Loading...
HomeMy WebLinkAbout6301 ALEXANDRI CIR; ; FA160049; Permit5/1/25, 3:18 PM FA160049 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA160049 Job Address: 6301 ALEXANDRI CR Status: ISSUED Permit Type: FALARM Applied 8/29/2016 Parcel No: 2159301801 Approved: 8/29/2016 Lot #: 0 Reference No.: Issued: 8/29/2016 PC #: Inspector: Project Title:' 6301 ALEXANDRI CR REPLACE FA SYSTEM-BLDG 1 Applicant: Owner: BAY ALARM COMPANY RILEY CAPITAL L L C 4883 RONSON CT SUTE C P0 BOX 807 SAN DIEGO, CA 92111 SOLANA BEACH CA 714-719-9334 L Fees ($) Add'I Fees ($) Total ($j Balance ($) [ 258.5 0 258.5 0 about:blank 1/1 BRINDISI RESIDENTIAL FIRE ALARMS BLDG# ADDRESS CB# FA# 1 6301 ALEXANDRI OR CB992420 FA160049 2 6307 ALEXANDRI CIR CB003689 FA160051 3 6319 ALEXANDRI CIR CB000291 FA160052 4 6341 ALEXANDRI CIR CB000337 FA160054 5 6355 ALEXANDRI CIR CB001106 FA160053 6 6369 ALEXANDRI CIR CB001107 FA160055 7 6377 ALEXANDRI CIR CB001169 FA160056 8 639O ALEXANDRI CIR CB001170 FA160057 9 6334ALEXANDRICIR CB001171 FA160058 10 6403 ALEXANDRI CIR CB001281 FA160059 11 6417 ALEXANDRI CIR CB001282 FA160060 12 6431 ALEXANDRI CIR CB001443 FA160061 13 6444 ALEXANDRI CIR CB001444 FA160062 14 6457 ALEXANDRI CIR CB001877 FA160063 15 6470 ALEXANDRI CIR CB001878 FA160064 16 6481 ALEXANDRI CIR CB001883 FA160065 17 6489 ALEXANDRI CIR CB001884 FA160066 SEE PERMIT FA160049 6301 ALEXANDRI CIR FOR CALCS & PLANS BRINDISI HOA-FA REPLACEMENT FOR 17 BLDGS. BAY ALARM CORP. 9-6-16 BLDG# ST. ADDRESS STREET CB# FA# COST 6301 ALEXANDRI CR- CB992420 FA160049 $258.50 2 6307 ALEXANDRI CR CB003689 FA160051 $146.00 3 6319 ALEXANDRI CR CB000291 FA160052 $146.00 4 6341 ALEXANDRI CR CB000337 FA160054 $146.00 5 6355 ALEXANDRI CR CB001106 FA160053 $146.00 6 6369 ALEXANDRI CR CB001107 FA160055 $146.00 7 6377 ALEXANDRI CR CB001169 FA160056 $146.00 8 6390 ALEXANDRI CR CB001170 FA160057 $146.00 9 6334 ALEXANDRI CR CB001171 FA160058 $146.00 10 6403 ALEXANDRI CR CB001281 FA160059 $146.00 11 6417 ALEXANDRI CR CB001282 FA160060 $146.00 12 6431 ALEXANDRI CR CB001443 FA1600611 $146.00 13 6444 ALEXANDRI CR CB001444 FA160062 $146.00 14 6457 ALEXANDRI CR CB001877 FA160063 $146.00 15 6470 ALEXANDRI CR CB001878 FA160064 $146.00 16 6481 ALEXANDRI CR CB001883 FA160065 $146.00 17 1 6489 JALEXANDRI CR CB001884 IFA1600661 $146.00 TOTAL:j $2,594.50 BUILDING ADDRESSES BUILDING NO. ADDRESS 1 6301, 6303, 6305 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 2 6307, 6309, 6311, 6313, 6315, 6317 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 3 6319, 6321, 6325, 6327, 6329, 6331 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 4 6341, 6343, 6345, 6347, 6349, 6351 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 5 6355, 6357, 6359, 6361, 6363, 6365 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 6 6369, 6371, 6373 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 7 6377, 6379, 6381, 6383, 6365, 6367 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 8 6390, 6392, 6394, 6396, 6398, 6400 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 9 6334, 6336, 6338 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 10 6403, 6305, 6307, 6309, 6311, 6313 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 11 6417, 6419, 6421, 6423, 6425, 6427 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 12 6431, 6433, 6435, 6437, 6439, 6441 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 13 6444, 6446, 6448, 6450, 6452, 6454 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 14 6457, 6459, 6461, 6463, 6465, 6467 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 15 6470, 6472, 6474, 6476, 6478, 6480 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 16 6481, 6483, 6485 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 17 6489, 6491, 6493, 6495, 6497, 6499 ALEXANDRI CIRCLE, CARLSBAD, CA 92011 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 PROTECTED PREMISE Brindisi at Aviara HOA Carlsbad, Ca 92011 MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 921111(800)470-1000 Contractor License # 880138 'A16Oo t'7 +0 rcw000 0000 - Search dmpatarms Powerfut addressable fire system Proven reliability suitable for commercial and industrial installations On-Board 10/100 Network Communication Full range of zone expansion, communication, and relay output capability Flash Updateable: No more firmware chips to replace Adaptive Technology1M - Cost-effective supervised cellular