Loading...
HomeMy WebLinkAbout970 GRAND AVE; ; FPR2023-0003; PermitE1 i IIi1E1 FTi FiTIaiimiit Print Date: 04/21/2025 Job Address: 970 GRAND AVE, CARLSBAD, CA 92008-1811 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel 4*: 0 Track #: Valuation: $0.00 Lot 4*: Occupancy Group: Project 4*: #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Plan Check 4*: (ity of Carlsbad Permit No: FPR2023-0003 Status: Closed - Finaled Applied: 01/11/2023 Issued: 04/19/2023 Finaled Close Out: 11/07/2024 Final Inspection: INSPECTOR: Robinson, Jarrod Salcedo, Felix Project Title: Description: GRAND WEST -BLDG A -INSTALL NEW FIRE ALARM SYSTEM (CONVENTIONAL-NOT ADDRESSABLE, NEW CONSTRUCTION, 2 BL (A & B), 3 UNITS EACH, 3 STORIES, 45 DEVICES) Applicant: FPContractor: SAUL PORTILLA SYMONS FIRE PROTECTION INC 9475 CHESAPEAKE DR 9475 CHESAPEAKE DR SAN DIEGO, CA 92123-1336 SAN DIEGO, CA 92123-1336 (619) 588-6364 x115 (619) 588-6364 FEE AMOUNT FIRE New Alarm System $1,499.00 Total Fees: $1,499.00 Total Payments To Date: $1,499.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Pr,gg Z4hIZ$A ES FD<Z> Ni S I \/ E 0 FZ ES CD LI IR C E F Li L 0 ULI.I_ Ff K 2O2- - cc3 22 - OcDt?:, " I i MrU 1 ~ - M%, ('% i I M, VIIIIIII)IMMr, Ft-~l=%Mti.W.Rw 9475 Chesapeake Drive San Diego, CA 92064 G (619) 588-6364 ' Fax (619) 588-6805 '' CA Lic. #682025 LI S Fp () NJ S I \..' E * rR ES C) U I C E F Li L 0 Li . L. KE TABLE OF CONTENTS - FIRE ALARM SYSTEM SUBMITTAL 1. FIRE ALARM I INTERSTATE 2 POTTER 3 POTTER 4 SILENT KNIGHT 5 SPACE AGE 6 SYSTEM SENSOR 7 SYSTEM SENSOR 8 TELGUARD FIRE ALARM BATTERIES 7AH - 12V FIRE ALARM CONTROL PANEL TELEPHONE ALARM COMMUNICATOR CARD FIRE ALARM PULL STATION (CONVENTIONAL) FIRE ALARM DOCUMENT CABINET FIRE ALARM SMOKE DETECTOR (CONVENTIONAL) FIRE ALARM WALL MOUNTED-LOW FREQUENCY HORN FIRE ALARM CELLULAR DIALER SLA-1075 PFC-4064 LID-2000 PS-SA ACE-11 2W-B HWL-LF TG-7FS 9475 Chesapeake Drive <> San Diego, CA 92064 (>(619) 588-6364 0 Fax (619) 588-6805 *CA Lic. #682025 /If5MERj7EI• 7ES eneaO Purpose Outrageously Dependable! The Power of a Perfect Fit Interstate's SLA battery family powers more than devices. They empower the people who use them-and choose them. SLA0826 4V 4.5 Ah 1.89 2.07 3.70 3.94 Fl SLA0833 4V 8 A 3.58 1.97 3.98 3.98 F2 SLA0836 4V 10Ah 4.02 1.97 3.70 3.94 F2 SLA0855 6V 1.1 Ah 2.01 1.65 2.01 2.24 Fl SLA0865 6V 1.2 Ah 3.82 0.98 2.05 2.24 Fl SLA0184 6V 2.0 Ah 1.69 1.46 2.99 2.99 Fl SLA0902 6V 2.8 Ah 2.60 1.30 3.82 4.06 Fl SLA0885 6V 3.2 Ah 5.28 1.34 2.36 2.60 Fl SLA0905 6V 4.5 Ah 2.76 1.85 4.02 4.17 Fl SLA0906 6V 5 Ah 2.64 2.64 3.78 3.98 Fl SLA0916 6V 5 A 2.64 2.64 3.82 4.65 SPR SLA0935 6V 7 Ah 3.86 2.20 4.02 4.02 Fl SLA0925 6V 7 A 5.94 1.34 3.70 3.94 Fl SLA0945 6V 9 A 3.86 2.20 4.65 4.72 Fl SLA0955 6V 10Ah 5.94 1.97 3.70 3.90 Fl SLA0959 6V 12 Ah 5.94 1.97 3.70 3.90 F2 SLA0961 6V 12Ah 5.94 1.97 3.70 3.90 Fl SLA0986 6V 20 Ah 6.18 3.27 4.92 4.92 NB SLA0993 6V 42 Ah 6.38 3.46 6.42 6.69 F2 SLA0994 6V 42 Ah 6.38 3.46 6.42 6.85 NB SLA0988 8V 3.2 Ah 5.28 1.42 2.48 2.72 Fl SLA1000 12V 700 mAh 3.78 0.98 2.44 2.44 Plug SLA1005 12V 1.3 Ah 3.82 1.69 2.09 2.28 Fl SLA0218 12V 2 A 2.76 1.89 3.86 4.09 Fl SLA1020 12V 2Ah 5.91 0.79 3.54 3.54 Fl iik SY2iIj jix1 SLA1016 12V 2.3Ah 7.01 1.38 2.36 2.60 Fl SLA1015 12V 2.3Ah 7.01 1.34 2.36 2.36 Fl SLA1022 12V 2.9Ah 3.11 2.20 3.90 4.21 Fl SLA0077 12V 2.9Ah 3.11 2.20 3.90 4.13 Fl SLA1 042 12V 3 Ah 5.28 2.64 2.36 2.60 F2 SLA1035 12V 3.5Ah 5.28 2.64 2.36 2.60 Fl SLA1041 12V 3.5Ah 5.28 2.64 2.36 2.60 Fl SLA1055 12V 5 Ah 3.54 2.76 3.98 4.21 Fl SLA1056 12V 5 Ah 3.54 2.76 3.94 4.21 F2 SLA1 075 ( 2V ä Ah 594 ( 56' c3 70" 3 94' Fl SLA1079 12V 8 Ah 5.94 2.56 3.70 3.94 F2 SLA1080 12V 7.5Ah 5.94 2.56 3.70 3.90 F2 SLA1097 12V 10Ah 5.94 2.56 4.37 4.61 F2 SLA1104 12V 12 5.94 3.86 3.66 3.86 F2 SLA1105 12V 12 