Loading...
HomeMy WebLinkAbout6005 HIDDEN VALLEY RD; 210; FPC2021-0018; Permit17 C ity of I 4 MCI 11I d A asi1f Carlsbad Print Date: 05/01/2025 Job Address: Permit Type: Parcel 4*: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Fi NEW. r1mjt CARLSBAD, CA 92011-4225 Work Class: Fire Sprinklers Track #: Lot 4*: Project 4*: Plan 4*: Construction Type: Orig. Plan Check 4*: Plan Check 4*: Permit No: FPC2021-0018 Status: Closed - Finaled Applied: 02/04/2021 Issued: 02/23/2021 Finaled Close Out: 05/11/2021 Final Inspection: INSPECTOR: Maldonado, Adalmira Cheung, Nathaniel 6005 HIDDEN VALLEY RD. # 210, FIRE-Construction Commercial 2120406600 $126,507.20 Project Title: Description: CROSSINGS SPEC SUITE -SPRINKLER TI (21 HEADS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 m glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is Intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a tire situation or cause it to operate prematurely. Il The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained In compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties herring jurisdiction. Failure to doss may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313. . -. Upright 5.6K, 1/2 In. NPT TY323... Pendant 5.61K, 1/2 in. NPT Technical Data Approvals Refer Is Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)' ma nazi, r, waking pressure at 250 pal 1172 ban OW encore to M. flaring by UndthrtaraLab0,ata- rtmjinitO Discharge Coefficient K=5.6 GPM/pslto 180,6 LPM/bartol Temperature Rating Refer to Table A Finishes Sprinkler. Paler to Table B Recessed Escutcheon: White Coated, Black Coaled. Chrome Plated, or Brass Rated Physical Characteristics Fruwu ............................Bmvzo eaton ......................Brasa/Ccppor Soullea Assembly . . .Stoinlona Stool w/TEFLON Bulb............................... Glans cswpresnlsn Screw ................. amoco flonectcr ......................... Bronmn Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature Is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed In accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval Is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon Is to be used for recessed pendent Installations. Installation The TYCO Series TY-FRB,5.6 K-factor, Upright (1Y313) and Pendent (T-Y323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble Is approximately 1/16 In. (1,6 mm) forthe 135"F (57°C) and 3/32 in. (2.4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or Impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step I. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. lighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 1910 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendant Sprinklers must be Installed In accor- dance with the following Instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fining. Step B. lighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1. apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9.5 to 19.0 Nm). Step C. Alter ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Worldwide Contacts .tyco-flre.com [q Series TY-FRB, 5.6 9-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage TFPIY2 Page 2 of 4 Components: a m 4 Bulb Tewperetare rating is CS Pipe thread connections per ISO 7-1 - Frae - indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression S-ryta is or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2' 7/16' (11,1 mm) RECESSED Assembly 6 - Deflector" DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 7/16 (11,1 mm) NOMINAL MAKE-IN 2 . 