Loading...
HomeMy WebLinkAbout2014-08-06; Planning Commission; ; SDP 14-03|CDP 14-04 – CP JUNIPER APARTMENTS The City of Carlsbad Planning Division A REPORT TO THE PLANNING COMMISSION Item No. Application complete date: June 16, 2014 P.C. AGENDA OF: August 6, 2014 Project Planner: Van Lynch Project Engineer: David Rick SUBJECT: SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS – Request for approval of a Site Development Plan and Coastal Development Permit to demolish an existing single- family home, shed and detached garage to allow for the development of a four-unit multiple-family residential apartment project on a 0.2 acre infill site located at 385 Juniper Avenue, within the Mello II Segment of the Local Coastal Program and Local Facilities Management Zone 1. The project site is not within the appealable area of the California Coastal Commission. The City Planner has determined that this project is exempt from the requirements of the California Environmental Quality Act (CEQA) pursuant to Section 15301, for the demolition of a single family residence and accessory structures, and Section 15303, for the construction of no more than four dwelling units in an urbanized area of the State CEQA Guidelines and will not have any adverse significant impact on the environment. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 7067 APPROVING Site Development Plan SDP 14-03 and Coastal Development Permit CDP 14-04, based upon the findings and subject to the conditions contained therein. II. PROJECT DESCRIPTION AND BACKGROUND The applicant proposes to demolish an existing single-family home, shed and detached garage to allow for the development of a four-unit multiple-family residential apartment project on a 0.2 acre infill site within the Mello II Segment of the Local Coastal Program and the Beach Area Overlay Zone (BAOZ). More specifically, the site is located at 385 Juniper Avenue on the south side of the street, west and adjacent to the railroad tracks. The development of the proposed apartment project requires the processing and approval of a Site Development Plan and Coastal Development Permit. Topographically, the site slopes from west to east with a drop in grade ranging in elevation from approximately 45 feet above mean sea level (MSL) along the western property line to 43 feet (MSL) along the eastern property line. The site is developed with an existing unoccupied single-family home, shed and detached garage. The site is devoid of any sensitive vegetation. The one large Coast Live Oak tree along the eastern property line is to remain. The proposed apartment units (Units A-D) are attached in a U-shape configuration with a private 20 ft. wide driveway located in the center of the lot providing access to the nine parking spaces in a tuck under configuration. Three of the two-story units are located above the parking spaces on the east and west side of the lot with a common deck spanning over the drive access way. The fourth unit in the back of the lot is a two story unit over a basement with living space and an at grade two car garage. Each unit is provided with two covered parking spaces. There are four separate floor plans (Plan Types A - D) consisting of one-, two-, three- and four-bedroom units each ranging in size from 819 square feet to 2 SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 2 2,762 square feet. All units are accessed from the common raised deck via a common stairway to a sidewalk connecting to the public sidewalk along Juniper Avenue. Unit C, the rear unit, has a separate at grade entry for an accessible (handicap) room on the ground level. The building will have two stories over at-grade parking and two stories over a basement (Unit C) with an overall building height of 29′-11 1/4″. Unit C has a flat roof component that serves as a private patio space and an equipment enclosure for heating, ventilating and air-conditioning units. Unit C also has use of the rear yard setback as a private yard area. It is the intent of the project owner/developer to live in Unit C. Primary building materials are two-toned colored stucco siding, asphalt composition shingles cover a 3:12 pitched roof over most of the units, metal Stainless steel railings for the common access deck, and steel awnings cover the entries to the units. Architecturally the buildings are very simple and clean looking. The project will include water sensitive landscape elements such as native plants and low water use landscaping. In December of 2013 a four unit condominium project was approved adjacent to the west of the project site. The condominium units are attached in a four-plex configuration with a private 20 ft. wide driveway located along the east side of the building and two guest parking spaces located to the rear. Table “A” below includes the General Plan designations, zoning and current land uses of the project site and surrounding properties. TABLE A Location General Plan Designation Zoning Current Land Use Site Residential High Density (RH) 15-23 du/ac with a Growth Management Control Point (GMCP) of 19 du/ac. Multiple-Family Residential (R-3) Zone with Beach Area Overlay Zone (BAOZ) Single-family home w/shed/detached garage North RH R-3 with BAOZ Multiple-family Residential South RH R-3 with BAOZ Multiple-family Residential East Transportation Corridor (TC) TC Railroad tracks West RH R-3 with BAOZ Multiple-family Residential Table “B” below includes the project site’s gross and net acreage, the number of dwelling units allowed by the General Plan’s Growth Management Control Point (GMCP) density and the proposed projects number of dwelling units and density. TABLE B Gross Acres Net Acres DUs Allowed at GMCP (19 du/ac) Density DUs Proposed and Project Density 0.2 acres 0.2 acres 3.8 units 4 units at 20 du/ac Site work includes grading quantities of 110 cubic yards of cut, 10 cubic yards of fill, and 100 cubic yards of export. The project will also be providing half street improvements which consist of providing curb, sidewalk and gutter and a cul-de-sac bulb to terminate Juniper Avenue and drainage improvements from the cul-de-sac into the drainage structure in the railroad property. SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 3 The project meets the City’s standards and as designed and conditioned, is in compliance with the General Plan and relevant zoning regulations of the Carlsbad Municipal Code (C.M.C). III. ANALYSIS The project is subject to the following regulations: A. Residential High Density (RH) General Plan Land Use designation; B. Multiple-Family Residential (R-3) Zone and Beach Area Overlay Zone (BAOZ) (C.M.C. Chapters 21.16 and 21.82); C. Mello II Segment of the Local Coastal Program; D. Inclusionary Housing Ordinance (C.M.C. Chapter 21.85); and E. Growth Management Ordinance (C.M.C. Chapter 21.90) and Zone 1 Local Facilities Management Plan. The recommendation for approval of this project was developed by analyzing the project’s consistency with the applicable regulations and policies. The project’s compliance with each of the above regulations is discussed in detail in the sections below. A. General Plan Residential High Density (RH) Land Use Designation The General Plan Land Use designation for the property is Residential-High (RH). The RH designation allows residential development at a density range of 15-23 dwelling units per acre with a Growth Management Control Point (GMCP) of 19 dwelling units per acre. The project site has a net developable acreage of 0.2 acres. The project’s proposed density of 20 du/ac is within the RH density range of 15-23 du/ac, but is above the RH GMCP of 19 du/ac used for the purpose of calculating the City’s compliance with Government Code Section 65863. At the GMCP, 3.8 dwelling units, or 4 when rounded up per C.M.C. Section 21.53.230(e), would be permitted on this 0.2 net developable acre property. Although the project exceeds the GMCP for the RH General Plan Land Use designation by the fractional unit allocation of 0.2 dwelling units, the General Plan Land Use Element allows the City to approve residential development at a density that exceeds the GMCP for the applicable density range provided the proposed residential development complies with certain findings as discussed below. To exceed the GMCP, the project must be consistent with the following required General Plan findings: 1) that the project will provide sufficient additional public facilities for the density in excess of the control point to ensure that the adequacy of the City’s public facilities plans will not be adversely impacted; 2) that there have been sufficient developments approved in the quadrant at densities below the control point so that the approval will not result in exceeding the quadrant limit; and, 3) all necessary public facilities required by the City’s Growth Management Program will be constructed, or are guaranteed to be constructed, concurrently with the need for them created by this development and in compliance with the adopted City standards. The proposed project is consistent with the above required findings in that there have been sufficient developments in the northwest quadrant that have developed at densities below the GMCP such that the allocation of 0.2 dwelling units would not result in exceeding the quadrant limit, the project is conditioned to pay the appropriate fees to comply with City’s Growth Management Program, and the City’s public facilities plans will not be adversely impacted as the allocation of 0.2 units has already been analyzed and anticipated within the northwest quadrant. SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 4 Furthermore, pursuant to City Council Policy No. 43 – Proposition E “Excess Dwelling” Unit Bank, in approving a request for an allocation of excess dwelling units, the following three findings must also be made: 1) That the project location and density are compatible with existing adjacent residential neighborhoods and/or nearby existing or planned uses; 2) That the project location and density are in accordance with the applicable provisions of the General Plan and any other applicable planning document; and 3) That the project complies with the findings stated in the General Plan Land Use Element for projects that exceed the GMCP for the applicable density range. The proposed project is consistent with the above required findings for the allocation of excess dwelling units in that: 1) the project is located within a Residential High (RH) General Plan Land Use designation and Multiple-Family Residential (R-3) zone, which consists predominantly of attached multiple-family residential condominiums and apartment buildings that are approved at a similar density (15-23 du/ac) as the density of the proposed project (20 du/ac), 2) that the project’s location and density described above are in accordance with the applicable provisions of the General Plan for the RH Land Use designation, and 