HomeMy WebLinkAbout2777 LOKER AVE WEST; ; AS110136; Permit5/2/25, 3:20 PM AS110136 Permit Data City of Carlsbad Sprinkler Permit 2777 LOKERAV Job Address: WEST Permit Type: SPRINK Parcel No: 2090813000 Lot #: 0 Reference No.: PC #: Permit No: AS110136 Status: PENDING Applied 9/21/2011 Approved: 9/27/2011 Issued: 9/27/2011 Inspector: Project Title: SUPERBRAND T.I. Applicant: TOTAL FIRE PROTECTION, INC. STE. 244 1611-AS. MELROSE DR. VISTA, CA 760-525-4329 Owner: CALIFORNIA BUTCHERS PENSION TRUST FUND C/O JAMES THOMAS 2777 LOKER AVE W CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 264 0 264 0 about:blank 1/1 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. I PROPERTY NAME Su - Date I /0/31,1201/ PROPEYA5RESS J Zolcew /b4,) C,q. 'I zooS PLANS ACCEPTED 2WYCOYING AUTkQRITY('S) NA M Sbood, 4- ac ADDRESS INSTALLATION CONFORMS TO ACCEPTED PLANS YES EQUIPMENT USED IS APPROVED DYES IF NO, EXPLAIN DEVIATIONS 0 NO 0 NO INSTRUCTIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN YES 0 NO HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS 0 YES CARE AND MAINTENANCE INSTRUCTIONS Z YES NFPA 25 YES 0 NO 0 NO 0 NO LOCATION OF SYSTEM SUPPLIES BUILDING: MAKE MODEL YEAR OF MANUFACTURE K FACTOR ____________ QUANTITY TEMPERATURE RATING __________ I 12- - ITS Z7_ PIPE AND FITTINGS Type of Pipe: -GJMM an& Sch3O Type of Fittings: Ductile Iron 40 a"Im ALARM VALVE OR FLOW INDICATOR ALARM DEVICE MAXIMUM TIME TO OPERATE THRU TEST CONNECTION TYPE MAKE MODEL MIN. SEC. DRY PIPE OPERATING TEST DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. TIME TO TRIP THRU TEST CONNECTION WATER PRESSURE AIR PRESSURE TRIP POINT AIR PRESSURE TIME WATER REACHED TEST OUTLET* ALARM OPERATED PROPERLY MIN. SEC. PSI PSI PSI MIN. SEC. YES NO Without Q.O.D. 0 0 With Q.O.D. 0 0 IF NO, EXPLAIN: MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. (OVER) OPERATION 0 PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED 0 YES 0 NO DETECTING MEDIA SUPERVISED 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS 0 YES 0 NO IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO, EXPLAIN DELUGE & PREACTION 0 YES 0 NO VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. 0 1 0 0 0 HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi TEST (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. DESCRIPTION PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR _2_ HRS. IF NO, STATE REASON: DRY PIPING PNEUMATICALLY TESTED 0 YES 0 NO EQUIPMENT OPERATES PROPERLY 0 YES 0 NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? TESTS ZYES 0 NO DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST I CONNECTION OPEN WIDE PSI TEST I CONNECTION: PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING OTHER EXPLAIN VERIFIED BY COPY OF THE U FORM NO. 85B 0 YES 0 NO FLUSHED BY INSTALLER OF UNDER- GROUND SPRINKLER PIPING 0 YES 0 NO BLANK NUMBER USED LOCATIONS: NUMBER REMOVED TESTING 0 GASKETS WELDED PIPING YES 0 NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-3? 0 YES 0 NO DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-3? Z YES 0 NO WELDING DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? 0_YES [I NO CUTOUTS (DISCS) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? 0 YES 0 NO HYDRAULIC NAME PLATE PROVIDED IF NO, EXPLAIN: DATA NAMEPLATE Z YES 0 NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: - REMARKS NAME OF SPRINKLER CONTRACTOR: i. Fire Protection 1_, Inc. TESTS WITNESSED BY FOR PROPERTY OWNER (SIGNED) TITLE DATE SIGNATURES FOR ONJ4CTOR (SIGNED) TITLE FOR LOCAL FIRE MARSHAL (SIGNED) TITLE DATE FOR RESPONSIBLE MANAGING EMPLOYEE (SIGNED) TITLE DATE ADDITIONAL EXPLANATION AND NOTES (BACK) MATERIAL DATA SUBMITTAL SUPERbrand 277 W. Loker Ave, Suite E Carlsbad, CA 92008 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 strap Tee 13-19 Sprinkler Tyco TY-FRB Recessed Sprinkler 20 Hanger Afcon Fig. 300 Ring Hanger 21 Hanger Afcon Fig 655 All Thread Rod 22 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, Ca 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpiohncgmaiI.com -t - Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. '1']jiPJ1H]iI!I Schedule • Dyna-Thread's inside diameter is up • With its increased