2234 RUTHERFORD RD; ; AS070005; Permit
5/22/25, 9:29 AM AS070005 Permit Data City of Carlsbad Sprinkler Permit 2234 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2120612600 Lot #: 0 Permit No: AS070005 Status: ISSUED Applied 1/11/2007 Approved: 1/11/2007 Reference No.: Issued: 1/11/2007 PC #: Inspector: Project Title: 24 HOUR FITNESS DETECTION SYSTEM 3 INSPECTIONS @ $62/EA Applicant: FACILITIES PROTECTION SYSTEMS SUITE D 1150 W.CENTRALAV BREA, CA Owner: RUTHERFORD ROAD LLC C/a STONERIDGE CAPITAL PARTNERS 4350 VON KARMAN AVE #400 NEWPORT BEACH CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 186 0 186 0 about:blank ill VESDA EARLY WARNING DETECTION SYSTEM ENGINEERING SUBMITTAL V FOR 24 HR FITNESS 2234 RUTHERFORD RD. 4 CARLSBAD, CA APPROVED SJBMITTED 10-31-06 PROVIDED BY: FACILITIES PROTECTION S YSTEMS 1150 W. CENTRAL AVE. SUITE "D BREA, CA 92821 TEL: 714-257-2244 FAX: 714-257-2240 C.L.#592289-C1O/C16 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0900:137 Page 1 of 2 CATEGORY: Control Unit (Non High-Rise) LISTEE: Fike Protection Systems, 704 S. 10th St., Blue Springs MO 64015 Contact: Brent Mlika (816) 229-3405 X 1220 FAX (816) 229-5082 DESIGN: Model CyberCat 1016 or 254 control unit, part no. 10-064-c-p-d or 10-066-c-p-d (c: R=Red or B=Black; p: 1120V or 2=240V; d: B=Blank or L=Lexan) fully addressable *fire alarm control panel. Base configuration includes the main board, enclosure and a transformer. *Suitable for critical process management and voice evacuation via Fike Guard model FGX- MP/DP. *Model Cheetah Xi 10-068 Fire Suppression Control Unit. Local, auxiliary, remote and central station service. *Model Cheetah Xi also suitable for releasing service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 10-2472, 2525,*2542 Controllers 10-2473 Supplemental Loop Module 10-2474 Supplemental Power Supply 10-2204 CRM4 Relay Module 10-2254 Reverse Polarity Module 10-1 832 Agent Releasing Module Ill *102482 Network Card FGX-MP/DP Voice Evacuation System *24..001 thru 24-012 Master Panel Voice Evacuation System *24..01 3 thru 24-024 Distribution Panel Voice Evacuation System *10-2541-C Enclosure *102541CL Enclosure with Lexan 10-2483-C or -C-L Enclosures 10-2476 DACT 10-2321 Remote Display *10-11X LED Display Graphic 10-2413 Masterbox Supervision Module 10-2361 Series Impedence 10-2373 Zone Annunciator *55..052 -053 Releasing Module *55042 Control Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. *rev 10-07-2005 jew Listing No. 7165-0900:137 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *rev 10-07-2005 jew Z.' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 20, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Fike Cheetah Xi APPROVALS UL S2203 FM 3023436 : I FIKE CHEETAH XITM INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike's Cheetah Xi P/N 10-068) is a state-of-the-art true intelligent digital peer-to- peer modular suppression control system. It is ideal for all life safety and property protection applications, and is intended for both commercial and industrial use. It is designed with extensive programmability that allows the almost-instantaneous relay of information and the ability to perform process management tasks with ease including shutdowns, HVAC, Voice Evacuation Systems, Dampers, Doors, Elevators, and Security, CCTV/Building Management Awareness. This cost-effective panel comes standard with two Signaling Line Circuits (SLC) thatsupport 254 devices each. This is expandable to four loops and a total panel capacity of 1016 devices, with any mix and match of sensors and modules. The Cheetah Xi utilizes extreme intelligence via itsciild -sensors -including photoelectric, photoelectric with heat, ionization, photoelectric duct, and heat detectors. It also utilizes Eclipse based modules such as the monitor, mini- monitor, relay, intelligent pull station, releasing and control modules. With Cheetah Xi, every device communicates as a peer on the signaling line circuit. These peers not only communicate up-to-the-second information to the control panel, but also communicate with each other. Each device is capable of generating accurate and highly detailed information. Conventional suppression alarm systems give a general idea of the fire's location, while the Cheetah Xis intelligent sensors indicate precisely which device is in an alarm state. This intelligence provides incredible speed with response