanent installation STANDARDS AND CODES FCC ID: PV3CGWMBB Intertek ID: 104270338NYM-001 CE Certification meeting: - EMC Directive 2014/30/EU - Low Voltage Directive (LVD) 2014/35/ EU - Radio Equipment Directive 2014/53/EU - RoHS Directive 2011/65/EU - WEEE Directive 2012/19/EU Meets the following additional requirements: - EFSG [BRE,AFNOR/CNPP, and VdS] - Incert - SBSC - EMEA - EAC ORDERING INFORMATION HON-CGW-MBB: CLSS Gateway (includes the enclosure) Panel-specific hardware kit (sold separately): includes lock, keys, and NUP cable CUSTOMER SUPPLIED EQUIPMENT Optional Equipment (Available Soon): - CCM-ATT-HON: Cellular Communication Module for AU - CCM-VZ-HON: Cellular Communication Module for Verizon - CCM-EU: EUROPE LIE radio (Not available for North America) Add-ons Activated through CLSS Site Manager (Available Soon): - BACNET Gateway Activation - MODBUS Gateway Activation - NFN Gateway Activation - CENTRAL STATION Activation Mobile device for CLSS Gateway application (either iOS or Android) FEATURES AND BENEFITS Connects directly to Honeywell fire alarm control panels or a network of FACPs Easy connection between the gateway and CLSS Checkpoint mobile application BlueTooth® mobile pairing for gateway configuration and control capability Panel connection options include standalone panel, networked panel, and standalone with Digital Voice Command Wireless or wired connection from the gateway to the CLSS cloud Can be used for portable or permanently installed applications The panel to which the gateway connects acts as the master panel, collecting data from all its devices, and sending the collected data to the gateway which sends the data to the cloud HON-CGW-MBB TECHNICAL SPECIFICATIONS Power Nominal Voltage Range: Consumes 12V to 32V DC from the fire alarm control panel (FACP) or from an external power source Current: The power requirement varies with the number of interfaces used. Typical Current Consumption: 0.14 at 24V (with wireless connection) Peak Load: 0.254 at 24V Environment Temperature: 141F to 140°F (-10°C to 60°C) Relative Humidity: 1%- 940/0 (non- condensing) Physical Enclosure Dimensions: 10.25 Lx 8 x 3.75 (26.03cm Lx 20.32cm W x 9.53cm D) Weight: 1.6 lb (0.73 kg) Wireless Transmitter VBAT:3.6V Ambient Temperature: 77°F(25° C) Output power: @module RF antenna port Target power: Meets Spectrum Mask and EVM compliance BltUth is Qep—i~t-e—red trade ma r..k o.f Bli.STG This docUment is not ifd'fbe used for installation purposes. We t17t0 keep out product information upo-dte and accTiYte.Wtannot cover all specific appjjcations or anticipate all requireme All sner.ififinns aito rhnn "wif Radio devices operating on the frequencies listed in the table below should not be installed next to each other. Wireless Power Specifications 2.4 GHz TX Power Specifications IEEE Mod Rate BW Channel Spec Units TO 1. 802.11 (MHz) (TYP) (dB) lib CCK, 1-11 Mbps 20 1-13 17.5 dBM ±2.0 DSSS hg OFDM 6-54 Mbps 20 1-13 15 dBM ±2.0 un OFDM MCSO-7 1 20 1 1-13 1 15 dBM ±2.0 hlac OFDM MCSO-8 20 1 1-13 1 114 dBM ±2.0 5 GHz TX Power Specifications ha OFDM 6-54 Mbps 20 36-48 15 dBM ±2.0 52-64 100-144 un OFDM MCSO-7 20 36-48 15 dBM ±2.0 52-64 100-144 un OFDM MCSO-7 40 36-48 15 dBM ±2.0 52-64 100-144 llac OFDM MCSO-8 20 36-48 14 dBM ±2.0 52-64 100-144 hlac OFDM MCSO-8 40 36-48 13 dBM ±2.0 52-64 100-144 hiac OFDM MCSO-9 80 36-48 12 dBM ±2.0 52-64 100-144 Honeywell Fire systems 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.fire.honeyweli.com THE FUTURE Is WHAT WE MAKE IT HON62034 I B 105-20 ©2020 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1637:0504 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Honeywell International Incøhe 'Fire-Lite Place, Northford, CT 06472 Contact: Lisa Brant (20Y484-6 105 Fax (203) 484-7309 Email: lisa.brantr(eywell.com DESIGN: Model HON-CGW-MBB Connected Life Safety Services Gateway. The primary function of the product is to provide software services and connection for remote viewing of events. The unit utilizes sole path either Ethernet or Wi-Fi or Cellular communication pathways to connect the host FACP to Honeywell Connected Life Safety Services supplemental program for remote monitoring and data transmission services of FACP events. *The product also supports both sole and dual path communication for digital alarm transmission by connecting to the Supervising Station with selectable reporting paths via Ethernet, Wi-Fi, and Cellular interface. *The methods of communications for dual path are: Primary as Ethernet/Wi-Fi and Secondary as Cellular, or Primary as Cellular and Secondary as Ethernet/Wi-fl. Intended for indoor use and dry locations. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 18-30 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 70, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and ETL label. APPROVAL: Listed as a control unit accessory for use with listee's separately listed compatible commercial and residential fire alarm control units. For a list of compatible control panels, refer to Intertek ATM for Report No. 104270338NYM-001. *Model complies with the applicable requirements in UL 864, 10th Edition. Refer to listee's Installation Instruction Manual for details. *Revision 6-23-22 VVVW 8 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division CLSS 4G LIE Communicators The CLSS LG LTE Communicators transmit alarm, supervision, and system test messages from a protected premises to a central receiving station. The Honeywell CLSS 4G LIE cellular plug-and-play module comes with factory-mounted SI M. When mounted on the CLSS Gateway (P/N HON-CGW-M BB), it enables cellular communications to relay high-data signals from fire alarm control panels to mobile devices through the Connected Life Safety Services (CLSS) Cloud. STANDARDS AND CODES CCM-ATr-HON -FCC ID: RI7LE9IONAV2 -IC: 51314-LE91ONAV2 CCM-VZ-HON -FCC ID: RI7LE910SVV2 -IC: 51314-LE9I0SVV2 * Additional certifications in process. ORDERING INFORMATION CCM-ATT-HON - LTE Cellular Communication Module, includes AT&TSI M card and service CCM-VZ-HON - LTE Cellular Communication Module, includes Verizon SIM card and service Antenna and External Hardware: -CELL-ANT3DB: 3dBA gain external/ remote antenna -WA7626-CA: SNAto N Adapter -7626-50HC: 50 ft. antenna cable, low loss -7626-25HC: 25 ft. antenna cable, low loss Note: The CELL-ANT3DB and the WA7626- CA are both required for installing an external antenna along with the 7262- 50HC, 50 ft. antenna cable or 7262-25HC, 25 ft. antenna cable CUSTOMER SUPPLIED EQUIPMENT Mobile Device for LIE Communicator configuration (either iOS or Android) FEATURES AND BENEFITS Connects directly to Honeywell Fire Alarm Control Panels or a network of FACPs Easy connection between the Gateway and CLSS CheckPoint mobile application BlueTooth®mobile pairing for Gateway and cellular module configuration and control capability Panel connection options include Standalone Panel, Networked Panel, and Standalone with Digital Voice Control Provides wireless connection over cellular communication path from the CLSS Gateway to the CLSS Cloud. TECHNICAL SPECIFICATIONS BLt5th" is a regifTF trademark ofitlie Bl&thjS his doDmht is not i'fd to be used for installation purposes. We try to keep our prgduct information to -dte andc!icate. W!annot cover all specific appiLcations[or a nticipate all requirements. All .-. ft Jl s-pec ifications are subjectto change -- withoutce. Electrical Physical Input Voltage: 5VDC • Dimensions: 2.9" (73 mm) Lx 2.8"(72 mm) Power Consumption: 2w (Max. transmit) Wx0.7"(l7 mm) H USB Signaling: USB 2.0, Device • Weight: 1.6 oz (45.36 g) Logic Signaling: 3.3V SIM: 2FF Type, Mini Antennas: Two options: Primary* and Receive Diversity, Internally integrated *The external (remote) antenna option is only for the Primary. RoHS:Yes Specifications CCM-ATT-HON Supported Radio Access 4G LTE Category 1 FDD* Technologies: Bands 2,4,5, 12, and 13 3G UMTS** Bands 2 and 5 Mobile Network Operator. AT&T, North America Approvals: FCC PTCRB AT&T CCM-VZ-HON Supported Radio Access 4G LTE Category 1 FDD Technologies: Bands 2, 4, and 13 3GUMTS Bands 2 and 5 Mobile Network Operator Verizon, North America Approvals: . FCC Verizon * Frequency Division Duplex ** Universal Mobile Telecommunications System ISO 9001 Honeywell International, Inc. BOMMO I MJl!1TIII! www.fire.honeywe[Lcom IUAIITT SYSTEMS HON-62041 I A I 10-20 ©2020 Honeywell International Inc. THE FUTURE IS WHAT WE MAKE IT The door of lifts away for worry free wiring and battery change-out. Mini Battery Cabinet [9 The MBC "BATTERY CABINET" is designed for the profes- sional installation of systems requiring battery storage and meets the requirement of NFPA 72 (1-5.2.9) stand-by battery storage for battery backup. The MBC allows for easy access and maintenance of the bat- teries while also assisting against unnecessary power drain, interference or degeneration of the battery. The unit can be mounted securely to a wall, preventing mechanical injury or damage to other equipment. Standard Features: 16 Gauge (.062 thk.) cold rolled steel White 2" lettering "BATTERY CABINET" Green ground screw with threaded insert Formed lift-a-way hinge Red or Black textured finish CAT 30 keyed door lock Dimensions: 17" wide x 8" high x 4" deep Six 1/2" and 3/4" EMT conduit knockouts located on both sides, top and back NFPA 72 National Electric Code 17p1Y1 IAASj -1 0 0 Iso9001 4 REGIS1ERED \ CQJPANY ADA Space Age Electronics, Inc. 2007 - ED0247 L110247 Rev.B 1/2 mo NFPA Made In U.S.A. Space Age Electronics, Inc. Www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! 