strength and lighter to 3.6% larger than Sch-40 giving it weight, Dyna-Thread reduces superior hydraulics. And, when used installation fatigue and is ideal for in combination with Dyna-Flow pipe, retro-fit applications. down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> 9 Listed Approved Listed Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pm-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcsl Wti1.itt (21') WVLift (24') WUlIft (25') In; mm in; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 274 2.0 2.60 70 887 1013 105i 1W 1.408 1.870 2,54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 tqco/Flowcontml ()dhed 16100 S. Lathrop• Harvey, IL 60426 11350 Norcom Rd. ' Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna-Thread° Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here • , 1 •ct I Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula 'ABF". ISpecifications NPS Nominal I.D. Wt. WI. (1120 FIlled) PCs/ WVI.Itt (21') WUI.lft (24') Wt/LitI (25') In; mm In; mm Lbs/Ft;Kg/ni Lbs/Ft Kg/rn Lift Lbs;Kg Los; Kg Lbs;Kg 1" 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1Y4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114. 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as @ <> () are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BIT is Listed Approved Listed manufactured with Black lacquer coating. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3-4 tqCC Fire & Building 11products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco® Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI 131.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. in general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, For incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular ourøose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. tregistered trademark of E. I. du Pont de Nemours and Company or its affiliates. TFPI7IO Page 1 of 10 JANUARY, 2008 Page 2 of 10 TFPI7I0 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part ON (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 88781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 DN25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 0N32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 0N40 (49,3) (0,42) 2 2.25 1,55 86283 0N50 (57,1) (0,70) 2-1/2 2.69 2.70 13 FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW 1.68 Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 1.94 1.00 TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 0N65 (68,3) (39,6) (1,49) 86204 (49,3) (25,4) (1,22) 86782 I truly irosqu %V us AV FIGURE 812 90 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. ON (mm) (mm) (mm) (mm) Number (kg) 3/4 x 1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x112 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (142) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25x20 (35.1) (36,6) (17,5) (22,4) (0,24) 1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4x3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32x20 (36,6) (41.4) (19,0) (26,9) (0,34) 1-1/4x1 1.56 1.68 0.88 1.00 0.77 86214 0N32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40x20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.56 86218 0N50 x 25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65x50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 0 TFPI7I0 Page 5of 10 Nominal Pipe Size Approx. ANSI Inches Weight Part DN Lbs. Number (kg) 1/2 0.18 72779 DN15 (0108) 3/4 0.26 72778 DN20 (0,11) 1 0.44 72755 0N25 (0,20) 1-1/4 0.54 72754 DN32 (0,24) 1-1/2 0.71 72753 0N40 (0,32) 2 1.15 72752 0N50 0,52) 2-1/2 2.29 12758 0N65 1,04) T_ i_fl ffN UJiI FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING 1.63 TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 A B Approx. A B Inches Inches Weight Part Inches Inches (mm) (mm) Lbs. Number (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 (28,7) (14,2) (0,15) (35,1) (7,9) 1.31 0.75 0.50 86341 0.56 (33,3) (19,0) (0,23) (41,4) (14,0) 1.50 0,81 0.85 86230 1.75 0.38 (38,1) (20,6) (0,38) (44,4) (9,7) 1.75 1.06 1.30 86231 2.00 0.56 (44,4) (26,9) (0,59) (50,8) (14,0) 1.94 1.19 1.63 86232 2.19 0.75 (49,3) (30,2) (0,74) (55,6) (19,0) 