HomeMy WebLinkAbout2234 RUTHERFORD RD; ; AS070006; Permit5/16/25, 3:33 PM AS070006 Permit Data City of Carlsbad Sprinkler Permit 2234 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2120612600 Lot #: 0 Permit No: AS070006 Status: PENDING Applied 1/16/2007 Approved: Reference No.: Issued: PC #: Inspector: Project Title: 24 HOUR FITNESS PRE-ACTION SYSTEM INSPECTIONS 3 @ $62/EA Applicant: FACILITIES PROTECTION SYSTEMS SUITE D 1150 W.CENTRALAV BREA, CA Owner: RUTHERFORD ROAD LLC C/O STONERIDGE CAPITAL PARTNERS 4350 VON KARMAN AVE #400 NEWPORT BEACH CA Fees ($)IAdd'IFees($) Total(s) Balance ($) 186 0 186 0 about:blank 1/1 PRE-ACTION DETECTION AND CONTROLS ENGINEERING SUBMITTAL 24 HR FITNESS 2234 RUTHERFORD RD. CARLSBAD, CA ED Ik BITTED APPROVED CARLSBAD FE DEPARTMENT 08-24-06 PROVIDED BY: r• Ci FACILITIES PROTECTION S YSTEMS 1150 W. CENTRAL AVE. SUITE 'D" BREA, CA 92821 TEL: 714-257-2244 FAX: 714-257-2240 C.L.#592289-CIO/C16 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0900:137 Page 1 of 2 CATEGORY: Control Unit (Non High-Rise) LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64015 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Model CyberCat 1016 or 254 control unit, part no. 10-064-c-p-d or 10-066-c-p-d (C: R=Red or B=Black; p: 1120V or 2240V; d: B=Blank or L=Lexan) fully addressable *fire alarm control panel. Base configuration includes the main board, enclosure and a transformer. *Suitable for critical process management and voice evacuation via Fike Guard model FGX- MP/DP. *Model Cheetah Xi 10-068 Fire Suppression Control Unit. Local, auxiliary, remote and central station service. *Model Cheetah Xi also suitable for releasing service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 10-2472,-2525,-2542 Controllers 10-2473 Supplemental Loop Module 10-2474 Supplemental Power Supply 10-2204 CRM4 Relay Module 10-2254 Reverse Polarity Module *10..1832 Agent Releasing Module III *102482 Network Card FGX-MP/DP Voice Evacuation System *24..001 thru 24-012 Master Panel Voice Evacuation System *24-013 thru 24-024 Distribution Panel Voice Evacuation System *10-2541 C Enclosure *102541CL Enclosure with Lexan 10-2483-C or -C-L Enclosures 10-2476 DACT 10-2321 Remote Display *1011x LED Display Graphic 10-2413 Masterbox Supervision Module 10-2361 Series Impedence 10-2373 Zone Annunciator *55..052 -053 Releasing Module *55042 Control Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. *rev 10-07-2005 jew Listing No. 7165-0900:137 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *rev 10-07-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or + recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager FIKE CHEETAH XITM INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike's Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-to- peer modular suppression control system. It is ideal for all life safety and property protection applications, and is intended for both commercial and industrial use. It is designed with extensive programmability that allows the almost-instantaneous relay of information and the ability to perform process management tasks with ease including shutdowns, HVAC, Voice Evacuation Systems, Dampers, Doors, Elevators, and Security, CCTV/Building Management Awareness. This cost-effective panel comes standard with two Signaling Line Circuits (SLC) that support 254 devices each. This is expandable to four loops and a total panel capacity of 1016 devices, with any mix and match of sensors and modules. The Cheetah Xi utilizes extreme intelligence via its Eclipse based sensors including photoelectric, photoelectric with heat, ionization, photoelectric duct, and heat detectors. It also utilizes Eclipse based modules such as the monitor, mini- monitor, relay, intelligent pull station, releasing and control modules. With Cheetah Xi, every device communicates as a peer on the signaling line circuit. These peers not only communicate up-to-the-second information to the control panel, but also communicate with each other. Each device is capable of generating accurate and highly detailed information. Conventional suppression alarm systems give a general idea of the fire's location, while the Cheetah Xi's intelligent sensors indicate precisely which device is in an alarm state. This intelligence provides incredible speed with response times as little as one-quarter second between manual pull station and notification appliance. It's flexibility allows you to attach the intelligent devices that are required for your specific application. The System is programmed with either the Windows based field configuration software CLINXM or through a comprehensive password protected front-panel keypad programming option. This option allows you to quickly update and adapt to any future requirements or changes in the system such as changes in occupancy or remodeling. The sophisticated control panel circuitry coupled with the software allows you to read specific information and sensitivity levels of the different eclipse devices. The sensors also compensate for any changes due to age, contamination, or other environmental factors. System Operation The Cheetah Xi Control system operates on a "Zone and State" relationship. In this design, all input and output devices must be assigned to at least one zone or to all zones (254 are