times as little as one-quarter second between manual pull station and notification appliance. It's flexibility allows you to attach the intelligent devices that are required for your specific application. The System is programmed with either the Windows based field configuration software C..LLNX1M or through a comprehensive password protected front-panel keypad programming option. This option allows you to quickly update and adapt to any future requirements or changes in the system such as changes in occupancy or remodeling. The sophisticated control panel circuitry coupled with the software allows you to read specific information and sensitivity levels of the different eclipse devices. The sensors also compensate for any changes due to age, contamination, or other environmental factors. System Operation The Cheetah Xi Control system operates on a "Zone and State" relationship. In this design, all input and output devices must be assigned to at least one zone or to all zones (254 are available), each one defining an area to be protected. Input devices can be assigned up to four zones (one zone is typical) and output devices may be configured for up to 254 zones. These devices use the SLC signaling line circuits to exchange status information with other devices as well as with the control panel. When an input is activated, it is configured to cause its associated zone to enter into an operational state. Any detection device will cause the associated zone to enter into an alarm state. The output devices are configured to activate to protect and evaluate the endangered zone. This system is completely modular, allowing you the flexibility to design a system that is just right for your application. A typical configuration is shown on page 2 that illustrates the communications of a Cheetah Xi system. I Form No. D1.10.01 I 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229.3405 (816) 229-4615 www.fike.com DESCRIPTION (Cont.) vD;: cPIuA I. /< >I Photo D:tr s. NACMo Chsscuh Xi Ptos .. Reiay Releasing Module P. tc-'n Prnccss NI - nrash, Such As: S.:,c':-crc..'r_,n, - • G,,usCU')nA 'I. STANDARD FEATURES/SPECIFICATIONS The Cheetah Xi features are designed to save lives and protect your valuable capital investments through unprecedented speed, intelligence and flexibility. These features include: General Two 24VDC, 2A N.AC (bell) circuits on main board with built in System Sensor or Gentex synchronization protocol 254 user defined zones 80 character, backlit LCD display Real time clock 3200 event history buffer Critical process monitoring One-person Walktest capability Disable by zone Drill function at panel and remote Provides solenoid releasing operation Alarm verification Easy to add/remove devices Diagnostic menus Removable terminal blocks for field wiring Local piezo with distinct event tones 10 Status LEDs to easily identify system status Optional point ID DACT Module available Supports up to 31 peripheral devices such as Remote Display, LED Graphic and Zone Annunciators Page 9 Page 3 STANDARD FEATURES/SPECIFICATIONS (Cont.) Power 6 amps useable alarm power, expandable to 12 amps (2 A standby/expandable to 4) Operation from I20VAC/60 Hz or 240 VAC/50 Hz Two 24V DC, 2A continuous auxiliary power outputs (Expandable to 5 circuits with SPS) One 24VDC, 2A resettable auxiliary power output Supports up to 75AH of batteries, expandable to 150 AH using SPS Signaling Line Circuit Address devices with Infrared (IR) tool, similar to remote control device Two SLC loops, expandable to four, NFPA style 4 or 6 254 devices per loop, system maximum 1016 devices with SLM (Supplemental Loop Module) True peer-to-peer digital protocol for extremely fast and reliable communications Auto-learn function Automatic day/night sensitivity adjustment Automatic holiday sensitivity adjustment Acclimate operation for sensors IR Tool provides ability to read sensitivity levels or perform remote test of device Devices contain multi-color LED for quick reference of device status Sensors provide early warning pre-alarm detection and can also provide a summing feature. (up to eight sensors) NAC Circuit Two NAC circuits standard Rated at 24VDC, 2.0 Amps maximum Built-in synch protocol for both System Sensor and Gentex devices CONTROL SYSTEM MODULES Cheetah Xi Controller (P/N 10-2542) The Controller contains the power supply, microprocessor, hardware interface, display and keypad. The controller's internal power supply provides 2 Amps Normal Standby Current/6 Amps Alarm Current. Comes standard with two signaling line circuits (SLCs). Enclosure Steel Enclosure 21.10" H x 14.35" W x 4" D (Back-box dimensions) Enclosure is equipped with a 0.50" wide lip to facilitate flush mounting Removable door for ease of installation Two door options available; with or without lexan cover on oval opening Available in red or grey Dead Front option available Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 10-2528) The DACT provides interface with Central Station monitoring systems. It is available with 5 contact zones of connection OR the intelligent serial interface which provides point ID information. The Contact ID form is the preferred reporting format. It provides a four digit account code followed by a three digit event code, a two-digit group number, and a three digit contact number, all of which are used to provide specific point identification. This DACT can also provide an SIA or 4/2 Pulse reporting format. Note: 10-2476 is the same as 10-2528 with enclosure for external mounting. Jz1 - - -. --_; ThLT CONTROL SYSTEM MODULES (Cont.) Supplemental Power Supply (SPS) (P/N 10-2474-P) The 10-2474-p includes the power supply circuit board and transformer (-1 for I20VAC primary; -2 for 240VAC primary). This module adds up to 2.OA external standby power and 6.OA alarm power (4 A standby/12A alarm total). AC power and standby batteries are supervised. Supports charging up to 75Ah of additional standby battery. Charging may be turned off in configuration if batteries are not required on SPS. Dimensions: 4-1/2" Lx 5-1/2" H x 2" D. Weight: 0.66 lbs. Supplemental Loop Module (SLM), (P/N 10-2473) The SLM adds two more SLC loops. Loop specifications and wiring for SLM are the same as' the main controller. It interfaces to the main Control Panel using four standoffs supplied with the SLM. Dimensions: 2" L x 6-1/2" H x 1" D. Weight:: 0.12lbs. Fike Relay Module (P/N 10-2204) The CRM4 provides 4 additional independently programmed relays. Cheetah Xi Control Panel supports up to 2 CRM4 modules (if either options are not unused) on the main controller board. Each relay may be wired across normally open or normally closed contacts. Dimensions: 3-1/2' L x 1-1/2" I-I x 2" D. Weight:: 0.10 lbs. Fike Reverse Polarity Module (CRPM) (P/N 10-2254) The reverse polarity module provides the ability for UL Remote Station supervision. This supervision is typically performed with a direct, leased line connection. It interfaces to the main control board using four standoffs supplied with the RPM. Dimensions: 3-1/2" L x 1-1/2" H x 2" D.. Weight: 0.08 lbs.. Fike Remote LCD Display (P/N 10-2321) This module provides information about the host Cheetah Xi System in a remote location. It receives the intelligent data stream from the RS485 output of the Cheetah Xi. The remote display provides the capability to remotely reset, silence, and acknowledge the main control panel. Security to the unit is available via the standard Fike key. It mounts to a 5 gang masonry box (Raco 694). The unit can be surface or flush mounted. Dimensions: 9-7/32" L a 3-3/4" H x 2-1/2" D. Weight: 2 lbs. Fike Zone Annunciator (P/N 10-2373) The Zone Annunciator provides instant visual status of up to 10 zones of fire protection. Each zone has a red Alarm LED and yellow Trouble/Supervisory LED. Each LED is individually programmable for zone(s) and state(s). Each LED can be labeled using Avery Label 6467 or 5418. The annunciator also has an internal piezo to provide instant audible notification of status change. It is intended to be powered via the Cheetah Xi panel 24VDC auxiliary power. It communicates with the main control panel via RS485 communication. The annunciator provides the capability to remotely reset, silence and acknowledge the main control panel. Security to the unit is available via the standard Fike key. It mounts to a 5 gang masonary box (Raco 694). The unit can then be surface or flush mounted. Pae4 Fike Network Module (P/N 10-2482) The Network Module provides the ability to network up to 128 control panels. This typically . would consist of other Cheetah Xi panels or CyberCat fire alarm panels. The Cheetah Xi network uses a "common zone' functionaht) Zones 1-254 are common to all panels on the I network and any input will cause activation of all outputs for the same zone, regardless of which panel the devices are connected to. Regardless of zone number, every state (alarm) . ..j trouble etc.) that occurs is displayed by all panels on the network. The Cheetah Xi network is peer-to-peer which allows each panel to operate independently in the event that the network wires are damaged. CONTROL SYSTEM MODULES (Cont.) The following system modules are available for the CyberCat Control System Part Number Description 10-068-c-pl Cheetah Xi System-Includes Controller, Enclosure, and Transformer c:(R=Red, G=Grey) p:(l =120V, 2=240V) 1= with lexan 10-2542 Cheetah Xi System Controller (included with 10-064-c-p-d) 10-2528 DACT, 5 zone with Serial interface 10-2474-p SPS - Supplemental Power Supply p: (1=120V, 2=240V) 10-2473 SLM - Supplemental Loop Module (adds 2 loops; 254 devices ea.) 10-2204 CRM4 - Relay Module 10-2254 CRPM - Reverse Polarity Module 10-2321 FIKE Remote Display 10-2373 Zone Annunciator 10-2482 Network Module 10-lix LED Graphic 10-2519-c Dead Front Option c: (R=Red, GGrey) CHEETAH XU/PROGRAMMING CONFIGURATION Software All configuration variables can be assigned using C-LINX software. This software provides the designer the capability to provide a pre-engineered design. The user can review the construction plans to assign the zones. The configuration can also be set to identify the exact device circuit operation desired along with the custom message information. Page 5 POWER LIMITED 04000 AUXILIARY OUT P UTS . 20 max. each . . 0 LOOP SLC MODULE (lLl62OY) LE ,2K EG OPTIONAL CRM4 JR Configuration Tool This optional hand-held infrared remote control is available on the Cheetah Xi system. This small device can be used in the field to simplify installation, testing and service. It operates with 2 AA batteries and can read device information such as loop, address, branch and service dates and initiate device test. This tool: Communicates bi-directionally with any Cheetah Xi device Easily addresses devices by setting the loop and address Quickly reads sensitivity levels, date serviced, device type, loop and address, manufacture date Immediately records the date serviced Instantly initiates walk test of any sensor or module Accesses and tests hard-to-reach sensor or module (such as duct detector) through any other device on loop Field Wiring Although the installation instructions provided for each module should be used for installation, please see the a general wiring diagram on the following page. Wiring Specifications Maximum Resistance: 70 ohms Maximum Capacitance: .06 uf 12,000 ft. maximum distance total from panel to last device Field Wiring Diagram 5) t______________ I FIKE CU/U I OPTIONAL DACT 10-2528 Pei 0 tL :", OP11 I RELAY CRM4ORCRP I I 10.2204110-2254 0----- © The following parts are used for configuration, testing and diagnostics of the CyberCat Part Number Description 55-051 Infrared (IR) Remote Control Tool for Programming/Testing Devices 06-327 C-linx Software 10-1874A Interface Cable for C-linx Software (DB9 to RJ 11) 10-2477 DACT Programmer Page 6 CHEETAH XI INTELLIGENT DEVICES Photoelectric Smoke Sensor (P/N 63-1052/63-1058) The photo sensor provides peer-to-peer digital protocol for reliable, fast communications. The sensor includes a tn-color LED for instant indication of device status. An acclimate feature is defaulted ON to provide optimum fire detection response. This feature allows sensors to respond to a particular environment and its operating parameters are maintained within non-volatile RAM •/ in the sensor. Dual Alarms (night and day sensitivity) with threshold settings between 1.3 - 3.6%ft. Dual Pre-Alarms with threshold setting between 0.5 - 4.0%ft. Photo/Heat Combination Sensor (P/N 63-1053/63/1059) The photo/heat sensor provides peer-to-peer digital protocol for reliable fast communications. The sensor has the ability to alarm from either or both different types of detection and includes a tn-color LED for instant indication of device status. Dual electronic thermistors add 135° F fixed temperature thermal sensing to the standard photoelectronic sensor. Even though this is a dual sensing device, it . ) only uses one address on the SLC loop. Thermal Sensor (P/N 60-1039/60-1040) The thermal sensor provides peer-to-peer digital protocol for reliable fast communications. The sensor includes a tn-color LED for instant indication of device status. The spot-type heater sensor is designed to be programmable for a set- point range of 135° F to 174° F for ordinary detection or 175° F to 190° F for intermediate detection. Detectors in the ordinary range may be programmed for } either fixed temperature or 15° F rate of rise operation. The detection set-point is software programmable in single degree increments from 135° F to 190° F. Sensor Base (P/N 63-1054/63-1060 6" and P/N 63-1055/63-10614") The 6' sensor base will mount directly to 3-1/2 " and 4" octagon boxes, . 