3) that the project complies with the findings stated in the General Plan Land Use Element for projects that exceed the growth management control point (19 du/ac) for the RH Land Use designation as discussed above. Lastly, the project complies with the Elements of the General Plan as outlined in Table “C” below: TABLE C – GENERAL PLAN COMPLIANCE ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Land Use Site is designated for Residential High density, (RH; 15-23 du/ac) with a GMCP of 19 du/ac. 3.8 dwelling units (4 when rounded up) could be constructed on the site at the GMCP (0.2 acres x 19 du/ac). The residential project density at 20 dwelling units per acre (4 DUs) is slightly above the RH GMCP of 19 du/ac used for the purpose of calculating the City’s compliance with Government Code Section 65863 but is within the RH density range of 15-23 du/ac. Therefore, 0.2 dwelling units will be withdrawn from the City’s excess dwelling unit bank consistent with City Council Policy No. 43. Yes Housing Provisions for affordable housing. The project is conditioned to pay an in lieu fee on a per unit basis. Yes Public Safety Reduce fire hazards to an acceptable level. The project site is located within a five minute response time of Fire Station No. 1 and has been designed to comply with the fire code, including provisions for an automatic sprinkler system within each dwelling unit. Yes SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 5 TABLE C – GENERAL PLAN COMPLIANCE (CONTINUED) ELEMENT USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM PROPOSED USES & IMPROVEMENTS COMPLIANCE Open Space & Conservation Minimize the environmental impacts to sensitive resources within the City. Utilize Best Management Practices for control of storm water and to protect water quality. The project will not create any environmental impacts to the previously graded and developed site. The project is conditioned to conform to all NPDES requirements and has been designed to include Low Impact Design (LID) elements. Yes Noise Comply with the residential interior noise standard of 45 dB(A) CNEL. Commuter rail to freight trains produces vibration in the range of 75~80 VdB at 50 feet. Federal Transit Administration identifies that 75 VdB is an impact threshold to residences. A Noise Study (February 10, 2014) was prepared by Ldn Consulting, Inc, to address any potential noise impacts occurring as a result of the project sites close proximity to the railroad tracks located adjacent to the east. To achieve the 45 dB(a) CNEL interior noise standard, the noise study includes construction design standards (window closed conditioning and window design) to be incorporated at the building construction phase. The project has been conditioned to incorporate these design standards into the building design prior to the issuance of building permits. The apartment project does not require private outdoor recreation areas and therefore no outdoor attenuation in the form of a noise wall is required. The project is located 100 feet from the actual rail lines and the VdB is estimated to be at or less than 75VdB. Yes Circulation Construct roadway improvements needed to serve proposed development. All public facilities including curb, gutter and sidewalk are conditioned to be built along the property frontage (Juniper Avenue). Yes B. Multiple-Family Residential (R-3) Zone, Planned Development Regulations, and Beach Area Overlay Zone (BAOZ) The proposed project is required to comply with all applicable use and development standards of the Carlsbad Municipal Code (CMC) including the Multiple-Family Residential (R-3) Zone (C.M.C. Chapter 21.16) and the Beach Area Overlay Zone (BAOZ) (C.M.C. Chapter 21.82). The four-unit multiple-family residential apartment project meets or exceeds the requirements of the R- 3 Zone and the BAOZ as outlined in Table “D” below. SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 6 Table D – R-3 AND BAOZ COMPLIANCE R-3 Standards Required Proposed Comply Setbacks Front yard: 20’ Interior side yard: 8’2”' Rear: 16' 4” Front yard: 20’ Interior side yards: 8' 2” Rear: 16’4”' Yes Lot Coverage Maximum of 60% 46.3% Yes Parking 1.5 spaces/unit (Studio/One Bedroom) and 2 spaces/unit two or more bedrooms, one covered = 7.5 .3 spaces/unit guest = 1.2 Total spaces = 8.7 ~ 9 spaces Nine parking spaces, all covered. Project also provides one space as an accessible parking space with requisite loading area. Yes BAOZ Standards Required Proposed Comply Building Height 30 feet with minimum 3:12 roof pitch is provided or 24 feet if less than a 3:12 roof pitch is provided Roof Peak = 29′-11 1/4″ w/ 3:12 roof pitch Roof Decks = <24 ft. Yes C. Local Coastal Program The proposed site is located outside the appeals area of the City’s Coastal Zone and lies within the Mello II Segment of the Local Coastal Program. The project site has an LCP Land Use designation of RH and Zoning of R-3, which are consistent with the City’s General Plan and Zoning. The projects consistency with the RH General Plan Land Use designation is analyzed in Section ”A,” Table “C” above. The proposed project is consistent with the Mello II Segment of the Local Coastal Program which contains land use policies for development and conservation of coastal land and water areas within its boundaries. The policies of the Mello II Segment emphasize topics such as preservation of agriculture and scenic resources, protection of environmentally sensitive resources, provision of shoreline access and prevention of geologic instability and erosion. The project is consistent with the coastal act policies as follows: a) no agricultural lands exist on the project site, therefore no impacts to such will occur; b) the site does not contain or impact environmentally sensitive habitats, water or marine resources; c) the site is geologically stable and the proposed grading for the site has been limited to the area necessary to develop the site; d) the project has been designed to reduce the amount of off-site runoff and has been conditioned to implement the NPDES standards to ensure the quality of the water leaving the site; e) the project meets the parking requirements for apartments; f) the project does not preclude any recreational opportunities or shoreline access as the property is located on the south side of Juniper Avenue between Garfield Street and the railroad tracks; and, g) the development of four residential apartments will not obstruct views of the coastline as seen from public lands or public right-of-way. Given the above, the project is consistent with the Mello II segment land use policies. SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 7 D. Inclusionary Housing Ordinance Typically a market rate rental project is not subject to the inclusionary housing requirements. Because the project is receiving .2 dwelling units from the Excess dwelling Unit Bank, this has been determined to be an “incentive” by City Council Policy Number 43 and is therefore subject to the inclusionary housing ordinance. An allocation of excess Dwelling Units to a project is an “incentive,” as defined in CMC (Carlsbad Municipal Code) Section 21.86.020(A)(12) and Government Code Section 65915(k), in that regulatory concessions that modify the requirements of CMC Chapter 21.90 by permitting developments with more dwelling units than otherwise permitted by the growth management control point (GMCP) established in CMC 21.90.045. The allocation of excess Dwelling Units to a project will result in identifiable, financially sufficient, and actual cost reductions to the project by permitting more Dwelling Units on a site than would otherwise be allowed by the underlying General Plan land use designation and so reducing land cost per dwelling unit. The project developed with three units would have a density of 15 dwelling units per acre and would be at the low end of the General Plan land use allowance (15 to 23 du/ac) for the site and would not require an allocation of units from the Excess Dwelling Unit bank, but would then be depositing .8 dwelling units as the project would be below the GMCP of 19 dwelling units per acre. The inclusionary housing requirement will be satisfied through the payment of an inclusionary housing in-lieu fee on a per unit basis as required by CMC Chapter 21.85 in consideration for the allocation of excess Dwelling Units. E. Growth Management The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the City. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table “E” below. TABLE E – GROWTH MANAGEMENT COMPLIANCE STANDARD IMPACTS COMPLIANCE City Administration 13.91 sq. ft. Yes Library 7.42 sq. ft. Yes Waste Water Treatment 4 EDU Yes Parks 0.028 acre Yes Drainage 0.9 CFS Yes Circulation 24 ADT Yes Fire Station No. 1 Yes Open Space 0 acres N/A Schools Carlsbad (E=.6832/M=.2264/HS = .2932) Yes Sewer Collection System 4 EDU Yes Water 1,000 GPD Yes The project proposes 4 dwelling units whereas the maximum unit yield at the GMCP of the property is 3.8 (4 units when rounded up) dwelling units. The proposed 4-unit project is 0.2 units above the Growth Management Control Point density for this RH designated property. Consistent with the General Plan and Policy No. 43, 0.2 dwelling units will be withdrawn from the City’s excess dwelling unit bank. SDP 14-03/CDP 14-04 – CP JUNIPER APARTMENTS October 6, 2014 Page 8 IV. ENVIRONMENTAL REVIEW The City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment, and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15301 for the demolition of a single family residence and accessory structures and Section 15303 for the construction of no more than four dwelling units in an urbanized area Categorical Exemptions of the State CEQA Guidelines. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. A Notice of Exemption will be filed by the City Planner upon final project approval. ATTACHMENTS: 1. Planning Commission Resolution No. 7067 2. Location Map 3. Disclosure Statement 4. Reduced Exhibits 5. Full Size Exhibits “A – S” dated August 6, 2014 H I B I S C U S C R T A M A R A C K A V G A R F I E L D S T REDW O O D A V ACAC I A A V HEML O C K A V JUNI P E R A V V I L L AGE C R A N C H O R W Y N A U T I C A L D R V I L L A G E D R SDP 14-03 / CDP 14-04 CP Juniper Apartments SITE MAP EL CAM REAL C A R L S B AD VILL AGE DR C A R L S B A D B L L A COSTA AV PALOM AR AIRP ORT R D MELR O S E DR A V IARA PY RANCHO S ANTA FE RD C OLL E GE BL EL CAMINO REAL SITE Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Ex p o r t D a t e : SDP 14-03 / CDP 14-04 7/ 1 9 / 2 0 1 4 1 2 : 1 6 : 0 1 P M A-001 Cover Sheet, Index 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1 Axonometric - from NE 2 Axonometric - from NW 3 Axonometric - from SE 4 Axonometric - from SW ARCHITECTURE / GRADING / LANDSCAPE A-001 Cover Sheet, Index A-002 General Notes, Code Requirements A-003 Site - Existing Conditions A-004 Site - Architectural / Grading Plan A-005 Site Sections / Elevations A-006 Site - Landscape Plan A-101 Ground Level Plan A-102 Deck Level Plan A-103 Upper Level Plan A-104 Upper Roof Plan A-201 Perimeter Elevations A-202 Perimeter Elevations A-203 Courtyard Section/Elevations A-204 Courtyard Section/Elevations A-301 Building Sections A-302 Building Sections A-303 Building Sections A-304 Building Sections A-601 Window/Door Schdl, Glazing Details OWNER/APPLICANT CP Juniper, LLC Tyler Van Stright, Manager 235 Pine Ave Apt Q Carlsbad, CA 92008 tyler@jlcarchitecture.com (760) 521-0866 No. Description Date 2,163 sf Carport (S-2) 436 sf Private Garage (U) 2,287 sf Dwelling Unit C (R-2) 1 HR separation at wall btwn (S-2) and (R-2) 1/2 HR separation at wall btwn (U) and (R-2) per 406.3.4 extent of coverage ovhd 2,287 sf Dwelling Unit C (R-2) 2,930 sf Dwelling Unit C (R-2) 1 HR separation at wall btwn dwelling units, min 50 STC 1/2 HR separation at floor btwn (U) and (R-2) per 406.3.4 1 HR separation at floor btwn dwelling units 2,930 sf Habitable Deck (R-2) 1 HR separation at floor btwn (S-2) and R-2) 90' exit route (longest condition) 2,287 sf Dwelling Unit C (R-2) 2,930 sf Dwelling Unit C (R-2) 1 HR separation at wall btwn dwelling units, min 50 STC 1 HR separation at floor btwn dwelling units, min 50 STC 1 HR separation at floor btwn (S-2) and R-2) 90' exit route (longest condition) Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Ex p o r t D a t e : SDP 14-03 / CDP 14-04 7/ 1 9 / 2 0 1 4 1 2 : 1 6 : 0 3 P M A-002 General Notes, Code Requirements 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 GENERAL NOTES 1.Receptacle outlet locations will comply with CEC Article 210.52 (A) 2.Bathroom circuiting shall be either: a.) 20 amp circuit dedicated to each bathroom, or b.) At least one 20 amp circuit supplying only bathroom receptacle outlets 3.Bedroom branch circuits will be arc fault circuit protected per CEC Article 210.12 (B) 4.GCFI protected outlets for locations described in NEC 210.8: kitchens, garages, bathrooms, crawl spaces, laundries, wet bar sinks, outdoors, within 6” of sink, etc.5.Per CEC Article 510.52 (C): in kitchens a receptacle outlet shall be installed at each counter space 12" or wider; receptacles shall be installed so that no point along the wall line is more than 24"; peninsular countertops 12" by 24" long (or greater) shall have at least one receptacle. (Counter spaces separated by range tops, refrigerators or sinks shall be considered as separate counter top spaces.) 6.Tamper resistant receptacles for all locations as described in CEC Article 210.52 (i.e. all receptacles). 7.Weather resistant type for receptacles installed in damp or wet locations (outside). 8.Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12 (B): family, living, bedrooms, dining, halls, etc. 9.Bathroom circuiting shall be either a.) A 20 amp circuit dedicated to each bathroom, or b.) At least one 20 amp circuit supplying only bathroom receptacle outlets. ELECTRICAL 1.Water conservation measure must meet a 20% reduction rate according to the table 4.303.2 (see table to right) per CGC, effective 7.01.2011. 2.When a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed the 20% reducedlimit, or the shower shall be designed so that only one head is on at a time. CGC 4.303.2. 3.The control valves in bathtubs and shower combinations must be pressure balanced or have thermostatic mixing valves per CPC Section 414.5 and 418.0 4.All hot water piping from the heat source to the kitchen fixtures must be insulated (2" or less pipe = 1" thick insulation; greater than 2" pipe size = 1.5" insulation). 5.State health and safety code Sec. 17921.1 bans the use of chlorinated polyvinyl chloride (CPVC) for interior water supply piping. 6.Permanent vacuum breakers shall be included with all new hose bibbs. 7.All ABS and PVC piping and fittings shall be enclosed within walls and floors covered with "type X gypsum board" or similar assemblies that provide the same level of fire protection. Protection of membrane penetrations is not required. PLUMBING Stairs -width shall be a min of 36" clear, handrails shall not project more than 4.5" on either side of the stairway -minimum headroom on all parts of the stairway shall be 6'-8" measured vertically from a sloped line adjoining tread nosing -max riser height = 7.75", minimum tread depth = 10" -required landings shall have a minimum dimension of 36" measured in the direction of travel Handrails -handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers - handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finished surface of ramp slope, shall be min 34", max 38" -handrails for stairways shall be continuous for the full length of the flight, from a point directly above thetop riser of the flight to a point directly above the lowest riser of the flight -handrails shall provide code compliance with grip-size requirements (R311.7.7.3) -handgrips adjacent to wall shall have a min of 1.5" between wall and handrail, extensions shall be returned or shall have round terminations or bends Guards -shall have a height of 42", may be 34" along sides of stairs -opening between guardrails shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6" -shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail per R301.5. See structural for detailing/calculations. STAIRS/HANDRAILS/GUARDRAILS 1.Site shall be planned and developed to keep surface water away from buildings. Plans shall be provided and approved by the City Engineer that show site grading and provide for storm water retention and drainage during construction. BMP’s that are currently enforced by the city engineer must be implemented prior to initial inspection by the building department. CGC 4.106.3. 2.A min of 50% of construction waste is to be recycled. CGC 4.408.1. 3.The builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. 4.During construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. 5.VOC’s must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. 6.Bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. 7.If provided, whole house exhaust fans shall have insulated covers or louvers which close when the fan is off. The covers or louvers shall have minimum R4.2 insulation. CGC 5.507.1. 8.Heating and AC shall be sized and selected by ACCA Manual J or ASHRAE handbook or equivalent. The duct sizing shall be sized in accordance with one of the ACCA methods listed in CGC Section 4.507.2. 9.Prior to final approval of the building the licensed contractor, architect or engineer in responsible charge of the overall construction must complete and sign the Green Building Standards Certification form and given to the building department official to be filed with the approved plans. 10.Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with US. EPA Phase II emission limits where applicable. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. CGC 4.503.1 11.Mechanical exhaust fans which exhaust directly from bathrooms shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidistat which shall be readily accessible. Humidistat controls shall be capable of adjustment between a relative humidity range of 50 to 80 percent." CGC 4.506.1 GREEN BUILDING STANDARDS 1.Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 2.Paints, stains and other coatings shall be compliant with VOC limits. 3.Aerosol paints and coatings shall be compliant with product weighted MIR limits for VOC and other toxic compounds. 4.Documentation shall be provided to verify that compliant VOC limit finish materials have been used. A letter from the contractor and/or the building owner certifying what material has been used and its compliance with the code must be submitted to the building inspector.5.Carpet and carpet systems shall be compliant with VOC limits. A letter from the contractor and/or the building owner certifying what material has been used and its compliance with the code must be submitted to the building inspector. 6.50% of the floor area receiving resilient flooring shall comply with VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low-Emitting Materials List or be certified under the Resilient Floor Covering Institute (RFCI) Floor Score Program. 7.Particleboard, medium density fiberboard (MDF), and hardboard plywood used in interior finish systems shall comply iwth low-formaldehyde emissions standards. A letter from the contractor and/or the building owner certifying what material has been used and its compliance with the code must be submitted to the building inspector. 8.Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when framing members exceed 19% moisture content. 9.The moisture content of building materials used in wall and floor framing is checked before enclosure. Moisture content shall be verified by either a probe type or contact tpe moisture meter. A certificate of compliance indicating date of test, location and results issued by the framing subcontractor or general contractor must be submitted to the building inspector. CAL GREEN - GENERAL MATERIAL NOTES Method used for the selection of Heating and Air Conditioning equipment: Energy Pro software per ASHRAE based heating and cooling calculations. HVAC FIRE NOTES 1.New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast in color to background. Numbers shall be a minimum of 4” high with a minimum stroke width of ½ inch (per CFC Section 505.1). 2.AUTOMATIC FIRE SPRINKLER SYSTEM - An Automatic Fire Sprinkler System shall be installed as perN.F.P.A. 13D, the most current edition shall be used and the Encinitas Fire Department policies. Detailed sprinkler plans shall be submitted to the Fire Prevention Bureau and approved prior to installation. Plans and installation must be by a C16 licensed sprinkler contractor. New garage will require fire sprinklers and new cabana will require fire sprinklers. Existing fire sprinkler heads in existing residence may need to be relocated or additional fire sprinkle heads may need to be added for proper coverage. 