backup DMP XR150FC/XR550FC Series panels deliver true flexibility and expandability to cover all your fire needs. XRI50FC/XR550FC SERIES COMMERCIAL FIRE PANELS SYSTEM FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR55OFC Up to 142 two-wire smoke detector or fire initiating zones on XR1 5OFC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .7 Amps 12 VDC supervised bell output Up to 506 fully-programmable Form C relays Serial 3 Digital Dialer or CID reporting to multiple receivers Eight communication paths between the panel and Central Station Built-in remote or on-site feature upgrade capability 12.000 event buffer Multi-lingual menus available byL...__.----- Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality—Minimum programming XR'I 5ODNFC/XR55ODNFC SYSTEM FEATURES All above listed System Features On-board Ethernet connection for Network Monitoring1M Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available __ - The XR150DFC and XR550DFC provide basic fire monitoring for any single site application. The XR1500NFC and XR5500NFC panels provide all the same basic fire monitoring as the XR1500FC and XR5500FC enhanced by the on-board Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: CONTROL PANEL The XR1 50FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DAd. NET or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. XR1 5OFC/XR55OFC TYPICAL NOTIFICATION/ANNUNCIATION 12 or 24 VDC NAC 1 Strobe Mini-Horn 12 or 24 VOC NAC 2 Power Supply 505-12 or other 12124V0C UL Commercial Fire Approved Power Supplies Any expansion device I Loop 1 Fire Command can operate on SLC Loop Centers 1 or 630F Fire Command Center FLEXIBLE COMMUNICATION The XR15ODNFC and XR5500NFC has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character usef, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR1505C and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path. the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. EEl EIGHT COMMUNICATION PATHS Create, configure, and manage up to eight communication paths between the panel and Central Station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the Central Station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignal, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR1 50FC and XRSSOFC provide up to 570 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on-board and four on the 715 Module, plus eight panel burglary zones. Up to 60 zones are available on 15 keypad addresses and up to 100 zones are available on each built-in LX_BusTM using Expansion Modules. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XRI50FC/ XR550FC system. Up to three Class B modules can be mounted within the FACR Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the panel response to fire, burglary, panic and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX-Bus for Missing. Overlapping and/or Extra zones, and much more, all from any DMP LCD keypad. OUTPUTS The XR1 5OFC and XRSSOFC allow tIie-use. of two SPOT relay outputs and four open collector outputs, that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched- ground outputs. MULTI-LINGUAL DISPLAYS For additional flexibility, keypads attached to the XR1 50FC and XR550FC panels can display keypad Status List and User Menu text using multiple languages. The user has the option to select the language to use. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location and other zones can be programmed to display and be monitored at different keypad locations. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® WindoWSTM. The XR1 SOFC and XR550FC include an interface connection for installers to use to connect a laptop computer. FLASH UPDATEABLE The XRI50FC and XR550FC panels accept software updates from a remote location using Remote LinkTM software. When new XR1 SOFC/XR55OFC feature updates release, perform the flash update remotely. FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds afterthe reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. It1 630F LCD Remote Fire Command EXPANSION MODULES 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class-B Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion 716 Output Expansion, 4 Form C relays. 