2 (34,B mini WRENCH FLATS ,..,.PT** DEFLECTOR 2-7YS'(73,Omrn)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (17313) AND PENDENT (17323) SPRINKLERS 5,6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE WRENCH RECESS llJEY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 1 of 4 AUGUST 2018 TFPI72 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that It controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in fire situation. The owner mast assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather dusteri otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after Installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lout liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devises in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the Install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be Inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify') finish, PIN (specify') Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify') 'Rater to TechnIcal Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8' DIP,. (73,0 tints) 3 FACE OF 2-1/4' DIP,. SPRINKLER Fri-TiNs 5/8° (15,9 mm) FLUSH /8u5/ (9.5o7,9 mm) MOUNTING SURFACE CLOSURE SERIES MOUNTING 1-3/8° )34,9 otto) TY-FRB PLATE 3/4'(19,1 rem) FIGURE 4 SERIES TV-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8°Dlk (73,0 in) FACE OF SPRINKLER 2-1/4° DIP,. FITTING mm) 5/16n1/4' 1/2 (127 I (7,906,4 mm) T-7— MOUNTING ; SURFACE CLOSURE SERIES MOUNTING 1-3/8'(34,9m.) r,'-FRB PLATE 7/8' (22,2nrrn) FIGURE S SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON ) ) ) TFP172 TFPI72 Page 3 of 4 Page 4 of 4 SPRINKLER FINISH (See Note?) TYPE TEMPERATURE BULB LIQuID NATURAL CIE PLATED POLYESTER' FACTOR LOR BRASS 135°F )57'0) Orange UPRIGHT 155-F (68-C) Red and 1.2,3,4, 5,8 175°F (79°C) Yellow PENDENT (TY323) 200-F (93°C) Green 286'F (141°C) Blue 1/2 in. NPT 5.6 __________________________________ ______________ 135°F (57°C) Orange PENDENTRECESSED I 2 3 4 155°F (69°C) Red 175°F (79°C) Yellow RSufL,4.SSd so Green 200°F (93°C) I. Ussta by U-,- LaboratorIes, Inc.. lull as 00(0k Aaspons Sprrnciars. Uetedby Undaroaroarc Laboratorleo. Inc.. for Is, In Caned, (C-UL) 05045 noaporaaspnlnklero. Approrosa by Facto,5 Manual Researcu CorporatIon p.0) as Quits Raspo,,ea Srdflklara. ftpploved by toO Cny of New York u,,dOr MUle 054-Or.E, VdSlepprsvedprordotaas.contactJoflneoflCOflbola. Erotnada. Nortoedands. TeL or.sa.doe.44441Fae 01.544204077/ 0. Appo000d fly 5a I.oma Preoenllo,,florllficollan woeffl ILPCa ten. No. 0045/06) as QuIck 005pnnse Spnnklars. 7. Where Polyester 00,122 sprinlders ore noted to be UI and C-UI Lielad. the aprinklars ore UI and C.uLUatodooCorroslornnoSletantsPrlflklors. Installed elm Style 15 (in In NFl) 5/0 in. Total udlUsbnent Recassad p020lohoon. asepplleabto. U. Inotalled,r,IthStrt, 2011/2 In. lIFT) 1/Tin. TauJ fldlusyrranl noc000aa EscUt2hecn as oppacoble. F,enoa tori Detector 00/f. LIstIngs end app,ore)s apply to oolnrlupaclalOrdsrl. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 _)()(j( - - XXX SPRINKLER SIN FINISH ~105PRIGHT (1/2 ln.NP1) 1V313 ENDENT (1/2 ln.NPT) TY323 a. lla;eut(ol°lo,lsbl-nconooctlan;Iote0ample. N- & Eastern Heanloplrato Sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Ida, Peowsecok Pa/nan, Lanadote, PAlee4elTstnpt005001.215492.olan Øffr Johnson Controls 1 NATURAL BRASS - PURE WHITE )RAL9O1O)° POLYESTER SIGNAL WHITE (RAL9003) POLYESTER - JET BLACK )RAL9005) POLYESTER 9 CHROME PLATED TEMPERATURE RATINGS 135°F (57°C) 155°F (68°C) 175'F (79°C) 200'F (93°C) 286°F (141°C) As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. - 1295 1.650 t900 2.375 l.D.(in) 1.083 1.418 1.654 2.123 Empty welgnt (lb/ft) 1.451 2.070 2.547 3.308 Water Ffllmi Weight (lb/It) 1.860 2.754 3.458 4.842 - MR. 1.00 tOO 1.00 1.00 Pieces per lift 70 51 44 30 lift weight (Ibs) 21 lengths 2.148 2,217 2,353 VpLift (Ibs) 24 lengths 2,084 t 2,454 2,534 2,690 Weight JIM) 25 lengths 2382 2,55? 2,639 2,802 2,481 EYThR1AD 40 ALTEIES: UL listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13, 13R and 14 Industry-leading hydraulic characteristics CRR of 1.0 and greater All pipe NDT weld tested §jEN.XG_ma ker LSTE OTHE2 OVERTS/sERVICES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II" bactetiaL-resistant internal coating Custom Length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems The only maker with EPDs (to help earn LEED points). I Offm NFFU 1w_I- 800.325.4467 salesCa)BuliViaoselndustries.Eum lengths. Other even foot lengths can be furnished to order. - Material: Carbon steel or Stainless Steel Gr 304 Threads: National Coarse (USS), rod threaded complete length. FInIsle Plain orD Zinc Plated (Hot-Dip Galvanized optional) Maximum Temperature: Zinc Plated 450'F, Stainless Steel 650' F Approvals: Complies with MSS SP-58. C) Ordering: Specify rod diameter and length, figure number, name and finish. Note: The acceptability of galvanized coatings at temperatures - above 450'F is at the discretion of the end user. 