2.25 1.50 2.63 86233 2.63 1.13 (57,1) (38,1) (1,19) (66,8) (28,7)± 2.69 1.56 4.55 86234 3.00 0.75 (6813) (39,6) (2,06) (76,2) (19,0 TFPI7I0 Page 6of 10 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C 0 E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part ON (mm) (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 1-1I2x11/4x1I2 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN40x32x15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0.47) 86257 1-1/2x1-1/4x3/4 1.50 1.44 175 0.75 0.75 1.19 1.10 DN40 x 32 x 20 (38,1) (36,6) (44,5) (19,0) (19,0) (30 (0,50) 86258.1) 1-1/2x 1-1/4x 1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 DN40x32x25 (41,4) (39.7) (46.0) (22,4) (22,4) (28,7) (0,59) 86259 1-1/2x1-1/4x2 2.19 2.13 2.00 1.4.4 1.44 1.25 1.94 86260 0N40 x 32 x 50 (55.6) (54.1) (50,8) (36.6) (36.6) (57,1) (0,88) 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40 x 40 x 15 (36.6) (36,6) (42,9) (17,5) (17,5) (28.7) (0.52) 1-112x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38.1) (44,4) (19,0) (19,0) (30,1) (0.56) 1-112x1-112x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 0N40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2 x 1-1/2 x 1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN4O x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30 (0,68) 86264,1) 1-1/2x 1-1/2x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 DN40 x 40 x 50 155,51 (55,5) (50,8) (36,6) (36.6) (31,7) (0,91) 86265 2 xl x 2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 DN50x25x50 (57,2) (50,8) (57,2) (38,1) (33,3) (38,1) (0.99) 66266 2 x 1-1/4 x 2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DN50 x 32 x 50 (57,2) (64 (57,2) (38,1) 86267,1) (36,6) (38,1) (1,05) 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (38,1) (36,6) (47.8) (19,0) (17,5) (33.3) (0,68) 2 x 1-1/2 x 314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 DN50x40x20 (41,4) (38,1) (49,3) (22,4) (19,0) (3510) (0,73) 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.55 86270 DM50 x 40 x 25 (44,5) (41,4) (50,8) (25.4) 1 (22,4) (33,3) (0.75) 2x1-112x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 DM50 x 40 x 40 (52,4) (49,2) (55,5) (33,3) (30.2) (36,6) (0.92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (57.1) (55,5) (63,5) (38.1) (36.6) (38,1) (1.07) 2x2x1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 86222 0N50 x 50 x 1 (38,1) 1 (38,1) (47.8) (19,0) (19,0) (33.3) (0,68) 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49,3) (22,4) 1 (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DM50 x 50 x 25 (44,5) (44,5) (50.8) (25,4) (25.4) (33,3) (0,86) 86224 2x2x1414 1.88 1.88 2.13 1.13 1.13 1.44 2.05 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28,7) (36,6) (0.93) 86225 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 DN50x50x40 1 (50,8) 1 (50,8) (55,6) (31.8) (31.8) (38,1) (0,96) 86226 2x2x2-112 2.63 2.63 2.38 1.75 1.88 1.44 3.67 DN50 x 50 x 65 (66.8) (66,8) (60,5) (44.5) (47.8) (36.6) (1,66) 86227 2-1/2 x 2 x 3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 DN65x50x20 (445} (41,4) (58,7) (15,9) (22,4) (44,5) (1,01) 86274 TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO r1rams- gI•1 n - ii•i FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Size Figure 820 Figure 830 Figure 719 ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 0.88 0.15 72776 1.88 0.81 0.47 88207 0.94 0.10 86292 DN15 (22,4) (0.06) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0110) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 033 72824 2.19 0.81 1,08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 DN32 (33,3) (0.24) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 0N40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 0N50 (38,1) (0,43) (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - 0N65 44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7I0 Page 9of 10 EA A FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPUNG TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15x15 (38,1) (0,09) 1/2x 112 2.00 0.27 72980 - - - - - - - ON15x15 (50,8) (012) 3/4 x 3/4 1.50 0.22 72981 - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - DN20x20 (50,8) (0,14) 3/4 x 1/2 - - - - 1.75 0.69 0.38 86772 DN20 x 15 (43,2) (17,5) (0j7) I x1/2 - - 1.06 0.22 72726 1.69 0.50 0.38 86228 0N25 x 15 (26,9) (0,10) (42,9) (12,7) (0117) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 (26,9) (0,08) (43,2) (12,7) (0,24) 1-114x1 - - 1.19 0.31 72763 - - - - DN32 x 25 (30,2) (0,14) 1-1/2x1 - - 1,25 0.53 72757 - - - - DM40 x 25 (31,7) (0,24) 1-1/2x1-114 - - 1.25 0.35 72764 - - - - DM40 x 32 (31,7) (0110) 2x1 - - - 1.38 0.75 72759 * - - - DN50 x 25 (35,1) (0,34) 2 x 1-1/4 - - - 1.38 0.69 72761 - - - - DN50x32 (35,1) (0,31) 2x1-1/2 - 1.38 0.62 72775 - - - - DN50x40 (35,1) (0,28) tqCC /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description- UL See Fire Protection L Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Figure 40-5 Strap isaneconomicalattemative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap maybe used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las withtheapp/icablestandards of the National Fire Protection Association, in addition to the standards ofanyotherauthorities ha v/ag jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturer should be contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: 'Clear rust inhibitive coating 'Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade 'E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicablestandards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The instalfing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Are Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand properly installed and maintained under normal use and service. This warranty will expireten (10)years from data of shipment byTyco Fire Products, No warranty is given for products or components manufactured by companies not affillated byownershipwilh Tyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found bylyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforft, any otherobligationinconnectionwith the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibleforsprinklersystem designerrorsorinaccwateorincompletetnformaflon supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUBgTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCOFIREPRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL 1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Page 1 of 2 September 2004 (B TFPI 720 Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 1V4° X /2° 2.00 1.50 3.50 1.20 1/16 0.84 50.8 38.1 88.9 30.5 1 30.2 0.4 1'/4" x 2.00 1.50 3.50 1.20 13/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/40 x 1' 2.31 1.68 3.50 1.20 1/i6 1.13 58.7 42.7 1 88.9 30.5 30.2 0.5 1'/2' X 720 2.12 1.62 3.50 1.32 13'ie 0.84 53.8 41.1 88.9 33.5 1 30.2 0.4 l/ x 3/0 2.12 1.62 3.50 1.32 1/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1 1/20 X 1' 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 1 88.9 33.5 30.2 0.5 20x1/2 2.36 1.86 3.74 1.55 13'16 0.88 59.9 47.2 95.0 39.4 1 30.2 0.4 2 x 3/0 2.36 1.86 3.74 1.55 1/l6 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2'x r 2.67 2.04 3.74 1.55 1/i 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/20 X 1/20 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 1 30.2 0.4 21k0 x 3/ 4 0 2.61 2.11 4.25 1.80 13& 0.99 66.3 53.6 .7 30.2 0.4 21/2" x 10 2.92 2.29 4.25 108.0~45.7 0 1/l6 1.21 _______ 74.2 58.2 108.0 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1'I4"X 1 8 1V20 x 1 6 2'x 1 6 21/2 x 1 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP1 720 Figure 40.5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:12) General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqCU IF/re & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TV-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1 /2 inch NPT) or Style 40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TV-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1151 - Upright 2.81K, 1/2"NPT 1Y1251 - Pendent 2.81K, 1/2"NPT TY3151 - Upright 5.6K, 1/2"NPT TY3251 - Pendent 5.61K, 1/2"NPT TY4151 - Upright 8.0K, 3/4"NPT TY4251 - Pendent 8.0K, 3/4"NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT APRIL, 2006 ESCUTCHEON PLATE SEATING .