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs CELLULAR COMMUNICATORS 263C CDMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA+ Cellular Communicator (All require a 381 cable) AUXILIARY MODULES 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style 0 Class A Initiating Circuit Module 893A Dual Phone Line Module POWER SUPPLIES 505-12/LX 5 Amps @ 12 VDC 505-12L 5 Amps @12VDC 505-12A 5 Amps ©12VDC PULL STATIONS 850 Series Pull Stations SMOKE/HEAT DETECTORS 521 B/BXT Conventional Smoke, Clean Me 521 U(/LXT Addressable Smoke/Heat. CleanMe ACCESSORIES 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18 Coax Extension 431 Output Harness 861 Power Distribution Module CENTRAL STATION RECEIVERS SCS-1 R Network Enabled Receiver Compatable with Central Station Receivers that accept Standard CID. DD. or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS Two5) IlOOX Receiver 1100XH High Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165H5 Commercial Smoke/Heat Detector with Sounder 1181 Post Indicator Valve (UL) 1182 Outside Screw and Yoke Valve Supervisory Switch (UL) 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Alarm Monitoring Module Command Center Module Advanced Reporting Module Account Groups Module Link Server Application SYSTEM SPECIFICATIONS Primary Power (included) 16 VAC 56 VA transformer Secondary Power 12 VDC Battery Models 365, 366, 368 or 369 Output Rating Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For UL installations, total bell, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw 180mA Enclosure: Material Cold-rolled steel (Red) ORDERING INFORMATION XR1500FC-R XR150 Fire Control Panel XR1 5ODNFC-R XR1 50 Fire Control Panel with Network LISTINGS AND APPROVALS Refer to the XR150FC/XR550FC Installation Guide (LT-1297), XR150FC/ XR550FC Programming Guide (LT-1232) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For approval information, access www.dmp.com and select Compliance. XR55ODFC-R XR550 Fire Control Panel XR550 Fire Control Panel with 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 800.641A282 I dmp.com Designed. Engineered & Assembled in Springfield. Missouri I - AI_I_AI I 6.8 Power Requirements During AC power failure, the XRI 50FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. ALL devices must be taken into consideration when calculating the battery standby capacity. The following table lists the panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. Standby Battery Power Calculations Standby Current Alarm Current XR150FC/XR550FC Series Control Panel Qty 1 x 174mA 174 mA Qty 1 x 217mA 217 mA Relay Outputs 1-2 (ON) Qty _______ 30mA Qty _______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones 1-8 Qty ______ 1.6mA _____ Qty ______ 2mA* Active Zones 9-10 Qty _______ 4mA Qty _______ 30mA 2-Wire Smoke Detectors Qty ______ 0.1mA Qty ______ 0.1mA Panel Bell Output 1 500mA mA 893A Dual Phone Line Module Qty x 12mA Qty x 50mA 263C CDMA Cellular Communicator - Qty x 13mA Qty x 13mA 263H HSPA+ cellular communicator Qty x 24mA Qty _______ x 28mA 277 Buzzer Module Qty x 5mA Qty _______ x 5mA 1 100X Wireless Receiver Qty - x 46mA Qty x 46mA 1100XH Wireless High Power Receiver Qty x - 160mA Qty ______ x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty x 34mA All four relays active - - 138mA 138mA 865 Style Y or Z Notification Module Qty x 26mA Qty x 85mA 866 Style W Notification Module Qty x 45mA Qty x 76mA 867 LX-Bus Style W Notification Module Qty x 30mA Qty _______ x 86mA 869 Dual Style 0 Initiating Module Qty x 25mA Qty x 75mA 630F Remote Fire Command Center Qty x 63mA Qty x 92mA 7060/7160 Thinline/7060AAqualite Keypad Qty x 72mA Qty x 80mA 7063/7163 Thinline/7063AAqualite Keypad Qty x - 85mA Qty x lOOmA 7070/7170 Thinline/7070AAqualite Keypad Qty ______ x 72mA Qty x 87mA Active Zones (EOL Installed) 1.6mA Qty x 2mA* 7073/7173 Thinline/7073AAqualite Keypad Qty x 85mA Qty x lOOmA Active Zones (EOL Installed) 1.6mA Qty x 2mA* 7872 Graphic Touchscreen Keypad Qty x 145mA Qty x 215mA Active Zones (EOL Installed) - 1.6mA Qty x 2mA* 7873 Graphic Touchscreen Keypad Qty x 143mA Qty x 243mA Active Zones (EOL Installed) - 1.6mA Qty _______ x 2mA 734 Wiegand Interface Module Qty x 1 5mA Qty x 15mA Active Zones (EOL Installed) Qty x 1.6mA Qty x 2mA Annunciator (ON) Qty x 20mA 734N Wiegand Interface Module Qty x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty x 20mA Wiegand Reader Qty x 200mA Qty x 200mA 734N-WiFi Wiegand Interface Module Qty x 146mA Qty x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty ______ x 2mA* Annunciator (ON) Qty x 20mA Wiegand Reader - Qty x 200mA Qty x 200mA Copy Sub-Totals to next page Sub-Total Standby ______mA Sub-Total Alarm ______mA *Based on 10% of active zones in aLarm. Digital Monitoring Products XRI50FC/XR550FC Series Installation Guide 10 6/5/14 DMP Commercial Fire UL listed control panels WILL NOT display a GROUND FAULT MESSAGE but rather a trouble condition on the LCD display. For DMP Commercial Fire UL listed control panels, Ground Faults are annunciated locally at the LCD display and transmitted to the Central Monitoring Station as a trouble condition as required. See the following. UL 864 Control Units and Accessories for Fire Alarm Systems 3.46 GROUND FAULT - A circuit impedance to ground sufficient to result in the annunciation of a trouble condition. NFPA 722010 23.5 Performance of Initiating Device Circuits (IDC) 23.5.2 An open or ground condition shall result in the annunciation of a trouble signal. 23.6 Performance of a Signaling Line Circuit (SLC) 23.6.2 An open, short circuit, or ground fault shall result in the annunciation of a trouble signal. 23.7 Performance of Notification Appliance Circuits (NAC) 23.7.2 An open or ground condition shall result in the annunciation of a trouble signal. Terry Shelton, MBA I Director of Technical Design Digital Monitoring Products I dmp.com 417.831.93621 Fax 417.447.9698 2500 N. PARTNERSHIP BLVD, SPRINGFIELD, MISSOURI 65803-8877 P-417.831.9362 800.641.4282 F-800.743.5724 www.dmp.com XR550 and 263H HSPA+ Shown with X130 and 263C COMA Shown with 383 383 Rubberduck Antenna. Rubberduck Antenna. (Not to scaLe) SECURffy SIGNALING FDNY LISTED ISTED Your Source for Cellular Solutions The switch is on to cellular for many reasons. In isolated locations, cellular may be the best primary communications path option. Where land lines could go down, cellular provides a reliable backup path. In critical installations where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need, DMP has the technology to create reliable panel-to-central station digital cellular communications. Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station Uses digital cellular CDMA or HSPA+ data networks in the US and Canada Transmits email and SMS status messages to multiple recipients DIGITAL CELLULAR COMMUNICATORS CDMA & HSPA+ SYSTEM FEATURES Modular add-on to XI or XR Series Panels Check signal strength indication at the keypad Plug-and-play installation and activation of add-on MyAccessTM Messaging features, including text message communication modules alerts from the panel, and ability to send commands to the Power from panel or separate power supply, with low panel via text messages current draw for long standby battery life Supports the DMP App Fully supervised to ensure the health of communication XR500E/XR550E provides privacy for your data with DMP DMP Adaptive TechnologyTM switches communication paths encryption technology white maintaining supervision if the current path becomes XR1 00FC/XR500FC and 463C have FDNY approval for network unavailable on the XR SeriesTM panels or cell primary communication Direct reporting to any DMP Central Station receiver with no relaying or intermediary retransmission of alarm signals Can be equipped with Local or remote antenna PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 263C/263H/463C can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or, use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut orcompromised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones. Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The checkin frequency and programming for a backup path adapt to the checkin programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the CDMA or HSPA+ wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP Central Station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Cellular Service from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel. via an expansion card, the unit is ready to use the SecureCom service. After installing the panel or card, activate the unit via Remote LinkTM. After programming the panel. Remote Link recommends the optimum data plan based on the level of security, desired communication path configuration, and specific programming for the account. REMOTE CONTROL VIA MY ACCESSTM: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems, including the ability