'If through 2' Size Rounded Edge Design LenoS, Uses APPROVED t 21/1" through r Size 'fjf . It. •ru'.zlnzgusuzuru"r,." .t."'i FIG. 146: DIMENSIONS (IN) • LOADS (LBS) . WEIGHTS (LBS) Rod Situ A Threads per Inch Max Load 65D 'F Weight per Fl. ¼ 20 240 0.12 ¼ 18 730 0.30 ¼ 13 1,350 0.53 11 2,160 0.84 ie 3,230 1.20 "I. - - 4,480 1.70 1 - 5,900 2.30 1% j RING HANGERS Fig. 69 (Formerly Afcon Fig. 300) Adjustable Swivel Ring, Tapped Per NFPA Standards RODS & EYE RODS Fig. 146 (Formerly Afcon Fig. 650) Continuous Threaded Rod Size Range: , through 8 Material: Carbon steel Finhoh Strap is 're-Galvanized Zinc Material, Nut is Zinc Plated. Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 450' F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), and ANSI/MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes '/-` - 8'). Features: - 2" sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil Threads are countersunk so that they cannot become barred or damaged. Knurled swivel nut provides vertical adjustment after piping is in place. Captured swivel nut In the Yf through 6" sizes. The capture is permanent In the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely Out. Ordering: Specify size, figure number and name. Non-captured nut also available upon request. A -o1A Y," through 1' pipe - V/4" through r' pipe 21/,* through 8, pipe - FIG. 69: DIMENSIONS (IN) . LOADS (IBS) • WEIGHT (IBS) Pipe Weight 0 F Width 0.10 0.10 ¼ 2% -::L::J. 5/8 - 0010 2A s -- 1W. -- I Rod ASize$ 411.1. J!i-_ ' 11A 2 0.10 0.11 jY -i 20 'Is 1`16- 0.30 3r%• 1'/ S j ¼ s's. snA, 2% Project DApprozed Address: D*ppmved as noted Contractor DNSt approved Engineer Reniasko: Submittal Date: Moles 1: Notes 2: Size Range: 'If through 1 "f Stocked in six, ten, and twelve foot I6111IM09100110 uulb W Project IDApproved DAmzeod so noted Contractor Not approved Engineer., Remarks: [Submittal Dote: j Notes 1: Notes 2: PH-1.18 oil ULMax Pipe UL Test Minimum FM Max F0, TOO Minimum Wood BX PIN WOOO UL Size, in. Load Wood 13009 Slow h.oaa Thickness, ln hi I 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 X 4 1475 1.5 -8009925 GST25-380 X 4 1500 1.5 X 4 1475 1.5 -8022925 SWG 25-380 X 3-1/2 - 4.* 1500 1.5 X 4 1475 1.5 -8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 X 4 1500 1.5 X 4 1475 1.5 8140957 SHGST20SS X 3 1050 1.5 8142957 SHGST30SS X 4 1500 1.5 UL Max Pipe UL Test Minimum FM Max FM Test Minimum BX PIN STEEL UL Size, in. Load Steel FM Pipe Size Load Steel Thickness in. Thickness, in. 8038957 DSTR I X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 rBX P/N CONCRETE F1 F fax Ff TVA Material Pipe Size Load 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" tv-DeBuMd ay. UL and FM tests were performed in compliance with NFPA-13 Standards. www.itwbuildex.com Fastening requirement: 5 times weight of water filled schedule 40 pipe pIus 250 pounds. 800-284-5339 SSS26 ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1I2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" 1 of 3 HOLE CUT SYSTEM MODEL V.723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com 1. DESCRIPTION VGS" Model V-723 Saddle Let small mechanical tees are available In sizes 1-1/4' through 2-1/2'. The Models V-723 mechanical tees provide an easy take-out of a branch outlet without the need for welding. VGS° Mechanical Tees are manufac- tured at iS09001 certified facilities an are designed to conform to ASTM and other I standards where applicable. Threads are NPT per ANSI B1.20.1. (11 LISTINGS AND APPROVALS cos Guide No. V1ZM Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A538 Grade 65-45-12 Standard black finish Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, adds "0' suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM 02000, AWINA C606. NSF 61 and LAPMO Nuts and Bolts: Zinc plated, Carton Steel conforming to ASTM A183 Grade 2 )UNC nuts and bolts are a silver chromate color and ISO are a gold chromate color) -J Hole Diameter* Dimensions Nominal Size +1.6,-0 7" Soft Size It Torque Weight in (moo) (-0.093,-0)A B C In (moo) In (mm) Lb-Ft (Mm) Lbs (I(ga) In (mm) In (mm) in (mm) 1,25's 0.5 lIe 1.57 3.5 2.2 1.03 U-Bolt 20-22 0.0 (32 015) (30) (49) )89(_ LoOl (42) (3/80) (27-30) 10.411 1.2500.70 1.18 1.97 3.0 2.2 1.83 U-soft 20-22 to 132020) )30( )45) (as) (SO) (42) )3/8a) (27-30) 10.401 1.250 1 1.15 2.04 3.0 2.2 1.73 U-Box 20-22 1.0 (320 25( (30) )52( (05) )58) 1441 13/eel (27-301 )c.45) 1.500,5 1.10 2.54 3,0 2.2 1,70 U-Bolt 20-22 0.9 (400 15) )30) (52) (Be), (56) (46) (3/8e) (27-30) (0.41) 1.500,75 1.18 2.04 3.5 2.2 1,79 U-BoO 20-22 0.9 (40o20) (30) (52) (09) (tO) (48) (3/80) (27-30) 10.411 1.5sf 1.19 2.04 3.5 2.2 1.69 U-8.1t 20-22 0.9 (40 o2OL (30) (52) (90) (58) 143) (3/Sc) 127- 30( (0.41) 200.0 1.10 2.30 3.50 2.2 2.07 U-1210" 20-22 0.0 (500 15) (30) (59) (SB) (50) (53) (3/90) (27-301 (0.41) 200.75 1.18 2.30 3.08 2.2 2.07 U-801t 20-22 0,9 (550 2) (30) 1501 (05) (56) (93) (3/se) (27-30) (0.41) 20 1 1.18 2.30 3.59 2.2 1,97 U-BoO 20-22 1,0 (50025) (30) (59) (SB) ),5O( (50) (3/ee) (27-30) (0.40) 2.500,5 1.15 2.48 4.37 22 222 U-Box 20-32 1.0 (55s 15L (30) (03) (111) (SB) (57) (3/8e) . (27 -30) (0.45) 2.000,75 l.IB 245 4.37 2.2 2.22 U-BoO 20-22 1.0 (85020) (30) (83) IjIl) J,56( (57) (3/Se) )27 -30) (0.45) 2,501 1.18 2.45 4.37 2.2 2.13 U-BoO 20-22 1.0 (e so 25) (30) /03> (111) (50) (541 (3/00) (27-30) (0.45) i-/ole 6/seaters ore sugoeslod W. sew 0/seaters. "T: Take-oat (Center of run to end of pipe to be 0n90908) 2 of 3 HOLE CUT SYSTEM S ms", @YZ I I MODEL V-723 SADDLE LET I MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcstvlkingcorp.com HOLE CUTTING The hole-cal method of pipe preparation Is required when using mechanical tees, mechanical crosses, and saddle-lets. The method of pipe preparation requires the cutting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a torch for cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8' (16 mm) of the hole should be Inspected to ensure a dean smooth surface, free of any Indents- (ions or projections that could affect proper gasket sealing. The area within the 'A' dimension should also be inspected and must be free for dirt, scale or any imperfection that could affect proper seating or assembly of the Oiling. G GOBS Gim)s4t5m1thB ttth, Mechanical Toes Hole Dimensions urfle 1f CTTd on Branch Size Hole r55 Sloe Maximum "A° In (mm) co-/ro/J 10,3/4,1 1l8 temeterAlioWed (85) 1-1/4 3-10 (15, 20,25) I (30)I_(32) INSTALLATION NOTES: - Use a wrench to hold the threaded %Imv (ti BSQtHOBisIlsOBItr £iol)r' nhrllel in p1nrra when installing the sprinkler. Outlet Size 1120T 3i4-'1-11- Tighten the nuts evenly. K15 K-factor of Saddle-Lets 612 615 Do not Install sprinkler directly Into Saddle-Let with 1' outlet. "Oil Hole Gasket Threaded outlet Nuts Sprinkler Figure 1: V-723 Saddle-Let Installation Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 Form No. F_110515 16.12.08 Rev 16.1 (Added K-factor limit table and 110w data) 3 of 3 T HOLE CU SYSTEM ''•] 065", i1O1!JL!IiY [ I MODEL V.723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techavcsvikingcorp.com 6. FLOW DATA g85 5I6Ib SB - _ Nominal Inlet Size I Inches Nominal Outlet Size Model Inches Equlvsont1.fl9th7 ' Feet V-723 125 1 6 27 V.72.3 1.5 1 6 27 V-723 2 1 6- 27 V-723 2.5 1 3 38 ) Flow test data has show,, that the total head loss between point A and B for the fittings can be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Formulas forty Values: pQO Vulroro: QFlow (GPM) Pressure Drop (psi) Q=C0 x p C Flow Coefficient Porn, No. F_110515 18.12.08 Rev 16.1 Replaces Form No, F110515 Rev 15.1 (Added K-factor limit table and flow data)