available), each one defining an area to be protected. Input devices can be assigned up to four zones (one zone is typical) and output devices may be configured for up to 254 zones. These devices use the SLC signaling line circuits to exchange status information with other devices as well as with the control panel. When an input is activated, it is configured to cause its associated zone to enter into an operational state. Any detection device will cause the associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone. This system is completely modular, allowing you the flexibility to design a system that is just right for your application. A typical configuration is shown on page 2 that illustrates the communications of a Cheetah Xi system. I. Fike Cheetah Xi APPROVALS UL S2203 FM 3023436 Form No. D.1.10.O1 I 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 . () 229-4615 www.fike.com DESCRIPTION (Cont) Vt5DA L,rPIu$ > Photo Detcclor NAC Module I tI. iIdhi muWfft state; c epttatico I P .I v. flt.kty Module Releasing Module Pnkrrns Prncs; Manurrnet TaI. Suet, 4 COISIISIITh Onus Attest Srntt5t-.,n. %W t n. c Art -Gaseous Clean Agents STANDARD FEATURES/SPECIFICATIONS The Cheetah Xi features are designed to save lives and protect your valuable capital investments through unprecedented speed, intelligence and flexibility. These features include: General Two 24VDC, 2A N.AC (bell) circuits on main board with built in System Sensor or Gentex synchronization protocol 254 user defined zones 80 character, backlit LCD display Real time clock 3200 event history buffer Critical process monitoring Oneperson Walktest capability Disable by zone Drill function at panel and remote Provides solenoid releasing operation Alarm verification Easy to add/remove devices Diagnostic menus Removable terminal blocks for field wiring Local piezo with distinct event tones 10 Status LEDs to easily identify system status Optional point ID DACT Module available Supports up to 31 peripheral devices such as Remote Display, LED Graphic and Zone Annunciators Page 2 1! Page 3 STANDARD FEATURES/SPECIFICATIONS (Cont.) Power 6 amps useable alarm power, expandable to 12 amps (2 A standby/expandable to 4 Operation from I20VAC/60 Hz or 240 VAC/50 Hz Two 24V DC, 2A continuous auxiliary power outputs (Expandable to 5 circuits with SPS) One 24V DC, 2A resettable auxiliary power output Supports up to 75AH of batteries, expandable to 150 AH using SPS Signaling Line Circuit Address devices with Infrared (IIR) tool, similar to remote control device Two SLC loops, expandable to four, NFPA style 4 or 6 254 devices per loop, system maximum 1016 devices with SLM (Supplemental Loop Module) True peer-to-peer digital protocol for extremely fast and reliable communications Auto-learn function Automatic day/night sensitivity adjustment Automatic holiday sensitivity adjustment Acclimate operation for sensors IR Tool provides ability to read sensitivity levels or perform remote test of device Devices contain multi-color LED for quick reference of device status Sensors provide early warning pre-alarm detection and can also provide a summing feature. (up to eight sensors) NAC Circuit Two NAC circuits standard Rated at 24VDC, 2.0 Amps maximum Built-in synch protocol for both System Sensor and Gentex devices CONTROL SYSTEM MODULES Cheetah Xi Controller (P/N 10-2542) The Controller contains the power supply, microprocessor, hardware interface, display and keypad. The controller's internal power supply provides 2 Amps Normal Standby Current/6 Amps Alarm Current. Comes standard with two signaling line circuits (SLCs). Enclosure Steel Enclosure 21.10" H x 14.35" W x 4" D (Back-box dimensions) Enclosure is equipped with a 0.50" wide lip to facilitate flush mounting Removable door for ease of installation Two door options available; with or without lexan cover on oval opening Available in red or grey Dead Front option available Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 10-2528) The DACT provides interface with Central Station monitoring systems. It is available with 5 contact zones of connection OR the intelligent serial interface which provides point ID information. The Contact ID form is the preferred reporting format. It provides a four digit account code followed by a three digit event code, a two-digit group number, and a three digit contact number, all of which are used to provide specific point identification. This DACT can also provide an SL& or 4/2 Pulse reporting format.. Note: 10-2476 is the same as 10-2528 with enclosure for external mounting. 