5.94 3.86 3.66 3.86 Fl SLA1098 12V 12 5.94 3.86 3.66 4.09 NB SLA1116 12V 18 7.13 2.99 6.57 6.57 NB SLA1115 12V 18 7.13 2.99 6.57 6.57 F2 SLA1146 12V 26 6.50 6.89 4.88 4.88 NB SLA1150 12V 30 6.50 4.88 6.89 6.89 NB SLA1156 12V 35 7.72 5.12 6.22 6.65 INS SLA1155 12V 35 7.76 5.16 6.26 7.09 Flag SLA1161 12V 44 7.76 6.50 6.69 6.69 INS SLA1165 12V 55 Ah 9.02 5.43 8.07 8.90 Flag SLA1160 12V 55 Ah 9.02 5.43 8.27 9.25 NB - Reversed SLA1180 12V 65 Ah 13.70 6.61 7.01 7.01 INS 5LA1175 12V 75 Ah 10.20 6.61 8.35 8.98 Flag SLA1185 12V 100Ah 12.09 6.61 8.19 9.06 Flag SLA1189 12V 100Ah 12.09 6.61 8.19 8.43 INS ©2019 Interstate Batteries I ABC-985 ®us LISTED (DPOTTER The Symbol of Protection Conventional Fire Alarm Control Panel 0 Features 6 Programmable Initiating Device Circuits System is expandable to 192 input circuits using the IDC-6 expansion module 5.0 Amp Power Supply 4 Notification Circuit rated at 3.0 Amps Strobe Synchronization for (lentex, AMSECO, System Sensor and Cooper/Wheelock One programmable auxiliary output rated at 1.0 A 4 x 20 LCD display with system LEDs for clear system status P-Link RS-485 bus supports 31 system accessories Built-in Ethernet Connection with listed IP Communicator Ability to E-mail system status, reports and system configuration Service Reminder E-mails Description The PFC-4064 Conventional Fire Panel is a compact, expandable panel designed to monitor all facets of a fire alarm system and communicate the status to a monitoring station. The PFC4064 panel is a listed and approved microprocessor based conventional fire panel and complies with UL-864, NFPA-70, and NFPA-72. The panel is provided with six (6) inputs and four (4) 24VDC, 3.0 Amp Notification Appliance Circuits (NAC) with strobe synchronization. The 5.0 Amp power supply provides ample power to meet any jurisdictions requirements and will charge up to two (2)55 amp/hour batteries. In addition, the panel has the Potter P-Link for connection to system accessories. The panel also has a 1.0 Amp auxiliary power output for controlling ancillary fire alarm functions. The control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two (2)7 AH or two (2) 12 AH batteries. The display is an eighty (80) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history buffer for past events. The key pad allows navigation into the system menu, limited programming and system control. The condition and events on the panel are clearly displayed to allow the user and installer to determine the system status. The panel will support up to thirty-one (3 1) system accessories. Technical Specifications Dimensions 18 1/2" H x 14 1/4 W 43/4" D Enclosure 18 gauge cold rolled steel with removable locked door with Lexan viewing window AC Mains 5.0 amp@ 120 VAC 60 Hz 2.0 amp @ 240 VAC 50 Hz Battery 70 mA Standby 235 mAAlarm Temperature and Humidity 32° to 120° (0°C to 49°C) with a maximum Range humidity of 93% non-condensing. Standards NFPA 70,72 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830139- REV E • 9/19 PAGE 10F5 POTTER FC4064 The Symbol of Protection Conventional Fire Alarm Control Panel 2-Wire Smoke Detector Compatibility Detector Model -7 Identifier Base Model Identifier SYSTEM SENSOR (Brk) (Max. No. Of Detectors Per Zone Is 20) 1400 A N/A N/A 2400 A N/A N/A 2400TH A N/A N/A 2W-B A N/A N/A 2WT-B A N/A N/A DETECTION SYSTEM (Max. No. Of Detectors Per Zone Is 25) DS250 A MB2W/MB2WL A DS250TH A M32W/MB2WL A ESL (Max. No. Of Detectors Per Zone Is 25) 611U Slo 601U SOO 611UD Slo 601U SOO 611UT Slo 601U SOO 612U Slo 601U SOO 612UD Slo 601U SOO 613U5 Slo 601U 500 6I1UD Slo 609U10 SOO 612UD Slo 609U10 SOO 425C S1O N/A N/A 425CT S1O N/A N/A HOC HIKI (Max. No. Of Detectors Per Zone Is 25) SLR-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 NS6-220 HB-3 SLR-24H HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 SJJ-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830139-REVE • 9/19 PAGE 2OFS (DPOTTIER The Symbol of Protection Conventional Fire Alarm Control Panel Detector Model Identifier Base Model Identifier FENWAL (Max. No. Of Detectors Per Zone Is 25) CPD-7051 I51FE1 2-WIRE FE51A PSD-7 155 P55FE1 2WRLT FE52A PSD-7156 P56FE1 2WRB FE55A All of the above Fenwal detectors and bases can be used in any combination. Retrofit Base Adaptor 70-501000-003, Identifier MAFE1 (for series 70-201000 Bases, Models -001, -002,-003, and -005). Duct Housing with Detector Base DH-51, Identifier DH22FE5 (for CPD-7051 and PSD-7 155 detectors only). POTTER (Max. No. Of Detectors Per Zone Is 25) CPS-24 HD-3 (HOCHIKI) SB46 IIB-4 (HOCHIKI) SB-93 HB-3 (HOCIIIKI) PS-24H HD-3 (HOCHTKI) SB46 HB-71 (HOCHIKI) HB-54 (HOCHIKI) IS-24 HD-3 (HOCHIKI) SB46 HB-71 (HOCHIXI) HB-54 (HOCHIKI) NOTE: If using a mix of System Sensor and other smoke detectors, a maximum of 20 detectors shall be permitted. 0 Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830139- REV E • 9/19 PAGE 3OF5 (DPOTTER The Symbol of Protection Conventional Fire Alarm Control Panel User Interface The FIB-1000, FCB-1 000 and the SPG-1000 may be installed in the The fire alarm control panel has a 4 x 20 LCD display to provide stacker bracket or ordered with the optional rack mount enclosure. information to the system status. The keypad has navigation keys MC-1000 Multi-Connect allows up to sixty-three panels to share a to allow manipulation of the Menu on board the panel. The panel is single reporting technology. shipped standard with the following LEDs: AE-2 - Two card expansion cabinet. AC Power - Green Alarm-Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The PFC-4064 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 31 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: LDC-6 - Initiating device circuit expander, provides an additional six (6) inputs. RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) —16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. CA-4064 - Class A convertor that converts the NACs and P-Link connection. UD-2000 - UL listed, Dual line telephone alarm communicator. DRY-SO - LED driver expander, used to connect up to 50 LEDs in a graphic display. FCB-1 000— Fire communication bridge, provides remote mounting of the Ethernet connection. FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required). RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC. SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer. AE-8 - Eight card expansion cabinet. AE-14 - Fourteen card expansion cabinet. Ethernet/I.P. Connection The PFC4064 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard ifi IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830139- REV E • 9/19 PAGE 4OF5 C U LEFT SIDE a 0 a 0 RIGHT SIDE (DPOTTER PFC464 The Symbol of Protection Conventional Fire Alarm Control Panel Dimensions 147W' I 14.48" I Ia 00001 TOP 4.63" 3.95" DEPTH C BOTTOM 1 Ordering Information Model Description Stock No. PFC-4064 Fire Alarm Control Panel 3992360 Replacement Board 3992363 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830139- REV E • 9/19 PAGE 5 OF 5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM LISTI NG SERVICE LISTING No. 7165-0328:0511 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314)628-2218 Fax (314) 595-6999 Email: michaelm©pottersignal.com DESIGN: Potter Model PFC - 4064 fire alarm control panel, Model CA-4064 Expander, Model lDC Expander. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. System components: PFC - 4064 Mainboard panel assembly CA - 4064 Class A expander card RA - 6500, RA - 6500R, RA - 6500F LCD remote annunciator UD -1000 DACT PSN - 1000 Power supply expander IDC - 6 Initiating device expander card LED - 16/16F LED Annunciator DRV -50 LED driver RLY - 5 Relay expander card FCB - 1000Fiber interface bridge SPG - 1000 Serial/Parallel printer card MC - 1000 Multi-connector module 3005013 EOLR 3005012 EOLR Diode Refer to listee's Installation Instruction Manual for details. RATING: Primary Operating Supply: 120/240 VAC 2.5A Secondary Operating Supply 27.3 VDC 1.0 A INSTALLATION: In accordance with listee's printed installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally 03-12-2018 dcc .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, Installation Instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7165-0328:0511 Page 2 of 2 compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 03-12-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: WCTOR WONG, Program Coordinator Fire Engineering Division (D POTTER UD2000 The Symbol of Protection Digital Alarm Communicator Features Allows for communication to Monitoring Station Communicates using SIA-DCS or Ademco Contact ID Protocols For use with IPA, AFC, and ARC series Addressable Panels and PFC-4064 Conventional Panel Status LEDs indicate operation of DACT card Installs with ease behind main panel LCD display via User Interface bracket Device address is set internally to address 1 Includes two (2) RJ45 phone cords <~> 0 @ LISTED Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The LTD-2000 communicates using the SIA- DCS or Ademco Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Technical Specifications Operating Voltage 22.0-24.OV Standby Current l6mA Alarm Current 23mA Max LTD-2000s per panel 1 Dimensions 4"W * 6"H * 1-518"D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 930/ 'S-' 30°C '860 (non-condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 lbs Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830146- REV B • 6/19 PAGE 1 OF 3 (E)POTTER The Symbol of Protection Diqital Alarm Communicator 0 RD 1X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Out to Premises Phones Tip (Brown) Ring (Grey) Out to Premises Phones Grey Tan 3-Black 4-Red 5-Green 6-Yellow 7-Blue 8- Brown Line In From Telco Tip (Green) Ring (Red) Line In From Telco ie 2 e 1 Ring Ring UD-2000 Communicator Telco Tip = Red Telco Ring = Green Phone Tip = Brown Phone Ring = Grey MTUM Install in accordance with compatible fire alarm control panel installation manual Installation The UD-2000 DACT is connected to the control panel using the provided four-wire cable connection (PIN 5210514) between P4 and LTD-2000 P1. The connection is power limited and supervised. Power system down. Slide the UD-2000 into the card guides located under the User Interface bracket. Secure the LTD-2000 to the User Interface bracket using the provided #6-32x3/8" screw Install the provided four-wire conductor jumper between UD-2000 P1 and P4. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 . www.pottersignal.com 8830146-REVB • 6/19 PAGE 2OF3 P Connector on main board I Slides in guides under rnaln bourd. P Connector on small platform control panel (D POTTER UD200 The Symbol of Protection Digital Alarm Communicator UD-2000 DACT Installation on UD-2000 DACT Installation on Small Platform Panel Large Platform Panel Fig 1 Fig2 Ordering Information Model Description Stock No. UD-2000 Digital Alarm Communicator 3992769 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 . www.pottersignal.com 8830146- REV B • 6/19 PAGE 3OF3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Q LISTIN G SERVICE LISTING No. 7300-0328:0515 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Michael Mclsaac (314) 628-2218 Fax (314) 595-6999 Email: michaelm©pottersignal.com DESIGN: Models UD-1000 and *UD 2000 Digital Alarm Communicator Transmitters (DACT). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as a digital alarm communicatior for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. *Rev 01-09-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct C) RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division PS-DA and PS-SA Conventional Pull-stations Easy to Install and Operate The PS-DNPS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock I reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and mul- tiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate. Operation The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS- DA/PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. Molded terminal numbers can be found adjacent to the wiring termi- nals. Models: PS-SA— Single action with 'pigtail' connections and a key lock reset. Pigtail wires are provided for con- nection to the Fire Alarm Control Panel's (FACP) initiation circuit. PS-DA - Dual action model with screw terminal connections and a key lock reset. PS-DAH - Same as PS-DA except with hex lock reset. PS-DALOB - Same as PS-DA with "outdoor use" listing. Includes SB- I/O backbox and sealing gasket. SILENT KNIGHT by Hrwll [F DLL ATIVA. TED 4] fi ci F] PS-DA PS-DASP - Same as PS-DA except with both English and Spanish operating instructions. Features: UL Listed CSFM Listed Meets ADA requirements Operating instructions are mold- ed into the handle along with Braille text. Made of durable Lexan Available in Spanish Key resettable Easy to Install and operate Single or dual action Surface mount box available PS-DASP Specification: Dimensions: Height: 5-1/2" (13.97 cm) Width: 4"(10.l6cm) Depth: 1-7/16" (3.65 cm) Operating temperature: 32°F to 120°F (0°C to 49°C) Electrical: Switch Contact Rating: 0.25A@ 30 VAC orVOC Accessories: SB-I/O Surface Mount Back-box BG-TR Trim Ring PS-DA and PS-SA 0 Conventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. IN IRWIN- ON ;gl (' I~KQL / - PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA ci I1 KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are sub- P/N 350241 Rev. C ject to change without notice. For more information, contact Silent Knight 12 © 2009 Honeywell International Inc. by lliywl Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0140 Page 1 of I CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: Iisa.brant@honeywell.com DESIGN: Models PS-SA, PS-DA, PS-DASP and IDP-PULL-DA fire alarm pull boxes. The PS series followed by SA or DA is a single action or dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, Installation Instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: WCTOR WONG, Program Coordinator Fire Engineering Division SIGWU1G LISTED Ll 7DD ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. 9J L'MNi] @MOMM (I Pj@#@jR§ 0 14gj Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard Wcat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information ISO 9001 Space Age Electronics, Inc. J . REGIST IMFIRA 4Y ERED 800.486.1723 Toll Free MOMM COMPANY Made In 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! ñSPACE AGE EJELECTRONICS INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. 3 USB Storage Interface Requires Standard USB-B Connector Fa.tb.vtBd.PttE1al(.1O) H o Pmgaity IIdBmatIon Mhmwn R.ulmd Do,um.ntatlon (8IGfUN) C.,llflcaUon, aid App,aal. il Syini k1*takticn Catia flldrfl. I0-i1*e*Sthth.a 6kKBJUd,th ft IItit!aI.SMW.Saaa,7L1a1172 4niIpmant knfonni.don U_sit Os, _____________ Il_sM. adn*tbsAdmSIn1c.baI.ni,,qj7 _sfr..IIBA, Ia l.a_s_s _saMAOlBA BIOINIlU 1.1 U1 0844 Rain I _- Key Ring Hooks Business - ' 2 Card Holder Al c' f 0 --' - - -;-.,._'-••___ \ Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) IN No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL C FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of