to arm /disarm, control outputs, retrieve system status, and perform automation functions. Each command received by the panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. REMOTE CONTROL VIA DMP APP The App provides Apple© iPhone and iPad owners, as well as Android users, with the ability to access a number of system functions remotely via cellular connection. As a dealer, the App provides the opportunity to load a company logo into the App. For both residential and commercial system owners, the attractive interface provides fast, easy access to the most commonly used system functions. APP CAPABILITIES At a glance, check system status including programmed areas. 'Arm or disarm the system in an instant Select from the Home/Sleep/Away arming options for home systems. Select from the All/Perimeter arming options for office systems Select from Area Arming Options Tap any programmed outputs to turn them on or off. Adjust lighting/thermostat/locks Video capability - up to six cameras, remote viewing. XTL SERIES The XTLC (CDMA) is available with on-board cellular which allows for MyAccessTM Messaging Email/SMS message commands to be sent directly to the panel. It is also available with on-board network or WiFi allowing for mobile App Control. This powerful burglary, residential fire, and door access panel provides cellular communication with built-in two-way wireless. - =- - - -=- _ -4-- - - MEMNON 01 Hiff I I Q 263C/263H DIGITAL CELLULAR COMMUNICATOR For existing XI & XR1 50 I XR350 I XR550 Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263C/263H allows alarm messages to be communicated to an SCS- 1 R or SCS-VR Receiver over their respective CDMA or HSPA+ networks. It provides a fully supervised alarm communication path over the network. The 263C/263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or battery back-up is needed*. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263C does not include a SIM card and is activated with the MElD number. All modules are ready for activation with SecureCom Wireless. 463C DIGITAL CELLULAR COMMUNICATOR XR1 00/XR500 Series panel users can plug in the 463C expansion card to quickly and easily incorporate cellular communications. In the panel enclosure, it requires no additional enclosures, power supplies, batteries, cabling or conduit connections -simplicity available only from DMP. It can be equipped with local antenna that attaches to the panel, or where necessary for improved signal strength a remote SMA antenna can be used, offering more installation flexibility. The 463C draws half the current of other comparable units. With the long standby battery life of the system batteries, the 463C can continue to provide a communications link for up to 80 hours during a power failure with appropriate standby batteries. The 463C does not include a SIM card and is activated with the MElD number using SecureCom Wireless. 464-263H/464-263C DIGITA— CELLULAR COMMUNICATOR The 464-263H or462-263C cellular modules can be plugged onto the XR1 00IXR500 panel boards to add cellular communications inside the panel enclosure. It requires no additional enclosures, power supplies, batteries, cabling or conduit connections. They can be equipped with a local or remote antenna. *A381 cable is required for the XRI50 IXR350 I XR550 Series. The XR500FC Series Fire panels used with the 463C Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path, the 463C provides the security of a communication link that continues to function, even when land lines are cut or compromised. This interface works on the CDMA data networks over a variety of carriers in the USA. TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in CDMA 263C/263H 463C 464-263C/464-263H XI30/XT5O X XR1 00 Series X X XR500 Series X X XTL Series X XR150 I XR350 I XR550 Series X 263C/263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (263C) Standby 13mA Alarm 13mA Current Draw (263H) Standby 24mA Alarm 28mA 463C SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 22mA Alarm 22mA 464-263C/464-263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw Standby 15mA Alarm (Nominal) 48mA Peak (-150mS) 85mA 263C/263H COMPATIBILITY XT Version 112 or higher & XR1 50 I XR350 I XR550 Series Panels (A 381 cable is required for the XR150 I XR350 I XR550 Series) 463C COMPATIBILITY DMP XR1 OOIXR500 Series panels using Software Version 202 or higher 464-263C/464-263H COMPATIBILITY DMPXR100/XR500 Series panels using Software Version 212 or higher ACCESSORIES 381-2 18 Coax Extension 381-12 12 Coax Extension 381-25 25 Coax Extension 383 Rubber Duck Antenna 386 Wall Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket 387-2 2dB Attack Enclosure Antenna 387-3 3dB MEG Antenna 387-4 4 SMA to N Extension Cable 387-8 8 SMA to N Extension Cable 387-25 SMA TO N CABLE, 25FT LM R1 95 387-50 SMATO N CABLE. 