40, 1,11 tt CONTROL SYSTEM MODULES (Cont.) Supplemental Power Supply (SPS) (P/N 10-2474-P) The 10-2474-p includes the power supply circuit board and transformer (-1 for I20VAC primary; -2 for 240VAC primary). This module adds up to 2.OA external standby power and 6.0A alarm power (4 A standby/12A alarm total). AC power and standby batteries are supervised. Supports charging up to 75Ah of additional standby battery. Charging may be turned off in configuration if batteries are not required on SPS. Dimensions: 4-1/2 Lx 5-1/2" H x 2" D. Weight: 0.66 lbs. Supplemental Loop Module (SLM), (P/N 10-2473) The SLM adds two more SLC loops. Loop specifications and wiring for SLM are the same as the main controller. It interfaces to the main Control Panel using four standoffs supplied with the SLM. Dimensions: 2" L x 6-1/2" H x 1" D. Weight:: 0.12lbs. Fike Relay Module (P/N 10-2204) The CR1\14 provides 4 additional independently programmed relays. Cheetah Xi Control Panel supports up to 2 CRM4 modules if either options are not unused) on the main controller board. Each relay may be wired across normally open or normally closed contacts. Dimensions: 3-1/2" Lx 1-1/2" H x 2" D. Weight:: 0.10 lbs. Fike Reverse Polarity Module (CRPM) (P/N 10-2254) The reverse polarity module provides the ability for UL Remote Station supervision. This supervision is typically performed with a direct, leased line connection. It interfaces to the main control board using four standoffs supplied with the RPM. Dimensions: 3-1/2" L x 1-1/2" H x 2" D.. Weight: 0.08 lbs.. Fike Remote LCD Display (P/N 10-2321) This module provides information about the host Cheetah Xi System in a remote location. It receives the intelligent data stream from the RS485 output of the Cheetah Xi. The remote display provides the capability to remotely reset, silence, and acknowledge the main control panel. Security to the unit is available via the standard Fike key. It mounts to a 5 gang masonry box Raco 694). The unit can be surface or flush mounted. Dimensions: 9-7/32" L x 3-3/4" H x 2-1/2" D. Weight: 2 lbs. Fike Zone Annunciator (P/N 10-2373) The Zone Annunciator provides instant visual status of up to 10 zones of fire protection. Each zone has a red Alarm LED and yellow Trouble/Supervisory LED. Each LED is individually programmable for zone(s) and state(s). Each LED can be labeled using Avery Label 6467 or 5418. The annunciator also has an internal piezo to provide instant audible notification of status change. It is intended to be powered via the Cheetah Xi panel 24VDC auxiliary power. It communicates with the main control panel via R5485 communication. The annunciator provides the capability to remotely reset, silence and acknowledge the main control panel. Security to the unit is available via the standard Fike key. It mounts to a 5 gang masonary box (Raco 694). The unit can then be surface or flush mounted. r - - - -- .--. L L I1JH ' Q-1 - Page 4 Fike Network Module (P/N 10-2482) The Network Module provides the ability to network up to 128 control panels. This typically _-... . .-. would consist of other Cheetah Xi panels or CyberCat fire alarm panels. The Cheetah Xi network uses a "common zone" functionality. Zones 1-254 are common to all panels on the network and any input will cause activation of all outputs for the same zone, regardless of r . which panel the devices are connected to. Regardless of zone number, every state (alarm, . trouble etc.) that occurs is displayed by all panels on the network. The Cheetah Xi network is peer-to-peer which allows each panel to operate independently in the event that the network- wires are damaged. CONTROL SYSTEM MODULES (Cont.) The following system modules are available for the CyberCat Control System: Part Number Description 10-068-c-p-i Cheetah Xi System-Includes Controller, Enclosure, and Transformer c:(R=Red, G=Grey) p:(1=120V 2240\7) 1= with lexan 10-2542 Cheetah Xi System Controller (included with 10-064-c-p-d) 10-2528 DACT, 5 zone with Serial interface 10-2474-p SPS - Supplemental Power Supply p: (1= 120V 2=240V0 10-2473 SLM - Supplemental Loop Module (adds 2 loops; 254 devices ea.) 10-2204 CRM4 - Relay Module 10-2254 CRPM - Reverse Polarity Module 10-2321 FIKE Remote Display 10-2373 Zone Annunciator 10-2482 Network Module lO-lix LED Graphic 10-2519-c Dead Front Option c: ERRed, GGrey CHEETAH XI/PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-LINX software. This software provides the designer the capability to provide a pre-engineered design. The user can review the construction plans to assign the zones. The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. -__ Page 5 JR Configuration Tool - This optional hand-held infrared remote control is available on the Cheetah Xi system. This small device can be used in the field to simplify installation, testing and service. It operates with 2 AA batteries and can read device information such as loop, address, branch and service dates and initiate device test. This tool: Communicates bi-directionally with any Cheetah Xi device Easily addresses devices by setting the loop and address Quickly reads sensitivity levels, date serviced, device type, loop and address, manufacture date Immediately records the date serviced Instantly initiates walk test of any sensor or module Accesses and tests hard-to-reach sensor or module (such as duct detector) through any other device on loop Field Wiring Although the installation instructions provided for each module should be used for installation, please see the a general wiring diagram on the following page. Wiring Specifications Maximum Resistance: 70 ohms Maximum Capacitance: .06 uf 12,000 ft. maximum distance total from panel to last device. Field Wiring Diagram 10.2516 10.111 I °' - POWER LIMITED AND SUPERVISED r FIRE GUARD OPTIONAL OACT R 22-1. 10-2528 OPTIONAL CRM4 OPTIONAL RELAY CRM4 OR CRP 50.2204/10-2254 0100 0.41 6401 100600 0.60 ERD ©--- C7, 14 1600 I 0I04100 40 0 K Fik POWER LIMF1EO 24000 AUXILIARY 0010000,25 1106. 