I CATEGORY: 7300 FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. Lel 02-09-16 dc , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct () operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division System Sensor j3M series smoke detectors represer significant advancement in conventional detect, The P family is founded on three principles: instaL.. ti[c it t(t4t(®1 15YSTEJ JSEN5 ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings FM WA IS LISTED APPF&M approved approved 0. S911 3011446 7272-1653:152 29001-E 2093 3180932 Installation ooso.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads).The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the Installation, l heads plug Into the base with a simple Stop-Drop 'N Lock' action. IntoIHgonco. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire j3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityof i detectors In terms of percent-per-foot obscuration. Instant InspoctIon.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire I3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j Smoke Detector Specifications O '•' Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/,-inch and 4-Inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 25 percent-per-foot nominal as measured In the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2Wr-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 1 2/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V. 23 mA @24 V Peak Standby Current 2-wire: 100 pA 4-wire: rila Alarm Contact Ratings 2-wire: ri/a; 4-wire: 05 A @ 30V AC/DC Il Dimensions (including base) 53 inches 027 mm) diameter; 2.0 inches (51 mm) height Weight 6302(1789) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2W1-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (572°C) fixed Freeze Trouble 2Wl-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal InputTerminals () Mounting 14to22AWG 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every S seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2Wr-B Yes 2-wire 130 mA max limited by control panel 4W-B No 4-wire -- 20 mA @ 12 V, 23 mA @24 V 4W1-B Yes 4-wire 20mA@12V.23mA@24V Accessories 2W-MOD2 2-wire loop test! maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 0 3825 Ohio Avenue. St. Charles, IL 60174 Product Wedlications subject C2009 System 5e,5Or. to changewftut notice Visit systemsemorcomfo,. SEA 150A 0 Phone: 800-SENSOR2. Fax: 630-377-6495 current product iftlormation, inducing the latest %,erslon of Ns data street A05.038-007 . 59 .2169 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM $ LISTI NG SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.branthoneywelI.com DESIGN: Models 2W-B, 2WT-B, 4W-B, and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and models 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (1350F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 *Revision 09-21-20 VWW .ø This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not WO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, Installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division CWSTEM ®1!ti itIL® [FinquencykI®1iJiI r,iIiJ rind iD.O~w [Finq uakney I®]tUiI System Sensor L-Series audible visible notification products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics. Features . 