3.A Hydro inspection of the fire sprinkler system is required prior to frame inspection. Only the new piping shall be tested. DEFERRED SUBMITTALS •Truss Calculations. If trusses are part of the structural design the General Contractor to provide design-build for all trusses unless otherwise noted. •Automatic Fire Sprinkler System. If fire sprinklers are required, General contractor to provide full design-build services including but not limited to survey of existing conditions, design, constructiondocuments, permit, construction and testing. Sprinkler plans must be submitted for review prior to any general building inspections. Fire Sprinkler Notes: The submittal of residential fire sprinkler plans required by California Residential Code Section R313 has been deferred. To avoid delays in construction, plans for fire sprinkler plans shall be submitted not less than 30 calender days prior to installation or prior to requesting a foundation inspection when the submittal of fire sprinkler plan is deferred. A framing/rough inspection shall not be requested prior to approval of the fire sprinkler plans. Residential systems designed to the requirements of NFPA 13D or NFPA 13R shall include the following: a. Garage areas will be included in the area to be sprinklered. Protection of the heads will be required for all heads installed in garage areas. b. All bathrooms, regardless of square footage, shall be protected. c. A backflow protection device shall be required. d. A fire alarm signal shall be provided by a water flow switch located on the sprinkler riser and the alarm bell shall be of sufficient intensity to be clearly audible in all bedrooms. e. Domestic water supply shut off shall be installed so that the residential sprinkler system cannot be shut off, except at the meter. f. Residential dwellings constructed more than 150 feet from a roadway meeting public road standards shall be provided with a sprinkler system. 1.All notes listed below are applicable unless otherwise noted within the construction documents or specifications. 2.All work to be done in accordance with local codes, laws, ordinances, CAL-OSHA, city, county, state, and national standards and safety codes including but not limited to 2013 edition of the California Code of Regulations (Title24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC, 2011 NEC 3.All Residential projects shall comply with the 2013 California Residential Code which adopts the following model codes: 2012 IRC, 2012 UPC, 2012 UMC, 2011 NEC 4.Changes to the approved drawings and specifications shall be made only by owner approved addenda or change order. 5.The contractor shall verify in the field all dimensions, elevations, flow lines and points of connection with adjacent properties; any discrepancies shall be called to the architect's attention before proceeding with the work. 6.The contractor shall determine the location of utility services in the area prior to excavation. The contractor shall assume responsibility for the protection of existing utilities and pavement within the area of the work whether indicated on the drawings or not, unless otherwise noted. All utilities to be underground per utility company and local code requirements. 7.Should any condition arise where the intent of the drawings is in doubt where there is a discrepancy or appears to be an error on the drawings between the drawings and the field conditions, the architect shall be notified as soon as reasonably possible for procedure to be followed. 8.Where details are not shown for any part of the work, the construction shall be similar to other similar work, or contact the architect for clarification. 9.Workmanship throughout shall be of the best quality of the trade involved. 10.Each subcontractor is considered a specialist in his respective field and shall, prior to the submission of bid or performance of work, notify the general contractor or owner of any work called out on the drawings in his trade that cannot be fully guaranteed. The contractor and/or subcontractors shall be responsible for the appropriate "hook-up" to all utilities required to support the work. 11.Permits, fees, taxes, licenses, and deposits shall be paid for and obtained by each sub-contractor and the general contractor as they relate to their work. 12.These drawings do not include necessary components for construction safety of all parties present on the job site. This is the contractor's responsibility. 13.The contractor shall protect adjacent properties and site work at all times. 14.All dimensions are to face of studs, masonry or centerline unless noted otherwise. Do not scale drawings. Dimensions prevail. 15.Do not make connection, brace, or suspend any construction or equipment from the roof deck or joists unless indicated on the drawings. 16.Any periodic visits to the job site by the architect are for provisions of the contract documents, and are in no way a guarantee or insurance that the finished project totally complies with the contract documents. 17.The architect does not assume any of the responsibility for methods or appliances used by the contractor, nor safety of the job in compliance with the laws and regulations. 18.All construction and demolition debris shall be removed from around the buildings, the driveways, sidewalks and landscaping at the end of each work day. The driveways and sidewalks shall be swept clean. 19.The contractor shall limit the site storage of material, supplies or temporary structures to those areas as indicated on the drawings or as approved by the owner's representative. 20.The contractor shall repair or replace any items damaged during demolition or construction indicated to be reused or to remain, at no cost to the owners. 21.Building insulation shall be certified by the manufacturer to meet the California quality standards for insulating materials. 22.All new glazing will be installed w/ certifying label attached showing the "U" value. 23.The contractor shall provide a separation or barrier between all dissimilar metals. 24.All exterior metal, including but not limited to weld plates, flashing etc., shall be primed and painted per the specification (copper shall be left unpainted, unless otherwise noted). 25.Interior finishes shall conform to the requirements of Chapter 8, Uniform Building Code. Maximum 1 "Sone" rating for continuously running fans Maximum 3 "Sone" rating for fans w/ intermittent use VENTILATION 1.Provide permanently wired smoke detectors (SD) with battery backup power in each sleepingroom and in a central location to protect sleeping areas. Also provide permanently wired in smoke detector with battery backup on each story and in basement. 2.Where more than one smoke alarm is required to to be installed within a unit, the smoke alarms shall be interconnected in such a manner that the activiation of one alarm will activate all of the alarms in the unit. 3.Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could privide access for hard wiring and interconnected without the removal of interior finishes. SMOKE DETECTORS 1.In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages) provide permanently wired carbon monoxide detectors with battery backup power outside each sleeping area in the immediate vicinity of the bedrooms. Also provide permanently wired in carbon monoxide detector with battery backup on each story and in basement. 2.Where more than one cabon monoxide alarm is required to to be installed within a unit, the alarms shall be interconnected in such a manner that the activiation of one alarm will activate all of the alarms in the unit.3.Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could privide access for hard wiring and interconnected without the removal of interior finishes. CARBON MONOXIDE DETECTORSCM SD 1.Insulation at all roof locations to be minimum R-value per EN-101 2.Roof covering must be Class A minimum. No wood shakes or shingles allowed. 3.Attic ventilation openings shall be covered with corrosion resistant metal mesh with 1/8" min to 1/4" max openings. 4.New low-slope Roof - Mnf: John Mansvill, Product: APP Modified Bitumen Heat Fused Systems (see specification below). Class A rated. 5.New slope Roof - Mnf: Owens Corning, Product: Supreme Shingles (Class A rated) 6.Deck Coating - Mnf: Westcoat, Product: ALX, see cut sheet ROOF NOTES (Class A Roof Required) Manufacturer: Johns Manville Product: APP Modified Bitumen Heat Fused Systems Deck: C-15/32 Base Sheet: Two Plies Type G2, "Permaply 28", "Glasbase" or "Dibiglass Base", Mechanically Fastened Or Hot Mopped. Membrane: "Appex 4.5m Fr", "Dibiten Poly 4.5 Fr", (Modified Bitumen), Heat Welded. UL Listing: R10167 1.All lighting must comply with all mandatory measures per EN-101. 2.In kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non- high efficacy fixtures switched separately. 3.In bathrooms, garages, laundry rooms, and utility rooms all fixtures must be high efficacy style or controlled by a vacancy sensor. 4.All other rooms require any installed fixtures to be high efficacy or be controlled by a vacancy sensor or dimmer. (Closets under 70 SF are exempt.) 5.Outdoor lighting fixtures that are attached to the building are required to be high efficacy or be controlled by a combination photo-control/motion sensor. LIGHTING EFFICIENCY 3/32" = 1'-0" 1 Code - 1 - Ground/Lower Level 3/32" = 1'-0" 2 Code - 2 - Deck/Split Level 3/32" = 1'-0" 3 Code - 3 - Upper Level No. Description Date 43'-0" 44 ' -0" 4 5'-0 " 46'-0" 4 3'-0" 44'-0" 45'-0" 43 ' -0" 43'-0" 4 4 ' - 0 " 43'-0" 43'-0" 43'-0" 43'- 0 " 43'-0" 4 3'- 0" (e) house to be demolished (e) shed to be demolished (e) garage and carport to be demolished wood fence to be removed railroad sign guard rail pending retaining wall and fence (e) trees to be removed pending sidewalk dirt driveway wood fence to be removed wood fence to be removed extent of asphalt 30 ' - 0 " (e) 6" water water valve tele pedistal bollard sewer manhole 12 ' + / - 10 ' + / - 7' + / - (e) 6" sewer (e) 1" H.P. gas fire hydrant (30' +/-) (e ) 1 0 " s e w e r (e ) 8 " w a t e r (e) water meter (e) electrical mater and panel (e) gas meter (e ) s e w e r l a t e r a l t o be a b a n d o n e d (e ) g a s l a t e r a l t o be a b a n d o n e d Note: improvements at 369 Juniper shown as pending pending driveway (e) olive tree to remain 34 ° 3 3 ' 0 7 " 11 5 . 0 0 ' S E 55° 26' 53" 76.50' S W extent of railroadright of way N 3 4 ° 3 3 ' 0 7 " W 11 5 . 0 0 ' N 55° 26' 53" E 76.50' Juniper Avenue (CL) (e) oak tree to remain (21" diameter as shown), trim canopy as required 12" dia Chinese Elm 18" dia Chinese Elm 15" dia Chinese Elm 19" dia Chinese Elm 22" dia Chinese Elm N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Ex p o r t D a t e : pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/ 1 9 / 2 0 1 4 1 2 : 1 6 : 0 4 P M A-003 Site - Existing Conditions 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/8" = 1'-0" 1 Site - Existing Conditions No. Description Date UP DN UP UP UP 43'-0" 43'-0" 43'-0" 4 3'-0 " 44'-0" 45'-0" 46'-0" 4 4 '-0 " 4 3 ' - 0 " 44'-0" 44'-0" 52'-0" van accessible standard standard side setback 81'-7 1/2" x 0.10 = 8'-2"1" clr 59'-0" 1'-0"1" clr side setback 81'-7 1/2" x 0.10 = 8'-2" (n) sidewalk standard (covered) standard (covered) 2 0 ' fr o n t s e t b a c k 20'-0" clr 20 ' - 0 " c l r standard (covered) (n) 5' tall masonrytrash/recycling/yard waste enclosure (2 containers per type) 403 SF C-Garage1 f i r e : 150' hos e pu l l 39'-11" (FF) 44'-4 1/2" re a r s e t b a c k 81 ' - 7 1 / 2 " x 0 . 