0016 10.2473 (1016 ONLY) SffLE 5010055.00.62510. tt J-E 06060 C/BE ROUT 0.0 The following parts are used for configuration, testing and diagnostics of the CyberCat: Part Number Description 55-051 Infrared (IR) Remote Control Tool for Programming/Testing Devices 06-327 C-linx Software 10-1874A Interface Cable for C-linx Software (DB9 to RJI 1) 10-2477 DACT Programmer Page 6 CHEETAH XI INTELLIGENT DEVICES Photoelectric Smoke Sensor (P/N 63-1052/63-1058) The photo sensor provides peer-to-peer digital protocol for reliable, fast communications The sensor includes a tn color LED for instant indication of device status. An acclimate feature is defaulted ON to provide optimum fire detection response This feature allows sensors to respond to a particular environment and its operating parameters are maintained within non-volatile RAM _____ in the sensor. Dual Alarms (night and day sensitivity) with threshold settings between 1.3 3 6D/oft Dual Pre Alarms with threshold setting between 0.5 4 0%ft Photo/Heat Combination Sensor (P/N 63-1053/63/1059) The photo/heat sensor provides peer-to-peer digital protocol for reliable fast communications The sensor has the ability to alarm from either or both different types of detection and includes a tri-color LED for instant indication of device status Dual electronic thermistors add 13° F fixed temperature thermal sensing to the standard photoelectronic sensor. Even though this is a dual sensing device, it only uses one address on the SLC loop Thermal Sensor (P/N 60-1039/60-1040) The thermal sensor provides peer-to-peer digital protocol for reliable fast communications. The sensor includes a tn-color LED for instant indication of device status. The spot-type heater sensor is designed to be programmable for a set- point range of 135° F to 174° F for ordinary detection or 175° F to 190° F for intermediate detection. Detectors in the ordinary range may be programmed for either fixed temperature or 150 F rate of rise operation. The detection set-point is software programmable in single degree increments from 135° F to 190° F. Sensor Base (P/N 63-1054/63-1060 6" and P/N 63-1055/63-10614") . . The 6" sensor base will mount directly to 3-1/2 " and 4' octagon boxes, . f 4" square boxes (with or without plaster rings) and single gang boxes. The base is approximately 2 inches larger than the sensor, providing a , contouring effect and covering the junction box. It is used with any of the Cheetah Xi sensors, Fully programmable LED feature also available. ' •• Ion Sensors (P/N 67-033/67-034) Ion Sensors provide peer-to-peer digital protocol for reliable, fast communications. The sensor includes a tri-color LED for instant indication of device status. An acclimate feature is defaulted ON to provide optimum fire detection response. Dual alarms (day and night sensitivity) with threshold settings between 80-50 uAmps MIC are available. Dual pre-alarms with threshold settings between 100-40 umps MIC are also available. Configurable for acclimate, alarm verfication, and drift compensation. INTELLIGENT MODULES Fike's intelligent modules provide a fire alarm dry contact device directly connected to the Cheetah Xi intelligent loop. Each module may be assigned to a single zone or up to four zones. Any number of UL listed contact closure devices may be used. Mini-Monitor Module (55-045/55-050) 2-3/4" x 1-3/4" miniature module for mounting in the small junction box behind a monitoring device. This device will monitor a Class B wired input device using the 39K ohm end of the line resistor. Short circuit detection feature also available. 4 - 4 Page 7 4" Square Monitor Module (55-041/55-046) Mounted with cover plate on a 4" square junction box. This device will monitor a Class B or Class A wired input device. Class B wiring requires a 39K ohm end of line resistor.. Short circuit feature also available. Pull Station Monitor Module (P/N 20-1063/20-1064) r......... The intelligent pull station has all of the same addressable input module electronics inside the pull station for one complete addressable pull station. Activation is accomplished by pushing In and pulling down as instructed. A hardware key is issued to reset the device. L. Supervised Control Module (P/N 55-042/55-047) The Supervised Control Module (SCM) provides building notification appliance circuits (NAC), n intelligent interface to the Cheetah Xi Intelligent loop. It also has the capability of operating solenoids rated up to 2 amps @ 24VDC. Mounts in a 4" x 4" x 2-1/8" junction box. Relay Module (P/N 55-043/55-048) The Relay Module provides building dry contact output interface via the intelligent loop. Two configurable (single operation) relay Form C contacts rated for 2 Amps @ 30VDC, 0.5a @ 120VAC. Wide range of operating modes including multi-zone operation, up to 4 different states and multi-state programming Operating parameters are maintained in non- volatile RAM for quick and reliable response to emergency conditions. This module mounts on a 4" x 4" a 2-1/8" junction box. Releasing Module (P/N 55-052/55-053) Releasing Modules is designed to provide reliable operation of a solenoid or Agent Release Module ARM) for clean agent, carbon dioxide and pre-action ptinkler/ deluge system actuation. Each releasing module is protected from inadvertent operation by an intelligent switch which requires transmission of a complicated code before activating the releasing output. This module is capable of providing up to 2,0 amps @ ...