7 4" square boxes (with or without plaster rings) and single gang boxes. The base is approximately 2 inches larger than the sensor, providing a contouring effect and covering the junction box. It is used with any of .. the Cheetah Xi sensors. Fully programmable LED feature also available. A4 Ion Sensors (P/N 67-033/67-034) Ion Sensors provide peer-to-peer digital protocol for reliable, fast communications. The sensor includes a tn-color LED for instant indication of device status. An acclimate feature is defaulted ON to provide optimum fire detection response. Dual alarms ((lay and night sensitivity) with threshold settings between 80-50 uAmps MIC are available. Dual pre-alarms with threshold settings between 100-40 uAmps MIC are also available. Configurable for acclimate, alarm verfication, and drift compensation. INTELLIGENT MODULES Fike's intelligent modules provide a fire alarm dry contact device directly connected to the Cheetah Xi intelligent loop. Each module may be assigned to a single zone or up to four zones. Any number of UL hated contact closure devices may be used. Mini-Monitor Module (55-045/55-050) 2-3/4" x 1-3/4" miniature module for mounting in the small junction box behind a monitoring device. This device will monitor a Class B wired input device using the 39K ohm end of the line resistor. Short circuit detection feature also available. Page 7 4" Square Monitor Module (55041/55-046) Mounted with cover plate on a 4" square junction box. This device will monitor a Class B __ or Class A wired input device. Class B wiring requires a 39K ohm end of line resistor. Short circuit feature also available. M Pull Station Monitor Module (P/N 20-1063/204064) The intelligent pull station has all of the same addressable input module electronics inside the pull station for one complete addressable pull station. Activation is accomplished by pushing in and pulling down as instructed. A hardware key is issued to reset the device. 40 Supervised Control Module (P/N 55-042/55-047) The Supervised Control Module (SCM) provides building notification appliance circuits (NAC), an intelligent interface to the Cheetah Xi Intelligent loop. It also has the capability IL of operating solenoids rated up to 2 amps @ 24VDC. Mounts in a 4" x 4" x 2-1/8" junction box. Relay Module (P/N 55-043/55-048) The Relay Module provides building dry contact output interface via the intelligent loop. Two configurable (single operation) relay Form C contacts rated for 2 Amps @ 30\'T)C, 0.5a @ 120VAC. Wide range of operating modes including multi-zone operation, up to 4 different states and multi-state programming. Operating parameters are maintained in non- volatile RAM for quick and reliable response to emergency conditions. This module mounts on a 4" x 4" x-2-1/8" junction box. Releasing Module (P/N 55-052/55-053) Releasing Modules is designed to provide reliable operation of a solenoid or Agent Release Module ARM) for clean agent, carbon dioxide and pre-action prinkler/deluge system actuation. Each releasing module is protected from inadvertent operation by an intelligent switch, which requires transmission of a complicated code before activating the releasing output. This module is capable of providing up to 2.0 amps @ 24 VDC of output power for solenoid applications. The releasing module requires a separate 24 VDC power source in addition to the SLC. Duct Sensor (Sensor is P/N 63-1057/63-1062; Housing is P/N 63-1056) The Duct Housing contains a circuit board that provides connection to standard remote accessories and also provides a relay contact output that transfers upon activation of the DUCT detector. Four different lengths of sampling tube are available for duct penetration: Length Part Number 1.5' 02-3721 3.0' 02-3722 5.0' 02-3723 10.0' 02-3724 FI ke Copyright © Fike Corporation All Rights Reserved. o PP PAT ON Form No. D.1 .10.01 July, 2005 Specifications are subject to change without notice.