* SURFACE 1/2,, 1 NPT NOMINAL SSU* MAKE-IN DEFLECTOR OOUF~__ I _ WRENCH _ _F_ 'I' 2-1/4" (57,2 mm) 1-9/16 (39,7 mi Page 2 of 8 TFPISI DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 5 - Compression 7 - Bushing orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TV-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2- (55, 7/16(11,1 mm) STYLE 10 ** NOMINAL RECESSED MAKE-IN ESCUTCHEON SSU* NPT ruM ('TC'iP 6* 6" nm) RECESSED PENDENT UPRIGHT CROSS SECTION 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. PENDENT 1 - Frame 3 - Sealing 2 - Button Assembly FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3 151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPI5I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** IPOLYESTER LEAD COATED I WAX COATED I WAX OVER LEAD COATED 2.8 1/2' NPT PENDENT (TV1251) and UPRIGHT (TY1151) 135°F/57°C Orange 1,2,3 N/A 155°F/68"C Red 175"F/79°C Yellow 200°F/93"C Green 286°F/141°C Blue 360°F/1 82°C Mauve 1,2 5.6 1/2" NPT PENDENT (1Y3251) and UPRIGHT (TY3151) 135°F/57"C Orange 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 155"F/68°C Red 175"F/79°C Yellow 200°F193°C Green 286°F/141°C Blue 1**,2**, 3** 5** 2"", 3** 5** 360°F/1 82°C Mauve N/A RECESSED PENDENT (1Y3251)* Figure 4 135°F/57"C Orange 1,2, 3,4, 5 I I 1,2, 4, 5 I N/A 155°F/68°C Red 175"F/79°C Yellow 200"F/93°C Green 286°F/141°C Blue 1,2 80 NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135"F/57°C Orange 1,2, 3,4,5,6, 7 1,2,5 1,2,3,5 1,2,5 155"F/68°C Red 175"F/79"C Yellow 2007/93"C Green 286"F/141°C Blue 1*',2°", 3** 5** 2°, 5** 360°F/182°C Mauve N/A RECESSED PENDENT (TY4251)* Figure 5 135°F/57"C Orange 1, 2, 3,4, 5 N/A 155°F168"C Red 175°F/791C Yellow 200°F/93"C Green 286°F/141"C Blue 1,2 8.0 1/2" NPT PENDENT (1Y4951) and UPRIGHT (TY4851) 135°F/57°C Orange 1, 2, , N/A 155°F/68°C Red 175°F/79"C Yellow 200°F/93°C Green 286"F/141"C I Blue 360°F/1 82°C Mauve NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/40 Total Adjustment Recessed Escutcheon, as applicable. ** 150°F/66°C Maximum Ceiling Temperature. TABLE A, LABORATORY LISTINGS AND APPROVALS 8 TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 28 PENDENT (TY1251) 1/2 and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (TYII5I) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2" UPRIGHT (TY3151) OR NPT 175 PSI (12,1 BAR) RECESSED PENDENT (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 80 PENDENT(TY4951) 1/2" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/ps11/2 (40,3 LPM/barll2) K = 5.6 GPM/p5i112 (80,6 LPM/barl/2) K = 8.0 GPM/ps1112 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. C 0 0 MOUNTING SURFACE CLOSURE SERIES 1/8" (3,2 mm) 1-1/4" (31,8 mm) 3/4"(19,1 mm) FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING fli r LP I C. 1/8" (3,2 mm) I CLOSURE SERIES 1-5/16" (33,3 mm)t TY-B 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE Page 6 018 TFPI5I 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1(O LJIPt. (73,0 mm) 3/4" (19,1 mm) I 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) 7:;1 I MOUNTING _- PLATE WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360F/182°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ftibs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con nections. Higher levels of torque ma distort the sprinkler inlet and cause WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH TFPI5I Page 7 of 8 heated rod, in order to prevent the by brushing it with a soft bristle brush. installer from being burned. ,,.,, ., +-. ,... .,..,.i ..i...... leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the The Series TV-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or HUL IJV VAVI LU VUIU UItI- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 61 Page 8 of 8 TFPI5I TY1251 PIN 57-XXX-X-XXX - MODEL/SIN I TY1 151 1 T 3 9 7 6 8 SPRINKLER I TEMPERATUF j_ RATING 135 135°F/57C 155 155F/68°C 175 175°F/79C 200 200F/93C 286 286F/141°C 360 360F/182°C 286°F/141°C MAX. 530 2.8K UPRIGHT (1/2"NPT) NATURAL BRASS 590 2.8K UPRIGHT (1/2"NPT) WHITE POLYESTER 570 5.6K UPRIGHT (1/2NPT) WHITE (RAL9010)* 571 5.6K PENDENT (1/2"NPT) CHROME PLATED 590 8.0K UPRIGHT (314"NPT) LEAD COATED 591 8.0K PENDENT (3/4'NPT) - WAX COATED - 560 8.01< UPRIGHT (1/2'NPT) 1 WAX OVER LEAD 286FI141°C MAX. - 561 1 8.0K PENDENT (1/2°NPT) TABLE C PART NUMBER SELECTION SERIES TV-B PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fled or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a oar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table C). Recessed Escutcheon: Specify: Style (specify 10 or 40 ) Re- cessed Escutcheon with (specify*) fin- ish, PIN (specify*). * Refer to Technical Data Sheet TF13770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 1/2 3/8 400 10 3/4 g 400 20 10 400 25 10 400 32 10 400 40 10 2 318 400 50 10 21/2 3/8 600 65 10 3/8 600 80 10 31/2 318 600 10 4 3/8 1000 100 10 5 1250 125 12 6 1250 150 12 1250 200 .21 Order Part #300m Note: 1/2 Ring Hanger not <FM> approved ( D MAM IAc!n 300 RING HANGER ze A)US I thru 4 inch pipe 112 and 3/4 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H.-171(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru4 inch: * Offset edge for EASY pipe insertion. 1 thru8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 /Acn 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 1 2420 7/8 3770 1 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. MIX ( D For vertical use. Install in center of lower face. Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance WOOD - 3/ i-tical flT11Th Use #14 Nut Driver (Item #100) Approvals I Item # I Model I Shk Lgth Shk Dia I FMTest I Load, lb. 1 ULTest I Load lb. I ijjj' I I Pipe Size I I Actual Pullout I I Box Qty I 10 I CST.75 I 1/4 I I 564#-6P1y I 100 NFPA 11 IGST10 I 1 1/4 I I I 210# - 7/16 0S131 I I 670# - 3/4" Ply I 100 UL.FM.NPA 12 GST 20 2 1/4 9400 850# 3/4-2 1/2 17600 - Fir 100 UL-NFPA I * 27 GST 25-380I 21/2 3/8 1500# 4 I 21130 - Fir I o 100 I 13 I GST30 3 1/4 14750 I500# 3/4-4 I 20600-Fir NFPA I 403 IGST40 I 4 1/4 21800-Fir I 50 NFPA I 14 GST 60 6 1/4 2230# - Fir 50 WOOD V)IRod 1&YT1IMount) Use #14SWNutDriver (Item #101) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty 8 GST2 2 1/4 1760# - Fir 50 7.00 500 * 06 GST 2.5-380 21/2 3/8 2113# - Fir 50 10.00 500 15 CST3 3 1/4 2275# - Fir 50 10.50 500 16 GST4 4 1/4 2180#-Fir 50 10.60 1 500 17 CST 6 6 1/4 2230# - Fir 50 10.95 1 500 ii #I4SW (Item #101-red) Sidewinders & Sammys 112" rod Not less than 2" nominal width (11/2") a, 5-' m NE di Note: Screws must be installed with appropriate nu t driver to comply with warranty Page 4 I" WOOD - 1/4" Rod (NITerticalAlount) Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Box Qty Weight (1(10) Case Q' GST.750 ler 20 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 IGST300 3 114 1 100 7.50 1000 24 IGST 600 6 1 1/4 1 50 1 9.00 1 500 WOOD - Sammys TJI Joist! Truss Consult truss manufacturer for recommended installation point. Pre-drilling may be required for items #27 and #06. Tools available on page 9. 401. Wood Flooring q Wood Joist i #14 (Item 9100-black) Sammys 114", 318' rod 6~affffyg Not less than 3* nominal width - (1-1/2") up to 3-1/2" pipe; not lees than 3"(2-11M nominal width 4'& 5' pipe 4 Floor Joist - It Minimum 2-1/2' from bottom for I branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. 'No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. 'Reduces installation costs. Made in the U.S.A. watch a video clemenofrat ion at reeew.iwvibuildex.com V HIM 1/4' 8019957 SWG 200 1/4x 2 1725 (Fir) 25 125 3/88020957 SWGIO tl4x1 622 (Fir) 300 25 125 I IEL 3)8' 8021957 SWG 20 114 x 2" 1725 (Fir) 1050 25 125 3/8 8073925 1725(Ffr) 850 25 125 3/8"* 8022925 SWG 25-380 3/8 x 2-1/2' 2249 (Fir) 1500 25 125 #14SWRed r 3/8 8023925 SWG30 - 114x3 1884 (Fir) 25 125 Nut Driver Part # 8114910 * May require pee-drilling; consult joist manufacturer IN 'Eliminates distortion of threaded rod. Accommodates up to 3 /2' x 12 pitch roof. 'Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. ma #14 SH OrangE Nut Driver Part #82Th91( 3/8' 8139957 SH-GST2O 1/4 x 2" 1257 (Fir) 3/8 8141957 SH-GST3O 1/4 x3 1720 (Fir) 1903 Dire. Lumber 4. 3/8 8269957 SH-GST/CST2O 5/16x1-3!4' 1406@45°off vertical Dim. Lumber 903 Dim. Lumber 1/2' 8303957 Sl-t-GST/CST 2.0 5/16x 1-3/4' 1406 @ 45°off vertical Dim. Lumber - May require pre-drilling; consult joist manufacturer. 1500 850@45° 25 125 25 125