-, 24 VDC of output power for solenoid applications. The releasing module requires a separate 24 \TDC power source in addition to the SLC. Duct Sensor (Sensor is P/N 63-1057/63-1062; Housing is P/N 63-1056) Ti The Duct Housing contains a circuit board that provides connection to standard remote accessories and also provides a relay contact output that transfers upon activation of the DUCT detector. Four different lengths of sampling tube are available for duct penetration: Length Part Number 1.5' 02-3721 3.0' 02-3722 5.0' 02-3723 10.0' 02-3724 FONPORAOTION Copyright © Fike Corporation All Rights Reserved. Form No. D.1.10.01 July, 2005 Specifications are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:140 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 55-042 and 55-7 Supervised Control Moduletbd els 55-041 and 55-046 Monitor Module; Mod 1:15-043 and 55-048 Relay Models 55-041 and 55-046ule; 55-045 and 55-050 Mini- Monitor Module. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 15-30 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 73001653:180* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager INTELLIGENT MODULES DESCRIPTION The Eclipse protocol, manufactured by System Sensor, is a peer-to-peer, all digital protocol from that allows for numerous applications such as fire, security, access and HVAC control. Eclipse series intelligent modules provides faster device response time, with more flexibility than ever possible before. This digital, peer-to-peer protocol enables pinpoint accuracy in as little as a quarter second - without interference problems that can plague other systems. The Eclipse system distributes intelligence to the networked devices. In fact, Eclipse turns every networked device into a peer, capable of generating messages readable by the entire system. Additionally, with Eclipse, no special communication cables are required, making it ideal for retrofit applications. The isolator versions have on-board short circuit isolators to prevent shorts on the signaling line circuit (SLC) from disabling all devices on the intelligent loop. Eclipse monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterfiow switches, and more. Each module is rigorously designed and tested for electromagnetic compatibility and environmental reliability, in many cases exceeding industry standards. Full size modules mount in a standard 4" x 4" x 2 1/8" junction box. Wiring terminals are easily, accessible for troubleshooting purposes. Relay modules are to be designed for activating products connected to an alarm system and the mini monitor module can monitor the wiring to the device for open circuits via an end of line resistor. - Configuration JR Tool (55-051) 55-041/55-046 Monitor Modules are used to monitor the normally open contacts of an auxiliary device. In addition to monitoring the contact, the device will supervise the wiring to the device for open circuits via an end of line resistor This device is capable of class A or class B operation. Also capable of short circuit detection. The small size of the 55-045/55-050 Mini Monitor Module allows it to fit inside devices or junction boxes behind devices. Also capable of short circuit detection. 55-042/55-047 Control Modules are used to switch an external power supply or audio amplifier to notification appliances. The devices will supervise the wiring to the auxiliary device for open and short circuits via an end of line resistor. The control module will also have the capability to monitor the external power input for loss of power (DC voltage supplies only). This module is capable of Class A or Class B operation. 55-043/55-048 Relay Modules are designed for use in activation of products that are connected to an intelligent fire alarm system. It provides two sets of Form C contacts that switch together (one DPDT relay). There is also an input that is capable of monitoring a dry set of contacts for open or closed conditions. 55-052/55-053 Releasing Module are designed to provide reliable operation of a solenoid or Agent Release Module (ARM) for clean agent, carbon dioxide and pre-action sprinkler/ deluge system actuation. Each releasing module is protected from inadvertent operation by an intelligent switch, which requires transmission of a complex code before activating the releasing output. This module is capable of providing up to 2.0 amps @ 24 VDC of output power for solenoid applications. The releasing module requires a separate 24 VDC power source in addition to the SLC. 55-051 Configuration JR Tool is a remote control designed to communicate with Eclipse devices via infrared IR signals. The remote control will give the user the ability to communicate with the panel and other devices through any selected device on the loop. The 55-051 can read device information such as type, loop, and address along with set loop, address, branch and service date. It can also initiate a walk test and a device test. The 55-051 features a 16-character liquid crystal display and a 17-button keypad. Form No. P.1.53.01-1 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 (816) 229-0314 www.fike.com STANDARD FEATURES/SPECIFICATIONS Peer-to-Peer Communication Distributed intelligence Greater system design freedom