Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2234 RUTHERFORD RD; ; AS160033; Permit
5/16/25, 3:50 PM AS160033 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160033 2234 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2120612600 Lot #: 0 Reference No.: Status: ISSUED Applied 2/10/2016 Approved: 2/10/2016 Issued: 2/10/2016 PC #: Inspector: Project Title: WATTSTOPPER ADD (35) PENDANT & (28) UPRIGHT SPRINKLERS FOR NEW T.I. Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION SUITE B 9510 PATHWAY STREET SANTEE CA 619-562-3010 Owner: R C P FUNDING CORP C/O MARVIN F POER AND COMPANY 18818 TELLER AVE #277 IRVINE CA Fees ($) I Add'I Fees ($) JL_____ Balance ($) 303 0 303 0 about:blank 1/1 tqco Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) --__ FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 AS1 60033 2234 RUTHERFORD RD STYLE 150r20 1/2' 7/16" (11,1 mm) RECESSED NPT** NOMINAL MAKE-IN ESCUTCHEON WF Fl TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly *Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. ESCUTCHEON PLATE 6 - Deflector DEFLECTOR* SEATING SURFACE 7/16 1 \ (11,1 mm) NOMINAL 2" MAKE-IN _____ (50,8 mm) 2' NJ CV 1-3/8' (50,8 mm) ________ (34,9 mm) __ 1/2" NPT** DEFLECTOR * -..---- 2-7/8' (73,0 mm) DlA. -.- 4 - Bulb 5 - Compression Screw CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT QUICK RESPONSE / WRENCH RECESS / (USE ONLY 60~ FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F(141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over,the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8' DIA. -. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER I FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16' (9,5±7,9 mm) 1 I 17, MOUNTING /8" SURFACE (3,2 mm) J CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER _ 2-1/4" DIA. FITTING I (57,2 mm) (7,9±6,4 mm) \ II FLUSH 5/16±1/4" 1/2(12,7mm) /e(3,2 —i--i " J I T_ i MOUNTING / SURFACE/m) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER TEMPERATURE FINISH RATINGS -- SIN 1 NATURAL BRASS 370 56K UPRIGHT (1/2 NPT) TY313 3 PURE WHITE (RAL9010)°° POLYESTER 4 SIGNAL WHITE (RAL9003) 371 5.6K PENDENT (1/2 NPT) TY323 POLYESTER Use suffix I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only 135 135°F(57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (PIN). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. tijco Fire Protection Products lilt Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ____________ Pressure Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar -200 to 1500 -28.90 tc 300 20.7 65.6° 500 34.5 6C0 41.4 2000 93.30 265 18.2 455 31.4 550 37.9 2500 121.1" 225 15.E 405 27.9 505 34.8 3000 148.9° 165 12.6 30 24.8 40 31.7 3500 176.7° 150 10.2 35 21.7 415 28.6 4000 2044° 110 7.6 270 18.6 370 25.5 4500 232.2" 75 5.2 225 15.5 325 22.4 5000 260.0' - - 180 12.4 280 19.3 5500 2878' - - 130 9.0 230 15.9 Note: Unions wi:h Copper or Copper Alloy seats Ere not intxnyed for use where temperature exceeds 450°F ci(gus APPROVED For Listings/Approval Details and ..imitat ons, visit our webite © www.anviliitl.com or contact an Anvil/ArvilStar Sales ReprEsentative. MalleabI3 Iron Threaded Fittings Pressure - Temperature Fatings Temperature Pressure Class 150 Class 300 ___________ Sizes -1° (6-25 mm) SiCS11/4"-2° (62-51 mm) Sizes 21/2 -3" 64-76 mm) ('F) (°C) psi bar psi bar psi bar psi bar -200 -28.9° :0 h 1500 65.60 300 20.7 2,000 1379 1,500 103.4 1,000 68.9 200° 93.3 265 18.2 1,785 123.1 350 93.1 910 62.7 253° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3)30 143.9 185 12.6 1,360 93.8 1,050 72.4 735 50.7 3530 176.7 150 10.2 1,150 79.3 900 62.1 650 44.8 4)3° 204.4 - - 935 64.5 750 57.7 560 38.6 4530 232.2 - - 725 50.0 600 47.4 475 32.8 5)30 260.0 - - 510 35.2 1 450 31.0 385 26.5 553° 287.8 - - 1 300 20.71 330 20.7 300 20.7 Co ii Arvil Class 1E0/300 Mztleable Iron Fittings conform to ASME j B16.3 and Unions conform to ASME B16.3.. co 1 AL.. ELBOWS & TEES %" (1('DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 10) PSI. (6.2 bar) *ANVIL PF-1110 _ Dyna-Flow 0 - M-COAT® High Strength Steel Pipe Dyna-Flow Specifications NIPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kglrn unthreaded 1.191 0.830 1.31 2.41 25 30.3 1.2 1.95 - 11/4 1.059 1.87 1.55 32 39.0 1:6 2.78 - 11/2 1.667 2.71 3.44 40 - 43.9 - 2.5 4.03 - 2.203 2.104 3.79 2.78 50 56.0 3.1 5.64 - 21/2" 2.703 2.564 5.10 1.60 65 68.7 3.8 7.59 - 3.314 3.387 7.18 1.48 75 84.2 5.0 10.69 - 4.310 4.473 10.86 1.00 100 - 109.5 6.7 16.16 - Exceptional hydraulics