50F1 LMR195 ORDERING INFORMATION 263C CDMA Cellular Communicator (Verizon) 263C/381-2 CDMA Cellular Communicator w/ 381-2 Cable (Verizon) 463C CDMA Cellular Communicator (Verizon) 263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (263HCAN - Rogers)) 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T. T-Mobile. (263HCAN - Rogers)) 464-263C COMA Cellular Communicator (Verizon) 464-263H HSPA+ Cellular Communicator (AT&T. T-Mobile. (464-263HCAN - Rogers)) LISTINGS AND APPROVALS 263C/263H/463C California State Fire Marshal (CSFM) 263C/463C/464-263C FCC ID: MIVCNNO301 Industry Canada: 4160ACNN0301 263C/463C/464-263C Verizon Certified 263H PTCRB Certified (AT&T) 263H/464-263H FCC ID: RI7HE91ONA Industry Canada: 5131AHE91ONA 463C New York City (FDNY COA #6123 & #6145) Underwriters Laboratories (UL) Listed 263C/263H ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarms Units and Systems Accessory ANSI/UL 985 Household Fire Warning ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglary ANSI/UL 1635 Digital Burglar ANSI/UL 86.4 Fire-Protective Signaling 9th Edition (XR1 50 I XR350 I XR550 Series Panels only) 463C ANSI/UL 365 Police Station Connect Burglar Alarm Systems ANSI/UL 985 Household Fire Warning System Units ANSI/UL 1023 Household Burglar Alarm System Units ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units ANSI/UL 864 Control Units for Fire-Protective Signaling Systems 464-263C/464-263H ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems ANSI/UL 1610 Central Station Burglar Alarm Units Underwriters Laboratories Canada (ULC) Listed 263H (XR150 I XR350 I XR550 Series Panels only) ULC S304-06 Central Station Burglar ULC Subject-Cl 023 Household Burglar ULC/ORD-Cl 076 Proprietary Burglar ULC S545 Household Fire ULC S559-04 Equipment for Fire Receiving Centers and Systems 464-263H ULC/ORD-C1076 Proprietary Burglar ULC 5304-06 Central Station Burglar (II) 0 06O 0 @IEtw 2500 North Partnership Boulevard Designed. Engineered & Assembled Springfield. Missouri 658M-8877 I in Springfield. Missouri .'mpIe Expansion lutions 11 SEURIIY SiGNAliNG LISTED "V Expand your DMP Command Processorlm panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, glassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 moduels. - _1V_ 14 I / ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT ......- 1 ZONE EXPANSION MODULE FEATURES Provides Class B zones for burglary and fire • Easy connection to 4-wire keypad or LX-Bus' Compatible with DMP Command Processor Panels that allow • Proven design ensures stability and performance zone expansion . . . • Data LED on zone expander indicates good panel Suitable for mouiiting near protection devices 7 communication Connect devices using 4-wire bus • Durable and attractive plastic or metal housing Easily mount attrktive cases on wall or 3 gang box • Low current draws Compatible with all panel zone types • Can be powered from panel or auxiliary power supply 1 flIlE USE ON THE DMP LX-BUSTM 708 BUS EXTENDER MODULES 710 The modules can be used on the LX-Bus The 708 Bus Extender Modules allow you As a splitter, the 710 provides superior of DMP Command Processor Panels. The to increase the length of wire used to run mechanical wire connecting capability for modules connect to the 4-wire bus and an LX-Bus or keypad bus by a maximum of up to three additional 12 VDC LX-Bus or use only one zone address. To assign an 4,000 feet, while providing immunity to keypad bus circuits. This makes the 710 additional zone expander use the next noise on the wires. The 708 Bus Extenders module an excellent junction box when available zone address. are received from the factory as a pair of terminating multiple LX-Bus/keypad bus modules that connect between the panel runs at one location. As a repeater, the CONNECT TO KEYPAD BUS and LX-Bus or keypad bus devices. 710 module can be installed at the end of You can also use the modules as an addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, 715-16, and 725 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the cover snaps on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708, 710, 710F, and 725 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including Arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1 R Receivers. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710/71 OF BUS SPLITTER! REPEATER MODULES The 710 and 710F Bus Splitter/Repeater Modules allow you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710/710F Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! dli LADUS UI I'eypdU bus LIILUIL LU dUUW an additional circuit to be added, thus increasing the total wire length. 71 OF As well as providing all of the functions of the 710 listed above, the 710F also allows you to use the 725 Zone Expander to expand the number of 24 VDC zones. The 710F Bus Splitter/Repeater allows the connection of a 24 VDC power supply to the 725 to power smoke detectors and isolate the 24 Volt source from the panel. Therefore, the 710F must be used when using the 725 Zone Expander. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, gtassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP Command Processor panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included S IP CE ( S 0-0 CE CE M- 714171 S ZONE EXPANDERS 714-8,714-16,715-8, AND 725 24 VDC EXPANSION The 714 contains four Class B burglary 715-16 DESCRIPTION MODULE zones and is suitable for use with burglary The expanders are housed in a Model The 725 provides four 24 VDC powered and fire devices that are normally opened 340 locking metal enclosure suitable zones that enable you to connect or normally closed. Individual zones are for mounting in a remote location. 2-wire smoke detectors to the XR500 supervised with 1k Ohm EOL resistors and Each expander provides screw terminal Series, XR2500F, XR200, and XR200-485 can be programmed with any burglary or strips for zone inputs and data bus Command Processor Panels. As a result, fire zone type. connections, a two position jumper to the 725 provides you the flexibility to The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered Ohm EOL resistor and can be programmed with any burglary or fire zone type. fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k designate connection to the Keypad bus retrofit a 24 Volt system without the need or the LX-Bus, and an LED to indicate to run more wire or change to 12 Volt communication with the panel. Separate smoke detectors. zone End-of-Line resistors are included M1 with each expander. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 720T Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 720T. 7141715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8/714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8/715-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. 714-8,714-16,71 5-8, AND 715-16 FEATURES 8 or 16 protection zones per expander Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14 to 22 gauge wire for easy connection Suitable for mounting in a remote location 725 FEATURES Provides four 24 VDC zones Sensor reset performed through panel relay or 716 Output Expander Powered from 24 VDC power supply Supervised operation 24 Volt surge protection from 710F Provides ability to use 24 VDC 2-wire smoke detectors Easily mounted in 3-hole pattern ill DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. 711 FEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing 11111111k.- Digital Monitoring Product; ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-Hole Plastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC All DMP 12 VDC 710 N/A N/A Yes Yes 12 VDC 710F N/A N/A Yes Yes 712-8 Dip Switch 8 Yes No 12 VDC XT Series, XR100/XR500 Series, XR2500F 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure 725 Rotary 4 24 VDC Class B No Yes 24 VDC XR500 Series, XR2500F 7141715 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714 Average 7mA + 1.6mA per zone Alarm 7mA + 2mA per zone 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke 4 Alarm 7mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Dimensions 4.5" X 2.75" X 1.75" MODULE SPECIFICATIONS 708 SPECIFICATIONS (NONEUL) Operating Voltage 8.8 to 15.0 VDC Operating Current ,20mA Per Pair Dimensions 4.5" X 2.75" X1.75" Maximum Distance 4,000 feet between the two 1_708 M6dules 7I0171 OF SPECIFICATIONS Operating VoLtage ",'8.8 to 15 0 VDC Operating Current 710 30mA 71OF 40mA Dimensions 4.5" X 2.75" X 1.75" Distance .2,500 feet (onérnoduLe), 15,000 feet maximum, 711 SPECIFICATIONS Operating Voltage 8.8 toi5.0 VD 4' Operating Current Average 1 1m +; .1 per active zone Alarm 11mA+ 2mA per zone in alarm . Zone Voltage, 5 VDC (1.6mA across EOL) Dimensions 4 5" X 2 75" X i'.175"- .712-8 712-8 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC-- Current Draw 1 7m +1.6mAer active zone'. 