Digital communication protocol Numerous applications (Fire, Security, Access and HVAC Control) Fast response time Superior noise immunity Low standby current Mounts to standard 4" junction box Wiring terminals easily accessible Communicate with the devices via hand-held configuration tool General Module Specifications Operating Voltage: 15-30VDC Alarm Current: 2.0 mA (red LED on) Temperature Range: 320 to 120°F (0° to 49°C) Relative Humidity: 10% to 93%: non-condensing Dimensions: - 55-045/55-050: 2.7W x 1.3"H x 0.6"D - Others: 4.26W x 4.2"H x 1.2"D Specifications: 55-042/55-047 Standby Current Avg.: 560 mA max. avg. (continuous broadcasts) External Power Supply: 9-80VDC(Normal Range); 0- 2VDC (Trouble Range) End-of-Line Resistance: 39 k ohms (included) Maximum VAC Circuit Wiring Resistance: 100 Ohms Standby Current: 500 mA max. avg. (continuous broadcasts) Dry Contact Short Circuit Current: 30 mA max. avg. Relay Contact Ratings: - 3.0 A @ 30VDC resistive non-coded - 2 A @ 30VDC resistive coded - 0.9 A @ 70.7VAC resistive non-coded - 0.7 A 70.7VAC inductive (PF=.35) non-coded Specifications: 55-051 Dimensions: 1.3"H x 2.2"W x 7.7"L Communication Range: Up to 30 feet Battery Life: 168 hours (typical usage) Operating Temperature Range: 320 to 1220F Relative Humidity: 10% to 90% RH non-condensing Specifications: 55-041/55-046 Standby Current: 485 mA max. (continuous broadcasts) IDC Voltage: 5.4\TDC max. VMaximum IDC Wiring Resistance: 100 ohms Specifications: 55-045/55-050 Standby Current: - 485 mA max. (continuous broadcasts) - 745 mA max. (continuous broadcasts IDC Shorted) JDC Voltage: 5.4VDC max. Wire Length: 6.5" Maximum IDC Wiring Resistance: 100 ohms AVAILABLE MODELS Description Fike Model No. Manf. Model No. Non-isolator Versions Monitor Module 55-041 EM-IM Relay Module 55-043 EM-111 Supervised Control Module 55-042 EM-1SR Mini Monitor Module 55-045 EM-IMM Releasing Module 55-052 EM-MM Isolator Versions Monitor Module 55-046 EM-IMi Relay Module 55-048 EM-1RI Supervised Control Module 55-047 EM-1SRI Mini Monitor Module 55-050 EM-IMMI Releasing Module 55-053 EM4RMI Accessories Control Module Barrier 20-1071 Surface Mount Box 20-1072 Configuration JR Tool 55-051 EA-CI' FIke Copyright © Fike Corporation All Rights Reserved. ORP OR A 110 N Form No. P.1.53.01-1 July, 2005 Specifications are subject to change without notice. INTELLIGENT GRAPHIC ANNUNCIATORS DESCRIPTION Fike Intelligent Graphic Annunciators are designed to be used with Fike's intelligent control panels such as the Cheetah, Cheetah Xi, and CyberCat systems. These annunciators provide a graphic display of the protected area using LED's to indicate the location of smoke detectors or other intelligent devices. LED's can be individually programmed to illuminate for selected individual addresses or zones for certain states such as alarm or trouble. These annunciator panels combine custom design with rugged construction. The display window is constructed of plexiglass over lexan and mounted in a steel door. The back-box is constructed of steel and houses all modules required for a custom designed panel. There are currently six basic sizes of enclosures available, each capable of being flush or surface mounted. Intelligent graphic annunciators can be ordered in the either gray or black. The lexan comes in white with black text. Optional background colors are also available. Panels: 10-121-X is 14" x 14" with a viewing window of 10" X 10" and accepts up to 64 LED's or annunciation points. 10-122-X is 24" x 24" with a viewing window of 20" X 20" and accepts up to 384 L.E.D.'s or annunciation points. 10-123H-X is 36" x 24" with viewing window of 32" X 20" and accepts up to 512 LED's or annunciation points. 10-123V-X is 24" x 36 with a viewing window of 20" X 32" and accepts up to 512 LED's or annunciation points. 10-124H-X is 36" x 30" with a viewing window of 32" X 26' and accepts up to 640 LED's or annunciation points. 10-124V-X is 30" x 36" with viewing window of 26" X 32" and accepts up to 640 LED's or annunciation points. * Other custom sizes are available. ** X = Black (B) or Gray (G) The number of LED's can vary depending on the graphical layout. Please contact Fike to determine the maximum L.E.D.'s for your customized application. Circuit Boards: 10-2411 Graphic Micro Controller Card (up to 256 LED's, compatible with Cheetah, CyberCat, or Cheetah Xi control systems. Up to 4 total can be installed per enclosure) 10-2086 Switch Card (Provides switches for lamp test, silence, etc.) 10-1858 L.E.D. Driver Card #1 (for use of up to the first 128 LED's connected to the micro control card) 10-1859 L.E.D. Driver Card #2 (for use of up to the second 128 L.E.D.'s connected to the micro control card) Cable Assemblies: 10-1903 Cable Assembly 24" Micro-Driver 10-1950 Cable Assembly 48" Micro-Driver 02-3029 Cable Assembly 24" Micro-Switch 02-3030 Cable Assembly 10" Micro-Switch FEATURES Internal switch for system reset, silence, graphic lamp test or system acknowledge L.E.D.'s are completely configurable through C-Linx software. Custom Design to accommodate, individual floor plans. Six Basic Sizes available in black and gray Surface or Flush Mounting with option trim ring Hinged Door Assembly With Keyed Lock Standard L.E.D. Colors: Amber, Red, Green, Yellow Multi-Color Background Available