8" ISPACEAGE E/ELECTRONICS, INC. Specifications: The MBC Mini Battery Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and finished with a durable red or black textured, heat-resistant baked-on enamel finish. The front cover is engi- neered with a removable formed lift-a-way hinge, displays "BATTERY CABINET" in 2" white screened lettering and includes a high security CAT 30 keyed door lock. The unit comes with a green ground screw with threaded insert. Overall dimensions measure 17" wide by 8" high by 4" deep. Six 1/2" and 3/4" EMT conduit knockouts are located on both sides, top and back. The battery cabinet meets NFPA 72 National Electric Code requirements. Batteries not included. Removable formed 11 lift-a-way hinge Ordering Information: Part # Description SSU00505 MBC Mini Battery Cabinet - Red SSU00506 MBC Mini Battery Cabinet - Black Space Age Electronics, Inc. www.1sae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0247 L110247 Rev.B 2/2 (0) 13.01 Discharge Time VS. Discharge Current (200C) 12.0 150 50.0 0.0 F2orF3 Terminal 00 . 2 46510 00 4060 2 16510 00 I i— minutes —4 +— hours Discharge Time SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20 hour rate ( 0.9A to 10.50V) 18Ah lo hour rate ( 1.8Ato10.50V) 17.1Ah 5 hour rate (3.06Ato10.20V) 15.34 1C (18Ato9.60V) 8.1Ah 3C (54A to 9.60V) 6.3Ah Weight Approx. 13.82Lbs. (6.28kg) Internal Resistance (at 1KHz) 10 m Maximum Discharge Current for 30 seconds: 360A Maximum Discharge Current for 5 seconds : 720A Operating Temperature Range Charge 0°C (32°F ) to 40°C (104°F) Discharge -15°C ( 5°F ) to 50°C (122°F) Storage -15°C (5°F) to 40°C (104°F) Charge Retention (shelf life) at 20°C (68°F) 1 month 92% 3 months 90% 6 months 80% Charging Methods at 20°C ( 68°F) Cycle Use: Charging Voltage 14.4 to 15.OV Maximum Charging Current : 5.4A Standby Use : Float Charging Voltage 13.50 to 13.80V Life expectancy: Cycle Use: 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles Standby Use : 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) DIMENSIONS mm(inch) 12 i-f ;I 3 (FABTOII TAB 50.250) (M5 Bolts) 181±(7.13* 76±(2.991 —-l----'—' u 60O CE 5607.15 Ysl 041 l5V.1SAKtR Pb MI( Batten 1631 South Sinclair Street • Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com Li0 00 Maintenance-Free Rechargeable Sealed Lead-Acid Battery SIGNAUNG INTED ACE-Il j. 9T4EffIR1IX DMENiiiS Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tall and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 722013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). EU ISO 9001 Space Age Electronics, Inc. NFPA COMPANY 800.486.1723 Toll Free Made \,-' 508.485.0966 Local ln\U.S.A. 508.485.4740 Fax Space Age Electronics, Inc. 2013 ED0584 L110641 Rev.A 1/2 No Excuses, Just Solutions! i] - Key Ring Hooks - Business Card Holder 0 /SPACE AGE =ELECTRONICS, INC. Specifications: The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. ' USB Storage Interface 3 U Requires Standard USB-B Connector ---. ..... Pmperty information Minimum Required Documentation (SIG.FUN) Ornyrfp& C.,6Ac.Uon and App,ovJs ... 16.1 System Inethiletion Contreotor: t,00..o o .,o ead.ondoofleOFfl,d.ofl..n eSfl,t,onO.te.nEQSOA#.ObO,ren.O..onn 10. ,enApnes,onona SM. posse 16.5 Ieo0hsrtty sins Jdktion: )Ms 5.000150. ka.M0o.,.O•0000.tr MCI 5. 0 50005 S•CIS?0• 00 O0S0*rS, S000500 .1 S 500.0.00 0.00 0 fr.05, 5000 SMOg 50 0000010. CCI 7 6 6 5,00 70 0 a—n____ P05.05.,,. ____________ 1600P5IS75000000000000005.2070500007 66510762 Eqodpm,nt Infor,oretlosr 060.MC0C.s0.00M. A. - Sp.,.2g.0sOo*.,I. 160005.75.0 05.22055001000 60.4161721 LTI0644 662.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00689 System Record Documents Cabinet RED SSU00690 Custom screening with your Logo EA0315 10 pack door legend sheet This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0584 L110641 Rev.A 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions!