Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2401 MOUNTAIN VIEW DR; ; AS980224; Permit
5/2/25, 8:55 AM AS980224 Permit Data City of Carlsbad AUTOMATIC SPRINKLER-RESI 2401 MOUNTAIN Job Address: VIEW DR Permit Type: ASR Parcel No: 1551016500 Lot #: 0 Reference No.: Permit No: AS980224 Status: ISSUED Applied 12/16/1998 Approved: 2/26/1999 Issued: 2/26/1999 PC #: Inspector: Project Title: BUENA VISTA LAGOON LOTS/O/H 2 SF HOMES W/PRIVATE DR, TENNIS COURTS Applicant: Owner: FIRE SAFETY LEVY JOHN C JR P 0 BOX 462371 ESCONDIDO CA 760 744-8580 Fees ($) Add'l Fees ($) Total ($) Balance ($) 190 0 190 0 about:blank 1/1 Pc51?O 2'It-f ------------------------------------------------------------------------------- SUMMARY OF HYDRAULIC CALCULATIONS FOR LEVY RESIDENCE CARLSBAD CA ------------------------------------------------------------------------------- Submitted By FIRE SAFETY P.O.BOX 462371 ESC. CA -------------------------------------- Design Specifications Water Supply Information System Demand Density : 0.000 82.00 psi @ 0.00 gpm 37.00 psi Design Area: 0.00 69.70 psi @ 200.00 gpm 23.8 gpm Total Demand: 23.8 gpm @ 37.00 psi System safety factor: 44.75 psi Notes: _t, j, jOp Lo-s rricu jc m' ccim 4, 75PsI List of Fitting Abbreviations Example: "E2TC" = one Std. Elbow, two Std. Tee , and one Check Va Code:Description Code:Description Code:Description Code:Description A: Alarm Va H:45Ell 0: V: B : Butt'flyVa I :Cross P : W C: Check Va J: Q: X: D : DryPipeVa K : R : Y E : Std. Elbow L : Longtrnell S : Z F : Deluge Va M : T : Std. Tee G: Gate Va N: U: Calcs By: J.M. Checked: 11-20-98 Page: 1 Ser:*310046* Hypercaic Program by Crowley Design Group, (215)-337-7060 Summary of Sprinkler and Hose Flows Job No:010 LEVY RESIDENCE Design density: Supplied flow and pressure is based on 37.00 psi available at supply 81.76 psi is actually available Ref. PRESSURE K FLOW Percent Ref. Pt. Pt Pv Pn Factor Actual Minimum Excess Pt. AOl 6.98 6.98 4.40 11.6 11.6 0.00-o AOl A03 7.59 7.59 4.40 12.1 11.6 4.3% A03 R02 37.00 37.00 0.00 5.0 5.0 0.001 R02 Caics By: J.M. Checked: 11-20-98 Page: 2 Ser:*310046* Hypercaic Program by Crowley Design Group, (215)-337-7060 Flow and Pressure Summary Job No:010 LEVY RESIDENCE Elev. REF. Flow Pt ft. POINT gpm psi 27.50 AOl << 11.6 << 6.98 28.50 A02 << 11.6 << 6.71 27.50 A03 << 12.1 << 7.59 28.50 A04 << 23.8 << 7.51 28.50 A05 << 23.8 << 11.92 8.50 A06 << 23.8 << 25.01 8.50 A07 << 23.8 << 30.42 8.50 R01 << 23.8 << 31.02 Pf Pe Pt REF. Elev. psi psi psi POINT ft. 0.16 -0.43 6.71 A02 28.50 0.80 0.00 7.51 A04 28.50 0.35 -0.43 7.51 A04 28.50 4.41 0.00 11.92 A05 28.50 4.41 8.68 25.01 A06 8.50 5.41 0.00 30.42 A07 8.50 0.60 0.00 31.02 R01 8.50 2.51 3.47 37.00 R02 0.50 FRICTION Length Fitting 1.00 E 10.00 T 1.00 T 15.00 ET 20.00 E 13.00 2E2T 1.00 E 8.00 CG IT: Caics By: J.M. Checked: 11-20-98 Page: 3 Ser:*310046* Hypercalc Program by Crowley Design Group, (215)-337-7060 Path Summary Printout for LEVY RESIDENCE Job No:010 11-20-98 System:GUEST Drawing:1 OF 2 Path No:1 Remote to Supply Principal path Feeds Path:2 at Pt:A04 Ref Elev. Pressure (psi) K Flow (gpm) Veloc Diam. Actual Fitting Fitti Pt. ft. Pt Pv Pn Factor Added Total fps in. Length Summary Lengt AOl 27.50 6.98 6.98 4.40 11.6 11.6 4.51 1.025 1.00 E 2.0 A02 28.50 6.71 6.71 11.6 4.51 1.025 10.00 T 5.0 A04 28.50 7.51 7.51 12.1 23.8 9.22 1.025 15.00 ET 7.0 A05 28.50 11.92 11.92 23.8 9.22 1.025 20.00 E 2.0 A06 8.50 25.01 25.01 23.8 9.22 1.025 13.00 2E2T 14.0 A07 8.50 30.42 30.42 23.8 9.22 1.025 1.00 E 2.0 R01 8.50 31.02 31.02 23.8 8.80 1.049 8.00 CG 6.0 P02 0.50 37.00 Path No:2 Grid Line Fed by path No.1 Ref Elev. Pressure (psi) K Flow (gpm) Veloc Diam. Actual Fitting Fitti Pt. ft. Pt Pv Pn Factor Added Total fps in. Length Summary Lengt A03 27.50 7.59 7.59 4.40 12.1 12.1 4.71 1.025 1.00 T 5.0 A04 28.50 7.51 I