Loading...
HomeMy WebLinkAbout4285 HILLSIDE DR; ; FPR2022-0031; Permit41ri1il I iis] 1rI c ity of Carlsbad F.i)[eiBeJimi1t Print Date: 05/01/2025 Job Address: 4285 HILLSIDE DR, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2061601500 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2022-0031 Applied: 10/26/2022 Issued: 11/30/2022 Finated Close Out: 04/27/2023 Final Inspection: INSPECTOR: Salcedo, Felix Cheung, Nathaniel Status: Closed - Finaled Single Family Fire Sprinkl Project Title: Description: GIBSON RESIDENCE -NEW 13D SPRINKLER SYSTEM FOR NEW SFR (56 HEADS) FPContractor: RIOS FIRE PROTECTION INC P0 BOX 1546 EL CAJON, CA 92022-1546 (619) 212-0956 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $148.00 FIRE NFPA 13D Single Family System (Plan Review) $292.00 FIRE Reinspection (per Inspection) $228.00 Total Fees: $668.00 Total Payments To Date: $668.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov tell October 24, 2022 HYDRAULIC CALCULATIONS FOR GIBSON RESIDENCE FILE NUMBER: 01-260 OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/196 sq.ft. AREA OF APPLICATION: BATH COVERAGE OF SPRINKLER: 14'X 14" NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 22.5 gpm TOTAL WATER REQUIRED (including hose): 27.5 gpm FLOW AND PRESSURE (@ BOR): 22.5 gpm @ 43.5 psi SPRINKLER ORIFICE SIZE: 1/2' inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION INC. DESIGNER: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD WATER DEPT. CONTACT: JENNIFER DATE: 10/24/22 STATIC: 110 psi P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/24/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\GIBSON RESIDENCE.SDF JOB TITLE: GIBSON RESIDENCE WATER SUPPLY ANALYSIS Static: 100.00 psi Resid: 99.00 psi Flow: 500.0 gpm 120.0 LEGEND 100 1 gAvailable pressure 100.00 psi @ 27.5 gpm G A U 80. 2 0 G E 2 gRequired pressure 83.99 psi @ 27.5 gpm P R 60.0 E S S U 40.0 R E Source Supply Curve System Demand Curve P 20.0 5 i -14.7 10 015 0 200 250 300 350 400 450 500 FLOW (GEM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/24/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\GIBSON RESIDENCE.SDF JOB TILLE: GIBSON RESIDENCE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 100.0 99.0 500.0 100.0 27.5 84.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 27.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 22.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 17 15.0 K= 3.00 13.4 11.0 16 15.0 - - - - 14.8 - - - 15 15.0 K= 3.00 14.7 11.5 14 15.0 - - - - 19.3 - - - 13 15.0 - - - - 25.6 - - - 12 15.0 - - - - 34.6 - - - 11 15.0 - - - - 37.9 - - - 10 15.0 - - - - 39.8 - - - 9 9.0 HOSE STREAM 43.5 5.0 8 5.0 - - - - 49.4 - - - 7 3.0 - - - - 52.4 - - - 6 5.0 - - - - 53.1 - - - 5 5.0 - - - - 65.1 - - - 4 3.0 - - - - 67.5 - - - 3 3.0 - - - - 69.2 - - - 2 3.0 - - - - 73.2 - - - SOURCE 0.0 SOURCE 84.0 27.5 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/24/2022 C:\USERS\CANDI\ONEDRI\7E\DESKTOP\GIBSON RESIDENCE.SDF JOB TITLE: GIBSON RESIDENCE NFPA5 PIPE DATA Pipe Tag K-tao Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 7.0 40.00 150 10.7 SOURCE 0.0 84.0 27.5 3 1.000 7.00 1.3 2 3.0 73.2 27.5 0.995 47.00 0.201 9.4 Pipe: 2 0.0 Fixed Pressure Loss Device 2 3.0 73.2 27.5 4 4.0 psi, 27.5 gpm 3 3.0 69.2 27.5 Pipe: 3 0.0 0.0 7.0 3.00 150 1.7 3 3.0 69.2 27.5 5 1.000 7.00 -0.0 4 3.0 67.5 27.5 1.025 10.00 0.174 1.7 Pipe: 4 0.0 0.0 7.0 2.00 150 2.4 4 3.0 67.5 27.5 6 1.000 7.00 0.9 5 5.0 65.1 27.5 1.025 9.00 0.174 1.6 Pipe: 5 0.0 Fixed Pressure Loss Device 5 5.0 65.1 27.5 7 12.0 psi, 27.5 gpm 6 5.0 53.1 27.5 Pipe: 6 0.0 0.0 7.0 2.00 150 0.7 6 5.0 53.1 27.5 8 1.000 7.00 -0.9 7 3.0 52.4 27.5 1.025 9.00 0.174 1.6 Pipe: 7 0.0 0.0 5.0 50.00 150 3.0 7 3.0 52.4 27.5 9 1.250 5.00 0.9 8 5.0 49.4 27.5 1.394 55.00 0.039 2.1 Pipe: 8 H.S. 5.0 Disch 19.0 5.00 150 5.9 8 5.0 49.4 22.5 10 1.000 19.00 1.7 9 9.0 43.5 27.5 1.025 24.00 0.174 4.2 Pipe: 9 0.0 0.0 7.0 6.00 150 3.7 9 9.0 43.5 22.5 11 1.000 7.00 2.6 10 15.0 39.8 22.5 1.101 13.00 0.085 1.1 Pipe: 10 0.0 12.9 14 15.0 7.00 150 1.9 10 15.0 39.8 9.6 12 1.000 15.00 -0.0 11 15.0 37.9 22.5 1.101 22.00 0.085 1.9 Pipe: 11 0.0 0.0 24.0 37.00 150 3.3 11 15.0 37.9 9.6 13 0.750 24.00 -0.0 12 15.0 34.6 9.6 0.874 61.00 0.054 3.3 Pipe: 12 0.0 0.0 74.0 92.00 150 9.0 12 15.0 34.6 9.6 15 0.750 74.00 -0.0 13 15.0 25.6 9.6 0.874 166.00 0.054 9.0 Pipe: 13 3.00 11.5 Disch 111.0 91.00 150 10.9 13 15.0 25.6 -1.9 0.750 111.00 -0.0 15 15.0 14.7 9.6 0.874 202.00 0.054 10.9 Nc SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/24/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\GIBSON RESIDENCE.SDF JOB TITLE: GIBSON RESIDENCE Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 99.0 101.00 150 18.6 11 15.0 37.9 12.9 16 0.750 99.00 -0.0 14 15.0 19.3 12.9 0.874 200.00 0.093 18.6 Pipe: 15 0.0 11.0 17 22.0 27.00 150 4.6 14 15.0 19.3 1.9 15 0.750 22.00 -0.0 16 15.0 14.8 12.9 0.874 49.00 0.093 4.6 Pipe: 16 3.00 11.5 Disch 13.0 6.00 150 0.1 16 15.0 14.8 -9.6 0.750 13.00 -0.0 15 15.0 14.7 1.9 0.874 19.00 0.003 0.1 Pipe: 17 3.00 11.0 Disch 15.0 4.00 150 1.3 16 15.0 14.8 0.0 0.750 15.00 -0.0 17 15.0 13.4 11.0 0.874 19.00 0.069 1.3 NOTES (HASS) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64916306 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.056 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.4 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 99.99 psi with a flow of 30.64 gpm. PIPE FITTINGS TABLE User Pipe Table Name: CPVC N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/24/2022 C:\USERS\CANDI\ONEDRI\7E\DESKTQP\GIBSON RESIDENCE.SDF JOB TITLE: GIBSON RESIDENCE PAGE: A MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C L B D N E45 TEE TRUN COUPLN L90 BRANCH G -------------------------------------------------------- F 0.874 1.00 3.00 1.00 1.00 7.00 3.00 0.00 0.00 0.00 0.00 1.101 1.00 5.00 1.00 2.00 7.00 4.00 0.00 0.00 0.00 0.00 PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) H T L C B G A D N Eli -------------------------------------------------------- Tee LngEfl ChkVlv BfyVlv GatViv AlmChk DPViv NPTee F45Ell 0.995 1.55 3.87 1.55 3.87 4.64 0.77 7.73 1.55 3.87 0.77 1.025 1.79 4.47 1.79 4.47 5.36 0.89 8.93 1.79 4.47 0.89 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 1.58 K-Factor: 3.0 o SIN: 5S8361 Residential Lead Free Flat Concealed Sprinkler, Pendent C @US LISTED I NSF/ANSI/CAN 61 & 3121 ED Ce;, " GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 3.0 (43.2 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. www.senjusprinkler.com Page 1 of 8 Document No.U03956A• 02-08-2021 NPT 112 2-1116 (052mm) Marking Lot No. Year of Manufacture SIN. S58361 -K-Factor. K3.0 I-TemperatureRatin272'C J -UL Mark Control No: 6P37 -ALS Mark: NSF 61/372 RES SPKR Body (Copper Alloy) ) Deflector (Phosphorus Bronze) (5) Gasket (PIPE) 2-518" (068mm( (4) Fusible Metal (Solder) 3-114" (083mm) (s) Heat Collector (Copper) or 2-518" square (088mm> ( Cover Plate Assembly Figure 1: Model RC-RES K = 3.0 / Cover Plate Sprinkler (lop View) (Bottom View) rking (Deflector) SIN: SS8361 K-Paulo,: K3.0 Temperature Ruling: 162"F172 'C or 205 "P186 "C UL Mark Figure 1.1: Marking (Color Code) WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. TECHNICAL DATA Approvals: ° cULus Listed UL-EU Listed (162°F (72°C) only) NSF/ANSI/CAN 61, NSF/ANSI 372 Sprinkler Identification Number (SIN): S58361 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficient (Nominal K-Factor): K = 3.0 GPM/psi112 (43.2 LPM/barv2) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 205°F (96°C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: ° Standard Finishes: White, Ivory, Beige, Brown, Black, Nickel, Wood Grain ° Custom Finishes: Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1.1 www.senjusprinkler.com Page 2 of 8 Document No,U03956A. 02-08-2021 OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) ,., Normal condition Cover Plate Operation Sprinkler Operation Water Discharge Figure 2: Operation Process (For illustrative purposes only) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Notes Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler, consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13D, 13R, or 13) must be kept as few as possible while observing all guidelines relating to obstructions and spacing. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. www.senjusprinkler.com Page 3 of 8 Document No.1-103956A 02-08-2021 Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 130 and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 130 or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 130 or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. wwwsenjusprinklercom Page 40f8 Document NoU03956A 02082021 Table A. NFPA 13D & 13R Wet Pipe Hydraulic Design Criteria for Model SS8361 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Maximum Ordinary Temperature Intermediate Temperature Coverage Spacing Rating 162F (72CC) Rating 205F (96'C) Deflector to Installation Minimum Area' Ft. x Ft. Ft. Ceiling Type Spacing Ft. (m) Flow(b)GPM Pressure(b) Flow(b)GPM Pressure(b) (m x m) (m) (1PM) PSI (bar) (1PM) PSI (bar) Smooth Ceilings 3/8 12 X 12 12 9 9.0 9 9.0 to 7/8 Inches. (3.7 x 3.7) (3.7) (34.1) (0.62) (34.1) (0.62) Beamed Ceilings per NFPA 130, Concealed 8 13Ror13. (2.4) Installed in 14 x 14 14 11 13.4 11 13.4 beam 3/8 to (4.3x4.3) (4,3) (41.6) (0.92) (41.6) (0.92) 7/8 inches below bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ftlbs (9.5 to 19.0 N.m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Removal Tool for RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. www.senjusprinkler.com Page 5 of 8 Document No.U03956A 02-08-2021 Installation Steps Step 1: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2: With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3: If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do Not Ave. 1/4" (6.4mm) Over-i r — - Vertical Ad!ustment -"- Cq a Mounting Surface 2-3I8 (0 60mm) Ceiling Hole Diameter Correct Incorrect Figure 3: Installation Figure 4: Ratchet & Socket Step 4: Use the Cap Removal Tool for RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Sprinkler Head Hook Up "Y U Protective Cap - . -. / L Cap Removal Toot _ LI Pull down Step 1 Step 2 Steo 3 Figure 5: Protective Cap Removal (: www.senjusprinkler.com Page 6 of 8 Document No.U03956A• 02-08-202 Wit Cup MUfl.8flP I Deflector/ .-t 2-5)8? )068rrno) or 3-1I4 (083mm) or 2-5)8? sauare (Q68mm) Figure 6: Installation (Cover Plate Assembly) JJ - Incorrect Correct Incorrect Figure 7: Installation (Correct and Incorrect) CARE & MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. Notes Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non- factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. www.senjusprinkler.com Page 7 of 8 Document No.U03956A• 02-08-2021 Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. LIMITED WARRANTY For details of warranty, refer to Sales Contract. ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES SIN: SS8361, Residential Flat Concealed Sprinkler, Pendent, K3.0, Temperature: 162°F (72°C) or 205°F (96°C) Cover Plate Assembly 2-5/8 inch (p68mm) or 3-1/4 inch (c83mm) or 2-5/8 inch square (:168mm), Order separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. I m White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F - - - - - - 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - - 0 0 3-1/4" Round, 162°F 0 0 0 0 0 - - 0 0 0 2-5/8" Square, 162°F 0 - - - - - - - 0 0 Tools & Accessories Socket NR-H for use with a 3/8" drive ratchet (not included) Socket NR-H Plastic for use with a 1/2" drive ratchet (not included) Cap Removal Tool for RC Cover Plate Installation Tool www.senjusprinkler.com Page 8 of 8 Document No.U03956A 02-08-2021 Worldwide www.tyco-fire.com Contacts RAND RESPOMSE Series LFIIII Residential Sprinklers 4.9 ff(-factor Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are deco- rative, fast response, frangible bulb sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-family dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 130, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. 1LJI The Series LFlI Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan- dards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler fldentiflca ion £5umber (SllEki) TY2234 Page 1 of 6 APRIL 2013 TFP400 TFP400 Page 2 of 6 7/16 (11,1 mm) 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 1 - Frame 2 -Button MAKE-IN SURFACE 3 - Sealing Assembly 4 - Bulb 1 5 - Compression 2 2i14. Screw 6 - Deflector * (57,2 mm) 4 1-5/8" (41,3 mm) * Temperature 5 rating is indicated on 6* Deflector. 2-7/8" DIA. (73,0 mm) cii!H WRENCH `QW) STYLE 20 FLATS RECESSED ESCUTCHEON CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. (57,2 mm) 1/4(6,4mm) MOUNTING PLATE 1/8" (3,2 mm) 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass Pure or Signal White Chrome Plated Physical Characteristics Frame ....................Brass Button ...................Copper Sealing Assembly ........Beryllium Nickel w/TEFLON Bulb (3 mm) ................Glass Compression Screw ........Bronze Deflector .................Bronze Ejection Spring ......Stainless Steel 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING t \ - MOUNTING SURFACE CLOSURE TY2234 FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) / ENCH RECESS (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Discharge Coefficient K=4.9 GPM/psi112 (70,6 LPM/bar112) TFP400 Page 3 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a func- tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli- cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). llnstallllation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor- dance with this section: General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. (Continued on Page 5) TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Max. Coverage Ordinary Temp. Rating Intermediate Temp. Rating Area (a) 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (mx m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 41nches 14x14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) 1 (0,48) Beamed Recessed using Style 20 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 x 18 17 12.0 17 12.0 (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating ________________________ Intermediate Temp. Rating Minimum Covera9e Area (a 155°F (68°C) 175°F (79°C) Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure (m x m) Ceiling Type Ft. GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 14 X 14 (4,3 x 4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) 4 inches Beamed Recessed using Style 20 16x16 15 9.4 15 9.4 Ceilings per Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, cr13 (2,4) 18 x 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFIl Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. ©are and flYilaintenance The TYCO RAPID RESPONSE Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the Sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other- wise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. rdering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (TY2234), K=4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 155°F (68°C) Natural Brass ..............P/N 51-201-1-155 Pure White (RAL 9010)° ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated .............P/N 51-201-9-155 175°11F (79°C) Natural Brass ..............P/N 51-201-1-175 Pure White (RAL 9010)° ......P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated .............P/N 51-201-9-175 *Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). *Refer to Technical Data Sheet TFP77O. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tijco TEFLON is trademark of The DuPont Corporation. Page 1 of 6 I MICROFAST® QUICK [ ~\M6 I RESPONSE PENDENT I SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 CB LPCB Approved: Certificate 096e106 10 VLI WARNING: Cancer and Reproductive Harm- ww.P65Warnings.ca.gov CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 "F (57 "C) = A, 155 °F (68 "C) = B, 175 "F (79 "C) = D, 200 "F (93 °C) = E, 286 "F (141 °C) = G Form No. F_033314 18.10.11 Rev 18.1.P65 Replaces Form No. F_033314 Rev 18.1 (Added P65 Warning.) Page '2 of 6 MICROFAST® QUICK 1J@XBLXi\ RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 00) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/13 (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_.051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler ___ :- Wrench Flat Clip l ,9• Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F033314 18.10.11 Rev 18.1.P65 Page 3 of 6 I RESPONSE PENDENT 1 MICROFAST QUICK SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Temperature Sprinkler Momma! Maximum Ambient Classification Temperature Rating Ceiling Temperature' Bulb I Color Ordinary 135 °F (57 00) 100 °F (38 00) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 00) 150 °F (65 00) Yellow Intermediate 200 °F (93 00) 150 °F (65 00) Green High 286 °F (141 00) 225 °F (107 00) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 00) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers A 1/2" ratchet is required ** (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 18.10.11 Rev 18.1.P65 Page4 of 6 MICROFAST® QUICK i1Jb1A RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) peratute KEY The Viking Microfast Quick Response F,3Tl Pendent Sprinkler VK302 inish Escutcheon (iapIicabl) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN I Stye K-Factor Length (Refer also to Design Criteria.) Number' NPT ____________ BSP U.S. metric' Inches mm cULus' VdS LPCB ( ( 7 • 12979 VK302 Pendent 1/2" 15 mm 56 80.6 2-1/4 58 A1Z,BIY,D2,C2X Al A1Z,B1Y D1Z,CIY 01W -- 19780 VK302 Pendent 1/2" -- 6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15 mm 1 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 06662B VK302 Pendent 1/2" 15 mm 56 80.6 2-1/4 58 A1Z, B1'r D2, C2X -- -- -- -- 18021 VK302 Pendent 1/2" 15 mm 56 80.6 2-1/4 58 A1X,B1Y Al A1X,B1Y D1X,01Y7 D1W -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 "C), 155 OF (68 "C), 175 OF 1 - Brass, Chrome, White W- Recessed with the Model F-i Adjustable Escutcheon only (79 "0), 200 OF (93 "C), 286 OF (141 "0) Polyesters-6, Black Polyes- X - Standard surface-mounted escutcheon or the B - 135 OF (57 "C), 155 OF (68 "C), 175 OF ter-' Viking Micromatic® Model E-1 Recessed Escutcheon (79 "C), and 200 OF (93 "C) 2 - ENT' Y - Standard surface-mounted escutcheon or the C - 155 OF (68 "C), 175 OF (79 "C), and 3-Chrome Viking Wrofasfl Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- 200 OF (93 "C) matic8 Model E-1, E-2, or E-3 Recessed Escutcheon 0-155 OF (68 "C), 175 OF (79 "0), 200 OF Z- Standard surface-mounted escutcheon or the (93 "0), 286 OF (141 "C) Viking Microfast5 Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart I above) cULus Listing Requirements: The Viking Microfasta Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No, F033314 18.10.11 Rev 18.1.P65 Page 5 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FJ The Viking Microfast Quick Resprnse - Pendent Sprinkler VK302 AIX4— Csc.iLheon (l Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric' Irches 1 mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the 135 °F(57 °C), 155°F (68 °C), 175°F (79 °C), 200 °F Viking Micromatic® Model E-i Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1 -Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfast Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155 °F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedu e. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may te in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer ,,- Chart 2ab0ve) FM Approval Requirements: The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation recuirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation quidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 18.10.11 Rev 18.1.P65 Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum (51 mm) Max. -1/8" 9 mm) Mm. Pae'6 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2 (15 mm) 1. - 2-1/2" (64 mm) maximum NPT\ _ ___ (57 mm) 45 mm) (5mm) Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8" ,• (54 mm) nn - 1-3/4" II (45 mm) Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 18.10.11 Rev 18.1.P65 Replaces Form No. F_033314 Rev 18.1 (Added P65 Warning.)