Efficient Installation Modular circuit board design for expandability Form No. P.1.83.01 I 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 (816) 229-4615 www.tike.com nJ) ORDERING INFORMATION Fike P/N Description Complete Door Assemblies 10-121-X Graphic Annunciator 14" x 14" w/ 10" x 10" viewing window 10-122-X Graphic Annunciator 24" x 24" wl 20" x 20" viewing window 10-123H-X Graphic Annunciator 36" x 24" w/ 32" x 20" viewing window 10-123V-X Graphic Annunciator 24" x 36" w/ 20" x 32" viewing window 10-124H-X Graphic Annunciator 36" x 30" w/ 32" x 26" viewing window 10-124V-X Graphic Annunciator 30" x 36" w/ 26" x 32" viewing window Replacement Door 10-2598-X Graphic Annunciator Door 14" x 14" w/ 10" x 10" viewing window 10-2599-X Graphic Annunciator Door 24" x 24" w/ 20" x 20" viewing window 10-2600H-X Graphic Annunciator Door 36" x 24" w/ 32" x 20" viewing window 10-2600V-X Graphic Annunciator Door 24" x 36" w/ 20" x 32" viewing window 10-2601H-X Graphic Annunciator Door 36" x 30" w/32" x 26" viewing window 10-2601V-X Graphic Annunciator Door 30" x 36" w/26" x 32" viewing window Backbox 10-2588 Backbox 14" x 14" for P/N 10-121-X 10-2589 Backbox 24" x 24" for P/N 10-122-X 10-2590H-X Backbox 36" x 24" for P/N 10-123H-X 10-2590V-X Backbox 24" x 36" for P/N 10-123V-X 10-2591H-X Backbox 36" x 30" for P/N 10-124H-X 10-2591V-X Backbox 30" x 36" for P/N 10-124V-X Miscellaneous 10-2411 Graphic Micro Controller Card 10-2086 Switch Card 10-1858 L.E.D. Driver Card #1 10-1859 LED. Driver Card #2 10-1903 Cable Assembly Micro-Driver 24" 10-1950 Cable Assembly Micro-Driver 48" 02-3029 Cable Assembly Micro-Switch 24" 02-3030 Cable Assembly Micro-Micro 10" 10-2611-X Trim Ring for 14" x 14" 10-2612-X Trim Ring for 24" x 24" 10-2613-X Trim Ring for 36" x 24" 10-2614-X Trim Ring for 36" x 30" L.E.D.'s 02-3009 Red LED 02-3038 Amber LED 02-3013 Green LED 02-3247 Yellow LED Notes: X = Black (B) or Gray (G). Complete door assemblies includes: one micro card, one driver card, one switch card, and appropriate cables. Backbox and LED's must be ordered separately. F1 ke Copyright © Fike Corporation All Rights Reserved. ORPORATtON Form No. P.1.83.01 January, 2006 Specifications are subiectto change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0900:139 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 63-1052, 63-1058, 63-1057, 63-1062, 63-1053 and 63-1059 photoelectric smoke detectors. Models 63-1053 and 63-1059 employ a 1350 fixed temperature electronic thermistor heat sensor for use only as a supplement to the smoke detector. This thermal circuitry is not approved for use in lieu of required heat detectors. Models 63-1052, -1058, -1053, -1059 are suitable for installation in a duct, velocity range 500-4000 fpm and open area protection, velocity range 0-4000 fpm. Models 63-1057 and 63-1062 are suitable for installation inside 63-1056 duct housing only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 V dc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF 72721653:181* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0900:141 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 60-1039 and 60-1040 combination fixed-temperature and rate-of-rise type heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION MARKING APPROVAL: XLF 21.6 V Fixed Temperature Rating: 135 - 155°F at 50 ft spacing 165-174°F atl5ftspacing 175- 190°F at 50 ft spacing In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical/temperature rating, and UL label. Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 72701653:179* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0900:138 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64013 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Models 63-1054, 63-1055, 63-1060, and 63-1061 detector bases. Each unit consists of resistors, capacitors, diodes, photo diodes and LED, mounted on a printed wiring board inside an enclosure which has an opening to the outside air. These devices are intended for installation on a vertical wall surface, ceiling or in a duct with a UL Listed Head. Refer to the listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible 63 Series smoke or heat detector heads and fire alarm control panels. Refer to listee's Installation Instruction Manual for details. XLF: 73001653:178* *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager INTELLIGENT LOW PROFILE PLUG-IN DETECTORS DESCRIPTION The Eclipse series intelligent low profile plug-in detectors, manufactured by System Sensor, is a peer-to-peer, all digital protocol that allows for numerous applications such as fire, security, access and HYAC control. Eclipse provides faster device response time, with more flexibility than ever possible before. This digital, peer-to-peer protocol enables pinpoint accuracy in as little as a quarter second - without interference problems that can plague other systems. The Eclipse system distributes intelligence to the networked devices, in fact, Eclipse turns every networked device into a peer, capable of generating messages readable by the entire system. Additionally, with Eclipse, no special communication cables are required, making it ideal for retrofit applications. The isolator versions have on-board short circuit isolators to prevent shorts on the signaling line circuit (SLC) from disabling all