520 Hz ± 10% square wave tone, NFPA compliance C Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications Compact, standard, and round ceiling options Field-selectable candela settings. Wall units: 15, 30, 75, 95, 110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177 Rotary switch for High/Low, Temp3, Temp4, and Continuous settings. Sounder-only models also offer a Coded setting. Plug-in design with minimal intrusion into the back box Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices (Direct replacement for HW/R-LF and P2RIWH-LF) Compatible with MDL3 sync module Sounders listed for ceiling and wall Round Sounder Strobes listed for ceiling and wall Updated modern aesthetics Agency Listings SIGIIALJG C O~ USTED S4011 PR452768 Hams only. 712&1650516 Horn/Strobes: 7125-16530517 The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any application requirement. The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24- volt operation, and a rotary switch for 520 Hz low frequency sounder tones. AVDS910-02 • 11/02/2020 • Page 1 L-Series Specifications General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuif" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit (000 to 49°C) from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings. Wall units: 15, 30, 75, 95, 110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177. The field selectable tones will sound within the frequency range of 520 Hz *10% square wave tone and have a permanent marking on the housing that reads '520 Hz". Low Frequency Sounder The low frequency sounder shall be a System Sensor L-Series Model ______ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync.CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built-in sync). When used with the Sync.Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non- temporal (continuous) pattern and coded supply within the frequency range of 520 Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411A6 x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Ii 1 Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 24 DCflWR' Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wail Sounder Strobe (Including lens) 5.6" Lx 4.T W x 1.9"D (142 mm Lx 119mm W x 49mm D) Ceiling Sounder Strobe (including lens) 6.8" diameter x 2.47" high (173mm diameter x 62.7 mm D) Standard Wall Sounder 5.6" Lx 4.7"W x 1,5'D (142 mm Lx 119 mm x 38 mm D) Compact Wall Sounder 5.25'L x 3.46" W x 1.5 D (133mm Lx 88mm W x 38mm D) Ceiling Sounder 6.8" diameter x 1.4' high (173mm diameter x 36mm high) Standard Wall Sounder with SBBRL/SBBWL Surface 5.70" Lx 4.8" W x 3.3" D Mount Back Box (145 mm Lx 120 mm W x 87 mm D) Compact Wall Sounder with SBBGRL/SBBGWL Surface 5.4" Lx 3.6" W x 3.0" D (137 mmL x 91mm W x 76mm D) Mount Back Box Low Frequency Ceiling Sounder with SBBCRLISBBCWL 6.9" diameter x 3.9" high (175mm diameter x 99mm high) Surface Mount Back Box Notes: 1. Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. AVDS910.02 • 11/0212020 • Page 2 E01 UL Current Draw and Sound Output Data Sound Wall Sounder Strobe Current Draw (mA) Output (dBA) Volume 1633 VDC I 1633 FWR 1633V Pos Tone Settina 1 l5cd 3flcd 75cd 95cd llflcd 15cd 155cd1 l5id %fled 75d Wind lifled lRed 1Rg'd 1 nr FWR 1 Temporal High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal 3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal 4 High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal 4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 1 76 Sound Ceiling Sounder Strobe Current Draw (mA) Output Volume 1633 VDC 1633 FWR 16-33 V Pos Tone Settina 15cd 30ed 75cd 95rd llflcd 15cd Ifigindl 15d 2nrd 7Sed ficed 111 12crd Inced I flf FWP 1 Temporal High 98 115 158 173 197 236 259 136 153 188 206 238 287 291 80 80 2 Temporal 3 Low 98 102 141 162 181 224 244 150 150 176 194 226 269 269 76 76 3 Temporal High 98 108 145 161 186 224 249 200 198 169 189 222 269 1 277 80 80 4 Temporal 4 Low 102 104 122 136 170 208 227 176 174 154 173 206 252 263 76 76 5 Continuous IHigh 141 158 198 216 245 293 295 190 207 249 268 302 357 357 80 80 6 Continuous I Low 120 128 179 196 225 271 273 165 1 182 1 226 1 244 278 1 330 1 330 76 76 Wall and Ceiling Sounder Volume Pos Tone Setting Current Draw ' Sound Output (dBA) Reverberant 16-33 Volts 16-33 Volts DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal 4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 *NOTE: For coded tones. temnoral codino must be nroviden by the NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. AVDS910-02 • 11/02/2020 • Paso 3 0 Wall LF Sounder Strobe Wall LF Sounder Ceiling LF Sounder Ceiling LF Sounder Strobe L-Series Dimensions I(iatii r;1li1aii) 1 Red White Low Frequency Sounder Strobes P2RL-LF P2WL-LF LF Sounder Strobe, Wall PC2RL-LF PC2WL-LF LF Sounder Strobe, Ceiling Low Frequency Sounders HRL-LF HWL-LF LF Sounder, Wall HGRL-LF HGWL-LF Compact LF Sounder, Wall HCRL-LF HCWL-LF LF Sounder, Ceiling Accessories MDL3R MDL3W Sync.Circuittd Module, UL-listed SBBRL SBBWL Surface Mount Back Box, Wall SBBCRL SBBCWL Surface Mount Back Box, Ceiling SBBGRL SBBGWL Surface Mount Back Box, Wall, Compact System Sensor® Is registered trademark and Sync•Circult' is a trademark of Harreeii international, Inc. 1(S7TEiYYiI l%_$ Sf5cD 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 for 02020 System Sensor. current mxw information, Induding the latest version of Ns data sheeL CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LDSTHG SERVICE LISTING No. 7135-1653:0516 Page 1 of I CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models HRL-LF, HWL-LF, HCRL-LF, HCWL-LF, HGRL-LF and HGWL-LF are low frequency horns. Horn models HRL-LF, HWL-LF, HGRL-LF and HGWL-LF may be mounted on the wall and are intended for indoor use only unless otherwise indicated. Horn models HCRL-LF, HCWL-LF may be mounted on the ceiling and are intended for indoor use only unless otherwise indicated. The standard horn models are the HRL-LF, HCRL-LF (red enclosure) and HWL-LF, HCWL-LF (white enclosure). The horn has an 8 position selectable tone settings. Models HGRL-LF and HGWL-LF perform the same as HRL-LF/HWL-LF and use a "compact" housing which is intended to mount to a single gang electrical box. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: The models HRL-LF, HW-LF, HCRL-LF, HRWL-LF, HGRL-LF and HGWL-LF are rated 16-33 VdcNFWR (REGULATED 24 DCIFWR). INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, audibility ratings and UL label APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 1200F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 07-01-19 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division D1E CELLULAR ALARM CommufflCATOR Ill_I I o wdw,@@~ o %L 0=0 o __ iflI iK t UJ1, tL L o I1i; 3D a IWONAmoam W am am, GAP PRADWJDA~ o r o o @moiav MOM Wu I o - -- - -- o afl (J.thiJO II!gj IJjn7 zji am!'i - 0 1iIli $1L Jk meii %.AA 1PI !U11I I1IJJ 0 o wmm ©i11J Maw -. !IT# III1Th !IlIL II i1 J) ci I 1Ijn 4i v I.1.kiBi JI @dX1 slit 1 J1m& CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0504 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3325 Cumberland Blvd, NE, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (800) 229-2326 Fax (678) 945-1651 Email: customerservice.telular@ametek.com DESIGN: Model TG-7FS and TG-7UB Digital Cellular Radio Alarm Transmission Devices for fire alarm systems. Models are suffixed with -A for AT&T networks and -V for Verizon networks. Devices facilitate the use of the cellular network for the delivery of signals for commercial alarm panels. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 12124V0C regulated (from panel) I2VAC (from plug-In adapter) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as digital cellular alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed fire alarm control panel in accordance with the installation instructions provided by the manufacturer. 02-16-22 DAL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation Instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division