HomeMy WebLinkAbout2231 RUTHERFORD RD; ; AS030194; Permit5/22/25, 10:00 AM AS030194 Permit Data City of Carlsbad Sprinkler Permit 2231 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2120701900 Lot #: 0 Reference No.: PC #: Project Title: MEDEX Permit No: AS030194 Status: ISSUED Applied 9/18/2003 Approved: 10/6/2003 Issued: 10/6/2003 Inspector: Applicant: Owner: BECKMAN/CARLSBAD I L L C C/O COVEY COMMERCIAL 6183 PASEO DEL NORTE #280 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) H------ 100 - -±---'-- 0 --j 100 --___ 0 about:blank 1/1 CARLSBAD FIRE DEPT FAX NO. 7609290256 P.01 CARLSBAD FIRE PROTECTION SERVICES Permit Submittal Form A. Check or fill in pertinent information for type of permit you are submitting. AS - Automatic Sprinklers VJZ'44t2tI Commercial _— Residential_____________ Number of heads per System: System #_i Hcads_aa System #_ Heads_____ System # Heads System # Heads_____ System # Heads System # heads_____ Underground included for approval Underground included for reference only Total Fees b FA - Fire Alarm 10 devices or less Over 10 devices # of devices FS - Fixed Systems (Circle One) Hood & Duct, Halón, Special Chemical Agent, Standpipe, Spray Booth, or Appliance. Total Fees!:-. There may bee an additional fee of $50.00 per 4 hour for Failed Inspections. Address ofjob site 723 M. Suite #lCri LL ç , sbc4 C.t. Building Permit # CR - 03Z k 31 Contractor Information Name o-eJco Address 4-10 1-ku_(2e. City, Stale, Zip)O C.\'i.t2- Kind of License and number C- Z--70,3Q9 Phoncs2 - LI? '- I ZZ Certificate of Insurance on file with Fire Dept.? &or N Business License on fir with City? dOor N ~ =r ~e ~ Z~-D~2 Date- 5-c Ociober 1, 2000 Sprinkler 41 a - MICROFASTe AND MicrofasU1Pe QUICK RESPONSE PENDENT SPRINKLERS PRODUCT NAME Viking MicrofastO and MicrofastHP0 Model M Quick Response Pendent Sprinklers MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (616) 945-9501 (877) 384-5464 Fax: (616) 945-9599 e-mail: techsvcs@vikingcorp.com PRODUCT DESCRIPTION Viking Microfast° and MicrofastHP Quick Response Pendent Sprinklers are small, thermosensitive spray sprin- klers available with several finishes, temperature ratings, and orifice sizes to meet design requirements. The special Polyester finishes and TefionS coatings can be used in decorative applications where colors are desired. In addition, these two finishes are corrosion resis- tant and provide protection against many corrosive environments. The pip-cap and sealing assembly of the sprinkler is held in place by a rugged 3 mm glass bulb. During fire conditions, when the temperature around the sprin- kler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, re- leasing the pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler de- flector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS Refer to the approval chart on page 41 b. Glass-bulb fluid temperature rated to -65°F(-55°C). Minimum operating pressure: 7 psi (48,3 kPa). Rated Water Working Pressure: Sprinkler Base Part Nos. 06662B, 067188, and 069328 are rated for use with water working pres- sures ranging from the minimum 7 psi (48,3 kPa) up to 250 psi (1 724 kPa) for high-pressure sys- tems. High-pressure (HP) sprin- klers can be Identified by locat- ing the number "250" on the de- flector. All Other Part Nos: Maximum 175 psi (1 207 kPa) wwp. Factory tested hydrostatically to 500 psi (3 448 kPa). Spring: U.S.A. Patent No. 4,167,974 Bulb: U.S.A. Patent No. 4,796,710 Testing: U.S.A. Patent No. 4,831,870 Minimum operating pressure: 7 psi (48,3 kPa) SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector Brass UNS-C26000 Bushing (for High-Pressure Sprinklers): Brass. UNS-C36000 Bulb: Glass, nominal 3 mm diameter Seal: Teflon Tape Spring: Nickel Alloy Screw: Brass UNS-C36000 Pip Cap and insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Sprinklers with Polyester Coating or Poly Finish Spring: Nickel Alloy, exposed Screw: Brass UNS-C36000 Nickel plated. Pip Cap and Insert Assembly: Copper UNS-C1 1000 and Stainless Steel UNS-S30400 Sprinklers with Teflon0 Coating Spring: Nickel Alloy, exposed Screw: Brass UNS-C36000 Nickel plated. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400, Teflon* Coated AVAILABLE FINISHES Brass, Bright Brass. ChronleEnloya (patents pending), White Polyester (White Poly finish for P/N 0666213 only), Navajo White Polyester, Black Polyes- ter (Black Poly finish for P/ti 06662B only), and Black let Ion0 ACCESSORIES Sprinkler Cabinets: Six-head capacity: Part No. 01724A Twelve-head capacity Part No. 01725A Available since 1971. Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) or 05000CW/B (no longer avail- able). Wrench for coated and recessed Viking MicrofaatHP0 Sprinklers: Part No. 07398W' A 1/2° ratchet is required (rot available through Viking). Refer to the "SPRINKLER ACCES- SORIES' section of the Viking Engi- neering and Design Data book. Sprinkler Nominal Sprinkler Ceiling Temperature at Sprinkler Bulb Max. Ambient Max. Recommended Temperature Temperature Rating Colt ClassIfication (Fusing Polnt) 135 'F (57 °C) Tame. Allowed' Anlblent Temp.! Ordinary 115 'F (46 'C) 100 'F (38 'Cl Orange Ordnary i155°Fi68CV 135 'F (57 'C) 100 OF (38 'C) -Rêd7 Intermediate 175°F (79 'C) 155 OF (68 °C) 150°F (65 'C) Yellow Intermediate 200°F (93 'C) 180°F (82 'C) 150°F (65 Green High 288 'F (141 'C) 266 'F (130 'C) 225 'F (107 'C) J Blue Sprinkler Finishes: Brass, Bright Brass, Chrome-Enloy (patents pending), White Polyes- (White only), White (Black ter Poly finish for P/N 08662B Navajo Polyester, Black Polyester Poly finish for P/N 066628 only), and Black Teflon CorrosIon-ResIstant Coatings : White Polyester (White Poly finish for P/N 066628 only), Navajo White Polyester, Black Polyester (Black Poly finish for P/N 06662B only), and Black Teflon Footnotes 1 Based on National Fire Prevention and Control Administration Contract No. 7-34660. 2 Based on NFPA.13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3The corrosion-resistant coatings have passed standard corrosion tests required by particu- lar approving agencies. Refer to the approval chart on page 41 b. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on sprinklers with Teflon0 Coating, Polyester Coating, or Poly finishes. labial - Note: Units of measure in parentheses New format replaces page 41 a-d and page 511 a-d, dated may be approximations. February 17, 2000. Refer to technical data page OR1-2 Form No. F081296 for care, installation, and maintenance information. Sprinkler 41 b October 1 • 2000 MICROFASr AND MicrofastHP4 QUICK RESPONSE I PENDENT SPRINKLERS I Approval ctart Temperature y 1 MIcrofast and MIcroftatHpa I Finish Quick Response Pendent Sprinklers' Al X4— Escutcheon (if applicable) Maximum 175 PSI WWP Stqndard Orifice ThreOd She Sprinkler Description I Nom1nl K-1 Overall Lngthl Listings and Apçrovale2 metric' 1 inches I mm UL I ULC FM! 7c NYC3 VdS LP NPT BSP Bass Part No.1! lldenttflcattanl U.S. i/2415mm-0G662BkVKS02 -H -5.6 1 7.91- .3 A2XB3YiA1X.B4YIA2XR2Y1 C14Al2,. 