2 0 = 1 6 ' - 4 " 8 7 6 1 2 3 45 (e) 6' masonry wall to remain (n) masonry wall and fence along east PL, see elevation (arc length at front setback) 8 1 '-7 1/2 " standard (covered) standard (covered) 3' - 4 " 3' - 6 " 44'-0" (FF) 46'-3" 46'-3" 44'-0" mi n 1 % min 1% 20'-0"24'-0" (24' min drive aisle) 8' - 6 " 8' - 6 " 20'-0" 8' - 0 " 9' - 0 " 8' - 6 " 8' - 6 1 / 2 " 8 ' - 6 3 / 4 " 8 ' - 6 1 / 2 " 20'-0" 18'-0" 4.7% 20'-0 " w i d e driv e w ay 44'-0" 42'-11" 43'-10" 43'-10" 43'-11" (e) wall steps to 11' tall (e) 6' wood fence to remain 13 ' - 4 " 3'- 1 " 2 A-005 2 A-005 45'-9" 45'-3" 44'-9"top of deck = max 30" above grade (no railing required) 2% 76'-6" 43'-5" min 1% TC 43'-8" TC 44'-2" TC 44'-1" TC 44'-7" TC 45'-0" 45'-0 1/2" 47'-0" 4 2'-0" 43'-9" 43'-7" 43'-0" 43'-1" 43'-1" 43'-1" 44'-7" TC 43'-6"DRAINAGE (n ) sid e w alk future sidewalk (not a part) (e) crown cul de sac dimensions per city standard GS-3 pending sidewalk extent of asphalt DRAINAGE DRAINAGE DRAINAGE Juniper Avenue (CL) (e) railroad sign (e) guard rail Note: improvements at 369 Juniper shown as pending pending retaining wall and fence on adjacent property pending driveway (e) oak tree to remain (21" diameter as shown), trim canopy as required 30 ' - 0 " (e) 6" water (e) water valve (e) tele pedistal (e) bollard (e) sewer manhole FL. EL 36.00' per improvement plan project No. 8-19, drawing No. 117-2 12 ' + / - 10 ' + / - 7' + / - (e) 6" VC sewer (slope = 2.63% per improvement plan project No. 8-19, drawing No. 117-2) (e) 1" H.P. gas (e) fire hydrant (30' +/-) (e ) 1 0 " V C s e w e r m a i n (s l o p e = 0 . 2 8 % ) (e ) 8 " w a t e r (e) 5/8" water meter, upgrade as required (n ) g a s l a t e r a l 43'-0" 43'-3" 2.2% 43'-2" 44'-3"44'-3" 34° 33' 07" 99.84' N W 55° 26' 53" 76.50' S W 73° 11' 46"14.33' N E 55° 26' 53" 4.53' N E R = L =6 1.5 1'5 2.0 0' accessible P.O.T. accessible P.O.T. accessible living space and bath at Unit C 30'-0" (60' ROW) line of deck ovhd line of bldg ovhd downspout (typ) downspout (typ) railroad right of way vehicular site lines, see landscape plan line of deck ovhd 1" clr from setback at face of finish (typ at all bldg walls) extent of (e) asphalt street pavement and base, sidewalk and driveway apron per citystandard rear setback 81'-7 1/2" x 0.20 = 16'-4" 1" clr 22'-9 1/4" 6'-9 1/2" 26'-11 3/4" 26'-10 3/4" (n) sewer lateral (see site section) standard9 (5' min) 5'-0 1/2" A-0053 1 A-005 1 A-005 fence detail flow direction wide hatch = proposed public street dedication ROW (e) electrical service connection from (e) transformer (part of scope of work for project at 369 Juniper) pad@39'-3" pad@43'-3" pad@43'-4" I.E. approx 33.0' see site section raised planter 44'-8"43'-8"43'-0" surface flow at adjacent property raised planter (e) 4 4.0 (e) 43. 0 (e) 43.0 (e) 45.0 (e) 43.0 mailbox (e) 44.0 44'-9 1/2" 43'-11" (FF) pad@43'-4" 44'-0" (FF) 2 % 3 % 2.5% 0.7% 1% 1% 1% 2 % 2.1% 44'-2" 0.6% TC 44'-0" (e) 43.0 HP 44'-7 1/2" HP 44'-3" 0.8% 8 . 0 % 8 . 5 % 1.8% 2.1% 1.5 % 1.5% min 1%min 2% 2% 2% 12" min gap btwn (n) and (e) masonry walls to allow drainage off property, infill w wood fence, allow drainage at base 2.5% drainage off property at woodfence, provide sufficient gap along entire base 2% 43'-10" 2% min 2% 43'-0" removed AC berm and barricade per MS 13-05 saw cut line tight hatch = (n) street pavement and base, 1.5" cold mill and AC overlay north of saw cut min 1% min 2% 43'-5"43'-4" 43'-7" 8% sloped curb at face of garage accessible P.O.T. swale line 0.6% swale at bottom of slope, direct surface flow to landscape area fl o w flow 34° 33' 07" 115.00' S E 6' tall wood fence and gate (must meet POT requirements) 1" clr7'-2 1/4" 10'-7 3/4" 3'-0 3/4" 1'-10 1/2" 36'-6 1/4" 1'-8" 13'-2" 6' tall wood fence and gate 0.8% 2'-0" overhang into landscape area 2'-0 3/4" overhang into landscape area 1% 43'-8 1/2" 43'-5" 43'-8" 1.6% extend sidewalk to pending improvements 44'-3" extent of (e) asphalt N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:11 PM A-004 Site - Architectural / Grading Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 NOTE: All building dimensions shown on this plan are measured to the exterior wall surface. 1/8" = 1'-0" 1 Site - Architectural / Grading Plan PROJECT DATA Project Name CP Juniper Permit Applications Coastal Development Permit Site Development Permit Street Address 385 Juniper Avenue, Carlsbad, CA 92008 Assessor's Parcel No. 204-240-35-00 Legal Description The Northeasterly half of the Northwesterly half of Lot 4 in block 'R' of Palisades No. 2, according to the map thereof No. 1803 filed in the office of the county recorder of said San Diego County, August 25, 1924. Site/Building Summary Existing Lot 8,798 SF (.20 acres) Required Dedication 1,228 SF Post-Dedication Lot 7,570 SF Lot Coverage 3,776 SF / 7,570 SF = 49.9% Building Size 5,652 SF (see table) Landscape % 2,488 SF / 7,570 SF = 32.9% Zoning Summary Zoning Designation R-3 General Plan Designation RH Overlay Zones Beach Area, Coastal Zone Existing Land Use Residential - Single Family Proposed Land Use Residential - Apartments Density Summary Land Use Density Range 15-23 du/acre GMCP Density 19 GMCP Density Calculation 0.20 acres x 19 du/acre = 3.8 units Proposed Density Calculation 0.20 acres x 20 du/acre = 4.0 units Proposed Number of Units 4 Project proposes the withdrawal of 0.2 units from the "excess dwelling unit bank" in accordance with the requirement of City Council Policy No. 43. Parking Summary 2.0 spots per 2 bedroom unit 2.0 spaces x 3 units =6.0 1.5 spots per 1 bedroom unit 1.5 spaces x 1 units =1.5 0.3 spots per unit for visitors 0.3 spaces x 4 units =1.2 Total spaces =8.7 -9 total spaces required / 9 provided -1 van accessible parking space required / 1 provided Building Height Summary Max # of Stories 3 Proposed # of Stories 3 Max Structure Height 24' (<3:12 roof slope) 30' (>3:12 roof slope) Proposed Building Height 20'-3" (<3:12 roof slope) 29'-11 1/4" (>3:12 roof slope) Building Setback Summary Front Setback Required (Provided) 20' (20'-1") Side Setback Required (Provided) 81.62' (.10) = 8'-2"(8'-3") Side Setback Required (Provided) x2 side = 16'-4" (16'-5") Utilities/Public Services Summary Water District Carlsbad Municipal Water District Proposed Water Demand 250 gal / day / unit Sewer District City of Carlsbad Proposed Sewer Demand 1 EDU / unit Master Drainage Basin B School District Carlsbad Unified School District Noise Study Noise study "CP Juniper Residential Development Interior Noise Report" has been completed by LDN Consulting, Inc. and included with submittal. Recommendations from report will be followed in order to comply with interior noise level limits per the City of Carlsbad. Exterior noise level limits are not applicable to this project. Earthworks Summary Remedial grading per recommendation of Geotechnical Report prepared by CW LaMonte. Proposed Disturbance 90% Remedial 50 CY (in-place at pavement areas) Proposed Cut 140 CY (incl. excavation for lower level) Proposed Fill 10 CY Net Export 130 CY (10% shrinkage factor) = 117 CY Stormwater Calculations proposed roof 3,776 sf proposed hardscape 1,827 sf proposed street 2,538 sf Total Proposed 8,141 sf total existing (3,945) Net New Proposed 4,196 sf (<5000 sf) See stormwater checklist and attached exhibits for additional documentation on area calculations. Traffic Volume Calculations 6 ADT x 4 units = 24 ADT OWNER CP Juniper, LLC Tyler Van Stright, Manager 235 Pine Ave Apt Q Carlsbad, CA 92008 tyler@jlcarchitecture.com (760) 521-0866 ARCHITECT JLC Architecture contact: Tyler Van Stright 250 N Cedros Avenue Solana Beach, CA 92075 tyler@jlcarchitecture.com (858) 436-7777 x2# SURVEY Sampo Engineering contact: Vince Sampo 1034 Second Street Encinitas, CA 92024 vince@sampoengineering.com (760) 436-0660 GEOTECHNICAL ENGINEER C.W. LaMonte Company, Inc. contact: Jerry Redolfi 4350 Palm Avenue #25 La Mesa, Ca, 91941 redof@flash.net (619) 997-9861 DIRECTORY VICINITY MAP PROJECT SITE GROSS BUILDING AREA Area Name Area Comments Unit A 419 SF 2- deck level Unit A 283 SF 3 - upper level Unit A 702 SF Unit B 556 SF 2 - deck level Unit B 465 SF 3 - upper level Unit B 1021 SF Unit C 436 SF 1 - ground level (garage) Unit C 920 SF 2 - deck level Unit C 366 SF 3 - upper level Unit C 523 SF 0 - lower level Unit C 287 SF 1 - ground level (guest suite) Unit C 193 SF 2 - deck level (office) Unit C 2724 SF Unit D 665 SF 2 - deck level Unit D 540 SF 3 - upper level Unit D 1205 SF Grand total 5652 SF ACOUSTICAL ENGINEER LDN Consulting contact: Jeremy Louden 446 Crestcourt Lane Fallbrook, CA 92028 jlouden@ldnconsulting.net (760) 473-1253 STRUCTURAL ENGINEER Lovelace Engineering contact: Brent Katsuyama 5930 Corner Stone Court Suite 100 San Diego, CA 92121 MIsrael@lovelaceeng.com (858) 535-9111 x301 ENERGY / T-24 Gallant Energy Consulting contact: Mark Gallant 508 W Mission Ave Ste 201 Escondido, CA 92025 mark@title-24.com (760) 743-5408 Type of Construction V-B (sprinklered) Occupancy Dwelling Units R-2 Garage U Carports S-2 Maximum Stories 3 (2 + 1 bonus story per 504.2) Maximum SF R-2 7,000 SF per story U 5,500 SF Occupancy Load Units A/B/D 2,930 sf x (200) = 15 Unit C 2,287 sf x (200) = 11 (Unit C calculated separately due to separate exit provided, see plans this page) Exits Required 1 per Table 1021.2(1) 4 units, <125' max travel distance (see plans) Fire Separation 1 hour between (S-2) and (R-2) 1 hour between dwelling units 1/2 hour between private garage (U) and (R-2) Sound Transmission Min 50 STC betweend dwelling units BUILDING CODE SUMMARY No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" pr e - d e d i c a t i o n p r o p e r t y l i n e Ju n i p e r A v e n u e 30'-0" (e) masonry wall onadjacent property 1 A-005 Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" (e) carport at adjacent property (e) masonry wall on adjacent property sandblasted 8x16 masonry units, stack bond configuration as shown w/ 2" cap (typical for all freestanding site walls) rought sawn cedar fence w/ black stain 42" max height within front setback 32'-5"47'-5"9'-4"2'-0 1/2"5'-4"2'-0"5'-4"2'-0"5'-4" 72" max height 1 A-005 Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 2 A-005 32'-11 1/2"(e) 10" VC sewer, slope = 0.28% per "Plans for Carlsbad Sanitary District Grand Avenue, et all", DWG118-9, sheet 14 of 28 See also improvement plan project No. 8-19, drawing No. 117-2 (n) 6" sewer lateral 2.0% 39'-11" railroad right of way Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:16:20 PM A-005 Site Sections / Elevations 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/8" = 1'-0" 2 Site Section 2 1/8" = 1'-0" 3 Site Elevation - East Fence Detail 1/8" = 1'-0" 1 Site Section 1 No. Description Date DN UP UP UP A (n) masonry wall / fence along east PL, see elevation mailbox 1 concrete, natural gray, broom finish 2 pea gravel 3 open wood/composite decking A KK 1 1 1 1 2 3 B KK KK KK LL P ON E D R K ON QZJ H I B B W (train on fence) E W (train on fence) F W (train on fence) W (train on fence) JJ 2 HH HX C (along ground) GG FF V AA CC FF Y 2(below trees) W(train on fence) W (at deck level planter) L(at deck level planter) HARDSCAPE LEGEND maintain vehicular site lines per Cal Transstandards at driveway apron. 