Lightweight and easy to install Available factory roll grooved M-COATID UL and cUL listed FM approved > The original high-strength light wall sprinkler pipe with superior hydraulics. Dyna-Flow® - M-COAT® is the original" high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow - M-COAT is recognized as the most popular alternative to Schedule-lU pipe. Lightweight and easy to cut Dyna-Flow - M-COAT is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-4C and up to 7% larger than Schedule -10, Dyna-Flow-- M-COAT pipe hydraulics are exceptional. Larger ID's enable Dyna-Flow - M-COAT and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to "Dyna-Flow M-COAT Hydraulic Datai Tables". Dyna-Flow - M-COAT pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special prccesses or equipment needed for fabrication and installation. > Superior Coating Dyna-Flow - M-COAT products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products are coated with M-COAT, an advanced MIC coating that is FBCTM system compatible for hybrid sprinkle systems. FUC system compatible indicates that this product has been tested, and is monitored on an ongoing basis, for chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings.* ) American Made Able to meet" Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. ) Specifications & Approvals Dyna-Flow - M-COAT pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA- 14. All sizes of Dyna-Flow - M-COAT are UL and cUL listed and FM approved. Dyna-Flow -- M-COAT is UL and cUL listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow - M-COAT is available "hot-dip" galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow - M-COAT complies with NFPA 13 and is rated at 300 psi working pressure. * FBcTM, FlowGuard Gold?, 8lazeMaster, and corzan* are licensed trademarks of The Lubrizol Corporation ** Must be ordered in 10 bundle increments - fl - _ Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com ~j '!' QHIC) • 16100 S Lathrop Ave • 11350 Norcom Rd • 2525 N 27th Ave • 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 , ........- ----------- NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR - CRR ,In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn Unthreaded Threaded 1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 - - 1¼ 1.408 1.870 2.54 9.50 1.00 r32 35.8 2.8 -. 3.78 - - 11/2 1.639 2.290 3.22 9.14 1.00 j40 41.6 3.4 4.79 - - 2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 - - Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-f it applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thi:kness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread pipe is manufactured to meet: ASTM A 135, Type E Grade A, and is in compliance with NFPA-1 3. All sizes of Dyna- Thread are rated at 300 psi working pressure. Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread can be hot-dip galvanized* to meet FM requirement for dry systems. Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). APPROVED * Must be ordered in 10 bundle increments. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: alhed Customer Service (800)882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com !! 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. 600 Dean Sievers Place TUBE & CONDUIT, Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 I U FireLock® Outlet-T STYLE 922 ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for cther optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com Ai VIcTAULIc ISA REGISTERED TRADEMARK OF VIcTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. taulic REV G 1.0.52 1 PS CARBON STEEL PIPE HOLE CUT PRODUCTS iU.3 Size Dimensions - inches/millimeters 7~1 1¼ ½ 15 1 3Ao 30.2 130 1.83 1.10 3.87 2. 32 33.0 46.5 27.9 98.3 65 3/4 1 3A6 1.28 1.83 1.10 3.87 2.56 1 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1/l6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 ½ 40 15 13/16 30.2 1.42 36.1 1.95 49.5 1.22 31.0 4.08 103.6 2.56 65.0 1.2 0.54 ~ 13A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31,0 103.6 65.0 0.54 1 25 1 30.2 1.64 41.7 2.30 58.4 1.22 31.0 4.08 103.6 2.56 65.0 1.3 0.59 2 ½ 50 15 1 30.2 1.66 42.2 2.19 55.6 1.46 37.1 4.60 116.8 2.56 65.0 1.3 0.59 3/4 1 3/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 478 645 371 116.8 65.0 0.68 2½ 112 65 15 1 /6 30.2 1.91 48.5 2,44 62.0 1,71 43.4 5.40 1372 2.56 65.0 1.6 0.73 3/4 1 '/16 1.89 2.44 1,71 5.40 2.56 1.6 20 1 30.2 11/'6 48.0 2.13 62.0 2,79 43.4 1,71 137.2 5.40 65.0 0.73 2.56 1.6 25 112 76.1 mm X 30.2 13A6 54.1 1,91 70.9 I 2.44 43.4 1.71 137.2 5.50 65.0 0.73 2.56 1,6 15 30.2 48.5 62.0 43.4 139.7 4 . 