17mA +2mA per zone in alarm Dimensions ' E4 5" H x 2 5" W 725 SPECIFICATIONS Operating Voltage 24 VDC Nominal' Average Current 8mA + 4mA per active zone Alarm Current 8mA +4mA peractive zone I. +30mAper smókein alarm J, + 47mA per shorted device EOL Resistor Model 316 6.8k EOL - -- -- 714-8, 714-16, 715-8, AND 715-16 SPECIFICATIONS Operating Voltage 8.8 to 15.0 VDC Operating Current 714-8/16 Average 20mA+ 1.6mA per zone Alarm 20mA + 2mA per zone 715-8/16 Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Alarm 20mA + 58mA per shorted zone + 0.1 per 2-wire smoke + 30mA per smoke in alarm Enclosure 20-Gauge cold-rolled steel Dimensions 12.5" W x 11.5" H x 3.5" D 714-8/-16 Color Gray 715-8/-16 Color Red LISTINGS AND APPROVALS Refer to the appropriate panel programming and installation guide for specific compliance listings for installation and programming requirements necessary to meet a particular approval. Underwriters Laboratories (UL) Listed California State Fire Marshall (CSFM) New York City MEA accepted (711, 714, 715 only) For additional information, access www.dmp.com and select Compliance. ____ LLAJ-'t.J1 a lPtlli 0 0• Ij 2500 North Partnership Boulevard Digital Monitoring P,'od,,oeo L11k 1B (X Springfield, Missouri 65803-8877 System Sensor's i"series smoke detectors repres significant advancement in conventional detecti The j3 family is founded on three principles: instal, Photoelectric Smoke Detectors SYSTEM SENSOR ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings MEAMSFM LISTED APPROVED approved approved S911 3011446 7272-1209:210 290-01-0 2093 Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire the bases included with the heads.The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, il heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms. Two-wire il detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent per-foot-obscuration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on two-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Smoke Detector Specifications Smoke detector shall be a System Sensor j3 Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2VVT-B, 4W1-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2W1-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. ved Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 uA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-1 20°F (0°C-49°C); 2WT-B and 4W1-B: 32°F-i 00°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble 2W1-B and 4VVT-B only: 41°F (5°C) Sensitivity 2.51/o/ft. nominal InputTerminals 14-22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up . Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information ?Model Thermal 2W-8 No Wiring, 2-wire Alarm urrent"', 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA © 24V 4VV7-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter SYSTEM 02 6SystemSensor. 3825 Ohio Avenue. St. Charles, IL 60174 current product information, including the latest wmion of this data sheeL Phone: 800-SENSOR2 . Fax: 630-377-6495 IEWA CUSTOM DOCUMENT ENCLOSURE SYSTEMIEC Modified Mier BW-1 06R for Bay Alarm 12"W x 12"H x 4"D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom Tth1 RECaRO T c Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling or emailing Mier Products,lnc. - - 800-473-0213 1 info@mierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 Email: tshelton@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 263H: Cellular Communicator *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver 1100R: Wireless Repeater 1103: Wireless Transmitter 1135: Wireless Siren *Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. Rev 04-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-13 and 4W1-B employ a thermistor type heat sensor (135F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 -35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division