150' LOS extends to CL of eastbound lane. Landscape to be maintained at 30" or less in height. (n) 5' tall masonry trash/recycling/yard waste enclosure (2 containers per type) Juniper Avenue (CL) 1 A (existing) MM MM JJ D RF (below tree) E F QZJ 2 2 B (below tree) 2 2 W (train above top of fence at deck area to provide screening between properties) 2 L (train on up wall) landscape area = 2,493 sf (potable water) hardscape area (material varies, see main plan) building footprint size per plan size per plan extents per plan extents per plan extents per plan N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:30 PM A-006 Site - Landscape Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/8" = 1'-0" 1 Site - Landscape Plan Statement of Expertise I am familiar with the requirements for landscape and irrigation plans contained in the city of Carlsbad’s landscape manual and water efficient landscape regulations. I have prepared this plan in compliance with those regulations and the landscape manual and agree to comply with all requirements when submitting construction documents. I certify that the plan implements those regulations to provide efficient use of water. _______________________________________________ Jean-Louis Coquereau, Architect Water Conservation StatementCarlsbad is a semi-arid “Mediterranean climate with an increasingly precious and limited water supply. The landscape for this project is therefore designed to exist, in large part, without artificial irrigation once plants have been established. Not surprisingly, California natives are well equipped to this task. Priority has been given to their use throughout the site. The notable exceptions are areas for fruit trees and a private garden. Where irrigation is provided is will be high efficiency as appropriate to the specific planting area. All plants have been located with north, south east and west exposure in mind such that the plants are well suited to their specific locations, sun exposure and relative soil moisture. Water Use Calculation Total landscape area is less than 2,500 SF. See water use map below. WELO calculations are not required. Fire Protection Plan Project is located outside of high severity fire zone. Project will comply with all applicable regulations resulting from project review. Maintenance Responsibility All landscaping on site will be privately maintained by the owner. Maintenance will be done in such a way as to provide a healthy growing environment for the various plants. Trash and other debris will be removed as required. Misc Requirements Landscape construction drawings will be required to show and label all utilities and provide appropriate screening. The plan shall provide that only low volume or subsurface irrigation shall be used to irrigate any vegetation within twenty-four inches of an impermeable surface unless the adjacent impermeable surfaces are designed and constructed to cause water to drain entirely into a landscaped area. 1/16" = 1'-0" 2 Water Use Map LANDSCAPE NOTES 0'4'8'16' No. Description Date UP UP UP UP UP UP 1 A-301 1 A-301 1 A-303 1 A-303 1 A-302 1 A-302 39'-11" 2 A-301 2 A-301 A-202 1 A-201 2 A-2011 A-202 2 line of deck ovhd line of bldg ovhd line of bldg ovhd see site plan for parking layout 44'-4 1/2" 403 SF C-Garage1 100 SF C-Bdrm142 100 SF C-Brdm243 176 SF C-Playroom40 252 SF C-Flex Room38 A-2031 bunk beds wardrobe wardrobe hooks / shelf towel bars curtain rod linencloset 2 A-303 2 A-303 1 A-304 1 A-304 wardrobe accessible threshold rqrd 44'-0" 101104 103 102 04 03 01 A-204 1 A-203 2 A-204 2 plumbing location at deck level ovhd (typ) 2 A-302 2 A-302 81 SF C-Kid's Bath41 (2' max) 1'-11" (2' max) 1'-11" (2' max) 1'-5" 2 A-101 43'-9"44'-3" 58'-9 1/2" (36" min) 3'-1" 1'-10 1/2" 3'-0 3/4" 3'-7 3/4" 6'-7" 3'-0" clr 10'-3"8'-8 1/2"4'-1"20'-6 3/4"15'-2 1/4" 2'-1 1/2"4'-0"2'-7"EQ EQ max 1.5" drop at threshold line of deck ovhd 4'-0"3'-0"3'-0" max 1.5" drop at threshold 3'-4" 3'-4" 3'-0" 3'-8" 46'-3" 44'-0" 9'-4 3/4" clr 10'-7" clr (30" min) 2'-8" clr (24" min) 2'-8" clr 4'-8 1/2" 2'-6" 3'-11 1/4" 4'-8" 2'-6" Lightwells required for egress 23'-0 1/2"20'-6 3/4"16'-2 1/4" 40'-5 1/2" 4'-8" 3'-0 3/4" EQ EQ 6'-8 3/4"2'-7 3/4"3'-2 1/2" 4'-4"6'-1 3/4" 9'-0 1/4"9'-0" 43'-11" 3'-6 1/2" 3'-3" 10'-5 1/4" 7'-2 1/4" 4'-11 1/4" 17'-7 1/2"30x42 clr 30x42 clr 6'-0 1/4" 3'-1 1/4" 10'-8 3/4"9'-4 1/2" align w door at deck level 7'-7 1/2"7'-6 3/4" wardrobe 02 2 A-304 2 A-304 202 205 204 206 207 203 113 114 201 SD CM see stair/ handrail/ guardrail notes on A-002 5/8" type "x" gyp board btwn garage and dwelling 1/2" gyp bd at underside of stairs where accessible SD CM SD SD see stair/ handrail/guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 R @ 6 1/2"17 R @ 6 1/2"7 R @ 7"8 R @ 7 1/2"15 EF EF EF Ground Level FF 44'-0" Lower Level FF 39'-11" Split Level FF 49'-0" (3' min clr) 3'-0" (44" max for egress) 34" 6" min clr waterproofing and french drain system per specifications 22.85' qualifies as "basement" 23.21' qualifies as "basement" 20.98' qualifies as "basement" 1.88' does NOT qualify as "basement" 7.50' qualifies as "basement"15.76' does NOT qualify as "basement" total perimeter 92.08' "basement" perimeter 74.53' 74.53' / 92.08' = 80.94% (>75%) "Lower Level " qualifies as "basement" as defined by City of Carlsbad for all height limit calculations Per 21.04.065. See bldg sections for additional documentation. N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:32 PM A-101 Ground Level Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Ground/Lower Level 1/2" = 1'-0" 2 Lightwell Detail GROSS BUILDING AREA Area Name Area Comments Unit A 419 SF 2- deck level Unit A 283 SF 3 - upper level Unit A 702 SF Unit B 556 SF 2 - deck level Unit B 465 SF 3 - upper level Unit B 1021 SF Unit C 436 SF 1 - ground level (garage) Unit C 920 SF 2 - deck level Unit C 366 SF 3 - upper level Unit C 523 SF 0 - lower level Unit C 287 SF 1 - ground level (guest suite) Unit C 193 SF 2 - deck level (office) Unit C 2724 SF Unit D 665 SF 2 - deck level Unit D 540 SF 3 - upper level Unit D 1205 SF Grand total 5652 SF 1/8" = 1'-0" 3"Basement" Diagram No. Description Date UP DN DN DN DN DN UP UP DN UP Washer Dryer 1 A-301 1 A-301 1 A-303 1 A-303 1 A-302 1 A-302 53'-4" 53'-4" 53'-4" 2 A-301 2 A-301 A-202 1 A-2011 A-202 2 3'-1" 5'-3" 3'-1" 46'-3" 30 SF C-Laundry2 146 SF C-Bdrm3/Office3 88 SF C-Entry4 315 SF C-Kitchen5 402 SF C-Living7 A-2031 storage below stairs 2 A-303 2 A-303 1 A-304 1 A-304 storage below stairs storage below stairs 53'-1 1/2" 105 106 107 109 110 111 06 10 11 09 12 13 08 14 15 18 07A-204 1 A-203 2 A-204 2 face of wall ovhd 19 05 2 A-302 2 A-302 390 SF B-Great Room 8 348 SF A-Great Room9453 SF D-Great Room10 19 SF C-Powder 11 20 SF B-Powder12 22 SF D-Powder13 20 SF A-Powder14 (2' max) 1'-11" (2' max) 1'-5" (2' max) 1'-11" 16 17 skylightovhd 12'-1" 47'-0" 1'-8" 20'-9" 26'-2 3/4" 3'-11 1/4" 4'-9 1/2" 1'-7"2'-0" 8'-9 1/2" 6'-4" 7'-6 1/2" 4 1/4" 2'-0" 3'-5" 8'-0" 7'-8 1/4" 7'-8 1/2" 2'-3 3/4" 19'-9 1/2"21'-2 1/2"18'-9 1/2" 59'-9 1/2" 5'-5 1/4"11'-0 1/4"2'-4" 1'-4 3/4"8'-3"1'-4 3/4" 15'-10 1/4"3'-11 1/4" 5'-4"6'-0" W L (see planting legend) (see planting legend) 108 22'-0 1/2"4'-10"14'-1 1/2"2'-7"3'-1 3/4" 26'-9 1/4" 7'-0" 15'-5 1/4" 7'-1 1/2" 56'-4" 2'-6" 9 3/4" 3'-7 3/4" 3'-4 1/4" 3'-5 1/4" 8'-10 3/4" line of roof ovhd line of roof ovhd line of roof ovhd 2'-0" 3'-11 1/4" 9'-9 1/2"49'-0" 58'-9 1/2" 4'-0"3'-0"8'-10 3/4"2'-7"4'-0"17'-4 3/4"9'-10"4'-5 3/4"6'-4"4'-4 3/4"3'-1 1/4" 3'-8" 4'-6 1/4" 4'-10" 4'-10" 2'-4 1/2" 3'-1" clr 3'-1" clr 3'-6" clr 3'-6" clr 1'-10" 4'-7" 10'-5 1/4" 4'-10" 5'-11 1/2" 7'-8" 4'-10" 2'-9 1/2" 6'-1 1/2" 3'-2 1/4" 3'-5 3/4" 3'-11 1/4" 3'-1" clr 3'-1" clr 3'-0" 3'-0"9'-9 3/4" 6 1/2" (24" min) 2'-0" 55'-0" 2 A-304 2 A-304 209 210 208 216 215 211 214 212 213 SD CM SD SD CM SD CM SD CM see stair/ handrail/ guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 49'-0" see stair/ handrail/ guardrail notes on A-002 6'-0 1/2"4'-2 3/4"8'-8 1/2"8'-7 3/4"9'-5 3/4"6'-0 1/2" 9'-2 1/4" 9'-9 1/4" 7'-11" covered entry (typ) see stair/ handrail/ guardrail notes on A-002 R @ 6 1/2"17 R @ 7 1/2"7 R @ 7"8 R @ 5 1/2"5 R @ 5 3/4"5 R @ 7 1/4"15 R @ 7 1/2"15 R @ 7 1/4"15 R @ 7 1/4"15 R @ 7 1/4"15 EF EF EF EF EF 1/4" / 12" N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:34 PM A-102 Deck Level Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Deck/Split Level GROSS BUILDING AREA Area Name Area Comments Unit A 419 SF 2- deck level Unit A 283 SF 3 - upper level Unit A 702 SF Unit B 556 SF 2 - deck level Unit B 465 SF 3 - upper level Unit B 1021 SF Unit C 436 SF 1 - ground level (garage) Unit C 920 SF 2 - deck level Unit C 366 SF 3 - upper level Unit C 523 SF 0 - lower level Unit C 287 SF 1 - ground level (guest suite) Unit C 193 SF 2 - deck level (office) Unit C 2724 SF Unit D 665 SF 2 - deck level Unit D 540 SF 3 - upper level Unit D 1205 SF Grand total 5652 SF No. Description Date DN DN DN DN 1 A-301 1 A-301 1 A-303 1 A-303 1 A-302 1 A-302 62'-6" 62'-6"2 A-301 2 A-301 A-202 1 A-201 2 A-2011 A-202 2 316 SF C-Master Suite44 7 7/8" / 12" storage over stairs stackedlaundry stacked laundry A-2031 open to below 2 A-303 2 A-303 1 A-304 1 A-304 storage/closet + stacked laundry over stairs (floor at 2-3') storage/closet over stairs (floor at 2-3')62'-6" 62'-6" 112 21 22 32 25 24 10 26 28 23 27 30 A-203 2 A-204 2 33 34 20 skylight ovhd 63'-6" top of parapet face of wall below enclosed deck (screening walls approx 5' tall) 66'-10" top of parapet 2 A-302 2 A-302 (2' max) 1'-11" (2' max) 1'-11" (2' max) 1'-11" (2' max) 1'-11" 123 SF A-Bdrm 15 46 SF A-Bath16 129 SF B-Bdrm117 128 SF B-Bdrm218 47 SF B-Bath19 114 SF D-Bdrm320 90 SF D-Bdrm221 123 SF D-Bdrm122 43 SF C-Bath123 45 SF D-Bath2 24 face of wall below 2'-8 1/4" 2'-0" 5'-5 1/4"11'-0 1/4"2'-4" 19'-9 1/2"21'-2 1/2"18'-9 1/2" 10'-1 1/4"6'-10" 6'-0" 1'-7 3/4" 52'-1 1/2" 6'-2 1/2" 26'-9 1/4" 7'-0" 18'-4 1/4" 2'-9" 10 1/2" 2'-4 3/4" 3'-10 3/4" 4 3/4" 2'-6" 3'-5 1/4" 8'-10 3/4" 3'-1" 11'-4 1/4" 2'-6 3/4" skylight ovhd skylight ovhd 3'-3 1/2" 5'-7 1/4" 2'-10 3/4" 3'-2 1/4" 3'-4" 3'-4 3/4" 2'-0"59'-9 1/2"2'-0" 19'-9 1/2"21'-2 1/2"18'-9 1/2" 2'-10"6'-0"2'-1"6'-7 3/4" 26'-9 1/4" 7'-0" 18'-4 1/4" 8'-8" 5'-9 1/4" 2'-8 1/2" 2'-6" 1'-11 1/4" 3'-4 3/4" 2'-4 1/2" 4'-10" 9'-6" 04 3'-7 1/4"4'-10" 11'-5 1/2"7'-4" 51'-9 1/2" 10'-11 1/2" 1'-8" 5'-10 1/4" 15'-4 1/4" 28'-11" (24" min) 2'-0" 8'-2 3/4" 7'-1 1/2" 6'-9" 7'-0 1/4" 3'-2 1/2" 3'-6 3/4" 8'-4 1/2" 7'-11 1/2" 4'-0" 2'-8 1/2" 6'-4" 7'-1" 9 3/4" 2'-0" 4'-0" 3'-5 1/4" face of gutter ovhd trellis for climbing plants face of wall below HVAC equipment for all units downspout (typ) line of roof ovhd face of gutter ovhd 5'-10 1/4" 11'-5" 3'-11 1/4" 3'-2 1/4" 11'-4 3/4" 2'-4 3/4" 11'-11 1/4" 2'-1" 4'-10" 4'-6 3/4" 4'-10" 2'-0 1/4" 1'-4 3/4"8'-3"1'-4 3/4" 59'-9 1/2" 63'-9 1/2" 2 A-304 2 A-304 217 238 229 226 225 223 222 218 219 220 232 231 230 221 235 240 227 228 224 237 236 234 233 239 SD CM SD CM SD CM SD CM SD SD SD SD SD SD SD see stair/ handrail/ guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 see stair/ handrail/ guardrail notes on A-002 29 31 EF EF EF EF EF 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" string lights omitted for clarity N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:36 PM A-103 Upper Level Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Upper Level GROSS BUILDING AREA Area Name Area Comments Unit A 419 SF 2- deck level Unit A 283 SF 3 - upper level Unit A 702 SF Unit B 556 SF 2 - deck level Unit B 465 SF 3 - upper level Unit B 1021 SF Unit C 436 SF 1 - ground level (garage) Unit C 920 SF 2 - deck level Unit C 366 SF 3 - upper level Unit C 523 SF 0 - lower level Unit C 287 SF 1 - ground level (guest suite) Unit C 193 SF 2 - deck level (office) Unit C 2724 SF Unit D 665 SF 2 - deck level Unit D 540 SF 3 - upper level Unit D 1205 SF Grand total 5652 SF No. Description Date 1 A-301 1 A-301 1 A-303 1 A-303 1 A-302 1 A-302 2 A-301 2 A-301 A-202 1 A-201 2 A-2011 A-202 2 A-2031 3" / 12" 3" / 12" 2 A-303 2 A-303 1 A-304 1 A-304 A-203 2 A-204 2 03 02 01 3" / 12" 3" / 12" face of wall below roof below roof below face of wall below wall below 73'-1" 72'-11 1/2" 2 A-302 2 A-302 (2' max) 1'-2 3/4" (2' max) 1'-2 3/4" (2' max) 10" (2' max) 1'-2" roof below 11 3/4"6" 9" (2' max) Roofing - Asphalt Shingle Roofing - Asphalt Shingle 2 A-304 2 A-304 N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:16:37 PM A-104 Upper Roof Plan 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Upper Roof Level GROSS BUILDING AREA Area Name Area Comments Unit A 419 SF 2- deck level Unit A 283 SF 3 - upper level Unit A 702 SF Unit B 556 SF 2 - deck level Unit B 465 SF 3 - upper level Unit B 1021 SF Unit C 436 SF 1 - ground level (garage) Unit C 920 SF 2 - deck level Unit C 366 SF 3 - upper level Unit C 523 SF 0 - lower level Unit C 287 SF 1 - ground level (guest suite) Unit C 193 SF 2 - deck level (office) Unit C 2724 SF Unit D 665 SF 2 - deck level Unit D 540 SF 3 - upper level Unit D 1205 SF Grand total 5652 SF No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 109 28 2627 14 13 01 12 11 72'-11 1/2" 43'-0 1/2" (below ridge line) 29'-11" 2'-0" intrusion per 21.46.120 30" offset from (e) grade (max height within setback beyond 2'-0" intrusion) Stucco 02 Stucco 01 Stucco 02 Stucco 01 steel - painted 03 Galvanized Steel Roofing - Asphalt Shingle Stucco 01 Galvanized Steel Aluminum - Dark Bronze Anodized Metal - Stainless Steel Aluminum - Dark Bronze Anodized 2 A-302 29 7 1/2" typ 11" typ Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 104 101 110 102 111 30 15 (e) grade (e) grade = (n) grade (n) grade 20'-6" outline of basement below grade 30" offset from (e) grade (max height within setback beyond 2'-0" intrusion) 3" 12" 3" 12" 23 Stucco 01 Stucco 02 Stucco 01 Stucco 02 Stucco 01 wood - painted 01 Stucco 01 Glass - Dual, Low-E Aluminum - Dark Bronze Anodized espalier tree (see landsape plan) espalier tree(see landsape plan) 2 A-304 16 02 Stainless Steel Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:16:47 PM A-201 Perimeter Elevations 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 East Elevation 1/4" = 1'-0" 2 South Elevation No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 19 34 33 32 18 04 03 01 outline of basement below grade 43'-7 1/4" (below ridge line) 29'-5 3/4" 73'-1" 30" offset from (e) grade (max height within setback beyond 2'-0" intrusion) 2'-0" intrusion per 21.46.120 Stucco 02 Roofing - Asphalt Shingle Galvanized Steel Stucco 01 Stucco 02 Stucco 01 wood - painted 01 Stucco 01 Aluminum - Dark Bronze Anodized 2 A-302 2 A-101 Galvanized Steel (e) fence/wall on adjacent property 31 17 11" typ 5 1/2" typ 5 3/4" typ Stainless Steel for climbing vines (see landsape plan) Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 10 20 05 43'-0 1/4" (at bldg face) 29'-11 1/4" 72'-11 1/2" (n) grade at bldg face43'-5 1/2" (at parking surface beyond) 29'-7 1/2" 73'-1" 3" 12" 3" 12" Galvanized Steel Stucco 01 Stucco 02 wood - painted 01 Blackened Cedar Metal - Stainless Steel steel - painted 01 66'-10" top of parapet at end of deck (e) grade at building face Stucco 02 Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Galvanized Steel wood - painted 01 pending retaining wall and fence at neighboring property trash enclosure wood - painted 01 Roofing - Asphalt Shingle 2 A-304 CMU, 8x16 Stack Bond steel - painted 03 Galvanized Steel Blackened Cedar Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:16:57 PM A-202 Perimeter Elevations 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 West Elevation 1/4" = 1'-0" 2 North Elevation mailbox No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 112 105 22 21 06 0302 Stucco 01 Roofing - Asphalt Shingle Galvanized Steel Galvanized Steel Stucco 02 steel - painted 01 Aluminum - Dark Bronze Anodized Stucco 01 2 A-302 1/2" gyp bd at underside of stairs where accessible 17 7" typ 10 1/2" typ 7 1/2" typ 10 1/2" typ 6'-8" min clr cables for climbing plants (see planting plan) Stainless Steel Galvanized Steel C-Living7 C-Playroom40 Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 25 24 08 107106 09 Roofing - Asphalt Shingle Galvanized Steel Stucco 02 Stucco 01 Galvanized Steel steel - painted 01 Stucco 01 steel - painted 03 HVAC equipment 2 A-302 cables for climbing plants (see planting plan) Stainless Steel Galvanized Steel C-Garage1 C-Kitchen5C-Entry 4 Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:05 PM A-203 Courtyard Section/Elevations 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Courtyard - East Section/Elevation 1/4" = 1'-0" 2 Courtyard - West Section/Elevation No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 Stucco 02 steel - painted 01 Galvanized Steel Roofing - Asphalt Shingle 2 A-304 6 1/2" typ 1'-0" typ D-Bdrm122 C-Bath123 B-Bdrm117 B-Great Room8 Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 07 103 Stucco 01 Stucco 01 Stucco 01 Stucco 02 Stucco 02 Stucco 02 2 A-304 108 43'-4 1/4" B-Bdrm117 C-Bath123 B-Great Room 8 Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:13 PM A-204 Courtyard Section/Elevations 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 Courtyard - South Section/Elevation 1/4" = 1'-0" 2 Courtyard - North Section/Elevation No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" 1 A-303 2 A-303 1 A-304 49'-1" 43'-1" 73'-1" 63'-6"63'-6" (<50%) 3'-10 1/4" (>50%) 4'-1" (e) grade = (n) grade pending retaining wall and fence at neighboring property C-Living7 C-Kitchen5 C-Bdrm3/Office3 C-Flex Room38C-Garage1 C-Playroom40C-Brdm243 (e) grade (e) grade 2 A-304 10 1/2" typ 6 1/2" typ 6'-8" min clr Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-303 6'-8" min clr 2 A-303 1 A-304 (e) grade (n) grade 73'-1"72'-11 1/2" 44'-0" 29'-1" 43'-1" 29'-10 1/2" HVAC equipment 49'-1" 43'-1" pending retaining wall and fence at neighboring property C-Master Suite44 C-Entry4 C-Laundry2 B-Great Room8 C-Garage1 C-Living 7 C-Bdrm142 C-Kid's Bath41 B-Bdrm218 (<50%) 3' - 10" (>50%) 4' - 1" (<50%) 3' - 11" (>50%) 4' - 0"(e) grade 2 A-304 7 1/4" typ 11" typ 8'-0" 8'-2" min clr Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:14 PM A-301 Building Sections 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 East-West Section 1 1/4" = 1'-0" 2 East-West Section 2 No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 (e) grade (n) grade 73'-1" 72'-11 1/2" 43'-7 1/4" 29'-5 3/4" 43'-2 1/2" (existing) 29'-9" 49'-1" 43'-1" 44'-1 1/4" 48'-5" pending retaining wall and fence at neighboring property D-Bdrm221 D-Great Room10 A-Great Room9 A-Powder14 6'-8" min clr 2 A-304 7 1/4" typ 10" typ 9'-2" Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-303 2 A-303 1 A-304 (e) grade (n) grade 73'-1" 72'-11 1/2" 43'-6" 29'-7" 43'-0 1/2" 29'-11" 49'-1" 43'-1" pending retaining wall and fence at neighboring property D-Bdrm320 D-Bath224 D-Great Room10 A-Great Room9 A-Bdrm15 A-Bath16 2 A-304 8'-0" Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:15 PM A-302 Building Sections 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 East-West Section 3 1/4" = 1'-0" 2 East-West Section 4 No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 (e) grade 44'-0" 19'-6" (e) fence on adjacent property (n) grade 30" offset from (e) grade (max height within setback beyond 2'-0" intrusion) 2 A-302 63'-6" C-Master Suite44 D-Bdrm122 D-Bdrm221 D-Bdrm320 D-Great Room10 C-Living7 C-Brdm2 43 C-Bdrm1 42 (>50%) 4' - 1" (<50%) 3' - 10" (<50%) 3' - 10" (>50%) 4' - 1"(e) grade 44'-0" 39'-11" Ground Level FF 44'-0" Deck Level FF 53'-4" Lower Level FF 39'-11" Upper Level FF 62'-6" Split Level FF 49'-0" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 (e) grade(e) grade = (n) grade 43'-10" 19'-5" (n) grade 2 A-302 63'-6" (<50%) 3'-10" (>50%) 4'-1" (e) masonry wall on adjacent property C-Master Suite44 C-Living7 C-Playroom40 D-Great Room10 D-Bath224C-Bath123 D-Powder13 (e) grade 6'-8" min clr 7 1/4" typ 10 1/2" typ Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:16 PM A-303 Building Sections 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 North-South Section 1 1/4" = 1'-0" 2 North-South Section 2 No. Description Date Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 (e) grade(e) grade = (n) grade 43'-8 3/4" 19'-9 1/4" outline of bldg beyond HVAC equipment 2 A-302 63'-6" 51'-4 1/4" (8'-2" min) 8'-3 1/2" 43'-0 3/4" (e) masonry wall on adjacent property C-Kitchen5 C-Entry4 C-Garage1 (n) grade 1/4" / 12" at drainage plan below decking flat decking over sleepers (ripped) Ground Level FF 44'-0" Deck Level FF 53'-4" Upper Level FF 62'-6" Upper Roof Plate 70'-3" 1 A-301 1 A-302 2 A-301 2 A-302 (e) grade (e) grade = (n) grade 43'-8 3/4" 19'-9 1/4" 63'-6" 43'-0 3/4" (e) masonry wall on adjacent property (n) grade B-Bdrm218 B-Bdrm117 A-Bdrm15 A-Great Room9B-Great Room8C-Bdrm3/Office3 C-Flex Room38 8'-2" 8'-0" Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: SDP 14-03 / CDP 14-04 7/19/2014 12:17:17 PM A-304 Building Sections 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 1/4" = 1'-0" 1 North-South Section 3 1/4" = 1'-0" 2 North-South Section 4 No. Description Date N Project number Purpose Drawn by Checked by These drawings and specifications are the property and copyright of the architect and shall not be used on any other work except by agreement with the architect. Export Date: pr o j e c t n o r t h SDP 14-03 / CDP 14-04 7/19/2014 12:17:19 PM A-601 Window/Door Schdl, Glazing Details 13018 city submittal - CDP / SDP TVS JLC CP J u n i p e r A p a r t m e n t s 38 5 J u n i p e r A v e n u e , C a r l s b a d , C A 9 2 0 0 8 Glazing in the following locations should be of safety glazing material in accordance with Section R308.