65.0 0.73 3/4 20 P/i6 30.2 1.89 48.0 2.44 62.0 1.71 43.4 5.50 139.7 2.56 1.6 65.0 , 0.73 1 13/16 2.13 2,79 1.71 5.50 2.56 1.7 25 30.2 54,1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS i. 411 II 'L AVI ,._.• f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VIcTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 \4taulici REV ( IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS iu. FireLock® Outlet-T STYLE 922 PERFORMANCE Run Size Outlet x Size Equivalent Length of 1 in Schedule 40 Steel Pipe (per UL 213 Section 16) (C12O)* FT 32 25 2.6 x so J. x 25 21/2 1 65 25 Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Ac-taUlic RFV ( FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com '1'tauhc 10.52 3355 REV G UPDATED 12/2009 VIcTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAIJLIc COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEELJCPVC 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - Cl@ us LISTED 203-EX 25511"- 8" c.ApprovaI guide - i"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an A.FCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I Wi. 5 WT.°250 UL TEST LOAD 1 3/8 3075 40375 750 /1/4 3/8 43.95 469,75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 8 1/2 476.35 2631.75 2650 8 1/2 1 711.00 1 3805.00 4050 -551 310 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE.. One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c(oDLus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE; When installing on CPVC Sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCOjV products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply, DISC LAIMER. AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCOTV. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. =I 1/08 1/4" 8002957 GST 100 1/4x1" 25 ij 114" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 114" 8004957 GST 300 1/4 x 3 2060 (Fir) - 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 210 (7/16"OSB) 25125 1 3/8' 8007957 GST 10 1/4x 10 300 3/8 8008957 GST 201/4x2 1760(Fir)850 1475 25125 3/8__806 ' GST 20_SS1/4x2_-1760(Ar) 850 -25125 3/8' 8009925 GST 25-380 3/8x2-112" 2113 (Fir) 1500 25 125 _______ 301/4x3_2060(Ar) 1500 475 5 3/80 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25125 8011925 GST 40 1/4x4 2180 (Fir) -25125] 3/8" 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25_ 125 1/2"8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 r 1/2__8015925 GST 3 1/4x3__2275 (Ar) - 25 --12-57 1/2"8016925GST 4 1/4x4"2180(Fir) 25 - 125 J.017925 __GST6 1/4 x 6 2230 (Fir) ___________ 125 4 #14 Black Nut Driver Part # 8113910 -'I #14 SW Red Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 /2" x 12 pitch roof. • Reduces installation cost. Allows 17 deflection from vertical. • Made in the U.S.A. 3/8__8139957SF-l-GST20 1/4x2"1257 (Fir)1050 1475 25 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 SPECIAL NUT DRIVER SYSTEM- The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 -7 'JV 1L1 -A (b MALt IN U.4M 4 #14 Black Nut Driver Part if 8113910 Not less than 2' nominal width (1-1/2') up to 3-1IDips; not less than 3' (2-1/2') nsminu xidth 4' & 5 pipe 4 j Minimum 2-1/2' from bottom for branch lines. Minimum 3' from bottom for mainlines. Exception: This requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. Product Features Floor 'No pre-drilling required. 'Quick to install using the Sammy I Nut Driver with an iSV cordless I drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. iF #14 SW Red Nut Driver Part # 8114910 .1JJ4 8018957 SWG 100 1/4x1' 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/402' 1725 (Fir) 25 125 8020957 SWG 1 1/4x1 622 (Fr) 300 25 125 /lll. 3/8' 8021957 SWG 20 1/4x 2' 1725 (Fir) 1050 25 125 " I13/8 8073925 SWG 20 SS 1/4 x 2 1725 (Fir) 850 25 125 ll.. 3/8' 8022925 SWG 25-380 3/8 x 2-1/2' 2249 (Fir) 1500 25 125 1)3/8 8023925 SWG 30 1/4x3 1884 (Fir) 25 125 Insert the appropriate nut driver into a. 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to :the member. When the nut driver spins freely on the SAMMYS, stop drill and remove The SAMMYS is now ready to receive 1/4", 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" rec uires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 fcrt lbs. for maximum pullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, ontinue drilling until nut driver spins tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.