devices on the intelligent loop. 63-1052/63-1058. Photoelectric Smoke Sensor Photoelectric provides peer-to- peer digital protocol for reliable, fast communications. The sensor includes a tn-color LED for instant indication of device status. An Accl.imateTM feature is defaulted ON to provide optimum fire detection response. This feature allows sensors to respond to a particular environment and its operating parameters are maintained within non-volatile RAM in the sensor. Dual Alarms (night and day sensitivity) with threshold settings between 1.3 - 3.6%ft. Dual Pre-Alarms with threshold setting between 0.5 - 4.0%ft. 63-1053/63-1059 Photo/Heat Combination Sensor provides peer-to-peer digital protocol for reliable fast communications. The sensor has the ability to alarm from either or both different types of detection and includes a tri-color LED for instant indication of device status. Dual electronic thermistors add 135° F fixed temperature thermal sensing to the standard photoelectronic sensor. Even though this is a dual sensing device, it only uses one address on the SLC loop. 60-1039/60-1040 Thermal Sensor are spot-type heat detectors designed to be programmable for a setpoint range of 135° to 174°F for ordinary detection or 175° to 190°F for intermediate detection. Detectors in the ordinary range may be programmed for either fixed or 15°F rate of rise operation. Additional features include Flame Inbancement and Pie-alarms from 70°-I 50°F. 67-033/67-034 Ion Sensors provide peer-to-peer digital protocol for reliable, fast communications. The sensor includes a tn-color LED for instant indication of device status. An. Acclimate feature is defaulted ON to provide optimum fire detection response. Dual alarms (day and night sensitivity) with threshold settings between 80-50 uAmps MIC are available. Dual pie-alarms with threshold settings between 100-40 uAmps MIC are also available. Configurable for Acclimate, alarm verfication, and drift compensation. 55-051 Configuration JR Tool is designed to communicate with Eclipse devices via infrared signals. The configuration tool will give the user the ability to communicate with the panel and other devices through any selected device on the loop. The 55-051 can read device information such as type, loop, address and sensitivity along with set loop, address, branch and service date. It can also initiate a walk test. The 55-051 features a 16-character liquid crystal display and 17-button keypad. 63-1052 in 63-1054 Base 60-1039 in 63-1055 Base 63-1 2 in 63-1060 Base 67-033 in 63-1060 Base Form No. P.1.52.01-1 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 (816) 229-0314 www.fike.com STANDARD FEATURES/SPECIFICATIONS Sleek, low-profile design Distributed intelligence Greater system design freedom Peer-to-peer communication Digital communication protocol Numerous applications (Fire, Security, Access and HVAC control) Fast response time Superior noise immunity Low standby current Communicate with the devices via hand- held configuration tool Height: 2.1" (51 mm) Diameter: 6.1" (155 mm), installed in 63-1054/63-1060 base; 4.1" (104 mm), installed 63-1055/63-1061 base Shipping Weight: - Heat: 4.8 oz. (136 g) - Photo/Photo with Heat: 5.2 oz. (147 g) Operating Temperature Range: - Photo: 320 to 120°F (00 to 49°C) - Photo with Thermal: 320 to 100°F (00 to 380C) - Thermal: —40 to 100°F (-200 to 38°C); 1350 to 174°F setpornt - High Temperature Thermal: —4° to 150°F (-200 to 660C); 1750 to 190°F setpoint * Spacing for Thermal Detectors: - Detectors set between 135° to 155°F or 1750 to 190°F : 50 foot spacing - Detectors set between 1560 to 1740F: 15 foot spacing Relative Humidity: 0% to 93% RH non-condensing Thermal Ratings: - Fixed Temperature Setpoint: 1350F (570C) - Rate of Rise Detection: 15017/mm. (8.30C/miss.) - High Temperature Heat: 190°F (880C) Voltage Range: 15 - 30 volts DC peak Standby Current (max. avg.): - Thermal: 215 tiA @ 24 \TDC (continuous broadcasts) - Photo/Photo with Thermal: 250 p.A @ 24 VDC (continuous broadcasts) LED Current (Max.): 6.5 mA @ 24 VDC (on) 55-051 Specifications Dimensions: 1.3"H x 2.2"W x 7.7"L Communication Range: Up to 30 feet Battery Life: 168 hours (typical usage) Operating Temperature Range: 320 to 1220F (00 to 50°C) Relative Humidity: 10% to 90% RH non-condensing AVAILABLE MODELS Description Fike Model No. Manf. Model No. Photoelectric Smoke Detector 631052/631058* ED-P/ED-Pi Photoelectric with Thermal 631053/631059* ED-PT/ED-PTI Fixed Temperature/ROR/Hi-Temp Thermal Detector 601039/601040* ED-T/ED-TI Ion Sensor 67033/67034* ED-I/ED-II Mounting Bases 6' Flanged Mounting Base 631054/631060* EBF/EBFI 4" Flangeless Mounting Base 631055/631061* EB/EBI Recessed Mounting Kit 02-10373 RMK400 4" Flangeless Surface Mounting Kit 20-1083 SMK400E 6" Flanged Surface Mounting Kit 20-1084 AI0-29-400 Accessories Retrofit Flange 20-1085 P110 Remote LED Annunciator 02-3868 .RA400Z Detector Removal Tool (20-1089 included) 20-1087 XR2B Extension for 02-4985 (5-15 ft) 02-4986 XP-4 Detector Removal Head 20-1089 T55-127-000 Black Detector Kit 20-1090 BCK-200B Configuration IR Tool 55-051 EA-CT * Indicates models with built in isolators. F*01k POP A ke Copyright © Fike Corporation All Rights Reserved. 11 010 N Form No. P.1.52.01-1 July, 2005 Specifications are subject to change without notice.