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface. c) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. d) Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: i) Exposed area of an individual pane is greater than 9 square feet, and: ii) Exposed bottom edge is less than 18 inches above the floor, and: iii) Exposed top edge is greater than 36 inches above the floor, and: iv) One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. e) Glass railings, regardless of height, above a walking surface (including structural baluster panels and nonstructural in-fill panels). f) Walls and fences used as the barrier for indoor and outdoor swimming pools and spas when all of the following conditions are present: i) The bottom edge of the glazing is less than 60 inches above the pool side of the glazing, and: ii) The glazing is within 5 feet of a swimming pool or spa deck area. g) Walls enclosing stairway landings or within 5 feet of the bottom and top of stairways where the bottom edge of the glass is less than 60 inches above a walking surface. SAFETY GLAZING NOTES DOOR SCHEDULE - EXTERIOR # Function Type Level Sill Height Width Height Material: Frame Material: Panel Material: Glass Manufacturer Model Comments 101 Exterior DOUBLE-GLASS Ground Level FF 0"6'-0" 7'-2" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E 102 Exterior GARAGE - OVERHEAD, GLASS 2wx4h Ground Level FF 0" 12'-4" 7'-4"Aluminum - Dark Bronze Anodized Glass 103 Exterior GARAGE - OVERHEAD Ground Level FF -1" 16'-0" 7'-0"Aluminum 104 Exterior SINGLE-GLASS Ground Level FF 6"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E 105 Exterior SINGLE-GLASS Deck Level FF 0"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Frosted 106 Exterior SINGLE-GLASS Deck Level FF 0"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Frosted 107 Exterior SINGLE-GLASS Deck Level FF 0"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Frosted 108 Exterior SINGLE-GLASS Deck Level FF 0"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Frosted 109 Exterior SINGLE-GLASS Deck Level FF 0"3'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E 110 Exterior SLIDER-GLASS_OXXO Deck Level FF 0" 12'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E 111 Exterior SLIDER-GLASS_OX Split Level FF 0"6'-0" 8'-0" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E 112 Exterior SLIDER-GLASS_OX Upper Level FF 6"5'-0" 6'-8" Aluminum - Dark Bronze Anodized Aluminum - Dark Bronze Anodized Glass - Dual, Low-E note sill height 113 Exterior SINGLE FRAMELESS Ground Level FF -11" 3'-0" 6'-0"fence - vertical wood planks exterior gate 114 Exterior SINGLE FRAMELESS Ground Level FF 0"3'-0" 6'-0"fence - vertical wood planks exterior gate DOOR SCHEDULE - INTERIOR # Function Type Width Height Material: Frame Material: Panel Material: Glass Manufacturer Model Comments 201 Interior SINGLE 2'-8" 6'-8"wood - painted 01 wood - painted 01 202 Interior SINGLE 3'-0" 6'-8"wood - painted 01 wood - painted 01 min 20 min rated, slef-closing / self latching 203 Interior SINGLE 3'-0" 6'-8"wood - painted 01 wood - painted 01 min 20 min rated, slef-closing / self latching 204 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 205 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 206 Interior SINGLE 2'-2" 6'-8"wood - painted 01 wood - painted 01 207 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 208 Interior SINGLE 2'-0" 6'-8"wood - painted 01 wood - painted 01 209 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 210 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 211 Interior CARRIAGE DOOR - SINGLE - top offset 3'-0" 6'-8"wood - painted 01 212 Interior SINGLE 2'-2" 6'-8"wood - painted 01 wood - painted 01 213 Interior SINGLE 2'-2" 6'-8"wood - painted 01 wood - painted 01 214 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 215 Interior SINGLE 2'-2" 6'-8"wood - painted 01 wood - painted 01 216 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 217 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 218 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 219 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 220 Interior SINGLE FRAMELESS 2'-0" 6'-10"Glass 221 Interior SLIDER-INTERIOR-FRAMELESS_3-Panel 9'-0" 6'-8"wood - painted 01 222 Interior SINGLE 2'-4" 6'-8"wood - painted 01 wood - painted 01 223 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 224 Interior SINGLE 2'-0" 6'-8"wood - painted 01 wood - painted 01 225 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 226 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 227 Interior SLIDER-INTERIOR-FRAMELESS_3-Panel 9'-0" 6'-8"wood - painted 01 228 Interior POCKET 2'-6" 6'-8"wood - painted 01 wood - painted 01 229 Interior SINGLE FRAMELESS 2'-0" 6'-10"Glass 230 Interior SINGLE FRAMELESS 2'-0" 6'-10"Glass 231 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 232 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 233 Interior SLIDER-INTERIOR-FRAMELESS 5'-0" 4'-8"wood - painted 01 234 Interior SLIDER-INTERIOR-FRAMELESS 5'-0" 4'-8"wood - painted 01 235 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 236 Interior SLIDER-INTERIOR-FRAMELESS 5'-0" 6'-8"wood - painted 01 237 Interior SLIDER-INTERIOR-FRAMELESS_3-Panel 9'-0" 6'-8"wood - painted 01 238 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 239 Interior SINGLE 2'-6" 6'-8"wood - painted 01 wood - painted 01 240 Interior SINGLE FRAMELESS 2'-0" 6'-10"Glass 1.See plans and elevations for multi-unit configuration dimensions and operation type. 2.Egress Windows must have an net clear opening area of at least 5.7 square feet (5.0 square feet for grade-floor openings), with the minimum net clear opening width of 20" and the minimum net clear opening height of 24". 3.For Egress Windows, the sill height shall not exceed 44" above the floor. 4.Natural ventilation shall be provided for all habitable rooms, with the minimum openable area to the outdoors of 4% of the floor area being ventilated per Section R303.1. 5.Contractor to verify in field net clear opening dimensions for all existing and new windows before ordering. WINDOW NOTES *see elevations for multi-unit mulling configuration / sloped & radius shapes / operation type* WINDOW SCHEDULE # Level Sill Width Height Area Material: Frame Material: Glass Tempered Glass Manufacturer Model Comments 01 Ground Level FF 3'-0"6'-0"3'-10"23 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 02 Ground Level FF 6"4'-0"6'-10"27 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 03 Lower Level FF 2'-8"2'-6"4'-4"11 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 04 Lower Level FF 2'-8"2'-6"4'-4"11 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 05 Deck Level FF 0"6'-0"8'-0"48 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 06 Deck Level FF 0"1'-6"6'-10"10 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 07 Deck Level FF 0"1'-6"6'-10"10 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 08 Deck Level FF 0"1'-6"6'-10"10 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 09 Deck Level FF 0"1'-6"6'-10"10 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 10 Deck Level FF 2'-6"8'-3"10'-2"84 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 11 Deck Level FF 3'-6"8'-0"2'-0"16 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 12 Deck Level FF 3'-6"2'-0"3'-4"7 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 13 Deck Level FF 0"6'-4"8'-0"51 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 14 Deck Level FF 3'-6"2'-0"3'-4"7 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 15 Deck Level FF 0"6'-4"6'-10"43 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 16 Deck Level FF 0"4'-0"6'-10"27 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 17 Deck Level FF 0"2'-0"3'-10"8 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 18 Split Level FF 2'-6"2'-6"8'-8"22 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 19 Deck Level FF 0"8'-10 3/4" 8'-0"71 SF Aluminum 01 Glass - Dual, Low-E tbd tbd see elevation for clarification on width alignment to adjacent windows 20 Upper Level FF 0"6'-0"6'-10"41 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 21 Upper Level FF 5'-0"4'-10"1'-10"9 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 22 Upper Level FF 3'-6"2'-6"3'-4"8 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 23 Upper Level FF 3'-0"4'-10"3'-10"19 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 24 Upper Level FF 3'-0"4'-10"3'-10"19 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 25 Upper Level FF 3'-0"4'-10"3'-10"19 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 26 Upper Level FF 4'-6"4'-0"2'-4"9 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 27 Upper Level FF 3'-6"2'-0"3'-4"7 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 28 Upper Level FF 4'-6"6'-4"2'-4"15 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 29 Upper Level FF 4'-6"4'-0"2'-4"9 SF Aluminum 01 Glass - Dual, Low-E tbd tbd 30 Upper Level FF 3'-0"6'-0"3'-10"23 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 31 Upper Level FF 3'-0"2'-6"3'-10"10 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 32 Upper Level FF 3'-0"2'-9"3'-10"11 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 33 Upper Level FF 0"2'-6"6'-10"17 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer 34 Upper Level FF 0"6'-0"6'-10"41 SF Aluminum 01 Glass - Dual, Low-E tbd tbd must meet egress requirements, confirm compliance w manufacturer SKYLIGHT SCHEDULE - EXISTING AND NEW # inside curb width outside curb width inside curb length outside curb length Material: Frame Material: Glass tempered? operable? interior blinds?Manufacturer Model Type Comments Comments 01 1'-2 1/2" 1'-5 1/2" 3'-10 1/2" 4'-1 1/2"Aluminum 01 Glass - Dual, Low-E Yes No No Velux FCM 1446 ICC Report NER-216, Hallmark Test #B3620.01-109-44-r1/r2 02 1'-10 1/2" 2'-1 1/2" 1'-10 1/2" 2'-1 1/2"Aluminum 01 Glass - Dual, Low-E Yes Yes No Velux VCE/VCM 2222 ICC Report NER-216, Hallmark Test #B3620.01-109-44-r1/r2 03 1'-10 1/2" 2'-1 1/2" 2'-10 1/2" 3'-1 1/2"Aluminum 01 Glass - Dual, Low-E Yes Yes No Velux VCE/VCM 2234 ICC Report NER-216, Hallmark Test #B3620.01-109-44-r1/r2 04 1'-10 1/2" 2'-1 1/2" 1'-10 1/2" 2'-1 1/2"Aluminum 01 Glass - Dual, Low-E Yes Yes No Velux VCE/VCM 2222 ICC Report NER-216, Hallmark Test #B3620.01-109-44-r1/r2 No. Description Date MATERIAL PALETTE Wall Finish: Stucco 01 (White) Wall Finish: Stucco 02 (Dark Gray) Exposed Wood Framing: Wood - Painted 01 (White) Windows and Doors: Aluminum - Dark Bronze Anodized Masonry Walls: 8x16 Stack Bond, Sandblasted Gray w/ 2” Wall Cap Fencing, Slatted Screens: Rough Sawn Cedar w/ Black Stain Gutters, Flashing, Downspouts: Galvanized Steel Guardrails: Galvanized Steel w/ Stainless Steel Cables Exposed Structural Steel Posts: Steel Painted 03 (Rust Red) Roofing: Asphalt Shingles (Light Gray) JLC Architecture CP Juniper Apartments | daytime view from northeast (end of cul-de-sac) JLC Architecture CP Juniper Apartments | nighttime view from northeast (end of cul-de-sac) JLC Architecture CP Juniper Apartments | daytime view from northwest JLC Architecture CP Juniper Apartments | nighttime view from northwest JLC Architecture CP Juniper Apartments | daytime view from southwest (backyard) JLC Architecture CP Juniper Apartments | nighttime view from southwest (backyard)