3/4" 20 mm I 6666$ L VK352 p.p 61 I 1 11.5 In7A .B2yl A3X 1 SlY A2X 82?! : 1/2" I - 067658 I VK352 I 8.0 I - i I A2X I A3X I - x i 15mm1 067188k I VX329 I 2.6 I 39 69 I A2X A2X. 62Y I A2X I-69 - I I 4.2hOmml L '11(331 I M-2 A2X06720Q4 A2X I 069326 I VK329 I - 5,6 58 I - - I - ci Maximum 250 PSI WWP Standard 0r111c Thrd She Description INomI9i Factor Overall LngffiI Uallnge NPT BSP Basis Part No.' kl aflonl I 12 u.s.12 I metric1 I Inches mm I UL ULC I FM I NYC" IVdS L.PCB 1/2" 115 mm l 066828 I VK302 1 5.6 I 7,9 I 2.3 I 58 x I , - 5paii Orifice1 1/2" 115 mml 06718B '( 2.8 3.9 I 2.7 I 69 I A2X A2X, 62Y : - Ii 0mm I 069326 I '11(329 - 5.8 I 2.3 I 58 I - - "!. 1 Approved Temperature Ratings A - 135 OF (57 "C), 155 "F (68 °C),175°F(79°C),200°FI (93 "C), and 288 OF (14C) B -135 OF (57 "C) 155 OF (68' "C), 175 "F (19 "C), and 200 "F (93 "C) C - 155 OF (68 "C) Approved Finishes 1 - Brass and Chrome-Enloy 2- Brass, Briojit Brass, Chrome- Polyester Poly finish' for PIN 06682B only)1 Navalo Black I Black , (Black Poly finisli for P/N 066628 only), and 3-Brass, Bright Brass. Chrome-Enloy WhitePolvesterl (WhIte Poly finish7 for P/N 066628 only), Naval.p White1 I t'olyester7 and Black Polyester (Black PO4 finish' for P/N 066628 o04) j4 - Brass, Chrome-Enloy, White Poly finish7, and Black Poly finis hp Approved Escutcheons IX - Standard surface-mounted escutcheon or the I Viking Microlast Model F-i AdjustableEs- I cutcheon'° m - Standard surface-mounted escutcheon or I the Viking Microfast Model F-i Adjustable Escutcheon'° or recessed with the VIig MknaikM&ieIE-1 ReCSSOCIES on z - Standard surface-mounted escutcheon or the Viking Microtast Model F-i Adjustable Es-cutcheon10 or recessed part number is shown. For complete part number, refer to Viking's current price schedule. 2Thjs table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Accepted for use City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. The sprinkler orifice is bushed. 5 Refer to the "Sprinkler Accessories" section of the Viking Engineering and Design Data book for technical data on approved escutcheons and other accessories. ° UL, ULC, and C-UL Ustings and NYC Approvals limited to Light-Hazard Occupancies with hydraulically calculated wet systems. 7 UL, ULC, and C-UL Usted and NYC Approved as corrosion resistant. °Metric K-Factor stiown is for use when pressure is measured in kPa. When pressure is measured In BAR, multiply the metric K-Factor shown by 10.0. FM Approved for use in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. '°The Viking Mlcrofast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible ele- ment of the sprinkler to be recessed behind the face of the waU or ceiling. 11Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. 12Sprinkler I .D. Nos. and nominal U.S. K-factors provided in accordance with the 1999 edItion of NFPA 13, Section 3-2.2 and Section 3-2. 3 . Ceiling Opening Size: 2-5/16" (68,7 mm) Minimum, 2-1/2"(63,5 mm) Maximum. (54 mm) aim tti. PAL ___ 1-3/4" LT— ., (44,45 mm) 2-1/8 11 '(34,9 mm) 13/8 (54mm) Minimum Momurn \IF/ 1"(25,4 mm) - - Maximum - - Minimum (44.5 mm) Quick Response Pendent Sprinkler Quick Response Pendent Sprinkler Installed Quick Response Pendent Sprinkler Installed with a Standard 1/8" with the Viking Microfast® Model F-i - Installed with the Viking Micromatic5 (3,1 mm) Surface-Mounted Escutcheon Adjustable Escutcheon Model E-1 Recessed Escutcheon New format replaces page 41 a-d and page 51 a-d, dated February 17, 2000. Refer to technical data page QR1-2 for care, installation, and maintenance Information. Form No. F_081296